• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1438
  • 201
  • 65
  • 65
  • 65
  • 64
  • 40
  • 15
  • 15
  • 15
  • 11
  • 10
  • 7
  • 2
  • 2
  • Tagged with
  • 1671
  • 625
  • 519
  • 402
  • 369
  • 313
  • 276
  • 274
  • 234
  • 210
  • 184
  • 163
  • 136
  • 136
  • 119
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
401

Avaliação de dois protocolos restauradores atraumáticos em molares decíduos

Demarchi, Karine Medeiros 28 February 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2018. / Submitted by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-16T19:02:09Z No. of bitstreams: 1 2018_KarineMedeirosDemarchi.pdf: 1829607 bytes, checksum: 0b4cf4c4cd4f9a712b3b5e2e1f5caf59 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T20:37:01Z (GMT) No. of bitstreams: 1 2018_KarineMedeirosDemarchi.pdf: 1829607 bytes, checksum: 0b4cf4c4cd4f9a712b3b5e2e1f5caf59 (MD5) / Made available in DSpace on 2018-07-20T20:37:01Z (GMT). No. of bitstreams: 1 2018_KarineMedeirosDemarchi.pdf: 1829607 bytes, checksum: 0b4cf4c4cd4f9a712b3b5e2e1f5caf59 (MD5) Previous issue date: 2018-07-16 / Introdução: O Tratamento Restaurador Atraumático (ART) compreende medidas preventivas, terapêuticas e restauradoras para a prevenção e manejo da doença cárie. Nos últimos anos, a melhoria dos materiais restauradores mais indicados para a técnica (cimento de ionômero de vidro de alta viscosidade, CIV) levou a bons resultados, porém ainda com espaço para desenvolvimentos. Em virtude de limitações dos CIV, novos materiais restauradores adesivos, como as resinas compostas bulk fill utilizadas juntamente com sistemas adesivos autocondicionantes, passam a se apresentar como alternativas para uso na técnica ART. Objetivo: Comparar resultados imediatos (tempo e satisfação do paciente) de restaurações ART em lesões cariosas de rasa e média profundidades utilizando uma resina composta bulk fill associada a um sistema adesivo autocondicionante – protocolo BF, ou um cimento de ionômero de vidro de alta viscosidade – protocolo CIV. Métodos: 155 crianças entre 7-8 anos de idade, com lesões cariosas de extensão radiográfica não invadindo a metade interna da dentina em dentes vitais e assintomáticos, foram randomizadas nos protocolos BF ou CIV. 270 restaurações (BF, n=78 e CIV, n=77) foram realizadas por dois dentistas treinados. O acesso às lesões e a remoção de tecido cariado foram realizados apenas com instrumentos manuais. As cavidades foram restauradas com resina composta bulk fill (BF, Filtek Bulk Fill Posterior, 3M ESPE) ou com cimento de ionômero de vidro de alta viscosidade (CIV, Equia Forte, GC). Foram registrados dados imediatos pós-tratamento relacionados ao tempo de execução e à satisfação dos pacientes (escala de face de Likert de 5 pontos). Os dados foram analisados estatisticamente por modelos lineares generalizados mistos. Resultados: Não houve diferença estatisticamente significativa entre os tempos de tratamento [Média (95% CI), BF: 357,06s (330,96-383,15) e CIV: 332,26 (313,57-350,94). A satisfação dos pacientes pós-tratamento foi elevada (pontuação mediana 1: muito satisfeito) para ambos os protocolos, sem diferença estatisticamente significativa entre eles (p=0,653). Conclusão: Não houve diferenças estatisticamente significativas entre os protocolos BF e CIV no que diz respeito ao tempo de tratamento e satisfação dos pacientes. A longevidade das restaurações e possíveis complicações serão analisadas nos períodos de acompanhamento do estudo clínico randomizado. / Background: The Atraumatic Restorative Treatment (ART) comprises preventive, therapeutic and restorative measures for the prevention of dental caries. In recent years, an improvement in the restorative materials most suitable for the technique (glass ionomer cement, GIC) has led to good results, although there is room for improvement. Due to limitations of the GIC, other adhesive restorative materials, such as bulk fill composite resins along with self-etching adhesive systems, are presented as alternatives for use within the ART technique. Aim: To compare the immediate results of ART restorations in shallow and medium depth carious lesions using a composite bulk-fill resin associated with a self-etching system - BF protocol, or a high viscosity glass ionomer cement - GIC protocol. Methods: 155 children between 7-8 years of age, with non-invasive radiographic extension carious lesions of the inner half of the dentin in vital and asymptomatic teeth, were randomized in the BF or GIC protocols. 270 restorations (BF, n = 78 and GIC, n = 77) were performed by two trained dentists. Access to lesions and removal of carious tissue were performed only with manual instruments (ART). The cavities were restored with bulk fill composite (BF, Filtek Bulk Fill Posterior, 3M ESPE) or high viscosity glass ionomer cement (CIV, Equia Forte, GC). Immediate posttreatment data related to time of procedure and patient satisfaction were recorded (5-point Likert face scale). The data were statistically analyzed by generalized linear mixed models. Results: There were no statistically significant differences between treatment time [Mean (95% CI) BF: 357,06s (330.96 to 383.15) and CIV: 332.26 (313.57 to 350.94). Post-treatment patient satisfaction was high (median score 1: very satisfied) for both protocols, with no statistically significant difference between them (p = 0.653). Conclusion: There were no statistically significant differences between the BF and CIV protocols regarding the time of treatment and patient satisfaction. The longevity of the restorations and possible complications will be analyzed during the follow-up periods of the randomized clinical trial.
402

Emprego da resina ureia-formaldeído na produção de adsorventes catiônicos para desmineralização d'água / Use of urea-formaldehyde resin in the production of cationic adsorbents for water demineratization

Costa, Karla Andressa Velho [UNESP] 25 February 2015 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:26:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-25. Added 1 bitstream(s) on 2018-07-27T18:30:33Z : No. of bitstreams: 1 000870770.pdf: 1723056 bytes, checksum: bc92f51f7e5e15cc142e9a46dde9a954 (MD5) / Resina uréica ou qualquer resina da classe de sintéticos são obtidas por uma combinação química de ureia e formaldeído. Esas resinas são usadas principalmente como adesivos para a colagem de madeira compensada, de aglomerado e outros produtos de madeira estruturada. Na produção industrial, resinas de ureia são sintetizadas pela condensação de formaldeído e ureia em uma solução aquosa, usando amônia como catalisador alcalino. Este trabalho teve como objetivo sintetizar adsorventes com propriedades catiônicas empregando a resina ureia-formaldeído como suporte, com aplicação na desmineralização de água. Foi estudada a resina ureia-formaldeído com os grupos catiônicos, ácido p-aminobenzóico, ácido sulfanílico aminoacético com os metais, Hg+2, Pb2+, Cd+2, Cu2+ e Zn+2. De acordo com os testes realizados percebeu-se que as resinas tiveram comportamento eficiente quando submetidas à adsorção dos metais estudados nesse trabalho, quando utilizadas soluções com concentrações mais elevadas. Já em soluções contendo baixas concentrações, todos os metais apresentaram adsorção insatisfatória na superfície das resinas imobilizadas com os grupos orgânicos. Os valores obtidos dos teores de nitrogênio determinados nos adsorventes resina UF, resina UF + APABZ, UF + ASF e UF + AA foram 15,49%, 15,60%, 21,24%, 45,06% e o número de mols do grupo orgânico/grama do adsorvente, foram 5,1x10-5, 4,1x10-3 e 2,1x10-2 respectivamente / Urea resin or synthetic resin class are obtained by a chemical combination of urea and formaldehyde. These resins are mainly used as adhesive for wood glue phywood, particleboard and other wood products structured. In the industrial production of urea resins are synthesized by, considensing urea and formaldehyde in an aqueous solution by using ammonia as alkali catalyst. This study aimed to synthesize adsorbents with cationic using area-formaldehyde resins was studied with cationic groups, p-aminobenzoic acid, sulfanilic acid and aminoacetic acid with metals, Hg+2, Pb+2, Cd+2, Cu+2 and Zn+2. According to the tests we noticed that the resins were efficient behavior when subjected to the adsorption of the metals studied in this work, when used solutions with higher concentrations. Already in solutions containing low concentrations, all metals showed poor adsorption on the surface of immobilized resins with organic groups. The values obtained from nitrogen levels set in adsorbent resin UF, UF resin + APABZ, UF + ASF and UF = AA were 15.49%, 15.60%, 21.24%, 45,06% and the number of moles the organic group/gran of adsorbent were 5,1x10-5, 4,1x10-3 and 2,1x10-2 respectively
403

Influência da adição de reforço e ciclagem mecânica na resistência ao impacto de resinas para base e para reembasamento imediato /

Perez, Luciano Elias da Cruz. January 2009 (has links)
Orientador: Ana Lúcia Machado / Coorientador: Sebastião Vicente Canevarolo Junior / Banca: Maria da Gloria Chiarello de Mattos / Banca: Sicknan Soares Rocha / Banca: Marco Antonio Compagnoni / Banca: Ana Claúdia Pavarina / Resumo: Este estudo avaliou o efeito da adição de reforço e ciclagem mecânica sobre a resistência ao impacto, por meio dos testes Charpy (C) e queda livre de dardo (QL), para resinas de base e para reembasamento imediato. Para o teste C, corpos-de-prova (60x6x2 mm) foram confeccionados com as resinas Lucitone 550 (L) e Vipi Wave (V) e reembasados (2 mm) com o mesmo material (L/L ou V/V) ou com as resinas para reembasamento imediato Tokuyama Rebase II (T) e Ufi Gel Hard (U). Corpos-de-prova puros de L, V, T e U (60x6x4 mm) também foram confeccionados para se determinar a resistência ao impacto dessas resinas. Para a avaliação da adição de reforço, foi adicionado ao pó das resinas reembasadoras 5%, em massa, do reforço de floco de vidro "glass flake" (UR, TR, L/UR, L/TR, V/UR, V/TR). 320 corpos-de-prova foram confeccionados, sendo 20 para cada condição experimental. Metade desses foi submetida à ciclagem mecânica (10.000 ciclos) com freqüência de 5 Hz (LC, VC, TC, UC, URC, TRC, L/URC, L/TRC, V/URC, V/TRC). Um entalhe, em forma de V foi realizado na largura, na superfície correspondente ao material reembasador, com profundidade de 0,8 mm, permanecendo 3,2 mm de material intacto. O teste foi realizado com pêndulo de 0,5 J e distância de 50 mm entre os suportes. Os resultados (kJ/ m2) foram analisados utilizando-se ANOVA e teste de Dunnet C (α = .05). Não houve diferenças estatisticamente significantes entre as médias de resistência ao impacto das condições L, L/L, V, V/V, LC, L/LC, VC e V/VC. As condições experimentais relativas às resinas autopolimerizáveis U, T, UC, TC, UR, TR e TRC foram estatisticamente iguais entre si. Além disso, URC também foi estatisticamente igual a U, T, UC, TC, TR e TRC, porém, maior do que UR. Não houve diferença significativa (P>.05) entre as médias de resistência ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of the addition reinforcement and cyclic loading on the resistance to impact of Charpy tests (C) and free falling-dart (FD) for the denture base resins and reline materials. To test the C, bars (60x6x2 mm) were prepared with the resins Lucitone 550 (L) and Vipi Wave (V) and relined (2 mm) with the same material (L / L or V / V) or with relining resins Tokuyama Rebase II (T) and UFI Gel Hard (U). Specimens pure of L, V, T and U (60x6x4 mm) were also made to determine the impact resistance of these resins. For the evaluation of the addition of reinforcement, was added to the powder of the relining resins 5% by weight of the glass flake "glass flake" (UR, TR, L / UR, L / TR, V / UR, V / TR). 320 specimens were made, 20 for each experimental condition. Half of these were subjected to cyclic loading (10,000 cycles) with a frequency of 5 Hz (LC, VC, TC, UC, URC, TRC, L / URC, L / TRC, V / URC, V / TRC). A notch in the form of V was carried out in width, the area corresponding to the relining material with depth of 0.8 mm, 3.2 mm of material remained intact. The test was conducted with pendulum of 0.5 J and 50 mm distance between the supports. The results (kJ/ m2) were analyzed using the ANOVA and Dunnet C test (α = .05). No significant differences were noted among the mean impact values of L, L / L, V, V / V, LC, L / LC, VC and V / VC. The experimental conditions for relining resins U, T, UC, TC, UR, TR and TRC were statistically equal between themselves. In addition, URC was statistically equal to U, T, UC, TC, TR and TRC, however, higher than UR. No significant differences were noted (P> .05) mong the mean impact values of L/ U, V/ U, L/ UC, V/ UC, L/URC and V/ URC. These conditions had values of resistance to impact significantly lower than those of the resin tested pure L and T (P <.05). There was... (Complete abstract click electronic access below) / Doutor
404

Influência do processamento de próteses totais superiores em função da profundidade do palato : análise da movimentação dos dentes artificiais por computação gráfica /

Vedovatto, Eduardo. January 2005 (has links)
Orientador: Humberto Gennari Filho / Banca: Marcelo Coelho Goiato / Banca: Valdir Antonio Muglia / Resumo: Em função do relacionamento existente entre a profundidade do palato e as alterações das bases de resina acrílica, esse trabalho investigou a movimentação dos dentes que ocorrem quando próteses totais são processadas com diferentes materiais e técnicas e a relação com o formato do palato. Foram confeccionadas vinte e oito réplicas de próteses totais sobre modelos maxilares com palato raso e vinte e oito réplicas para o palato profundo, idênticas quanto ao enceramento e posicionamento dos dentes. As próteses foram divididas em oito grupos com sete espécimes cada, de acordo com o tipo de resina utilizada, o material utilizado para inclusão em mufla e o tipo de palato. Foram demarcados pontos sobre os dentes que serviram de referência para as mensurações através do software AutoCAD 2005. As mensurações foram realizadas em dois estágios: após o enceramento das próteses e após a demuflagem (não separadas do modelo). Os resultados foram submetidos à análise de variância e as comparações ao teste de Tukey com probabilidade de 5%. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos estudados, porém quando a análise ocorreu num contexto geral, diferença estatisticamente significativa foi observada para as variáveis, formato de palato e material de inclusão. Baseado nos resultados pode-se concluir que: o formato do palato influencia nas alterações dos dentes artificiais; o palato profundo sofreu alterações dentais significantemente inferiores que o palato raso; as próteses incluídas com silicone apresentaram alterações significantemente superiores às incluídas com gesso; o tipo de resina utilizada não acarretou em alterações estatísticamente significantes entre si; a região posterior das próteses apresentou maiores alterações em relação à região anterior. / Abstract: About the relationship between the palate depth and the changes in acrylic resins base-plate, this work investigate the teeth movement that occurs when the complete dentures were processed by different materials, techniques and its relation to the palatal form. Twenty eight samples of complete dentures in maxillary cast with shallow palate form and twenty eight with deep palate form were constructed for the study. The samples presented similarities in the artificial teeth position. This prosthesis were divided in eight groups with seven specimens each, in agreement with the resin type for inclusion, the type of material used in the covering and the type of the palate depth. Points were demarcated on the teeth, which served as reference for the measurements of the segments (among the teeth), through software AutoCAD 2005. The measurements are accomplished in two moments: after the waxed and after the desflasking (not descasting). The results were submitted to the analysis of variance and comparisons to the Tukeyþs test with probability of 5%. The results showed no statistical significantly differences between the groups, but when the variables were study in global context difference were observed for the palatal form and covering materials. Based on the results conclude that: the palatal form influence on the changes of teeth position. The deep palate showed alterations significantly inferior that presented for the shallow palate. The silicon used for the covering results in greater alterations in relation to the stone mold. The type of resin not differs in the alterations of teeth position (not significantly). The change of teeth position was greater in the posterior region compares to the anterior region of the prosthesis. / Mestre
405

Influência de métodos de limpeza de próteses sobre a rugosidade, dureza e quantificação de candida albicans de uma resina para reembasamento /

Izumida, Fernanda Emiko. January 2009 (has links)
Orientador: Eunice Terezinha Giampaolo / Banca: Ana Cláudia Pavarina / Banca: Renata Cristina Silveira Rodrigues Ferracioli / Resumo: As características superficiais dos materiais utilizados em próteses podem influenciar na retenção de microrganismos. Além disso, a higienização das próteses também pode interferir na superfície e consequentemente na proliferação de microrganismos. Dessa forma, o presente estudo avaliou o efeito da higienização mecânica com escova/sabão de coco e escova/dentifrício e duas soluções de limpeza química (perborato de sódio a 3,78% e clorexidina a 2%) bem como suas interações, na rugosidade superficial, dureza e quantificação de Candida albicans do reembasador rígido Tokuyama Rebase Fast II em diferentes intervalos de tempo. Foram confeccionados 150 corpos-de-prova, a partir de uma matriz metálica (40X10X2mm), os quais foram divididos aleatoriamente em 10 grupos experimentais (n=15), de acordo com a interação das soluções de escovação e imersão: controle - C; água-água - A; água-perborato - APb; águaclorexidina - ACh; sabão-água - SA; sabão-perborato - SPb; sabão-clorexidina - SCh; dentifrício-água - DA; dentifrício-perborato - DPb e dentifrício-clorexidina - DCh. Os testes de escovação foram realizados em uma máquina de ensaios (30 ciclos diários) e as imersões foram realizadas por 10 minutos ao dia. As análises de rugosidade superficial (Ra) e de dureza Knopp foram realizadas inicialmente, após 7, 15, 30, 90, 180, 270 e 365 dias. A quantificação microbiológica foi realizada após todo o período de análise da rugosidade e da dureza em todos os grupos experimentais. Os dados obtidos foram analisados por análise de variância, seguida pelo teste de Tukey, ao nível de significância de 5%, para rugosidade e dureza. Para a quantificação de C. albicans foi realizada análise de variância de 2 fatores. Os resultados indicaram a rugosidade superficial não foi alterada (p>0,05) para os grupos C, APb, SCh e DA em todo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The surface characteristics of intraoral hard surfaces can influence plaque retention. Furthermore, denture cleansers can interfere on surface and increase microorganism proliferation. Thus, the aim of this study was to evaluate the effect of mechanical cleansing (toothbrush/coconut soap and toothbrush/dentifrice), two chemical solutions (sodium perborate 3,78% and chlorhexidine 2%) and its interactions on the surface roughness, hardness and Candida albicans quantification of the reline resin Tokuyama Rebase Fast II in different time intervals. One hundred fifty specimens were made using a stainless steel mold (40X10X2mm) and divided into 10 groups (n=15): control - C; water-water - A; water-perborate - APb; water-chlorhexidine - ACh; soap-water - SA; soapperborate - SPb; soap-chlorhexidine - SCh; dentifrice-water - DA; dentifriceperborate - DPb e dentifrice-chlorhexidine - DCh. The toothbrush test was performed in a toothbrush abrasion machine using 30 strokes per day and the immersions were made for 10 minutes per day. Surface roughness (Ra) and Knoop hardness of the specimens were evaluated initial - baseline, and after 7, 15, 30, 90, 180, 270 and 365 days. Candida albicans quantification was performed after all surface roughness and hardness mensuration period. The results were analyzed by analysis of variance (ANOVA) followed by Tukey's test for surface roughness and hardness. For C. albicans quantification, the data was analyzed y analysis of variance (ANOVA). The analyses were conducted at 95% confidence level. The results showed that the surface roughness of groups C, APb, SCh e DA were not affected for all evaluation periods. Treaments of groups A, ACh, SPb, DPb e SA promoted increase on mean roughness values until 30 days, compared to other periods. Lower roughness values were obtained to DCh and DPb compared to ACh, A, SA, APb or SCh for ... (Complete abstract click electronic access below) / Mestre
406

Reciclagem e caracterização de fibra de carbono presente em compósito de resina epóxi / RECYCLING OF FIBER CARBON FROM EPOXY RESIN AND FIBER CARBON COMPOSITES

Rodrigues, Gleice Guevara Matielli 18 April 2013 (has links)
Made available in DSpace on 2016-06-02T19:19:59Z (GMT). No. of bitstreams: 1 RODRIGUES_Gleice_2013.pdf: 5731600 bytes, checksum: 0c33d0f87e96e5d840cc87af26f596f7 (MD5) Previous issue date: 2013-04-18 / Carbon fiber reinforced epoxy composites are engineering materials whose are used in a wide range of applications in industries such as automotive, aerospace and sporting goods due to the properties of these composites as strength, durability, low weight and low cost. There are in the literature studies of various methods of recycling carbon fiber at the end of life from parts made with this material. This work reports a study of the polyacrylonitrile carbon fiber reinforced polymer recycling from diglicicil epoxy ether of bisphenol A composite. Initial studies were aimed at finding the best condition to remove the polymer matrix and thereby recover the carbon fiber by heat treatment in a muffle furnace. The matrix was removed at 450°C without degradation of the carbon fiber at 2 hours. The removal of the meanly volatile substances was verified with the Gas Chromatography analysis. The carbon fiber was incorporated randomly in the polyurethane matrix without chemical pre-treatment. The confirmation of the removal of the resin carbon fiber was obtained through the Scanning Electron Microscopy (SEM) and Fourier Transform Infrared Spectroscopy (FTIR). The characterization of the carbon fiber reinforced polyurethane composite was performed using the techniques: Thermogravimetric Analysis (TGA), Dynamic Mechanical Analysis (DMA) and FTIR. Thus, it was observed that the carbon fiber reinforced polyurethane at 2 % and 3% showed improvement in the mechanical properties since the storage modulus value was 3 and 4 times more than pure PU, respectively. Moreover, the glass transition temperature was more than 140°C for the composite polyurethane/carbon fiber and 110°C for the PU pure. / Os compósitos de polímeros termorrígidos reforçados com fibra de carbono apresentam um crescente uso em diversas aplicações na indústria automotiva, aeronáutica e materiais esportivos devido às importantes propriedades desses polímeros como baixa densidade, resistência à corrosão e custo reduzido. Dessa forma, é possível encontrar na literatura diversos estudos de recuperação da fibra de carbono a partir de compósitos de resina epóxi. Nesse trabalho, estudouse a reciclagem de fibra de carbono de base de poliacrilonitrila a partir de compósito de resina epóxi diglicicil éter do bisfenol A. Dessa forma, a primeira parte do estudo teve como objetivo encontrar a melhor condição para remover a matriz polimérica e com isso recuperar a fibra de carbono através de tratamento térmico em mufla. Realizou-se o tratamento térmico do compósito em várias temperaturas, e a condição ideal foi obtida a 450°C por 2 horas, uma vez que toda resina foi removida sem degradar a fibra. A eliminação dos principais voláteis durante o tratamento térmico foi acompanhada com o uso de cromatografia gasosa. A segunda etapa do trabalho consistiu em utilizar a fibra de carbono recuperada como material de reforço de poliuretana. A fibra de carbono foi incorporada aleatoriamente na matriz polimérica sem tratamento químico. A confirmação da remoção da resina da fibra de carbono foi obtida através dos ensaios de microscopia eletrônica de varredura (MEV) e Microscopia na Região do Infravermelho com Transformada de Fourier (FTIR). Realizou-se a caracterização da poliuretana reforçada com fibra de carbono através da Termogravimetria (TG), da Análise Dinâmico Mecânica (DMA ou DMTA) e FTIR. Com isso, observou-se que as amostras de poliuretana reforçadas com fibra de carbono a 2% e a 3% em massa apresentaram um módulo de armazenamento três e quatro vezes maiores do que o da matriz pura, respectivamente. Além disso, observou-se que a transição vítrea (Tg) do compósito de PU e fibra de carbono foi maior que 140°C enquanto que a PU sem fibras apresentou Tg de aproximadamente 110°C.
407

Avaliação de LEDs de alta intensidade quanto à eficiência de polimerização de resina composta e variação de temperatura na dentina bovina

Mollica, Fernanda Brandão [UNESP] 29 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-29Bitstream added on 2014-06-13T20:31:06Z : No. of bitstreams: 1 mollica_fb_me_sjc.pdf: 859430 bytes, checksum: 9995882b109a407d775d587ef3cb2f1c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve por objetivo avaliar a eficiência de polimerização de uma resina composta (RC) e a variação de temperatura na dentina bovina, empregando aparelhos de Diodo Emissor de Luz (LED) de alta intensidade em comparação a um aparelho de Quartzo-Halogênio-Tungstênio (QTH). Os aparelhos utilizados foram: Curing Light XL 3000 (3M, 600 mW/cm2), LED SmartLite PS (Dentsply, 950 mW/cm2) e LED Radii (SDI, 1400 mW/cm2) e a RC, a Esthet X (Dentsply). Para o teste de microdureza Vickers, foram confeccionados 84 corpos-de-prova (2 mm x 5 mm) em matriz de teflon bipartida, variando-se o tempo de exposição em 10, 20 e 40 s, sendo que o aparelho XL 3000 foi utilizado para o grupo controle apenas pelo tempo de 40 s. Após 24 h, realizou-se o teste de microdureza no topo e na base dos corpos-de-prova com carga de 50 g e duração de 15 s. Para a medida da variação de temperatura ocasionada pelos aparelhos, foram utilizadas 45 fatias de dentina bovina de 0,7 mm de espessura e termopar tipo T conectado a um sistema de aquisição de dados ADS 2000 IP (Lynx Tecnologia). As fatias foram divididas em três grupos, sendo a variação de temperatura medida em três etapas: 1) durante a fotopolimerização do adesivo (10 s); 2) durante a fotopolimerização da RC (40 s) e 3) após 24 h (40 s). Os valores de microdureza do topo e da base e os dados de temperatura foram submetidos ao teste ANOVA de medidas repetidas e aos testes de Tukey e Dunnet (p=5%). Os resultados revelaram diferença estatística significante de microdureza no topo e na base quando se utilizaram ambos os LEDs por 10 s em relação ao uso do XL 3000 por 40 s, não havendo diferenças estatísticas entre os grupos com os tempos de 20 s e 40 s. A utilização do LED Radii pelos tempos de 10 e 20 s não foi suficiente... / The aim of this study was to evaluate the efficiency of polymerization of a resin composite and the temperature variation in bovine dentine, using two curing units of Light Emitting Diode (LED) of high intensity in comparison to a Quartz-Halogen-Tungsten device (QTH). The light curing units used were: Curing Light XL 3000 (3M, 600 mW/cm2), LED SmartLite PS (Dentsply, 950 mW/cm2) and LED Radii (SDI, 1400 mW/cm2) and the resin composite, Esthet X (Dentsply). For the test of Vickers microhardness, 84 specimens (2 mm X 5 mm) were prepared in bipartite matrix of teflon, varying the time of exposition in 10, 20 and 40 s. The curing unit XL 3000 was used for the control group for 40 s. After 24 h, the microhardness test was made on the top and base of the specimens with 50 g of load and 15 s of duration. For the temperature variation measurement caused by the different curing units, 45 slices of bovine dentine of 0.7 mm thickness and a thermocouple type T hardwired to a system of data acquisition ADS 2000 IP (Lynx Technology) were used. The slices were divided in three groups and the temperature variation was measured in three stages: 1) during the adhesive photopolymerization (10 s); 2) during resin composite photopolymerization (40 s) and 3) after 24 h (40 s). The values of microhardness of the top and the base and the data of temperature variation were submitted to ANOVA of repeated measures test and to the tests of Tukey and Dunnet (p=5%). The results showed statistical significant difference of microhardness for the top and base values when both LEDs were used for 10 s in relation to the use of XL 3000 for 40 s, but no statistical differences were found between the groups when the exposition time was 20 s and 40 s. The use of LED Radii for 10 s and 20 s was not enough to equal statistically ... (Complete abstract, click electronic access below)
408

Análise comparativa da transmitância de diferentes tipos de resina composta pelo método de espectrofotometria de luz visível

Queiroz, Renato Souza [UNESP] 28 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-28Bitstream added on 2014-06-13T19:10:18Z : No. of bitstreams: 1 queiroz_rs_me_arafo.pdf: 1256542 bytes, checksum: fc1faa7ab6e3827911b6c0203d2355cf (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foi avaliada comparativamente, pelo método de espectrofotometria de luz visível, a transmitância de 7 diferentes resinas compostas: G1- Charisma A2; G2-Filtek Supreme A2E; G3- Filtek Supreme A2B; G4- Filtek Supreme YT; G5- Esthet-X A2; G6- Esthet-X YE; G7- Durafill A2, e G8- Z-100 A2. Foram confeccionados 10 corpos de prova para cada grupo experimental com 10 mm de diâmetro e 2 mm de espessura. As amostras foram avaliadas em 3 períodos (inicial, antes da imersão, 24h e 10 dias após imersão em saliva artificial). Os valores obtidos pela transmitância direta, nos comprimentos de onda de 460 a 640 nm, foram submetidos à análise de variância a dois critéiros e teste de Tukey. Os resultados evidenciaram uma homogeneidade de valores entre as amostras e em função do tempo. Pode-se concluir que os valores de transmitância aumentaram significativamente conforme se aumentou os comprimentos de onda de 460 a 640 nm; O comportamento dos grupos experimentais foi similar em função do tempo, sendo que no tempo inicial e após 10 dias os resultados foram semelhantes entre si e estatisticamente superiores aos valores obtidos após 24 horas de imersão; O grupo G4 apresentou sempre a maior média de transmitância ao longo dos comprimentos de onda, em todos os tempos; Os grupos G6 e G7 foram semelhantes entre si com relação à transmitância e superiores aos grupos em ordem crescente de transmitância por G8=G2=G1>(G5=G3). / It was evaluated comparatively with ultra-visible spectrophotometer, the transmittance of 7 different composite resins: G1- Charisma A2; G2-Filtek Supreme A2E; G3- Filtek Supreme A2B; G4- Filtek Supreme YT; G5- Esthet-X A2; G6- Esthet-X YE; G7- Durafill A2, e G8- Z-100 A2.Ten samples (10 mm of diameter and 2 mm of thickness) were made for each experimental group. The samples were evaluated in 3 periods (initial, before the immersion, 24h and 10 days after immersion in artificial saliva). The values of the direct transmittance, in the wave lengths of 460 the 640 nm, were submitted to the two-way analysis of variance and Tukey's intervals. The results had evidenced homogeneity of values between the samples in function and of the time. It can be concluded that the values of transmittance had increased significantly if increased the wave lengths of 460 the 640 nm; The experimental groups reveled similar values in function of the time; the initial time and 10 days after immersion, the results had been similar between itself and superior to the values after 24 hours of immersion; The G4 group always presented the average greater of transmittance to the long one of the wave lengths, in all the times; The groups G6 and G7 had been similar between itself with relation to the transmittance and superiors to the groups orderly increasing of transmittance for G8=G2=G1>(G5=G3).
409

Avaliação da profundidade de polimerização de uma resina composta, pela técnica trans-dental, utilizando-se três diferentes fontes de luz: halógena, laser de argônio e leds

Rastelli, Alessandra Nara de Souza [UNESP] 18 February 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-02-18Bitstream added on 2014-06-13T20:31:08Z : No. of bitstreams: 1 rastelli_ans_me_arafo.pdf: 843933 bytes, checksum: 3b62898b2965cd923e0392e3b0cc6a96 (MD5) / O objetivo desse trabalho foi avaliar a capacidade de polimerização, através da estrutura dental, de três diferentes fontes de luz (Halógena, Laser de Argônio e LEDs), por meio do teste de microdureza. Para isto, foram confeccionados corpos-de-prova em uma matriz metálica circular contendo um orifício na porção central com 4 mm de diâmetro e 2 mm de profundidade. Utilizou-se a resina composta microhibrida Charisma (Heraeus-Kulzer), na cor A2, para a confecção dos corpos-de-prova. Cinco corpos-de-prova foram confeccionados para cada situação diferente, perfazendo um total de 140 corpos-de-prova, distribuídos em 3 grupos da seguinte maneira: GRUPO I - fonte de luz halógena utilizada pelos tempos de exposição de 20 e 40 segundos, para as espessuras de 0 (grupo controle); 1,2 mm; 1,5 mm e 2,0 mm de faceta de estrutura dental; GRUPO II - fonte de luz de laser de argônio utilizada pelos tempos de exposição de 20 e 40 segundos, para as espessuras de 0 (grupo controle); 1,2 mm; 1,5 mm e 2,0 mm de faceta de estrutura dental e GRUPO III - fonte de luz à base de LEDs utilizada pelos tempos de 20, 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,2 mm; 1,5 mm e 2,0 mm de faceta de estrutura dental. Após a confecção dos corpos-de-prova, estes foram armazenados em estufa a 37ºC durante 24 horas. Após o período de armazenamento, procedeu-se o teste de microdureza Vickers, realizando-se 12 impressões para a superfície de topo (voltada à fonte de luz) e 12 para a superfície de base (oposta à fonte de luz). Os dados foram submetidos à Análise Estatística de Variância (P<0,05). Os valores dos desvios padrão das medidas de microdureza foram menores do que 1% da média, indicando diferença estatisticamente significante entre quase todos os grupos. Baseados nos resultados encontrados, pudemos concluir que... . / The objective of this study was evaluate the light-curing capacity, throught dental structure, of three differents light-curing device (Halogen, Argon Laser and LEDs), by microhardness testing. The specimes were made in a circular metallic mold with a of orifice in the cental portion measuring 4 mm in diameter and 2 mm in thickness. The composite resin was used the Charisma (Heraeus-Kulzer) at collor A2. Five samples was made by situation analyzed, adding up one hundred and forty samples: GROUP I - halogen light-curing device by exposure times of 20 and 40 seconds for the thickness 0 (control group); 1,2 mm; 1,5 mm and 2,0 mm of the structure dental facet; GROUP II - argon laser light-curing device by exposure times of 20 and 40 seconds for the thickness 0 (control group); 1,2 mm; 1,5 mm and 2,0 mm of the structure dental facet and GROUP III - LEDs light-curing device by exposure times of 20, 40 and 60 seconds for the thickness 0 (control group); 1,2 mm; 1,5 mm and 2,0 mm of the dental structure facet. After the polymerization procedures the specimes were stored at room temperature of 37ºC for 24 hours. After the storing, the microhardness testing was made, take effecting 12 impressions for the top surface and 12 for the botton surface. The hardness values means obtained were calculed and the statistically analised using Anova (P<0,05). According to the results, it was conclude that: 1) highest the thickness of the dental estructure face, have been a decreasing of the means values of microhardness, independent of the light-cured device utilized; 2) highest exposure times provided higher values means of the microhardness, independent of the light-cured device utilized; 3) the top surface showed the highest means values of hardness, independent of the light-cured device utilized; 4) the halogen light-cured device raised suitable... (Complete abstract, click electronic address below).
410

Estudo da contração de polimerização e do grau de conversão em função de diferentes resinas compostas e diferentes aparelhos fotopolimerizadores

Carlo, Hugo Lemes [UNESP] 19 October 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-10-19Bitstream added on 2014-06-13T18:51:43Z : No. of bitstreams: 1 carlo_hl_me_arafo.pdf: 663650 bytes, checksum: 1703d1cf829a007bfb4eb9e624207ea1 (MD5) / O objetivo deste trabalho foi avaliar a contração de polimerização linear e o grau de conversão de duas marcas comerciais de resinas compostas, com composições semelhantes, sendo uma de uso em dentes anteriores e posteriores (Filtek Z250) e outra para uso em dentes posteriores (Filtek P60). Também foi avaliado o efeito de diferentes fontes de luz nesse processo, utilizando-se para isso aparelho de luz halógena (Degulux - Degussa) e aparelho LED de alta intensidade (Ultrablue IS - DMC). Dessa forma, os materiais e fontes de luz foram divididos em quatro grupos: Grupo 1 - resina Filtek Z250 polimerizada com o aparelho de luz halógena (LH); Grupo 2 - resina Filtek Z250 polimerizada com aparelho LED (LED); Grupo 3 - resina Filtek P60 polimerizada com o aparelho de luz halógena (LH); Grupo 4 - resina Filtek P60 polimerizada com o aparelho LED (LED). A contração de polimerização foi medida com a inserção dos materiais em um anel plástico e a mensuração das alterações realizada por um instrumento eletrônico de medida linear com sensibilidade para 1 æm. O grau de conversão foi obtido através de teste de espectrometria no infravermelho por transformações de Fourier (FTIR), onde foram analisados os picos dentro das bandas de interesse nos valores de 1.646 cm-1 e 1.731 cm-1, correspondentes às ligações C=C alifática e C=O respectivamente. Os resultados foram submetidos à análise estatística de Variância e teste de Tukey (a = 0,05), os quais permitiram concluir que: a contração de polimerização de diferentes materiais (Filtek Z250 e Filtek P60) apresentou comportamento diferente mediante a mesma fonte luz (LED); o grau de conversão dos materiais apresentou-se estatisticamente semelhante em relação aos materiais e aparelhos fotopolimerizadores; o aparelho LED (Ultrablue IS) apresentou resultados de...

Page generated in 0.0205 seconds