• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 85
  • 1
  • Tagged with
  • 86
  • 86
  • 76
  • 66
  • 21
  • 18
  • 18
  • 14
  • 13
  • 13
  • 10
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação comparativa da resistência à abrasão de resinas compostas "condensáveis", submetidas à escovação simulada, através da alteração de massa e da rugosidade superficial. / "In vitro" ëvaluation of abrasion resistance of "condensable" composite resins after toothbrushing. Wear and superficial roughness analysis.

Wang, Linda 02 March 2001 (has links)
Resinas compostas "condensáveis" correspondem a uma nova categoria de material restaurador posterior especialmente desenvolvida como alternativa estética ao amálgama. O objetivo deste trabalho foi comparar algumas marcas comerciais Solitaire (So), SureFil (Su), Alert (A), Prodigy Condensable (PC) e Filtek P-60 (P-60) a dois grupos controles, Silux Plus (SP), de micropartículas, e Z100 (Z), microhíbrida, por meio de um teste in vitro de escovação simulada. Doze corpos-de-prova de cada material foram confeccionados com dimensões de 5mm de diâmetro por 3mm de espessura. Foram realizados 100.000 ciclos de escovação em uma máquina de escovação simulada, utilizando escovas dentais de cerdas macias e solução de dentifrício e água deionizada. A alteração de massa foi verificada pela diferença entre as médias de massa inicial (antes da escovação) e final (depois da escovação) em balança analítica Sartorius. A análise da rugosidade superficial em Ra foi determinada pela diferença entre as médias de cinco leituras, iniciais e finais, com um rugosímetro Hommel Tester T1000 e por meio de microscopia eletrônica de varredura. Os resultados obtidos foram submetidos à análise de ANOVA e Tukey, apresentando diferenças significantes para perda de massa e alteração de rugosidade. As resinas SureFil e Alert apresentaram menor alteração de massa (0,38% e 0,52%), enquanto Solitaire, Prodigy Condensable e Silux Plus as maiores (1,51%, 1,55%, 1,70%). Z100 e P-60 apresentaram alteração de massa intermediária às outras resinas. Diferentemente dos outros grupos, Prodigy Condensable, Solitaire e Z100 apresentaram, após a escovação, superfícies mais lisas (-0,012mm, -0,047mm e -0,065mm respectivamente), enquanto a rugosidade superficial aumentou nos demais grupos (A= 0,073mm, P-60= 0,095mm, Si= 0,158mm e Su= 0,470mm). SureFil apresentou a menor perda de massa e a maior variação de rugosidade superficial comparada às demais resinas testadas. Não houve correlação entre perda de massa e rugosidade superficial. As análises realizadas em microscopia eletrônica de varredura apresentaram-se coerentes com os resultados quantitativos obtidos. De maneira geral, as resinas compostas "condensáveis" apresentaram comportamento semelhante entre si e em relação à resina microhíbrida Z100. / "Condensable" composites resins are a category of posterior materials especially developed as an aesthetic alternative to amalgam. The aim of this research was to compare these materials by an "in vitro" abrasion test simulating toothbrushing. Solitaire (So), SureFil (Su), Alert (A), Prodigy Condensable (PC) and Filtek P-60 (P-60) were compared to two control groups, microfilleD Silux Plus (SP) and microhybrid Z100 (Z). Twelve samples of each material were prepared with 5mm in diameter and 3mm thick. The abrasion test was applied up to 100.000 cicles by an appropriate machine with soft bristles tips containing dentifrice solution and deionized water. The weight loss was detected by the differences between the initial (before toothbrushing) and the final weight (after toothbrushing) using a Sartorius analytical scale. The evaluation of surface roughness was observed by the difference between initial and final means after 5 readings in a Hommel Tester T1000 testing machine. The specimens were also analysed by SEM. The obtained results (ANOVA and Tukey) showed significant differences of weight and surface roughness between the tested materials. SureFil and Alert exhibited lower loss of weight (Su-0.38%; A-0.52%), Solitaire, Prodigy Condensable, and Silux Plus presented greatest wear(So-1.51%; PC-1.55%, SP-1.70%) while Z100 and Filtek P-60 showed intermediate loss ( Z-1.16%; P-60-1.31%). Differently to the others groups, Prodigy Condensable, Solitaire and Z-100 showed a decrease in surface roughness compared to the initial condition (-0.012mm,-0.047mm and -0.065mm respectively) which increased in the remainder groups (A) 0.073mm, P-60) 0.095mm, Si) 0.158mm and Su) 0.470mm). SureFil presented the lowest weight loss and the highest surface roughness variation comparing to the other tested resins. There was no correlation between wear and surface roughness. The SEM results were in accordance to those obtained by the Hommel Tester T1000 testing machine. "condensable" composites resins showed the same behavior compared to the microhybrid Z100 control resin.
22

Avaliação de agentes remineralizadores e dessensibilizantes no tratamento de clareamento dental: estudo in vitro / Evaluating remineralizing and desensitizing agents in dental bleaching treatment: in vitro study

Pintado Palomino, Karen 15 August 2013 (has links)
O objetivo deste estudo foi avaliar comparativamente, in vitro, o efeito de agentes remineralizadores e dessensibilizantes na rugosidade superficial e microdureza do esmalte e dentina bovina exposta a peróxido de carbamida a 16% (T1) ou peróxido de hidrogênio a 35% (T2). Os agentes clareadores T1 e T2 conjuntamente com os agentes remineralizadores/ dessensibilizantes - dentifrício Sensodyne® (D1); dentifrício experimental com 7,5% de micro-partículas de Biosilicato® (D2); dentifrício Odontis RX® (D3); dentifrício Sorriso® (D4); pasta experimental com micropartículas de Biosilicato® (D5); Desensebilize Nano P® (D6); pasta experimental com micropartículas de Bioglass® tipo 45S5 (D7); água destilada (GC) - foram usados considerando os grupos experimentais: T1/D1; T1/D2; T1/D3; T1/D4; T1/D5; T1/D6; T1/D7; T1/GC e T2/D1; T2/D2; T2/D3; T2/D4; T2/D5; T2/D6; T2/D7; T2/GC. Análise de rugosidade superficial (Ra), microdureza e imagens em microscopia eletrônica de varredura (MEV) foram realizadas antes (t0) e após (t1) o tratamento com os géis clareadores (T1= 14 dias/ 4h por dia; T2= sessão única) e os produtos remineralizadores/dessensibilizantes. Os dados colhidos foram analisados intra e intergrupos, estatisticamente por meio de Análise de Variância e Teste de Tukey. Os resultados mostraram que na rugosidade superficial não houve diferença significante (p>0.05) entre a rugosidade inicial (t0) e final (t1) tanto no esmalte quanto na dentina. A microdureza diminuiu nas amostras de dentina para o grupo T1/D6 (t0=40,99/ t1=29,11) e foi aumentada nas amostras de esmalte do grupo T1/D1 (t0=255,0/ t1=318,1). Conclui-se que o tratamento com peróxido de carbamida a 16% ou peróxido de hidrogênio a 35% associado aos agentes dessensibilizante/remineralizantes avaliados neste estudo não alteraram a rugosidade superficial do esmalte e dentina bovina, no entanto a microdureza pode ser alterada quando o peróxido de carbamida a 16% é usado. / This study aimed to evaluate in vitro the effect of remineralizing and desensitizing agents on microhardness (MH) and roughness (RG) enamel and dentin bovine samples exposed to 16% carbamide peroxide (T1) or 35% hydrogen peroxide (T2). Dental bleaching agents - T1 and T2 - together with desensitizing/ remineralizing agents - Sensodyne® dentifrice (D1); experimental dentifrice containing 7,5% micron-sized particles of Biosilicate® (D2); Odontis RX® dentifrice (D3); Sorriso® dentifrice (D4); microsized particles of Biosilicate® paste (D5); Dessensebilize Nano P® (D6); Bioglass® type 45S5 paste (D7); distilled water (CG) were used according to the experimental groups: T1/D1; T1/D2; T1/D3; T1/D4; T1/D5; T1/D6; T1/D7; T1/GC and T2/D1; T2/D2; T2/D3; T2/D4; T2/D5; T2/D6; T2/D7; T2/CG. MH, RG measurements, and images using scanning electron microscopy (SEM) were made on the samples before (t0) and after (t1) the treatment with the bleaching gels (T1= 14 days/ 04 hours/day; T2=single session) and the desensitizing/remineralizing agents. Data was analyzed statistically with One way-ANOVA and posterior Tukey Test. RG evaluation revealed no significant difference (p>0.05) between baseline (t0) and final (t1) RG for all experimental groups. MH decreased in dentine samples for T1/D6 (t0=40,99/ t1=29,11) and increased in enamel samples for T1/D1 (t0=255,0/ t1=318,1). It was concluded that the treatment with carbamide peroxide at 16% or hydrogen peroxide at 35% in combination with desensitizing/ remineralizing agents didnt alter enamel and dentin surface roughness; however microhardness could be affected when peroxide carbamide at 16 % is used.
23

"Análise 'in vitro'da rugosidade superficial apresentada pelas porcelanas omega 900 e vitadur alpha após a utilização de três diferentes sistemas de polimento" / Omega 900 e vitadur alpha ceramics using three different polishing systems

Araujo, Jesuina Lamartine Nogueira 25 June 2003 (has links)
RESUMO A qualidade da superfície de trabalhos cerâmicos que requer ajuste durante a sua adaptação ao remanescente dentário desperta a atenção durante os procedimentos odontológicos restauradores estéticos. Observa-se a necessidade freqüente de realizar desgastes superficiais nas restaurações cerâmicas, sendo que a preservação de uma superfície lisa é importante para as propriedades destes materiais, bem como para o seu comportamento clínico. Este trabalho propõe-se a avaliar a técnica com maior capacidade de polimento da superfície cerâmica asperizada, através da medição com ponta apalpadora de um rugosímetro, e utilizando o MEV para observações visuais com relação às técnicas empregadas. Para tal 80 corpos-de-prova foram confeccionados utilizando-se as porcelanas Omega 900 e Vitadur Alpha, constituindo quatro grupos experimentais: A – glaze (controle); B – polimento com borrachas abrasivas da DFL mais pasta para polimento da KOTA; C – polimento com borrachas abrasivas mais rodas de feltro mais pasta para polimento Porcelize (Cosmedent); D – polimento com borrachas abrasivas mais pasta porcelize mais discos Flexibuff mais pasta diamantada para brilho Enamelize (Cosmedent). Os dados receberam tratamento estatístico por meio da Análise de variância (ANOVA) e teste de Tukey, o qual indicou haver diferença estatisticamente significante entre os tipos de polimento para os quais as porcelanas foram submetidas, e na interação porcelana / polimento. Os resultados sugerem que todos os tratamentos polidores diminuem a rugosidade superficial das porcelanas em relação ao grupo controle e que dependendo da porcelana utilizada para cada técnica pode-se ter uma variação na rugosidade superficial. Quanto à observação pelo microscópio eletrônico de varredura houve uma correlação parcial entre este e os resultados obtidos pelo rugosímetro, pois aqui a porcelana Omega 900 mostrou-se mais polida no grupo controle, enquanto que na análise pelo rugosímetro apontou para a técnica polidora do Grupo D como sendo aquela que produziu uma superfície mais lisa para esta porcelana. Por outro lado, mostrou que o melhor polimento alcançado pela porcelana Vitadur Alpha foi através do polimento do Grupo C, o que está de acordo com os resultados obtidos pelo rugosímetro. / SUMMARY Aesthetic dentistry uses materials that can copy some lost caractheristics of the natural dentition, as color, mechanical resistance and smoothness.The better material for this are the ceramics. On the other hand, it is commum to have to grind them with diamond instruments for adjustment wich removes the glazed surfaces. This procedure can cause abrasion of the opposite teeth, plaque retention, injury of surrounding tissues and low aesthetics qualities. This study evaluated the roughness average in two dental ceramics, Omega 900 e Vitadur Alpha, that were grinding with diamond instruments after the glaze technique, and received three different polishing systems. The control group remained glazed until the end of the research. The groups were: Group A – control; Group B – grinding by fine and ultrafine points + polishing with DFL rubber points + KOTA diamond paste; Group C –grinding by fine and ultrafine points + polishing with rubber points + felt discs + Porcelize diamond paste (Cosmedent); Group D - grinding by fine and ultrafine points + polishing with rubber points + Porcelize + Flexibuff discs + Enamelize polishing paste (Cosmedent). To measure the roughness average in the samples it was used a profilometer Surftest SV-600 with the software Surfpack and the images were observed in the scanning electron microscopy (SEM) to comparation. The results received estatistical analysis using ANOVA and Tukey test (p˜0.05), and a significant tatistical difference was observed between the polishing systems , and in the porcelain/polishing interaction, which showed that all the polishing systems decreased the surface roughness of the porcelains after been grinding with diamond instruments, which was a better result than the control group. In the SEM analysis it was clear the presence of a partial relationship between the profilometer and that one, because here the Omega porcelain showed a more smoothness surface with the glazed treatment compaired with the others, differently from the profilometer analysis
24

Efeitos topográficos em espectros RBS / Topographic effects in RBS spectra

Silva, Alessandro Alves da 24 November 2006 (has links)
A medida da rugosidade de uma superfície costuma produzir resultados que dependem da metodologia empregada. A microscopia eletrônica de varredura, SEM, a microscopia de força atômica, AFM e a perfilometria são algumas das técnicas costumeiramente empregadas na caracterização de superfícies rugosas. Esse trabalho explora a e desenvolve o uso da espectrometria de retroespalhamento Rutherford, RBS, para medir e quantificar a rugosidade de uma superfície. Quatro diferentes amostras com rugosidade periódica e controlada (duas retangulares e duas senoidais) com razão de aspecto suficientemente grande que produzam efeitos mensuráveis por RBS, foram produzidas por interferometria óptica. Os espectros RBS experimentais foram convertidos em rugosidade rms e comparados com resultados de SEM e AFM. Medir rugosidade através de RBS permite inspecionar uma área (da ordem de alguns mm2) e profundidades muito maiores que as acessíveis por AFM, apesar de ainda limitados pela resolução em energia intrínseca da metodologia RBS. / Measuring the roughness of a surface use to produce results which depend on the employed methodology. Scanning Electronic Microscopy, Atomic Force Microscopy, profilometry, are some of the techniques used to characterize surface roughness. This work explores and develops the use of Rutherford Backscattering Spectrometry to measure and quantify the roughness of a surface. Four different samples with controlled and periodic surface profiles (two rectangular waved, and two sinusoidal), with enough aspect ratio to, give measurable effects in an RBS analysis, were produced by optical interferometry to test and verify the proposed methodology. The experimental RBS spectra were converted into rms roughness and compared to SEM and AFM measurements. Measuring roughness by RBS enables one to inspect a much bigger area (of the order of some mm2) and with more depth resolution, than by using an AFM, yet still limited by the experimental intrinsic energy resolution of the RBS methodology.
25

Ação do enxaguatório bucal à base de Casearia sylvestris e Clorexidina 0,12% na cor e rugosidade superficial do esmalte dental submetido ao clareamento caseiro e bebida alimentícia ácida / Action of Chlorhexidine and a mouthwash containing Casearia sylvestris in color and surface roughness of the dental enamel submitted to home bleaching and acid drink

Bohner, Lauren Oliveira Lima 06 December 2013 (has links)
Enxaguatórios bucais podem ocasionar a alteração de cor do elemento dental, devido à desmineralização ocasionada pelo uso prolongado dos mesmos, e consequente aumento da rugosidade superficial. Outros fatores, como o clareamento caseiro e o consumo diário de bebidas ácidas são, da mesma forma, responsáveis pela dissolução do esmalte dental. Buscando superar os efeitos adversos da Clorexidina 0,12%, desenvolveu-se um enxaguatório bucal à base de uma planta medicinal, denominada Casearia sylvestris. O presente estudo teve como objetivo avaliar a ação dos enxaguatórios bucais à base de Casearia sylvestris e Clorexidina 0,12% na cor e rugosidade superfícial do esmalte dental submetido a agente clareador e bebida alimentícia de pH 2,4. Amostras de dentes bovinos foram divididas em 3 grupos (n= 30), de acordo com a solução utilizada: Água destilada, Clorexidina 0,12% e Enxaguatório bucal à base de Casearia sylvestris. Cada grupo foi ainda dividido em subgrupos, de acordo com as categorias (n=10): Grupo controle, dentes clareados e dentes submetidos à imersão em bebida alimentícia ácida. O clareamento caseiro foi realizado com peróxido de carbamida 16%, por 6 horas diárias durante 8 dias, enquanto a imersão em suco de limão (pH 2,4) foi realizada por 2 minutos cada, 1 vez ao dia, durante 6 dias. Posteriormente, os grupos tiveram seus corpos de prova imersos nas respectivas soluções por 2 minutos, 3 vezes ao dia, durante 7 dias. As leituras de cor e rugosidade superficial foram realizadas anteriormente ao período experimental e após a imersão nos enxaguatórios bucais. A análise dos resultados foi realizada através dos testes estatísticos ANOVA - II way e Teste de Tukey 5%. Os dentes submetidos ao clareamento caseiro e à imersão em bebida ácida apresentaram uma maior alteração de cor. As diferentes soluções não apresentaram diferença estatística quanto à alteração de cor. A rugosidade superficial foi maior para o período de 7 dias, sendo que apenas o grupo submetido à imersão em bebida ácida apresentou um aumento significante na rugosidade superficial. Foi possível concluir que apenas o clareamento caseiro e a imersão em bebidas ácidas promoveram alteração na coloração da estrutura dental. Não houve influência dos enxaguatórios bucais utilizados isoladamente ou em associação com os tratamentos na rugosidade superficial. Apenas a imersão em bebida ácida ocasionou aumento na rugosidade superficial. / Mouthwashes can induce the tooth color alteration, due to the desmineralization occured by the prolonged use of them and consequent increase of surface roughness. Another factors, as the home bleaching and the daily consumption of acid drinks are, in the same way, responsible for the dental enamel dissolution. Attempting to overcome the Chlorhexidine 0,12% adverse effects, it was developed a mouthwash containing a medical plant, denominated as Casearia sylvestris. The aim of this study was to evaluate the action of a mouthwash containing Casearia sylvestris and Chlorhexidine 0,12% on color and surface roughness from the dental enamel submitted to bleaching gel and a drink with pH 2,4. Bovine teeth samples were divided in 3 groups (n=30), according to the solution: distillated water, Chlorhexidine 0,12% and a mouthwash containing Casearia sylvestris. Each group was divided in subgroups, according to the categories (n=10): Control group, bleached teeth and teeth immersed in an acid drink. The bleaching procedure was realized with carbamide peroxide 16%, during 6 hours by 8 days, while the acid drink immersion was done during 2 minutes each, once in a day and during 6 days. Posteriorly, the samples were immersed on the respective solutions by 2 minutes, three times at a day, during 7 days. The color and surface roughness lecture were performed before the experimental period and after the immersion on mouthwashes. The data were analyzed by two-way analysis of variance (ANOVA) and Tukey`s test. The teeth submitted to home bleaching and to the immersion in acid drink showed higher color alteration. At the group wich no treatment was applied, the mouthwash containing Casearia sylvestris induce the highest color alteration when compared with the other solutions, and that was statistically equal when the teeth were submitted to different treatments. The surface roughness was higher to the 7 days period, although the only the group submitted to the immersion in acid drink presented a significant enhance on surface roughness. In conclusion, only the bleaching and the immersion in acid drinks promoted a higher color alteration. The mouthwashes did not promoted an alteration on the color of the dental structure. There was no influence from mouthwashes utilized when isolated or in association with the treatments on surface roughness. Only the immersion in acid drink caused an increase on surface roughness.
26

Desenvolvimento da microscopia holográfica digital por reflexão para avaliação 3D de superfícies. / Development of digital holographic microscopy by reflection for 3D surface evaluation.

Valin Fernández, Meylí 08 December 2017 (has links)
Dentre dos procedimentos geradores de perfil óptico encontra-se a microscopia holográfica digital. Esta ferramenta interferométrica surgiu da ideia inicial proposta por D. Gabor sobre holografia, a qual permite mediante o registro da interferência de campos ópticos coerentes, guardar e extrair informações de imagens. A microscopia holográfica digital permite a análise de objetos com resoluções transversais semelhantes às obtidas por microscopia óptica, e ainda, possui a vantagem pela natureza da holografia de permitir realizar análises através do acesso a valores quantitativos de fase. Apresentam-se neste trabalho os conceitos básicos da holografia digital e da microscopia holográfica digital, com o objetivo, de introduzir o desenvolvimento de uma metodologia para a implementação da microscopia holográfica digital por reflexão para o controle dimensional de objetos e determinação da rugosidade superficial de amostras de aço. Os hologramas são obtidos mediante uma instalação óptica, que consiste em um interferômetro de Michelson por reflexão com o uso de uma lente objetiva de microscópio e uma câmera CCD sem lente. Para a reconstrução das imagens de contraste de fase são utilizadas técnicas numéricas que capacitam à microscopia holográfica digital para a supressão do termo de ordem zero, controle da resolução de pixel, desmodulação da fase óptica, determinação dos mapas de intensidades e fase, filtragem e compensação de aberrações dos hologramas obtidos. As reconstruções numéricas dos feixes objeto e referência são realizadas utilizando o método de dupla propagação. Foi desenvolvido um algoritmo que apresenta a imagem de contraste de fase com base num critério de distância a partir de um único holograma. Desta forma o programa utilizado permite a realização de medições quantitativas das dimensões dos objetos e da rugosidade superficial de amostras de aço, assim como, a representação em 3D da imagem de fase reconstruída com resultados validados através de um perfilômetro óptico 3D sem contacto modelo CCI-MP. / Among the procedures generating optical profile is the digital holographic microscopy. This interferometric tool arose from the initial idea proposed by D. Gabor on holography, which allows by recording the interference of coherent optical fields, save and extract information from images. Digital holographic microscopy allows the analysis of objects with transversal resolutions similar to those obtained by optical microscopy, and also has the advantage of the nature of holography to allow to perform analyzes through the access to quantitative phase values. This paper presents the basic concepts of digital holography and digital holographic microscopy, with the objective of introducing the development of a methodology for the implementation of digital holographic microscopy by reflection for the dimensional control of objects and determination of surface roughness of samples of steel. The holograms are obtained by means of an optical installation consisting of a Michelson interferometer by reflection using an objective microscope lens and a lensless CCD camera. For the reconstruction of phase contrast images, numerical techniques are used that enable digital holographic microscopy to suppress the zero-order term, control pixel resolution, optical phase demodulation, determination of intensity and phase maps, filtering and compensation of aberrations of the obtained holograms. Numerical reconstructions of the object and reference beams are performed using the double propagation method. An algorithm has been developed that presents the phase contrast image based on a distance criterion from a single hologram. In this way the program used allows the realization of quantitative measurements of the object dimensions and the surface roughness of steel samples, as well as the 3D representation of the reconstructed phase image with results validated through a 3D contactless optical profilometer model CCI- MP.
27

Metodologia para avaliação da capabilidade de controle de superfícies técnicas usinadas em torno de ultraprecisão / Methodology to assess the capability of the control technical surfaces in ultraprecision turning manufacturing

Camargo, Rosana 21 November 2005 (has links)
A nanotecnologia não é mais um sonho, já faz parte da nossa realidade, do nosso dia a dia. É considerada, por muitos, a quinta Revolução Industrial, uma revolução tecnológica de grande abrangência, que poderá causar impactos talvez sem precedentes na história. A soma anual dos investimentos nesta nova tecnologia é de bilhões de dólares. Devido às inovações oriundas da nanotecnologia, os processos da manufatura e a medição de ultra-precisão vêm se desenvolvendo a cada dia. A nanotecnologia fez da usinagem de ultraprecisão com ferramenta de diamante uma grande aplicação na produção de itens de alto volume, tais como: disco de memória de computadores, lentes de contato, moldes de dentes, cilindros para impressão, espelhos metálicos. A alta integridade da superfície é requerida em todos os itens obtidos por este processo. Em conseqüência, é necessário um método de medição que seja o mais exato possível, isto é, que chegue a resultados o mais próximo possível do valor verdadeiro. Mas o que significa exatidão para uma análise ideal da superfície, uma vez que não existe referência para isso? Superfícies têm sido avaliadas por meio da medição da rugosidade, a qual consiste na determinação de um valor médio, de vários setores, dentro de valores limites preestabelecidos. A metrologia, através de seus métodos e princípios, é um importante instrumento para validar modelos e teorias. O conceito que \"uma vez testado, passa a ser aceito em qualquer lugar\". Daí a crescente necessidade de resultados de medições confiáveis que possam ser validados em qualquer lugar e a qualquer tempo. Assim, um caminho a ser seguido é o de se entenderem profundamente todos os métodos e princípios envolvidos nas operações de medição de rugosidade. E para que um método seja metrologicamente válido (ou aceitável), faz-se necessário realizarem-se comparações de diversas medições, de um mesmo mensurando, utilizando métodos diversos. Havendo discrepância nos resultados, é uma evidência de que as premissas e hipóteses levaram a acreditar que a teoria ou modelo adotado deve ser reavaliado. Este trabalho selecionou os três métodos mais utilizados na caracterização da integridade de superfícies técnicas obtida em torneamento de ultraprecisão com diamante, e descreveu uma metodologia para a avaliação da capabilidade do processo de controle de superfícies técnicas usinadas em torno de ultraprecisão. / Nanotechnology is no longer a dream. It is part of the real world. It is considered by many people as the fifth Industrial Revolution, a technological revolution of great impact in history. The world annual investment in this technology reaches billions of dollars. Due to innovations related to nanotechnology, ultraprecision manufacturing processes and metrology is developing steeply. Nanotechnology made single point diamond turning an important mass production process of, for instance, computer hard discs, contact lenses, moulds, printer cylinders, metallic mirrors, etc. High grade surface integrity is required of items produced by this process. As a consequence, it is necessary to use a measurement method which is most accurate as possible, i.e., resulting in a value as close as possible to the true. But what does true mean if there is no reference for that? Surfaces have been assessed by roughness measurements which determines a mean value of several sectors within pre-determined limits. Metrology, with its methods and principles, is an important instrument to validate models and theories. The concept, once tested, becomes accepted everywhere. Therefore the increasing necessity of reliable measurement results which may be validated anywhere and any time. Thus, it is essential a deep understanding of all methods and principles involved in roughness metrology operations. For a method to be metrologically accepted, it is necessary that it is compared with different methods. In the event of existing discrepancies, the premisses and hypotheses which fundamented the theory or model should be reassessed. Three of the most used methods have been selected to characterize the surface integrity of technical surfaces generated by diamond turning. A methodology to assess the capability of the process of control of those surfaces is proposed.
28

Tratamento superficial dos agregados reciclados de RCD com hidrofugantes. / Surface treatment of CDW recycled aggregates with water-repellents.

Santos, Winnie Franco 04 April 2016 (has links)
A proposta busca reduzir a absorção de água dos agregados reciclados de Resíduos de Construção e Demolição (RCD), através do tratamento de sua superfície com hidrofugante, de maneira que estes não aumentem o consumo de água tampouco reduzam a resistência mecânica. Os agregados reciclados de RCD foram caracterizados quanto à granulometria, morfologia, porosidade, ângulo de contato aparente, absorção de água, análise de imagem e rugosidade superficial. Em seguida, os mesmos foram tratados superficialmente com dois tipos de hidrofugante: solução de silano e parafina. Todos os tratamentos permitiram reduzir a absorção de água dos agregados reciclados de RCD. O tratamento por imersão foi aquele que permitiu obter os melhores resultados e a menor variabilidade entre as técnicas. Os tratamentos hidrofugam a superfície, apesar da parafina apresentar maior molhabilidade. O tratamento com parafina apresentou, em termos de absorção de água, resultados inferiores e menos variáveis que o silano. Os parâmetros de rugosidade constataram que, ambos os materiais perdem seu perfil topográfico original quando tratados com parafina. Os diferentes agregados reciclados com cada hidrofugante foram aplicados em materiais cimentícios analisados no estado fresco e no estado endurecido. Os tratamentos reduziram a absorção e o consumo de água de mistura, porém afetaram negativamente as propriedades mecânicas, devido nova interface gerada (no caso específica de parafina) e falta de molhabilidade nas superfícies. / The proposal aims to reduce the water absorption of the Construction and Demolition Waste (CDW) recycled aggregates through hydrophobic surface treatment, so that these do not increase the concretes water consumption (nor reduce de mechanical strength). The CDW recycled aggregates were characterized regarding granulometry, morphology, porosity, apparent contact angle, water absorption, image analysis and surface roughness. Then they had their surface treated with two types of water-repellent: silane solution and paraffin. All treatments have reduced water absorption of the CDW recycled aggregate. Immersion treatment was the one that allowed the best results and the lowest variability between techniques. The treatments repel water on surface, despite the paraffin presenting better wettability. Paraffin treatment showed, in terms of water absorption, lower and less variable results than silane did. Roughness parameters found that both materials lose their topographic profile when treating with paraffin. The different recycled aggregates with each repellent were applied in cementitious materials analyzed in fresh and hardened state. The treatments reduced absorption and mixing consumption of water in the mixing, but adversely affect mechanical properties due to the new interface created (paraffin wax in special) and the lack of wettability on surfaces.
29

Avaliação in vitro da rugosidade superficial de resinas compostas, comparando diferentes sistemas de acabamento e polimento e após a profilaxia com jato de bicarbonato / In vitro evaluation of surface roughness of different composite resins, comparing different finishing and polishing systems and after prophylaxis with bicarbonate jet

Alves, Carol Brandt 04 October 2012 (has links)
A presente pesquisa in vitro teve como objetivo avaliar a ocorrência de alterações superficiais em três resinas compostas disponíveis comercialmente quando submetidas a tratamentos de polimento e jato de bicarbonato. As alterações foram quantificadas através de análises rugosimétricas e qualificadas através de microscopia eletrônica de varredura. Foram testadas três resinas compostas:nanoparticulada Z350 (3M ESPE, Saint Paul- MN, EUA), microhíbrida Z250 (3M ESPE, Saint Paul- MN, EUA) emicroparticulada Durafill (Heraeus Kulzer, Germany). Para cada resina foram confeccionados quinze corpos de prova com o auxílio de uma matriz aço inox com 7mm de diâmetro e 3 mm de espessura em dois incrementos e fotoativadas seguindo as orientações do fabricante. Os corpos de prova foram mantidos em água destilada a 37°C por 24 horas. Em seguida foram sub divididos em três grupos de acordo com protocolos de acabamento e polimento sendo avaliados o polimento com pontas Enhance® + PoGo (Dentsply, Konstanz, Germany), pontas Astropol (Ivoclar Vivadent, Schaan, Lienchtenstein) e discos Sof Lex Pop On (3M ESPE, Saint Paul- MN, EUA). Todos os espécimes foram submetidos à ciclagem térmica de 5 a 55 °C com tempo de imersão 1 minuto por 1000 ciclos. Após a ciclagem os espécimes foram submetidos a jato de bicarbonato (equipamento Ortusonic Ortus, Campo Mourão, PR, Brasil) por 30 segundos. A rugosidade de superfície foi avaliada com o auxílio de uma aparelho rugosímetro ( Mitutoyo SJ- 201P Mitutoyo Tokyo, Japão) em três momentos, sendo a primeira leitura, baseline, realizada após 24hs da confecção dos corpos de prova. A segunda, após o polimento dos corpos de prova e a terceira, após a profilaxia com jato de bicarbonato. A rugosidade foi medida em cinco locais diferentes em cada espécime. Os resultados foram analisados levando em consideração a rugosidade média (Ra), em micrômetros (m). Posteriormente foram realizadas análises ao microscópio eletrônico de varredura. De acordo com a metodologia empregada, conclui-se que a resina que apresentou maior rugosidade de superfície foi a microparticulada (Durafill), as menores rugosidades foram observadas nas resinas compostas nanoparticulada (Z350) e microhibrida (Z250). Os discos Sof Lex Pop On e as pontas Enhance e PoGo produziram superfícies mais lisas do que o sistema de polimento com as pontas Astropol, tais resultados podem ser confirmados com a análise em Microscopia Eletrônica de Varredura (M.E.V). / This in vitro study aimed to evaluate the occurrence of surface changes in three commercially available resin composites when subjected to polishing treatments and bicarbonate jet. The changes were quantified through roughness analysis and qualified by scanning electron microscopy. We tested three composites: nanoparticulated Z350 (3M ESPE, St. Paul, MN, USA), microhybrid Z250 (3M ESPE, St. Paul, MN, USA) e microparticuladed Durafill (Heraeus Kulzer, Germany). For each resin were prepared fifteen test specimens with the aid of a stainless steel matrix with 7mm diameter and 3 mm thick and photoactivated in two increments following the manufacturer\'s instructions. The specimens were kept in water at 37 ° C for 24 hours. Then were divided into three groups according to protocols being evaluated finishing and polishing polishing tips with Enhance ® + PoGo (Dentsply, Konstanz, Germany), tips Astropol (Ivoclar Vivadent, Schaan, Lienchtenstein) and Sof Lex Pop On disks (3M ESPE, St. Paul, MN, USA). All specimens were subjected to thermal cycling 5-55 ° C with a soak time of 1 minute per 1000 cycles. After cycling the specimens underwent bicarbonate jet (Ortusonic Ortus equipment, Campo Mourao, Parana, Brazil) for 30 seconds. The surface roughness was evaluated with the aid of a machine rugosimeter (Mitutoyo Mitutoyo SJ-201P Tokyo, Japan) in three stages, with the first reading, baseline, performed 24 hours after the making of the specimens. The second, after polishing the samples and the third, after prophylaxis with bicarbonate jet. The roughness was measured at five different locations on each specimen. The results were analyzed taking into account the average roughness (Ra) in micrometers (mm). Later analyzes were performed by scanning electron microscope. According to the methodology, it is concluded that the resin with the highest surface roughness was microparticulated (Durafill), the lowest roughness was observed in nanoparticled composites (Z350) and microhybrid (Z250). The Sof Lex Pop On disks and tips Enhance and PoGo produced smoother surfaces than polishing system with tips Astropol, these results can be confirmed with the analysis in Scanning Electron Microscopy (SEM).
30

Efeito do peróxido de carbamida em diferentes concentrações sobre a rugosidade superficial e brilho de uma cerâmica odontológica / The effect of carbamide peroxide in different concentrations on the surface roughness and gloss using dental ceramics

Roque, Ana Carolina Cabral 22 January 2016 (has links)
O gel de peróxido de carbamida é utilizado em concentrações que variam de 10 a 35%, por períodos de 2 a 8 horas diárias e seu efeito sobre os materiais restauradores ainda não está totalmente elucidado. Assim, o objetivo desse estudo foi avaliar a ação do peróxido de carbamida, 10 e 16%, sobre a rugosidade superficial e o brilho de uma cerâmica odontológica feldspática. Foram confeccionados espécimes (n=10), com a cerâmica IPS d.SIGN , que foram submetidos a protocolos de aplicação de gel de peróxido de carbamida a 10 e 16%, nos tempos de 4 ou 3 horas diárias respectivamente, pelo período de 14 dias. A determinação da rugosidade e da alteração de brilho foi realizada no início do tratamento, após 07 e após 14 dias. A rugosidade superficial foi determinada pelo microscópio, LEXT 3D Measuring Laser Microscope OLS4000, OLYMPUS, e a leitura do brilho foi feita pelo aparelho Micro Gloss. Após a obtenção dos dados, foi realizada a análise TwoWay ANOVA, verificou-se que o resultado obtido foi estatisticamente significante para a variável de rugosidade, tanto para os fatores de variação de tempo (p = 0,004), concentração do peróxido de carbamida (p = 0,007) e para a interação entre ambos (p = 0,013). Foi feito o teste de múltiplas comparações com ajustes de Bonferroni, para análise dos resultados obtidos. Na análise do brilho, para os resultados encontrados, não houve diferença estatisticamente significante. Assim, pode-se concluir que o peróxido de carbamida 10% não provocou alterações significativas na rugosidade da cerâmica, mas o peróxido de carbamida a 16% provocou aumento da rugosidade após o período de 14 dias de aplicação, com médias em torno de 4,0 μm. Conclui-se, então, que as restaurações cerâmicas devem ser protegidas antes da aplicação de agentes clareadores à base de peróxido de carbamida 10 ou 16%. / The carbamide peroxide gel is used in concentrations ranging from 10 to 35% for periods from 2 to 8 hours daily and its effect on the restorative material isnt yet fully elucidated. The objective of this study was to evaluate the action of carbamide peroxide, 10 and 16%, on the surface roughness and the gloss of a feldspathic dental ceramics. Specimens were prepared (n = 10), IPS d.SIGN ceramics and submitted to carbamide peroxide gel application protocols 10 and 16% at 4 or 3 hours, respectively, at time 14 days. The determination of roughness and gloss was made at baseline, after 07 and after 14 days. The surface roughness was determined by microscope, 3D Measuring Laser Microscope OLS4000 LEXT, OLYMPUS, and the reading of the gloss was taken by Micro Gloss device. After obtaining the data, the TwoWay ANOVA analysis was performed, it was found that the obtained result was statistically significant roughness variable, both for time-variant factor (p = 0.004), concentration of the carbamide peroxide (p = 0.007) and the interaction between both (p = 0.013). It was made for multiple comparisons test with Bonferroni adjustments, for analysis of the results.There was no statistically significant difference in gloss. Thus, it can be concluded that the carbamide peroxide 10% did not cause significant changes in roughness ceramic, but the carbamide peroxide at 16% caused an increased roughness after 14 days of application, averaging around 4, 0 micrometers. Therefore, the ceramic restorations must be protected before the application of bleaching agents based on carbamide peroxide 10 or 16%.

Page generated in 0.0368 seconds