• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • Tagged with
  • 42
  • 42
  • 15
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Modelo experimental de mucosite oral induzida por radioterapia de megavoltagem â papel protetor da pentoxifilina / Experimental model of oral mucositis radio-induced by megavoltage â the protective role of the pentoxyfilline

Josà Fernando Bastos Moura 20 December 2006 (has links)
CoordenaÃÃo de AperfeiÃoamento de NÃvel Superior / CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / A mucosite ou estomatite oral (MO), que consiste na resposta inflamatÃria da mucosa oral à aÃÃo de drogas ou radioterapia, onstitui-se num efeito colateral debilitante, sendo uma complicaÃÃo potencialmente sÃria, dose-limitante que tem impacto tanto no controle local quanto na sobrevida e qualidade de vida de pacientes oncolÃgicos. O objetivo deste trabalho foi desenvolver um modelo de MO induzida por radioterapia (RXT) em aparelho de megavoltagem - cobalto-60 (MV - Co60) e avaliar o papel protetor do agente inibidor de citocinas, pentoxifilina (PTX). Foram utilizados 156 hÃmsters Golden Siriam machos com massa corpÃrea mÃdia de 139 gramas. Os animais foram submetidos à RXT da mucosa jugal, utilizando aparelho de MV - Co60. A irradiaÃÃo foi realizada no dia um com campo direto e colocaÃÃo de bolus sobre a mucosa e dose Ãnica de 35 Gy. No quarto dia foram feitas irritaÃÃes mecÃnicas (IM) na mucosa jugal irradiada, como fator potencializador da MO. Os animais foram observados por um perÃodo de 16 dias, ao longo do qual a mucosa foi avaliada macroscopicamente considerando os aspectos de hiperemia, Ãreas hemorrÃgicas, Ãlceras e abscessos. Em dias prÃ- determinados (7, 10, 13 e 16 dias), os animais foram sacrificados e as mucosas removidas e processadas para anÃlise histopatolÃgica (infiltrado celular, dilataÃÃo e ingurgitamento vascular, hemorragia, edema, Ãlceras e abscessos), dosagem da mieloperoxidase e detecÃÃo de TNF-&#945; por imunohistoquÃmica. Antes do sacrifÃcio, foi colhido sangue para contagem total e diferencial de leucÃcitos. Os animais foram pesados diariamente e avaliados quanto as suas respectivas variaÃÃes da massa corpÃrea e realizado tambÃm estudo da curva de sobrevida. No 13 dia, observou-se o pico de intensidade dos achados inflamatÃtios. A PTX foi utilizada nas doses de 5, 15 e 45 mg kg-1sc, 1 h antes da radioterapia e, diariamente,por 13 dias. Observou-se que a induÃÃo da MO causou lesÃes significantes a partir do 7 dia,atingindo pico entre os dias 13 e 16, com aumento significante de marcaÃÃo de TNF-&#945;, sem alteraÃÃo do hemograma dos animais. Contudo, a induÃÃo da MO causou perda significante de peso a partir do 5 dia, mantendo-se estÃvel atà o 13 dia, quando, entÃo se observou queda acentuada e significante da sobrevida dos animais atà o 16 dia. A PTX (15 mg kg-1) foi capaz de reduzir hiperemia, hemorragia, Ãlceras e abscessos (0; 0-2), quando comparada a animais com MO nÃo tratados (salina) com PTX (3; 2-3) (p<0,05). Estes dados foram confirmados pela anÃlise histopatolÃgica das mucosas, onde PTX 15 mg kg-1 (1; 1-3) reduziu o infiltrado inflamatÃrio, dilataÃÃo e ingurgitamento vasculares, edema, Ãlceras e abscessos, quando comparada aos animais que receberam apenas Salina (3; 1-3) (p<0,05). Ainda, PTX 15 mg kg-1reduziu, a marcaÃÃo do TNF-&#945; nas mucosas com MO, quando comparada aos animais nÃo tratados. A PTX nÃo alterou o hemograma, nem a variaÃÃo de massa corpÃrea observada na MO. Em resumo, o modelo de MO induzido por radioterapia de megavoltagem e irritaÃÃo mecÃnica em hamster foi desenvolvido e em concordÃncia ao modelo descrito na literatura por ortovoltagem, mostra caracterÃsticas que em muito se assemelham à mucosite oral humana, em termos de achados macroscÃpicos, histopatolÃgicos e bioquÃmicos, portanto, se prestando para o estudo de novas drogas capazes de combatÃ-la. Quanto à aÃÃo da PTX, foi observado um efeito protetor deste agente na dose de 15 mg kg-1, confirmado pela avaliaÃÃo do mediador inflamatÃrio TNF-&#945; e tambÃm um possÃvel efeito de radiossensibilizaÃÃo na dose de 45 mg kg1 / The oral mucositis (OM) consists of an inflammatory esponse of the oral mucosa to the drugs or radiation therapy and is a deleterious side effect and a potential serious complication,limiting-dose and impacting the local control, overall survival and quality of life in oncology patients. The objective of this study was to develop a OM model radio-induced (RXT) by amegavoltage machine â cobalt unit (MV - 60Co) and evaluate the protector role of the cytokinesinhibitor agent, pentoxyfilline (PTX). For this purpose, 146 male Golden Siriam Hamsters withme dium body mass of 139 grams were used. On the first day, the animals were exposed tomegavoltage irradiation in a cobalt unit, with a single fraction of 35 Gy. A irradiation field was opened to the oral mucosa and it was used a bolus on it. After the 4th day of irradiation, a mechanical scratching (MS) was done over the irradiated oral mucosa for nhancing the OM.The animals were observed for 16 days period in which the oral mucosa was evaluated macroscopically considering the clinical aspects of hyperemia, bleeding areas, ulcers and infections. In pre-determined days (days 7, 10, 13 and 16), the animals were sacrificed and the oral mucosa removed to be analyzed under the histopathological aspects (cellular effusion,vascular dilatation, bleeding, edema, ulcers and infection), mieloperoxidase dosage and TNF-&#945; detection by munohistochemical stain. Before the animals were sacrificed, a blood sample was drawn to count the white cells. The animals were daily weighed and evaluated about their bodymass variations and a survival curve was taken. On the 13th day, it was observed the highest inflammatory finding. The PTX was used in the following doses: 5, 15 and 45 mg kg-1 sc, one hour before the irradiation and daily, for 13 days. It was observed that the induced OM was greatly significant after the 7th day, with the higher findings of TNF-&#945; without blood counting changes between 13 to 16 days. The weight loss was detected after the 5th day and remained stable till 13th day when it was noticed a highly significant weight loss and survival till the 16th day. The PTX (15 mg kg-1) was able to reduce the hyperemia, bleeding, ulcers and infection (0; 0-2) when compared to the animals that received only saline solution (3; 1-3) (p < 0,05). The PTX 15 mg kg-1 reduced the TNF-&#945; stain in the oral mucosa with OM when compared to the animals that were not treated. The PTX altered neither the blood counting nor the body mass in the OM group. In summary, the OM model induced by megavoltage irradiation and mechanical scratching in hamsters was developed accordingly to the model designed to ortovoltage studies in the literature, shows close relationship to the human oral mucosa changes, macroscopically, histopathologically and biochemically, and it can be used in the study of new drugs to prevent mucositis. About the PTX action, it was observed the protector effect of this agent in the 15 mg kg-1 dosage, confirmed by the evaluation of the TNF-&#945; and its possible radiation sensitivity effect in the 45 mg kg-1 dosage
22

Doses e risco de radiação em estudo tomográfico computadorizado do tórax com tecnologia de quatro cortes

Andréa de Lima Bastos 25 August 2006 (has links)
Nenhuma / A tomografia computadorizada (TC) do tórax constitui um dos principais métodos de estudo das patologias torácicas, fornecendo análise morfológica e funcional e permitindo desta forma uma abordagem terapêutica mais específica das alterações condicionadas pelas doenças. Entretanto, deve-se considerar que por envolver radiação ionizante no seu processo, este procedimento apresenta os riscos inerentes a esta e sua utilização deve resultar de um balanço preciso entre o custo e o benefício propiciado pelo procedimento. A proteção de pacientes submetidos a exames radiológicos, de uma maneira geral, é determinada pelos princípios da justificação e otimização. Desta forma, torna-se importante hoje em dia, o conhecimento dos níveis de radiação nas exposições envolvidos durante um procedimento tomográfico. Estes níveis foram observados através da estimativa das grandezas específicas para tomografia computadorizada, o Índice de Dose para Tomografia Computadorizada no ar (CTDI100,ar ) e o Índice de Dose ponderada para Tomografia Computadorizada (CTDIw) , e em seguida dos níveis de dose absorvida em órgãos durante um estudo tomográfico computadorizado do tórax realizado com varredura única. Os descritores de dose específicos para a tomografia foram estimados através da irradiação, em tomógrafo multidetector de quatro cortes, de uma câmara de ionização tipo lápis de forma livre no ar para a determinação do CTDI100,ar e dentro do simulador de tronco para a determinação do CTDIw. Os valores obtidos foram comparados com os valores fornecidos pelo fabricante e também com os valores obtidos por análise computacional. Eles foram utilizados, neste estudo, no cálculo da Dose Efetiva e para comparação com o nível de referência de dose estabelecido pela comunidade européia. Utilizando-se o programa de simulação computacional do grupo IMPACT, foram determinadas as grandezas de radioproteção relevantes para o estudo que são os valores de dose absorvida em órgãos e a dose efetiva referente ao procedimento. O nível do Produto dose comprimento (DLP), utilizando-se o CTDI100, ar previamente estabelecido, foi também obtido e comparado com o nível de referência de dose estabelecido pela comunidade européia. Os valores de dose absorvida em órgãos foram ainda utilizados para a estimativa do risco relacionado ao procedimento de acordo com as sugestões de cálculo da Comissão Internacional de Proteção Radiológica. Desta forma observamos que os níveis de exposição aos raios X proporcionados pela técnica com multidetetores de quatro fileiras e varredura única, permanecem dentro dos níveis conhecidos para os estudos envolvendo a tecnologia convencional e helicoidal, apesar do aumento significativo de informações proporcionadas. Os valores de CTDIw e DLP obtidos neste estudo encontram-se dentro dos níveis de referência diagnóstica sugeridos como padrões de boa prática pela comunidade européia. Os valores de doses em órgãos obtidos com esta técnica foi semelhante ao observado na literatura em relação ao estudo tomográfico do tórax. Neste estudo, considerando-se a grande incerteza associada a estes cálculos, podemos observar um risco maior para o pulmão, mama, medula óssea e esôfago. / The computerized tomography (CT) is an important method for studying chest pathologies to provide its morphological and functional analysis and to allow a specific therapeutic approach of signs or symptoms resulting from diseases. Since CT uses ionizing radiation, it should be considered that a precise balance between risks and benefits must be achieved in order to justify the adoption of such technique. Radiation protection of patients undergoing radiological exams is established based on the justification and optimization principles. Nowadays, it is important to know the dose radiation levels to which a patient is exposed during a tomographic procedure. Those are given by the estimation of specific dosimetric quantities called the computed tomography dose index in air, CTDI100,air and the weighted computed tomography dose index CTDIw , and the organ absorbed doses that are given to the patient during a chest CT with a single scanning. In this work, the CTDI100,air and the CTDIw were determined through measurements with a pencil ionization chamber free-in-air and in a trunk phantom.Results werecompared to values provided by the manufacturer and those that were calculated by computational methods. The protection quantities organ absorbed dose and effective dose, which are relevant to this work, were determined with a computational program from the IMPACT group. The dose length product DLP level was calculated from the CTDI100, air and compared to the reference dose level established by the European Community. Risk values were estimated based on the organ absorbed doses according to the procedure recommended by the International Commission on Radiological Protection. Although the significant increase on diagnostic information, results showed that x-ray dose levels from four-array multidetector CT system in a single-scanning were not so different to the published one from studies with the conventional and helical techniques. CTDIw and DLP values got in this work agreed with the diagnostic dose reference levels recommended by the European Community as standard for good practices. Organ doses provided by the studied chest tomography technique also agreed with those values published elsewhere. Although the dose results showed a large uncertainty in their values, it was observed that radiation risks were large in lungs, breast, bone marrow and esophagus.
23

Controle de qualidade e dose de entrada na pele em serviços de mamografia de Minas Gerais

Maurício de Oliveira 28 August 2006 (has links)
Nenhuma / Em exames que fazem uso da radiação ionizante, a dose a que o paciente é exposto deve ser mantida tão baixa quanto possível, de acordo com os princípios da proteção radiológica, porém sem comprometer a qualidade da imagem, que vai possibilitar o seu uso como ferramenta útil para o diagnóstico. A obtenção de imagens com definição e contraste satisfatórios pode ser alcançada com uma adequação do feixe de radiação e também com a escolha correta do sistema receptor e do seu processamento adequado. A mama é composta por estruturas com densidades muito próximas o que aumenta a dificuldade na obtenção de contraste desejado na imagem formada pelos raios X. Esse fator associado à qualidade da radiação, à compressão da mama, ao uso de grade, ao sistema filme-écran, e ao processamento dos filmes são fatores que influenciam no contraste da imagem mamográfica. Neste trabalho, a proposta foi levantar a situação dos serviços de mamografia do estado de Minas Gerais, através de uma amostra desses serviços e estabelecer procedimentos de garantia de qualidade e controle de risco, sob o ponto de vista de proteção radiológica e qualidade dos exames. Para realização do estudo foram coletados dados e realizados testes em 122 (cento e vinte e dois) serviços. Nestes serviços foram avaliados 134 (cento e trinta e quatro) mamógrafos convencionais, entre novembro de 2003 e dezembro de 2005, o que corresponde a aproximadamente 40% do total esperado de 330 equipamentos instalados e em uso no Estado de Minas Gerais. O trabalho foi conduzido enfocando o desempenho dos mamógrafos e processadoras, a qualidade da imagem, utilizando um simulador radiográfico que contém objetos que simulam estruturas da mama, e também um cartão dosimétrico com dosímetros termoluminescentes de Fluoreto de Lítio (TLD LiF-100) para medir a dose de entrada na superfície do simulador. Os resultados mostram que em 73 (54,5%) equipamentos não se obteve a pontuação mínima desejada para a qualidade da imagem. Dentre os resultados destaca-se o desempenho insatisfatório em 83 serviços (67%), no que ser refere ao sistema de processamento, tendo sido constatada significativa influência na qualidade final da imagem relacionado a este item. Na distribuição dos valores de kerma de entrada na superfície do simulador foram encontrados valores entre 2,41 a 16,05 mGy, com média de 7,8 mGy. Somente 17 serviços excederam o nível de referência adotado no país, de 10 mGy. Pode-se concluir que embora os níveis de radiação a que as pacientes estão expostas são aceitáveis na maioria dos serviços de mamografia, esforços devem ser feitos para garantir a qualidade da imagem. / In medical exposures, the radiological protection principles establish that doses provided to patients should be maintained as low as possible, but without reducing the quality of the image that is to be used as the main tool for diagnostic purpose. Images with definition and satisfactory contrast can be obtained under adequate geometry of the radiation beam and also with the correct choice of the receiving system and adequate processing. The breast is made of low density tissues that are formed by structures with very close densities; this increases the difficulty to get the contrast that is wanted for the image produced by the x-ray. Other factors that can influence the contrast of the mammographic image are the quality of the radiation, compression of the breast, use of gratings, film-ecran system, and the film processing. This work intended to get an overview of the mammographic services in the Minas Gerais state concerned the image quality and radiation protection, which was based on a representative sample of services. Data were collected and checks were performed in 122 services, where 134 mammography units were evaluated from November 2003 to December 2005. This amount corresponds to 40% of the total number of mammography units that are installed and used in Minas Gerais. A PMMA phantom with objects to simulate breast structures and LiF-100 thermoluminescent detectors to measure the entrance surface kerma were used to evaluate both the performance of the mammography and the processing units and the image quality. The results showed that 73 (54.5%) mammography units did not achieve the minimum acceptable performance as far the image quality. Besides, 83 (67%) services showed inadequate performance in their processing systems, which had significant influence on the image quality. Concerning the kerma values on the phantom entrance surface, they varied from 2.41 to 16.05 mGy with a mean value of 7.8 mGy; only 17 services exceeded the nationally adopted diagnostic reference level of 10 mGy. One may concluded that although the radiation levels given to the patient are acceptable in most mammographic services, efforts should be done to improve the quality of the provided image.
24

Análise dos procedimentos e critérios de implantação de feixes de raios X de referência ISO 4037 em baixas energias

Marcus Tadeu Tanuri de Figueiredo 09 August 2012 (has links)
De acordo com os princípios da proteção radiológica, as práticas que envolvem radiações ionizantes devem ser planejadas e executadas de modo que os valores de doses individuais, o número de pessoas expostas e a probabilidade de exposições acidentais sejam tão baixos quanto razoavelmente exequíveis. Para tanto, faz-se necessário que na execução da dosimetria das radiações sejam utilizados medidores confiáveis de grandezas dosimétricas. Esta confiabilidade depende não só da calibração do medidor, mas também do seu desempenho em determinadas condições de teste. A International Standardization Organization (ISO), com o objetivo de promover a padronização e a coerência metrológica internacional, estabeleceu conjuntos de feixes de raios X de referência para calibração e testes de dosímetros, cuja implantação nos laboratórios de metrologia deve atender a requisitos técnicos específicos. Em baixas energias existem especificidades que precisam ser consideradas tanto na implantação dos feixes de referência quanto na sua utilização em calibração e testes. O presente trabalho faz uma análise dos procedimentos e critérios de implantação das radiações de referência ISO 4037, em baixas energias. Foram realizados experimentos que permitiram cálculos de parâmetros de caracterização dos feixes de referência do Laboratório de Calibração de Dosímetros do Centro de Desenvolvimento da Tecnologia Nuclear (LCD/CDTN). Alternativas às metodologias usuais de determinação da camada semirredutora foram estudadas. Espectros de feixes de referência foram simulados por meio de softwares e comparados com espectros medidos experimentalmente. Condições climáticas distintas foram reproduzidas em laboratório para análise dos seus efeitos sobre os parâmetros dos feixes. Incertezas em relação às medidas de parâmetros de implantação foram avaliadas. Os feixes de baixa energia, de acordo com os critérios da norma ISO 4037, foram considerados implantados, permitindo a revisão dos valores dos coeficientes de conversão de kerma no ar para grandezas operacionais de proteção radiológica. / According to the radiological protection principles, practices involving ionizing radiation must be planned and carried out under the guarantee that the values of individual doses, the number of people exposed to radiation and the probability of accidental exposures are as low as reasonably achievable. Therefore, radiation dosimetry is required to be done with reliable instruments designed for measuring dosimetric quantities. The reliability of the dosimetry depends on both the calibration of the dosimeter and its proper performance under certain test conditions. The International Standardization Organization (ISO), in order to promote international standardization and metrological coherency, established sets of reference X-ray beams for dosimeter calibration and typing-test; they are expected to be implemented in metrology laboratories in compliance with specific technical requirements. At low energies there are specific requirements that need to be considered in both the implementation of the reference beams and their use in calibration and testing. The present study is an analysis of the procedures and criteria for ISO 4037 reference radiation implementation, at low energies. In the Dosimeter Calibration Laboratory of the Development Center of Nuclear Technology (LCD / CDTN), experiments were performed for determining the X-ray reference radiation parameters. Alternatives to the usual methods for half-value layer determination were studied. Spectra of reference beams were simulated with software and compared with experimental measurements. Different climatic conditions were reproduced in the Laboratory for analysis of its influence on the determination of the beam parameters. Uncertainties in the measurements of studied parameters were evaluated. According to the ISO 4037 criteria, the low energy X-ray beams were considered to be implemented; they allowed the determination of the conversion coefficients from air kerma to the operational radiation protection quantities.
25

Estudo de desempenho de sistemas de visualização de imagens mamográficas correlacionados com qualidade de imagem / Study of the performance of visualization mammographic systems images correlated with image quality

Danielle Soares Gomes 03 June 2014 (has links)
Para as análises de imagens mamográficas, médicos radiologistas fazem uso de monitores médicos especializados, capazes de proporcionar laudos seguros, uma vez que devem oferecem resolução adequada, níveis corretos de luminância e contraste dentro do padrão DICOM - Digital Imaging and Communications in Medicine (Comunicação de Imagens Digitais na Medicina). Este trabalho teve como objetivo avaliar a qualidade dos monitores específicos para mamografia digital, através de testes propostos pelo Report N 3 da American Association of Physicists in Medicine AAPM usando medidores calibrados de luminância (fotômetro) e padrões TG18 em testes quantitativos e qualitativos. Avaliou-se as condições de luz ambiente e outros indicadores básicos de desempenho, como, distorção geométrica, ruído, resolução, reflexão, uniformidade da luminância, o cumprimento resposta contraste de luminância para padrão DICOM e padrão anatômico das mamas. Em resposta, o teste que mais apresentou não conformidade foi à variação excessiva com o padrão de resposta contraste DICOM Grayscale Standard Display Function (GSDF), apresentando não conformidade em (100%) dos monitores analisados. Nos demais testes, todos os monitores de 5MP e o de 3MP apresentaram conformidade nos parâmetros avaliados. Em uma ação corretiva para as não conformidades, indica-se a realização de calibrações e procedimentos de verificação de controle de qualidade feitas por profissionais capacitados ou orientados. / For the analysis of mammographic images, radiologists make use of specific medical monitors, able to provide insurance reports, as they offer appropriate resolution, correct levels of luminance and contrast within the standard DICOM - Digital Imaging and Communications in Medicine (Communication Images digital in Medicine). This study aims to evaluate the quality of specific monitors for digital mammography, by testing the calibrated luminance meters (photometer) and TG18 standards in quantitative and qualitative methods proposed by Report No. 3 of American Association of Physicists in Medicine AAPM. It was evaluated the ambient light conditions and other basic performance indicators, such as, the as geometric distortion, noise, resolution, reflection, luminance uniformity, contrast luminance response compliance to DICOM standard and anatomical pattern of the breasts. The results showed that non-compliance test fails when visualizing low-contrast objects (100% of monitors analyzed) in the response pattern contrast DICOM Grayscale Standard Display Function (GSDF). For the other tests, all monitors of 5 and 3MPixel presented in agreement to the evaluated parameters. For a further corrective action for instance, non-compliance, it may be indicate to perform calibrations and verification of quality control developed by trained or oriented professionals.
26

Um portal de banco de imagens médicas distrubuído usando corba para integração de serviços de teleradiologia

Ribeiro, Leonardo Andrade January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Ciência da Computação. / Made available in DSpace on 2012-10-20T04:54:46Z (GMT). No. of bitstreams: 1 208066.pdf: 638412 bytes, checksum: c762b70508aada6ed9a0a59748b8d2c9 (MD5) / A área do diagnóstico por imagem é um dos campos da medicina mais propensos a uso da Telemedicina, porque normalmente não existe a obrigação do contato direto com o paciente pelo radiologista responsável durante a elaboração do diagnóstico. A carência de especialistas em locais distantes de grandes centros urbanos faz da Telemedicina uma importante ferramenta para melhorar os serviços de atenção à saúde. Neste trabalho é apresentado um modelo baseado em uma abordagem federada chamo Portal de Teleradiologia, para a integração de bancos de imagens médicas DICOM distribuído geograficamente. O objetivo é prover uma visão única e transparente dos dados compartilhados sem sacrificar a autonomia dos sistemas integrantes ou interferir com operações locais. Um requisito obrigatório para sistemas desta natureza é a garantia de um contexto seguro para a execução das operações. O modelo proposto prevê também a identificação única de pacientes entre as diversas bases de dados através de técnicas de relacionamento de registros. Para a implementação do protótipo do sistema foi utilizada a tecnologia de objetos distribuídos através da arquitetura CORBA.
27

Radiação ionizante da mamografia = diagnóstico ou indução ao câncer? / Ionizing radiation from mammography : diagnosis or cancer induction?

Loureiro, Clarissa Fernanda Correia Lima 18 August 2018 (has links)
Orientador: Sérgio Santos Muhlen / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-18T02:41:28Z (GMT). No. of bitstreams: 1 Loureiro_ClarissaFernandaCorreiaLima_M.pdf: 2106734 bytes, checksum: 61a0c8655393190312aacd0f345e5f92 (MD5) Previous issue date: 2011 / Resumo: Estabelecer os efeitos biológicos e níveis seguros de exposição à radiação ionizante é um objetivo a ser alcançado até os dias de hoje. Mamografia é um exame importante na detecção precoce de tumores na mama, mas desde que os genes BRCA1 e BRCA2 foram identificados como a causa principal de câncer de mama hereditário, existe uma preocupação crescente em relação à exposição às radiações ionizantes de pacientes portadoras de mutações nestes genes. A exposição poderia induzir um aumento nas mutações nos genes BRCA e outros supressores e promover o desenvolvimento do tumor nestas pacientes. Neste trabalho é proposto um estudo experimental in vitro inicial com o objetivo de determinar o nível de radiação que desencadeia mutações detectáveis nos genes BRCA, e quantificar um nível mais seguro de radiação nas mamografias de pacientes portadoras de mutações em alelo desses genes. Células de mama provenientes de uma paciente foram cultivadas e irradiadas com diferentes doses de raios X, gerados por um mamógrafo comercial. Os resultados mostram que radiações ionizantes promovem alterações mensuráveis nas células de mama cultivadas / Abstract: Establishing the biological effects and the safe level of exposure to ionizing radiation remains, so far, an objective to be reached. Mammography is an important exam in the early detection of breast tumors, but since the genes BRCA1 and BRCA2 were identified as a main cause of hereditary breast cancer, there is growing concern of exposing patients carrying those mutations to ionizing radiation. It could increase mutations in these genes and other suppressors, and promote the development of tumor in those patients. In this study we propose an in vitro initial experiment aiming to determine the radiation trigger level for detectable mutations in genes BRCA, and thus a safer level of radiation due to mammography for patients carrying a mutated allele of the genes BRCA1 or BRCA2. Breast cells from one patient were cultivated and irradiated with different doses of X-rays generated by commercial mammography equipment. The results have shown that exposition to ionizing radiation promotes measurable alterations in breast cell grown / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
28

Análise de parâmetros e controle da qualidade de sistemas de radiologia computadorizada para mamografia / Analyis of parameters and quality control in computed radiography systems for mammography

Frederico Ladeia Alvarenga 29 August 2008 (has links)
Nenhuma / O desenvolvimento e a consolidação de novas tecnologias na radiologia vêm se constituindo em uma estratégia permanente das empresas, uma vez que resulta em ganhos de produtividade, qualidade dos produtos e serviços, redução de custos, conscientização ambiental, eliminação de desperdícios, melhoria em atendimento e diagnósticos para os pacientes. O programa de controle da qualidade em mamografia é um instrumento para o gerenciamento da qualidade dos serviços que são oferecidos à população. A radiografia computadorizada (CR) em mamografia surge como uma importante ferramenta nas ações sistematizadas de controle do câncer de mama, na detecção precoce através de programas de rastreamento de segmentos populacionais, com exames periódicos. Para que se tenham mamografias de qualidade ótima na detecção do câncer de mama é necessário seguir critérios de qualidade da imagem e desempenho dos equipamentos. Os sistemas de radiografia computadorizada (CR) constituem um método eficiente e econômico de captura e conversão de radiografia em formato digital. Desde que as soluções digitais em mamografia vêm sendo utilizadas comercialmente, mostrou-se evidente que os sistemas de avaliação dos métodos analógicos não são apropriados para as tecnologias digitais. Por se tratar de um sistema novo no processo de aquisição de imagens médicas, ainda não se tem um método definido de avaliação estabelecido pelos órgãos reguladores nacionais. Os ensaios foram realizados no Laboratório de Calibração e Dosimetria do Centro de Desenvolvimento da Tecnologia Nuclear onde foi possível avaliar a cadeia da formação da imagem e parâmetros de qualidade da imagem como: contraste, resolução espacial, ruído, densidade ótica, razão sinal ruído, razão sinal contraste, distorção, artefatos e processamento. Esses parâmetros influenciam na capacidade de interpretação e visualização da imagem radiográfica, sendo estes determinantes para a tomada de decisão do diagnostico final. O propósito deste trabalho é o de analise de parâmetros e controle da qualidade de sistemas de radiologia computadorizada para mamografia a fim de apresentar indicadores que refletem a exposição à radiação em um detetor de imagem. O resultado final dos testes de caracterização do sistema digital avaliado foi satisfatório em todos os aspectos relativos à metodologia aplicada para avaliação dos testes, comprovando assim os benefícios dos sistemas digitais de aquisição de imagens médicas. O trabalho sugere um modelo de metodologia para avaliação do sistema de radiografia computadorizada em mamografia. / The development and the consolidation of new technologies in radiology became a permanent strategy of companies since they contribute to the increase of productivity, the upgrade of the quality of products and services, reduction of costs, environmental consciousness, elimination of waste and improvement of the diagnosis. The quality control program for mammography is an instrument for the management of the quality of services provided to the population. The Computed Radiography (CR) in mammography appears to be an important tool in the systematic actions for controlling the breast cancer; it also has an important role in the early detection through screening programs of population segments by periodic exams. Good mammography images are achieved if the criteria for image quality and equipment performance are complied with standards. The Computed Radiography systems are an efficient and economical method of capture and conversion of the diagnostic image to digital format. Since digital solutions in mammography have been used, it became evident that evaluation systems of analogical methods are not adequate to digital technologies. The CR is a new system for the acquisition process of medical images; therefore there are not yet standards with an established quality control evaluation method provided by national regulatory authority. Measurements were carried out in a CR of the Dosimetry and Calibration Laboratory of the Development Center of Nuclear Technology; it was possible to evaluate the image formation chain and image quality parameters as contrast, spatial resolution, noise, optical density, signal-noise ratio, signal-contrast ratio, distortion, test objects and processing method. The visualization and interpretation ability of the radiographic image are highly influenced by those parameters; they are determinant for taking decision of the final diagnostic. The purpose of this work was to analyze the image parameters and the quality control procedure of CR systems for mammography; indicators that reflect the radiation exposure in an image detector were recommended. The final result of the characterization tests in this digital system was statistically significant relative to all aspects to the applied methodology for tests evaluation, proving the benefits of this digital system for acquisition of medical images. This work suggests a methodology model for evaluating the computed radiography systems used for mammography purposes.
29

DOSE GLANDULAR E CONTROLE DE QUALIDADE DA IMAGEM EM SERVIÇOS DE MAMOGRAFIA COM SISTEMA DE RADIOGRAFIA COMPUTADORIZADA / GLANDULAR DOSE AND IMAGE QUALITY CONTROL IN MAMMOGRAPHY FACILITIES WITH COMPUTED RADIOGRAPHY SYSTEM

Marcelino Vicente de Almeida Dantas 05 March 2010 (has links)
O câncer de mama é o câncer mais comum entre as mulheres, e a detecção precoce é crucial para seu diagnóstico e tratamento. Atualmente, o método mais efetivo para a detecção precoce do câncer de mama é a mamografia, onde o sistema tela/filme é o padrão ouro. Entretanto, apesar do sistema tela/filme ter sido melhorado e otimizado ao longo dos anos, para imagens da mama, existem algumas limitações críticas, incluindo faixa de exposição, artefatos da imagem, problemas no processamento dos filmes, e inflexibilidade em processamento das imagens e gerenciamento dos filmes. Nos últimos anos, a mamografia digital tem sido introduzida nos programas de rastreamento do câncer, com o sistema tela/filme sendo gradualmente substituído. A radiografia computadorizada (computed radiography - CR), comumente conhecida também como photostimulable phosphor (PSP) ou storage phosphor, emprega placas de imagem reutilizáveis e computadores e programas associados para adquirir e mostrar as radiografias de projeção digital. Neste trabalho foi testado um modelo de protocolo para a realização do controle de qualidade de imagem e de avaliação de doses glandular em 19 instituições com sistemas de radiografia computadorizada em mamografia. O protocolo foi validado através de testes feitos no Laboratório de Radioproteção Aplicada à Mamografia (LARAM) do Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). A avaliação visual da qualidade da imagem do phantom CDMAM mostrou que 53% dos serviços conseguiram produzir imagens de ótima qualidade. Já a avaliação automatizada da qualidade da imagem, através do software de análise cdcom.exe, mostrou que 57% das imagens eram de boa qualidade. O teste da linearidade do detector mostrou que a resposta do sistema CR é bastante linear, onde 95% dos serviços / Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. However, even though SF combinations have been improved and optimized over the years for breast imaging, there are some critical limitations, including a narrow exposure range, image artifacts, film processing problems, and inflexibility in image processing and film management. In recent years, digital mammography has been introduced in cancer screening programmes with the screen/film techniques gradually being phased out. Computed radiography (CR), also commonly known as photostimulable phosphor (PSP) imaging or storage phosphor, employs reusable imaging plates and associated hardware and software to acquire and to display digital projection radiographs. In this work, a protocol model was tested for performing image quality control and average glandular dose (AGD) evaluation in 19 institutions with computed radiography systems for mammography. The protocol was validated through tests at the Laboratório de Radioproteção Aplicada à Mamografia (LARAM) from the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). The image quality visual evaluation of CDMAM phantom showed that 53% of the facilities were able to produce images of excellent quality. Furthermore, the automated evaluation of image quality, using the analyze software cdcom.exe, showed that 57% of the images were considered to be of good quality. The detector linearity test showed that the CR response is very linear, where 95% of facilities evaluated were considered to be compliant. For the image noise was found that only 20% of facilities are in agreement with the parameters established for this test.
30

Estudo do campo de radiação neutrônica em torno do cíclotron GE PETtrace-8 de 16,5 MeV do CDTN / Study of the neutron radiation field around the GE-PETtrace-8 cyclotron do CDTN

Adriana Márcia Guimarães Rocha 03 July 2012 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / Os radionuclídeos utilizados na tomografia por emissão de posítrons (PET) são produzidos utilizando um acelerador cíclotron. Os nêutrons produzidos durante a operação do cíclotron contribuem para exposição direta ou indireta dos Indivíduos Ocupacionalmente Expostos (IOEs), devido ao aumento da radiação de fundo da casamata. Além disso, há um aumento nas emissões de gases radioativos provenientes da ativação dos elementos do ar dentro da casamata, que quando liberados constitui um problema para radioproteção dos indivíduos do público. Dos vários métodos utilizados para caracterizar o espectro neutrônico, o espectrômetro de multiesferas de Bonner (EB) é um dos sistemas espectrométricos mais utilizados. Neste trabalho foi utilizado o sistema EB com detectores termoluminescentes (TL), do tipo TLD600 e TLD700 como detector de nêutrons, para medir os espectros de energia de nêutrons em quatro pontos no interior da casamata do cíclotron GE PETtrace-8 do Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). Foram realizadas medidas em quatro pontos em torno do cíclotron. Os espectros de nêutrons foram desdobrados utilizando os códigos BUMS, NSDUAZ e BUNKIUT e os resultados convertidos em equivalente de dose ambiente H*(10). Considerando o termo fonte de radiação fornecido pelo fabricante do cíclotron, pôde-se constatar a grande influência dos nêutrons de recuo nos espectros de energia encontrados em todos os pontos. Houve uma boa concordância nos espectros de nêutrons obtidos, utilizando os códigos BUNKIUT (com espectros iniciais retangular e Maxwelliano) e NSDUAZ. Os valores de taxa de fluência encontrados no presente trabalho foram da mesma magnitude dos valores reportados na literatura e são coerentes com os obtidos por cálculos téóricos utilizando o termo fonte de radiação disponibilizado pelo fabricante. Com relação aos valores de equivalente de dose ambiente, as taxas horárias por &#61549;A (microampère) variaram de aproximadamente 67 mSv/h a 936 mSv/h . Para uma corrente típica de 40 &#61549;A, esses valores são próximos de 2,7 Sv/h a 37 Sv/h, valores da mesma ordem dos reportados na literatura. A metodologia empregada para a caracterização do campo de radiação em torno do cíclotron do CDTN mostrou-se adequada e pode ser utilizada em mais pontos da casamata, de maneira a descrever melhor o espectro e, consequentemente, estimar o equivalente de dose ambiente. / The radionuclides used in positron emission tomography (PET) are generally produced using a cyclotron accelerator. The operation of the cyclotron produces an undesirable neutron radiation field. The knowledge of the neutron radiation field around not-self-shielded PET cyclotrons is an important issue for optimization of radiation protection of the workers and individuals of the public. For the workers, neutrons contribute not only for immediate radiation exposure as for long-term exposure due to activation of cyclotron components and the concrete in the bunker walls. For the individuals of the public the main concern is the dispersal of radioactive gases produced by activation of the air inside the cyclotron vault. The multisphere system, or Bonner sphere spectrometer (BSS), has been widely used to measure neutron spectrum. The substitution of the active detectors of the BSS system by thermoluminescent detectors (specifically TLD-600 and TLD-700 pairs) has become a reliable procedure in spectrometry of high intensity mixed radiation field. In this study we utilized the BSS system with TLD600 and TLD700 to measure the energy spectra of neutrons at four points inside the bunker of the cyclotron GE PETtrace-8 of the Development Centre of Nuclear Technology (CDTN). Four points inside the bunker of the cyclotron were studied. The neutron spectra were unfolded using codes BUMS, NSDUAZ e BUNKIUT and the results converted to ambient dose equivalent H*(10). Considering the source-term of radiation provided by the manufacturer of the cyclotron, we could see the great influence of room return effect in energy spectra at all points. The values of total fluence rates for all points have the same magnitudes of values reported in the literature and are consistent with those obtained by theoretical calculations using the source-term of radiation provided by the manufacturer of the cyclotron. The ambient equivalent dose rates for 1 &#61549;A ranged from about 67 mSv/h to 936 mSv/h. For a typical 40 &#61549;A typical current these values were 2.7 Sv/h and 37 Sv/h. These values are of the same order than the reported in the literature. The methodology utilized in this study to characterize the neutron radiation field around the CDTN cyclotron proved to be adequate and can be used in more points inside the bunker in order to better describe the spectrum and thereby estimate the ambient dose equivalent.

Page generated in 0.0191 seconds