• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo dos efeitos do laser infravermelho sobre a retina fotocoagulada vias transescleral e transpupilar em coelhos / Experimental analysis of photocoagulated retina using transscleral and transpupillary infrared laser

Goulart, Dario Grechi 09 September 2008 (has links)
OBJETIVOS: A fotocoagulação retiniana transpupilar (FRP) tem seu uso, freqüentemente, limitado nos casos de opacidade acentuada dos meios oculares, situações nas quais pode-se empregá-la via transescleral. O presente estudo teve como objetivo realizar pesquisa experimental com o laser de diodo semicondutor infravermelho (LDI), a fim de estimar a reprodutibilidade, a segurança e a permeabilidade da parede ocular à sua atuação clínica (PPO), quando aplicado nesta técnica. MÉTODOS: Submeteram-se 18 olhos de 9 coelhos pigmentados, todos integrantes da raça Nova Zelândia (Oryctolagulos cuniculus), à fotocoagulação retiniana por LDI. No olho direito (OD) desses animais, realizou-se fotocoagulação via transescleral (FRT) sob parâmetros de potência e tempo pré-determinados clinicamente. No olho esquerdo (OE), foram repetidos os mesmos valores da potência e tempo usados no OD, mas, desta vez, sob uso da técnica da FRP. Passados 15 minutos das aplicações e após quatro semanas, estudos clínicos, baseados na retinografia, e histopatológicos foram realizados. RESULTADOS: Existe uma constante de PPO durante aplicação da FRT, cuja taxa varia de 58,95 a 63,87%. Observou-se que a média da PPO sob 300 mW (63,14%) é significativamente superior àquela encontrada sob 500 mW (59,11%), com significância de 5%. CONCLUSÕES: Este estudo sugere a existência da relação dose-resposta em relação aos parâmetros empregados na FRT, com PPO mensurável e boa reprodutibilidade clínica. Nenhuma rotura, hemorragia ou descolamento da retina (DR) foi constatado aos exames subseqüentes às aplicações do LDI, o que torna o uso do método viável e seguro no modelo experimental / PURPOSE: Recurrently retinal photocoagulation under poor visualization condition is often required. Transscleral delivery of infrared laser can be used as an alternative to standard transpupillary treatment. Based upon clinical aspects and retinographic measurements, we proposed to estimate reproducibility as well as ocular wall permeability rate for this treatment. Our primary goal was to evaluate whether this technique can deliver adequate photocoagulation at predetermined parameters. METHODS: In New Zealand pigmented rabbits, optimal transscleral infrared diode laser settings were administered to the right eye. With the same parameters, transpupillary photocoagulation was repeated to the left eye. Retinographic and clinical examinations were performed immediately and four weeks later. RESULTS: Ocular wall permeability rate varied between 58.95 and 63.87%. Average permeability using power of 300 mW (63.14%) was found to be higher than that encountered before its enhancement up to 500 mW (59.11%), (P < 0.05). CONCLUSIONS: Setting parameters showed dose-response effect. No retinal hole or retinal detachment was noticed in any rabbit. Transscleral infrared photocoagulation appeared to be a feasible, reproducible and secure method in the experimental model
2

Efeitos in vitro da radiação infravermelha longa em fibroblastos humanos oriundos do leito de feridas crônicas de etiologia venosa / In vitro effects of Far Infrared Radiation on human venous ulcer fibroblasts

Altran, Silvana Cereijido 12 February 2019 (has links)
Úlceras decorrentes de disfunções venosas são comuns na prática clínica. Fatores como hipóxia, infecção, acúmulo de fibroblastos senescentes, metabolismo anormal de colágeno e desequilíbrio entre produção e absorção de matriz extracelular contribuem para a cronicidade dessas lesões. Até o momento, não existe tratamento ideal para essas úlceras. A radiação infravermelha longa (FIR) tem sido proposta como opção. Diversos estudos descrevem efeitos antimicrobiano e anti-inflamatório, melhora na circulação sanguínea, regeneração de colágeno, aumento na proliferação de fibroblastos e expressão de TGF-beta, e aumento da síntese de óxido nítrico (NO), que tem papel importante em todas as fases da cicatrização. O objetivo deste estudo foi avaliar, por imunoensaios, a ação de substratos têxteis emissores de radiação infravermelha longa (FIR), em associação ou não à prata (FIR+Ag), sobre cultura de fibroblastos oriundos de úlcera venosa (venous ulcer fibroblasts VUFs) quanto a citotoxicidade, expressão de vimentina, colágeno dos tipos I e III, iNOS e VEGF, além do potencial antimicrobiano sobre cepas de bactérias frequentemente encontradas no leito de úlceras venosas. Ao que parece, o aditivo FIR sozinho, ou em combinação com prata, não exerceu efeito citotóxico sobre fibroblastos humanos (VUF). Houve aumento na expressão de vimentina em relação ao controle em todos os estímulos avaliados. Também foi observado aumento da expressão de iNOS estimulado pela prata. Não ocorreu aumento da expressão de VEGF e colágeno do tipo I e tipo do III. O efeito antimicrobiano de FIR foi comparável ao efeito classicamente descrito para a utilização de prata. Assim, acreditamos que o emprego de produtos têxteis emissores de FIR como curativos seja uma possível opção para o tratamento de úlceras venosas / Ulcers resulting from venous dysfunctions are common in clinical practice. Factors such as hypoxia, infection, accumulation of senescent fibroblasts, abnormal collagen metabolism and imbalance between production and absorption of extracellular matrix contribute to the chronicity of these sores. There is no ideal treatment for those ulcers. Far Infrared Radiation (FIR) has been proposed as a treatement option. Several studies describe antimicrobial and anti-inflammatory effects, improvement in blood circulation, regeneration of collagen, increased proliferation of skin fibroblasts, higher expression of TGF-beta and increased synthesis of nitric oxide (NO), which plays an important role in all phases of the wound healing process. The aim of this study was to evaluate the action of textile emitting FIR substrates, whether containing silver or not (FIR+Ag), on the culture of venous ulcer fibroblasts (VUFs) regarding to: cytotoxicity, vimentin, types I and III collagen, iNOS and VEGF expression as well as the antimicrobial potential on strains of bacteria frequently found in venous ulcers. Our results proved that FIR additives alone, or in combination with silver, did not exert a cytotoxic effect on human fibroblasts (VUF). There was an increase in vimentin expression in relation to the control in all evaluated stimuli. Increased stimulation of iNOS expression by silver was observed. No increase in the expression of VEGF and nor collagen types I and III was observed. An antimicrobial effect of FIR comparable to the effect classically described for the use of silver has been verified. Thus, we believe that the use of FIR-emitting textile products as curatives is a possible option for the treatment of venous ulcers
3

Estudo dos efeitos do laser infravermelho sobre a retina fotocoagulada vias transescleral e transpupilar em coelhos / Experimental analysis of photocoagulated retina using transscleral and transpupillary infrared laser

Dario Grechi Goulart 09 September 2008 (has links)
OBJETIVOS: A fotocoagulação retiniana transpupilar (FRP) tem seu uso, freqüentemente, limitado nos casos de opacidade acentuada dos meios oculares, situações nas quais pode-se empregá-la via transescleral. O presente estudo teve como objetivo realizar pesquisa experimental com o laser de diodo semicondutor infravermelho (LDI), a fim de estimar a reprodutibilidade, a segurança e a permeabilidade da parede ocular à sua atuação clínica (PPO), quando aplicado nesta técnica. MÉTODOS: Submeteram-se 18 olhos de 9 coelhos pigmentados, todos integrantes da raça Nova Zelândia (Oryctolagulos cuniculus), à fotocoagulação retiniana por LDI. No olho direito (OD) desses animais, realizou-se fotocoagulação via transescleral (FRT) sob parâmetros de potência e tempo pré-determinados clinicamente. No olho esquerdo (OE), foram repetidos os mesmos valores da potência e tempo usados no OD, mas, desta vez, sob uso da técnica da FRP. Passados 15 minutos das aplicações e após quatro semanas, estudos clínicos, baseados na retinografia, e histopatológicos foram realizados. RESULTADOS: Existe uma constante de PPO durante aplicação da FRT, cuja taxa varia de 58,95 a 63,87%. Observou-se que a média da PPO sob 300 mW (63,14%) é significativamente superior àquela encontrada sob 500 mW (59,11%), com significância de 5%. CONCLUSÕES: Este estudo sugere a existência da relação dose-resposta em relação aos parâmetros empregados na FRT, com PPO mensurável e boa reprodutibilidade clínica. Nenhuma rotura, hemorragia ou descolamento da retina (DR) foi constatado aos exames subseqüentes às aplicações do LDI, o que torna o uso do método viável e seguro no modelo experimental / PURPOSE: Recurrently retinal photocoagulation under poor visualization condition is often required. Transscleral delivery of infrared laser can be used as an alternative to standard transpupillary treatment. Based upon clinical aspects and retinographic measurements, we proposed to estimate reproducibility as well as ocular wall permeability rate for this treatment. Our primary goal was to evaluate whether this technique can deliver adequate photocoagulation at predetermined parameters. METHODS: In New Zealand pigmented rabbits, optimal transscleral infrared diode laser settings were administered to the right eye. With the same parameters, transpupillary photocoagulation was repeated to the left eye. Retinographic and clinical examinations were performed immediately and four weeks later. RESULTS: Ocular wall permeability rate varied between 58.95 and 63.87%. Average permeability using power of 300 mW (63.14%) was found to be higher than that encountered before its enhancement up to 500 mW (59.11%), (P < 0.05). CONCLUSIONS: Setting parameters showed dose-response effect. No retinal hole or retinal detachment was noticed in any rabbit. Transscleral infrared photocoagulation appeared to be a feasible, reproducible and secure method in the experimental model
4

Estudo da influência das redes locais sem-fio IEEE 802.11g na qualidade de voz estimada pelo modelo e / A Study of the influence of IEEE 802.11g wireless local networks on the voice quality estimated by the e-model

Marshall, Guilherme January 2006 (has links)
Este trabalho apresenta uma análise completa da qualidade de voz esperada em serviços de VoIP quando prestados sobre a plataforma WLAN IEEE 802.11g. Diferentemente da maior parte da literatura, este estudo complementa as informações de atraso, variação do atraso e taxa de perda dos pacotes, com um modelo analítico de avaliação de qualidade de voz proposto pela ITU-T, o Modelo E. Desta forma, todos os fatores modelados como perceptíveis pelos usuários do serviço telefônico são considerados simultaneamente, gerando, por fim, resultados correspondentes à escala de avaliação subjetiva da qualidade de voz MOS, que qualifica a opinião média em: “muito satisfeitos”, “satisfeitos”, “alguns insatisfeitos”, “muitos insatisfeitos”, “quase todos insatisfeitos” e “não recomendado”. O código do simulador NS-2 foi expandido para prover todas as funcionalidades requeridas neste trabalho. Com ele, diferentes cenários de aplicação foram simulados utilizando três dos codificadores de voz mais utilizados atualmente, o G.723.1, o G.729a e o G.711 (com e sem PLC). A funcionalidade centralizada da camada MAC IEEE 802.11, o PCF, também foi estudada, tendo os parâmetros referentes ao período entre repetições do CFP e à máxima duração do mesmo analisados e ajustados de modo a prover o melhor desempenho. Experimentos similares foram realizados para a função DCF, permitindo então uma comparação direta entre os dois modos de operação do nível MAC. Além disso, ensaios considerando outros tráfegos menos prioritários (estações de dados) foram realizados com o intuito de caracterizar a capacidade dos sistemas em diferenciar ambos os tráfegos. / This work is intended to provide a complete evaluation of the voice quality obtained in IEEE 802.11g WLAN environments. In contrast to the major literature, this dissertation complements the traditional network metrics, as delay, jitter and loss rate, with an analytical model for voice quality evaluation created by ITU-T, named E Model. With this model, all factors able of affecting the user’s perception of quality in a telephony service are simultaneously considered to reflect the subjective voice quality scale MOS, which rates the mean opinion as follow: “very satisfied”, “satisfied”, “some user satisfied”, “many users dissatisfied”, “nearly all user dissatisfied” and, “not recommended”. An extension to the NS-2 simulator source code has been developed to provide all the features required by this study. With this ‘customized simulator’, several scenarios have been analyzed considering three of the most important vocoders in the market today, G.723.1, G.729a, and G.711 (with and without PLC). Moreover, the centralized scheme for the IEEE 802.11 MAC, called PCF, has been studied to show the effect of the CFP repetition interval and the CFP maximum duration on its upper bound limit of simultaneous voice calls. Similar experiments have been carried out for the DCF MAC functionality, allowing these medium access modes to have their performance directly compared against each other. Finally, scenarios with low priority traffic (data traffic) have been created to help describing the ability of both MAC functions to deal with traffic differentiation.
5

Estudo da influência das redes locais sem-fio IEEE 802.11g na qualidade de voz estimada pelo modelo e / A Study of the influence of IEEE 802.11g wireless local networks on the voice quality estimated by the e-model

Marshall, Guilherme January 2006 (has links)
Este trabalho apresenta uma análise completa da qualidade de voz esperada em serviços de VoIP quando prestados sobre a plataforma WLAN IEEE 802.11g. Diferentemente da maior parte da literatura, este estudo complementa as informações de atraso, variação do atraso e taxa de perda dos pacotes, com um modelo analítico de avaliação de qualidade de voz proposto pela ITU-T, o Modelo E. Desta forma, todos os fatores modelados como perceptíveis pelos usuários do serviço telefônico são considerados simultaneamente, gerando, por fim, resultados correspondentes à escala de avaliação subjetiva da qualidade de voz MOS, que qualifica a opinião média em: “muito satisfeitos”, “satisfeitos”, “alguns insatisfeitos”, “muitos insatisfeitos”, “quase todos insatisfeitos” e “não recomendado”. O código do simulador NS-2 foi expandido para prover todas as funcionalidades requeridas neste trabalho. Com ele, diferentes cenários de aplicação foram simulados utilizando três dos codificadores de voz mais utilizados atualmente, o G.723.1, o G.729a e o G.711 (com e sem PLC). A funcionalidade centralizada da camada MAC IEEE 802.11, o PCF, também foi estudada, tendo os parâmetros referentes ao período entre repetições do CFP e à máxima duração do mesmo analisados e ajustados de modo a prover o melhor desempenho. Experimentos similares foram realizados para a função DCF, permitindo então uma comparação direta entre os dois modos de operação do nível MAC. Além disso, ensaios considerando outros tráfegos menos prioritários (estações de dados) foram realizados com o intuito de caracterizar a capacidade dos sistemas em diferenciar ambos os tráfegos. / This work is intended to provide a complete evaluation of the voice quality obtained in IEEE 802.11g WLAN environments. In contrast to the major literature, this dissertation complements the traditional network metrics, as delay, jitter and loss rate, with an analytical model for voice quality evaluation created by ITU-T, named E Model. With this model, all factors able of affecting the user’s perception of quality in a telephony service are simultaneously considered to reflect the subjective voice quality scale MOS, which rates the mean opinion as follow: “very satisfied”, “satisfied”, “some user satisfied”, “many users dissatisfied”, “nearly all user dissatisfied” and, “not recommended”. An extension to the NS-2 simulator source code has been developed to provide all the features required by this study. With this ‘customized simulator’, several scenarios have been analyzed considering three of the most important vocoders in the market today, G.723.1, G.729a, and G.711 (with and without PLC). Moreover, the centralized scheme for the IEEE 802.11 MAC, called PCF, has been studied to show the effect of the CFP repetition interval and the CFP maximum duration on its upper bound limit of simultaneous voice calls. Similar experiments have been carried out for the DCF MAC functionality, allowing these medium access modes to have their performance directly compared against each other. Finally, scenarios with low priority traffic (data traffic) have been created to help describing the ability of both MAC functions to deal with traffic differentiation.
6

Estudo da influência das redes locais sem-fio IEEE 802.11g na qualidade de voz estimada pelo modelo e / A Study of the influence of IEEE 802.11g wireless local networks on the voice quality estimated by the e-model

Marshall, Guilherme January 2006 (has links)
Este trabalho apresenta uma análise completa da qualidade de voz esperada em serviços de VoIP quando prestados sobre a plataforma WLAN IEEE 802.11g. Diferentemente da maior parte da literatura, este estudo complementa as informações de atraso, variação do atraso e taxa de perda dos pacotes, com um modelo analítico de avaliação de qualidade de voz proposto pela ITU-T, o Modelo E. Desta forma, todos os fatores modelados como perceptíveis pelos usuários do serviço telefônico são considerados simultaneamente, gerando, por fim, resultados correspondentes à escala de avaliação subjetiva da qualidade de voz MOS, que qualifica a opinião média em: “muito satisfeitos”, “satisfeitos”, “alguns insatisfeitos”, “muitos insatisfeitos”, “quase todos insatisfeitos” e “não recomendado”. O código do simulador NS-2 foi expandido para prover todas as funcionalidades requeridas neste trabalho. Com ele, diferentes cenários de aplicação foram simulados utilizando três dos codificadores de voz mais utilizados atualmente, o G.723.1, o G.729a e o G.711 (com e sem PLC). A funcionalidade centralizada da camada MAC IEEE 802.11, o PCF, também foi estudada, tendo os parâmetros referentes ao período entre repetições do CFP e à máxima duração do mesmo analisados e ajustados de modo a prover o melhor desempenho. Experimentos similares foram realizados para a função DCF, permitindo então uma comparação direta entre os dois modos de operação do nível MAC. Além disso, ensaios considerando outros tráfegos menos prioritários (estações de dados) foram realizados com o intuito de caracterizar a capacidade dos sistemas em diferenciar ambos os tráfegos. / This work is intended to provide a complete evaluation of the voice quality obtained in IEEE 802.11g WLAN environments. In contrast to the major literature, this dissertation complements the traditional network metrics, as delay, jitter and loss rate, with an analytical model for voice quality evaluation created by ITU-T, named E Model. With this model, all factors able of affecting the user’s perception of quality in a telephony service are simultaneously considered to reflect the subjective voice quality scale MOS, which rates the mean opinion as follow: “very satisfied”, “satisfied”, “some user satisfied”, “many users dissatisfied”, “nearly all user dissatisfied” and, “not recommended”. An extension to the NS-2 simulator source code has been developed to provide all the features required by this study. With this ‘customized simulator’, several scenarios have been analyzed considering three of the most important vocoders in the market today, G.723.1, G.729a, and G.711 (with and without PLC). Moreover, the centralized scheme for the IEEE 802.11 MAC, called PCF, has been studied to show the effect of the CFP repetition interval and the CFP maximum duration on its upper bound limit of simultaneous voice calls. Similar experiments have been carried out for the DCF MAC functionality, allowing these medium access modes to have their performance directly compared against each other. Finally, scenarios with low priority traffic (data traffic) have been created to help describing the ability of both MAC functions to deal with traffic differentiation.
7

Vasodilatação induzida pelo calor através de dispositivo portátil no leito na insuficiência cardíaca descompensada / Thermal vasodilation using a portable infrared thermal blanket in decompensated heart failure

Lima, Marcelo Villaça 24 March 2014 (has links)
Fundamento: medidas adjuvantes têm sido propostas para o tratamento de pacientes com insuficiência cardíaca, algumas não farmacológicas, como o uso do calor. Apesar dos resultados positivos para pacientes clinicamente estáveis, não existem trabalhos relacionados ao tratamento com calor na fase descompensada da insuficiência cardíaca em pacientes em uso de drogas vasoativas. Objetivos: avaliar os efeitos hemodinâmicos agudos do calor aplicado através da manta térmica em pacientes com insuficiência cardíaca descompensada (ICD) refratária. Para isso foi estabelecido como desfechos o aumento do índice cardíaco e a redução da resistência vascular sistêmica no primeiro dia de seguimento. Como objetivo secundário, avaliar se sessões repetidas de calor por cinco dias consecutivos promoveria ou sustentaria os efeitos hemodinâmicos obtidos agudamente e, se reduziria os níveis de BNP ao longo do seguimento. Métodos: ensaio clínico randomizado aberto, prospectivo, com grupo controle em pacientes portadores de ICD. O estudo foi dividido em duas fases. Na primeira fase foram estudados pacientes em um único dia e foi avaliado o efeito agudo do calor antes e após a intervenção. Na segunda fase o calor foi avaliado através de sessões diárias por cinco dias consecutivos. Foi utilizada a manta térmica por radiação infravermelha para o aquecimento dos pacientes. As medidas hemodinâmicas foram avaliadas por método invasivo através do cateter de Swan-Ganz e de maneira não invasiva pelo método de modelflow. Os pacientes estavam em uso de inotrópico endovenoso contínuo, no perfil hemodinâmico C segundo a classificação clínico-hemodinâmica de Stevenson e foram considerados refratários após tentativa de retirada da droga vasoativa sem sucesso. A população do estudo foi dividida em 2 grupos: grupo T (termoterapia) e grupo C (controle). O grupo T foi submetido à vasodilatação térmica através da manta térmica na temperatura de 50°C por 40 minutos adicionalmente ao tratamento medicamentoso. Os pacientes do grupo C mantiveram o tratamento medicamentoso e a manta térmica foi posicionada da mesma maneira por 40 minutos, porém desligada. Análise estatística: as variáveis foram analisadas pelo teste exato de Fisher ou razão de verossimilhança. A normalidade foi avaliada com o teste de Komogorov-Smirnov. As variáveis quantitativas foram apresentadas por média e desvio padrão. As médias foram avaliadas com análise de variância para medidas repetidas (ANOVA). Quando significante, utilizou-se contrastes para discriminar as diferenças entre os momentos. As medidas avaliadas em um único momento foram comparadas com teste t-Student. Foi utilizado o coeficiente de correlação de Pearson para a análise da correlação entre as medidas. Foram considerados estatisticamente significantes os valores de p < 0,05. Resultados: entre outubro de 2007 e abril de 2013, 165 pacientes foram avaliados para possível elegibilidade. Destes, 12 pacientes recusaram participar do estudo e 105 foram excluídos pelos critérios de exclusão. Foram incluídos 48 pacientes, entretanto, 10 pacientes foram excluídos prérandomização. Foram avaliados inicialmente 8 pacientes que foram submetidos a sessões de calor para segurança e validação do método e 30 pacientes foram randomizados até o término do estudo. No total, 38 pacientes foram estudados. Não houve diferença nas características basais entre os grupos estudados. Na primeira fase foram avaliados 38 pacientes, pré e pós-intervenção. A vasodilatação térmica foi capaz de aumentar o índice cardíaco em 24,1% e de reduzir a resistência vascular sistêmica em 16%. Na segunda fase os pacientes foram seguidos por 5 dias consecutivos conforme randomização e apresentaram melhora hemodinâmica significativa somente nos primeiros dois dias. O maior aumento do índice cardíaco foi de 23,3% e a maior redução da resistência vascular sistêmica foi de 19,3% no grupo tratado com calor. A partir do terceiro dia não houve mais benefício da termoterapia. Da mesma forma, não verificamos diferença entre os níveis de BNP dosados entre o primeiro e quinto dias de seguimento entre os grupos. Conclusões: o calor como vasodilatador foi capaz de aumentar o índice cardíaco e diminuir a resistência vascular sistêmica nos primeiros dias de tratamento na ICD. Entretanto, não houve benefício adicional em sessões repetidas por cinco dias consecutivos ou melhora dos níveis de BNP. Os dados sugerem que a termoterapia pode vir a representar uma abordagem terapêutica adjuvante para o tratamento dos pacientes com ICD. No entanto, um ensaio clínico randomizado com número maior de pacientes é necessário para explorar sua potencial efetividade clínica / Background: adjuvant measures have been proposed for the treatment of heart failure patients, some non-pharmacological, such as the use of heat. Despite the positive results for clinically stable patients, there are no studies related to use thermal therapy in patients with decompensated heart failure (DHF) and in use of vasoactive drugs. Objectives: To evaluate the acute hemodynamic effects of heat applied through the thermal blanket in patients with refractory decompensated heart failure. It was established as outcomes the increase of cardiac index and decrease of systemic vascular resistance on the first day of follow-up. Secondary objective was to evaluate whether repeated sessions of heat for five consecutive days would promote or sustain the hemodynamic effects obtained acutely, and if it would reduce BNP levels during the follow-up. Methods: open label randomized clinical trial, with control group, in patients with DHF. The study was divided into two phases. In the first phase, patients were studied in a single day and the acute effects of heat were evaluated before and after intervention. In the second phase, the effects of heat were evaluated by daily sessions for five consecutive days. An infrared thermal blanket was used to heating the patients. Hemodynamic measurements were assessed through invasive Swan-Ganz catheter and noninvasively by the method of modelflow. The patients were receiving continuous intravenous inotropic therapy and were classified in the profile C according to Stevenson´s clinical and hemodynamic classification and were considered refractory after failure in the attempted of withdraw the vasoactive drugs. The study population was divided into 2 groups: group T (thermal therapy) and group C (control). Group T was submitted to vasodilation through the thermal blanket at 50 °C for 40 minutes in addition to drug treatment. Patients in group C maintained the drug treatment and the thermal blanket was positioned in the same way for 40 minutes, but turned off. Statistical analysis: The variables were analyzed by Fisher\'s exact test or likelihood ratio. Normality was assessed with Komogorov-Smirnov test. Quantitative variables were presented as mean and standard deviation. Means were evaluated using analysis of variance for repeated measures (ANOVA). When significant, contrasts were used to discriminate the differences between times. Measurements evaluated at a single time were compared with Student\'s t test. We used the Pearson correlation coefficient to analyze the correlation between the measurements. A p-value < 0.05 was considered statistically significant. Results: Between October 2007 and April 2013, 165 patients were evaluated for possible eligibility. Of these, 12 patients refused to participate in the study and 105 were excluded by the exclusion criteria. There were included 48 patients, however, 10 patients were excluded in the pre-randomization. Eight patients were initially evaluated and were submitted to heart sessions for security and validation of the method and 30 patients were randomized until the end of the study. In total, 38 patients were studied. There were no differences in the baseline characteristics between the study groups. In the first phase, 38 patients were analyzed pre and post-intervention. The thermal vasodilation was able to increase the cardiac index by 24.1% and to reduce the systemic vascular resistance by 16%. In the second phase, patients were followed up for 5 consecutive days according to randomization and showed significant hemodynamic improvement only in the first two days. The largest increase in cardiac index was 23.3 % and the greatest reduction in systemic vascular resistance was 19.3 % in the group treated with heat. From the third day there was no benefit of thermal therapy. Likewise, there was no difference in the levels of BNP measured in the first and fifth day of follow-up between groups. Conclusions: heat as a vasodilator was able to increase the cardiac index and lower the systemic vascular resistance in the first days of treatment in the DHF. However, there was no additional benefit in repeated sessions for five consecutive days or improvement in the BNP levels. The data suggest that thermal therapy may come to represent a therapeutic approach for the adjuvant treatment of patients with DHF. Nonetheless, a randomized clinical trial with a larger number of patients is needed to explore its potential clinical effectiveness
8

Vasodilatação induzida pelo calor através de dispositivo portátil no leito na insuficiência cardíaca descompensada / Thermal vasodilation using a portable infrared thermal blanket in decompensated heart failure

Marcelo Villaça Lima 24 March 2014 (has links)
Fundamento: medidas adjuvantes têm sido propostas para o tratamento de pacientes com insuficiência cardíaca, algumas não farmacológicas, como o uso do calor. Apesar dos resultados positivos para pacientes clinicamente estáveis, não existem trabalhos relacionados ao tratamento com calor na fase descompensada da insuficiência cardíaca em pacientes em uso de drogas vasoativas. Objetivos: avaliar os efeitos hemodinâmicos agudos do calor aplicado através da manta térmica em pacientes com insuficiência cardíaca descompensada (ICD) refratária. Para isso foi estabelecido como desfechos o aumento do índice cardíaco e a redução da resistência vascular sistêmica no primeiro dia de seguimento. Como objetivo secundário, avaliar se sessões repetidas de calor por cinco dias consecutivos promoveria ou sustentaria os efeitos hemodinâmicos obtidos agudamente e, se reduziria os níveis de BNP ao longo do seguimento. Métodos: ensaio clínico randomizado aberto, prospectivo, com grupo controle em pacientes portadores de ICD. O estudo foi dividido em duas fases. Na primeira fase foram estudados pacientes em um único dia e foi avaliado o efeito agudo do calor antes e após a intervenção. Na segunda fase o calor foi avaliado através de sessões diárias por cinco dias consecutivos. Foi utilizada a manta térmica por radiação infravermelha para o aquecimento dos pacientes. As medidas hemodinâmicas foram avaliadas por método invasivo através do cateter de Swan-Ganz e de maneira não invasiva pelo método de modelflow. Os pacientes estavam em uso de inotrópico endovenoso contínuo, no perfil hemodinâmico C segundo a classificação clínico-hemodinâmica de Stevenson e foram considerados refratários após tentativa de retirada da droga vasoativa sem sucesso. A população do estudo foi dividida em 2 grupos: grupo T (termoterapia) e grupo C (controle). O grupo T foi submetido à vasodilatação térmica através da manta térmica na temperatura de 50°C por 40 minutos adicionalmente ao tratamento medicamentoso. Os pacientes do grupo C mantiveram o tratamento medicamentoso e a manta térmica foi posicionada da mesma maneira por 40 minutos, porém desligada. Análise estatística: as variáveis foram analisadas pelo teste exato de Fisher ou razão de verossimilhança. A normalidade foi avaliada com o teste de Komogorov-Smirnov. As variáveis quantitativas foram apresentadas por média e desvio padrão. As médias foram avaliadas com análise de variância para medidas repetidas (ANOVA). Quando significante, utilizou-se contrastes para discriminar as diferenças entre os momentos. As medidas avaliadas em um único momento foram comparadas com teste t-Student. Foi utilizado o coeficiente de correlação de Pearson para a análise da correlação entre as medidas. Foram considerados estatisticamente significantes os valores de p < 0,05. Resultados: entre outubro de 2007 e abril de 2013, 165 pacientes foram avaliados para possível elegibilidade. Destes, 12 pacientes recusaram participar do estudo e 105 foram excluídos pelos critérios de exclusão. Foram incluídos 48 pacientes, entretanto, 10 pacientes foram excluídos prérandomização. Foram avaliados inicialmente 8 pacientes que foram submetidos a sessões de calor para segurança e validação do método e 30 pacientes foram randomizados até o término do estudo. No total, 38 pacientes foram estudados. Não houve diferença nas características basais entre os grupos estudados. Na primeira fase foram avaliados 38 pacientes, pré e pós-intervenção. A vasodilatação térmica foi capaz de aumentar o índice cardíaco em 24,1% e de reduzir a resistência vascular sistêmica em 16%. Na segunda fase os pacientes foram seguidos por 5 dias consecutivos conforme randomização e apresentaram melhora hemodinâmica significativa somente nos primeiros dois dias. O maior aumento do índice cardíaco foi de 23,3% e a maior redução da resistência vascular sistêmica foi de 19,3% no grupo tratado com calor. A partir do terceiro dia não houve mais benefício da termoterapia. Da mesma forma, não verificamos diferença entre os níveis de BNP dosados entre o primeiro e quinto dias de seguimento entre os grupos. Conclusões: o calor como vasodilatador foi capaz de aumentar o índice cardíaco e diminuir a resistência vascular sistêmica nos primeiros dias de tratamento na ICD. Entretanto, não houve benefício adicional em sessões repetidas por cinco dias consecutivos ou melhora dos níveis de BNP. Os dados sugerem que a termoterapia pode vir a representar uma abordagem terapêutica adjuvante para o tratamento dos pacientes com ICD. No entanto, um ensaio clínico randomizado com número maior de pacientes é necessário para explorar sua potencial efetividade clínica / Background: adjuvant measures have been proposed for the treatment of heart failure patients, some non-pharmacological, such as the use of heat. Despite the positive results for clinically stable patients, there are no studies related to use thermal therapy in patients with decompensated heart failure (DHF) and in use of vasoactive drugs. Objectives: To evaluate the acute hemodynamic effects of heat applied through the thermal blanket in patients with refractory decompensated heart failure. It was established as outcomes the increase of cardiac index and decrease of systemic vascular resistance on the first day of follow-up. Secondary objective was to evaluate whether repeated sessions of heat for five consecutive days would promote or sustain the hemodynamic effects obtained acutely, and if it would reduce BNP levels during the follow-up. Methods: open label randomized clinical trial, with control group, in patients with DHF. The study was divided into two phases. In the first phase, patients were studied in a single day and the acute effects of heat were evaluated before and after intervention. In the second phase, the effects of heat were evaluated by daily sessions for five consecutive days. An infrared thermal blanket was used to heating the patients. Hemodynamic measurements were assessed through invasive Swan-Ganz catheter and noninvasively by the method of modelflow. The patients were receiving continuous intravenous inotropic therapy and were classified in the profile C according to Stevenson´s clinical and hemodynamic classification and were considered refractory after failure in the attempted of withdraw the vasoactive drugs. The study population was divided into 2 groups: group T (thermal therapy) and group C (control). Group T was submitted to vasodilation through the thermal blanket at 50 °C for 40 minutes in addition to drug treatment. Patients in group C maintained the drug treatment and the thermal blanket was positioned in the same way for 40 minutes, but turned off. Statistical analysis: The variables were analyzed by Fisher\'s exact test or likelihood ratio. Normality was assessed with Komogorov-Smirnov test. Quantitative variables were presented as mean and standard deviation. Means were evaluated using analysis of variance for repeated measures (ANOVA). When significant, contrasts were used to discriminate the differences between times. Measurements evaluated at a single time were compared with Student\'s t test. We used the Pearson correlation coefficient to analyze the correlation between the measurements. A p-value < 0.05 was considered statistically significant. Results: Between October 2007 and April 2013, 165 patients were evaluated for possible eligibility. Of these, 12 patients refused to participate in the study and 105 were excluded by the exclusion criteria. There were included 48 patients, however, 10 patients were excluded in the pre-randomization. Eight patients were initially evaluated and were submitted to heart sessions for security and validation of the method and 30 patients were randomized until the end of the study. In total, 38 patients were studied. There were no differences in the baseline characteristics between the study groups. In the first phase, 38 patients were analyzed pre and post-intervention. The thermal vasodilation was able to increase the cardiac index by 24.1% and to reduce the systemic vascular resistance by 16%. In the second phase, patients were followed up for 5 consecutive days according to randomization and showed significant hemodynamic improvement only in the first two days. The largest increase in cardiac index was 23.3 % and the greatest reduction in systemic vascular resistance was 19.3 % in the group treated with heat. From the third day there was no benefit of thermal therapy. Likewise, there was no difference in the levels of BNP measured in the first and fifth day of follow-up between groups. Conclusions: heat as a vasodilator was able to increase the cardiac index and lower the systemic vascular resistance in the first days of treatment in the DHF. However, there was no additional benefit in repeated sessions for five consecutive days or improvement in the BNP levels. The data suggest that thermal therapy may come to represent a therapeutic approach for the adjuvant treatment of patients with DHF. Nonetheless, a randomized clinical trial with a larger number of patients is needed to explore its potential clinical effectiveness

Page generated in 0.0452 seconds