• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 329
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 348
  • 348
  • 193
  • 90
  • 76
  • 68
  • 55
  • 48
  • 45
  • 41
  • 30
  • 26
  • 25
  • 24
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Monitoramento de microcontaminantes orgânicos por métodos cromatográficos acoplados a espectrometria de massa e inorgânicos por fluorescência de pós-graduação em engenharia ambiental raios–x por reflexão total nas águas da Bacia do Rio Doce.

Quaresma, Amanda de Vasconcelos January 2014 (has links)
Programa de Pós-Graduação em Engenharia Ambiental. PROÁGUA, Pró-Reitoria de Pesquisa e Pós Graduação, Universidade Federal de Ouro Preto. / Submitted by Oliveira Flávia (flavia@sisbin.ufop.br) on 2015-03-03T17:47:35Z No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTACAO_MonitoramentoMicrocontaminantesOrgânicos.pdf: 11890984 bytes, checksum: c766515f3794668a9e2642feacdb2bba (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2015-03-10T13:56:12Z (GMT) No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTACAO_MonitoramentoMicrocontaminantesOrgânicos.pdf: 11890984 bytes, checksum: c766515f3794668a9e2642feacdb2bba (MD5) / Made available in DSpace on 2015-03-10T13:56:12Z (GMT). No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTACAO_MonitoramentoMicrocontaminantesOrgânicos.pdf: 11890984 bytes, checksum: c766515f3794668a9e2642feacdb2bba (MD5) Previous issue date: 2014 / Os microcontaminantes orgânicos de preocupação emergente, juntamente com os elementos inorgânicos, constituem atualmente o foco de muitos órgãos internacionais de proteção ao meio ambiente e à saúde humana e animal. Estes compostos, mesmo em pequenas concentrações no ambiente, são capazes de provocar efeitos adversos tanto no homem quanto na vida animal. A preocupação com estas substâncias no meio aquático aumenta cada vez mais, pois as rotas de contaminação são diversas e as tecnologias utilizadas comumente para o tratamento de águas e efluentes nao são eficazes para eliminá-los. Os microcontaminantes orgânicos e elementos inorgânicos apresentam características físico-químicas distintas, podem estar presentes em concentrações reduzidas em amostras complexas nos compartimentos ambientais. Estas características apresentam desafios no desenvolvimento de métodos analíticos para a determinação simultânea. Assim, esse trabalho focou no desenvolvimento de métodos analíticos para a determinação simultânea de microcontaminantes orgânicos e elementos inorgânicos em amostras de águas superficiais. Foram desenvolvidos e validados métodos para a determinação de 29 microcontaminantes de preocupação emergentes, os quais incluíram fármacos, plastificantes, hormônios naturais e sintéticos e subprodutos da degradação de detergentes usando cromatografia em fase líquida (UPLC) e em fase gasosa (GC) acopladas à espectrometria de massas (MS). Também foi desenvolvido e validado procedimento para a determinação de 13 elementos inorgânicos por fluorescência de raios – X por reflexão total (TXRF). Os procedimentos para a determinação de microcontaminantes orgânicos envolveram a pré-concentração e clean-up das amostras por extração em fase sólida (SPE), com recuperações variando entre 3,16 a 99,41 %. Os extratos produzidos foram divididos em frações para as análises por GC-MS e UPLC-HRMS. Para as análises por GCMS uma das frações foi derivatizada usando 75% BSTFA/25% piridina. Para os compostos orgânicos analisados por GC-MS foram obtidos limites de detecção do método que variaram de 0,50 a 6,97 ng/L e para os compostos analisados por UPLC-HRMS os limites foram de 0,58 a 7,44 ng/L. Para os elementos inorgânicos, os limites de detecção do método foram de 38,50 μg/L para K, 26,67 μg/L para Ca, 11,70 μg/L para Ti, 6,88 μg/L para Cr, 5,47 μg/L para Mn, 4,22 μg/L para Fe, 2,88 μg/L para Ni, 2,62 μg/L para Cu, 2,33 μg/L para Zn, 1,85 μg/L para As, 1,56 μg/L para Br, 2,15 μg/L para Sr, e 22,94 μg/L para o Ba. Os procedimentos validados foram aplicados para o monitoramento destas substâncias e elementos, ao longo da bacia do rio Doce (Minas Gerais, Brasil) em seis campanhas trimestrais nos anos de 2012 e 2013. Os elementos As, Cr e Ni foram encontrados em várias amostras. Dentre os microcontaminantes orgânicos monitorados o 4-octilfenol foi o mais encontrado nas amostras (91 %), seguido da cafeína (81 %), naproxeno (79 %), cimetidina (77 %) e atenolol (76 %). Os microcontaminantes orgânicos menos encontrados foram metformina (1,5 %), miconazol (1,5 %), aciclovir (2,2 %) e bezafibrato (2,2 %). Os resultados dessas análises foram tratados por meio da análise das componentes principais e foi possível observar o perfil de contaminação das amostras coletadas e relacioná-lo com dados da qualidade das águas nos locais de coleta. ______________________________________________________________________________________________ / ABSTRACT: The organic microcontaminants of emerging concern, as the inorganic elements, are currently the focus and concern of many international organitions for the protection of the environment and the health of humans and animals. Those compounds, even at small concentrations in the environment, are capable of causing adverse effects to human beings and biota. The concern with those substances in the aquatic environment increases everyday, because the routes of contamination are diverse and the technologies commonly used for treatment of wastewaters and waters are not efficient to eliminate them. The organic microcontaminants and inorganic elements present physical-chemical properties that are distinct, they can be present in lower concentrations in complex samples in the environmental compartments. Those characteristics present challenges in the development of analytical methods for their simultaneous determination. Therefore, this work was focused on the development of analytical methods for the simultaneous determination of organic microcontaminants and inorganic elements in surface water samples. Analytical methods using Ultra Performance Liquid Chromatography (UPLC) and Gas Chromatography (GC) coupled to the mass spectrometry (MS) for the determination of 29 organic microcontaminants of emergent concern were developed and validated. The compounds included pharmaceutical, plasticizers, detergent degradation by products, natural and synthetic hormones. A procedure for the determination of 13 inorganic elements by total reflection X-ray fluorescence (TXRF) was also developed and validated. The procedures for the determination of organic microcontaminants included the preconcentration and clean-up of the samples by solid phase extraction (SPE), with recoveries ranging from 3,16 to 99,41%. The extracts produced were divided in two fractions for GCMS and UPLC-HRMS analysis. For GC-MS analysis the fractions were derivatized using 75% BSTFA/25% pyridine. The methods limit of detection for the organic compounds analyzed by GC-MS varied from 0,50 to 6,97 ng/L; and for the compounds analyzed by UPLC-HRMS the limits of detection varied from 1,58 to 7,44 ng/L. The method limit of detection for inorganic elements analyzed by TXRF, were 38,50 μg/L for K, 26,67 μg/L for Ca, 17,33 μg/L for Ti, 6,88 μg/L for Cr, 5,47 μg/L for Mn, 4,22 μg/L for Fe, 2,88 μg/L for Ni, 2,62 μg/L for Cu, 2,33 μg/L for Zn, 1,85 μg/L for As, 1,56 μg/L for Br, 2,15 μg/L for Sr, and 22,94 μg/L for Ba. The validated procedures were applied to the monitoring of those substances, along the Rio Doce basin (Minas Gerais, Brazil), at six quarterly campaigns in the years of 2012 and 2013. The toxic elements As, Cr and Ni were found in some samples. Among the monitored organic microcontaminants, the 4-octylphenol was found in the majority of the samples (91%), followed by caffeine (81%), naproxen (79%), cimetidine (77%) and atenolol (76%). The less frequent organic microcontaminants were metformine (1,5%), miconazole (1,5 %) acyclovir (2,2%) and bezafibrate (2,2 %). The results of those analyses were treated by principal component analysis and it was possible to relate the observed contamination profile with water quality index data from the sampling points.
22

Caracterização de argamassas de barita como blindagens contra a radiação X e determinação experimental dos coeficientes de atenuação desses materiais.

Almeida Junior, Airton Tavares de January 2014 (has links)
Programa de Pós-Graduação em Engenharia de Materiais. Rede Temática em Engenharia de Materiais, Pró-Reitoria de Pesquisa e Pós-Graduação, Universidade Federal de Ouro Preto. / Submitted by Oliveira Flávia (flavia@sisbin.ufop.br) on 2015-10-16T20:26:15Z No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) TESE_CaracterizaçãoArgamassasBarita.pdf: 9621914 bytes, checksum: 4541c882bd6ca8bcd1a6e6772dddb620 (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2015-10-26T11:48:25Z (GMT) No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) TESE_CaracterizaçãoArgamassasBarita.pdf: 9621914 bytes, checksum: 4541c882bd6ca8bcd1a6e6772dddb620 (MD5) / Made available in DSpace on 2015-10-26T11:48:25Z (GMT). No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) TESE_CaracterizaçãoArgamassasBarita.pdf: 9621914 bytes, checksum: 4541c882bd6ca8bcd1a6e6772dddb620 (MD5) Previous issue date: 2014 / Os serviços de radiodiagnósticos, durante sua fase de construção, utilizam materiais de blindagens, afim de proteger o ambiente e as pessoas contra as radiações ionizantes. Dentre os materiais utilizados como barreiras protetoras, encontram-se o chumbo, o concreto e a barita. Porém, a argamassa de barita, material composto por cimento, areia, água e sulfato de bário, é a mais utilizada em virtude de apresentar algumas vantagens, tais como: alta eficiência como materiais atenuadores, aplicação de fácil manuseio, facilidade de ser encontrada no mercado nacional e baixo custo. No Brasil existem diversas ocorrências naturais de barita, sendo sua utilização, como blindagens, realizada independente do conhecimento de suas características de composição e poder de atenuação frente aos feixes de raios-X diagnósticos. Assim, com o intuito de conhecer suas propriedades, foram caracterizadas, neste trabalho, três tipos de argamassas de barita como materiais de blindagens contra a radiação X: a barita creme (densidade 2,99 g/cm3, proveniente do Estado de São Paulo), a barita roxa (densidade 2,95 g/cm3, proveniente do Estado da Bahia) e a barita branca (densidade 3,10 g/cm3, proveniente do Estado da Paraíba). As classificações mineralógicas das baritas estudadas foram obtidas utilizando um equipamento cicloclassificador e as análises químicas foram realizadas mediante o uso de um espectrômetro de fluorescência de raios X. Para determinar suas características de atenuação, as argamassas de barita foram confeccionados em placas quadradas, denominados corpos de prova, cujas dimensões foram (10 x 10) cm e espessuras variando aproximadamente entre 3 e 15 mm. O experimento foi realizado utilizando feixes de raios X padronizados segundo as qualidades de referência: RQR4, RQR6, RQR9 e RQR10, especificadas na norma IEC 61267. Os espectros incidentes e transmitidos através das placas foram determinados mediante a utilização de um sistema de espectrometria constituído por um detector CdTe. A partir dos espectros corrigidos, foram determinados os valores das camadas semirredutoras (CSR) e os coeficientes de atenuação linear de cada material para cada energia média dos feixes de raios X e obtidos, por meio de fatores de conversão, os espectros de kerma no ar (K), dose efetiva (E) e equivalente de dose ambiental (H*). __________________________________________________________________________ / ABSTRACT: This work addresses the characterization of barite mortars used as x-ray shielding materials through the following quantities: mass attenuation coefficient, air kerma, effective dose and ambient dose - H*(10). These shieldings were used in experimental measurements with the use of x-ray beams ranging from 60 to 150kV at the energy interval applied for radiodiagnostic. The semi reducer layers of the mortars were determined for each beam of radiation and mean energy at aforementioned energy interval of the incident spectra and transmitted to the mortars. The experiment was carried out with the use of the following reference qualities: RQR4, RQR6, RQR9 e RQR10, specified in accordance with norm IEC 61267: Medical diagnostic x-ray equipment – Radiation conditions for use in the determination of characteristics, (IEC, 2005). The values determined experimentally for the attenuation coefficient were compared with the theoretical data obtained through the WinXcom computer programmer through the use of the atomic composition of the shielding materials applied in this study. They were: Cream barite (density 2.99g/cm3, collected in the state of São Paulo), Purple barite (density 2.95g/cm3, collected in the state of Bahia) and White barite (density 3.10g/cm3, collected in the state of Paraiba). These materials, in the form of mortar, were disposed in the form of squares namely poof bodies, whose dimensions were 10 x 10 cm and thickness ranging from 3 to 15 mm approximately. These plates of barite had different compositions namely traces, which were obtained through the modification of the percentage of the components in the mixture (%cement, %sand, %water, %BaSO4). In the experimental procedure, these proof bodies were irradiated with a PANTAK, model HF320 industrial x-ray apparatus. The potentials applied to the respective X-ray tube were: 60kV, 80kV, 120kV and 150kV at a constant current of 1mA. The measurements of the spectra were carried out with the use of a system consisting of: a detector CdTe, a pre amplifier, an amplifier, a high voltage source, and a multi-channel analyzer. The mineral classifications of the materials studied were acquired through the cycle -classifier equipment. The chemical analysis was carried out by an x-ray fluorescence spectrometer model EDX-720, through dispersive energy. The attenuation responses in function of thickness, for each of the materials analyzed, were used to draw the attenuation and transmission curves. The efficiency of the barites studied concerning the capacity to attenuate x-ray radiation for x-ray beams ranging from 60 to 150 kV indicated satisfactory results when compared to the properties of lead as a shielding material.
23

Análise do 'LA''CR'O IND.3' dopado com 'SR' e 'CO',preparados via reação de combustão, utilizando difração de raios X com aplicação do método de Rietveld

Corrêa, Hamilton Perez Soares [UNESP] 06 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-06Bitstream added on 2014-06-13T19:02:32Z : No. of bitstreams: 1 correa_hps_dr_araiq.pdf: 1607395 bytes, checksum: f82fe479f8d076f190a34cd70dcb1714 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho, são apresentados os resultados da síntese, sinterização e caracterização dos óxidos de composição nominal La0,80Sr0,20Cr1-yCoyO3 (para y = 0,05; 0,08 e 0,10), obtidos via reação de combustão, utilizando nitratos como materiais de partida e uréia como combustível. Estes óxidos foram produzidos por pesquisadores do IPEN (Instituto de Pesquisas Energéticas e Nucleares), no CCTM (Centro de Ciência e Tecnologia de Materiais), para uso em células a combustível de óxidos sólidos (SOFC). Os produtos de síntese e sinterização são caracterizados estruturalmente utilizando difração de raios X (DRX) com aplicação do Método de Rietveld. Além disto, são feitas caracterização morfológica por MEV, medida de expansão térmica e de resistividade elétrica AC, por método da sonda quatro pontos (ou de quatro terminais). As propriedades apresentadas pelos materiais estudados são comparadas com as especificações exigidas para a aplicação como interconector em SOFC, o que significa: um material que permita a produção de corpos cerâmicos de alta densidade (acima de 95% de densificação), com coeficiente de expansão o mais próximo possível do valor de referência para as SOFC (10,5 OE 10-6 °C-1) e com boa propriedade de transporte de carga (condutividade eletrônica maior que 1,0 S.cm-1). As comparações mostraram que as composições contendo a dopagem com 5% e 8% de Co em mol apresentam potencial de uso promissor como interconector em SOFC. Palavras-chaves: difração de raios X; método de Rietveld; estrutura cristalina; cromito de lantânio; SOFC. / The results of the synthesis, sintering and characterization of oxides of nominal composition La0.80Sr0.20Cr1-yCoyO3 (with y = 0.05, 0.08 and 0.10), obtained via combustion synthesis, using nitrates as reagents and urea as fuel, are presented. The oxides were produced by researchers from IPEN (Instituto de Pesquisas Energéticas e Nucleares), at CCTM (Centro de Ciência e Tecnologia de Materiais), aiming at their use in solid oxide fuel cells (SOFC). The synthesis and sintering products are analyzed by means of X-ray diffraction (DRX) and the Rietveld Method. Further, morphological SEM (scanning electron microscopy) analysis, thermal expansion and AC electric resistivity, through the 4-point (or 4-terminal) method, are performed. The properties presented by the investigated materials are compared to the specifications needed to their use as interconnect component in SOFC, namely, a material which allows the production of high density ceramics (densification above 95%), with expansion coefficient as closest as possible to the reference value for SOFC (10.5 OE 10-6 °C-1) and good charge transport property (electric conductivity above 1.0 S.cm-1). The comparisons indicate that the compositions containing 5% and 8% of Co-doping in mol represent promising materials for use as interconnect component in SOFC. Keywords: X-ray diffraction; Rietveld method; crystal structure; lanthanum chromite; SOFC.
24

Síntese, caracterização e reatividade de complexos organoestânicos contendo bases de Schiff derivadas de aminoácidos com carbonilas de Mo. W e Re

Lima, Viner Sousa 07 August 2015 (has links)
Tese (doutorado)–Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-02-25T13:09:38Z No. of bitstreams: 1 2015_VinerSousaLima.pdf: 5403184 bytes, checksum: 532a39e9b5bb8d4affbf6c00dd2a9ff9 (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2016-05-26T18:11:41Z (GMT) No. of bitstreams: 1 2015_VinerSousaLima.pdf: 5403184 bytes, checksum: 532a39e9b5bb8d4affbf6c00dd2a9ff9 (MD5) / Made available in DSpace on 2016-05-26T18:11:41Z (GMT). No. of bitstreams: 1 2015_VinerSousaLima.pdf: 5403184 bytes, checksum: 532a39e9b5bb8d4affbf6c00dd2a9ff9 (MD5) / Neste trabalho retratamos a síntese e caracterização de complexos organoestânicos com bases de Schiff derivadas da condensação de aminoácidos com aldeídos e a reatividade destes complexos com carbonilas metálicas objetivando a formação de compostos heterobimetálicos do tipo [RxSn(BS)][M(CO)¬y], onde x = 1, 2, ou 3; BS = base de Schiff derivada de aminoácido; M = Mo, W, ou Re; y = 3, 4 ou 5. Foram utilizadas BSs já conhecidas e uma inédita na síntese dos complexos organoestânicos. Foram testados diversos precursores mono-, di- e triorganoestânicos e foram avaliadas diferentes possibilidades de rotas sintéticas de complexos com BSs, tendo sido obtidos cinco novos compostos puros e que puderam ser bem caracterizados, tanto em estado sólido quanto em solução, derivados do hexabutildiestanoxano, incluindo quatro estruturas resolvidas por difração de raios X em monocristal. A partir do dibutil(dimetóxi)estanano foi obtida uma estrutura por difração de raios X em monocristal de um novo complexo com BS, mas todos os produtos de reações com este precursor são extremamente instáveis à umidade e de difícil caracterização. Não foram isolados produtos puros com os precursores mono-organoestânicos. Foi demonstrada a eficiência da técnica de RMN para determinar a estrutura molecular dos compostos organoestânicos em solução utilizando parâmetros como deslocamento químico na RMN de 1H, 13C e 119Sn; valores de acoplamentos nJ(13C-119Sn); deslocamentos químicos na RMN de 15N em estado sólido versus solução; e HMBC 1H119Sn. As estruturas observadas em estado sólido para os derivados do hexabutildiestanoxano, com o átomo de SnIV pentacoordenado em uma geometria bipiramidal trigonal não são mantidas em solução; em CDCl3 os complexos obtidos existem com o SnIV também pentacoordenado, mas sem o carboxilato em ponte e com uma interação fraca com o nitrogênio imínico dos ligantes. Os estudos de reatividade dos complexos organoestânicos obtidos com carbonilas homolépticas de Mo e W indicam que não há reação, enquanto os estudos com derivados mais reativos [Bu4N][M(CO)5Br] e [M(MeCN)3(CO)3] levam à decomposição dos complexos organoestânicos e respectivos ligantes. Os estudos de reatividade com carbonilas de Re mostraram tendência ainda mais acentuada de decomposição em relação ao Mo e W, mesmo com a carbonila homoléptica de Re e ainda mais acentuada com seus derivados. _______________________________________________________________________________________ ABSTRACT / In this work we present the synthesis and characterization of organotin(IV) complexes with amino acid-derived Schiff bases and studies of reactivity of these complexes with metal carbonyls, aiming to obtain heterobimetallic compounds of general formula [RxSn(SB)][M(CO)-y], where x = 1, 2, or 3; SB = amino acid-derived Schiff base ligands; M = Mo, W, or Re; y = 3, 4 or 5. We studied eight Schiff bases already known and a novel one in the synthesis of the organotin(IV) complexes. Mono- di- and triorganotin(IV) precursors in different synthetic routes to obtain the Schiff base complexes were also studied, and five novel complexes from the precursor hexabutyldistannoxane were prepared in high yields and purity, being thoroughly characterized both in solution and solid state, including four structures resolved by single-crystal x-ray diffraction analysis. From dibutyl(dimethoxy)stannane, one structure was resolved by single-crystal x-ray diffraction, but all products from reactions with this precursor are highly moisture-sensitive and of difficult characterization. No pure products were isolated from the reactions with mono-iorganotin(IV) precursors. The efficiency of the NMR technique to elucidate organotin(IV) complexes structure in solution was widely demonstrated, and parameters such as 1H, 13C and 119Sn chemical shifts, nJ(13C-119Sn) coupling values, 15N NMR chemical shifts in solution and solid state, and 1H119Sn HMBC are discussed. Solid state structures, featuring a penta-coordinated tin(IV) atom in a trigonal bipyramidal geometry with three butyl groups in the equatorial positions and two oxygen atoms from the Schiff bases’ carboxylate occupying the apical positions, are not retained in solution; in CDCl3, the tin(IV) atom is also penta-coordinated, but the carboxylate bridging is lost and there is a interaction with the Schiff base’s imine nitrogen. Reactivity studies of the Schiff base organotin(IV) complexes with the homoleptic carbonyls of Mo and W led to no reaction at all, while reactivity studies with the more active species [Bu4N][M(CO)5Br] and [M(MeCN)3(CO)3] led to the decomposition of organotin(IV) complexes and respective ligands. Reactivity studies of the organotin(IV) complexes with rhenium carbonyls shown an even more severe proneness to decomposition, and organotin(IV) complexes and ligands decompose even with the relatively inert Re2(CO)10.
25

Técnicas de imagem para triagem de melanoma /

Panfilo, Beatriz Maria Lhanos. January 2012 (has links)
Orientador: Ana Gabriela Sávio / Coorientador: Vandereli Salvador Bagnato / Banca: José Dirceu Vollet Filho / Banca: Luciana Patricia Fernandes Abbade / Resumo: O câncer de pele é uma neoplasia que vem aumentando no Brasil e no mundo. Dentre eles está o melanoma, que embora represente apenas 4% dos cânceres de pele é responsável por 60% das mortes por esta neoplasia. Existem grandes dificuldades na triagem do melanoma, pois um de seus diagnósticos diferenciais é a queratose seborreica pigmentada. Tal fato causa grande dificuldade para o diagnóstico dos médicos não especialistas. O objetivo deste estudo foi identificar os padrões de autofluorescência de lesões de pele para que se possa excluir o diagnóstico de melanoma em lesões enegrecidas. Participaram 31 pacientes, com 31 lesões enegrecidas, sendo 17 pacientes com diagnóstico de melanoma e 14 pacientes com queratose seborreica pigmentada. Cada lesão enegrecida foi avaliada, sendo realizada foto macroscópica, dermatoscópica e fotos com fluorescência com o equipamento LINCE. Em seguida foi realizada biópsia de todas as lesões para confirmação diagnóstica. Foram avaliados os padrões de fluorescência da queratose seborreica e do melanoma. Através dos resultados observou-se que todas as lesões de queratose seborreica apresentaram um padrão de fluorescência peculiar. Quando iluminada pelo ultravioleta, a queratose seborreica apresentou estruturas puntiformes esbranquiçadas que permitiram diferenciá-la do melanoma. Tal diferença pôde ser vista em todas as lesões. Frente aos fatos apresentados no presente estudo, pode-se concluir que a fluorescência, pode excluir o diagnóstico de melanoma, facilitando a triagem de lesões enegrecidas / Abstract: Skin cancer, including melanoma, is increasing worldwide. Although melanoma represents only 4% of skin cancers it is responsible for 60% of deaths from this cancer. There are difficulties in screening for melanoma. One of the differential diagnosis is the pigmented seborrheic keratosis. The aim of this study was to identify patterns of fluorescence of skin lesions of sborreic keratosis to exclude the melanoma. It was taken 31 patients with 31 dark and assimetric lesions. Seventeen patients with melanomas lesions and 14 patients with pigmented seborrheic keratosis. Each lesion was evaluated, being held macroscopic and dermoscopic photo images with fluorescence by the prototipe named LINCE. Biopsies of all lesions were carried out for diagnostic confirmation. The fluorescence patterns of seborrheic keratosis and melanoma were evaluated. The results showed that all lesions of seborrheic keratosis showed a peculiar pattern of fluorescence. When illuminated by ultraviolet, all the seborrheic keratosis showed white dots that allowed differentiate it from melanoma. This difference was observed in all lesions. It can be concluded that fluorescence can exclude the diagnosis of melanoma when a pigmented lesion is evaluated / Mestre
26

Técnicas de imagem para triagem de melanoma

Panfilo, Beatriz Maria Lhanos [UNESP] 23 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-23Bitstream added on 2014-06-13T19:29:05Z : No. of bitstreams: 1 panfilo_bml_me_botfm.pdf: 670714 bytes, checksum: 9a685841adbac5afeb54be3702f287e2 (MD5) / Fundação Amaral Carvalho / O câncer de pele é uma neoplasia que vem aumentando no Brasil e no mundo. Dentre eles está o melanoma, que embora represente apenas 4% dos cânceres de pele é responsável por 60% das mortes por esta neoplasia. Existem grandes dificuldades na triagem do melanoma, pois um de seus diagnósticos diferenciais é a queratose seborreica pigmentada. Tal fato causa grande dificuldade para o diagnóstico dos médicos não especialistas. O objetivo deste estudo foi identificar os padrões de autofluorescência de lesões de pele para que se possa excluir o diagnóstico de melanoma em lesões enegrecidas. Participaram 31 pacientes, com 31 lesões enegrecidas, sendo 17 pacientes com diagnóstico de melanoma e 14 pacientes com queratose seborreica pigmentada. Cada lesão enegrecida foi avaliada, sendo realizada foto macroscópica, dermatoscópica e fotos com fluorescência com o equipamento LINCE. Em seguida foi realizada biópsia de todas as lesões para confirmação diagnóstica. Foram avaliados os padrões de fluorescência da queratose seborreica e do melanoma. Através dos resultados observou-se que todas as lesões de queratose seborreica apresentaram um padrão de fluorescência peculiar. Quando iluminada pelo ultravioleta, a queratose seborreica apresentou estruturas puntiformes esbranquiçadas que permitiram diferenciá-la do melanoma. Tal diferença pôde ser vista em todas as lesões. Frente aos fatos apresentados no presente estudo, pode-se concluir que a fluorescência, pode excluir o diagnóstico de melanoma, facilitando a triagem de lesões enegrecidas / Skin cancer, including melanoma, is increasing worldwide. Although melanoma represents only 4% of skin cancers it is responsible for 60% of deaths from this cancer. There are difficulties in screening for melanoma. One of the differential diagnosis is the pigmented seborrheic keratosis. The aim of this study was to identify patterns of fluorescence of skin lesions of sborreic keratosis to exclude the melanoma. It was taken 31 patients with 31 dark and assimetric lesions. Seventeen patients with melanomas lesions and 14 patients with pigmented seborrheic keratosis. Each lesion was evaluated, being held macroscopic and dermoscopic photo images with fluorescence by the prototipe named LINCE. Biopsies of all lesions were carried out for diagnostic confirmation. The fluorescence patterns of seborrheic keratosis and melanoma were evaluated. The results showed that all lesions of seborrheic keratosis showed a peculiar pattern of fluorescence. When illuminated by ultraviolet, all the seborrheic keratosis showed white dots that allowed differentiate it from melanoma. This difference was observed in all lesions. It can be concluded that fluorescence can exclude the diagnosis of melanoma when a pigmented lesion is evaluated
27

Relação entre o transporte elétrico e a estrutura de poros no sistema YBa2Cu3O7.

PIUMBINI, C. K. 29 January 2013 (has links)
Made available in DSpace on 2018-08-01T22:29:58Z (GMT). No. of bitstreams: 1 tese_6363_.pdf: 2628561 bytes, checksum: 3e3af9e30b8e2595b2b99caf767fe13e (MD5) Previous issue date: 2013-01-29 / Esta tese tem por objetivo o estudo da relação entre a densidade de corrente crítica de transporte e a estrutura de poros em amostras bulk do sistema YBa2Cu3O7-y. Para este fim, dois grupos de amostras foram preparados, um dopado com Sb2O3 e outro sintetizado em diferentes tempos. As amostras foram caracterizadas a partir de medidas de raios-X, magnetização, corrente critica de transporte e estudo da estrutura de poros via sorção de N2. Em ambos os sistemas, a dopagem e as condições de sínteses, não alteraram a temperatura crítica, porém modificaram a estrutura de poros. Com relação à densidade de corrente crítica de transporte, esse parâmetro não teve uma relação explicita com a porosidade no sistema (YBa2Cu3O7-y)1-x(Sb2O3)x, enquanto foi verificado uma forte correlação com a porosidade nas amostras sintetizadas em tempos diferentes. No intuito de melhor compreender a correlação entre densidade de corrente critica de transporte e as características estruturais das amostras, foram realizadas simulações computacionais visando descrever o transporte elétrico em sistemas cerâmicos supercondutores. Para este fim, a estrutura granular dos sistemas investigados foi simulada mediante a segmentação do espaço, utilizando o método Voronoi. Os resultados das simulações computacionais mostram que é possível capturar a dependência da densidade de corrente critica de transporte com as grandezas relevantes aos diferentes sistemas estudados nesta tese. Finalmente, esse trabalho mostra a importância de controlar a estrutura de poros, com o objetivo de otimizar as propriedades elétricas dos cupratos supercondutores cerâmicos, o qual é transcendente para possíveis aplicações tecnológicas destes sistemas.
28

Verificação das condições de uso e funcionamento dos aparelhos de raios X odontológicos, na cidade de Itajaí, Santa Catarina

Mezadri, Ariel César 12 May 2000 (has links)
Orientador: Frab Norberto Bóscolo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T06:54:43Z (GMT). No. of bitstreams: 1 Mezadri_ArielCesar_M.pdf: 13427930 bytes, checksum: 64f72909457587aefddb45598e8b7d12 (MD5) Previous issue date: 2000 / Resumo: Este foi um estudo realizado sobre as condições de uso e funcionamento em 70 aparelhos de raios X odontológicos, na cidade de Itajaí, Santa Catarina, com o objetivo de verificar se os profissionais estavam trabalhando dentro das normas preconizadas para o uso, e se os aparelhos estavam funcionando dentro dos padrões aceitáveis, fundamentado na Portaria n° 453, de 10 de junho de 1998, da Secretaria de Vigilância Sanitária do Ministério da Saúde. Foram analisados: tensão nominal da rede elétrica, reprodutibilidade e exatidão do tempo de exposição, tensão de pico, reprodutibilidade da taxa de Kerma no ar, linearidade da taxa de Kerma com o tempo de exposição, diâmetro e alinhamento de campo de radiação, determinação do tempo de exposição com escala de densidade, tipo e comprimento do localizador e padrão de imagem radiográfica. Os resultados obtidos indicaram que a quilovoltagem efetiva, no geral, foi menor que a nominal. Um percentual de 45,7% dos aparelhos precisavam correção imediata do tamanho de campo do feixe útil de radiação e 47,1% de alinhamento. Cerca de 14,3% dos pesquisados estavam utilizando localizadores do tipo cônico fechado. Dos profissionais, 78,6% não estavam seguindo corretamente as regras que norteiam o processamento de filmes fotográficos. Finalmente, conclui-se que os aparelhos de raios X avaliados não estavam trabalhando adequadamente dentro das normas peconizadas para seu uso. / Abstract: This work was a study accomplished on the use conditions and operation in 70 apparels of odontological X rays, in the city of Itajaí, Santa Catarina, with the objective of verifying if the professionals were using the recommended norms of handling and if the apparels were working inside of the acceptable patterns, being based in the judicial directive no. 453, of June 1, 1998, of the Clerkship of Sanitary Surveillance of the Ministry of the Health. They were analyzed: nominal tension of the electric net, reprodutability of the rate of Kerma in the air, linearity of the rate of Kerma with the time of exhibition, diameter and alignment of radiation field, determination of the time of exhibition with density scale, type and length of the finder and pattern of radiography image. The obtained results indicated that the effective quilovolt, in general, was smaller than to nominal. A percentile of 45,7% of the apparels needed immediate correction of the size of field of the useful bunch of radiation and 47,1% of alignment. About 14,30/0 of those researched were using finders of the shut conical type. Among professionals, 78,60/0 were not following correctly the rules of processing radiography. Finally, it was concluded that the apparels of X rays were not working according to the acceptable patterns, and the professional were not working appropriately inside the norms for X ray's use. / Mestrado / Mestre em Radiologia Odontológica
29

Estudo do composto CuGeO3 por técnicas espectroscópicas de fotoemissão e fotoabsorção de raios X

Zanchet, Daniela, 1972- 08 July 1996 (has links)
Orientador: Helio Cesar Nogueira Tolentino / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb-Wataghin / Made available in DSpace on 2018-07-22T09:07:18Z (GMT). No. of bitstreams: 1 Zanchet_Daniela_M.pdf: 2819486 bytes, checksum: 93a054e222c0c59c813710d173158f66 (MD5) Previous issue date: 1996 / Resumo: O composto CuGeO3 apresenta propriedades magnéticas interessantes. É um isolante, com cadeia linear antiferromagnética, que sofre transição de spin-Peierls em tomo de 14K. Utilizando técnicas espectroscópicas de fotoemissão (níve12p do cobre e banda de valência) e fotoabsorção de raios X, estudamos a estrutura eletrônica desse composto. Para explicar os espectros usamos o modelo de cluster, que considera processos de transferência de carga entre metal-ligante, interações eletrostáticas e um parâmetro de hibridização entre as configurações. O estado fundamental é uma mistura das configurações 3d9 e 3d10L (L denota uma buraco no ligante). O espectro do nível 2p apresenta um pico principal, que corresponde ao estado final c3d10L, e um satélite, em mais alta energia de ligação, correspondente ao estado c3d9 ( c denota um buraco no nível 2p do cobre). Em relação ao composto padrão CuO, o termo de hibridização é aproximadamente o mesmo já que as distâncias interatômicas são muito similares. Por sua vez, a transferência de carga entre cobre-oxigênio é dificultada devido à presença do germânio, que tende a estabilizar o sítio do oxigênio. O espectro da banda de valência também é composto por dois picos: um principal, formado por uma mistura dos estados 3d10L2 e 3d9L , e um pico satélite, em mais alta energia de ligação, de caráter predominante 3d8. Os efeitos da simetria e do campo cristalino são mais relevantes nesse caso e as simplificações do modelo limitam sua concordância quantitativa com os resultados experimentais. O espectro de fotoabsorção (borda K do oxigênio) pode ser interpretado qualitativamente como uma combinação dos espectros do CuO e do GeO2. O espectro apresenta um pico correspondente à hibridização Cu3d -O2p, e uma estrutura alargada em mais alta energia, correspondente à hibridização Ge4sp3/Cu4sp -O2p. A diminuição da intensidade do pico Cu3d -O2p em relação ao CuO é confirmada pela menor porcentagem da configuração 3d10L no estado fundamental, calculada pelo espectros de fotoemissão / Abstract: Not informed. / Mestrado / Física / Mestre em Física
30

Determinação de elementos traço em silacatos por espectrometria de fluorescencia de raios X : estudo e avaliação de metodologia

Toledo, Maria Auxiliadora Andrade 02 April 1998 (has links)
Orientador: Jacinta Enzweiler / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Geociencias / Made available in DSpace on 2018-07-23T16:28:06Z (GMT). No. of bitstreams: 1 Toledo_MariaAuxiliadoraAndrade_M.pdf: 2728604 bytes, checksum: 8ccfb0e128174d043cb2cd9d1462fc79 (MD5) Previous issue date: 1998 / Resumo: Esta dissertação trata da avaliação da qualidade dos dados obtidos na determinação de elementos traço em silicatos, por espectrometria de fluorescência de raios X. Os critérios utilizados nesta avaliação foram, precisão (instrumental e total), exatidão e limites de detecção. São apresentados os resultados da determinação de Ba, Ce, Cr, Cu, La, Nb, Ni, Pb, Rb, Sr, Th, V, Y, Zn e Zr, tendo sido todos analisados na forma de pastilhas prensadas. A precisão instrumental foi verificada utilizando repetidas determinações em uma mesma pastilha prensada do material de referência internacional WS-E. Os dados obtidos indicam boa precisão na determinação dos elementos Rb, Sr, Y, Zr, Nb, V e Zn com coeficientes de variação inferiores a 5%. Os elementos Pb, Ni e Cu apresentaram coeficientes entre 5 e 10%. Para Ba e Cr os dados obtidos indicam menor precisão com coeficientes 13 e 20%, respectivamente. A precisão instrumental representa a maior contribuição à precisão analítica total. Para avaliar a exatidão do método, os resultados obtidos para 21 materiais de referência internacionais foram comparados com os valores apresentados na literatura. Os elementos Nb, Rb, Sr, Y, Zn e Zr apresentaram diferenças relativas menores que 5%, em relação aos valores recomendados, para a maioria das determinações. Para Ni, Cr, V e Pb apresentam diferenças relativas superiores de 10% para a maioria das determinações foram obtidas. Os limites de detecção foram obtidos a partir da sensibilidade do instrumento para as condições analíticas empregadas. Os limites de detecção (6cr) variam de 2,5 ~g g-I (Y) a 43 ~g g-I (Ba) e tendem a ser superiores a limites de detecção apresentados na literatura. Foi preparado um material de referência interno, à partir de uma amostra de basalto. Para esse material além dos elementos traço, foram também determinados os elementos maiores. As análises foram feitas através de espectrometria de raios X e de absorção atômica. A amostra preparada também foi analisada num laboratório externo, havendo boa concordância entre os resultados dos dois laboratórios para a maior parte dos elementos. Os resultados obtidos foram avaliados utilizando-se critérios de controle de qualidade. A variabilidade dos resultados analíticos foi comparada com a precisão ideal, requerida para a utilização de dados analíticos em geoquímica pura. A comparação mostrou que o coeficiente de variação obtido na determinação de Nb, Rb, Sr, Y, Zn e Zr é satisfatório. Para os demais elementos uma precisão analítica menor foi obtida / Abstract: In this work, the quality of analytical data obtained by X-ray fluorescence spectrometry, for trace elements in silicates, was evaluated. Precision (instrumental and total), accuracy and detection limits were considered. Analytical programs were prepared for the determination of the following elements: Ba, Ce, Cr, Cu, La, Nb, Ni, Pb, Rb, Sr, Th, V, Y, Zn and Zr. Instrumental precision, obtained by replicate analysis ofthe same powder pellet of a reference material is better than 5% (RSD) for Rb, Sr, Y, Zr, Nb, V and Zn. Relative standard deviation for Pb, Ni and Cu was between 5 and 10%. Ba and Cr determinations had lower precision, with RSD of 13 and 20%, respectively. Instrumental precision was the main contribution to the total analytical precision. Accuracy was evaluated by analysis of 21 international reference materials and results were compared with recommended values. Relative differences lower than 5% were obtained for Nb, Rb, Sr, Y, Zn and Zr in most reference samples. Relative differences higher than 10% were obtained for Ni, Cr, Pb and V. Detection limits were evaluated considering sensitivities for the analytical conditions employed. Detection limits ( 6cr) were between 2.5 /-1g g-I (Y) and 43 /-1g g-J (Ba) and tended to higher values than those reported in the literature. A sample of basalt was prepared for use as an in house reference material. For this sample, beside the trace elements, also major elements were determined. Analysis were made using XRFand AAS. The same sample was also analyzed in an external laboratory, and good agreement between data of both laboratories was observed for the majority of elements. The results were evaluated considering quality control criteria. The variability of data was compared with the ideal precision required for use of analytical data in pure geochemistry. The comparison showed that the relative standard deviation for Nb, Rb, Sr, Y, Zn and Zr is satisfactory. For alI other elements evaluated in this study, lower analytical precision was obtained. / Mestrado / Metalogenese / Mestre em Metalogenese

Page generated in 0.0459 seconds