• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 192
  • 1
  • Tagged with
  • 193
  • 193
  • 136
  • 114
  • 87
  • 80
  • 74
  • 71
  • 57
  • 50
  • 50
  • 48
  • 47
  • 45
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avalia??o in vitro das for?as geradas por cadeias el?sticas e molas fechadas de NiTi

Porto, Janise Bizarro Pereira 21 January 2010 (has links)
Made available in DSpace on 2015-04-14T13:29:39Z (GMT). No. of bitstreams: 1 424760.pdf: 9386318 bytes, checksum: 55f075ab7be050ba8f670a49a394022b (MD5) Previous issue date: 2010-01-21 / O objetivo do presente estudo foi avaliar, in vitro, as for?as produzidas pelas molas fechadas de n?quel-tit?nio de tr?s marcas comerciais diferentes (American Orthodontics?, TP orthodontics? e Morelli?) e cadeias el?sticas de duas marcas dispon?veis comercialmente (American Orthodontics? Memory Chain e Morelli? convencional) quando submetidas a distens?es de 50% e 100% do comprimento inicial e verificar o comportamento destas for?as ao longo do tempo. As for?as foram aferidas em cinco intervalos de tempo: inicial, 3, 4, 6 e 9 semanas. Para tanto 240 molas fechadas de n?quel-tit?nio e 80 segmentos de cadeias el?sticas foram divididos em 16 grupos de acordo com o tipo de material, mola fechada de n?queltit?nio ou cadeia el?stica, marca comercial e distens?o submetida. Para cada grupo 20 amostras foram distendidas em 50% ou 100% do comprimento inicial e assim mantidas em placas de a?o e imersas em solu??o de saliva artificial ? temperatura constante de 37?C. As for?as desenvolvidas pelas amostras foram aferidas atrav?s de um teste de tra??o realizado por uma m?quina de ensaio mec?nico Emic DL2000? ? velocidade de 0,5mm/minuto. Os resultados foram submetidos a testes estat?sticos ANOVA e Tukey. As molas fechadas de NiTi e cadeias el?sticas distendidas 50% do comprimento inicial apresentaram for?a inicial entre 126,3 e 267,5 gf e entre 192,6 e 267,8 gf, respectivamente; ao final de 9 semanas a m?dia de for?a ficou entre 131,7 e 263 gf para as molas fechadas e entre 123,7 e 141,3 gf para as cadeias el?sticas. Na distens?o de 100% do comprimento inicial a m?dia de for?a inicial apresentada pelas molas fechadas de NiTi ficou entre 214,3 e 451,5 gf e para as cadeias el?sticas entre 306,6 e 380,5 gf; ap?s 9 semanas a m?dia de for?a permaneceu entre 196,7 e 397,3 gf para as molas fechadas de NiTi e entre 179,4 e 189,3 gf para as cadeias el?sticas. Os resultados indicaram que tanto as molas fechadas de n?quel-tit?nio como as cadeias el?sticas desenvolveram for?as iniciais maiores e maior taxa de degrada??o da for?a ao longo do tempo quando distendidas 100% do comprimento inicial quando comparadas a distens?o de 50%. As molas fechadas de NiTi apresentaram menores percentuais de degrada??o da for?a do que as cadeias el?sticas nas duas distens?es avaliadas.
112

Resist?ncia de uni?o de cimentos resinosos auto-adesivos ? dentina

Tonial, Daniela 15 January 2009 (has links)
Made available in DSpace on 2015-04-14T13:29:43Z (GMT). No. of bitstreams: 1 411408.pdf: 3121916 bytes, checksum: d0e7791af851fbf98b39ad1f7dd9ed3f (MD5) Previous issue date: 2009-01-15 / O objetivo desse estudo foi avaliar, in vitro, a resist?ncia de uni?o ? microtra??o de cimentos resinosos auto-adesivos ? dentina, assim como a influ?ncia do pr?-tratamento com ?cido poliacr?lico nessa uni?o. Em terceiros molares humanos extra?dos foi obtida uma superf?cie oclusal plana em dentina, sendo a mesma regularizada com lixas de carbeto de sil?cio de granula??o 320, 400 e 600, respectivamente. Os dentes foram divididos aleatoriamente em cinco grupos: Grupo 1 RelyX ARC (controle); Grupo 2 RelyX Unicem; Grupo 3 Maxcem; Grupo 4 ?cido poliacr?lico 22,5% e RelyX Unicem; Grupo 5: ?cido poliacr?lico e Maxcem. Ap?s a aplica??o dos cimentos resinosos, foram constru?dos blocos de resina composta com 6 mm de altura. As amostras foram armazenadas em ?gua destilada a 37? C por 24 horas. Os conjuntos dente/resina foram cortados paralelamente ao longo eixo do dente, nos sentidos vest?bulo-lingual e m?sio-distal, com sec??o de aproximadamente 0,7 mm. Foram obtidos 20 corpos-de-prova para cada grupo, sendo ent?o submetidos ao teste de resist?ncia ? microtra??o em m?quina de ensaio universal com velocidade de 0,5 mm/min. As falhas foram observadas em microscopia eletr?nica de varredura. De acordo com a An?lise de Vari?ncia e o teste de Tukey (a=0,05), a maior m?dia de resist?ncia ? microtra??o foi para o RelyX ARC (21,38 MPa), n?o diferindo estatisticamente do Maxcem associado ao ?cido poliacr?lico (19,22 MPa) e RelyX Unicem associado ao ?cido poliacr?lico (17,75 MPa) (p>0,05). Estes dois ?ltimos grupos n?o diferiram estatisticamente do RelyX Unicem (16,98 MPa) (p>0,05). A menor m?dia foi obtida para o Maxcem (6,43 MPa), diferindo estatisticamente dos outros grupos (p<0,05). No grupo do Maxcem, sem pr?-tratamento com ?cido poliacr?lico, ocorreram somente falhas adesivas, e nos demais grupos as falhas foram predominantemente mistas.
113

Avalia??o da resist?ncia de uni?o entre infra-estrutura de zirc?nia e cer?mica de cobertura comparado com um sistema metalo-cer?mico

Carlucci, Cristiano Lages 18 March 2009 (has links)
Made available in DSpace on 2015-04-14T13:29:45Z (GMT). No. of bitstreams: 1 425713.pdf: 1781396 bytes, checksum: 7eeb594432bb477d3935d002b3c3bfbb (MD5) Previous issue date: 2009-03-18 / O objetivo deste estudo in vitro foi avaliar a resist?ncia de uni?o entre infraestrutura de zirc?nia e cer?mica de cobertura de um sistema livre de metal comparado com um sistema metalo-cer?mico. Para isso, foram confeccionados 40 blocos de zirc?nia (Procera Zirconia), onde 32 n?o possu?am cor e 8 possu?am cor A2) e 8 blocos met?licos (liga Viron 99), todos nas dimens?es (10 x 10 x 2 mm). As amostras de zirc?nia foram divididas em 5 grupos (8 em cada), e receberam diferentes tratamentos: Grupo 1 (zirc?nia s/ cor): aplica??o da dentina; Grupo 2 (zirc?nia c/ cor): aplica??o da dentina; Grupo 3 (zirc?nia s/ cor): aplica??o do liner + dentina; Grupo 4 (zirc?nia s/ cor): aplica??o do liner + dentina na superf?cie interna; Grupo 5 (zirc?nia s/ cor): desgaste com broca diamantada + liner + dentina. Como Grupo Controle: metalo-cer?mica (viron 99 + IPS Dsign dentina A2). Ap?s sinteriza??o das cer?micas de acordo com o fabricante, as amostras foram submetidas ao teste de resist?ncia ao cisalhamento realizados em m?quina de ensaios EMIC DL 2000, onde os resultados foram obtidos em MPa. Atrav?s de fotografias e de MEV com magnitude de 37X, 200X e 2000X foi verificado o tipo de falha que ocorreu na interface infra-estrutura e cer?mica de cobertura. Ao submeter os resultados ao teste ANOVA, foi poss?vel observar que houve diferen?as estatisticamente significantes entre os grupos (p=0,000). De acordo com teste de Tukey, o grupo controle obteve os maiores valores de resist?ncia de uni?o, estatisticamente diferente (p<0,05) aos demais grupos de zirc?nia. Os grupos de zirc?nia n?o apresentaram diferen?a estat?stica entre si (p>0,05). O grupo 2 apresentou a maior m?dia entre os grupos de zirc?nia e o grupo 4 apresentou a menor m?dia de todos os grupos testados. As falhas encontradas na interface foram 100% mistas em todas amostras e apenas 1 amostra do grupo 2 constatou-se falhas coesivas na infra-estrutura de zirc?nia. Concluiu-se que o grupo controle mostrou uma resist?ncia de uni?o aproximadamente 50% maior que todos os grupos de zirc?nia testados.
114

Influ?ncia de cimentos resinosos autoadesivos na deflex?o de c?spides e carga de fratura de pr?-molares restaurados com inlays em resina composta

Salaverry, Aur?lio 18 March 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:54Z (GMT). No. of bitstreams: 1 431091.pdf: 6484611 bytes, checksum: ee0b40e71498d6a5f8496211522ca10f (MD5) Previous issue date: 2011-03-18 / O objetivo desse estudo foi avaliar a influ?ncia de quatro cimentos resinosos (um convencional e tr?s autoadesivos) na deflex?o de c?spides, carga de fratura e tipos de fratura de pr?-molares com acesso endod?ntico e restaurados com inlays em resina composta. Setenta e dois primeiros pr?-molares foram divididos aleatoriamente em seis grupos (n=12): G1 (controle) - h?gidos; G2 cavidades sem restaura??o; G3 RelyX ARC; G4 RelyX U100; G5- Maxcem Elite; G6 SeT. Os Grupos 2-6 receberam preparos cavit?rios MOD e acesso endod?ntico. Os grupos 3-6 foram moldados com silicona por adi??o e vazados com gesso especial para confec??o de inlays em resina composta Z350 XT. As restaura??es indiretas foram cimentadas nas respectivas cavidades com carga de 1 Kg e fotoativadas. Ap?s armazenagem em ?gua destilada a 37? C por 72 horas, carga de 200 N foi aplicada na regi?o oclusal com uma esfera de 8 mm de di?metro acoplada na m?quina de ensaio universal EMIC DL 2000, sendo medida a deflex?o de c?spides com um micr?metro digital. Os corpos de prova foram ent?o submetidos a 500.000 ciclos de fadiga mec?nica, e novo teste de deflex?o de c?spides foi realizado. Em seguida, os corpos de prova foram submetidos ao ensaio de compress?o at? a fratura na m?quina de ensaio universal. De acordo com o teste de Kruskal-Wallis, a maior deflex?o de c?spides pr?-fadiga foi obtida para o grupo 2 (69 &#956;m), n?o diferindo estatisticamente do grupo 6 (51 &#956;m). As menores deflex?es de c?spides foram obtidas para o grupo 1 (4 &#956;m), o grupo 3 (4 &#956;m) e o grupo 4 (5 &#956;m), os quais n?o diferiram estatisticamente entre si. Valor intermedi?rio foi obtido para o grupo 5 (21 &#956;m), n?o diferindo estatisticamente dos grupos 3, 4 e 6. De acordo com o teste de Wilcoxon, n?o houve diferen?a estat?stica entre a deflex?o de c?spides pr? e p?s-fadiga apenas para o grupo 3 (p=0,015). De acordo com Kruskal-Wallis, a maior carga de fratura foi obtida para o grupo 1 (1902 N), diferindo estatisticamente dos outros grupos. Segundo maior valor foi obtido para o grupo 3 (980,8 N), diferindo estatisticamente dos outros grupos. Grupo 4 (670,6 N), grupo 5 (533,5 N), grupo 6 (601,3 N) e grupo 2 (526,6 N) n?o diferiram estatisticamente entre si. Para os grupos restaurados, houve predomin?ncia de fraturas recuper?veis. Inlays em resina composta cimentadas com RelyX ARC mantiveram a estabilidade da deflex?o de c?spides, proporcionaram maior recupera??o da resist?ncia da estrutura dent?ria, assim como fraturas mais favor?veis para a reabilita??o.
115

Correla??o entre absor??o de ?gua e tra??o diametral de dois cimentos resinosos ortod?nticos

Woitchunas, Carlos Alexandre 31 October 2011 (has links)
Made available in DSpace on 2015-04-14T13:30:04Z (GMT). No. of bitstreams: 1 435512.pdf: 973133 bytes, checksum: 14d9f2dc06508d0c9d2ae12d36de90f5 (MD5) Previous issue date: 2011-10-31 / Introduction: To determine whether a correlation between water absorption and diametral tensile strength (DTS) exists, two orthodontic adhesives - one of hydrophilic (Transbond Plus Color Change), and other of hydrophobic nature (Transbond XT) - were tested. Methods: Samples were divided into 4 groups (n = 10 each) according to the variables cement type and storage condition (Group I, XT dry; Group II, XT wet; Group III, Plus dry; and Group IV, Plus wet). After measuring and weighting, samples from groups I and III were kept dry, while those from groups II and IV were immersed in distilled water for 72 h. Then, all samples were stored at 37?C for 72 h, re-weighted and re-measured. Statistical analyses assessed significant differences among the groups. Results: Water absorption was significantly higher in group IV when compared to group II (p = 0.004). As for DTS, group IV values were significantly lower than those obtained from the other groups. A significant correlation between water absorption and diametrical tensile could not be demonstrated. Conclusion: Our results suggest that Transbond Plus Color Change samples, after immersion in distilled water, absorbs more water and has lower DTS values than those obtained from wet and dry Transbond XT samples. / Introdu??o: Este estudo foi conduzido com o objetivo de avaliar a correla??o entre absor??o de ?gua e tra??o diametral de dois cimentos resinosos, um com caracter?sticas hidrof?licas (Transbond Plus Color Change) e outro com caracter?sticas hidrof?bicas (Transbond XT). M?todos: Quarenta amostras divididas em 4 grupos (n=10), de acordo com as vari?veis tipo de cimento e meio de armazenagem (seco ou imerso em ?gua destilada). Grupo I (controle): XT seco. Grupo II: XT ?mido. Grupo III (controle): Plus seco. Grupo IV: Plus ?mido. As amostras dos grupos I e III, medidas e pesadas, foram mantidas secas. Os grupos II e IV imersos em ?gua destilada (100 ml) por 72 horas. Todas armazenadas em estufa (37oC, 72 horas), pesadas e medidas novamente. Para an?lise estat?stica foi utilizado o teste t de Student, an?lise de vari?ncia, teste de compara??es m?ltiplas de Tukey e an?lise de correla??o de Pearson. N?vel de signific?ncia m?ximo de 5% para todos os testes. Resultados: Para absor??o de ?gua o grupo IV apresentou valores significativamente superiores aos do grupo II (p=0,004). Para tra??o diametral o grupo IV apresenta valores significativamente inferiores aos outros grupos, seguido pelo grupo III. N?o houve correla??o significativa entre absor??o de ?gua e tra??o diametral. Conclus?o: Os resultados indicam que a Transbond Plus Color Change, ap?s imers?o em ?gua destilada, absorve mais ?gua e tem menor resist?ncia ? tra??o diametral do que Transbond XT imersa em ?gua destilada ou em ambiente seco.
116

Influ?ncia de diferentes cargas de cimenta??o na resist?ncia de uni?o de cimentos resinosos ? dentina

Paludo, Tamara 26 March 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:10Z (GMT). No. of bitstreams: 1 438178.pdf: 2149932 bytes, checksum: 72e349d1108a96e32586f332a6db74c4 (MD5) Previous issue date: 2012-03-26 / This study evaluated different loads during the cementation on the microtensile bond strength of conventional and self-adhesive resin cement. Fortytwo extracted caries-free molars were selected. Flat coronal dentin surfaces were exposed until the removal of enamel. The selected teeth were embedded in autopolymerized acrylic resin. Composite resin discs (Filtek Z 350 XT, 3M ESPE) were made according to the manufacturer?s instructions. Luting procedures with Rely X ARC - Group 1 (3M ESPE) were made with etched with 37% phosphoric acid gel, rinsed with water and the excess dentin moisture was removed and were applied two consecutive coats of the adhesive (Adper Single Bond 2) and light cured with halogen light (3M ESPE). Immediately the cement was manipulated according to the manufacturer s instructions and the composite discs were placed under 10N, 30N or 60N static load for 2 minutes. Specimens were light cured for a total of 160 seconds. Luting procedures with Rely X U100 (3M ESPE) - self-adhesive resin cement - Group 2 were made with moist dentin, the cement was manipulated according to the manufacturer s instructions, following the same protocol of the luting procedures of conventional resin cement. The bonded specimens were stored in water at 37?C for 24 hours. The restorations were embedded in autopolymerized acrylic resin and then longitudinally sectioned in the x and y directions perpendicular to the bonded interface to produce rectangular bonded sticks. Specimens (n=15) were divided according to cement and the load. The microtensile bond strength was conducted on a mechanical testing machine EMIC DL-2000. In order to evaluate the hybrid layer, two teeth of each group were cut perpendicular to the bonding interface, exposing the middle of the teeth. The surfaces were flatted and followed by polished and a dehydration process. Specimens were sputter coated with gold and examined with a scanning electron microscope (SEM) at a x1000 to a x4000 magnification. Data were subjected to Analysis of Variance and Tukey s test (p<0.05). The load of 30 N showed the best mean of the microtensile bond strength of the both groups (17,27 ? 5,33 MPa to group 1 and 15,33 ? 2,75 MPa to group 2). The load of 10 N of group 2 showed intermediary values (9,47 ? 4,07 MPa) followed by load of 10N (9,36 ? 5,08 MPa) and 60N of group 1 (7,84 ? 2,49 MPa). The load of 60N of group 2 resulted in the lowest values (7,34 ? 2,64 MPa). The mode of failure was determined using SEM and the mixed failure werer predominant in all groups. The results suggest that different load during the luting procedures can interfere on the bond strength of resin cements. / Este trabalho avaliou a influ?ncia de diferentes cargas de cimenta??o na resist?ncia de uni?o de cimento resinoso convencional e autoadesivo. Para isso, foram selecionados 42 molares humanos h?gidos. Os dentes foram desgastados em politriz at? a remo??o de esmalte. Os dentes tiveram suas ra?zes embutidas em resina acr?lica autopolimeriz?vel. Foram confeccionadas pastilhas de resina composta (Filtek Z 350 XT, 3M ESPE), conforme as orienta??es do fabricante. Para cimenta??o com cimento resinoso convencional Rely X ARC (3M ESPE) Grupo 1 foi realizado condicionamento ?cido da superf?cie (?cido fosf?rico 37%), lavagem, secagem com algod?o, aplica??o de duas camadas de adesivo (Adper Single Bond 2) e fotoativa??o atrav?s de um fotopolimerizador de luz hal?gena, seguido da manipula??o e da aplica??o do cimento, conforme orienta??es do fabricante. J? a cimenta??o com o cimento resinoso autoadesivo RelyX U100 (3M ESPE) Grupo 2 foi feita em dentina ?mida, manipula??o e aplica??o do cimento de acordo com orienta??es do fabricante. Em ambos os grupos, o bloco de resina composta foi posicionado sobre o cimento com carga de 10 N, 30 N e 60 N pelo tempo de dois minutos e fotoativado pelo tempo de 160 segundos (3M ESPE). As amostras foram armazenadas por 24 horas em 100% de umidade a 37?C. As restaura??es foram inclu?das com resina acr?lica autopolimeriz?vel e submetidas a cortes seriados, obtendo-se o formato de prismas. Os esp?cimes (n=15 para cada carga) ficaram divididos conforme o cimento e a carga utilizados. Ap?s, foram submetidos ao teste de resist?ncia de uni?o a microtra??o na m?quina de ensaios universal EMIC DL-2000. Al?m disso, dois conjuntos de cada grupo foram seccionados no sentido m?sio-distal, com um disco diamantado de dupla face. As superf?cies foram polidas com lixas de carbeto de sil?cio, seguido de polimento com pastas diamantadas. As amostras foram desmineralizadas, desproteinizadas, secadas, metalizadas e observadas em microsc?pio eletr?nico de varredura em aumento de 1.000 a 4.000 vezes. Os resultados foram submetidos ? An?lise de Vari?ncia e ao teste de Tukey HSD. A carga de 30N apresentou o maior valor de resist?ncia de uni?o em ambos os grupos, sendo 17,27 ? 5.33 MPa no Grupo 2 (dois) e 15,33 ? 2.75 MPa no Grupo 1 (um). J? a carga de 10 N apresentou valores intermedi?ri?rios de resist?ncia de uni?o, sendo (9,47 ? 4.07 MPa) para o Grupo 2 (dois) e (9,36 ? 5.08) para o Grupo 1 (um). A carga de 60 N foi a que apresentou menores valores de resist?ncia de uni?o (9,47 ? 2.64 MPa) para o Grupo 2 (dois) e (9,36 ? 2.49) para o Grupo 1 (um). Houve diferen?a estat?stica entre a carga de 30 N do Grupo 2 (dois) e a carga de 60 N do Grupo 1 (um) e tamb?m entre a carga de 30 N do Grupo 2(dois) com a carga de 60 N do Grupo 2 (dois). O tipo de fratura foi analisado atrav?s de imagens obtidas em MEV e a falha do tipo mista foi predominante em ambos os grupos e cargas. Os resultados sugerem que diferentes cargas de cimenta??o podem interferir na resist?ncia de uni?o do cimento resinoso RelyX ARC e Rely X U100.
117

Resist?ncia de uni?o ? dentina de um sistema adesivo de frasco ?nico : avalia??o em 24 horas e seis meses de armazenamento

Manfroi, Fernanda Borguetti 24 February 2014 (has links)
Made available in DSpace on 2015-04-14T13:30:34Z (GMT). No. of bitstreams: 1 459061.pdf: 2282963 bytes, checksum: c9b1fec421065d44d34540a0b1217b0a (MD5) Previous issue date: 2014-02-24 / The aim of this study was to evaluate the bond strength of Scotchbond Universal to dentin in both total-etch and self-etch applications after storage in water for 24 h and 6 months. The occlusal surface of 24 third molars was removed to obtain flat dentin surfaces, and the teeth were divided into four groups (n=6/grupo): G1 total-etch application of Scotchbond Universal; G2 self-etch application of Scotchbond Universal; G3 Scotchbond Multi Purpose (total-etch application control); G4 Clearfil SE Bond (self-etch application control). Following the adhesive application, a 6 mm height block of composite resin Z250 was built on the adhesive area. After storage in distilled water at 37?C for 24 hours, the tooth/resin sets were cut parallel to the long axis of the tooth, in the x and y directions, with a section of about 0.8 mm2. Forty specimens were obtained for each group; 20 specimens were immediately submitted to microtensile bond strength test, and the others after storage in distilled water at 37o C for 6 months. The microtensile bond strength test was performed in an universal testing machine (EMIC-DL 2000) at 0.5 mm/min crosshead speed. The failures were observed in scanning electron microscopy (SEM). Additionally, two sets of each group were sectioned mesio-distal in the center of their crown with a diamond blade. The surfaces were polished by wet sanding with 400, 600 and 1200-grit silicon carbide abrasive paper, followed by polishing with 6, 3, 1 and ? &#61549;m diamond paste. The samples were demineralized, deproteinized, dried, metalized and observed on a scanning electron microscope at 1.500x. The bond strength means (MPa) obtained were the following: 24 h G1 (39.37); G2 (31.02); G3 (35.09); G4 (35.84); 6 months G1 (36.99); G2 (40.58); G3 (32.44); G4 (41.75). According to two-way ANOVA, there was no significance for adhesive system (p=0,110) and storage time (0,108), but the interaction of adhesive system and storage time was significant (p=0.015). At 24 h, there was no statistical difference in bond strength between the adhesive systems (p>0,05). At 6 months, there was statistical difference between the adhesive systems (p<0.05). Clearfil SE Bond obtained the higher bond strength mean, not differing statistically from self-etch application of Scotchbond Universal. Total-etch application of Scotchbond Universal did not differ statistically from Scotchbond Multi Purpose. Most of failures were mixed in both periods of evaluation. The SEM images of the adhesive interface of Scotchbond Universal total-etch application and Scotchbond Multi Purpose showed thicker hybrid layers and more resin tags in comparison with Scotchbond Universal self-etch application and Clearfil SE Bond. It was concluded that the simplification of Scotchbond Universal in one bottle did not decrease the bond strength of this adhesive to dentin during 6 months of storage. / O objetivo do estudo foi avaliar a resist?ncia de uni?o ? dentina do sistema adesivo Scotchbond Universal na vers?o total-etch e self-etch em 24 horas e 6 meses de armazenamento. A superf?cie oclusal de 24 dentes terceiros molares h?gidos foi removida para obter superf?cie plana em dentina, sendo divididos aleatoriamente em quatro grupos (n=6/grupo): G1 - Scotchbond Universal na vers?o total-etch; G2 Scotchbond Universal na vers?o self-etch; G3 Scotchbond Multi Purpose (controle da vers?o total-etch); G4 Clearfil SE Bond (controle da vers?o self-etch). Sobre o sistema adesivo foi confeccionado um bloco de 6 mm de altura em resina composta Z250. Ap?s 24 horas de armazenagem em ?gua destilada a 37? C, os conjuntos dente/resina foram cortados paralelamente no longo eixo do dente, nos sentidos x e y, com sec??o de aproximadamente 0,8 mm2. Quarenta corpos de prova foram obtidos para cada grupo, sendo 20 submetidos imediatamente ao teste de resist?ncia ? microtra??o e, os outros 20, ap?s 6 meses de armazenamento em ?gua destilada a 37? C. O ensaio de microtra??o foi realizado em uma m?quina de ensaio universal EMIC DL-2000, com uma velocidade de 0,5 mm/min. Os tipos de falha foram observados em microscopia eletr?nica de varredura (MEV). Adicionalmente, dois conjuntos dente/resina foram preparados e seccionados no sentido m?sio-distal, no centro de suas coroas, com um disco diamantado de dupla face. As superf?cies foram polidas com lixas de carbeto de sil?cio 400, 600 e 1200, seguido de polimento com pastas diamantadas de granula??o 6, 3, 1 e ? &#61549;m. As amostras foram desmineralizadas, desproteinizadas, secadas, metalizadas e observadas em MEV em aumento de 1.500 vezes. No teste de microtra??o as m?dias obtidas (MPa) foram as seguintes: 24 h G1 (39,37); G2 (31,02); G3 (35,09); G4 (35,84); 6 meses G1 (36,99); G2 (40,58); G3 (32,44); G4 (41,75). De acordo com o teste ANOVA de duas vias n?o houve signific?ncia para o sistema adesivo (p=0,110) e para o tempo (0,108), mas apenas para a intera??o entre sistema adesivo e tempo (p=0,015). No per?odo de 24 horas, n?o houve diferen?a estat?stica significativa na resist?ncia ? microtra??o entre os sistemas adesivos (p>0,05). Na avalia??o de seis meses de armazenamento, houve diferen?a estat?stica entre os sistemas adesivos (p<0,05). O Clearfil SE Bond apresentou o maior valor m?dio de resist?ncia ? microtra??o, n?o diferindo estatisticamente do Scotchbond Universal self-etch e total-etch. O Scotchbond Universal total-etch n?o diferiu estatisticamente do Scotchbond Multi Purpose. Os tipos de falha foram predominantemente mistas para os dois per?odos de avalia??o. A interface adesiva do Scotchbond Universal na vers?o total-etch e o Scotchbond Multi Purpose apresentaram camada h?brida mais espessa e mais tags de resina em compara??o ao Scotchbond Universal na vers?o self-etch e Clearfil SE Bond. Concluiu-se que a simplifica??o em frasco ?nico do Scotchbond Universal n?o causou diminui??o nos valores de resist?ncia de uni?o deste material ? dentina em at? 6 meses de avalia??o.
118

Avalia??o da resist?ncia de uni?o das interfaces de cimenta??o de onlays em resina composta CAD/CAM

Souza, Ivana Agnoletto 29 February 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-06-29T19:51:31Z No. of bitstreams: 1 DIS_IVANA_AGNOLETTO_SOUZA_PARCIAL.pdf: 106952 bytes, checksum: 37ca419440e1901deef7a5328ff06ed2 (MD5) / Made available in DSpace on 2016-06-29T19:51:31Z (GMT). No. of bitstreams: 1 DIS_IVANA_AGNOLETTO_SOUZA_PARCIAL.pdf: 106952 bytes, checksum: 37ca419440e1901deef7a5328ff06ed2 (MD5) Previous issue date: 2016-02-29 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The aim of the study was to evaluate, in vitro, the weakest bond interface in Lava Ultimate onlays luted to the tooth preparation with Single Bond Universal and RelyX Ultimate. The following variables were tested: a) total-etch or the self-etch technique; b) with and without adhesive application on the internal surface of the onlay; c) with and without cyclic loading. Fifty-six Lava Ultimate onlays were milled and luted to the human tooth preparations according to the variables, being formed eight groups (n = 7): G1 and G2 - Single Bond Universal applied in the total-etch mode; G3 and G4 - Single Bond Universal applied in the self-etch mode; G5 and G6 - Single Bond Universal applied in the total-etch mode + adhesive application on the onlay; G7 and G8 - Single Bond Universal in the self-etch mode + adhesive application on the onlay. The onlays were luted with RelyX Ultimate. After storage in distilled water at 37? C for 24 h, only the samples from G2, G4, G6 and G8 were submitted to cyclic loading at 100 N using 1000,000 cycles. Beams with a cross section area of ~0.80 mm2 from all groups were obtained and submitted to a microtensile bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. The types of failure were observed in optical microscope. The microtensile bond strength values were analyzed by three-way ANOVA and post-hoc multiple comparison using Tukey?s test (?=0.05). There was a significant interaction between the three factors (p = 0.006).The means followed by the same letter represent no statistical difference for the microtensile bond strength (MPa): G6 = 34.64 (?34.64)a, G1 = 34.48 (?12.58)a, G2 = 31.94 (?9.18) ab, G5 = 30.88 (?6.85)abc, G7 = 26.66 (?8.25)bc, G8 = 24.03 (?7.65)cd, G4 = 18.81 (?4.14)de, G3 = 14.64 (?5.35)e. Most failures were at the resinous agent-restoration interface. It was concluded that the resinous agent-restoration interface corresponds to the weakest interface in Lava Ultimate onlays luted with Single Bond Universal and RelyX Ultimate. The application of Single Bond Universal on the internal surface of the onlay was not a relevant procedure. / Este estudo teve como objetivo avaliar, in vitro, a interface de uni?o menos resistente de onlays em resina composta Lava Ultimate cimentadas ao preparo dent?rio com Single Bond Universal e RelyX Ultimate, nas seguintes vari?veis: a) aplica??o do sistema adesivo no modo total-etch e self-etch; b) com e sem aplica??o do adesivo na superf?cie interna da onlay; c) sem e com ciclagem mec?nica. Ao total foram fresadas 56 onlays em resina composta Lava Ultimate, sendo cimentadas aos preparos em dentes humanos de acordo com as vari?veis empregadas, sendo formados oito grupos (n=7): G1 e G2 - Single Bond Universal na vers?o total-etch; G3 e G4 - Single Bond Universal na vers?o self-etch; G5 e G6 - Single Bond Universal na vers?o total-etch + adesivo na onlay; G7 e G8 - Single Bond Universal na vers?o self-etch + adesivo na onlay. As onlays foram cimentadas com o cimento resinoso RelyX Ultimate. Ap?s armazenamento em ?gua destilada a 37? C por 24 h, apenas as amostras do G2, G4, G6 e G8 foram submetidas ? ciclagem mec?nica com carga vertical de 100 N na superf?cie oclusal das coroas, totalizando 1.000.000 de ciclos. Todas as restaura??es, de todos os grupos, foram seccionadas nos eixos x e y para obten??o de corpos de prova em forma de palitos, com aproximadamente 0,80 mm2 de sec??o transversal. Os corpos de prova foram submetidos ao teste de microtra??o na m?quina de ensaio universal EMIC-DL 2000 com velocidade de 0,5 mm/minuto. Os tipos de falha foram observados em microsc?pio ?ptico. Os valores de resist?ncia ? microtra??o foram analisados pela ANOVA de tr?s vias, seguido do teste de Tukey ao n?vel de signific?ncia de 5%. Houve intera??o significativa entre os tr?s fatores (p=0,006). As m?dias seguidas de mesma letra n?o diferem estatisticamente para a resist?ncia ? microtra??o (MPa): G6 = 34,64 (?34,64)a, G1 = 34,48 (?12,58)a, G2 = 31,94 (?9,18) ab, G5 = 30,88 (?6,85)abc, G7 = 26,66 (?8,25)bc, G8 = 24,03 (?7,65)cd, G4 = 18,81 (?4,14)de, G3 = 14,64 (?5,35)e. A maioria das falhas foram na interface agente resinoso-restaura??o. Conclui-se que a interface agente resinoso/restaura??o corresponde ? interface menos resistente na cimenta??o de onlays em resina composta Lava Ultimate quando empregado o sistema adesivo Single Bond Universal e o cimento resinoso RelyX Ultimate. A aplica??o do adesivo Single Bond Universal na superf?cie interna da restaura??o n?o se mostrou um procedimento relevante.
119

Uni?o de materiais adesivos ? cer?mica e ao pol?mero

Silva, Diego Fabris Ferreira da 29 April 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-08-04T16:52:19Z No. of bitstreams: 1 TES_DIEGO_FABRIS_FERREIRA_DA_SILVA_PARCIAL.pdf: 375820 bytes, checksum: 360a10d42cd00d37ac088a725357896a (MD5) / Made available in DSpace on 2016-08-04T16:52:19Z (GMT). No. of bitstreams: 1 TES_DIEGO_FABRIS_FERREIRA_DA_SILVA_PARCIAL.pdf: 375820 bytes, checksum: 360a10d42cd00d37ac088a725357896a (MD5) Previous issue date: 2016-04-29 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The aim of the study was to evaluate the bond strength of Single Bond Universal adhesive and Adper Scothbond Multi-Purpose adhesive, with and without application of silane, on the feldsphatic ceramic and composite resin. It was always evaluated the bond strength of zirconia primers and a universal adhesive to zirconia ceramic. Sixty feldspathic ceramic samples, 60 composite resin samples and 76 zirconia ceramic samples were embedded in acrylic resin, followed by polishing with 600 and 1200 grit silicon carbide abrasive paper. The ceramic surface was etched with 10% hydrofluoric acid, and the composite resin and zirconia surface were sandblasted with 50 ?m aluminum oxide. The feldspathic and composite resin samples were divided into four groups (n=15) for each material: G1 ? Adper Scothbond Multi-Purpose adhesive (SBMP); G2 ? Silane + SBMP; G3 ? Single Bond Universal (SBU); G4 ? silane + SBU. The zirconia samples were divided into five groups (n=15): G1 ? Single Bond Universal (SBU); G2 ? silane + SBU; G3 - Signum Zirconia Bond; G4 - Z-Prime Plus; G5 - MZ Primer. A cone of composite resin was built on the applied adhesives. The specimens were stored in relative humidity of 100% at 37oC for 48 h, and then submitted to tensile bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. The type of failures was analyzed. The results obtained with feldspathic ceramic and composite resin were submitted to Kruskal-Wallis and Mann-Whitney test (?=0,05). Values of bond strength (MPa) followed by different letters are statistically different: Ceramic: G2=21.23a, G4=8.87b, G3=3.24c, G1=2.73c. Composite resin: G2=24.59a, G3=20.91ab, G4=19.77bc, G1=17.00c. The adhesive failures were predominant for ceramic and composite resin, except groups 2 and 4 of the ceramic. The results obtained with zirconia ceramic were analyzed using ANOVA and Tukey?s test (?=0.05). Mean values of bond strength (MPa) followed by different letters are statistically different: Ceramic: G2=27.55a, G4=23.71a, G1=22.64a,G5=13.64b, G3=7.54c. The failures were predominantly cohesive in composite resin cone in groups 1, 2 and 4. The failures were predominantly mixed in group 5, and all failures were adhesive in group 3. The application of silane prior to the adhesives provided greater bond strength with feldspathic ceramic. For the composite resin, the prior application of silane was important for SBMP and not for SBU. SBU and Z-Prime Plus provided higher bond strength values to zirconia. The lowest values were obtained with Signum Zirconia Bond, followed by MZ Primer. The use of silane, prior to the SBU, did not significantly increase the bond strength to zirconia ceramic. / O objetivo do estudo foi avaliar a resist?ncia de uni?o do adesivo Single Bond Universal e do adesivo do Adper Scothbond Multi-Purpose, com e sem aplica??o pr?via de silano, sobre a cer?mica feldsp?tica e a resina composta. Tamb?m foi avaliado o efeito de diferentes primers para zirc?nia e de um adesivo universal na resist?ncia de uni?o ? zirc?nia. Sessenta amostras em cer?mica feldsp?tica, 60 amostras em resina composta e 75 amostras em cer?mica de zirc?nia foram inclu?das em resina acr?lica, seguido de polimento com lixas de carbeto de sil?cio de granula??o 600 e 1200. A superf?cie das amostras de cer?mica feldsp?tica foi condicionada com ?cido fluor?drico a 10% por 2 minutos, a superf?cie das amostras de resina composta e zirc?nia foi jateada com ?xido de alum?nio 50 ?m por 5 s. As amostras em cer?mica feldsp?tica e resina composta foram divididas aleatoriamente em quatro grupos (n=15) para cada material: G1 ? Adesivo do Adper Scothbond Multi-Purpose (SBMP); G2 ? Silano + SBMP; G3 ? Single Bond Universal (SBU); G4 ? silano + SBU. As amostras em zirc?nia foram divididas aleatoriamente em cinco grupos (n=15): G1 ? Single Bond Universal (SBU); G2 ? silano + SBU; G3 - Signum Zirconia Bond; G4 - Z-Prime Plus; G5 - MZ Primer. Sobre o material adesivo aplicado na superf?cie das amostras foi constru?do um cone de resina composta. Os corpos de prova foram armazenados em 100% de umidade relativa a 37oC por 48 h e submetidos ao teste de resist?ncia de uni?o ? tra??o em m?quina de ensaio universal com velocidade de 0,5 mm/min. Os tipos de falha foram analisados. Os dados obtidos sobre a cer?mica feldsp?tica e a resina composta foram submetidos ao teste de Kruskal-Wallis, seguido do teste de Mann-Whitney (?=0,05). Os valores de resist?ncia de uni?o (MPa) seguidos de letras distintas diferem estatisticamente entre si: Cer?mica: G2=21,23a, G4=8,87b, G3=3,24c, G1=2,73c. Resina composta: G2=24,59a, G3=20,91ab, G4=19,77bc, G1=17,00c. As falhas foram predominantemente adesivas para a resina composta e para a cer?mica, com exce??o do grupo 2 da cer?mica. Para a s amostras em zirc?nia, os dados foram submetidos ? ANOVA, seguido do teste de Tukey (?=0,05). As m?dias de resist?ncia de uni?o (MPa) seguidas de letras distintas diferem estatisticamente entre si: G2=27,55a, G4=23,71a, G1=22,64a, G5=13,64b, G3=7,54c. As falhas foram predominantemente coesivas no cone de resina composta nos grupos 1, 2 e 4. As falhas foram predominantemente mistas no grupo 5 e, no grupo 3, todas as falhas foram adesivas. A aplica??o isolada do silano previamente aos adesivos proporcionou maior resist?ncia de uni?o com a cer?mica feldsp?tica, j? para a resina composta foi importante para o SBMP e n?o foi para o SBU. O SBU e o Z-Prime Plus proporcionaram os maiores valores de resist?ncia de uni?o ? zirc?nia. Os menores valores foram obtidos com o Signum Zirconia Bond, seguido do MZ Primer. O uso de silano previamente ao SBU n?o proporcionou aumento significativo na resist?ncia de uni?o ? zirc?nia.
120

Entendendo as propriedades do arenito Botucatu e sua utiliza??o como meio poroso para estudos envolvendo o deslocamento de fluidos polim?ricos

Cardoso, Oldemar Ribeiro 21 February 2014 (has links)
Made available in DSpace on 2014-12-17T15:42:30Z (GMT). No. of bitstreams: 1 OldemarRC_TESE.pdf: 3699257 bytes, checksum: 0779dc655c0cadfa72a92f99bc053514 (MD5) Previous issue date: 2014-02-21 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / The development of products whose purpose is to promote blockages in high permeability zones as well as to control the hydrate or scale formation also needs some tests in porous media before using the product in the field, where attempts and unavoidable operational errors costs would able to derail any projects. The aim of this study was to analyze and compare the Botucatu and Berea sandstones properties, involving problems related to loss permeability. It was observed that even cores of Berea, without expansible clays in their composition had their permeability reduced, as soon as the salinity of brine reached a lower limit. As expected, the same happened with the Botucatu sandstone samples, however, in this case, the sensitivity to low salinity was more pronounced. In a second phase, the research was focused on the Botucatu Sandstone behavior front of dilute polymer solutions injection, checking the main relationships between the Rock / Fluid interactions, considering the Mobility Reduction, Resistance and Residual Resistance Factors, as well as adsorption/desorption processes of these polymers, and the polymer molecules average size and porous sandstone average size ratio. The results for both phases showed a real feasibility of using the Botucatu sandstone in laboratory tests whose objective is the displacement of fluids through porous media / O desenvolvimento de produtos cuja finalidade ? a de promover bloqueios em ?reas de alta permeabilidade, assim como de controladores ou inibidores de corros?o e incrusta??o e de hidratos, tamb?m necessita de estudos no meio poroso, antes de serem empregados em opera??es de campo. Considerando esses aspectos, o presente trabalho teve como principal objetivo compreender melhor a natureza do arenito Botucatu, buscando, na medida do poss?vel: (a) tra?ar compara??es entre o seu comportamento e o comportamento do arenito Berea, o mais popular entre os pesquisadores e (b) considerando sua abund?ncia no Brasil e facilidade de explora??o, refor?ar a possibilidade de seu uso seguro como meio poroso virgem em ensaios de laborat?rio, visando an?lises e qualifica??o de materiais pass?veis de serem usados na ind?stria do petr?leo. Em plugs desse arenito, foram injetadas solu??es aquosas de v?rias salinidades, tendo como ponto de partida a ?gua do mar sint?tica, com o objetivo de se detectar poss?veis altera??es na permeabilidade do arenito devido ? expans?o de argilas ou ? libera??o de part?culas capazes de tamponar definitiva ou temporariamente as gargantas dos poros da rocha, bem como comparar seu comportamento com outros arenitos normalmente utilizados para estudos envolvendo meio poroso. Para tanto, em uma segunda fase, foram utilizados pol?meros regularmente empregados na ind?stria do petr?leo (as poliacrilamidas), onde se procurou verificar se o comportamento desses materiais em solu??o, e n?o mais somente a ?gua, quando empregados no meio poroso representado pelo arenito Botucatu, retratava com fidelidade e seguran?a os resultados reportados na literatura especializada para os meios porosos tradicionais. Os resultados para ambas as fases mostraram uma real viabilidade do emprego do arenito Botucatu em an?lises de laborat?rio cujo objetivo seja o deslocamento em meio poroso

Page generated in 0.0689 seconds