• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 192
  • 1
  • Tagged with
  • 193
  • 193
  • 136
  • 114
  • 87
  • 80
  • 74
  • 71
  • 57
  • 50
  • 50
  • 48
  • 47
  • 45
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Deposi??o e caracteriza??o de revestimentos de Ni-Ti e Ni-Ti/Nb para aplica??es biom?dicas

Vargas, Andr? Lu?s Marin 30 August 2007 (has links)
Made available in DSpace on 2015-04-14T13:59:19Z (GMT). No. of bitstreams: 1 396764.pdf: 5447809 bytes, checksum: 95a031242ec95fc4971f2c3bd2c511a0 (MD5) Previous issue date: 2007-08-30 / Entre as ligas de mem?ria de forma (SMA shape memory alloys) as de n?quel-tit?nio (Ni-Ti) s?o as mais importantes e pr?ticas devido, principalmente, ?s suas excelentes propriedades mec?nicas, excelentes propriedades que resistem ? corros?o, etc. A import?ncia dessas ligas, al?m do efeito de mem?ria de forma (SME), tamb?m est? relacionada aos efeitos de Superelasticidade ou Pseudoelasticidade (PE), o que permite a esse material alterar suas fases sob condi??es espec?ficas e retornar ? sua forma original. Essas ligas s?o utilizadas em aplica??es biom?dicas (material em volume), e em diversos campos da micro engenharia. Entretanto, filmes finos de NiTi s?o raramente utilizados em aplica??es biom?dicas, em sua maioria devido ? dificuldade em produzir filmes capazes de produzirem os mesmos efeitos encontrados no material em volume. Para tal, ? preciso alterar as concentra??es at?micas dos filmes de maneira precisa, a fim de se obter a fase cristalina necess?ria para a ocorr?ncia de tais efeitos. Outra possibilidade ? a utiliza??o de filmes do tipo multicamada, os quais s?o produzidos em sua maioria pela t?cnica de Magnetron Sputtering, aliado a um tratamento t?rmico espec?fico, o que possibilita a transforma??o de uma estrutura amorfa para uma cristalina. O objetivo deste trabalho ? depositar filmes finos monol?ticos e do tipo multicamada de Ni-Ti/Ti e NiTi/Nb pela t?cnica de DC Magnetron Sputtering para aplica??es biom?dicas e caracterizar propriedades mec?nicas de dureza e m?dulo de elasticidade, composi??o qu?mica e estrutura cristalina, e a resist?ncia ? corros?o dos mesmos antes e ap?s o tratamento t?rmico das ligas depositadas. Medidas de difra??o de raios X (DRX), e de fluoresc?ncia de raios X (FRX), mostraram que a estrutura cristalina e a composi??o foram obtidas com sucesso. As propriedades mec?nicas e de resist?ncia ? corros?o apresentadas por estes revestimentos mostraram caracter?sticas excelentes de biocompatibilidade. Os ensaios de corros?o foram feitos segundo as recomenda??es contidas na norma ASTM F746.
102

Avalia??o da resist?ncia ? fratura de molares endodonticamente tratados com preparo MOD transfixados por um pino de fibra de vidro e restaurados com diferentes materiais

F?vero, Fernando Jos? 20 January 2017 (has links)
Submitted by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-05-05T17:20:11Z No. of bitstreams: 1 TES_FERNANDO_JOSE_FAVERO_PARCIAL.pdf: 219648 bytes, checksum: c82c65601bd3d6d321aa7ab11b1a88c2 (MD5) / Made available in DSpace on 2017-05-05T17:20:11Z (GMT). No. of bitstreams: 1 TES_FERNANDO_JOSE_FAVERO_PARCIAL.pdf: 219648 bytes, checksum: c82c65601bd3d6d321aa7ab11b1a88c2 (MD5) Previous issue date: 2017-01-20 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Objetivos: 1) Avaliar ? resist?ncia ? fratura de molares endodonticamente tratados com preparos cavit?rios MOD e restaurados com Riva light cure (RLC) ou Riva Silver (RS) com e sem a presen?a de pino de fibra de vidro transfixado associado ? resina Bulk Fill Flow; 2) Avaliar o padr?o de fratura ap?s o ensaio mec?nico. Materiais e M?todos: Cinquenta terceiros molares supeiores extra?dos foram divididos em 5 grupos (n=10 por grupo): H?gidos (H); Preparo MOD (MOD) + Tratamento endod?ntico (TE) + cimento de ion?mero de vidro Riva Light Cure (GI); MOD + TE + cimento de ion?mero de vidro Riva Silver (GIS); MOD + TE + resina Bulk Fill Flowable (BFF) + pino de fibra de vidro horizontal (TFP) + RLC (GIP); MOD + TE + BFF + TFP + RS (GISP). Os preparos cavit?rios MOD e os tratamentos endod?nticos foram realizados em todos os grupos, exceto os h?gidos. A face vestibular e palatina dos grupos (GIP) e (GSIP) receberam a transfixa??o horizontal do pino de fibra de vidro seguido da inser??o da resina composta Bulk Fill Flow, Riva light cure ou Riva Silver de acordo com os grupos de estudo. Os dentes foram submetidos ao teste de resist?ncia ? fratura em uma m?quina de ensaio universal. O tipo de fratura ap?s o ensaio foi classificado em: fratura em assoalho pulpar (condenados) ou em c?spide (recuper?vel). Resultados: M?dias em Newtons(N) seguidas de mesma letra n?o apresentam diferen?a estat?stica para ANOVA e Tukey (P<0,05%): H 3955,6NA; GI 1215,6NB; GIS 1195,8NB; GIP 2064,6NC GISP 2386,5NC. O padr?o de fratura foi similar entre os grupos testados com 54% de fraturas recuper?veis e 46% para dentes condenados. Conclus?es: A associa??o do pino de fibra de vidro, resina Bulk Fill flow, Riva light cure (GIP) ou Riva Silver (GISP) recuperou, respectivamente 52,19%, e 60,23% da resist?ncia ? fratura de um dente h?gido, sendo, em m?dia, 2x maior que os resultados dos grupos (GI) e (GIS). / Objetivos: 1) Avaliar a resist?ncia ? fratura de terceiros molares com preparos cavit?rios MOD tratados endodonticamente e restaurados com resina composta de forma direta, cimento de ion?mero de vidro modificado por resina ou cimento de ion?mero de vidro tipo silver com e sem a presen?a de pino de fibra de vidro transfixado horizontalmente em molares endodonticamente tratados; 2) Avaliar o padr?o de fratura dos dentes ap?s o ensaio de resist?ncia ? fratura. Materiais e M?todos: Setenta molares h?gidos extra?dos foram embutidos em resina acr?lica e divididos em 7 grupos (n=10 por grupo): H?gidos (H); preparo cavit?rio (MOD) + Tratamento endod?ntico (TE) + restaura??o com resina composta Z250 (RC); MOD + TE + cimento de ion?mero de vidro Riva Light Cure (GI); MOD + TE + Cimento de ion?mero de vidro Riva Silver (GIS); MOD + TE + pino de fibra de vidro transfixado (TFP) + RC (RCP); GI + TFP (GIP); GIS + TFP (GISP). Os preparos cavit?rios MOD foram padronizados com largura 2/3 da dist?ncia vest?bulo-lingual, tendo como refer?ncia a ponta das respectivas c?spides, e profundidade ocluso-gengival de 4mm permanecendo 2mm acima do limite amelo-cement?rio. Foram realizados tratamentos endod?nticos em todos os grupos, exceto para o grupo dos dentes h?gidos. Os grupos (RCP), (GIP) e (GSIP) receberam pinos de fibra de vidro transfixados horizontalmente e ap?s foram restaurados com Z250, Riva Light Cure ou Riva Silver, respectivamente. Ap?s, os dentes foram submetidos ao ensaio de resist?ncia ? fratura em uma m?quina de ensaio universal. Ap?s realiza??o dos ensaios, os dentes foram inspecionados quanto ao tipo de fratura e classificados em: Fratura em assoalho pulpar (N?o recuper?vel) ou C?spide (Recuper?vel). Resultados: M?dias seguidas de mesma letra n?o apresentam diferen?a estat?stica para ANOVA e Tukey (p>0,05): (H) 3901NA; (RC) 1232NB; (GI) 1251NB; (GIS) 1259NB; (GISP) 2168NC; (RCP) 2230NC; (GIP) 2292NC. O padr?o predominante de fratura foi em c?spide. Conclus?es: A utiliza??o do pino de fibra de vidro restaurado com resina composta (RCP), Riva Light Cure (GIP) e Riva Silver (GISP) recuperou, respectivamente, 57,16%, 58,75% e 55,56% da resist?ncia ? fratura de um dente h?gido, enquanto os dentes restaurados sem pino recuperaram para os grupos (RC), (GI) e (GIS), 31,53%, 32,07% e 34,84%. O progn?stico predominante foi recuper?vel para todos os grupos, exceto (GIS). / Objectives: 1) To assess the fracture strength of third molars with endodontically treated MOD cavity preparations and restored with direct composit resin, resin modified glass ionomer cement or silver glass ionomer cement with and without the presence of fiberglass post transfixed horizontally in endodontically treated molars; 2) To assess the fracture pattern of the teeth after the fracture resistance test. Materials and Methods: Seventy extracted healthy third molars were embedded in acrylic resin and divided into 7 groups (n = 10 per group): Healthy (H); Cavity preparation (MOD) + Endodontic treatment (ET) + restoration with Z250 composit resin (RC); MOD + TE + glass ionomer cement Riva Light Cure (GI); MOD + TE + Riva Silver glass ionomer cement (GIS); MOD + TE + transfixed fiberglass post (TFP) + RC (RCP); GI + TFP (GIP); GIS + TFP (GISP); MOD cavity preparations were standardized with a width of 2/3 fo the vestibular-lingual distance, with reference to the tip of the respective cusps, and occlusal-gingival depth of 4mm remaining 2mm above the cemento-enamel junction. Endodontic treatments were performed in all groups, except for the healthy teeth group. The groups (RCP), (GIP) and (GISP) received horizontally transfixed fiberglass posts and afterwards were restored with Z250, Riva Light Cure or Riva Silver, respectively. Afterwards, the teeth were submitted to the fracture strength test in a universal test machine. After the tests were performed, the theeth were inspected for the type of fracture and classified as: Fracture in the pulpal floor (Not-recoverable) or cusps (Recoverable) Results: Averages followed by the same letter did not present statistical difference for ANOVA and Tukey (p>0,05): (H) 3901NA; (RC) 1232NB; (GI) 1251NB; (GIS) 1259NB; (GISP) 2168NC; (RCP) 2230NC; (GIP) 2292NC. The predominant pattern of fracture was cusps. Conclusions: The use of the fiberglass post restored with composite resin (RCP), Riva Light Cure (GIP) and Riva Silver (GISP) recovered, respectively 57.16%, 58.75% and 55.56% of resistance to the fracture of a healthy tooth, whereas the restored teeth without post recovered for the groups (CR), (GI) and (GIS), 31.35%, 32.07% and 34.84%. The predominant prognosis was recoverable for all groups, except (GIS). / Objetivos: 1) To assess the fracture strength of endodontically treated molars with MOD cavity preparations and restored with Riva Light Cure (RLC) ou Riva Silver (RS) with and without the presence of transfixed fiberglass post associated with Bulk Fill Flow resin; 2) To assess the fracture pattern after the mechanical test. Materials and Methods: Fifty third molars extracted were divided into 5 groups (n = 10 per group): Healthy (H); Preparation MOD (MOD) + Endodontic Treatment (TE) + glass ionomer cement Riva Light Cure (GI); MOD + TE + Riva Silver glass ionomer cement (GIS); MOD + TE + BulkFill Flowable resin (BFF) + horizontal fiberglass post (TFP) + RLC (GIP); MOD + TE + BFF + RS (GISP). MOD cavity preparations and endodontic treatments were performed in all groups, except for the healthy ones. The vestibular and palatine face of the (GIP) and (GISP) groups received the horizontal transfixation of the fiberglass post followed by the insertion of the composite resin Bulk Fill Flow, Riva Light Cure or Riva Silver according to the study groups. The teeth were submitted to the fracture strength test in a universal test machine. The type of fracture after the test was classified as: pulpal floor fracture (condemned) or cuspal fracture(recoverable). Results: Averages in Newtons (N) followed by the same letter did not present statistical difference for ANOVA and Tukey (P<0,05%): H 3955,6NA; GI 1215,6NB; GIS 1195,8NB; GIP 2064,6NC GISP 2386,5NC. The fracture pattern was similar between the groups tested with 54% of recoverable fractures and 46% for condemned teeth. Conclusions: The association of fiberglass post, BulkFill Flowable resin, Riva Light Cure (GIP) ou Riva Silver (GISP) recovered respectively 52.19% and 60.23% of the fracture resistance of a healthy tooth, being, on overage, 2x greater than the results of the groups (GI) and (GIS).
103

Efeito do plasma rico em plaquetas no reparo do tend?o de aquiles em ratos

Dietrich, Franciele 26 July 2017 (has links)
Submitted by PPG Medicina e Ci?ncias da Sa?de (medicina-pg@pucrs.br) on 2017-11-23T10:48:18Z No. of bitstreams: 1 FRANCIELE_DIETRICH_TES.pdf: 3499792 bytes, checksum: c6cf1d1c8ad84ed3af5c5b4a075c3eb9 (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-12-01T11:50:39Z (GMT) No. of bitstreams: 1 FRANCIELE_DIETRICH_TES.pdf: 3499792 bytes, checksum: c6cf1d1c8ad84ed3af5c5b4a075c3eb9 (MD5) / Made available in DSpace on 2017-12-01T11:54:10Z (GMT). No. of bitstreams: 1 FRANCIELE_DIETRICH_TES.pdf: 3499792 bytes, checksum: c6cf1d1c8ad84ed3af5c5b4a075c3eb9 (MD5) Previous issue date: 2017-07-26 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The increasing incidence of tendon injuries is a constant challenge in orthopaedic medicine. The use of platelet-rich plasma (PRP) is a strategy widely explored in the clinic because it is believed to accelerate the tendon repair process. However, the PRP clinical efficacy is uncertain, and more studies that aim to a better understanding of this treatment are needed. The aim of this research was to evaluate the PRP effect on the Achilles tendon (AT) repair of rats. A total of 242 rats were used, where 181 animals were randomly distributed in 6 different experiments. The remaining animals were used as blood donors (n=49) and for flow cytometry (n=12). The lesion was performed by transection of the right AT. The repair evaluation occurred after 11 and 14 postoperative days, with a mechanical testing machine. Peak force was considered the primary variable. Variations in the PRP production protocols, leukocyte concentration and physical activity of the rats were tested. ELISA test was performed to quantify platelet-derived growth factor (PDGF-AB) present in PRP. Pathogenfree animals and animals contaminated with Staphylococcus aureus (S. aureus) were used. Standard PRP platelet concentration was at least 5 times higher than that of the peripheral blood, and it was possible to have either a high or a low leukocyte concentration in the preparation. PDGF-AB levels in inactivated PRP were 7.3 ?g/mL (SD 6.0; n=4) and in plasma were below the detection levels (0.03 ng/mL). In the experiments performed with pathogen-free rats, no significant effect of PRP could be observed on tendon repair. In the same way, no significant difference could be found in the rats treated with PRP with higher or lower leukocyte concentration. In contrast, rats contaminated with S. aureus showed increased tendon force after PRP treatment. Significant interaction between bacteriological status and PRP treatment was verified (p=0.003). It was further observed that healthy rats had higher levels of cytotoxic T cells in their spleens. The difference in response to treatment in contaminated rats suggests that the PRP effect is dependent on the immune status of the animals. This is the first study that suggests the possibility of interaction between microbiota and tendon repair. Extrapolation of this treatment to the clinic remains dubious. / A crescente incid?ncia de les?es tend?neas constituem um desafio constante na medicina ortop?dica. A utiliza??o do plasma rico em plaquetas (PRP) ? uma estrat?gia amplamente explorada na cl?nica por creditar-se que acelera o processo de reparo tend?neo. Contudo, a efic?cia cl?nica do PRP ? question?vel, e mais estudos que visem uma melhor compreens?o deste tratamento s?o necess?rios. O objetivo desta pesquisa foi avaliar o efeito do PRP no reparo do tend?o de Aquiles (TA) de ratos. Um total de 242 ratos foram utilizados, sendo 181 animais randomicamente distribu?dos em 6 diferentes experimentos. Os animais restantes foram utilizados como doadores sangu?neos (n= 49) e para realiza??o de citometria de fluxo (n=12). A les?o foi executada atrav?s de transec??o do TA direito. A avalia??o do reparo foi feita 11 e 14 dias p?s-cir?rgico, atrav?s de m?quina de teste mec?nico. O pico de for?a foi considerado a vari?vel principal. Varia??es no protocolo de produ??o de PRP, concentra??o de leuc?citos e atividade f?sica dos ratos foram testados. O teste de ELISA foi realizado a fim de quantificar o fator de crescimento derivado das plaquetas (PDGF-AB) presente no PRP. Foram utilizados animais livres de pat?genos e animais contaminados com Staphylococcus aureus (S. aureus). A concentra??o plaquet?ria do PRP padr?o foi pelo menos 5 vezes maior que a do sangue perif?rico, e foi poss?vel obtermos tanto uma alta ou baixa concentra??o de leuc?citos no preparado. Os n?veis de PDGF-AB no PRP inativado foram de 7.3 ?g/mL (DP 6.0; n=4) e no plasma sangu?neo foram abaixo dos n?veis de detec??o (0.03 ng/mL). Nos experimentos realizados com ratos livres de pat?genos, nenhum efeito significativo do PRP p?de ser observado no reparo tend?neo. Da mesma forma, nenhuma diferen?a significativa p?de ser encontrada nos ratos tratados com PRP com alta ou baixa concentra??o de leuc?citos. Em contraste, os ratos contaminados com S. aureus demonstraram aumento da for?a tend?nea ap?s o tratamento com PRP. Significante intera??o entre estado bacteriol?gico e tratamento PRP foi verificada (p=0.003). Observou-se ainda, que ratos saud?veis possu?am maiores n?veis de c?lulas T citot?xicas em seus ba?os. A diferen?a na resposta ao tratamento em ratos contaminados sugere que o efeito do PRP ? dependente do estado imune dos animais. Esse ? o primeiro estudo que sugere a possibilidade de intera??o entre microbiota e reparo tend?neo. A extrapola??o deste tratamento para a cl?nica permanece d?bia.
104

Elucida??o do mecanismo de resist?ncia de Mycobacterium tuberculosis frente a novos compostos com atividade antimicobacteriana

Abbadi, Bruno Lopes 19 January 2018 (has links)
Submitted by PPG Biologia Celular e Molecular (bcm@pucrs.br) on 2018-03-05T13:21:28Z No. of bitstreams: 1 BRUNO_LOPES_ABBADI_TES.pdf: 4934736 bytes, checksum: 58e4c3c86d9fb96bb1476ae3c18bfdf0 (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2018-03-06T16:15:19Z (GMT) No. of bitstreams: 1 BRUNO_LOPES_ABBADI_TES.pdf: 4934736 bytes, checksum: 58e4c3c86d9fb96bb1476ae3c18bfdf0 (MD5) / Made available in DSpace on 2018-03-06T16:21:42Z (GMT). No. of bitstreams: 1 BRUNO_LOPES_ABBADI_TES.pdf: 4934736 bytes, checksum: 58e4c3c86d9fb96bb1476ae3c18bfdf0 (MD5) Previous issue date: 2018-01-19 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Epidemiologic data regarding tuberculosis (TB) show that there is still a high burden of this disease worldwide. In addition, the emergence of drug-resistant strains imposes a new threat in preventing TB spread. Therefore, it is pivotal to continuously find new candidates for drug development. In the Chapter 2 of this thesis, the compound IQG-607 is presented, which is a metal complex that has been reported as a promising anti-TB molecule against isoniazid (INH)-resistant strains of M. tuberculosis. Previous studies suggested that the compound inhibits both the wild-type NADH-dependent trans-2-enoyl-[ACP] reductase (InhA) enzyme and some of its structural mutants in the absence of NAD+ or NADH and without requiring KatG enzyme. IQG-607 has also shown a favorable toxicological profile in vivo, with a considerable lesser toxicity compared to INH. However, there is still a gap regarding the activity of IQG-607 against strains carrying mutations in the katG gene, which are the most common genetic alterations in clinical isolates resistant to INH. Therefore, this study focused in elucidating the mechanism of resistance (MOR) of the Mycobacterium tuberculosis, the main causative agent of TB, to compound IQG-607. First the minimum inhibitory concentration (MIC) of IQG-607 was established against eight multi-drug resistant (MDR) clinical isolates, which were resistant to our compound. Then spontaneous mutants were selected using high concentrations of compound in 7H10 agar medium, and their whole genomes were sequenced; the results revealed alterations in the katG gene. A laboratory strain carrying the mutant katG(S315T) gene was developed to assess the effect of this single mutation in the compound activity both by MIC determination and by a macrophage infection model. Results showed that this mutation was indeed sufficient to confer resistance to IQG-607. Finally, the resistance observed for a strain expressing a mutant InhA(S94A) protein suggested that IQG-607 has this enzyme as its molecular target. In the Chapter 3, two new compounds, called Labio-16 and Labio-17, are presented, which were previously selected to interact and inhibit the InhA enzyme and that had already shown to be active against M. tuberculosis H37Rv strain. A set of experiments were conducted to elucidate their mechanism of action (MOA) and to understand the MOR of the M. tuberculosis against them, similar to those carried for studying IQG-607. So far, results suggested that the InhA is not the molecular target of these compounds. Other experiments are undergoing in our laboratory to evaluate in a murine model of TB infection their potential as anti-TB drug candidates. / Os dados epidemiol?gicos relacionados ? tuberculose (TB) indicam que ainda existe uma carga elevada desta doen?a no mundo todo. Al?m disso, o surgimento de cepas resistentes aos f?rmacos imp?e uma nova amea?a na preven??o da propaga??o da TB. Portanto, ? fundamental buscar continuamente novos candidatos para o desenvolvimento de medicamentos. No Cap?tulo 2 desta tese ? apresentado o composto IQG-607, que ? um complexo met?lico que tem sido reportado como uma mol?cula anti-TB promissora contra cepas de M. tuberculosis resistentes ? isoniazida (INH). Estudos pr?vios sugeriram que o composto inibe a enzima selvagem trans-2-enoil-[ACP] redutase dependente de NADH (InhA) e algumas das suas mutantes estruturais, na aus?ncia de NAD+ ou NADH e sem necessitar da enzima KatG. O IQG-607 tamb?m mostrou um perfil toxicol?gico favor?vel in vivo, com uma menor toxicidade em compara??o ? INH. No entanto, ainda existe uma lacuna em rela??o ? atividade do IQG-607 contra cepas que carregam muta??es no gene katG, as quais s?o as altera??es gen?ticas mais comuns em isolados cl?nicos resistentes ? INH. Sendo assim, este estudo focou em elucidar o mecanismo de resist?ncia (MOR) do Mycobacterium tuberculosis, o principal agente causador da TB, ao composto IQG-607. Primeiramente, a concentra??o inibit?ria m?nima (MIC) do IQG-607 foi estabelecida contra oito isolados cl?nicos multirresistentes a f?rmacos (MDR), os quais foram resistentes ao nosso composto. Ent?o, mutantes espont?neos foram selecionados, usando-se altas concentra??es do composto em meio ?gar 7H10, e seus genomas completos foram sequenciados; os resultados revelaram altera??es no gene katG. Uma cepa laboratorial, carregando o gene katG(S315T) mutante, foi desenvolvida para acessar o efeito desta ?nica muta??o na atividade do composto, atrav?s da determina??o de MIC e por meio de um modelo de infec??o de macr?fagos. Os resultados mostraram que essa muta??o de fato foi suficiente para conferir resist?ncia ao IQG-607. Finalmente, a resist?ncia observada para a cepa que expressa a prote?na InhA(S94A) mutante sugeriu que o IQG-607 tem esta enzima como seu alvo molecular. No Cap?tulo 3, dois novos compostos, denominados Labio-16 e Labio-17, s?o apresentados, os quais foram previamente selecionados para interagir e inibir a enzima InhA, e que j? tinham mostrado ser ativos contra a cepa H37Rv de M. tuberculosis. Um conjunto de experimentos foi conduzido para elucidar os seus mecanismos de a??o (MOA) e para compreender o MOR do M. tuberculosis contra eles, similar ?quele usado para estudar o IQG-607. At? o momento, os resultados sugerem que a InhA n?o ? o alvo molecular desses compostos. Outros experimentos est?o em andamento em nosso laborat?rio, para avaliar em um modelo murino da infec??o da TB os seus potenciais como candidatos a f?rmacos anti-TB.
105

Identifica??o e determina??o de resist?ncia antimicrobiana em isolados nosocomiais de Acinetobacter baumannii

Raro, Ot?vio Hallal Ferreira 30 September 2011 (has links)
Made available in DSpace on 2015-04-14T14:51:15Z (GMT). No. of bitstreams: 1 437674.pdf: 1507951 bytes, checksum: 2f5468fe0bdb2401a723df07c96e2c43 (MD5) Previous issue date: 2011-09-30 / Acinetobacter baumannii is an important opportunistic pathogen commonly associated with nosocomial infections, especially in patients hospitalized in intensive care units (ICUs). This microorganism is renowned for its ability to survive under adverse conditions in the environment for extended periods, as well as to rapidly acquire resistance to antimicrobial drugs. Nowadays, the increasing antimicrobial resistance of A. baumannii has been a great challenge for the medical community, since there are few effective options for the treatment of infections caused by this organism. The aim of this study was to evaluate the presence of the A. baumannii from an ICU environment and to characterize the antimicrobial drug resistance of the isolates obtained, as well as of the isolates from patients in ICU of the same hospital in which it was collected environmental samples. For this, 886 environmental and gloves samples were collected from an ICU of S?o Lucas Hospital, Porto Alegre, Brazil, and 46 clinical isolates were obtained from the Laboratory of the same hospital. After the identification of the isolates as A. baumannii by PCR using as target 16S rDNA and blaOXA-51 genes, the resistance to 20 antimicrobial drugs and the production of metallo-beta-lactamases were evaluated in isolates presenting carbapenem reduced susceptibility. Also, it was evaluated the presence of integrons and blaOXA-23 and blaIMP genes by PCR. A. baumannii was identified in 9.6% of environmental and glove samples collected. High percentage of multiresistant (MDR) isolates was found, as well as it was detected high rates of reduced susceptibility to carbapenems. All 89 isolates integron positive were MDR. Between isolates with reduced susceptibility to carbapenems, all presented blaOXA-23, and 41.4% non-clinical and 54% clinical carried the blaIMP. High resistance to polymyxin B was detected, mainly in non-clinical isolates. Although high prevalence has been found in clinical and non-clinical isolates, the latter constitute a great concern, because they can indicate the hospital environment as a reservoir of MDR A. baumannii. / Acinetobacter baumannii ? um importante pat?geno oportunista comumente associado a infec??es nosocomiais, especialmente em pacientes hospitalizados em unidades de tratamento intensivo (UTIs). Este organismo ? reconhecido por sua capacidade de sobreviver em condi??es adversas no ambiente por per?odos prolongados, bem como de facilmente adquirir resist?ncia a drogas antimicrobianas. Atualmente, a crescente resist?ncia antimicrobiana de A. baumannii tem constitu?do um grande desafio para a comunidade m?dica, uma vez que existem poucas op??es efetivas para o tratamento de infec??es causadas por este microrganismo. O objetivo deste estudo foi avaliar a presen?a de A. baumannii no ambiente de uma UTI e caracterizar a resist?ncia a drogas antimicrobianas dos isolados obtidos, bem como de isolados de pacientes internados na UTI do mesmo hospital no qual as amostras ambientais foram coletadas. Para tanto, 886 amostras ambientais e de luvas foram coletadas de uma UTI do Hospital S?o Lucas, Porto Alegre, Brasil, e 46 isolados cl?nicos foram obtidos no Laborat?rio do mesmo hospital. Ap?s a identifica??o dos isolados como A. baumannii atrav?s de PCR utilizando como alvos os genes rDNA 16S e blaOXA-51, foram determinadas a resist?ncia a 20 drogas antimicrobianas previstas pelo CLSI e a produ??o de metalo-betalactamases em isolados com suscetibilidade reduzida aos carbapen?micos. Tamb?m foi avaliada a presen?a de integrons e dos genes blaOXA-23 e blaIMP atrav?s de PCR. A. baumannii foi identificado em 9,6% das amostras ambientais e de luvas coletadas. Obteve-se um alto percentual de isolados multirresistentes (MDR), assim como foram detectadas alta taxas de suscetibilidade reduzida aos carbapen?micos. Todos os 89 isolados que apresentaram integrons foram MDR. Dentre os isolados com suscetibilidade reduzida aos carbapen?micos, todos apresentaram o gene blaOXA-23, e 41,4% n?o-cl?nicos e 54% cl?nicos carrearam o gene blaIMP. Alta resist?ncia ? polimixina B foi detectada, principalmente em isolados n?o-cl?nicos. Embora alta preval?ncia de resist?ncia antimicrobiana tenha sido encontrada em isolados cl?nicos e n?o cl?nicos, os ?ltimos constituem grande preocupa??o, pois podem indicar o ambiente hospitalar como um reservat?rio de A. baumannii MDR.
106

Avalia??o do potencial de utiliza??o do tanino vegetal da ac?cia negra como inibidor do processo de corros?o de a?o ao carbono em presen?a de CO2 a alta press?o

Marcolino, Juliane Bernardes 31 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-08-26T12:43:16Z No. of bitstreams: 1 474158 - Texto Completo.pdf: 30740052 bytes, checksum: 0b50c4fe801d696f16180d6fa641a96c (MD5) / Made available in DSpace on 2015-08-26T12:43:16Z (GMT). No. of bitstreams: 1 474158 - Texto Completo.pdf: 30740052 bytes, checksum: 0b50c4fe801d696f16180d6fa641a96c (MD5) Previous issue date: 2015-03-31 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / In this work, it was evaluated the possibility of using bark of black wattle (Acacia mearnsii) as a corrosion inhibitor in environments with presence of CO2 under high pressure. SAE 1010 carbon steel samples were exposed to two corrosive situations (with and without oxygen) under the conditions of 15 MPa and 70 ?C, with distinct tannin concentrations for different exposure times (168, 360 and 2160 hours). In order to characterize the specimens it was used infrared spectroscopy analysis, Xray diffraction, scanning electron microscopy by field emission, energy dispersive spectroscopy, mass loss and potentiodynamic polarization tests, determining the rate of corrosion and the efficiency tannin as of tannin as inhibitor. The results indicated that the tannin in deaerated environmental has no potential for use as an inhibitor once there was no significant reduction in corrosion rates and, also the formation of ferric-tannates film. Was not observed corrosion rates values, due mass loss, and were classified as severe corrosion, according to values of NACE RP-07-75 and was not inhibition efficiency values higher than 21 % obtained. Nevertheless, in aerated environmental, tannin worked as a barrier to diffusion of O2 and/or complexation of Fe2+ and Fe3+, providing favorable conditions to the formation of FeCO3 film with protective features. The corrosion rates were classified as moderate for 2160 hours, while 168 h and 360 h, as severe, also according to the values of NACE-RP-07-75, reaching values of up to 72% inhibition efficiency. / Neste trabalho, avaliou-se a possibilidade de utiliza??o do tanino vegetal da ac?cia negra (Acacia mearnsii) como inibidor de corros?o em ambientes com a presen?a de CO2 a alta press?o. Corpos de prova de a?o SAE 1010 foram expostos a dois meios corrosivos (sem e com O2) sob condi??es de 15 MPa e 70?C, com diferentes concentra??es de tanino para diferentes tempos de exposi??o (168, 360 e 2160 h). Para caracteriza??o foram realizadas an?lises de espectroscopia de infravermelho, difra??o de raios X, microscopia eletr?nica de varredura por emiss?o de campo, espectroscopia de energia dispersiva, perda de massa e ensaios de polariza??o potenciodin?mica, determinando-se a taxa de corros?o e a efici?ncia do tanino como inibidor. Os resultados indicaram que o tanino, em meio desaerado, n?o apresenta potencial para utiliza??o como inibidor, pois n?o houve redu??o significativa nas taxas de corros?o e tamb?m n?o se observou a forma??o do filme de ferrotanatos. Todos os valores de taxas de corros?o, por perda de massa, foram classificados como corros?o severa, segundo valores da NACE-RP-07-75 e n?o se obteve valores de efici?ncia de inibi??o maiores que 21 %. No entanto, em meio aerado, o tanino atuou como barreira para a difus?o de O2 e/ou na complexa??o dos ?xidos de Fe2+ e Fe3+, formando filmes de ferrotanatos, propiciando condi??es favor?veis para a forma??o do filme de FeCO3 com caracter?sticas protetoras. As taxas de corros?o foram classificadas como moderada para 2160 h, enquanto que para 168 h e 360 h, como severa, tamb?m segundo valores da NACE-RP-07-75, atingindo-se valores de at? 72 % de efici?ncia de inibi??o.
107

Avalia??o da influ?ncia da associa??o de diferentes m?todos de envelhecimento na resist?ncia de uni?o de reparos em resina composta

Balbinot, Carlos Eduardo Agostini 13 August 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-10-23T11:10:19Z No. of bitstreams: 1 475858 - Texto Completo.pdf: 2068340 bytes, checksum: c21728abeb983dd0a87ba3186541f47a (MD5) / Made available in DSpace on 2015-10-23T11:10:19Z (GMT). No. of bitstreams: 1 475858 - Texto Completo.pdf: 2068340 bytes, checksum: c21728abeb983dd0a87ba3186541f47a (MD5) Previous issue date: 2015-08-13 / The aim of the study was to evaluate the association of different aging methods on bond strength values of composite repair, through the use of shear test. 96 samples of rectangular section were made with the microhybrid composite Point 4 (Kerr) and were divided into 8 groups (n = 12) as follows: (1) immersion in distilled water for 7 days; (2) immersion in distilled water for 30 days; (3) immersion in citric acid for 7 days; (4) immersion in boiling water for 8 hours; (5) immersion in distilled water for 30 days plus immersion in citric acid for 7 days; (6) immersion in distilled water for 30 days plus immersion in boiling water for 8 hours; (7) immersion in citric acid for 7 days plus immersion in boiling water for 8 hours and (8) immersion in distilled water for 30 days plus immersion in citric acid for 7 days plus immersion in boiling water for 8 hours. After going through the designated method of aging the treatment of prerepair was conducted with roughening the surface with sandpaper grain silicon carbide 120 and application of the adhesive system Single Bond 2 (3MESPE) and then made a repair with the same composite resin. The samples were tested in a universal testing machine (EMIC) for the shear bond strength test at a loading speed of 1mm / min. After the failure all samples were evaluated in an increase of 35x stereomicroscope and two samples from each group were evaluated in the SEM as surface after aging and after roughening with sandpaper silicon carbide. The results for evaluation of values in the bond strength test were subjected to statistical test analysis of variance (ANOVA) followed by Tukey test (p <0.05) and no significant differences between the groups tested were found. The evaluation of failure occurred in stereomicroscope were made in a descriptive way, with all samples of all groups presented cohesive failures in the aged resin. Conclusion: The association of different aging methods does not influence the bond strength values of resin repairs made when the roughening method simulating diamond burs coarse-grained is used pre-repair. / O objetivo do estudo foi avaliar a influ?ncia da associa??o de diferentes m?todos de envelhecimento nos valores de resist?ncia de uni?o de reparos de resina composta, atrav?s da utiliza??o de teste de cisalhamento. Foram confeccionadas 96 amostras com a resina composta microh?brida Point 4 (Kerr) de sec??o retangular que foram divididas em 8 grupos (n=12) sendo: (1) imers?o em ?gua destilada por 7 dias; (2) imers?o em ?gua destilada por 30 dias; (3) imers?o em ?cido c?trico por 7 dias; (4) imers?o em ?gua em ebuli??o por 8 horas; (5) imers?o em ?gua destilada por 30 dias mais imers?o em ?cido c?trico por 7 dias; (6) imers?o em ?gua destilada por 30 dias mais imers?o em ?gua em ebuli??o por 8 horas; (7) imers?o em ?cido c?trico por 7 dias mais imers?o em ?gua em ebuli??o por 8 horas e (8) imers?o em ?gua destilada por 30 dias mais imers?o em ?cido c?trico por 7 dias mais imers?o em ?gua em ebuli??o por 8 horas. Ap?s passarem pelo m?todo de envelhecimento designado, foi realizado o tratamento de superf?cie pr?-reparo com asperiza??o com lixa de carbeto de sil?cio de granula??o 120 e aplica??o do sistema adesivo Single Bond 2 (3MESPE) e ent?o, confeccionado um reparo com a mesma resina composta. As amostras foram testadas em uma m?quina de ensaio universal (EMIC) para o teste de cisalhamento a uma velocidade de carregamento de 1mm/min. Ap?s a falha todas as amostras foram avaliadas no estereomicrosc?pio com aumento de 35x e duas amostras de cada grupo foram avaliadas em MEV quanto ? superf?cie ap?s o envelhecimento e ap?s a asperiza??o com lixas de carbeto de sil?cio. Os resultados para avalia??o dos valores no teste de resist?ncia de uni?o foram submetidos ao teste estat?stico de an?lise de vari?ncia (ANOVA) seguido do teste de Tukey (p<0,05) e n?o foram encontradas diferen?as significativas entre os grupos testados. A avalia??o no estereomicrosc?pio das falhas ocorridas foram feitas de forma descritiva, sendo que todas as amostras de todos os grupos apresentaram falhas coesivas na resina envelhecida. Conclus?o: a associa??o de diferentes m?todos de envelhecimento n?o influencia nos valores de resist?ncia de uni?o em reparos de resina composta, quando o m?todo de asperiza??o simulando pontas diamantadas de granula??o grossa ? utilizado pr?-reparo.
108

Influ?ncia de diferentes materiais e t?cnicas restauradoras na carga m?xima de carregamento em molares tratados endodonticamente

Bromberg, Carolina Ritter 20 January 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-04-07T18:38:48Z No. of bitstreams: 1 DIS_CAROLINA_RITTER_BROMBERG_PARCIAL.pdf: 119775 bytes, checksum: 01252fee5f06d6e381692a4123b32401 (MD5) / Made available in DSpace on 2016-04-07T18:38:48Z (GMT). No. of bitstreams: 1 DIS_CAROLINA_RITTER_BROMBERG_PARCIAL.pdf: 119775 bytes, checksum: 01252fee5f06d6e381692a4123b32401 (MD5) Previous issue date: 2016-01-20 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Objectives: The aim of this in vitro study was to compare the maximal load resistance of endodontically treated molars restored with: inlays or onlays of Lava Ultimate, composite resin Z350 XT with or without fiberglass post. Methods: Fifty sound extracted third molars were embedded in acrylic resin and divided into 5 groups (n = 10 per group): H = healthy, ON = onlay, IN = inlay, RC = composite resin, PT = fiberglass post + Z350 XT. The MOD preparations and endodontic treatment were performed. Indirect restorations were made through CAD/CAM CEREC system and cemented with SingleBond Universal and RelyX Ultimate under load of 1 kg. Restorations of RC and PT groups were performed by incremental technique and the two posts in the PT group were horizontally transfixed and bonded with flowable resin. Then, mechanical loading in all samples were performed in 500.000 cycles at 200 N at a frequency of 1 cycle / second and the maximum load test was performed in a universal testing machine at a speed of 1 mm / min. After the mechanical test, the faults were categorized into pulpal floor fracture (irreparable) and cuspal fracture (repairable). Results: Mean values were (means followed by the same letter show no significant difference to ANOVA and Tukey): RC 1680N ? 454 d; PT 2693N ? 372 bc; ON 2922N ? 774 b; IN 2053N ? 313 cd; H 4514N ? 548 a. The predominant failure pattern for teeth restored with onlays, inlays and direct composite resin with or without post was the irreparable type. Conclusion: Endodontically treated molars restored with transfixed fiberglass post and composite resin have similar fracture resistance to those restored with indirect Lava Ultimate inlay and onlay. Horizontally fiber post restoration has the same efficiency that onlays restoration. / Objetivos: O objetivo deste estudo foi avaliar e comparar in vitro a resist?ncia m?xima ao carregamento de molares tratados endodonticamente e restaurados com: inlays ou onlays de Lava Ultimate, resina composta Z350 XT com ou sem pino de fibra de vidro transfixado. Materiais e m?todos: Cinquenta terceiros molares h?gidos extra?dos foram inclu?dos em acr?lico autopolimeriz?vel e divididos em 5 grupos (n = 10 por grupo): H = h?gido, ON = onlay, IN = inlay, RC = resina composta, PT = pino de fibra de vidro + Z350 XT. Em seguida, foram realizados os preparos MOD e o tratamento endod?ntico. As restaura??es indiretas foram confeccionadas atrav?s do sistema CAD/CAM CEREC e cimentadas com SingleBond Universal e RelyX Ultimate sob carga de 1 Kg. As restaura??es do grupo RC e PT foram realizadas pela t?cnica incremental e os dois pinos no grupo PT foram transfixados horizontalmente e colados com resina flowable. Ap?s, os corpos de prova foram submetidos a 500.000 ciclos de fadiga mec?nica sob carga vertical de 200 N na frequ?ncia de 1 ciclo/segundo. Na sequ?ncia, foi aplicado o teste de carga m?xima de carregamento em m?quina de ensaio universal a uma velocidade de 1 mm/min. Ap?s o ensaio mec?nico, as falhas foram categorizadas em fratura de assoalho pulpar (irrepar?veis) e fraturas de c?spides (repar?veis). Resultados: Os valores m?dios obtidos foram (m?dias seguidas de mesma letra n?o apresentam diferen?a estat?stica para ANOVA e Tukey): RC 1680N ? 454 d; PT 2693N ? 372 bc; ON 2922N ? 774 b; IN 2053N ? 313 cd; H 4514N ? 548 a. O padr?o de falha predominante para dentes restaurados com onlays, inlays e resina composta direta com ou sem pino foi do tipo irrepar?vel. Conclus?o: Molares endodonticamente tratados e restaurados com pinos de fibra de vidro transfixado e resina composta Z350 XT direta apresentam resist?ncia ? fratura similar ?s restaura??es indiretas tipo inlay e onlay de Lava Ultimate. Restaura??es com pino transfixado horizontalmente possuem a mesma efic?cia que as restaura??es onlays.
109

Avalia??o da influ?ncia do tratamento dentin?rio na ades?o de cimento resinoso auto-adesivo

Gruendling, ?lvaro 15 December 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:24Z (GMT). No. of bitstreams: 1 410872.pdf: 1717876 bytes, checksum: bc2f5803d0c8fa42f01af8f0a4f6b3ae (MD5) Previous issue date: 2008-12-15 / Este estudo teve como objetivo avaliar a influ?ncia do tratamento da superf?cie dentin?ria na resist?ncia de uni?o ao cisalhamento com o uso de um cimento resinoso auto-adesivo. Para tal, foram utilizados 75 incisivos inferiores bovinos, que tiveram a coroa cl?nica seccionada em ?rea quadrangular de 1 cm? e inclu?dos em um tubo de PVC, preenchido com resina acr?lica auto-polimeriz?vel. O esmalte foi desgastado, expondo a superf?cie dentin?ria com lixas de carbeto de sil?cio de granula??o 180, 220 e 400, usadas sequencialmente. As amostras foram divididas em 5 grupos, escolhidas aleatoriamente, de acordo com o tratamento a que foram submetidas: Grupo 1: controle; Grupo 2: jateamento com ?xido de alum?nio; Grupo 3: jateamento com bicarbonato de s?dio; Grupo 4: EDTA; Grupo 5: ?cido poliacr?lico. O cimento resinoso auto-adesivo utilizado foi Rely X Unicem (3M-ESPE). Ap?s inser??o do cimento, os corpos-de-prova foram armazenados em umidade 100% a 37?C por 7 dias. Os ensaios de resist?ncia ao cisalhamento foram realizados em m?quina de ensaios EMIC DL 2000 e os resultados obtidos em MPa. Atrav?s da MEV com magnitude de 50X, foi verificado o tipo de falha que ocorreu na interface dentina/cimento. Ao submeter os resultados ao teste ANOVA, foi poss?vel observar que houve diferen?as estatisticamente significantes entre os grupos (p = 0,007). De acordo com teste de Tukey, o grupo ?xido de alum?nio obteve os maiores valores de resist?ncia de uni?o, estatisticamente diferente (p<0,05) em rela??o aos grupos controle, ?cido poliacr?lico e EDTA, que por sua vez n?o diferiram entre si (p>0,05). O grupo bicarbonato de s?dio n?o diferiu de nenhum grupo e o grupo EDTA obteve os menores valores de resist?ncia de uni?o. As falhas encontradas na interface foram caracterizadas como mistas, e somente o grupo ?xido de alum?nio apresentou presen?a de falhas coesivas em dentina. Concluiu-se que o jateamento com ?xido de alum?nio determinou uma maior resist?ncia de uni?o ao cisalhamento entre substrato dentin?rio/cimento.
110

Resist?ncia ? fratura de ra?zes enfraquecidas restauradas com pinos intra-radiculares e submetidas ? ciclagem mec?nica

Nascimento, Maria Fernanda 11 January 2010 (has links)
Made available in DSpace on 2015-04-14T13:29:33Z (GMT). No. of bitstreams: 1 421649.pdf: 1087640 bytes, checksum: faee9bfd7959d4a4a23ff18aca62f774 (MD5) Previous issue date: 2010-01-11 / Este estudo in vitro avaliou a resist?ncia ? fratura de ra?zes enfraquecidas, tratadas endodonticamente, que foram restauradas com pinos met?licos fundidos e pinos de fibra de vidro Exacto (Angelus Ind?stria de Produtos Odontol?gicos S/A, Londrina, PR, Brasil) e submetidos ? fadiga mec?nica. Foram utilizados 20 dentes humanos unirradiculares, extra?dos, com dimens?es padronizadas e sem defeitos estruturais vis?veis. As coroas foram removidas abaixo da jun??o amelo-cement?ria, mantendo-se comprimento da raiz entre 14 e 16 mm. O tratamento endod?ntico foi realizado pela t?cnica escalonada; os canais foram desobturados para o preparo intra-radicular padronizado com a broca do sistema de pino de fibra de vidro Exacto (no 1,6 mm de di?metro). O enfraquecimento radicular foi realizado com remo??o de dentina dos condutos com uma broca diamantada tronco-c?nica (4 mm de comprimento). As ra?zes foram aleatoriamente divididas em quatro grupos (n=5/grupo) conforme o tipo de pino (met?lico ou pino de fibra de vidro) e o tipo de tratamento realizado (com ciclagem mec?nica ou sem ciclagem mec?nica). Para os pinos met?licos, a regi?o intra-radicular foi modelada e fundida em pe?a ?nica em liga de n?quel-cromo. Os pinos de fibra de vidro receberam complemento coron?rio confeccionado com resina nanoparticulada Z250 (ESPE, 3M) com o uso de coroas de poli?ster pr?-fabricadas com a forma padronizada pelos n?cleos fundidos. Todos os pinos e coroas totais met?licas foram cimentadas com o cimento RelyX Unicem. As ra?zes foram revestidas com uma camada de poli?ter simulando o ligamento periodontal e foram embutidas em resina acr?lica autopolimeriz?vel. Dois grupos foram submetidos ? ciclagem mec?nica no Simulador de Fadiga Mec?nica ERIOS, modelo ER 11000, com protocolo de 300.000 ciclos, carga de 50 N correspondente a press?o de trabalho de 1,13 bars e frequ?ncia de 1 Hz. O ensaio mec?nico para registro dos valores de resist?ncia ? fratura foi realizado com a aplica??o de uma carga compressiva a 450 com a face palatina dos corpos-de-prova em m?quina de ensaio universal ? velocidade de 0,5 mm/min at? que houvesse algum tipo de ruptura. O tipo de falha ap?s o ensaio foi classificado como repar?vel ou irrepar?vel. Os dados de for?a m?xima de ruptura (N) obtidos foram preliminarmente analisados pelos testes de Lilliefors (D) e Shapiro-Wilk (W) quanto ? normalidade de sua distribui??o para aplica??o de testes estat?sticos param?tricos.Posteriormente, foram analisados pelo teste ANOVA de acordo com o delineamento de experimento em blocos casualizados com repeti??es, ao n?vel de signific?ncia de 0,05. Os resultados mostraram que pinos met?licos sem ciclagem mec?nica tiveram a maior resist?ncia ? fratura (484 N); os pinos de fibra de vidro submetidos ? ciclagem mec?nica mostraram os menores valores (259,9 N). Os pinos met?licos fundidos apresentaram maiores valores de resist?ncia ? fratura que os pinos de fibra de vidro; entretanto, apresentaram maior n?mero de falhas irrepar?veis. A ciclagem mec?nica reduziu a for?a m?xima de ruptura, mas n?o afetou o tipo de falha.

Page generated in 0.0648 seconds