• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 59
  • 18
  • 4
  • Tagged with
  • 80
  • 28
  • 17
  • 13
  • 13
  • 12
  • 11
  • 10
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Chimiosensibilisation de l’adénocarcinome canalaire du pancréas par la perturbation du microenvironnement tumoral et l’augmentation de la biodisponibilité dans la cellule tumorale : effets de la cavitation ultrasonore et de l’inhibition de nrf2 / Innovative pathways of chemosensitization in pancreatic ductal adenocarcinoma : acoustic cavitation and NRF2 inhibition

Camus Duboc, Marine 24 November 2017 (has links)
L’adénocarcinome pancréatique (AP) connaît une forte augmentation d’incidence, qui en fait la quatrième cause de mortalité par cancer avec un pronostic extrêmement sombre, moins de 5% des patients étant en vie à 5 ans. De nombreuses avancées dans la compréhension de l’oncogénèse pancréatique notamment sur les aspects génétiques, immunitaires et sur les interactions cellulaires du stroma tumoral ont permis d’envisager le développement de nouvelles stratégies de traitement. Cependant malgré des résultats pré-cliniques très encourageants aucune de ces stratégies n’a encore permis l’émergence d’un traitement plus efficace que la chimiothérapie standard. Ce travail de thèse a abordé 2 approches thérapeutiques innovantes distinctes mais potentiellement complémentaires dans le traitement de l’adénocarcinome pancréatique en étudiant in vitro (cultures cellulaire 2D et 3D) et in vivo (modèles ectopiques et orthotopiques) les effets sur la croissance tumorale de l’inhibition d’un acteur important du stress oxydant (la voie Nrf2) d’une part, de la combinaison d’une chimiothérapie liposomale et d’un agent physique, la cavitation ultrasonore, d’autre part. La cavitation ultrasonore est un effet mécanique des ultrasons permettant d’augmenter l’internalisation de molécules ou de gènes dans les cellules. Dans cette thèse, la faisabilité et l'efficacité de la combinaison d’une chimiothérapie liposomale ciblée par la cavitation ultrasonore a été évaluée dans des modèles murins orthotopiques d’AP. Un système de délivrance d’ultrasons a été adapté afin d’appliquer une cavitation inertielle focalisée sur des xénogreffes d’AP créées après l'injection de doxorubicine liposomale (L-DOX) selon une étude pharmacocinétique préliminaire réalisée dans un modèle murin. La L-DOX, conçue à base de phospholipides non saturés de dioleoylphosphatidyléthanolamine, connue pour être stable dans la circulation sanguine, a été choisie afin de maximiser son accumulation et le relargage du principe actif lors de la délivrance des ultrasons. Nous montrons que l’association de la L-DOX à la cavitation inertielle permet de réduire in vivo le volume tumoral dans un modèle orthotopique d’AP chez la souris nude. La cavitation inertielle peut donc augmenter l'effet antitumoral des liposomes porteurs de chimiothérapie avec un effet mécanique minimal sur le tissu environnant la tumeur.Des études récentes suggèrent que Nrf2 est une cible de choix pour vaincre la chimiorésistance de l’AP. Des méthodes in vitro et in vivo ont été utilisées afin d’examiner l'effet du brusatol associé à des agents chimiothérapeutiques de référence sur la mort cellulaire et son impact sur le stress oxydant. Nous montrons que l’inhibition de la voie Nrf2 par le brusatol, un composé naturel issu de Fructus Bruceae, potentialise les effets de la chimiothérapie et permet l’inhibition de la croissance tumorale in vitro sur des lignées cellulaires d’AP cultivées en 2D et 3D. Cette inhibition s’accompagne d’une modulation du stress oxydant dont témoignent l’augmentation des espèces réactives de l’oxygène (ROS) et la diminution du glutathion (GSH). In vivo, la combinaison du brusatol et de l'oxaliplatine a réduit le volume tumoral dans deux modèles murins de xénogreffe d’AP. Ces résultats suggèrent l'efficacité du brusatol pour lutter contre la chimiorésistance et renforce l’hypothèse d’un rôle clinique potentiel de l’inhibition de Nrf2 comme adjuvant à la chimiothérapie dans l’AP. Un travail clinique a également été mené en parallèle sur une modalité de traitement physique innovante, la radiofréquence endobiliaire, dans la prise en charge endoscopique de l’ampullome vatérien, tumeur rare à la croisée entre le tube digestif et le système biliopancréatique. Les résultats de cette étude prospective multicentrique seront également présentés dans cette thèse. / Pancreatic ductal adenocarcinoma (PDAC) has increased in incidence over the past decade, leading it to be the fourth lethal cause of cancer in the world with a very poor prognosis, since less than 5% of patients are alive at 5 years. Many advances in the understanding of pancreatic tumorigenesis, notably on the genetic, immune and cellular stroma interactions of the tumor, have led to the development of new treatment strategies in the last decade. However, despite very encouraging pre-clinical results, none of these strategies has yet led to the emergence of a truly effective treatment in comparison with standard chemotherapy. This thesis focused on two innovative therapeutic modalities in the treatment of PDAC at a preclinical stage by studying in vitro (2D and 3D cell cultures) and in vivo (ectopic, orthotopic xenografts) the effects on the tumor growth of an inhibitor of the Nrf2 pathway (involved in oxidative stress), on the first hand, and of a physical element, ultrasound cavitation associated with liposomal chemotherapy, on the second hand. Ultrasound cavitation is a mechanical effect of ultrasound to increase the uptake of molecules or genes in cells. The feasibility and effectiveness of the combination of liposomal chemotherapy targeted by ultrasonic cavitation was evaluated in murin orthotopic models of PDAC. An ultrasound delivery system has been adapted to apply focused inertial cavitation to PDAC xenografts created after the injection of liposomal doxorubicin (L-DOX) according to a preliminary pharmacokinetic study carried out in the murine model. L-DOX, designed on unsaturated phospholipids of dioleoylphosphatidylethanolamine, was known to be stable in the bloodstream and to maximize its accumulation and release of the active drug during ultrasound delivery. This thesis shows that this therapeutic combination (L DOX and inertial cavitation) makes it possible to reduce the tumor volume in vivo in a nude mouse orthotopic model of PDAC. Inertial cavitation may be generated to increase the therapeutic effect of chemotherapybearing liposomes accumulated in the tumor with minimal mechanical effect on the surrounding tissue. Recent studies strongly suggest that Nrf2 is an ideal target against chemoresistance of PDAC. In vitro and in vivo methods were combined to examine the effect of brusatol associated with chemotherapeutic agents on cell death in addition to its impact on oxidative stress (reactive oxygen species and gluthation levels). This thesis demonstrates that the inhibition of the Nrf2 pathway via brusatol, a natural compound derived from Fructus Bruceae, potentiates the effects of chemotherapy and allows the inhibition of tumor growth in vitro on PDAC cell lines. This inhibition is accompanied by a modulation of oxidative stress by brusatol, with increasing ROS and decreasing GSH. In vivo, the combination of brusatol and oxaliplatin reduced tumor volume in two mouse models of PDAC xenograft. These results suggest the efficacy of using brusatol to combat chemoresistance and reinforce the idea that brusatol could be developed as an adjuvant to chemotherapy in PA. Clinical work was also carried out in parallel on an innovative physical treatment modality, endobiliary radiofrequency, in the management of adenoma of the ampoule of Vater, a rare tumor located between the digestive and the bilio-pancreatic systems. The results of this work will also be presented in this thesis.
62

Analyse et détection des électrogrammes complexes fractionnés en vue de soigner la fibrillation auriculaire à l'aide de techniques d'ablation par radiofréquence

Navoret, Nicolas 26 June 2013 (has links) (PDF)
Ce manuscrit présente des travaux de recherche sur l'analyse et la détection des Electrogrammes Auriculaires Complexes Fractionnés (EACF). Dans une première partie faisant suite à une présentation des mécanismes et des signaux bioélelectriques de la Fibrillation Auriculaire (FA), les outils les plus couramment utilisés pour l'analyse des signaux EACF sont présentés. Des outils linéaires sont dans un premier temps appliqués aux signaux intracardiaques issus des procédures d'ablation de la FA par radiofréquence puis des outilsnon linéaires sont présentés et intégrés à un algorithme de détection des EACF. Ce dernier s'appuie sur la quantification des propriétés de récurrence des électrogrammes. Dans la seconde partie, la cellule et le tissu musculaire cardiaque sont détaillés puis simulés à l'aide de plusieurs modèles mathématiques. Ceux de FitzHugh Nagumo, Aliev Panfilov et Courtemanche Ramirez Nattel sont mis en oeuvre afin de reproduire les mécanismes de la FA évoqués dans la présentation de cette pathologie. L'acquisition des champs de potentiels est également reproduite à l'aide d'un modèle numérique de cathéter tel que celui utilisé lors des procédures. Les signaux temporels ainsi générés permettent de lier les activations spatiotemporelles au niveau du substrat aux motifs observables dans les EACF. Un modèle expérimental vient compléter la partie modélisation. Les cultures de cellules de rats nouveaux nés sur puces MEA (Micro Electrode Array) permettent de recréer des conditions de fibrillation et d'acquérir des potentiels extracellulaires. Là encore, les électrogrammes sont comparés aux signaux issus des simulations numériques ainsi qu'aux signaux cliniques. L'analyse des séquences de motifs via les trois types de modèles utilisés permet de rattacher les motifs observés dans les électrogrammes aux mécanismes se produisant au niveau du tissu cardiaque lors de la FA. Une analyse en temps réel permettrait de fournir au praticien des informations déterminantes lors de l'ablation concernant la nature et la localisation des sources d'arythmie
63

Stratégie d'alimentation pour les SoCs RF très faible consommation

Coulot, Thomas 15 October 2013 (has links) (PDF)
Les réseaux de capteurs sans fil nécessitent des fonctions de calcul et de transmissionradio associées à chaque capteur. Les SoCs RF intégrant ces fonctions doivent avoir uneautonomie la plus grande possible et donc une très faible consommation. Aujourd'hui, leursperformances énergétiques pourraient être fortement améliorées par des systèmes d'alimentationinnovants. En effet, les circuits d'alimentation remplissent leur fonction classique de conversiond'énergie mais aussi des fonctions d'isolation des blocs RF et digitaux. Leurs performancess'évaluent donc en termes d'efficacité énergétique et de réponse transitoire mais aussi d'isolationentre blocs et de réjection de bruit.Ce travail de thèse concerne l'intégration du système de gestion et de distribution del'énergie aux différents blocs RF d'un émetteur/récepteur en élaborant une méthodologie " topdown" pour déterminer la sensibilité de chaque bloc à son alimentation et en construisant unearchitecture innovante et dynamique de gestion/distribution de l'énergie sur le SoC. Cetteméthodologie repose sur la disponibilité de régulateurs de tension présentant des performancesadaptées. Un deuxième volet du travail de thèse a donc été de réaliser un régulateur linéaire detype LDO à forte réjection sur une bande passante relativement large et bien adapté àl'alimentation de blocs RF très sensibles aux bruits de l'alimentation.
64

Conception d’une tête radiofréquence auto adaptative au milieu de propagation pour les applications médicales

Chan wai po, Francis 23 July 2010 (has links)
L'impédance d'entrée d'une antenne miniature est fortement affectée par des facteurs environnementaux à l'origine de pertes de puissance réduisant l'efficacité énergétique des têtes radiofréquences dans les applications RF, en particulier dans la télémétrie des implants cardiaques. Le but de mes études est de développer une unité de calibration d'impédance d'antenne très faible consommation capable d'adapter toute variation de l'impédance d'entrée de l'antenne à l'impédance de la source radiofréquence. La première partie de mon étude est axée sur la conception au niveau système d'une approche nouvelle de calibration automatique du système. Un réseau d'adaptation automatique d'impédance sans coupleur et fonctionnant de façon directe est étudié et permet d'optimiser la taille du dispositif, la vitesse de l'adaptation, la consommation d'énergie et les performances globales. Deuxièmement, une nouvelle méthode de synthèse du réseau d'adaptation variable est proposée pour réduire fortement la complexité globale de l'algorithme d'adaptation. La troisième partie de mon étude est axée sur la fabrication d'un démonstrateur hybride fonctionnant dans la bande médicale MICS afin de valider le concept auto adaptatif d'impédance. Un banc expérimental qui comprend une antenne immergée dans son milieu connectée au démonstrateur piloté par un microcontrôleur a été mis en place et a permis d'atteindre un coefficient de réflexion jusqu'à -30dB avec un temps de calibration inférieur à 1ms. La dernière partie de mon travail consiste à concevoir le circuit d'adaptation automatique d'impédance d'antenne très faible consommation fonctionnant dans la bande ISM 2.4GHz en utilisant la technologie CMOS 0.13um. / Antenna input impedance is highly affected by environmental factors increasing the losses or reducing the power efficiency of the radiofrequency transceiver in many RF applications such as in implantable pacemaker device telemetry. The purpose of my study is to develop a low power fully integrated antenna-impedance tuning unit to match any variation of the antenna impedance to the source. The first part of my study is focused on the system-level design of a new approach to automatically match the system. A couplerless single step automatic matching network is investigated to optimize the die size, the speed, the power consumption and the overall performance. Second, a new method for synthesizing an automatic matching network is developed reducing strongly the overall complexity of the matching algorithm. The third part of my study is focused on the fabrication of a hybrid demonstrator operating at the Medical Implantable Communication Service (MICS) frequency band to validate the concept. An experimental set-up including the antenna tuning unit, a microcontroller and a pacemaker antenna connected to the demonstrator was done achieving a reflection coefficient up to -30dB, an overall tuning time less than 1ms. The last part of my work is to design the entire automatic matching network circuit in 0.13um CMOS technology including a front-end transceiver designed under ultra low power constraints and operating at 2.4GHz ISM frequency band. The additional items overall power consumption is less than 1.5mW under 1.2V supply voltage.
65

Contribution to the multi-physics study of porous media heated intermittently by RF energy in a coaxial cell / Contribution à l'étude multi-physique du chauffage de milieux poreux par énergie radiofréquence intermittente dans une cellule coaxiale

Wu, Li 17 December 2015 (has links)
Avec l'explosion économique et démographique, le besoin en matériaux poreux tels que la nourriture, le bois ou la brique connait une croissance telle que leur commerce est très actif dans le monde entier. La déshydratation des milieux poreux étant l'une des plus importantes et stables méthodes pour leur préservation, il est parfois nécessaire d'utiliser cette méthode pour stocker, transporter et mieux utiliser ces matériaux. Depuis la Seconde Guerre Mondiale, il existe des méthodes de chauffage RF dans bien des domaines. Bien que beaucoup de nouvelles technologies de chauffage sont devenues extrêmement importantes du point de vue commercial et très largement utilisées, le chauffage RF est préféré aux autres moyens de chauffage pour plusieurs raisons: 1) le résultat est plus rapide, nécessitant un moindre temps pour atteindre la température désirée; 2) le chauffage radiofréquence peut être spatialement plus uniforme que les méthodes conventionnelles de chauffage; 3) le chauffage par radiofréquences peut être allumé ou éteint instantanément; 4) il est plus efficace pour un grand volume de nourriture; 5) l'investissement nécessaire est moindre, etc. Cependant on trouve très peu d'information sur le chauffage radiofréquence pour la déshydratation des matériaux poreux dans la littérature. Par conséquent, il est intéressant d'étudier les interactions entre les radiofréquences et les milieux poreux. Afin d'améliorer le taux d'énergie radiofréquence utilisé, cette thèse propose une cavité coaxiale pour étudier le cycle de chauffage radiofréquence d'une pomme de terre dans différents états : solide, liquide et gazeux. Dans un premier temps nous avons étudié les mécanismes de transport de masse et de chaleur dans le milieu poreux sans radiofréquence sur le modèle d'une brique 1D à l'aide d'un code Matlab. Les résultats de simulation ont été comparés qualitativement avec ceux du papier de référence. A partir de ce modèle, nous avons construit et simulé un modèle 2D axisymétrique avec le chauffage radiofréquence périodique d'une pomme de terre. L’équation de Landau et Lifshitz, Looyenga a été utilisées pour prédire le changement de permittivité effective dans la simulation car il est difficile d'obtenir une donnée précise pour un milieu poreux. La salinité de l'échantillon chauffé (qui est une caractéristique très importante) a été estimée. Les effets de différentes périodes, hauteurs de l'échantillon et puissances de la distribution en température ont été étudiés et analysés. Nous avons également mené des expériences similaires pour mesurer les changements de température durant le processus de chauffage. Tous les résultats de simulations sont comparés qualitativement avec les résultats mesurés. De même nous avons effectué des analyses de sensibilité et en avons conclu quelques suggestions concernant l'amélioration des effets du chauffage. A partir de ces suggestions, nous avons proposé un nouveau modèle de chauffage radiofréquence afin de s'affranchir des défauts du modèle précédent. / With the rapid growth of economic and population explosion, the demands for porous media such as foods, woods and bricks enlarge so wildly that their trades are busy around the world. To be stored, transported and utilized better, dehydration of porous media is necessary since drying is one of the most important and stable methods for preserving materials. After World War two, possible RF heating in many domains was suggested. Even though a lot of novel heating technologies have become extremely commercially important and been widely used, RF heating is preferred to the other heating means for several significant reasons: 1) it is rapid and requires less time to come up to the desired process temperature; 2) radio frequency heating may be relatively spatially more uniform than conventional heating; 3) radio frequency heating systems can be turned on or off instantly; 4) it is better for large, thick food; 5) it requires lower investment costs, and so on. However, little information on radio frequency heating for commercial drying of porous media is available in the published literature. Therefore, it will be interesting to research the interaction between RF and porous media. This thesis, to improve the use ratio of RF energy further, proposed a coaxial cell to research RF cycling heating potato with different phases: solid, liquid and gas. The mechanism of mass and heat transport in the porous media without RF energy was studied first by solving the governing equations of 1D brick model with Matlab codes. The calculated results compared qualitatively with those in the reference paper. Based on that model, an axisymmetric 2D model with periodically RF heating potato was built and simulated. Landau and Lifshitz, Looyenga equation was employed to predict the effective permittivity change in the simulation since it is difficult to get the accurate measurement data of porous media. The salinity of heated sample- a very important parameter of the mixing rule-was estimated. The effects of different process period, variation of height of sample and power on the temperature distributions were studied and analyzed. Corresponding experiments were also conducted to measure the temperature change during the heating process. All the simulated results compared qualitatively with the measured ones. Sensitivity analysis was also done and some suggestions on the improvement of heating effect were concluded. Based on the suggestions, a new RF heating model was proposed to overcome the drawbacks of our previous model.
66

Automated assessment of cardiac morphology and function : An integrated B-spline framework for real-time segmentation and tracking of the left ventricle / Caractérisation automatique de la morphologie et de la fonction cardiaque : Une cadre B-spline intégré pour la segmentation et le suivi en temps réel du ventricule gauche

Barbosa, Daniel 28 October 2013 (has links)
L’objectif principal de cette thèse est le développement de techniques de segmentation et de suivi totalement automatisées du ventricule gauche (VG) en RT3DE. Du fait de la nature difficile et complexe des données RT3DE, l’application directe des algorithmes classiques de vision par ordinateur est le plus souvent impossible. Les solutions proposées ont donc été formalisées et implémentées de sorte à satisfaire les contraintes suivantes : elles doivent permettre une analyse complètement automatique (ou presque) et le temps de calcul nécessaire doit être faible afin de pouvoir fonctionner en temps réel pour une utilisation clinique optimale. Dans ce contexte, nous avons donc proposé un nouveau cadre ou les derniers développements en segmentation d’images par ensembles de niveaux peuvent être aisément intégrés, tout en évitant les temps de calcul importants associés à ce type d’algorithmes. La validation clinique de cette approche a été effectuée en deux temps. Tout d’abord, les performances des outils développés ont été évaluées dans un contexte global se focalisant sur l’utilisation en routine clinique. Dans un second temps, la précision de la position estimée du contour du ventricule gauche a été mesurée. Enfin, les méthodes proposées ont été intégrées dans une suite logicielle utilisée à des fins de recherche. Afin de permettre une utilisation quotidienne efficace, des solutions conviviales ont été proposées incluant notamment un outil interactif pour corriger la segmentation du VG. / The fundamental goal of the present thesis was the development of automatic strategies for left ventricular (LV) segmentation and tracking in RT3DE data. Given the challenging nature of RT3DE data, classical computer vision algorithms often face complications when applied to ultrasound. Furthermore, the proposed solutions were formalized and built to respect the following requirements: they should allow (nearly) fully automatic analysis and their computational burden should be low, thus enabling real-time processing for optimal online clinical use. With this in mind, we have proposed a novel segmentation framework where the latest developments in level-set-based image segmentation algorithms could be straightforwardly integrated, while avoiding the heavy computational burden often associated with level-set algorithms. Furthermore, a strong validation component was included in order to assess the performance of the proposed algorithms in realistic scenarios comprising clinical data. First, the performance of the developed tools was evaluated from a global perspective, focusing on its use in clinical daily practice. Secondly, also the spatial accuracy of the estimated left ventricular boundaries was assessed. As a final step, we aimed at the integration of the developed methods in an in-house developed software suite used for research purposes. This included user-friendly solutions for efficient daily use, namely user interactive tools to adjust the segmented left ventricular boundaries.
67

Contribution à l'amélioration de la sensibilité d'un micro-récepteur RMN implantable / contribution to the sensivity improvement of an implantable micro NMR sensor

Trejo Rosillo, Josue 28 November 2014 (has links)
Ce travail de thèse a pour objectif principal d'améliorer la sensibilité d'un micro-récepteur RMN implantable, utilisé dans le cadre de la micro-spectroscopie localisée in vivo. Dans la première partie de cette thèse, nous avons réexaminé la fabrication et modélisation de ce micro-récepteur par rapport à sa sensibilité. Parmi les deux procédés de fabrication proposés (électrodéposition du micro-récepteur avec un underpass sur un substrat de silicium et de verre), nous avons retenu celui-qui nous a permis d'obtenir les meilleures performances en termes de facteur de qualité. Les prototypes fabriqués avec ce procédé ont été caractérisés à l'aide d'un modèle que nous avons développé, basé sur une équation à coefficients polynomiaux. Ceux-ci ont été établis à partir de la simulation du layout du capteur et ont été réajustés en fonction des mesures. Ce modèle polynomial nous a conduits à un circuit équivalent du micro-récepteur, permettant d'approfondir l'étude de son comportement électrique en radio fréquences. La deuxième partie de ce travail est développée autour de l'association d'un amplificateur faible bruit (LNA) au plus près du micro-récepteur, afin d'améliorer sa sensibilité. Nous avons analysé l'état de l'art de l'amplification de micro-bobines RMN ainsi que l'interaction électromagnétique entre un circuit intégré et l'environnement RMN. En partant de cette analyse et des contraintes à remplir par le circuit d'adaptation (en termes de transmission de puissance, gain en tension et adaptation faible bruit), nous avons proposé un circuit d'amplification locale permettant d'améliorer la sensibilité du capteur. Nous avons validée notre démarche par simulation (avec notre micro-récepteur) et nous avons vérifié l'intérêt de celle-ci en RMN (avec une bobine de surface). Les résultats de ce travail nous ont permis d'établir des solutions concrètes pour atteindre la sensibilité nécessaire à nos applications / The aim of this thesis is to improve the sensitivity of an implantable micro NMR sensor, dedicated to the in vivo local micro-spectroscopy. In the first part of this thesis, we re-examined the design and modeling of this micro-sensor according to its sensitivity. We proposed two micromachining processes (electrodeposition of the micro-sensor with an underpass on a silicon and glass substrate) and we kept the one allowing the higher quality factor. The prototypes made with the chosen process were characterized thanks to a model that we developed, based in an equation with polynomial coefficients. These coefficients were determined from the layout of the sensor and were adapted to match the measurements. From this polynomial model, we proposed an equivalent circuit of the micro-sensor to have a better knowledge of its electrical behavior at high frequencies. The second part of this work is about the closer association of a low noise amplifier (LNA) with the micro-sensor to improve its sensitivity. We analyzed the state of art on the amplification of NMR micro-coils and the electromagnetic interaction between the integrated circuits ant the NMR environment. From this analysis and the conditions of the matching network (power transmission, voltage gain and low noise matching), we proposed a local amplification circuit achieving the sensitivity improvement of the sensor. This approach was validated by simulation (with our micro-sensor) and verified in an NMR system (with a surface coil). The results of this work allow us to set practical solutions to reach the required sensitivity of our applications
68

Back-propagation beamformer design with transverse oscillations for motion estimation in echocardiography / Formation de voie par rétro-propagation pour l'estimation du mouvement en échocardiographie

Guo, Xinxin 12 September 2014 (has links)
L'échographie est aujourd'hui l'une des modalités les plus populaires de diagnostic médical. Il permet d'observer, en temps réel, le mouvement des organes qui facilite le diagnostic des pathologies pour des médecins. L'échocardiographie [1, 2], l'imagerie du flux sanguin [3, 4] et l’élastographie [5-7] sont les domaines préférés de l'estimation de mouvement en utilisant l'échographie (en raison de son haut frame-rate).En conséquence, les images avec meilleurs qualités sont nécessaires. . En imagerie cardiaque, le système classique d'imagerie est limité dans la direction transversale (la direction perpendiculaire à celle de propagation). Travaillant sur la formation des images, ce problème peut être résolu en modifiant la façon de formateur de voie afin d'introduire des oscillations transversales (OTs) dans la fonction d’étalement du point (PSF). La technique d’oscillation transversale a montré son potentiel d'améliorer la précision de l'estimation de mouvement local dans la direction transversale (la direction perpendiculaire à celle de propagation). La classique OT en géométrie linéaire, basée sur l'approximation de Fraunhofer, relie la PSF et la fonction de pondération par la transformée de Fourier. Motivé par l'adaptation des OTs en échocardiographie, nous proposons une technique spécifique basée sur la rétro-propagation afin de construire des OTs en géométrie sectorielle. La performance de la méthode de rétro-propagation proposée a été étudiée progressivement, comparée avec la méthode de la transformée de Fourier, par exemple, l'évaluation de la qualité de la PSF quantifié, dans l'estimation de mouvement cardiaque en simulation, et en étude la qualité des PSF visuellement expérimentale. Les résultats quantifiés montrent les OT-images sont mieux contrôlés par la méthode proposée que par le formateur de voie conventionnelle. Une autre méthode, basée sur la décomposition d'onde plane et un principe différent de rétro-propagation, a été présentée. Cette méthode mieux prend en compte la propriété 2D de PSF, en décomposant la PSF dans un ensemble d'ondes planes directionnelle, les rétro-propage à la sonde, en utilisant les résultats de superposition comme excitations, un PSF simulée et conforme fortement au PSF théorique est acquis. En adaptant cette méthode à la géométrie sectorielle, la qualité de la PSF obtenue en face et sur la côté de la sonde est meilleure en utilisant la décomposition en ondes planes à celle de la transformée de Fourier, le travail supplémentaire sera adressé à adapter la décomposition en ondes planes à imagerie sectorielle et l’estimation du mouvement. / Echography is nowadays one of the most popular medical diagnosis modalities. It enables real-time observation the motion of moving organs which facilitates the diagnosis of pathologies for physician. Echocardiography [1, 2], blood flow imaging [3, 4] and elastography [5-7] are the favorite domains of motion estimation in using of echography (e.g., due to its high frame-rate capacity). Thus the requirements for imaging with high quality are on the primary place. In cardiac imaging, the conventional imaging system is somehow limited in the transverse direction (the direction perpendicular to the beam axis). Working on the image formation, this problem can be addressed by modifying the beamforming scheme in order to introduce transverse oscillations (TOs) in the system point spread function (PSF). Transverse oscillation techniques have shown their potential for improving the accuracy of local motion estimation in the transverse direction (i.e., the direction perpendicular to the beam axis). The conventional design of TOs in linear geometry, which is based on the Fraunhofer approximation, relates PSF and apodization function through a Fourier transform. Motivated by the adaptation of TOs in echocardiography, we propose a specific beamforming approach based on back-propagation in order to build TOs in sectorial geometry. The performance of the proposed back-propagation method has been studied gradually, in comparison with the Fourier transform, such as in evaluation of the quality of PSF, in estimation of simulated cardiac motion and in experiments study, etc. The quantified results demonstrate the proposed method leads to better controlled TOs images than the conventional beamforming. Another method based on plane wave decomposition and a different back-propagation principle has been presented. This method is better taking into account the 2D property of PSF, by decomposing the PSF into a set of plane waves directionally, back-propagating them to the probe, by using the superposition results as excitations, a simulated PSF with high accordance to the theoretical one is acquired. By adapting this method to sectorial geometry, the quality of PSF obtained in front of probe is better using the plane wave decomposition method than that of Fourier relation, but it is limited for the scanning on the side of probe, so the further work will be addressed to adapting the plane wave decomposition method to the complete sectorial imaging.
69

Exploitation des effets électro-optiques pour la sécurité en IRM : applications des liaisons optiques pour des capteurs RF endoluminaux et des sondes de mesure du TAS / Electro-optical effects for safety in MRI : optical methods for endoluminal RF coils and TAS measurement probes

Saniour, Isabelle 18 December 2017 (has links)
Le développement de systèmes IRM à plus haut champ magnétique statique s'est accompagné d'une interrogation légitime concernant l'effet des champs électromagnétiques RF sur les patients. L'effet peut être renforcé par l'introduction d'éléments conducteurs à l'intérieur de la bobine RF comme c'est le cas pour les capteurs endoluminaux utilisés pour l'analyse des parois digestives. Ces capteurs entraînent des risques d'échauffements locaux élevés pour le patient en raison du TAS local induit par le champ électrique RF en présence d'un fil conducteur. Ces capteurs ayant le potentiel de présenter un bénéfice pour le patient, il est nécessaire de s'affranchir de ces limitations. Le premier objectif de la thèse est le développement d'un capteur endoluminal à liaisons optiques. Un dispositif de découplage actif optique a été développé et caractérisé. Les images RMN in vitro montrent une distribution du RSB comparable au découplage classique, validant ainsi l'efficacité du découplage optique. Concernant la transmission optique du signal RMN, des travaux ont été réalisés afin de s'affranchir des contraintes liées à l'utilisation d'un guide d'onde pour la conversion électro-optique par effet Pockels. Le capteur a été rendu plus compact. En revanche, l'importance de contrôler le TAS local dans des conditions expérimentales données demeure un besoin ne s'arrêtant pas à ceux des capteurs endoluminaux. Le second objectif est donc la validation expérimentale d'une sonde électro-optique pour la mesure du champ électrique RF durant un examen IRM. Cette sonde a permis d'effectuer des mesures du champ électrique dans l'air et dans différents milieux biologiques à 3 T et 4,7 T et estimer le TAS local / The recent advancement in MRI systems and the increase of the static magnetic field strength were accompanied by a strong concern about the effect of RF electromagnetic fields on patients. The effect can be increased by the use of conductive elements inside the volume coil as in the case of endoluminal coils used to analyze digestive walls. These coils lead to an increase of the local SAR which is induced by RF electric field in the presence of the coaxial cable connecting the coil to the MR system, resulting in strong local heating. Giving that these coils have the potential to present a real benefit to the patient, it worth to overcome these limitations. Accordingly, the first objective of the thesis is the development of a fully optical endoluminal receiver coil. An optical active detuning system has been developed and characterized. The NMR images show a signal-to-noise ratio distribution similar to that obtained with conventional detuning techniques, thus validating the efficiency of the optical detuning. Concerning the electro-optical conversion and the optical transmission of the NMR signal, experiments were performed to overcome constraints related to the use of waveguide for electro-optical conversion by Pockels effect. Moreover, the importance of monitoring global and local SAR during MRI exams remains a need which is not limited only to the endoluminal coils. The second objective of the thesis is then the experimental validation of an electro-optical probe for real-time measurements of RF electric field. This probe can measure the RF electric field in air and in biological media at 3 T and 4.7 T MRI systems and allows the estimation of the local SAR
70

Planification de l’ablation radiofréquence des arythmies cardiaques en combinant modélisation et apprentissage automatique / Radiofrequency ablation planning for cardiac arrhythmia treatment using modeling and machine learning approaches

Cabrera Lozoya, Rocío 10 September 2015 (has links)
Les arythmies sont des perturbations du rythme cardiaque qui peuvent entrainer la mort subite et requièrent une meilleure compréhension pour planifier leur traitement. Dans cette thèse, nous intégrons des données structurelles et fonctionnelles à un maillage 3D tétraédrique biventriculaire. Le modèle biophysique simplifié de Mitchell-Schaeffer (MS) est utilisé pour étudier l’hétérogénéité des propriétés électrophysiologiques (EP) du tissu et leur rôle sur l’arythmogénèse. L’ablation par radiofréquence (ARF) en éliminant les activités ventriculaires anormales locales (LAVA) est un traitement potentiellement curatif pour la tachycardie ventriculaire, mais les études EP requises pour localiser les LAVA sont longues et invasives. Les LAVA se trouvent autour de cicatrices hétérogènes qui peuvent être imagées de façon non-invasive par IRM à rehaussement tardif. Nous utilisons des caractéristiques d’image dans un contexte d’apprentissage automatique avec des forêts aléatoires pour identifier des aires de tissu qui induisent des LAVA. Nous détaillons les sources d’erreur inhérentes aux données et leur intégration dans le processus d’apprentissage. Finalement, nous couplons le modèle MS avec des géométries du coeur spécifiques aux patients et nous modélisons le cathéter avec une approche par un dipôle pour générer des électrogrammes normaux et des LAVA aux endroits où ils ont été localisés en clinique. Cela améliore la prédiction de localisation du tissu induisant des LAVA obtenue par apprentissage sur l’image. Des cartes de confiance sont générées et peuvent être utilisées avant une ARF pour guider l’intervention. Les contributions de cette thèse ont conduit à des résultats et des preuves de concepts prometteurs. / Cardiac arrhythmias are heart rhythm disruptions which can lead to sudden cardiac death. They require a deeper understanding for appropriate treatment planning. In this thesis, we integrate personalized structural and functional data into a 3D tetrahedral mesh of the biventricular myocardium. Next, the Mitchell-Schaeffer (MS) simplified biophysical model is used to study the spatial heterogeneity of electrophysiological (EP) tissue properties and their role in arrhythmogenesis. Radiofrequency ablation (RFA) with the elimination of local abnormal ventricular activities (LAVA) has recently arisen as a potentially curative treatment for ventricular tachycardia but the EP studies required to locate LAVA are lengthy and invasive. LAVA are commonly found within the heterogeneous scar, which can be imaged non-invasively with 3D delayed enhanced magnetic resonance imaging (DE-MRI). We evaluate the use of advanced image features in a random forest machine learning framework to identify areas of LAVA-inducing tissue. Furthermore, we detail the dataset’s inherent error sources and their formal integration in the training process. Finally, we construct MRI-based structural patient-specific heart models and couple them with the MS model. We model a recording catheter using a dipole approach and generate distinct normal and LAVA-like electrograms at locations where they have been found in clinics. This enriches our predictions of the locations of LAVA-inducing tissue obtained through image-based learning. Confidence maps can be generated and analyzed prior to RFA to guide the intervention. These contributions have led to promising results and proofs of concepts.

Page generated in 0.4403 seconds