Spelling suggestions: "subject:"quantificação."" "subject:"uantificação.""
1 |
Quantificação de DNA em células com neoplasias intraepiteliais de graus I e II do colo uterino pela reação de feulgen em indivíduos do Nordeste brasileiroSilva Brito Lima, Jacqueline January 2001 (has links)
Made available in DSpace on 2014-06-12T15:55:09Z (GMT). No. of bitstreams: 2
arquivo9566_1.pdf: 1795256 bytes, checksum: caf7e8bc2ea232646c796e5819fe3e55 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2001 / A presente pesquisa tem como objetivo detectar variações de DNA nos
núcleos das células marcadas pela Reação Histoquímica de Feulgen, em indivíduos com
diagnóstico de Neoplasias Intraepiteliais Cervicais de Graus I e II (NIC I e II) do colo do
útero.
A microcitometria foi realizada em lâminas preparadas provenientes de
hospitais estaduais e universitário, submetidas à Reação Histoquímica de Feulgen, sendo
analisadas no sistema Image Lab para a mensuração e absorbância. Os resultados
encontrados entre as células neoplásicas dos graus I (NIC I) e II (NIC II) demonstraram que
o método é sensível e eficiente na ajuda da quantificação entre as diferentes classificações,
podendo, desta forma, auxiliar no diagnóstico das lesões do colo do útero em seu estágio
inicial
|
2 |
Desenvolvimento de uma metodologia baseada na espectroscopia no infravermelho próximo para determinação do produto de degradação do captopril em comprimidosSOUZA, Julia Aparecida Lourenço de 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T16:30:19Z (GMT). No. of bitstreams: 2
arquivo2761_1.pdf: 1236652 bytes, checksum: d37ffa408d97eceada1fdd00b1345471 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O captopril ingrediente ativo farmacêutico apresenta considerável estabilidade.
No entanto, é fortemente susceptível à degradação oxidativa causada por elevadas
temperaturas e umidade, ou ainda pela mistura a excipientes higroscópicos. A
degradação do captopril leva à formação do dissulfeto de captopril (DSC). O
aumento da quantidade do produto de degradação e a consequente diminuição do
princípio ativo, leva à perda da eficácia e segurança do medicamento, pois não
apresentará a dose terapêutica adequada ao tratamento dos pacientes. Além disso,
uma quantidade de DSC acima do valor máximo permitido que, segundo a 4ª edição
da Farmacopeia Brasileira é 3%, pode causar o aparecimento dos efeitos
indesejáveis no organismo. Deste modo, é de extrema importância a quantificação
do DSC em comprimidos. O presente trabalho propõe uma nova metodologia para a
determinação deste produto de degradação, baseada na espectroscopia na região
do infravermelho próximo e métodos quimiométricos. Para a realização deste estudo
foram utilizados 52 blisteres (520 comprimidos) de um mesmo lote recém-produzido,
coletados da linha de produção do LAFEPE. Destes, 12 blisteres (120 comprimidos)
foram utilizados para os ensaios de qualidade no tempo 0. Os 40 blisteres restantes
foram submetidos à degradação forçada por 6 meses, utilizando uma câmara
climática de estabilidade acelerada. A faixa de concentração de DSC utilizada para a
construção dos modelos de calibração foi de 0,1125 a 1,2100 mg (0,45 a 4,84%). Os
espectros NIR de refletância difusa de todos os lotes foram registrados na região de
14000 a 3800 cm-1, com resolução de 8 cm-1 e 32 varreduras. Os mesmos lotes
também foram analisados pelo método de referência (Cromatografia Líquida de Alta
Eficiência - CLAE). Vários pré-tratamentos espectrais foram testados e aquele que
mostrou melhor desempenho foi a 2a derivada utilizando o algoritmo Savitzky-Golay
com polinômio de segunda ordem e janela de 41 pontos. A validação interna do
modelo foi feita utilizando a validação cruzada completa e o número ideal de
variáveis latentes para a construção do modelo foi 5. O desempenho do modelo
desenvolvido foi testado a partir da previsão da concentração de DSC em um
conjunto externo contendo amostras de 20 lotes distintos (amostras de previsão) e
apresentou um RMSEP de 0,0750 mg, que representa um RSD de 13,72%. O
presente estudo confirma a aplicabilidade da espectroscopia NIR para a
quantificação do DSC em comprimidos. De acordo com os parâmetros de validação
a metodologia desenvolvida pode ser facilmente utilizada para análise de rotina, pois
é uma técnica não invasiva, não destrutiva, rápida e não utiliza reagentes químicos
prejudiciais ao meio ambiente
|
3 |
Preparação, caracterização e aplicação de carbono polimérico vítreo em sensores eletroquímicosSilva, Luiz Fernando da [UNESP] 31 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2007-07-31Bitstream added on 2014-06-13T18:46:18Z : No. of bitstreams: 1
silva_lf_dr_araiq.pdf: 4030863 bytes, checksum: 7c57ebacea6fa967402841847b7f8265 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A rota sintética do carbono vítreo é bem conhecida, da mesma forma, são notórias suas propriedades estruturais e condutoras, como também as aplicações deste material, principalmente em eletroquímica. Todavia, existe uma classe de materiais com base em carbono, que possui propriedades similares as do carbono vítreo, mas ainda são pouco destacados na pesquisa acadêmica. Estes materiais são obtidos a partir da pirólise de resinas poliméricas como as fenólicas, furfurílica e poliacrilato, e que apresentam condutividade elétrica e térmica e boa resistência mecânica. Entretanto, por serem tratados a temperaturas (até 1200ºC), inferiores a de produção do carbono vítreo podem possuir falhas na sua estrutura, que podem causar variações previsíveis ou não, em seu comportamento eletroquímico, como menor condutividade ou maior afinidade com determinadas moléculas. Pertencendo a esta classe se encontra o carbono polimérico vítreo (CPV) material similar ao carbono vítreo comercial, mas que em sua estrutura ainda conserva características do precursor, como grupos funcionais hidroxílicos e carboxílicos. Dessa forma, este trabalho apresenta a obtenção do CPV a partir de uma resina fenólica comercial, estuda suas propriedades estruturais e eletroquímicas, sendo que para isso foi desenvolvido o processo de síntese, foram efetuados experimentos de caracterização com técnicas de análise termogravimétrica com análise térmica diferencial, difração de raios-X, infravermelho com transformada de Fourrier, voltametria cíclica e espectroscopia de impedância eletroquímica. O comportamento eletroquímico, utilizando o sistema ferricianeto/ferrocianeto, é similar ao obtido com eletrodo comercial de carbono vítreo e platina. O material possui estabilidade térmica em atmosfera oxidante até o limite de temperatura de 600ºC. Já em atmosfera inerte apresenta... / The synthetic route to obtain glassy carbon is well known, as well as its structural and conductive properties and its use in electrochemistry. However, there is a class of based carbon material which possesses similar properties to glassy carbon, but with a lack of interest in academic community. These materials are produced from pyrolysis of either phenolic or furfurylic resin, named glassy polymeric carbon, and they present thermal stability, robustness, mechanical strength, electrical conductivity and large potential range. Notwithstanding these characteristics, as these carbon based materials is prepared at low temperature (approximately 1200 oC) some kilning faults can be arisen leading to predictable changes in electrochemical behavior. In addition, after the preparation, glassy polymeric carbon maintains functional groups such as carboxyl and hydroxyl. In this context, the present work describes the synthesis of glassy carbon from commercial phenolic resin, structural characterization, and the application as working electrode and the potential use as support to chemically modified electrodes. The electrochemical behavior by using hexacyanoferrate system is quite similar to glassy carbon and platinum commercial electrodes. Moreover, the obtained carbon material is thermally stable under air atmosphere up to 600 oC and decomposes slightly up to 1050 oC under inert condition. Afterwards, the glassy polymeric electrode was found to be a useful tool for electroanalytical purposes. In particularly, it was developed a electrochemical sensor to caffeic acid in complex matrix such as red wine by applying voltammetric techniques (cyclic voltammetry, square wave and differential pulse voltammetry). Furthermore, it was investigated the effect of metallic ion doping and surfactant molecules during the synthesis on the properties of the glassy polymeric carbon. In fact, these set of experiments...(Complete abstract click electronic access below)
|
4 |
Preparação, caracterização e aplicação de carbono polimérico vítreo em sensores eletroquímicos /Silva, Luiz Fernando da. January 2007 (has links)
Resumo: A rota sintética do carbono vítreo é bem conhecida, da mesma forma, são notórias suas propriedades estruturais e condutoras, como também as aplicações deste material, principalmente em eletroquímica. Todavia, existe uma classe de materiais com base em carbono, que possui propriedades similares as do carbono vítreo, mas ainda são pouco destacados na pesquisa acadêmica. Estes materiais são obtidos a partir da pirólise de resinas poliméricas como as fenólicas, furfurílica e poliacrilato, e que apresentam condutividade elétrica e térmica e boa resistência mecânica. Entretanto, por serem tratados a temperaturas (até 1200ºC), inferiores a de produção do carbono vítreo podem possuir "falhas" na sua estrutura, que podem causar variações previsíveis ou não, em seu comportamento eletroquímico, como menor condutividade ou maior afinidade com determinadas moléculas. Pertencendo a esta classe se encontra o carbono polimérico vítreo (CPV) material similar ao carbono vítreo comercial, mas que em sua estrutura ainda conserva características do precursor, como grupos funcionais hidroxílicos e carboxílicos. Dessa forma, este trabalho apresenta a obtenção do CPV a partir de uma resina fenólica comercial, estuda suas propriedades estruturais e eletroquímicas, sendo que para isso foi desenvolvido o processo de síntese, foram efetuados experimentos de caracterização com técnicas de análise termogravimétrica com análise térmica diferencial, difração de raios-X, infravermelho com transformada de Fourrier, voltametria cíclica e espectroscopia de impedância eletroquímica. O comportamento eletroquímico, utilizando o sistema ferricianeto/ferrocianeto, é similar ao obtido com eletrodo comercial de carbono vítreo e platina. O material possui estabilidade térmica em atmosfera oxidante até o limite de temperatura de 600ºC. Já em atmosfera inerte apresenta...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The synthetic route to obtain glassy carbon is well known, as well as its structural and conductive properties and its use in electrochemistry. However, there is a class of based carbon material which possesses similar properties to glassy carbon, but with a lack of interest in academic community. These materials are produced from pyrolysis of either phenolic or furfurylic resin, named glassy polymeric carbon, and they present thermal stability, robustness, mechanical strength, electrical conductivity and large potential range. Notwithstanding these characteristics, as these carbon based materials is prepared at low temperature (approximately 1200 oC) some kilning faults can be arisen leading to predictable changes in electrochemical behavior. In addition, after the preparation, glassy polymeric carbon maintains functional groups such as carboxyl and hydroxyl. In this context, the present work describes the synthesis of glassy carbon from commercial phenolic resin, structural characterization, and the application as working electrode and the potential use as support to chemically modified electrodes. The electrochemical behavior by using hexacyanoferrate system is quite similar to glassy carbon and platinum commercial electrodes. Moreover, the obtained carbon material is thermally stable under air atmosphere up to 600 oC and decomposes slightly up to 1050 oC under inert condition. Afterwards, the glassy polymeric electrode was found to be a useful tool for electroanalytical purposes. In particularly, it was developed a electrochemical sensor to caffeic acid in complex matrix such as red wine by applying voltammetric techniques (cyclic voltammetry, square wave and differential pulse voltammetry). Furthermore, it was investigated the effect of metallic ion doping and surfactant molecules during the synthesis on the properties of the glassy polymeric carbon. In fact, these set of experiments...(Complete abstract click electronic access below) / Orientador: Nelson Ramos Stradiotto / Coorientador: Herenilton Paulino Oliveira / Banca: Paulo Olivi / Banca: Luiz Henrique Mazo / Banca: Grégore Jean-François Demets / Banca: Lauro Tatsuo Kubota / Doutor
|
5 |
Ferramenta automática para quantificação volumétrica dos seios maxilares em imagens de tomografia computadorizadaGiacomini, Guilherme. January 2017 (has links)
Orientador: Diana Rodrigues de Pina / Resumo: O volume é um dos fatores mais importantes na avaliação dos seios paranasais. A literatura mostra uma falta de consenso em estudos de volume dos seios maxilares (SMs). Isto pode ser atribuído às diferentes técnicas de aquisição dos exames de tomografia computadorizada, diferentes métodos de segmentação e diferentes objetos de estudo. Além disto, métodos de quantificação volumétrica são comumente manuais ou semiautomáticos, necessitando de alta experiência e tempo do usuário. A padronização das medidas de SMs é extremamente importante para determinação dos fatores que influenciam o tamanho desta região anatômica sob condições normais e patológicas, bem como para entendimento das funções dos SMs. Métodos de quantificação ainda podem auxiliar em estudos detalhados da estrutura anatômica dos SMs de modo a auxiliar no planejamento de cirurgias endoscópicas e de procedimentos odontológicos de levantamento do assoalho desta região. Também podem auxiliar na verificação de resposta à tratamentos em diferentes patologias, tais como a presença de rinossinusite, tumores, cistos, entre outras. O objetivo deste estudo foi o desenvolvimento de uma ferramenta automática para quantificar o volume total e de ar livre presente nos SMs, utilizando exames de tomografia computadorizada. A ferramenta desenvolvida exclui qualquer variabilidade resultante dos procedimentos de medição e separa as regiões de ar livre e de comprometimento dentro dos SMs sadios e patológicos. O volume dos SMs foi quantif... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
|
6 |
A forma lógica de sentenças de existência: uma avaliação da abordagem quantificacional / The logic form of existencial sentences: an avaluation of quanticational approachPontes, André Nascimento January 2010 (has links)
PONTES, André Nascimento. A forma lógica de sentenças de existência: uma avaliação da abordagem quantificacional. 2010. 101f. – Dissertação (Mestrado) – Universidade Federal do Ceará, Programa de Pós-graduação em Filosofia, Fortaleza (CE), 2010. / Submitted by Gustavo Daher (gdaherufc@hotmail.com) on 2017-09-20T15:19:09Z
No. of bitstreams: 1
2010_dis_anpontes.pdf: 596782 bytes, checksum: cdf303737f283864797e797d93cae2fb (MD5) / Approved for entry into archive by Márcia Araújo (marcia_m_bezerra@yahoo.com.br) on 2017-09-23T14:25:20Z (GMT) No. of bitstreams: 1
2010_dis_anpontes.pdf: 596782 bytes, checksum: cdf303737f283864797e797d93cae2fb (MD5) / Made available in DSpace on 2017-09-23T14:25:20Z (GMT). No. of bitstreams: 1
2010_dis_anpontes.pdf: 596782 bytes, checksum: cdf303737f283864797e797d93cae2fb (MD5)
Previous issue date: 2010 / The objective of this work is to present an evaluation of the quantificational approach of the problem of existence in the versions defended by Frege, Russell and Quine. This approach is presented having as a background its reaction to the classic model of sentence analysis used by inflationed ontologies derived from Plato’s nonbeing argument, as well as from the Meinong’s Theory of Objects. The basic idea is to show that the inflationed ontology claimed by Plato and Meinong - which, in the most part, is derived from a deficient model of sentence analysis -, can be eliminated through an efficient logical treatment of existence utterances based on the logic of predicates. In spite of internal divergences, the central thesis of proponents of the quantificational approach is that the existence predicate is, from a logical point of view, represented by the existential quantifier (E) of the logic of predicates. I also try to show that, although the quantificational approach represents an advance without precedents in the philosophy concerning to the logical status analysis of the term “exist”, it has some relevant limitations which its proponents have not overcome yet. / O objetivo desse trabalho é apresentar uma avaliação da abordagem quantificacional do problema da existência nas versões defendidas por Frege, Russell e Quine. Tal abordagem é apresentada tendo como pano de fundo sua reação ao modelo clássico de análise de sentenças utilizado pelas ontologias inflacionadas derivadas do argumento do não-ser de Platão e da Teoria dos Objetos de Meinong. A ideia básica é mostrar que a ontologia inflacionada sustentada por Platão e Meinong que, em grande parte, é derivada de um modelo deficiente de análise de sentenças, pode ser eliminada através de um tratamento lógico eficiente de enunciados de existência com base na lógica de predicados. A despeito das divergências internas, a tese central dos proponentes da abordagem quantificacional é que o predicado de existência é, do ponto de vista lógico, representado pelo quantificador existencial (E) da lógica de predicados. Tento mostrar também que, embora a abordagem quantificacional represente um avanço sem precedentes em filosofia no que diz respeito à análise do estatuto lógico do termo “existe”, ela possui algumas limitações relevantes que seus proponentes até então não conseguiram superar.
|
7 |
USO DE RESSONÂNCIA MAGNÉTICA NUCLEAR (RMN) PARA ANÁLISE DE COCAÍNA E SEUS ADULTERANTESGAMA, L. A. 27 August 2014 (has links)
Made available in DSpace on 2016-08-29T15:35:36Z (GMT). No. of bitstreams: 1
tese_8107_LUCAS DE ALMEIDA GAMA20141202-143805.pdf: 4996710 bytes, checksum: ee8465315ab132ba2e49f39bf08cad52 (MD5)
Previous issue date: 2014-08-27 / As análises de drogas de abuso são realizadas principalmente por técnicas analíticas como a cromatografia gasosa, podendo estar acoplada com a espectrometria de massas (CG/MS), e também técnicas de infravermelho (IV). Outras técnicas que antes eram inviáveis, tanto pelo alto custo dos equipamentos quanto pela baixa sensibilidade, agora estão se tornando técnicas viáveis para análises destas drogas. Um exemplo disso é a Ressonância Magnética Nuclear (RMN), que devido a necessidade de uma quantidade maior de amostra e ao alto custo de solventes deuterados, empregados na dissolução da amostra, tornavam a RMN uma técnica com alto custo agregado.
Neste trabalho, foram realizados estudos de RMN sem a utilização de solvente deuterado na diluição das amostras de cocaína apreendidas pela Polícia Civil do Estado do Espírito Santo, denominada No-D NMR. A aplicação desta técnica diminui o custo das análises uma vez que não são utilizados compostos deuterados como solvente. Como se tratava de uma nova metodologia de análise, otimizou-se parâmetros de aquisição e de processamento característicos da RMN. A qualidade espectral obtida permitiu a distinção dos sinais característicos da cocaína e seus principais adulterantes: cafeína, fenacetina e lidocaína.
Uma segunda etapa deste trabalho foi a aplicação de figuras de mérito para validar a No-D NMR como uma nova metodologia de quantificar a cocaína e seus principais adulterantes. Foram realizados estudos de especificidade/seletividade, linearidade, limite de detecção (LD), limite de quantificação (LQ) e exatidão/precisão que mostraram que a metodologia proposta é adequada para quantificar as substâncias em apreensões de cocaína. Após a obtenção das figuras de mérito, quantificou-se 29 apreensões que possuíam uma baixa quantidade de cocaína (cerca de 24% em massa) o que demonstrou que ocorre muita adulteração das amostras comercializadas no Espírito Santo.
|
8 |
Marcadores Inserção/Deleção na quantificação de quimerismo hematopoiético / Insertion/Deletion markers for quantification of hematopoietic chimerism bySantos, Marcela Dambrowski dos 21 December 2018 (has links)
Introdução: Métodos quantitativos sensíveis e acurados para monitorar o quimerismo hematopoiético após Transplante de Células-Tronco Hematopoiéticas (TCTH) são necessários para verificar o sucesso do enxerto, uma vez que os resultados influenciam a abordagem terapêutica. Método: A técnica de detecção de DNA baseada em primers inserção-específicos de marcadores genéticos do tipo InDel (Inserção/Deleção) foi avaliada quanto a sua utilidade em quantificar quimerismo em amostras de DNA em baixa concentração, em PCR em Tempo Real (qPCR). Para isso, amostras de DNA de dez pacientes submetidos a Transplante de Medula Óssea (TMO) foram analisados para quantificar a concentração de DNA residual em diferentes períodos pós-transplante. Os resultados obtidos pela InDelqPCR foram comparados com a evolução clínica descrita nos prontuários. Resultados: As quantificações do DNA residual variaram de 0,021 ng/µL a 11,71 ng/µL, correspondendo a fração de 0,065% a 40,6% do DNA total presente na amostra. Os resultados obtidos (presença ou ausência do alelo inserção) foram condizentes com a evolução clínica dos pacientes, em alguns casos, evidenciando quimerismo prévio ao relatado nos prontuários. Conclusão: Nossos dados demonstram a utilidade do método InDel-qPCR, baseada em primers inserçãoespecíficos, no monitoramento de quimerismo hematopoiético. / Introduction: Sensitive and accurate quantitative methods to monitor hematopoietic chimerism after Hematopoietic Stem Cell Transplantation (HSCT) are necessary to evaluate engraftment since the results influence a therapeutic approach. Method: DNA detection technique based on insert-specific primers for Insertion/Deletion polymorphism (InDel) was evaluated for chimerism quantification of samples with low amounts of DNA, by quantitative real-time polymerase chain reaction (qPCR). Samples of patients undergoing Bone Marrow Transplantation (BMT) collected at different post-transplantation times were analyzed to quantify the residual DNA concentration. Then, the results found using InDel-qPCR were compared to the medical records. Results: DNA quantifications ranged from 0.021 ng/?L to 11.71 ng/?L, corresponding to a fraction of 0.065% to 40.6% of the total DNA. Our results, in some cases, shows chimerism presence previously to that reported in the medical records. Conclusion: Our data demonstrate the usefulness of the InDelqPCR method based on insertion-specific primers in the monitoring of hematopoietic chimerism.
|
9 |
Mapeamento granulométrico do solo via imagens de satélite e atributos de relevo / Mapping topsoil texture by satellite image and reliefFongaro, Caio Troula 20 January 2016 (has links)
O planeta terra tem grande dimensão, e seus recursos naturais precisam ser mapeados e conhecidos para nortear políticas públicas. O solo é um destes importantes recursos. O seu conhecimento passa pela caracterização e mapeamento pedológico e/ou de seus atributos. Para o adequado monitoramento, é necessário o conhecimento em escala detalhadas. Isto demanda recursos humanos, altos custos financeiros e de logística. Fato este ainda difícil de se atingir. Logo, é preciso investir em tecnologias que auxiliem na rápida obtenção de informações de qualidade, à baixo custo. Tendo em vista as áreas agrícolas da região de estudo, os objetivos deste trabalho foram: (i) definir uma metodologia que identifique em imagens de satélite, locais de o solo exposto; (ii) Mapear os teores granulométricos através de imagens de satélite e atributos do relevo, utilizou-se das imagens compostas do tópico (i). A área de estudo localiza-se na região de Araraquara, São Paulo, Brasil, com dimensão de 14.614 km2. Dentro desta área foram demarcados 952 pontos para coleta de amostras de terra na camada superficial, as quais foram georreferenciadas e analisadas granulometricamente em laboratório. Sua demarcação seguiu os preceitos do método da topossequência com o intuito de representar a variabilidade da região. Foram obtidas imagens do satélite Landsat 5 (sensor TM) multitemporais as quais foram processadas e transformadas em reflectância. As amostras de terra coletadas em campo passaram por sensor em laboratório (400-2500 nm), os espectros laboratoriais foram utilizados para validar aqueles obtidos nas imagens de satélite. Para tanto, nos locais onde foram coletadas as amostras, foram extraídos os dados espectrais dos pixels perfazendo os gráficos das curvas espectrais. Estas foram comparadas com os dados de obtidos em laboratório simulados. Feita a correlação, as imagens passaram por processos de eliminação de objetos que não fossem solo. Todas as imagens multitemporais foram finalizadas contendo apenas solo exposto, as quais dentro do software R foram sobrepostas e gerou-se uma imagem composta, com apenas solo exposto. Os resultados mostraram que as curvas espectrais de laboratório foram extremamente semelhantes aos das imagens de satélite, seguindo a lógica das variações texturais. Além disso, as técnicas de componentes principais e relação entre bandas 3-4, 5-7, e correlação entre bandas (sendo a mais expressiva com r de 0,87 entre TM7), comprovaram que a imagem apresentou solo exposto. Se um usuário utilizar-se somente uma imagem para estudar solos, teria na faixa de 4% de solo exposto, porém utilizando a técnica de composição de imagens, atingiria 43%. Não obstante, se a área de estudo fosse 100 % com agricultura poderia atingir 95% de solo exposto. Num segundo momento, o trabalho comprova, com o modelo Cubist, que tanto por imagens de satélite quanto por relevo foi possível quantificar os teores de argila da área da camada superficial, atingindo R2 de ≈0,65. No entanto, a qualidade visual do mapa gerado por relevo é ruim. Porém, quando se integra dados de imagens, relevo e geomorfologia, este resultado é de 0,72 e apresenta o melhor resultado visual. / Planet Earth has great dimension, and its natural resources has to be mapped and monitored, looking towards correct decisions. Soil is one of these important resources. Know soils is related with its caracterization and mapping by pedological and attributes recognition. For soil monitoring, its necessary maps in large scale, which demand man power and high cost. Thus, its necessary to invest in geotechnologies, to reach the goal faster and low cost. The objective of this work was to determine a method to determine exposed soils in satellite images, even when have vegetation, taking in account a multitemporal dataset, in agricultural areas, where as in a given season will have exposed soils. b. quantify clay and sand contents by satellite images and relief attributes. The area is located in Araraquara, SP, Brazil, with a 14.614 km2 dimension. We collected soil samples all over the area with a total of 952 points and 0-20 cm depth, georeferenced, representative of the area. Samples were granulometric analysed and afterwards passed throgh a vis-nir-swir sensor (400-2500 nm). We collected multitemporal images from landsat satellite from september and october n the last 15 years. Images were atmospheric corrected and transformed into reflectance. Laboratory spectral data was used to validate pixels spectra information from satellite. We extracted all objects which were not soils from all images. Using R software, we merged the multitemporal images and performed a unique bare soil image. Also, we made processing on the DEM of the área reaching several soil attribute factors. Results indicated as follows: a. labortory spectral curves validated satellite data; b) principal componentes and relation between bands ¾ and 5/7 reached great R2 until 0,87 between laboratory and satellite data; d) a user could reach 1,21% of na image with bare soil, while with our method could reach 43% in the entire image. On the other hand, if the user have only agriculture area, could reach until 95% with bare soil. In a second step of this work, we prove that by regression tree statistics, clay and sand content can be quantified by satellite images with a 0,62 of R2, as also with terrain atributes. On the other hand, when we associate image spectral data with terrain atributes, we can reach 0,72 on clay quantification. Despite this, the visual aspecto of data, is better using image data than relief , which presented more noise. Another conclusion, is that images could substitute geology information in the models. This work can considerably assist pedologists, farmers and environment professionals on soil monitoring.
|
10 |
\"Quantificação de MDMA em amostras de ecstasy por cromatografia em fase gasosa (GC/NPD)\" / Quantification of MDMA in ecstasy samples by gas chromatography (GC/NPD)Lapachinske, Silvio Fernandes 31 March 2004 (has links)
Quimicamente, o ecstasy é a 3,4-metilenodioximetanfetamina (MDMA), um composto sintético com propriedades estimulante central e alucinogênicas. Algumas substâncias análogas à MDMA, já identificadas em comprimidos de ecstasy, são principalmente: 3,4-metilenodioxietilanfetamina (MDEA), 3,4-metilenodioxianfetamina (MDA), metanfetamina e anfetamina. Os adulterantes mais comuns, normalmente encontrados são: cafeína e efedrinas. O objetivo deste trabalho foi a validação de um método analítico para quantificar a MDMA em comprimidos e cápsulas de ecstasy, através da cromatografia em fase gasosa com detector de nitrogênio/fósforo (GC/NPD). Substâncias análogas à MDMA e adulterantes também foram identificados. Amostras de comprimidos e cápsulas de 25 diferentes lotes, apreendidos como ecstasy em São Paulo (SP), foram analisadas pelo método proposto. Desse total de amostras, 21 continham somente MDMA (84%) e apenas 1 delas apresentou MDMA associada com cafeína (4%). A concentração total de MDMA nessas amostras variou entre 30,9 e 92,7mg, resultando em uma média aritmética de 63mg. / Chemically, \"ecstasy\" is 3,4-methylenedioxymethamphetamine (MDMA), a synthetic compound with stimulant and hallucinogenic properties. Some MDMA analog substances such as 3,4-methylenedioxyethylamphetamine (MDEA), 3,4-methylenedioxyamphetamine (MDA), methamphetamine and amphetamine have already been identified in \"ecstasy\" tablets. Caffeine and ephedrines are the most common adulterants also found. The aim of this paper is to describe the validation of an analytical method to quantify MDMA in \"ecstasy\" tablets and capsules. Gas chromatography with nitrogen/phosphorus detector was used in the method. Analog substances to MDMA and adulterant compounds were also identified. Samples from 25 lots of tablets seized in the city of São Paulo were analyzed. From that total, 21 showed only MDMA (84%) and just 1 of them presented MDMA plus caffeine (4%). MDMA total concentration in these samples had a variation between 30.9 and 92.7mg, resulting in an arithmetic average of 63mg.
|
Page generated in 0.067 seconds