• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 1
  • Tagged with
  • 44
  • 44
  • 44
  • 44
  • 44
  • 44
  • 44
  • 40
  • 36
  • 32
  • 16
  • 13
  • 11
  • 10
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avalia??o e compara??o de instrumentos endod?nticos rotat?rios de NiTi antes e ap?s o uso cl?nico

Weis, Adriano 18 January 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:50Z (GMT). No. of bitstreams: 1 428355.pdf: 4558366 bytes, checksum: 162a6f78756da7890951b745bc913a80 (MD5) Previous issue date: 2011-01-18 / O objetivo deste estudo foi avaliar e comparar instrumentos rotat?rios de NiTi antes e ap?s o uso cl?nico. Vinte e quatro conjuntos de instrumentos rotat?rios de NiTi do sistema ProTaper (Dentsply-Maillefer, Ballaigues, Sui?a) foram divididos em dois grupos de forma aleat?ria. Os intrumentos do grupo 1 (n=12) foram armazenados para posterior realiza??o dos testes mec?nicos. Os intrumentos do grupo 2 (n=12) foram encaminhados para um ?nico endodontista, o qual utilizou cada conjunto no preparo de dez canais radiculares. Ap?s coleta dos instrumentos, todas as limas S1, S2 e F1 dos dois grupos, foram testadas quanto a sua resist?ncia a fadiga c?clica. Para este teste foi utilizado um simulador de canal curvo de a?o inoxid?vel com 1,5mm de di?metro interno, ?ngulo de 90 graus e raio de 6mm onde os instrumentos foram introduzidos com velocidade de 350 rota??es por minuto (RPM) at? acorrer a fratura dos mesmos. O tempo transcorrido para que ocorresse a fratura foi analisado e transformado em RPM. O tamanho dos fragmentos tamb?m foi analisado. Os dados foram analisados utilizando o teste de normalidade de Kolmogorov-Smirnov ao n?vel de signific?ncia de 1% e foram analisados com ANOVA de dois fatores (RPM e tamanho do fragmento), seguido do teste de Tukey ao n?vel de signific?ncia de 5%. Os resultados obtidos mostraram diferen?a significativa para o fator RPM (p=0,008), mas n?o significativa para o fator tamanho do fragmento (p=0,12). Valores m?dios de RPM obtidos foram de 641 para o instrumento S1 novo (?127,92); 476 para S1 usado (? 182,92); 545 para S2 novo (?66,61); 504 para S2 usado (?150.01); 453 para F1 novo (?53,18) e 433 para F1 usado (?153,43). Os valores m?dios dos fragmentos (mm) registrados foram de 6,41 8 (S1 nova); 7,46 (S1 usada); 6,95 (S2 nova); 7,35 (S2 usada); 7,30 (F1 nova) e 7,09 (F1 usada). Todos os instrumentos foram analisados em uma vista lateral e na superf?cie de fratura em microscopia eletr?nica de varredura (MEV) para an?lise qualitativa dos instrumentos fraturados
12

Influ?ncia da fadiga c?clica de instrumentos rotat?rios de NiTi em canal curvo simulado

Carvalho, Henrique Parente de 18 January 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:50Z (GMT). No. of bitstreams: 1 428359.pdf: 582244 bytes, checksum: c0e24791c0bf94ca1e52e3ad9c02d954 (MD5) Previous issue date: 2011-01-18 / Os objetivos deste estudo foram avaliar e comparar instrumentos endod?nticos rotat?rios de NiTi de duas marcas comerciais distintas quanto a resist?ncia a fadiga c?clica, microestrutura, morfologia externa, onde vinte limas rotat?rias de n?quel-tit?nio novas, foram levadas ? an?lise. Estas limas foram distribu?das em dois grupos, de acordo com o sistema, sendo o primeiro composto de 10 limas K3 (SDS Kerr, Glendora, CA EUA), e o segundo, por 10 limas Profile (Maillefer, Ballaiques, Sui?a). As dimens?es das limas testadas s?o correspondentes ?s especifica??es 25.06 (di?metro na ponta igual a 0,25mm, e conicidade 0,06). Foram feitas observa??es das limas por microscopia eletr?nica de varredura, com an?lise de EDS, para caracteriza??o das condi??es superficiais do material como fornecido. A superf?cie de corte e a microestrutura tamb?m foram analisadas. Ap?s esta an?lise, as amostras foram submetidas a um ensaio de fadiga por flex?o atrav?s de um sistema composto por um canal artificial met?lico com um ?ngulo de curvatura de 90 graus e um motor el?trico onde o contra-?ngulo foi conectado. O protocolo de velocidade estabelecido foi de 350 RPM. As limas foram inseridas em movimento rotat?rio, at? o momento da fratura. O registro de tempo foi realizado com um cronometro digital at? o momento da fratura. O n?mero de ciclos necess?rios para fratura da lima foi calculado atrav?s da rela??o tempo e rota??es por segundo at? a fratura de cada instrumento. Os vinte fragmentos recuperados foram medidos (mm) atrav?s de um paqu?metro digital. Com base nas observa??es deste estudo, pode-se constatar que as limas apresentam a mesma composi??o superficial e padr?o de microestrutura, entretanto, os instrumentos se diferem quanto ? morfologia externa. Sob a condi??o experimental do estudo atual, o sistema Profile apresentou a resist?ncia ? fadiga c?clica significativamente maior quando comparada ao do sistema K3, testadas em uma curvatura abrupta de 90?. A lima K3 apresentou m?dia de 547 enquanto a Profile apresentou m?dia de 807. Quanto ao tamanho dos fragmentos n?o houve qualquer rela??o entre as diferentes propostas. Pode-se concluir que as limas apresentam a mesma composi??o superficial e padr?o de microestrutura, entretanto se diferem quanto ? morfologia externa
13

Diferentes tipos de substrato dentin?rio podem influenciar a resist?ncia de uni?o em cimento resinoso autoadesivo?

Scheid, Patricia Alves 21 January 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:53Z (GMT). No. of bitstreams: 1 430602.pdf: 3992171 bytes, checksum: dbc119f68b2383c9f1f45cacf8eaf454 (MD5) Previous issue date: 2011-01-21 / Este trabalho se prop?s a avaliar a influ?ncia de diferentes substratos dentin?rios da resist?ncia de uni?o de um cimento resinoso autoadesivo. Foram pr?-selecionados 50 molares humanos, sendo 25 contendo restaura??es de am?lgama e 25 contendo tecido cariado. Os dentes com tecido cariado foram desgastados em politriz com aux?lio de lixa de carbeto de s?licio de granula??o 100 at? a remo??o de tecido cariado, expondo uma dentina afetada por c?rie. Os dentes contendo restaura??es de am?lgama seguiram o mesmo protocolo, at? a remo??o da restaura??o, expondo uma dentina com altera??o de cor. Os dentes que n?o apresentaram dentina afetada por c?rie ou dentina alterada pelo am?lgama circundados por dentina h?gida foram descartados. Foram realizadas tomadas radiogr?ficas a fim de selecionar os dentes que apresentavam dentina remanescente de 2 a 3 mm. Os dentes selecionados tiveram suas ra?zes embutidas em resina acr?lica autopolimeriz?vel. Foram confeccionadas pastilhas de resina composta microh?brida (Sinfony, 3M ESPE) conforme as orienta??es do fabricante. A cimenta??o com o cimento resinoso autoadesivo RelyX Unicem (3M ESPE) foi realizada em dentina ?mida, mantida sob press?o de 0,8 kg e fotopolimerizada com luz hal?gena (3M ESPE) por um per?odo total de 80 segundos. As amostras foram armazenadas por 24 horas em 100% de umidade a 37?C. As restaura??es foram inclu?das com resina acr?lica autopolimeriz?vel e submetidas a cortes seriados, obtendo-se o formato de palitos. Os palitos foram examinados e divididos de acordo com o tipo de substrato dentin?rio que apresentavam: h?gido, cariado e alterado por ?ons provenientes de am?lgama. Os esp?cimes (n=24) foram submetidos ao teste de resist?ncia de uni?o ? microtra??o na m?quina de ensaios universal EMIC DL-2000 com velocidade de 0,5mm/minuto. Os resultados foram submetidos a An?lise de Vari?ncia e ao teste de Tukey HSD. O substrato h?gido apresentou o maior valor m?dio de resist?ncia de uni?o (7,58?2,95 MPa). O substrato alterado por ?ons met?licos apresentou um valor m?dio de resist?ncia de uni?o intermedi?rio (6,43?4,46 MPa) n?o diferindo estatisticamento dos demais grupos avaliados. O substrato afetado por c?rie apresentou o menor valor m?dio de resist?ncia de uni?o (4,21?3,1 MPa) diferindo estatisticamente do substrato h?gido. O tipo de fratura foi analisado atrav?s de imagens obtidas em MEV e a falha do tipo mista foi predominante no substrato afetado por c?rie (85%) e no substrato alterado por ?ons met?licos (100%) enquanto que no substrato h?gido houve predomin?ncia de falha adesiva (54%). Os resultados sugerem que diferentes substratos dentin?rios podem afetar a resist?ncia de uni?o do cimento resinoso RelyX Unicem.
14

Avalia??o da resist?ncia ? uni?o dentin?ria entre tratamento ultra-s?nico e alta rota??o na interface dente/material restaurador

Conde, Alexandre 08 January 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:14Z (GMT). No. of bitstreams: 1 387554.pdf: 6424305 bytes, checksum: eede53bc1323d5be8d0e3d939fde81ca (MD5) Previous issue date: 2007-01-08 / Dezessete terceiros molares h?gidos extra?dos foram utilizados com objetivo de avaliar a dentina quanto: resist?ncia ? uni?o por microtra??o (μTBS) com resina composta (CR) Z250 e adesivo Single Bond 2 (3M); aspecto pr?vio ao tratamento adesivo (APTA); uni?o adesiva (UA); tipo de fratura por microscopia eletr?nica de varredura (MEV) e espectroscopia por dispers?o de energia (EDS) comparando o tratamento com ponta diamantada KGSorensen (PD) e haste ultra-s?nica CVDentUS (UT) com (c/a) ou sem (s/a) condicionamento ?cido. Quatro grupos (n=40) divididos conforme processamento dentin?rio (PDs/a; PDc/a; UTs/a; UTc/a) foram restaurados, inclu?dos em resina acr?lica autopolimeriz?vel e transformados em pequenas barras por m?quina de corte seriado para posterior ensaio de μTBS em m?quina universal EMIC DL-2000 (0,5 mm/min). As amostras foram analisadas por MEV e EDS para classifica??o de fratura, UA e APTA. Os testes estat?sticos foram: Kolmogorov-Smirnov; An?lise de Vari?ncia fatorial; Tukey e Exato de Fisher (p≤0,05). As falhas foram classificadas em: Coesiva em dentina (CD); coesiva em CR (CM); interfacial coesiva na base ou topo de camada h?brida (CBT); interfacial coesiva adesiva (CA); mista (M); interfacial no smear layer (S). Os resultados mostraram (grupo, m?dia μTBS em MPa - desvio padr?o): (UTc/a, 45,31-8,16); (PDc/a, 34,04-9,29); (UTs/a, 15,17-3,71); (PDs/a, 9,86-3,80). O m?todo PD est? associado ? CBT e o m?todo UT ?s CA e CM, c/a est? associado ?s CBT e CM e s/a ? S. O APTA mostrou: PDs/a total obstru??o dos canal?culos dentin?rios (cd); UTs/a parcial desobstru??o dos cd e aspecto irregular de superf?cie; PDc/a completa desobstru??o dos cd; UTc/a completa desobstru??o dos cd e aspecto irregular de superf?cie. Em PDs/a ocorreu camada h?brida retil?nea sem penetra??es de tags (PT); UTs/a, curvil?nea com algumas PT; PDc/a, retil?nea com PT; UTc/a, curvil?nea com PT. Concluiu-se que a associa??o do tratamento UTc/a promove valores maiores de μTBS. Existe associa??o entre falha CBT com o m?todo PD, falhas CA e CM com o m?todo UT, falhas CBT e CM com o m?todo c/a e falha S com o m?todo s/a. As falhas que ofereceram maior resist?ncia para seu rompimento s?o, em ordem decrescente: CD; CM; CBT; CA; M; S
15

Compara??o da distribui??o de tens?es em dois tipos de conex?o prot?tica de implantes com parafusos diferentes utilizando o m?todo de an?lise por elementos finitos com modelo tridimensional

Herbstrith Segundo, Reg?nio Mahfuz 12 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:30:17Z (GMT). No. of bitstreams: 1 388162.pdf: 14806898 bytes, checksum: 307d9a5db880718206e03f9e7a7c7223 (MD5) Previous issue date: 2006-12-12 / O objetivo deste estudo foi avaliar e comparar qualitativamente, atrav?s de an?lise por elementos finitos com modelo 3D, a distribui??o das tens?es geradas por cargas simuladas sob modelos de implantes, pilares, coroas prot?ticas metalocer?micas na regi?o de primeiros molares. As an?lises foram executadas em 4 modelos tridimensionais: modelo 1 e modelo 2 com encaixe prot?tico tipo hex?gono externo e parafuso de pilar de ouro e tit?nio respectivamente, modelo 3 e modelo 4 com encaixe tipo hex?gono interno e parafuso de pilar de ouro e tit?nio respectivamente, a carga aplicada foi padronizada em 382N com duas angula??es diferentes, inclina??es de 90? com a superf?cie oclusal e de 15? em rela??o ao longo eixo dos implantes, em dois pontos distintos, 4 e 6 mm do centro do implante, em 10 pontos diferentes de observa??o no conjunto implante-pilar-parafuso. Os resultados obtidos sugeriram que de uma maneira geral, os modelos com encaixe interno (3 e 4) possuem um melhor comportamento mec?nico em rela??o a distribui??o de tens?es ao longo do complexo implante-pilar-parafuso. Nos modelos 1 e 2 o tipo de material que o parafuso de pilar ? feito influencia na distribui??o de tens?es, por outro lado, nos modelos 3 e 4 isto n?o foi observado
16

Influ?ncia do tempo de armazenamento na rugosidade, tra??o diametral e compress?o de gessos odontol?gicos

Cesero, Leonardo de 15 January 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:18Z (GMT). No. of bitstreams: 1 446374.pdf: 760995 bytes, checksum: fdb1e9bc7072bab1285303e1a7f13c42 (MD5) Previous issue date: 2013-01-15 / The post pouring time to remove dental stone from impression is controversial regardless to strength and roughness. The aim of this study was evaluate the influence of post pouring time in the surface roughness, compressive and diametral tensile strength (DTS) of type IV dental stone. Two hundred and seventy dental stone samples were made from three commercial brands (Durone, Fuji Rock and Tuff Rock). Surface roughness, compressive and diametral tensile strength tests were performed 1 hour, 24 hours and 7 days after pouring. Samples of 6 mm in diameter and 3 mm in height were produced for roughness and DTS tests. Samples of 3 mm in diameter and 6 mm in height were used for compressive strength. Results were submitted to the general linear model and Tukey test (α=0.05). The surface roughness (Ra) registered to different types of dental stone vary from 0.30 μm (Durone 1 hour) to 0.64 μm (Tuff Rock 7 days). The diametral tensile strength (MPa) ranged from 3.94 (Tuff Rock 1 hour) to 9.20 (Durone 7 days). For compressive strength (MPa), data vary from 26.67 MPa (Durone 1 hour) to 65.14 MPa (Fuji Rock 7 days). There was a significant increase of surface roughness (p=0.005), diametral tensile strength (p=0.001) and compressive strength (p=0.001) as time passes after pouring. Commercial brand factor influenced roughness (p=0.001), diametral tensile strength (p=0.004) and compressive strength (p=0.001). Tuff Rock showed the highest surface roughness. The highest DTS was recorded for Durone and Fuji Rock. Fuji Rock showed the highest compressive strength. / O tempo de espera para a remo??o dos modelos de gesso dos moldes em rela??o a sua resist?ncia mec?nica ? controverso. O objetivo desse trabalho foi avaliar a influ?ncia do tempo de armazenamento na rugosidade, tra??o diametral e compress?o de gessos tipo IV. Foram confeccionadas 270 amostras, sendo 90 para cada marca comercial (Durone, Fuji Rock e Tuff Rock). Os testes de rugosidade, tra??o diametral e compress?o para os tempos de armazenagem de 1 hora, 24 horas e 7 dias foram realizados. Para os testes de rugosidade superficial e tra??o diametral amostras de 6 mm de di?metro por 3 mm de altura foram confeccionados. Para o teste de compress?o amostras de 3 mm de di?metro por 6 mm de altura foram utilizadas. Foi utilizado um rugos?metro, para a medi??o da rugosidade m?dia de superf?cie (Ra). Os corpos de prova foram montados na m?quina de ensaio universal e posteriormente realizados os testes de tra??o diametral e compress?o nos respectivos tempos. Os resultados foram submetidos ao modelo linear geral e teste de Tukey (α=0,05). Os valores de rugosidade registrados para os diferentes tipos de gesso variaram de 0,30 μm (Durone 1 hora) ? 0,64 μm (Tuff Rock 7 dias). Os valores de tra??o diametral registrados para os diferentes tipos de gesso variaram de 3,94 MPa (Tuff Rock 1 hora) ? 9,20 MPa (Durone 7 dias). Os valores de compress?o registrados para os diferentes tipos de gesso variaram de 26,67 MPa (Durone 1 hora) ? 65,14 MPa (Fuji Rock 7 dias). Conclu?mos que houve um aumento estatisticamente significante para o fator tempo em rela??o a rugosidade (p=0,005), tra??o diametral (p=0,001) e compress?o (p=0,001). O fator marca comercial influenciou significativamente na rugosidade (p=0,001), tra??o diametral (p=0,004) e compress?o (p=0,001). O gesso Tuff Rock apresentou maior rugosidade, os gessos Durone e Fuji Rock apresentaram o maior valor ? tra??o diametral e o gesso Fuji Rock o maior valor a compress?o.
17

Avalia??o da aplica??o de uma solu??o experimental inibidora de metaloproteinase na resist?ncia de uni?o mediata de sistemas adesivos

Melara, Rafael 21 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:20Z (GMT). No. of bitstreams: 1 447186.pdf: 2766501 bytes, checksum: a394900abd9b1fe55a4a5e1b39342bad (MD5) Previous issue date: 2013-03-21 / This study aimed to evaluate, in vitro, the mediate microtensile bond strength- μTBS (12 months) of adhesive systems Adper Scotchbond SE / 3M/ESPE (Adper SE) and Adper Scotchbond Multi-Purpose / 3M/ESPE (Adper SMP) to sound dentin surface, treated or not with an experimental acid solution inhibitor of metalloproteinases (MMPs), as well as the predominant pattern of failure by fractography; and evaluate, in vitro, the inhibition of gelatinolytic activity by an experimental acid solution for dentin surface etching containing tetracycline compared with an experimental solution containing tetracycline. For mediate μTBS evaluation, in Adper SE Control and Adper SMP Control groups, the adhesive system was applied according to the manufacturer's instructions. In Adper SE Experimental group was applied the experimental solution prior to the adhesive system, and in the Adper Experimental SMP group, the etching with 37% phosphoric acid was replaced by applying the experimental solution. After applying the adhesive systems, the teeth were prepared for μTBS test, and the sticks were stored in an oven at 37?C. After 12 months μTBS test was realized and the sticks were evaluated by SEM. For enzymatic activity evaluation, saliva samples were collected from healthy donors, centrifuged and the supernatant was used by technique of zymography. This technique was based on the use of electrophoresis, in which a protein substrate (gelatin) was co-polymerized with acrylamide. The enzymes were separated under non-reducing conditions, renatured and then incubated in suitable buffer, based on the association between the substrate digestion and verification of the molecular weight of proteases. To quantify the relative inhibition by the two solutions was used the Image J software (NIH, Bethesda, MD, USA) and compared with the control. For mediate μTBS evaluation, according to the Tukey test (α = 0.05), no difference between the control and experimental groups was found for each adhesive system. The predominant pattern of failure for the system Adper SE was cohesive in composite while for Adper SMP was cohesive in hybrid layer. In the enzymatic activity evaluation, the enzymes were characterized as matrix metalloproteinases, because its expression was inhibited by EDTA (a known inhibitor of MMPs), while NEM (an inhibitor of serine proteases) had no effect on enzymatic activity. The MMP identified in the study, was characterized as MMP-2, with a molecular weight of 62KDa. The experimental acid solution presented an inhibition of the gelatinolytic activity of 93.66% (concentration 0.05%) and 58.58% (0.01% concentration), while the experimental solution had a percentage inhibition of 31.28% and 6.83%, respectively. Based on these results we conclude that after 12 months of storage, the adhesive system Adper SE showed better performance that Adper SMP in the microtensile bond strength test, also seeming to be more effective in maintaining the integrity of the adhesive interface, under fractographic analysis; and that the experimental acid solution for dentin surface etching was capable of almost completely inhibits the enzymatic activity of MMP-2 in a dose dependent manner. / Este estudo teve por objetivo avaliar, in vitro, a resist?ncia de uni?o ? microtra??o (RUM) mediata (12 meses) dos sistemas adesivos Adper Scotchbond SE / 3M/ESPE (Adper SE) e Adper Scotchbond Multi-Uso / 3M/ESPE (Adper SMP) ? superf?cie dentin?ria sadia, tratada ou n?o com uma solu??o ?cida experimental inibidora de metaloproteinases (MMPs), bem como o padr?o predominante de falha por fractografia; e avaliar, in vitro, a inibi??o da atividade gelatinol?tica por uma solu??o ?cida experimental para condicionamento de superf?cie dentin?ria contendo tetraciclina em compara??o com uma solu??o experimental contendo tetraciclina. Para avalia??o da RUM mediata, nos grupos Adper SE Controle e Adper SMP Controle, o sistema adesivo foi aplicado de acordo com as instru??es do fabricante. No grupo Adper SE Experimental foi aplicada a solu??o experimental previamente ao sistema adesivo, e no grupo Adper SMP Experimental, o condicionamento com ?cido fosf?rico a 37% foi substitu?do pela aplica??o da solu??o experimental. Ap?s a aplica??o dos sistemas adesivos, os dentes foram preparados para o teste de RUM, e os palitos obtidos foram armazenados em estufa a 37oC. Ap?s 12 meses, foi realizado o teste RUM e os palitos foram avaliados em MEV. Para avalia??o da atividade enzim?tica, amostras salivares foram coletadas de doadores saud?veis, centrifugadas e o sobrenadante foi usado atrav?s da t?cnica zimogr?fica. Esta t?cnica baseou-se no uso da eletroforese, no qual um substrato proteico (gelatina) foi co-polimerizado com acrilamida. As enzimas foram separadas sob condi??es n?o redutoras, renaturadas e ent?o incubadas em tamp?o adequado, baseando-se na associa??o entre digest?o do substrato e verifica??o do peso molecular das proteases. Para quantificar a inibi??o relativa pelas duas solu??es foi usado o programa Image J (NIH, Bethesda, MD, USA) e comparadas com o controle. Em rela??o ? RUM mediata, de acordo com o teste de Tukey (α=0.05), n?o houve diferen?a entre os grupos controle e experimental para cada sistema adesivo. O padr?o predominante de falha para o sistema adesivo Adper SE foi coesiva em resina composta enquanto que para o Adper SMP foi coesiva em camada h?brida. Na an?lise zimogr?fica, as enzimas foram caracterizadas como metaloproteinases da matriz, pois a sua express?o foi inibida pelo EDTA (um conhecido inibidor de MMPs), enquanto o NEM (um inibidor de proteases serinas) n?o teve nenhum efeito sobre a atividade enzim?tica. A MMP identificada no estudo, foi caracterizada como MMP-2, apresentando um peso molecular de 62KDa. A solu??o ?cida experimental apresentou um percentual de inibi??o da atividade gelatinol?tica de 93.66% (concentra??o de 0.05%) e de 58.58% (concentra??o de 0.01%), enquanto que a solu??o experimental teve um percentual de inibi??o de 31.28% e 6.83%, respectivamente. Com base nos resultados encontrados ? poss?vel concluir que ap?s 12 meses de armazenagem, o sistema adesivo Adper SE mostrou desempenho superior ao Adper SMP no teste de RUM, parecendo tamb?m ser mais efetivo na manuten??o da integridade da interface adesiva, sob an?lise fractogr?fica; e que a solu??o ?cida experimental condicionadora de superf?cie dentin?ria foi capaz de inibir quase completamente a atividade enzim?tica da MMP-2, de uma maneira dose dependente.
18

Efeito da vibra??o s?nica e ultrass?nica em um adesivo autocondicionante e de frasco ?nico na resist?ncia de uni?o em dentina

Cavazzola, Fernanda de C?ssia Mortari 11 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:22Z (GMT). No. of bitstreams: 1 447882.pdf: 1769645 bytes, checksum: 707e21b20055331c157549faf714a8c0 (MD5) Previous issue date: 2013-03-11 / Purpose: Investigate the influence of bonding systems application activated through a sonic and ultrasonic vibration and a sonic prototype on micro-tensile bond strength in dentin. Materials and Methods: Twenty-four extracted caries-free intact human molar teeth were embedded in a self-cured acrylic resin. The enamel was removed, using wet 220-, and 600-grit abrasive papers. Each adhesive system (self-etching primer and a single bottle total etch) was applied according to the manufacturer's instructions. Then, the groups were classified according to the type and method of application of bonding systems. After the adhesive technique, resin composite was condensed and light-cured for 20s. Afterwards, all specimens were completely included in a self-cured acrylic resin to stabilize the restorative material and the adhesive interface for the serial sections in a cutting machine. These cylinders were stored in distilled water at room temperature 37?C for 24h. The specimens were stressed in the interface between the composite and the dental surface until fracture occurred. The values were recorded in MPa, and submitted to statistical analysis. Data were submitted to Kolmogorov-Smirnov normality test. Two-way ANOVA and Tukey s Test for pairwise multiple comparisons were used (p<0.05). The failure modes were recorded in percentages.Results: The micro tensile bond strengths with sonic vibration were higher than the other groups, showing statistically significant differences. The sonic, ultrasonic and prototype group had more cohesive failure in resin compared to the control group, which had more cohesive failures of the hybrid layer. Conclusion: The application with a sonic vibration is an effective method for the optimization of bond strength in dentin / Objetivo: Verificar se a aplica??o dos sistemas adesivos, por meio da vibra??o do aparelho s?nico, ultrass?nico e de um prot?tipo s?nico aumenta a resist?ncia de uni?o em dentina. A hip?tese experimental ? que a resist?ncia de uni?o nos sistemas adesivos Adper Single Bond 2 e Clearfill SE Bond ? similar tanto nos grupos controle quanto nos grupos que receberem os diferentes tratamentos. Materiais e M?todo: Foram utilizados 24 terceiros molares h?gidos, onde foi realizada a remo??o do esmalte preparando uma superf?cie dentin?ria lisa. Os dentes foram divididos aleatoriamente em 8 grupos, onde cada sistema adesivo foi aplicado de acordo com as recomenda??es do fabricante (aplica??o din?mica manual) e com a vibra??o de aparelho s?nico , ultrass?nico e por um prot?tipo s?nico. Ap?s a t?cnica adesiva, foi aplicada resina charisma A2. As amostras foram inclu?das em resina acr?lica autopolimeriz?vel, preparando um cilindro para os cortes seriados. Estes foram armazenados em ?gua destilada em uma estufa de cultura a 37?C por 24 horas. Ap?s, confeccionou-se os corpos de prova em forma de barra para o ensaio de resist?ncia de uni?o por microtra??o. Os dados obtidos foram submetidos ao teste Kolmogorov-Smirnov para verifica??o de normalidade.A seguir, foram comparados com ANOVA de duas vias e teste de Tukey (p=0,05). A an?lise da fractografia foi realizada porcentualmente. Resultados: A resist?ncia de uni?o do grupo que recebeu a vibra??o s?nica foi maior, apresentando diferen?as estatisticamente significativas, em ambos os sistemas adesivos, comparada com aplica??o din?mica manual e os grupos que receberam tratamento ultrass?nico e do prot?tipo s?nico. Na an?lise fractografia observa-se que os grupos que receberam tratamento s?nico, ultrass?nico e do prot?tipo tiveram maior falha coesiva em resina em rela??o ao grupo controle, que obteve maiores falhas coesivas de camada h?brida. Conclus?o: A utiliza??o da aplica??o s?nica, ? um m?todo eficaz para a otimiza??o da resist?ncia de uni?o em dentina
19

Degrada??o de condicionadores teciduais em pr?teses totais : estudo in situ

Elsemann, Rog?rio Brasiliense 18 January 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:37Z (GMT). No. of bitstreams: 1 389582.pdf: 4751378 bytes, checksum: 96556d08ded117c5d6139618402559ab (MD5) Previous issue date: 2007-01-18 / Este estudo in situ avaliou a degrada??o de condicionadores de tecido em fun??o do tempo de uso cl?nico, mensurando a dureza Shore A e a quantidade do agente plastificante ftalato. Tr?s materiais condicionadores de tecido foram avaliados: Coe-Comfort, Dura Conditioner e Softone. Os tr?s materiais foram manipulados de acordo com as instru??es dos fabricantes e inseridos em canaletas (5x15x2 mm) preparadas na regi?o palatal da superf?cie interna de pr?teses totais superiores de nove pacientes da Cl?nica de Pr?tese Total da FO-PUCRS selecionados de acordo com os crit?rios de inclus?o e exclus?o, que permaneceram utilizando suas pr?teses durante o per?odo de avalia??o. As an?lises foram realizadas no baseline, no terceiro, s?timo e d?cimo-quarto dias, ap?s a inser??o dos condicionadores em boca. As mensura??es da dureza foram registradas por meio de um aparelho dur?metro Shore A anal?gico e a quantidade de plastificante foi mensurada por espectrofotometria de infravermelho. Foram selecionadas aleatoriamente esp?cimes dos tr?s condicionadores de cada intervalo de tempo para an?lise em microsc?pio eletr?nico de varredura. Os dados foram analisados por ANOVA utilizando o delineamento em medidas repetidas seguida pelo Teste de Compara??es M?ltiplas de Tukey e por regress?o linear simples, ao n?vel de signific?ncia de 5%. Todos os condicionadores de tecido testados apresentaram redu??o da quantidade de plastificante ftalato e aumento da dureza ao longo do tempo do estudo. O comportamento geral de degrada??o dos condicionadores de tecido testados foi similar mas o padr?o de lixivia??o de ftalato e de aumento de dureza foi espec?fico para cada material. As maiores altera??es de concentra??o de ftalato e de dureza Shore A dos condicionadores de tecido estudados ocorreram nos primeiros tr?s dias de uso cl?nico. Entre o baseline e o dia 3 o Coe- Comfort apresentou redu??o de aproximadamente 25% da concentra??o inicial de ftalato, sendo estatisticamente diferente dos demais materiais que apresentaram perda de 50%. N?o houve altera??o significativa da quantidade de ftalato entre os dias 3 e 7. A quantidade de plastificante no material est? inversamente relacionada com a dureza dos condicionadores de tecido
20

Avalia??o in vitro da resist?ncia de uni?o ao cisalhamento na colagem de br?quetes por duas fontes de luz

Mezzomo, Claudia Santos 18 January 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:42Z (GMT). No. of bitstreams: 1 386791.pdf: 7078042 bytes, checksum: 4c1fadb128575046216a3274f924db24 (MD5) Previous issue date: 2007-01-18 / O objetivo do presente estudo foi comparar, in vitro, a resist?ncia de uni?o ao cisalhamento de br?quetes colados quando expostos ? luz LED e ? luz hal?gena (QTH) mediante diferentes tempos de exposi??o. Para isso 126 dentes pr?-molares foram divididos em seis grupos de acordo com a fonte de luz e o tempo de exposi??o utilizado. Para o conjunto LED, foram usados os tempos de 5, 10 e 15s e para o conjunto QTH, 10, 20, e 30s. Os aparelhos fotopolimerizadoes LED (Ortholux LED Curing Light, 3M-Unitek EUA) e QTH (XL 3000, 3M Unitek EUA) tiveram suas intensidades avaliadas inicialmente e, a cada 10 colagens, por radi?metros espec?ficos para cada natureza de luz, obtendo valores m?dios de 581mW/cm? e 420mW/cm?, respectivamente. Ap?s 24h de estocagem em ?gua destilada a 37?C, os corpos - de - prova foram levados ? m?quina de ensaio mec?nico (Emic DL 2000?) e submetidos ? tens?o de cisalhamento, no sentido c?rvico-oclusal, ? velocidade de 1mm/min. De acordo com os testes estat?sticos ANOVA e Tukey, houve diferen?a significativa entre os grupos estudados (p< 0,01). Os grupos fotoativados por LED 5s (17,20MPa) e 10s (20,54MPa) n?o diferiram entre si, mostrando diferen?a estatisticamente significativa quando comparados ao grupo LED 15s (25,24MPa). Quanto ? fonte luminosa QTH, o grupo de 10s (16,97MPa) diferiu dos 20s (23,61MPa) e 30s (21,33MPa), enquanto esses n?o diferiram entre 8 si. A maior m?dia de resist?ncia de uni?o foi observada no grupo LED 15s, embora este grupo n?o tenha se diferenciado estatisticamente dos grupos QTH 20s e 30s. Verificou-se que at? mesmo os grupos que tiveram as menores m?dias de resist?ncia de uni?o, QTH 10s e LED 5s, respectivamente, apresentaram valores compat?veis com o uso cl?nico. Segundo o teste Kruskal-Wallis, houve diferen?a significativa na distribui??o dos resultados do IAR entre os grupos (p< 0,01). O grupo LED 15s demonstrou padr?o de fratura predominantemente ?ndice 0, sendo observado fratura de esmalte em dois corpos - de - prova. Apesar dos grupos LED 5s e QTH 10s apresentarem maior predom?nio de escores 1 e 2, respectivamente, foram nesses que se observou a maior freq??ncia de escores 3, QTH 10s (10,5%) e LED 5s (9,5%). Comportamento oposto foi observado nos grupos LED 10s e 15s, onde n?o foi registrado freq??ncia de ?ndice 3 (0%). Os achados do presente estudo sugerem que a tecnologia LED (Free Light Ortholux, 3M Unitek) pode ser utilizada, na colagem de br?quetes, com tempos de cura menores em rela??o ? luz hal?gena para a resina Transbond XT, sendo que, o tempo m?nimo de 5s com LED apresentou valor de resist?ncia de uni?o clinicamente aceit?vel.

Page generated in 0.0303 seconds