• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 59
  • 18
  • 4
  • Tagged with
  • 80
  • 28
  • 17
  • 13
  • 13
  • 12
  • 11
  • 10
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Système coopératif radiofréquence de positionnement latéral d'un véhicule sur la chaussée / Radiofrequency cooperative system for lateral positioning of a vehicle on the roadway

Mohsen, Ibrahim 27 April 2017 (has links)
La recherche menée durant cette thèse a comme objectif de développer un système de positionnement latéral d’un véhicule sur sa voie de circulation afin d’alerter le conducteur en cas de sortie involontaire de sa voie ou de fournir à un système de conduite autonome la position latérale du véhicule. Le système développé est basé sur une interaction de type hyperfréquence entre un module d’émission-réception embarqué dans le véhicule et des transpondeurs passifs intégrés dans la chaussée entre chaque voies de circulation. Ce système fonctionne dans la bande UHF. Les transpondeurs passifs contiennent chacun une antenne connectée à deux résonateurs à onde acoustique de surface ayant des coefficients de qualité élevés à leur fréquence de résonance. Chaque transpondeur reçoit l’onde émise par le module hyperfréquence puis la réémet en lui ajoutant une signature spécifique venant des résonateurs. Le module hyperfréquence embarqué dans le véhicule contient des antennes d’émission et de réception ainsi qu’une chaine de transmission et d’acquisition. Il fonctionne autour des deux fréquences centrales des résonateurs. Un algorithme de traitement du signal reçu permet de déterminer la distance latérale entre le véhicule et les transpondeurs en utilisant les déphasages d’arrivé du signal du transpondeur après l’avoir extrait du signal global reçu. Le système a été expérimenté en milieu extérieur et il présente une erreur d’estimation de la distance latérale d’environ 4cm. / The research carried out during this thesis aims to develop a lateral positioning system of a vehicle on its lane in order to alert the driver in case of an unintentional lane departure or to provide the lateral position of the vehicle for an autonomous driving system. The system developed is based on a hyperfrequency interaction between a transceiver module embedded in the vehicle and passive transponders integrated in the road. This system operates in the UHF band. Each passive transponder contains an antenna connected to two surface acoustic wave resonators that have a high quality coefficient at their resonant frequency. Each transponder receives the waves emitted by the hyperfrequency module and then retransmits it by adding a specific signature due to the resonators. The hyperfrequency module embedded in the vehicle contains transmitting and receiving antennas as well as a transmission and acquisition chain. It operates around the two center frequencies of the resonators. A received signal processing algorithm was devemoped to determine the lateral distance between the vehicle and the transponders by using the phase of the transponder signal after having extracted it from the received global signal. The system has been tested in an external environment and has an estimated lateral distance error of 4 cm.
22

Caractérisation du phosphore noir pour des applications optoélectroniques hyperfréquences / Black phosphorus characterization for optoelectronic applications at high frequency range

Penillard, Anne 09 March 2018 (has links)
Les dispositifs à base de silicium, industrialisés aujourd’hui pour les systèmes électroniques, atteignent leurs limites en termes de miniaturisation et de performances. La course à l’innovation et à la miniaturisation vise aujourd’hui à dépasser cette limite en intégrant de nouveaux matériaux dans les dispositifs, en couplant d’autres phénomènes physiques de l’optique à l’électronique haute fréquence. Le travail conduit pendant cette thèse porte sur la caractérisation du phosphore noir (bP) pour des applications dans le domaine de l'optoélectronique hyperfréquence avec une application spécifique aux interrupteurs microondes pilotés optiquement à 1,55 µm. La caractérisation du bP passe par le développement de techniques de fabrication de couches bidimensionnels de bP et également par la détermination de l'influence des matériaux annexes utilisés sur les propriétés de la couche. Cela a été couplé à une étude optique pour connaitre la réponse du bP à une excitation laser à 1,55 µm. La détermination de paramètres intrinsèques spécifiques du matériau tels que le temps de vie des photoporteurs, la résistivité et la permittivité a été conduite par l'intermédiaire d'expériences de caractérisation dans le domaine optique, radiofréquence et électronique (DC). Les résultats obtenus confirment l’intérêt du bP pour ce genre d'application et ont permis l'intégration du matériau dans le dispositif hyperfréquence visé. Les résultats obtenus lors de tests préliminaires présentés dans ce mémoire sont très encourageants et ouvre la voie à de nombreuses applications ultra-rapide à haute fréquence. / The research project conducted focuses on the optoelectronic and high frequency characterization of black phosphorus. The context of this project is the trend of downscaling and multi-physical coupling seen today in industrial electronics. The characterization carried out is directed for a specific application, the realisation of microwave photoswitch controlled by a laser optical excitation at 1.55 µm. For this purpose, during this PhD a production process of thin and large bi-dimensional layers of black phosphorus has been performed, along with the fabrication of characterization devices, and a discussion to determine suitable appendices for substrate, capping layer and metallization. The technological development is coupled with optical, electronic (DC) and radiofrequency characterizations of the bi-dimensional layers for the determination of inherent black phosphorus properties like the photogenerated carrier lifetime, the material permittivity, the resistivity and the mobility of the carriers. Those parameters are essential to understanding design and simulate high frequency optoelectronic devices on black phosphorus such as the microwave photoswitch controlled at 1.55 µm. The obtained results assert black phosphorus as a promising material for this kind of application. The first performances obtained with the use of bP as an active material for photoconductive switching are very encouraging and open the way for high frequency and high speed applications.
23

Récepteurs RF large-bande à échantillonnage et numérisation directs / Broadband direct RF digitization receivers

Jamin, Olivier 15 March 2013 (has links)
Les communications numériques ont évolué pour répondre à la demande des consommateurs pour accroître l'accès à la navigation Internet, TV, vidéo à la demande, jeux interactifs et de réseaux sociaux. Cette augmentation de débit est obtenue en utilisant des techniques avancées de traitement du signal, des modulations complexes, et des bandes passantes larges. Par conséquent, des récepteurs hautes performances, capables de traiter des signaux large bande, sont nécessaires pour les équipements d'infrastructure et de communication grand-public hauts de gamme. Les récepteurs à numérisation directe RF sont attrayants pour ces applications à large bande, mais plusieurs aspects doivent être étudiés afin de fournir des solutions performantes intégrées. Les principales contributions de cette thèse sont les suivantes: - l’analyse et la conception au niveau système des récepteurs à échantillonnage et numérisation directs RF : - l'analyse théorique de la distorsion non-linéaire large-bande, pour les stratégies d'échantillonnage passe-bas et passe-bande - l'analyse théorique des défauts des convertisseurs analogique-numérique haute-vitesse dans un contexte de réception large bande - la conception d'un conditionneur de signal RF optimisé pour une application câble, incluant: - un égaliseur RF programmable multi-pente, utilisant une seule inductance, avec son algorithme de contrôle - une boucle de contrôle de gain mixte combinant un détecteur RMS et un détecteur crête - contribution à la réalisation d'un produit récepteur RF multi-canaux, à numérisation directe, compétitif en consommation d'énergie, coût, et performances RF / The Holy Grail radio receiver architecture for Software Radio makes uses of direct RF digitization. The early RF signal digitization theoretically provides maximum re-configurability of the radio front-end to multiple bands and standards, as opposed to analog-extensive front-ends. In addition, in applications for which a large portion of the RF input signal spectrum is required to be received simultaneously, the RF direct digitization architecture could provide the most power-and-cost-effective front-end solution. This is typically the case in centralized architectures, for which a single receiver is used in a multi-user environment (data and video gateways) or in re-multiplexing systems. In these situations, this highly-digitized architecture could dramatically simplify the radio front-end, as it has the potential to replace most of the analog processing. In this Ph.D thesis, we study the trade-offs, from RF to DSP domains, which are being involved in direct RF digitization receivers. The developed system-level framework is applied to the design of a cable multi-channel RF direct digitization receiver. Special focus is provided on the design of an optimum RF signal conditioning, on the specification of time-interleaved analog-to-digital converter impairments, including clock quality, and on some algorithmic aspects (automatic gain control loop, RF front-end amplitude equalization control loop). The two-chip implementation is presented, using BiCMOS and 65nm CMOS processes, together with the block and system-level measurement results. The solution is highly competitive, both in terms of area and RF performance, while it drastically reduces power consumption.
24

Development and optimization of mechanical polishing process for superconducting accelerating cavities / Développement et optimisation d'un procédé de polissage mécanique pour les cavités accélératrices supraconductrices

Hryhorenko, Oleksandr 13 December 2019 (has links)
La production de masse de cavités accélératrices supraconductrices en régime radiofréquence (SRF) est un réel défi industriel non seulement du fait du nombre croissant de cavité pour les futurs grands projets mais également de par les besoins en terme de fiabilité, reproductibilité et performances demandées très proches des limites physiques du Niobium. De nos jours, XFEL (DESY) et le LHC (CERN) sont les deux accélérateurs les plus importants utilisant la technologie supraconductrice. Des projets accélérateurs encore plus ambitieux, tels que l’ILC (International Linear Collider) et FCC (Future Circular Collider) sont en cours d’étude. Pour de tels projets, il est encore nécessaire d’améliorer les performances et de réduire les coûts de fabrication et d’opération avant d’engager la phase d’industrialisation.Une voie d’amélioration des performances et de réduction des coûts a été étudiée. Ceci consiste à améliorer les procédés de nettoyage des surfaces. En effet, la pollution et les dommages causés à la structure cristalline durant la fabrication d’une cavité supraconductrice doivent être impérativement retirés afin de garantir des performances optimales. Cette régénération des surfaces est couramment réalisée à l’aide de deux types de polissages chimiques : par BCP (Buffered Chemical Polishing) ou par électro-polissage (EP). Cependant, ces techniques utilisent des acides très concentrés qui entrainent des coûts d’opération très conséquents du fait des problèmes de sécurité. Une voie d’amélioration pouvant rendre possible la construction de telles machines serait de remplacer totalement ou partiellement l’utilisation des acides par des techniques de polissage alternatives.Le polissage mécanique a été étudié durant des décennies et plus spécifiquement les techniques par centrifugation (CBP). Cette technique permet d’atteindre des rugosités de surface bien meilleures et est bien plus efficace pour retirer certains défauts de surface comparé aux procédés chimiques. Cependant, cette technique n’est pas envisageable comme solution alternative à cause des fortes pollutions de surface et des durées de traitement très longues. La première partie de la thèse a consisté à reproduire l’état de l’art, comprendre les limitations réelles de cette technique et essayer d’améliorer le procédé en réduisant la pollution de surface générée par le piégeage des abrasifs en surface ainsi que la durée de traitement (réduction du nombre d’étapes intermédiaires). Il a été conclu que ce procédé ne peut pas être considéré comme alternatif mais complémentaire aux traitements chimiques.La deuxième partie du travail de thèse s’est concentrée sur la méthode de polissage métallographique. Cette dernière ne peut s’appliquer que sur plaques et non sur des géométries complexes, cependant elle retire très efficacement toutes les impuretés et dommages cristallins formés durant la fabrication des tôles de Niobium. Un procédé optimisé à 2 étapes, inspiré des techniques conventionnelles (typiquement 5-6 étapes) a été développé avec succès et optimisé pour les contraintes particulières du Niobium pour les applications SRF. Ce procédé permet non seulement d’obtenir une rugosité de surface incomparable mais préserve également la structure cristalline. Des études complémentaires sont encore requises afin d’améliorer les techniques de formage des tôles ou même caractériser des solutions alternatives permettant des limiter les dégâts en surface et de préserver la qualité du matériau.Finalement, ce travail mené est d’une importance capitale pour le futur des cavités accélératrices supraconductrices, c’est-à-dire l’utilisation de nouveaux matériaux supraconducteurs sous forme de couche mince. La qualité des couches minces de ces matériaux alternatifs dépend très fortement de l’état de surface du substrat (typiquement niobium ou cuivre poly cristallin). / Large-scale production of superconducting radio-frequency (SRF) cavities is an industrial challenge, not only because of the increasing number of unit for future projects but also because of requirements in term of reliability, reproducibility and performances very close to the physical limit of polycrystalline bulk Niobium. Nowadays, XFEL (DESY) and LHC (CERN) are the largest existing accelerators which are based on SRF technology. Even more challenging SRF accelerator projects like ILC (International Linear Collider) and FCC (Future Circular Collider) are being studied. For such large-scale facilities, higher performances, reduction in fabrication and operation costs are required and essential to proceed with industrialization.A pathway to reduce these costs and improve performances has been studied in this work. It consists in optimizing the cleaning process of cavity surfaces. Indeed, pollution and crystal defects on the surface created during fabrication steps of a SRF cavity have to be removed to ensure optimal superconducting performances. In order to get rid of impurities and to recover crystal structure, two polishing techniques are routinely used: the buffered chemical polishing (BCP) and electro-polishing (EP). However, these techniques involve highly concentrated acids, which lead to high operation costs and safety concerns. A way to overcome the aforementioned drawbacks and make the construction of future accelerators possible would be to replace or complement the conventional chemical polishing by alternative polishing techniques.Mechanical polishing has already been applied in SRF-community for decades by using centrifugal barrel polishing (CBP). This technique could provide a better surface roughness and could be more efficient at removing some surface defects compared to EP and BCP. However, this process does not satisfy requirements for large-scale production due to strong surface pollution and an extremely long processing time. The first part of the PhD work consisted in reproducing the state of the art, understanding its limitations and optimizing the recipe by the reduction of the surface pollution (embedded abrasives) and processing time (reduction of intermediate steps). As a conclusion to this first study, CBP could only be a complementary polishing technique to chemical treatments.The second part of the work focused on metallographic flat polishing. This technique cannot be directly applied on enclosed geometries however, it can remove efficiently surface defects (impurities and crystal damages) created during the fabrication of Niobium sheet. A 2-step process, inspired from metallographic techniques (typically 5-6 steps) has been successfully developed and optimized on Niobium for SRF applications. This process provides not only an improved roughness compared to conventional chemical treatments but also preserve the crystal quality underneath the surface, over the field penetration depth. Additional studies have to be now carried out to optimize conventional forming process or characterize alternative techniques to limit surface damages and preserve material quality as much as possible.Last but not least, the work done is of first importance for the future of SRF cavities meaning the use of new superconducting materials as thin films. The quality of thin-films of alternative superconductors depends strongly on the surface state of the substrate, typically polycrystalline bulk Niobium or Copper.
25

Dynamic magnetic resonance spectroscopy of phosphate energetics during muscle exercise and recovery

Sabouri, Bahare 12 1900 (has links)
Entailing of phosphorus exchanges in most bio-chemicals as a key factor in disease, increases researcher’s interest to develop the technologies capable of detecting this metabolite. Phosphorus magnetic resonance spectroscopy is able to detect key metabolites in a non-invasive manner. Particularly, it offers the ability to measure the dynamic rate of phosphocreatine(PCr) degeneration through the exercise and recovery. This metric as a valid indication of mitochondrial oxidative metabolism in muscle, differentiate between normal and pathological state. To do magnetic resonance imaging and spectroscopy, clinical research tools provide a wide variety of anatomical and functional contrasts, however they are typically restricted to the tissues containing water or hydrogen atoms and they are still blind to the biochemicals of other atoms of interests. Through this project we intended to obtain the phosphorus spectrum in human body – specificadenerativelly in muscle – using 31P spectroscopy. To do so a double loop RF surface coil, tuned to phosphorus frequency, is designed and fabricated using bench work facilities and then validated through in vitro spectroscopy using 3 Tesla Siemens scanner. We acquired in vitro as well as in vivo phosphorus spectrum in a 100 mM potassium phosphate phantom and human calf muscle in rest-exercise-recovery phase in a 3T MR scanner. The spectrum demonstrates the main constituent in high-energy phosphate metabolism. We also observed the dynamic variation of PCr for five young healthy subjects who performed planter flexions using resistance band during exercise and recovery. The took steps in this project pave the way for future application of spectroscopic quantification of phosphate metabolism in patients affected by carotid artery disease as well as in age-matched control subjects. / L’importance des échanges de phosphore liés à l’apparition de troubles et de maladies neurodégénèratives a suscité l’intérêt des chercheurs en ce qui concerne le développement de technologies pouvant détecter ces composés métaboliques. Á l’aide de la spectroscopie en résonance magnétique du phosphore, il est possible de détecter ces métabolites d’une manière non-invasive. Cette technique permet plus particulièrement de mesurer le taux de degénération de la phosphocréatine (PCr) lors de périodes d’exercice et de récupération post-activité. Cette dernière métrique agit en tant qu’indicateur valide du métabolisme oxydatif mitochondrial dans le muscle et permet de différentier un muscle sain d’un muscle pathologique. Pour effectuer l’imagerie ou la spectroscopie par résonance magnétique, de nombreux outils cliniques peuvent être utilisés afin de générer des images comprenant une variété de contrastes anatomiques et fonctionnels. Par contre, ces contrastes ne peuvent être habituellement produits qu’à partir des molécules d’eau ou des atomes d’hydrogène renfermés dans les tissus biologiques et les outils permettant de générer les images correspondantes demeurent, pour la plupart, insensibles à la présence d’autres atomes d’intérêt. Au cours de ce projet, il a été question d’obtenir un spectre du phosphore à partir de l’activité musculaire chez l’humain in vivo en se servant de la technique de spectroscopie de type 31P. Pour ce faire, une antenne radiofréquence à deux canaux, devant être syntonisée à la fréquence de résonance du phosphore, a d’abord été conçue et fabriquée en laboratoire pour ensuite être validée lors d’expériences sur une plateforme IRM 3T de marque Siemens. Les spectres du phosphore furent acquis sur un fantôme, une solution de phosphate de potassium à une concentration de 100 mM, ainsi que sur le mollet d’un sujet humain au cours d’une période de repos, d’exercice et de récupération. Le spectre obtenu à la suite de cette dernière expérience démontre la présence accrue du phosphore lors de procédés métaboliques à haute teneur énergétique impliquant la dégradation de phosphates. Par la suite, il a été question d’observer la variation des niveaux de PCr durant des périodes d’exercice et de récupération chez 5 jeunes adultes effectuant une série iv de flexions plantaires ayant un élément résistif attaché à leurs pieds. La démarche entreprise au cours de ce projet permettra l’utilisation future des techniques quantitatives en spectroscopie pour l’évaluation du métabolisme des phosphates chez des patients souffrant de maladies coronariennes ainsi que chez des sujets contrôles sains provenant du même ensemble démographique.
26

Conception de circuits intégrés radiofréquences reconfigurables en technologie FD-SOI pour application IoT / Design of tunable radiofrequency blocks in FD-SOI technology for IoT applications

Desèvedavy, Jennifer 08 October 2018 (has links)
La pénétration importante d’objets communicants dans notre vie quotidienne révèle des défis important quant à leur développement. Notamment l’explosion d'applications multimédia sans fil pour l'électronique grand public fait de la consommation électrique une métrique clef dans la conception des dispositifs portables multimodes sans fil. Les émetteurs-récepteurs conventionnels proposent des performances fixes et sont conçus pour respecter ces hautes performances dans toutes les conditions de communication sans fil. Cependant, la plupart du temps, le canal n'est pas dans le pire cas de communication et ces émetteurs-récepteurs sont donc surdimensionnés. En connaissant l’état du canal en temps réel, de tels dispositifs pourraient s'adapter aux besoins et réduire significativement leur consommation électrique. Le défi consiste à respecter la Qualité de Service , ou Quality of Service (QoS) en anglais, imposée par les différents standards de communication. Afin de rester compétitifs, les émetteurs-récepteurs adaptatifs doivent donc proposer une même QoS que ceux déjà disponibles sur le marché. Ainsi, ni la portée de communication ni le temps de réponse ne peuvent être dégradés.Basé sur ces exigences, cette thèse propose une technique d'adaptation pour la conception d'un récepteur reconfigurable qui fonctionne à la limite des performances nécessaires pour recevoir le signal utile. Ainsi, le récepteur proposé est toujours au minimum de consommation électrique tout en garantissant la bonne QoS. Ceci permet alors de multiplier la durée de vie de sa batterie par un facteur 5.Cette adaptabilité est démontrée ensuite côté circuit par la conception d'un LNA (Amplificateur Faible Bruit) dont les performances sont reconfigurables. En effet, en tant que premier élément de la chaîne de réception, le LNA limite le récepteur en termes de sensibilité. Ces travaux exploitent la technologie FD-SOI (Fully Depleted Silicon-On-Insulator) pour d’une part, réduire la consommation du LNA et d’autre part, ajouter de la reconfigurabilité à ce même circuit. / Communicating objects are inviting themselves into daily life leading to digitization of the physical world. This explosion of multimedia wireless applications for consumer electronics makes the power consumption a key metric in the design of multi-mode wireless portable devices. Conventional transceivers have fixed performances and are designed to meet high performances in all wireless link conditions. However, most of the time, the channel of communication is not at worst case and these transceivers are therefore over specified. Being aware of the channel link conditions would allow such devices to adapt themselves and to reduce significantly their power consumption. Therefore, the challenge is to propose a QoS (Quality of Service) in terms of communication range, response time as instance, equivalent to industrial modules with a reduced overall power consumption.To address this purpose, this thesis proposes a design strategy for the implementation of adaptive radio-frequency receiver (Rx) modules. Hence the Rx front end achieves the correct QoS for various scenarii of communications with a minimum of power consumption.As a proof of concept, the adaptive approach is demonstrated with the design of a tunable LNA (Low Noise Amplifier). As the first element of the receiver chain, the LNA limits the receiver in terms of sensitivity and is therefore a good candidate to perform reconfiguration. The body biasing of the FD-SOI (Fully Depleted Silicon-On-Insulator) technology is first exploited to reduce the power consumption of a circuit and then as an opportunity to perform circuit tunability.
27

Étude des interactions par radiofréquence entre multiples dispositifs médicaux pour la compatibilité IRM / A study of radiofrequency interactions between multiple medical devices for MRI compatibility

Kabil, Julie 11 January 2018 (has links)
Avec une population mondiale vieillissante, de plus en plus de personnes sont à risque de présenter des pathologies pour lesquelles l’Imagerie par Résonance Magnétique (IRM) est une modalité de choix : ainsi, le nombre d’examens IRM est en constante augmentation. Les patients âgés étant par ailleurs une population davantage susceptible de recevoir une implantation de dispositifs médicaux (tels qu’un pacemaker ou une prothèse de hanche), la sécurité des patients implantés en IRM est primordiale. En effet, cet appareil d’imagerie médicale fait intervenir différents champs électromagnétiques pouvant interagir avec un implant métallique et donner lieu à des risques potentiels pour le patient. Si des normes de compatibilité existent aujourd’hui pour soumettre individuellement les dispositifs médicaux à des tests standardisés et assurer leur innocuité en environnement IRM, les interactions entre multiples dispositifs médicaux vis-à-vis des ondes électromagnétiques radiofréquence (et des dangers qui peuvent en résulter) sont un domaine complexe qu’il est nécessaire de comprendre. L’objet de cette thèse est d’étudier ces interactions sur plusieurs niveaux : interactions intra-dispositif, interactions inter-dispositifs et interactions entre dispositif et plusieurs antennes. Une méthode de prédiction d’échauffement a été proposée pour simplifier l’étude de larges gammes d’implants, suivant les variations de paramètres caractérisant les différentes parties au sein d’une prothèse. Des simulations électromagnétiques et thermiques, associées à des mesures expérimentales dans un environnement IRM clinique, ont permis de mettre en évidence des phénomènes de couplages entre deux implants simplifiés et d’introduire une nouvelle métrique pour les quantifier. Enfin, une étude multi-antennes a fourni des éléments de réponse à la question de la sécurité d’un patient implanté en présence de plusieurs antennes, dans une configuration semblable à celle des examens en routine clinique. Les travaux présentés dans cette thèse ont ainsi permis d’évaluer les interactions vis-à-vis de la radiofréquence de l’IRM en présence d’un ou plusieurs dispositifs médicaux et antennes, ouvrant plusieurs perspectives pour aller vers une IRM sûre pour tous / With an aging population worldwide, more and more persons are at risk of suffering from pathologies which are best diagnosed or monitored with Magnetic Resonance Imaging (MRI): thus, the number of MRI exams is constantly increasing. Moreover, elderly patients being likely to undergo a medical device implantation (such as a pacemaker or a hip prosthesis) the safety of implanted patient in MRI is crucial. The medical imaging technique involves indeed different electromagnetic fields which can interact with a metallic implant and lead to potential hazard for the patient. Even though compatibility guidelines exist today to subject individually medical devices to standardized tests and ensure their harmlessness in an MRI environment, the interactions between multiple medical devices with respect to radiofrequency electromagnetic waves (and to the hazards that may follow) are a complex research area that has to be understood. The aim of this thesis is to study these interactions on different levels: intra-device interactions, inter-devices interactions and interactions between a device and several antennas. A prediction method has been proposed to simplify the study of large range of implants, according to the variations of parameters characterizing the different parts of a prosthesis. Electromagnetic and thermal simulations, associated with experimental measurements in a clinical MRI environment, allowed to highlight a coupling phenomenon between two simplified implants and to introduce a new metric to quantify them. Finally, a multi-antenna study led to some insights to answer the question of the safety of an implanted patient with several antennas, in a configuration similar to a clinical routine exam. Thus, the research work presented in this thesis allowed to assess the interactions with respect to MRI radiofrequency in presence of one or several medical devices and antennas, opening new prospects towards a safe MRI for everyone
28

Verres pour la Photostructuration

Maurel, Clément 10 February 2009 (has links) (PDF)
Les besoins de nouvelles technologies en télécommunications motivent la recherche de matériaux participant à la formation de composants optiques. Dans ce but, l'étude de la photostructuration de nouvelles formulations de verres possédant des propriétés optiques ajustables a été réalisée. Deux cas ont été étudiés : la modification du réseau vitreux ou l'introduction d'ions photosensibles au sein du verre. - Des verres oxysulfures de germanium et de gallium ont été élaborés sous forme de massif, et sous forme de couche mince. Leurs propriétés optiques sont intermédiaires à celles des composés purs Ge(Ga)O2 et Ge(Ga)S2. La photosensibilité des verres diminue avec l'augmentation de la valeur du rapport O/S des matériaux. - L'ajout d'ions argent au sein de verres phosphates de zinc a été étudié. Plusieurs techniques de réduction de l'ion argent dans ces verres ont été explorées comme l'irradiation par faisceau électronique, par rayonnement gamma ou par Laser. Dans le cas particulier d'une irradiation par laser femtoseconde de cadence de 8 Mhz et émettant à 1030 nm, il a été possible de créer des structures optiques de 85 nm environ, donc bien inférieur à la longueur d'onde utilisée pour l'écriture. Ces premiers résultats offrent une nouvelle alternative à la création dans le futur de structures photoniques composites.
29

VERRES CHALCOGENURES POUR L'OPTIQUE INTEGREE

BALAN, Viorel 03 December 2003 (has links) (PDF)
L'intérêt des guides d'onde à base de couches minces chalcogénures pour des applications dans l'infrarouge comme la métrologie de l'environnement, l'amplification optique ou l'interférométrie spatiale est démontré. La réalisation de ces guides par empilement et gravure de couches non dopées ou dopées erbium est ensuite décrite, étape par étape. La première d'entre elles a consisté à acquérir la maîtrise du dépôt des verres chalcogénures purs par pulvérisation cathodique radiofréquence. Des films de bonne qualité et aux propriétés reproductibles ont pu être obtenus. La dépendance des propriétés des films en fonction de leur épaisseur a été mise en évidence. La deuxième étape concerne le dopage erbium des couches minces chalcogénures, pour la réalisation de composants actifs. L'introduction de l'erbium sous sa forme optiquement active Er(3+) a pu être mise en évidence par la présence du phénomène de photoluminescence dans les couches. Les premières mesures de durées de vie sont par ailleurs très encourageantes. La troisième étape de la réalisation des guides d'onde est la gravure des couches guidantes : trois types de gravure (gravures chimique, sous plasma inerte et sous plasma réactif) ont été testés et comparés. Des marches de bonne qualité ont pu être obtenues par chacune de ces trois méthodes. La dernière étape décrite dans ce manuscrit est la réalisation et la caractérisation des guides proprement dits : deux types de guide (TIR et ARROW) ont été réalisés et testés avec succès.
30

Contrôle du profil de courant par ondes cyclotroniques électroniques dans les tokamaks

Dumont, Rémi 03 July 2001 (has links) (PDF)
L'injection d'ondes radiofréquence dans un plasma de tokamak afin d'y générer le courant toroïdal répond à une double exigence. Premièrement, la nature non inductive de la méthode évite le recours aux courants variables circulant dans les bobines, peu compatibles avec l'opération stationnaire d'un futur réacteur. Par ailleurs, il est reconnu que la principale limitation des performances d'un plasma de fusion est causée par la turbulence électromagnétique. Celle-ci peut toutefois être réduite, voire supprimée, en optimisant le profil de courant, ce qu'autorise précisément l'emploi des ondes, dans le cadre des scénarios avancés. Cette thèse traite de l'utilisation de l'onde cyclotronique électronique (EC) en vue de contrôler le profil de courant. S'agissant d'une question cruciale conditionnant l'usage de cette onde dans les plasma chauds, l'effet de la température finie sur la polarisation de l'onde est d'abord étudié dans divers régimes. D'autre part, dans les scénarios avancés, l'association des ondes EC et hybride basse (LH) est prometteuse, du fait de leurs caractéristiques complémentaires. Une large partie de ce travail est donc consacrée à l'étude théorique, numérique et expérimentale des décharges combinées. Les résultats obtenus, parmi lesquels la démonstration analytique d'un effet de synergie entre les deux ondes, montrent clairement l'intérêt de ces scénarios et motivent la mise au point de nouvelles expériences.

Page generated in 0.4359 seconds