11

Hardware-in-the-loop Simulation of a Pumping Station : Design and implementation of a Python-based simulation program / Hardware-in-the-loop-simulering av en Pumpstation : Design och implementering av ett Python-baserat simuleringsprogram

Liang, Katrina January 2022 (has links)
The use of simulation enables testing of a system without the need for a complete physical system, while also having the advantages of lower cost and fewer practical limits compared to field tests. Hardware may be integrated into the simulation loop, such a simulation is defined as a Hardware-in-the-loop (HIL) simulation. The pump is the most energy-consuming part of a pumping station, thus improvement and assessment of the pump controller are two of the main considerations in the development of pumping stations. Nevertheless, the developers do not always have access to a real pumping station to run tests on. A HIL simulator that imitates parts of a pumping station while including a real controller in the simulation is therefore desirable for the development of pump controllers.In this thesis, a mathematical model of a pumping station was built based on the physical features of different components, and a HIL simulation was implemented with the programming language Python, in which a real controller was integrated into the simulation loop. Through a three-hour-long simulation run, the functionality of the simulator has been analyzed, and the simulation accuracy was evaluated by comparing simulated results to real data. The results showed that among the 10 800 simulated data points of the water level, there were \(43\) (\(\approx 0.39\%\)) that had a relative change larger than \(30\%\) or less than \(-30\%\) with respect to the field data. This thesis contributes to the field of Python-based simulation of a pumping station, and serves as a foundation for future improvement for the host company. / Användningen av simulering möjliggör testning av ett system utan ett komplett fysiskt system, till en lägre kostnad och färre praktiska begränsningar jämfört med fälttester. Hårdvara kan integreras i simuleringsloopen, en sådan simulering kallas för en hardware-in-the-loop (HIL) simulering. Pumpen är den mest energikrävande delen i en pumpstation, därför är förbättring och utvärdering av pumpstyrningen två av de viktigaste faktorerna vid utvecklingen av pumpstationer. Dock har utvecklarna inte alltid tillgång till en fysisk pumpstation att köra tester på. En HIL-simulator som imiterar delar av en pumpstation, till vilken en pumpstyrning kan kopplas, är därför önskvärd för utvecklingen av pumpstyrningar.I detta examensarbete konstruerades en matematisk modell av en pumpstation utifrån de fysiska egenskaperna hos olika komponenter. En HIL-simulator var sedan implementerad i programmeringsspråket Python, där en riktig pumpstyrning integrerades i simuleringsloopen. Genom en tre timmar lång körning har simulatorns funktionalitet analyserat, och simuleringsnoggrannheten utvärderades genom att jämföra simulerade resultat med verkliga data. Resultaten visade att \(43\) av de 10 800 (\(\approx 0,39\%\)) simulerade datapunkterna för vattennivån hade en relativ förändring större än \(30\%\) eller mindre än \(-30\%\) med avseende på fältdata. Detta arbete bidrar till området inom Python-baserad simulering av en pumpstation och agerar som en grund för framtida utvecklingar hos värdföretaget.
12

Bräddning av avloppsvatten : Möjlighet till rening för att skydda recipienten / Sewage overflow systems : Possibility of improving quality to protect recipient

Dahlqvist, Marcus, Lind, Hampus January 2023 (has links)
Rapporten handlar om olika reningstekniker vilka kan användas för att behandla avloppsvatten som släpps ut vid bräddning innan det når recipienten. Rapporten beskriver först vad bräddning är och även vilka problem som kan uppstå när orenat vatten släpps ut och vad det eventuellt kan innehålla. Flera potentiella reningstekniker lyfts fram och analyseras för att sedan kunna användas i en multikriterieanalys med kriterier såsom miljöpåverkan, passivitet och kapacitet. Olika viktningar används för att bestämma hur bra de olika reningsteknikerna är med olika fokus. / The report focuses on various purification techniques that can be used to treat wastewater discharged during overflow events before it reaches the receiving water body. The report begins by describing what overflow events are and the potential issues that can arise when untreated water is discharged, including possible contaminants. Several potential purification techniques are highlighted and analyzed, intending to be utilized in a multicriteria analysis with criteria such as environmental impact, efficiency, and capacity. Different weightings are employed to determine the performance of the various purification techniques based on different focal points.
13

Zdravotně technické instalace ve výškovém domě / Sanitation installations in a high building

Slaninová, Anna January 2013 (has links)
My final thesis "Health technical installations in high-rise building" is developed in the form of a project presentation containing all requirements according to applicable regulations for presenting a building construction plan. The design documents a tall building with twenty floors above ground with 3 underground floors handled by distribution of plumbing, and water system, including drainage systems. This property consists of underground garages, offices, restaurants and apartments. Documentation includes projects of connections - water, sewer, individual floor plans, sections, and axonometric diagrams. The thesis is developed by including specialty architectural design and includes the seminar work “Drinking water supply for high-rise building.”
14

Den intelligenta pumpstationen -Optimering av energiförbrukningoch utveckling avautomatiseringsfunktion förfelhantering / The intelligent pump station –Optimization of energyconsumption and development ofautomation function for errormanagement

Karlsson, Kristoffer January 2017 (has links)
Detta arbete har undersökt möjligheten att via styrsystemet för en avloppspump-station optimera energiförbrukningen av pumpar och med styrfunktioner förenkla driftunderhållet av stationen.För att undersöka energiförbrukningen har en teoretisk modell av en pumpstation gjorts där energitester för tre olika reglermetoder simulerats. Två av metoderna var start/stopp-styrning och en P-regulator som vanligen används i pumpstationer. Den tredje metoden var en Fuzzy-regulator som med hänsyn till nivån och nivåför-ändring reglerar varvtalet på pumpen.Resultatet från energitesterna visade att start/stopp-styrning förbrukade mest energi och att Fuzzy-regulatorn påvisade bäst egenskaper för att optimera energi-förbrukningen. Fuzzy-regulatorns energiförbrukning var mindre vid merparten av testerna jämfört med P-regulatorn. Fuzzy-regulatorn påvisade bäst egenskaper då inflödet var lågt relativt pumpens kapacitet och då bottenarean på sumpen var mindre.Vid undersökning av nya styrfunktioner har intervjuer av driftchefer utförts för att få en bild av problematiken som kan uppstå i en pumpstation. De styrfunktioner som utvecklats hade syftet att minska antalet förstoppade pumpar då detta var största problematiken. / This paper has investigated the possibility of optimizing the power consumption of pumps through the control system for a wastewater pumping stations. Further-more, the possibilities of developing new control functions has been investigated, with the purpose to simplify the operation maintenance of the station. To investigate energy consumption, a theoretical model of a pumping station has been made where energy tests for three different control methods have been per-formed. Two of the methods studied were on/off control and a P controller which are commonly used in pump stations. The third method was a Fuzzy controller which, with regard to the level and level change, regulates the speed of the pump.The results from the energy tests showed that on/off control consumed most en-ergy and the Fuzzy controller demonstrated best features to optimize energy con-sumption. The Fuzzy controller’s energy consumption was less in most of the tests compared with the P controller. The Fuzzy controller showed the best properties when the inflow was low relative to the pump’s capacity and the bottom area of the sump was smaller.When investigating new control functions, interviews with management executives has been made to get a picture of the problems that may occur in a pump station. The control functions developed had the purpose of reducing the number of clogged pumps as this was the biggest problem.

Page generated in 0.0948 seconds