• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 205
  • 6
  • 2
  • Tagged with
  • 217
  • 217
  • 125
  • 124
  • 60
  • 42
  • 38
  • 38
  • 36
  • 33
  • 33
  • 32
  • 29
  • 27
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Avaliação analítica integrada de PM1 e nanopartículas atmosféricas

Schneider, Ismael Luís January 2016 (has links)
As nanopartículas atmosféricas podem causar diversos efeitos à saúde já que durante a inalação podem penetrar mais profundamente no sistema respiratório humano, atingindo inclusive os alvéolos e a corrente sanguínea, e, desta forma, aumentar os efeitos toxicológicos prejudiciais. Estas partículas podem ser emitidas diretamente para a atmosfera (partículas primárias) ou ser formadas por conversão gás-partícula (partículas secundárias). Durante a última década, estudos têm sido realizados para uma melhor compreensão sobre as concentrações de nanopartículas, avaliando sua emissão, formação, dispersão, exposição e os efeitos à saúde. No entanto, poucos estudos foram realizados no Brasil e desta forma ainda há pouca informação em relação a esta temática. A Região Metropolitana de Porto Alegre - RMPA (Brasil) possui forte tráfego veicular, cerca de 1,8 milhões de veículos e, apesar das fontes móveis impactarem fortemente a qualidade do ar nesta região e ser a principal fonte de nanopartículas, não há estudos que avaliem em profundidade os níveis deste importante poluente ambiental. Desta forma, no presente estudo foram avaliadas as concentrações de nanopartículas em diferentes pontos da RMPA. Além disso, foram avaliadas as concentrações ambientais de partículas <1 μm (MP1) e metais associados, bem como foram identificadas e quantificadas as contribuições de fontes utilizando o modelo receptor Positive Matrix Factorization (PMF). Em adição, foi realizada uma análise das assinaturas espectrais no infravermelho de nitro-hidrocarbonetos policíclicos aromáticos (nitro-HPAs) associados ao MP1. Este grupo de compostos orgânicos possui uma ampla distribuição no ambiente e, por possuírem propriedades mutagênicas e carcinogênicas, seus riscos ambientais foram calculados. Desta forma, considerando os resultados obtidos, verificou-se uma forte contribuição antropogênica dos poluentes avaliados na RMPA. Esta degradação da qualidade do ar está em geral associada ao tráfego veicular, especialmente no que se refere aos níveis de nanopartículas e nitro-HPAs associados ao MP1. Além disso, as emissões industriais, a queima de carvão, biomassa e óleo combustível, bem como a queima de combustíveis veiculares apresentaram forte influência nos níveis de metais observados em MP1. / Atmospheric nanoparticles can cause health effects, as during inhalation penetrate more deeply into the human respiratory system, including the alveoli and reaching the bloodstream, and thereby increase the damaging toxicological effects. These particles can be emitted directly to the atmosphere (primary particles) or be formed by gas-to-particle conversion (secondary particle). Over the last decade, studies have been conducted for a better understanding of the nanoparticles, assessing the emission, formation, dispersion, exposure and health effects. However, few studies have been conducted in Brazil and thus there is little information regarding this subject. The Metropolitan Area of Porto Alegre - MAPA (Brazil) has a strong vehicular traffic, about 1.8 million vehicles and, despite mobile sources strongly impact the air quality in this region and be the main source of nanoparticles, there are no studies that evaluate in depth the levels of this important environmental pollutant. Thus, considering this knowledge gap, the present study evaluated the nanoparticle concentrations in different sites of the MAPA. In addition, environmental concentrations of particles <1 μm (MP1) and associated metals were evaluated and the sources were identified and quantified using the receptor model Positive Matrix Factorization (PMF). In addition, an analysis of the infrared spectral signatures of nitro polycyclic aromatic hydrocarbons (nitro-PAHs) associated with PM1 was performed. This group of organic compounds has a wide distribution in the environment, and because they have mutagenic and carcinogenic properties, their environmental risks were calculated. Thus, considering the obtained results, a strong anthropogenic contribution of the evaluated pollutants in the MAPA was observed. This degradation of the air quality in general is associated with vehicular traffic, especially regarding the levels of nanoparticles and nitro-PAHs associated with PM1. In addition, industrial emissions, coal, biomass and fuel oil combustion, as well as vehicle fuels combustion had a strong influence on the metal levels observed in PM1.
152

Obtenção do IQA para avaliação da qualidade da água em rios dos municípios de Abaetetuba e Barcarena (PA) / Obtaining the WQI to assess water quality in rivers and the towns of Abaetetuba Barcarena (PA)

MEDEIROS, Adaelson Campelo January 2012 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-03-08T21:37:46Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_ObtencaoIQAAvaliacao.pdf: 2862643 bytes, checksum: 6d2f60e507d56c2ffad77dd75e2f2e4e (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-03-13T13:44:44Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_ObtencaoIQAAvaliacao.pdf: 2862643 bytes, checksum: 6d2f60e507d56c2ffad77dd75e2f2e4e (MD5) / Made available in DSpace on 2013-03-13T13:44:44Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_ObtencaoIQAAvaliacao.pdf: 2862643 bytes, checksum: 6d2f60e507d56c2ffad77dd75e2f2e4e (MD5) Previous issue date: 2012 / Este trabalho teve como finalidade a avaliação da qualidade das águas de dois rios amazônicos denominados de Arapiranga e Murucupi localizados nos municípios de Abaetetuba e Barcarena respectivamente, no Estado do Pará. Para esta avaliação, utilizou-se como principal ferramenta o Índice de Qualidade das Águas (IQA) calculado a partir de nove (09) variáveis analisadas. Os cálculos do IQA foram realizados de acordo com os critérios da CETESB-SP, adaptados da National Foundation Sanitation-EUA. Este estudo foi realizado no ano de 2009 e contemplou quatro campanhas de amostragem trimentrais envolvendo o período chuvoso e seco, sendo as variáveis determinadas em condições de marés baixa-mar e preamar. A partir dos dados das variáveis e IQAs determinados, foi possível realizar algumas comparações sobre a qualidade das águas dos rios estudados e para isso, aplicou-se sobre estes dados, a estatística descritiva, analítica e multivariada. Na estatística descritiva determinaram-se no período chuvoso e no seco os valores de média, desvio padrão, valores máximos e mínimos e coeficiente de variação. Para a verificação da distribuição amostral e nível significância dos dados gerados, realizou-se a partir da estatística analítica os testes de normalidade e de hipóteses respectivamente, comparando-se os dados das variáveis e dos IQAs do período chuvoso e do seco. A análise multivariada proporcionou uma melhor avaliação sobre a qualidade das águas destes dois rios através da análise de grupos. O rio Arapiranga apresentou condições de qualidade regular e boa, registrando-se valores médios dos IQAs no período chuvoso de 48±3,7 e 51±5,6 na maré baixa-mar e preamar respectivamente, no período seco esses valores foram de 48±4,6 (maré baixa-mar) e 55±5,7 (maré preamar). A partir dos valores dos IQAs determinados no rio Murucupi, observou-se condições de qualidade ruim, regular e boa nessas águas, sendo que, os valores médios obtidos no período chuvoso foram de 44±9,4 e 51±10,3 (maré baixa-mar e preamar), já no período seco esses valores foram de 51±8,3 na maré baixa-mar e de 52±8,6 na preamar. As ferramentas de avaliação utilizadas neste estudo proporcionaram uma boa visualização sobre a qualidade das águas nos dois rios, observando-se no geral, que houve diferença signifitiva de qualidade para essas águas em relação à comparação entre o período chuvoso e o seco. Percebe-se que o rio localizado no município de Barcarena/PA, sofre maior influência antropogênica em decorrência da maior área urbana em seu entorno, já no outro rio no município de Abaetetuba/PA, essa influência é menor. / This study was aimed at assessing the quality of the waters of two rivers called Amazon Arapiranga Murucupi and the municipalities of Abaetetuba and Barcarena respectively, in the State of Pará. For this evaluation, was used as the main tool of the Water Quality Index (WQI) calculated from nine (09) variables. The WQI calculations were performed according to the criteria of SP-CETESB adapted National Sanitation Foundation, USA. This study was conducted in 2009 and included four sampling campaigns involving trimentrais the rainy season and dry, and variables in certain conditions of tide low tide and high tide. From the data of variables and WQIs determined, it was possible to make some comparisons on the quality of the rivers studied and it was applied on these data, descriptive statistics, analytical and multivariate. Descriptive statistics were determined during the rainy season and dry values of mean, standard deviation, minimum and maximum values and coefficient of variation. To verify the significance level and sample distribution of the data generated, was held from the statistical analytical tests of normality and hypotheses respectively, comparing the data of variables and WQIs in the rainy season and dry. The multivariate analysis provided a better assessment of water quality of these two rivers through the analysis of groups. The river conditions presented Arapiranga regular and good quality, recording average values of the rainy season WQIs 48 ± 3.7 and 51 ± 5.6 in the ebb-tide and high tide respectively during the dry season, these values were 48 ± 4.6 (low tide and high) and 55 ± 5.7 (low tide and high). From the values of certain WQIs Murucupi the river, we observed conditions of poor quality, regular and good in those waters, and the average values during the rainy season were 44 ± 9.4 and 51 ± 10.3 (low tide and high), in the dry period, these values were 51 ± 8.3 at low tide and 52 ± 8.6 at high tide.The assessment tools used in this study provided a good view on the quality of water in both rivers, observing in general, that there were differences signifitiva quality for these waters with respect to the comparison between the rainy and dry. It is noticed that the river located in Barcarena / PA, undergoes major anthropogenic influence due to the largest urban area in its vicinity, as in other river in the city of Abaetetuba / PA, this influence is less.
153

Estudo numérico do impacto da frota veicular na qualidade do ar na região metropolitana de Porto Alegre / Numerical study of the vehicle fleet impact in air quality at the greater Porto Alegre

Chovert, Angel Domínguez, Chovert, Angel Domínguez 18 February 2016 (has links)
Submitted by Maria Beatriz Vieira (mbeatriz.vieira@gmail.com) on 2017-05-29T15:40:50Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) dissertacao_angel_dominguez_chovert.pdf: 4326730 bytes, checksum: f0ab18024d41a455506084caf36f3787 (MD5) / Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2017-05-29T21:23:14Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) dissertacao_angel_dominguez_chovert.pdf: 4326730 bytes, checksum: f0ab18024d41a455506084caf36f3787 (MD5) / Made available in DSpace on 2017-05-29T21:23:14Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) dissertacao_angel_dominguez_chovert.pdf: 4326730 bytes, checksum: f0ab18024d41a455506084caf36f3787 (MD5) Previous issue date: 2016-02-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Vários setores econômicos do Brasil passaram por um grande processo de desenvolvimento e transformação nos últimos anos, mesmo com a atual frenagem da economia nacional. Como consequência direta desse desenvolvimento, se produz, em muitos dos casos, um aumento da contaminação ambiental. Um dos setores de maior crescimento e que influi fortemente nesta contaminação, especificamente na poluição atmosférica, é o de transporte; apesar disso os estudos realizados no Brasil são insuficientes para conhecer o comportamento futuro da poluição associada este setor, o que permitiria tomar medidas de controle e mitigação importantes no contexto da gestão ambiental por parte dos tomadores de decisão. Neste trabalho se faz um estudo numérico do impacto da evolução da frota veicular na qualidade do ar na Região Metropolitana de Porto Alegre (RMPA). Utilizou-se o sistema de modelagem CCATT-BRAMS (Coupled Aerosol and Tracer Transport model to the Brazilian Development on the Regional Atmospheric Modelling System) para realizar as simulações, e a ferramenta PREP-CHEM-SRC (Preprocessor of trace gas and aerosol emission fields for regional and global atmospheric chemistry models) para obter inventários de emissão que serviram de dados de entrada no modelo. Com a finalidade de complementar a informação global de emissão, criaram-se cenários associados à evolução da frota veicular até o ano de 2030 na região de estudo utilizando a ferramenta LEAP (Long range Energy Alternatives Planning System), com a que se processou informação vinculada com a frota total circulante e novos licenciamentos na RMPA, além dos fatores de emissão e intensidade de uso das diferentes categorias de veículos. Os resultados mostraram uma diminuição das emissões veiculares totais em 2030 com relação ao ano base 2009, muito por conta de mudanças de tecnologia e o estabelecimento de políticas de regulamentação da emissão associada à combustão incompleta dos veículos brasileiros. Para as emissões de CO associadas à estimativa pessimista da frota a diminuição no período mencionado foi de 4,7 %, já para os NOx e os HCNM a diminuição foi de 61,3 % e 34,6 % respectivamente. Essa diminuição nas emissões provocou, segundo o resultado da comparação entre as simulações realizadas, uma diminuição nas concentrações médias dos NOx estimadas para o ano de 2030 (diminuição que varia entre 40 % e 60 % em relação ao ano base) e um aumento das concentrações médias de O3 no horário da noite e pela manhã (de até 40 %) assim como uma diminuição para essa espécie no horário da tarde e começo da noite (de até 20 %). Foi possível observar também a influência da diminuição das emissões na RMPA sobre as concentrações registradas de O3 e dos NOx nas áreas circunvizinhas, evidenciando o forte impacto dos grandes centros urbanos em municípios e áreas rurais vizinhas. / Many economic sectors in Brazil have developed and transformed in recent years, which has now diminished by the unfavorable situation in the economy. In most cases, the economic growing affects the environmental pollution. One of the sectors where more changes have occurred and that greatly influences pollution, specifically air pollution, is transport; despite that, studies in Brazil are insufficient to estimate the pollution tendency associated with this sector, important to mitigation police. This investigation aim to the study of the vehicle fleet impact on air quality in the Greater Porto Alegre (GPA). The models-system CCATT-BRAMS (Coupled Aerosol and Tracer Transport model to the Brazilian Development on the Regional Atmospheric Modeling System) was used to perform the simulations and the PREP-CHEM-SRC (Preprocessor of tool trace gas and aerosol emission fields for regional and the global atmospheric chemistry models) for emission inventories that serve as inputs to the model. The base year for analysis was 2009 and the scenarios are constructed until 2030. In order to complement global emissions information, they were created pollution emission scenarios associated with the evolution of the vehicle fleet in the study region using linked information such as total current fleet and new licenses in GPA, in addition to emission factors and intensity of use of different vehicles. The results show a decrease in emissions of CO, NMHC and NOx in 2030 compared to 2009 base year, related to the vehicular activity. This decrease was caused mainly by the renewal of technology fleet and the implementation of emission control programs created by the government. This reduction in the emissions caused a decreasing in the NOx average concentrations estimated for 2030 (decreasing of between 40 % and 60 % in relation to the base year) and an increasing in the O3 average concentrations of at night and morning (up to 40 %) and decline of this species in afternoon and early evening (up to 20 %). It was also possible to observe the influence of reduced emissions in GPA on levels of O3 and NOx in the neighboring areas, demonstrating the strong impact of major urban centers in the towns and surrounding areas.
154

Avaliação das condições ambientais e de trabalho em salas cirúrgicas e de necropsia - estudos de casos em hospitais públicos e IMLs da região metropolitana do Rio de Janeiro / Environmental and work conditions assessment - study cases in public hospitals and IMl'S of the metropolitan region of Rio de Janeiro

Sheila de Lira Franklin 04 August 2011 (has links)
A qualidade do ar é um importante indicador de saúde ambiental, sendo o seu monitoramento contínuo necessário. Apesar da relevância do tema, há muitos países em que os limites de exposição para agentes biológicos ainda não foram estabelecidos ou foram definidos de forma inadequada, podendo comprometer a qualidade ambiental. Os ambientes hospitalares, assim como as salas de necropsia podem apresentar problemas de contaminação do ar por agentes microbiológicos, necessitando de monitoramento contínuo a fim de evitar a ocorrência de doenças nos trabalhadores e na população em geral. Este estudo realizou a avaliação microbiológica do ar em hospitais públicos e IMLs da região metropolitana do Rio de Janeiro em salas cirúrgicas e de necropsia. A pesquisa exploratória e descritiva baseou-se em levantamento bibliográfico e investigação de campo, através de estudos de casos. Os dados foram obtidos por meio de entrevistas e observação direta nos locais de trabalho, onde foram realizadas as avaliações microbiológicas do ar. As variações em salas cirúrgicas para bactérias e fungos foram respectivamente de 14,99 ufc/m3 88,29 ufc/m3 e de 45,93 ufc/m3 - 742,09 ufc/m3. Já nas salas de necropsia os valores para bactérias e fungos variaram respectivamente de 18,96 ufc/m3 54,9 ufc/m3 e de 144,87 ufc/m3 - 1152,01 ufc/m3. Foram identificados tanto no ambiente cirúrgico como nas salas de necropsia a presença dos seguintes fungos: Aspergillus sp., Neurospora sp., Penicillium sp., Fusarium sp., Cladosporium sp., Curvularia sp., e Trichoderma sp. Já em relação às bactérias foram identificadas as presenças de Staphilococcus sp., Streptococcus sp. e Micrococcus sp. Foram traçadas recomendações para melhoria da qualidade ambiental e do ar. Os resultados indicaram que os valores são elevados quando comparados com as recomendações das normas internacionais. Foram encontrados valores inferiores aos sugeridos pela CP n. 109 da ANVISA. A presença de microrganismos patogênicos sugere adoção de medidas de controle ambiental. O estudo apontou a necessidade urgente do estabelecimento de valores de referência para ambientes hospitalares no Brasil a fim de garantir condições seguras que não venham a comprometer a saúde dos pacientes e profissionais de saúde envolvidos. / The indoor air quality is an important environmental health indicator and yours continuous monitoring is necessary. Its depends on, among other factors, of the biological agents exposure limits fixing. Despite this topic relevance, in many countries, the biological exposure limits still dont exist or were inadequately defined. What can compromise the environmental quality. The hospital environments just as the necropsies rooms can have indoor air contamination problems caused by microbiological agents and needs to have continuous monitoring to avoid the occurrence of diseases in the workers and in the overall population. This study realized a microbiological indoor air assessment at surgical rooms of three public hospitals and autopsies rooms of two IMLs located in the city of Rio de Janeiro. The study was descriptive and exploratory based on bibliographic review and camping research though study cases. Data were obtained from interviews with the health workers and cleaning team and direct observation at the selected workplaces. The fungal and bacteria variation in surgical room and autopsy room were respectively of 14,99 88,29 ufc/m3 and 45,93 ufc/m3 742,09 ufc/m3. Were detected in the surgical rooms and necropsy rooms the fungal genera: Aspergillus sp., Neurospora sp., Penicillium sp., Fusarium sp., Cladosporium sp., Curvularia sp., e Trichoderma sp. and bacterial genera: Staphilococcus sp., Streptococcus sp. and Micrococcus sp. Were traced recommendations to improve environment and air quality. The results indicate that the limits can be considered exceed when compared with those proposed by the international organisms. Were identified some values lower than 50 ufc/m3 proposed by the CP n. 109 ANVISA. The presence of pathogenic microorganisms suggest the need of environmental control measures. That indicate the values actually used as reference in Brazil must been revised considering the environments specificities and the urge to create a specific legislation for hospital environments that guarantee security conditions and do not comes to compromise the health and well being of the patients and health professionals involved
155

Avaliação da qualidade do ar em unidades de terapia intensiva e sua correlação com o ambiente externo e a saúde dos trabalhadores / Evaluation of intensive care units air quality and its correlation with both external environment and workers\' health

Marilia Jukemura Miyagusko 12 September 2008 (has links)
Nos locais de trabalho, a qualidade do ar pode interferir na performance dos trabalhadores e no risco de doenças. Sabe-se que a qualidade do ar interior pode ser afetada pelos poluentes gerados no ambiente exterior. Nos hospitais, estes temas têm sido insuficientemente analisados e nas unidades de terapia intensiva eles ainda não foram investigados. Os objetivos deste estudo foram analisar a correlação entre os níveis de poluentes medidos dentro e fora das unidades de terapia intensiva e investigar a associação entre a qualidade do ar nas unidades e a saúde dos trabalhadores. Oito unidades de terapia intensiva localizadas em quatro hospitais diferentes foram incluídas neste estudo. Níveis de poluentes, temperatura e umidade relativa do ar foram medidos dentro e fora das unidades, simultaneamente, durante períodos de sete dias específicos para cada unidade. Monitores automáticos foram usados para o monitoramento do MP2,5, enquanto monitores passivos foram usados para as medidas de NO2 e O3. Um questionário de sintomas foi aplicado a cada trabalhador das unidades de terapia intensiva que concordou em participar do estudo. Para testar diferenças nos poluentes e nas variáveis meteorológicas em cada unidade (dentro e fora) adotamos o teste t de Student ou o teste U de Mann-Whitney. Para testar diferenças entre a unidades nós adotamos o teste de análise de variância para amostras independentes (ANOVA) e o teste HSD-Tukey, quando necessário. Adotamos os coeficientes de correlação de Pearson ou de Spearman para avaliar correlações entre as medidas interiores e exteriores em cada unidade. Para as associações entre os sintomas e o local de trabalho nós adotamos o teste de qui-quadrado de Pearson ou o teste exato de Fisher. A unidade 1 apresentou a maior média interior de MP2,5 (33,9 g/m3; Desvio Padrão - DP = 44,2), estatisticamente diferente das demais unidades (p < 0,05). Além disso, este valor foi quase 16 vezes maior do que a média de MP2,5 observada na unidade 6 (2,1 g/m3; DP = 3,4), a menos poluída. Em cinco unidades, as medidas interiores e exteriores de MP2,5 apresentaram correlações estatisticamente significativas (p < 0,05). Tanto para o NO2 quanto para o O3, os valores exteriores foram maiores do que os interiores e não ouve correlação entre eles. Entre os 18 sintomas investigados, dores nas costas, ombros e pescoço (65%), cefaléia (65%), cansaço e fadiga (62%), tensão e irritabilidade (58%), coriza (51%), espirros (45%), vista cansada (44%), olhos secos (42%), dor de garganta (38%), dificuldade de concentração (35%) e tosse (27%) foram os mais relatados. As freqüências de sintomas foram semelhantes em todas as unidades. Não foram observadas associações entre a qualidade do ar interior e os sintomas relatados. Estes resultados mostraram que o isolamento entre os ambientes internos e externos através dos sistemas de ar condicionado pode variar permitindo altas concentrações de partículas finas interiormente. Além disso, a falta de correlações entre os gases dentro e fora das unidades indica a presença de fontes interiores para os dois poluentes. Potenciais associações entre a qualidade do ar nas unidades e sintomas de doenças requerem investigações adicionais / In work facilities, air quality can interfere in workers performance and in diseases´ risk. It is well known that indoor air quality can be affected by pollutants generated outdoor. In hospitals these topics have been insufficiently investigated and in intensive care units they have not been explored yet. The aims of this study were to analyze the correlation between indoor and outdoor levels of air pollutants in intensive care units and investigating the association between indoor air quality and workers health. Eight intensive care units located in four different hospitals were included in this study. Indoor and outdoor levels of air pollutants, temperature and relative humidity were measured simultaneously in each unit along unit-specific seven-day periods. Automatic monitors were used to measure PM2.5 while passive samplers were adopted to measure both NO2 and O3. A questionnaire of symptom was applied to each intensive care unit worker that agreed in participating of the study. In order to test differences in pollutants and weather variables measurements intra-units (inside and outside) we adopted the Student t test or Mann-Whitney U test. To test differences inter-units we adopted one-way analysis of variance for independent samples (ANOVA) and the Tukeys Honestly Significantly Different post-hoc test when necessary. We adopted Pearson correlation coefficients or Spearman correlation coefficients to investigate correlations between indoor and outdoor measures. For associations between symptoms and place of work we adopted qui-square test or Fishers exact test. Unit 1 presented the highest indoor PM2.5 mean (33.9 g/m3; Standard Deviation-SD = 44.2) and it was statistically different from all other indoor measures (p < 0.05). Also, it was almost sixteen fold higher than indoor PM2.5 mean in unit 6 (2.1 g/m3; SD = 3.4), the cleanest one. In five units, indoor and outdoor levels of PM2,5 presented statistically significant correlations (p < 0.05). For both NO2 and O3, outside values were higher than those measured inside and there were no correlations between indoor and outdoor measures. From 18 investigated symptoms, pain in back, shoulders or neck (65%), headache (65%), tiredness or fatigue (62%), tension and irritability (58%), runny nose (51%), sneezing (45%), eyestrain (44%), dry eyes (42%), sore and dry throat (38%), difficult of concentrating (35%) and cough (27%) were the most reported. Frequency of symptoms were similar in all units. There were not associations between indoor air quality and reported symptoms. These results showed that isolation between indoor and outdoor environments through air conditioning systems may vary allowing high indoor concentrations of fine particles. Moreover, the lack of correlation between indoor and outdoor gaseous pollutants indicates the presence of indoor sources of both pollutants. Potential associations between indoor air quality and disease symptoms require additional investigation
156

Abastecimento de água para consumo humano na área urbana de São Luís: onde está a qualidade? / Water supply for human consumption in the urban area of São Luís: where is the quality?

Mendes, Djenane Coimbra Teixeira 18 December 2008 (has links)
Submitted by Rosivalda Pereira (mrs.pereira@ufma.br) on 2017-06-13T20:54:23Z No. of bitstreams: 1 DjenaneMendes.pdf: 8086741 bytes, checksum: b27505ebd584f5dfb679975eb7d53547 (MD5) / Made available in DSpace on 2017-06-13T20:54:23Z (GMT). No. of bitstreams: 1 DjenaneMendes.pdf: 8086741 bytes, checksum: b27505ebd584f5dfb679975eb7d53547 (MD5) Previous issue date: 2008-12-18 / The public supplying in terms of amount and quality has been a constant concern of the humanity, due to scarcity of the water and deterioration of the sources for the launching of effluent and residues, becoming an important factor in the transmission of diseases. During the drinking waters distribution, the quality of this can suffer a series from alterations, then after the exit of the treatment, that can compromise the standards of potabilidade demanded by law nº 518/04, when this arrives at the tap of the user and thus, if differentiating of the quality of the water that leaves the treatment station. In this study, it was looked to evaluate the quality of the water for human consumption of the urban area of São Luis, supplied for the systems of supplying, being recommended measured that they support the public administration of the water resources, of the environment and action of health, education and social mobilization aiming at the access to the water of healthful quality for the population. They had been collected and analyzed water samples of human consumption in the net of distribution in the 195 quarters of the urban area of São Luis, as well as the survey and mapping of the notifications of water-borne diseases propagation: diarrhea and hepatitis, in 07 quarters of the urban area, with bigger occurrence of cases, where it was evaluated correlation with the results of the water samples is of the standards in these quarters and the pluviometric precipitation as increase of incidence of cases. The significance was made through statistical test, which resulted in the relation of increase of the cases of diarrhea in the quarters with bigger occurrence in the rainy and insignificant period for hepatitis cases, illness this that it suggests to have relation with the lack of basic sanitation that if aggravates with the lack of information of the forms of infects. It was carried through still, inspection in the 04 systems of water supply of São Luis, to evaluate the conditions of the installations and process of treatment and distribution of the consumed water. The gotten results of the water samples in accordance with meet in disagreement with law nº 518/04, that it deals with the standards of potabilidade, as well as innumerable conformity found during the inspections in the systems, not pointing its consequences and which had recommendations with respect to corrective measures, the current law and the good norms of practical in the water supply. It was concluded that with the current treatment of the water supplied for the systems, the population of São Luis is displayed to the risk to contract illnesses and other aggravation to the health, having to be taken measured possible to minimize or to solve the problematic one of the distribution of the water, for however displayed. / O abastecimento público em termos de quantidade e qualidade tem sido uma preocupação constante da humanidade, devido à escassez da água e deterioração dos mananciais pelo lançamento de efluentes e resíduos, tornando-se um fator importante na transmissão de enfermidades. Durante a distribuição de água potável, a qualidade desta pode sofrer uma série de alterações, logo após a saída do tratamento, que podem comprometer os padrões de potabilidade exigidos pela Portaria nº 518/04, quando esta chega à torneira do usuário e assim, se diferenciando da qualidade da água que deixa a estação de tratamento. Neste estudo, procurou-se avaliar a qualidade da água para consumo humano da área urbana de São Luís, fornecida pelos sistemas de abastecimento, recomendando medidas que apóiem a gestão pública dos recursos hídricos, do meio ambiente e ações de saúde, educação e mobilização social visando o acesso à água de qualidade saudável para a população. Foram coletadas e analisadas amostras de água de consumo humano na rede de distribuição dos 195 bairros que compõem a área urbana de São Luis, assim como o levantamento e mapeamento das notificações de doenças de veiculação hídrica: diarréia aguda e hepatite A, em 07 bairros da área urbana, com maior ocorrência de casos, onde se avaliou a correlação com os resultados das amostras de água fora dos padrões nesses bairros e a precipitação pluviométrica como aumento de incidência de casos. A significância foi feita através de teste estatístico, o qual resultou na relação de aumento dos casos de diarréia nos bairros com maior ocorrência no período chuvoso e insignificante para casos de hepatite A, doença esta que sugere ter relação com a falta de saneamento básico que se agrava com a falta de informação das formas de contágio. Foi realizada ainda, inspeção nos 04 sistemas de abastecimento de água de São Luis, para avaliar as condições das instalações e processo de tratamento e distribuição da água consumida. Os resultados obtidos das amostras de água encontram-se em desacordo com a Portaria MS nº 518/04, que trata dos padrões de potabilidade, assim como inúmeras não conformidades encontradas durante as inspeções nos sistemas, apontando as suas conseqüências e devidas recomendações para medidas corretivas, de acordo com a legislação vigente e as normas de boas práticas no abastecimento de água. Concluiu-se que com o atual tratamento da água fornecida pelos sistemas, a população de São Luís está exposta ao risco de contrair doenças e outros agravos à saúde, devendo ser tomadas medidas cabíveis para minimizar ou solucionar a problemática da distribuição da água, por ora exposto.
157

Risco tecnológico: uma análise do porto de Vila do Conde como área potencial de ameaça ao vazamento de óleo para comunidades em situação de vulnerabilidade

RODRIGUES, José Edilson Cardoso January 2008 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-03-19T12:26:12Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_RiscoTecnologicoAnalise.pdf: 6586712 bytes, checksum: 367c5e5c2325654f62c9ff44fc29cd88 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-06-05T14:54:10Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_RiscoTecnologicoAnalise.pdf: 6586712 bytes, checksum: 367c5e5c2325654f62c9ff44fc29cd88 (MD5) / Made available in DSpace on 2014-06-05T14:54:10Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_RiscoTecnologicoAnalise.pdf: 6586712 bytes, checksum: 367c5e5c2325654f62c9ff44fc29cd88 (MD5) Previous issue date: 2008 / O presente trabalho foi realizado em Vila do Conde, município de Barcarena que faz parte da mesorregião de Belém do Pará, com objetivo de estudar o risco de natureza tecnológica relacionado ao vazamento de óleo, apontando as reais situações de ameaça e a vulnerabilidade da população local. A metodologia baseou-se em três etapas: levantamento bibliográfico sobre o conceito de risco tecnológico; trabalho de campo para a identificação e caracterização das áreas de ameaça na zona portuária e da área de Vulnerabilidade na Vila do Conde através de visitas técnicas, entrevistas, aplicação de questionários, para o levantamento socioeconômico, observações e registros fotográficos; e por fim levantamento cartográfico e utilização de imagens de satélite IKONOS para delimitação das áreas de ameaça no porto, setorização da Vila do Conde e para a confecção de mapas temáticos. Na zona portuária de Vila do Conde identificamos como principais áreas de ameaça ao vazamento: Área de atracação, onde a prática de acostagem, carga, descarga e abastecimento de navios e balsas com óleo combustível é constante, apresentando nível de ameaça que vai de muito a extremamente provável de ocorrer; Área de acesso, delimitada pela ponte por onde percorre os dutos, apresentando nível de ameaça como provável de ocorrer vazamento e a Área de estocagem, onde concentra os tanques de armazenamento e plataformas de abastecimento apresentando nível de ameaça que vai do provável a muito provável de ocorrer vazamento. Na Vila do Conde a vulnerabilidade social apontou que a população do setor rio, na maioria pescadores, apresenta maior grau de vulnerabilidade, seguido pelos moradores do setor praia, como donos de barracas, que apresentam médio grau de vulnerabilidade, e com baixo grau de vulnerabilidade estão os moradores do setor terra firme. Portanto, um sinistro com óleo acarretará uma reação que ira se difundir em toda a Vila, interrompendo os principais fluxos de troca entre os grupos e suas respectivas atividades. / The present work was accomplished at Conde’s Village, municipal district of Barcarena in Pará State, with objective of studying the technological hazards related to the oil leak, aiming the real menace situations and the vulnerability of the local population. The methodology based on three stages: bibliographical rising on the concept of technological risk; field work for the Identification and characterization of the menace areas in the port zone and of the area of vulnerability in Conde's Village through technical visits, interviews, application of questionnaires, observations and photographic registrations; and finally cartographic rising and use of satellite images IKONOS for delimitation of the menace areas in the port, setorization of Conde's Village and for the making of thematic maps. In the port zone of Conde's Village we identified as main menace areas to the leak: moorings area, where the leant against practice, load, discharge and provisioning of ships and rafts with combustible oil are constant, presenting menace level that is going of a lot the extremely probable of happening; Access area, defined by the bridge through where it travels the pipeline, presenting menace level as probable of happening leak and the stock area, where it concentrates the storage tanks and platforms of provisioning presenting menace level that is going of the probable to very probable of happening leak. In Conde's Village the social vulnerability pointed that the population of the section river, in most fishermen, it presents larger vulnerability degree, proceeded by the inhabitants of the section beach, as owners of huts, that present medium vulnerability degree, and with low vulnerability degree they are the inhabitants of the section firm earth. Therefore, a casualty with oil will cart a reaction that it is angered to diffuse at the whole Villa, interrupting the main change flows between the groups and its respective activities.
158

Avaliação da qualidade da água superficial do canal São Joaquim, Belém - PA

PAREDES, Brenda Melise Morbach 15 March 2016 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T12:16:56Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoQualidadeAgua.pdf: 3174249 bytes, checksum: 3d5294b2ef813b708e8edbd6f078d6fd (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-17T14:06:03Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoQualidadeAgua.pdf: 3174249 bytes, checksum: 3d5294b2ef813b708e8edbd6f078d6fd (MD5) / Made available in DSpace on 2017-03-17T14:06:03Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoQualidadeAgua.pdf: 3174249 bytes, checksum: 3d5294b2ef813b708e8edbd6f078d6fd (MD5) Previous issue date: 2016-03-15 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / O processo de urbanização e a ocupação desordenada de áreas próximas às margens de canais urbanos geram grandes impactos a esses corpos hídricos, sendo um dos principais, o lançamento de efluentes. O canal São Joaquim, Belém-Pa, é considerado o maior canal urbano de Belém, e já sofre com tais impactos, além de ser atingido pela falta de saneamento ambiental, em sua Sub Bacia, tal situação pode ser observada nos resultados obtidos em 12 meses de amostragem ao longo de três pontos, desde sua nascente até sua foz. Esta pesquisa teve como objetivo a análise da qualidade da água do referido Canal, em parâmetros físicos, químicos e biológicos, através do Índice de Qualidade da Água (IQA) e da aplicação de estatística descritiva, analítica e multivariada, sendo possível observar a degradação deste corpo hídrico causada, principalmente, por matéria orgânica, resultado este obtido através das análises de OD, DBO, Nitrogênio Total, Fósforo Total, e Coliformes Termotolerantes. O IQA foi calculado para o Canal, tendo sido obtido o valor igual a 49 classificando-o como de qualidade “aceitável”. Ao realizar uma comparação sazonal entre períodos seco e chuvoso, e condições de maré, através dos testes de hipótese de Mann Whitney e Teste T de Student, foi possível observar que não houve uma variabilidade significativa entre as variáveis, com exceção da Temperatura, a qual apresentou uma variação entre os períodos seco e chuvoso. A análise de variância (ANOVA) foi aplicada para a verificação da similaridade entre os pontos para cada variável analisada. Ao realizar uma avaliação temporal de qualidade da água do canal, entre os anos de 1988; 2002; 2005; 2006; 2011 e 2014. A análise de componente principal propiciou a formação de 3 componentes que juntos explicaram 67,53% das variabilidades dos dados, sendo essas variáveis indicativas de ação antrópica. / The process of urbanization and illegal occupation of urban channel margins nearby areas generate large impacts on these water bodies, the main one being the discharge of effluents. The channel São Joaquim, Belém Pa, is considered the largest urban channel Bethlehem, and already suffers from such impacts, as well as being affected by the lack of sanitation in its Sub Basin, such a situation can be observed in the results obtained in 12 months sampling over three points from its source to its mouth. This study aimed to analyze the said water quality Canal in physical, chemical and biological parameters through the IQA and application of descriptive statistics, analytical and multivariate analysis, being possible to observe the degradation of this water body caused mainly by organic matter, which was obtained through the OD analysis, BOD, total nitrogen, total phosphorus, and thermotolerant coliforms. The Water Quality Index was calculated for the Channel and was obtained the value of 49 classifying it as quality "acceptable." When performing a seasonal comparison between dry periods and wet, and tide conditions, using the Mann Whitney hypothesis tests and test T Student, it was observed that there was significant variability between the variables, except for the temperature, which It showed a variation between the dry and rainy seasons. The analysis of variance (ANOVA) was applied for the verification of similarity between the points for each variable analisada.Ao perform a temporal assessment of water quality of the channel between the years 1988; 2002; 2005; 2006; 2011 and 2014, it was observed that the degradation of the channel has a history of nearly 30 years, a situation confirmed by the analysis of indicator variables of organic matter. The principal component analysis led to the formation of three components that together represented 67.53% of the variability of the data, and these variables explained by the ACP, anthropic action indicative.
159

Análise experimental e numérica da concentração e dinâmica de partículas em sala cirúrgica e quarto de isolamento hospitalar. / Numerical and experimental analysis of particle concentration and dynamics in an operating room and isolation room.

Vilain, Rogério 15 December 2015 (has links)
A presente pesquisa tem como objetivo avaliar a eficiência de diferentes sistemas de ventilação no controle da transmissão aérea de agentes infecciosos em sala cirúrgica e em quarto de isolamento hospitalar. Para isso, foram desenvolvidos estudos experimentais e numéricos a partir de dados gerados em um hospital brasileiro de referência no tratamento de doenças respiratórias. Em uma sala cirúrgica, comparou-se o sistema de climatização existente (sistema de ventilação unidirecional) com um sistema split, adaptado na sala especialmente para este estudo. Em um quarto de isolamento compararam-se diferentes arranjos com ventilação natural (porta e janelas) e/ou mecânica (ventilador axial e unidade de descontaminação - filtro e exaustor). Em ambos os ambientes foram medidos parâmetros ambientais (velocidade do ar, temperatura do ar e intensidade de turbulência) e se realizou um estudo da concentração de partículas, mediante o uso de um gerador de partículas monodisperso. A partir dos dados gerados por meio desses procedimentos experimentais, para a sala cirúrgica, obteve-se o fator de proteção e, para o quarto de isolamento, a probabilidade de infecção utilizando o equacionamento proposto por Wells e Riley, bem como a taxa de decaimento de partículas. Os resultados experimentais subsidiaram a realização de um estudo numérico, que consistiu na avaliação dos campos de velocidade, temperatura e intensidade de turbulência do ar para os diferentes tipos de ventilação estudados e no estudo da dinâmica de partículas nos dois ambientes. Embora o sistema unidirecional seja, teoricamente, mais eficiente no controle das partículas, a metodologia de análise adotada evidenciou ineficiência do sistema na remoção de partículas devido a problemas na instalação e operação. Quanto ao sistema split, o presente estudo, como outros assemelhados, evidenciou a inadequação de seu uso em salas cirúrgicas. No quarto de isolamento a ventilação natural mostrou-se o método mais eficiente para a remoção de partículas e, consequentemente, o que mais reduz o risco de contaminação cruzada, conforme o equacionamento original de Wells-Riley. Para a sala cirúrgica foram obtidos valores experimentais do fator de proteção variando entre 0,10 e 0,52 e de -0,9 a +2,5 na análise numérica. Para o quarto de isolamento foram obtidos experimentalmente riscos de infecção entre 0,25 e 2,65%. Finalizando, este trabalho visa contribuir na proposição de uma metodologia experimental e numérica para a avaliação da dinâmica das partículas e, consequentemente, do risco de infecção por via aérea em ambientes hospitalares. / This research aims to evaluate the efficiency of different ventilation systems to control airborne transmission of infectious agents in a hospital operating room and isolation room. Experimental and numerical studies were carried out based on data generated in a Brazilian reference hospital for the treatment of respiratory diseases. In an operating room, an existing unidirectional air conditioning system (i. e., laminar air flow - LAF) was compared to a split system, adapted in the room especially for this study. In a respiratory isolation room, comparisons were drawn between different arrangements with natural ventilation (door and window) and/or mechanical ventilation (axial fan and decontamination unit - filter plus exhaust fan). In both rooms, environmental parameters (air speed, air temperature and turbulence intensity) were measured, and a study of particle concentration was developed employing a monodisperse aerosol generator. The data generated by these experimental procedures were used to calculate the protection factor for the operating room and the probability of infection for the isolation room, using the equation proposed by Wells and Riley, as well as the rate of particle decay. The experimental results were then used in a numerical study, which included evaluation of the fields of air velocity, temperature and turbulence intensity for different types of ventilation under study, as well as the analysis of particle dynamics in both environments. Although the unidirectional system is theoretically more effective for particle control, the methodology of analysis adopted revealed an inefficiency of this system in removing particles, due to installation and operation problems. Concerning the split system, this research - similarly to analogous studies - emphasizes the inadequacy of its use in operating rooms. In the isolation room, natural ventilation proved the most effective method for removing particles and, consequently, the one which reduces the most the risk of cross-contamination, according to the original Wells-Riley modeling. In the operating room were obtained experimental data for the protection factor ranging from 0.10 to 0.52 and from -0.9 to +2.5 in the numerical analysis. In the isolation room were obtained probabilities of infection between 0.25 and 2.65%. Finally, this work aims to contribute in proposing an experimental and numerical methodology for assessing the dynamics of particles and hence risk of airborne infection in hospital settings.
160

Desenvolvimento de um programa computacional para balanceamento de redes de distribuição de ar. / A development of software to balance air distribution net.

Bendezu Hernández, Luis Miguel Teófanes 25 February 2010 (has links)
O balanceamento de uma rede de distribuição de ar consiste em estabelecer as vazões corretas nos elementos terminais conforme previsto no projeto. A revisão bibliográfica apontou que o balanceamento aplicado à distribuição de ar passou a ser considerado no final dos anos de 1960. A aplicação de modelos matemáticos com a simulação do escoamento do ar nos dutos das redes tem início no final dos anos 80. No presente trabalho o objetivo foi estudar metodologia para simulação e balanceamento de redes de distribuição de ar, implementando-a em um programa de computador. Foram estudados diferentes métodos para realizar o balanceamento: método proporcional, método T e o método direto. Foi adotado o direto, em que as vazões são impostas e as diferenças de pressão determinadas para escoamentos em caminhos em paralelo. Mediante o uso de conceitos que fazem analogia entre a fluido-dinâmica e a eletricidade, foi desenvolvido um algoritmo e elaborado um programa de computador. O aplicativo desenvolvido possui 6 etapas principais: caracterização da rede, perda distribuída, perda localizada, perda total, simulação do escoamento e comparação de caminhos. A partir de um estudo de caso, o programa foi testado simulando uma rede de distribuição. Esta mesma rede teve seu balanceamento avaliado por cálculos em planilha eletrônica. Os resultados do estudo de caso com os valores de pressão para todos os trechos da rede, assim como as diferenças de pressão que definem a magnitude do balanceamento foram comparados e estão coincidentes dentro da margem esperada. / The balancing of a net air distribution consists in establishment the correct flowrate in the terminals elements according the design. The bibliographic review show that the balancing applied in air distribution are consider at the 60`s. In the end of the 80\\2019s the mathematics models beginning applied to air flow simulation in ducts. In the present work the objective is studies the methodology to simulation and balancing air distribution nets using software. Different methods are studies to apply in balance: proportional method, T method and direct method. The direct method is adopted, which the flowrate is fixed and the pressure difference is obtained for the parallel paths. Using fluid-dynamics and electrical analogy concepts an algorithm was developed and a software was prepared. The applicatory developed was divided in 6 main stages: net characterization, continuous losses, local losses, total losses, flow simulation and path comparing. Using a case study the software was tested and the distribution net was simulating. This same net was balancing evaluated by a computational spreadsheet. The case study results present the values of pressure for the sections of the net, and the pressure differences to obtained the balancing. This values was consider coincident with the expected.

Page generated in 0.5898 seconds