Spelling suggestions: "subject:"resist?ncia dde materiais"" "subject:"resist?ncia dee materiais""
31 |
Influ?ncia do tempo de armazenamento na rugosidade, tra??o diametral e compress?o de gessos odontol?gicosCesero, Leonardo de 15 January 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:18Z (GMT). No. of bitstreams: 1
446374.pdf: 760995 bytes, checksum: fdb1e9bc7072bab1285303e1a7f13c42 (MD5)
Previous issue date: 2013-01-15 / The post pouring time to remove dental stone from impression is controversial regardless to strength and roughness. The aim of this study was evaluate the influence of post pouring time in the surface roughness, compressive and diametral tensile strength (DTS) of type IV dental stone. Two hundred and seventy dental stone samples were made from three commercial brands (Durone, Fuji Rock and Tuff Rock). Surface roughness, compressive and diametral tensile strength tests were performed 1 hour, 24 hours and 7 days after pouring. Samples of 6 mm in diameter and 3 mm in height were produced for roughness and DTS tests. Samples of 3 mm in diameter and 6 mm in height were used for compressive strength. Results were submitted to the general linear model and Tukey test (α=0.05). The surface roughness (Ra) registered to different types of dental stone vary from 0.30 μm (Durone 1 hour) to 0.64 μm (Tuff Rock 7 days). The diametral tensile strength (MPa) ranged from 3.94 (Tuff Rock 1 hour) to 9.20 (Durone 7 days). For compressive strength (MPa), data vary from 26.67 MPa (Durone 1 hour) to 65.14 MPa (Fuji Rock 7 days). There was a significant increase of surface roughness (p=0.005), diametral tensile strength (p=0.001) and compressive strength (p=0.001) as time passes after pouring. Commercial brand factor influenced roughness (p=0.001), diametral tensile strength (p=0.004) and compressive strength (p=0.001). Tuff Rock showed the highest surface roughness. The highest DTS was recorded for Durone and Fuji Rock. Fuji Rock showed the highest compressive strength. / O tempo de espera para a remo??o dos modelos de gesso dos moldes em rela??o a sua resist?ncia mec?nica ? controverso. O objetivo desse trabalho foi avaliar a influ?ncia do tempo de armazenamento na rugosidade, tra??o diametral e compress?o de gessos tipo IV. Foram confeccionadas 270 amostras, sendo 90 para cada marca comercial (Durone, Fuji Rock e Tuff Rock). Os testes de rugosidade, tra??o diametral e compress?o para os tempos de armazenagem de 1 hora, 24 horas e 7 dias foram realizados. Para os testes de rugosidade superficial e tra??o diametral amostras de 6 mm de di?metro por 3 mm de altura foram confeccionados. Para o teste de compress?o amostras de 3 mm de di?metro por 6 mm de altura foram utilizadas. Foi utilizado um rugos?metro, para a medi??o da rugosidade m?dia de superf?cie (Ra). Os corpos de prova foram montados na m?quina de ensaio universal e posteriormente realizados os testes de tra??o diametral e compress?o nos respectivos tempos. Os resultados foram submetidos ao modelo linear geral e teste de Tukey (α=0,05). Os valores de rugosidade registrados para os diferentes tipos de gesso variaram de 0,30 μm (Durone 1 hora) ? 0,64 μm (Tuff Rock 7 dias). Os valores de tra??o diametral registrados para os diferentes tipos de gesso variaram de 3,94 MPa (Tuff Rock 1 hora) ? 9,20 MPa (Durone 7 dias). Os valores de compress?o registrados para os diferentes tipos de gesso variaram de 26,67 MPa (Durone 1 hora) ? 65,14 MPa (Fuji Rock 7 dias). Conclu?mos que houve um aumento estatisticamente significante para o fator tempo em rela??o a rugosidade (p=0,005), tra??o diametral (p=0,001) e compress?o (p=0,001). O fator marca comercial influenciou significativamente na rugosidade (p=0,001), tra??o diametral (p=0,004) e compress?o (p=0,001). O gesso Tuff Rock apresentou maior rugosidade, os gessos Durone e Fuji Rock apresentaram o maior valor ? tra??o diametral e o gesso Fuji Rock o maior valor a compress?o.
|
32 |
Avalia??o da aplica??o de uma solu??o experimental inibidora de metaloproteinase na resist?ncia de uni?o mediata de sistemas adesivosMelara, Rafael 21 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:20Z (GMT). No. of bitstreams: 1
447186.pdf: 2766501 bytes, checksum: a394900abd9b1fe55a4a5e1b39342bad (MD5)
Previous issue date: 2013-03-21 / This study aimed to evaluate, in vitro, the mediate microtensile bond strength- μTBS (12 months) of adhesive systems Adper Scotchbond SE / 3M/ESPE (Adper SE) and Adper Scotchbond Multi-Purpose / 3M/ESPE (Adper SMP) to sound dentin surface, treated or not with an experimental acid solution inhibitor of metalloproteinases (MMPs), as well as the predominant pattern of failure by fractography; and evaluate, in vitro, the inhibition of gelatinolytic activity by an experimental acid solution for dentin surface etching containing tetracycline compared with an experimental solution containing tetracycline. For mediate μTBS evaluation, in Adper SE Control and Adper SMP Control groups, the adhesive system was applied according to the manufacturer's instructions. In Adper SE Experimental group was applied the experimental solution prior to the adhesive system, and in the Adper Experimental SMP group, the etching with 37% phosphoric acid was replaced by applying the experimental solution. After applying the adhesive systems, the teeth were prepared for μTBS test, and the sticks were stored in an oven at 37?C. After 12 months μTBS test was realized and the sticks were evaluated by SEM. For enzymatic activity evaluation, saliva samples were collected from healthy donors, centrifuged and the supernatant was used by technique of zymography. This technique was based on the use of electrophoresis, in which a protein substrate (gelatin) was co-polymerized with acrylamide. The enzymes were separated under non-reducing conditions, renatured and then incubated in suitable buffer, based on the association between the substrate digestion and verification of the molecular weight of proteases. To quantify the relative inhibition by the two solutions was used the Image J software (NIH, Bethesda, MD, USA) and compared with the control. For mediate μTBS evaluation, according to the Tukey test (α = 0.05), no difference between the control and experimental groups was found for each adhesive system. The predominant pattern of failure for the system Adper SE was cohesive in composite while for Adper SMP was cohesive in hybrid layer. In the enzymatic activity evaluation, the enzymes were characterized as matrix metalloproteinases, because its expression was inhibited by EDTA (a known inhibitor of MMPs), while NEM (an inhibitor of serine proteases) had no effect on enzymatic activity. The MMP identified in the study, was characterized as MMP-2, with a molecular weight of 62KDa. The experimental acid solution presented an inhibition of the gelatinolytic activity of 93.66% (concentration 0.05%) and 58.58% (0.01% concentration), while the experimental solution had a percentage inhibition of 31.28% and 6.83%, respectively. Based on these results we conclude that after 12 months of storage, the adhesive system Adper SE showed better performance that Adper SMP in the microtensile bond strength test, also seeming to be more effective in maintaining the integrity of the adhesive interface, under fractographic analysis; and that the experimental acid solution for dentin surface etching was capable of almost completely inhibits the enzymatic activity of MMP-2 in a dose dependent manner. / Este estudo teve por objetivo avaliar, in vitro, a resist?ncia de uni?o ? microtra??o (RUM) mediata (12 meses) dos sistemas adesivos Adper Scotchbond SE / 3M/ESPE (Adper SE) e Adper Scotchbond Multi-Uso / 3M/ESPE (Adper SMP) ? superf?cie dentin?ria sadia, tratada ou n?o com uma solu??o ?cida experimental inibidora de metaloproteinases (MMPs), bem como o padr?o predominante de falha por fractografia; e avaliar, in vitro, a inibi??o da atividade gelatinol?tica por uma solu??o ?cida experimental para condicionamento de superf?cie dentin?ria contendo tetraciclina em compara??o com uma solu??o experimental contendo tetraciclina. Para avalia??o da RUM mediata, nos grupos Adper SE Controle e Adper SMP Controle, o sistema adesivo foi aplicado de acordo com as instru??es do fabricante. No grupo Adper SE Experimental foi aplicada a solu??o experimental previamente ao sistema adesivo, e no grupo Adper SMP Experimental, o condicionamento com ?cido fosf?rico a 37% foi substitu?do pela aplica??o da solu??o experimental. Ap?s a aplica??o dos sistemas adesivos, os dentes foram preparados para o teste de RUM, e os palitos obtidos foram armazenados em estufa a 37oC. Ap?s 12 meses, foi realizado o teste RUM e os palitos foram avaliados em MEV. Para avalia??o da atividade enzim?tica, amostras salivares foram coletadas de doadores saud?veis, centrifugadas e o sobrenadante foi usado atrav?s da t?cnica zimogr?fica. Esta t?cnica baseou-se no uso da eletroforese, no qual um substrato proteico (gelatina) foi co-polimerizado com acrilamida. As enzimas foram separadas sob condi??es n?o redutoras, renaturadas e ent?o incubadas em tamp?o adequado, baseando-se na associa??o entre digest?o do substrato e verifica??o do peso molecular das proteases. Para quantificar a inibi??o relativa pelas duas solu??es foi usado o programa Image J (NIH, Bethesda, MD, USA) e comparadas com o controle. Em rela??o ? RUM mediata, de acordo com o teste de Tukey (α=0.05), n?o houve diferen?a entre os grupos controle e experimental para cada sistema adesivo. O padr?o predominante de falha para o sistema adesivo Adper SE foi coesiva em resina composta enquanto que para o Adper SMP foi coesiva em camada h?brida. Na an?lise zimogr?fica, as enzimas foram caracterizadas como metaloproteinases da matriz, pois a sua express?o foi inibida pelo EDTA (um conhecido inibidor de MMPs), enquanto o NEM (um inibidor de proteases serinas) n?o teve nenhum efeito sobre a atividade enzim?tica. A MMP identificada no estudo, foi caracterizada como MMP-2, apresentando um peso molecular de 62KDa. A solu??o ?cida experimental apresentou um percentual de inibi??o da atividade gelatinol?tica de 93.66% (concentra??o de 0.05%) e de 58.58% (concentra??o de 0.01%), enquanto que a solu??o experimental teve um percentual de inibi??o de 31.28% e 6.83%, respectivamente. Com base nos resultados encontrados ? poss?vel concluir que ap?s 12 meses de armazenagem, o sistema adesivo Adper SE mostrou desempenho superior ao Adper SMP no teste de RUM, parecendo tamb?m ser mais efetivo na manuten??o da integridade da interface adesiva, sob an?lise fractogr?fica; e que a solu??o ?cida experimental condicionadora de superf?cie dentin?ria foi capaz de inibir quase completamente a atividade enzim?tica da MMP-2, de uma maneira dose dependente.
|
33 |
Efeito da vibra??o s?nica e ultrass?nica em um adesivo autocondicionante e de frasco ?nico na resist?ncia de uni?o em dentinaCavazzola, Fernanda de C?ssia Mortari 11 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:22Z (GMT). No. of bitstreams: 1
447882.pdf: 1769645 bytes, checksum: 707e21b20055331c157549faf714a8c0 (MD5)
Previous issue date: 2013-03-11 / Purpose: Investigate the influence of bonding systems application activated through a sonic and ultrasonic vibration and a sonic prototype on micro-tensile bond strength in dentin. Materials and Methods: Twenty-four extracted caries-free intact human molar teeth were embedded in a self-cured acrylic resin. The enamel was removed, using wet 220-, and 600-grit abrasive papers. Each adhesive system (self-etching primer and a single bottle total etch) was applied according to the manufacturer's instructions. Then, the groups were classified according to the type and method of application of bonding systems. After the adhesive technique, resin composite was condensed and light-cured for 20s. Afterwards, all specimens were completely included in a self-cured acrylic resin to stabilize the restorative material and the adhesive interface for the serial sections in a cutting machine. These cylinders were stored in distilled water at room temperature 37?C for 24h. The specimens were stressed in the interface between the composite and the dental surface until fracture occurred. The values were recorded in MPa, and submitted to statistical analysis. Data were submitted to Kolmogorov-Smirnov normality test. Two-way ANOVA and Tukey s Test for pairwise multiple comparisons were used (p<0.05). The failure modes were recorded in percentages.Results: The micro tensile bond strengths with sonic vibration were higher than the other groups, showing statistically significant differences. The sonic, ultrasonic and prototype group had more cohesive failure in resin compared to the control group, which had more cohesive failures of the hybrid layer. Conclusion: The application with a sonic vibration is an effective method for the optimization of bond strength in dentin / Objetivo: Verificar se a aplica??o dos sistemas adesivos, por meio da vibra??o do aparelho s?nico, ultrass?nico e de um prot?tipo s?nico aumenta a resist?ncia de uni?o em dentina. A hip?tese experimental ? que a resist?ncia de uni?o nos sistemas adesivos Adper Single Bond 2 e Clearfill SE Bond ? similar tanto nos grupos controle quanto nos grupos que receberem os diferentes tratamentos. Materiais e M?todo: Foram utilizados 24 terceiros molares h?gidos, onde foi realizada a remo??o do esmalte preparando uma superf?cie dentin?ria lisa. Os dentes foram divididos aleatoriamente em 8 grupos, onde cada sistema adesivo foi aplicado de acordo com as recomenda??es do fabricante (aplica??o din?mica manual) e com a vibra??o de aparelho s?nico , ultrass?nico e por um prot?tipo s?nico. Ap?s a t?cnica adesiva, foi aplicada resina charisma A2. As amostras foram inclu?das em resina acr?lica autopolimeriz?vel, preparando um cilindro para os cortes seriados. Estes foram armazenados em ?gua destilada em uma estufa de cultura a 37?C por 24 horas. Ap?s, confeccionou-se os corpos de prova em forma de barra para o ensaio de resist?ncia de uni?o por microtra??o. Os dados obtidos foram submetidos ao teste Kolmogorov-Smirnov para verifica??o de normalidade.A seguir, foram comparados com ANOVA de duas vias e teste de Tukey (p=0,05). A an?lise da fractografia foi realizada porcentualmente. Resultados: A resist?ncia de uni?o do grupo que recebeu a vibra??o s?nica foi maior, apresentando diferen?as estatisticamente significativas, em ambos os sistemas adesivos, comparada com aplica??o din?mica manual e os grupos que receberam tratamento ultrass?nico e do prot?tipo s?nico. Na an?lise fractografia observa-se que os grupos que receberam tratamento s?nico, ultrass?nico e do prot?tipo tiveram maior falha coesiva em resina em rela??o ao grupo controle, que obteve maiores falhas coesivas de camada h?brida. Conclus?o: A utiliza??o da aplica??o s?nica, ? um m?todo eficaz para a otimiza??o da resist?ncia de uni?o em dentina
|
34 |
Influ?ncia do selamento dentin?rio imediato na polimeriza??o de materiais de moldagem e na resist?ncia ? fratura de coroa em cer?micaGhiggi, Paula Cristine 14 March 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:22Z (GMT). No. of bitstreams: 1
448385.pdf: 890714 bytes, checksum: 62d158637f85cd4da3fefcd711a75370 (MD5)
Previous issue date: 2013-03-14 / The first section of this study evaluated the interaction between resin materials used in the immediate dentin sealing (IDS) techniques and impression materials under two different techniques to reduce/eliminate the oxygen-inhibition layer. The occlusal dentin of 35 human molars was exposed and finished with 400 grit silicon carbide sandpaper. Teeth were randomly divided into 2 groups: group 1 impression with vinyl polysiloxane Express XT, group 2 impression with polyether Impregum. Groups 1 and 2 were divided into 14 subgroups: groups 1a e 2a: control groups; groups 1b e 2b: IDS with Clearfil SE Bond (CSE); groups 1c e 2c: IDS with CSE + additional polymerization with glycerine jelly; groups 1d e 2d: IDS with CSE + alcohol; groups 1e e 2e: IDS with CSE and Protect Liner F (PLF); groups 1f e 2f: IDS with CSE and PLF + additional polymerization with glycerin jelly; groups 1g e 2g: IDS with CSE and PLF + alcohol. Each tooth surface was photographed using a digital camera. The images saved were used to examine the presence of impression material left on the treated tooth surface. It was observed that IDS performed with CSE or with the PLF interacted with the Express XT and with the Impregum. The application of glycerine jelly and alcohol avoided the interaction of CSE with the Express XT and of the PLF with the Impregum; however, these treatments were not totally effective to avoid the interaction of CSE with the Impregum and of PLF with the Express XT. The second section of this study evaluate, in vitro, the thickness of the adhesive, low-viscosity microfilled resin, and resin cement on full crown preparations, and its effect on the fracture load of a reinforced all-ceramic crown. Sixty maxillary premolars received full crown preparation and were divided in 3 groups according to the material applied for the immediate dentin sealing: G1 control; G2 CSE Bond; G3 CSE Bond + PLF. After taking the impression with polyvinyl siloxane, the preparations were temporized with acrylic resin crowns. IPS Empress 2 restorations were fabricated, and cemented to the preparations with Panavia F. Ten specimens of each group were submitted to fracture load testing, and the other 10 specimens were sectioned buccolingually, and the thicknesses of Panavia F, CSE Bond and PLF were measured in 10 different positions using a microscope. According to ANOVA and Tukey s test, the fracture load of group 3 (1300 N) was statistically higher than group 1 (1001 N) (p<0.01). Group 2 (1189 N) was not statistically different from groups 1 and 3. The higher thickness of the CSE Bond was obtained in the concave part of the preparation. The PLF presented a more uniform range of values at different positions. The thickness of Panavia F was higher in the occlusal portion of the preparation. The film thickness formed by CSE Bond and PLF increased the fracture load of the IPS Empress 2 ceramic crown. / A primeira etapa deste estudo avaliou, in vitro, a intera??o entre materiais resinosos utilizados na t?cnica do selamento dentin?rio imediato (SDI) e materiais de moldagens associado a duas t?cnicas para reduzir/eliminar a camada inibida de oxig?nio. A dentina oclusal de 35 terceiros molares humanos foi exposta, seguido de acabamento com lixa de carbeto de sil?cio de granula??o 400. Os dentes foram divididos aleatoriamente em 2 grupos: grupo 1- moldagem com silicone por adi??o Express XT; grupo 2 moldagem com o poli?ter Impregum. Os grupos 1 e 2 foram divididos em 14 subgrupos: grupo 1a e 2a: controle; grupos 1b e 2b: SDI com Clearfil SE Bond (CSE); grupos 1c e 2c: SDI with CSE + polimeriza??o adicional com gel a base de glicerina; grupos 1d e 2d: SDI com CSE + ?lcool; grupos 1e e 2e: SDI com CSE e Protect Liner F (PLF); grupos 1f e 2f: SDI com CSE e PLF + polimeriza??o adicional com gel a base de glicerina; grupos 1g e 2g: SDI com CSE e PLF + ?lcool. Cada superf?cie dent?ria foi fotografada com uma c?mera digital. As imagens foram salvas e utilizadas para avaliar a presen?a de material de moldagem sobre a estrutura dent?ria. Por meio de uma an?lise qualitativa, observou-se que o SDI realizado com o CSE ou com PLF interagiram com o Express XT e com o Impregum. A aplica??o do gel a base de glicerina e do ?lcool impediram a intera??o do CSE com o Express XT e do PLF com o Impregum; no entanto, estes mesmos tratamentos n?o foram totalmente efetivos para o CSE com o Impregum e para o PLF com o Express XT. A segunda etapa deste estudo avaliou a espessura do sistema adesivo, resina de baixa viscosidade e cimento resinoso em preparos para coroas totais, e a influ?ncia na resist?ncia ? fratura de coroa total em cer?mica. Sessenta pr?-molares superiores receberam prepares para coroa total e foram divididos em 3 grupos de acordo com o material aplicado na t?cnica do SDI: grupo 1 controle; grupo 2 - CSE; G3 CSE + PLF. Ap?s moldagem com silicone por adi??o, os preparos receberam provis?rios confeccionados com resina acr?lica. As restaura??es cer?micas com IPS Empress 2 foram confeccionadas e cimentadas sobre os preparos com Panavia F. Dez amostras de cada grupo foram submetidos ao teste de resist?ncia ? fratura e 10 esp?cimes foram seccionados no sentido vest?bulo-lingual para avaliar a espessura do Panavia F, CSE e PLF em 10 posi??es diferentes com o aux?lio de um microsc?pio. De acordo com ANOVA e teste de Tukey, a carga de fratura do grupo 3 (1300 N) foi estatisticamente superior ao grupo 1 (1001 N) (p<0.01) e o grupo 2 (1189 N) n?o apresentou diferen?a estat?stica com os grupos 1 e 3. A maior espessura de pel?cula do CSE Bond foi obtida na parte c?ncava dos prepares. O PLF apresentou a espessura mais uniforme em diferentes posi??es. A espessura do Panavia F foi maior na face oclusal dos preparos. A espessura da pel?cula formada pelo CSE e PLF aumentou a resist?ncia ? fratura de coroas cer?micas confeccionadas com IPS Empress 2.
|
35 |
Degrada??o de condicionadores teciduais em pr?teses totais : estudo in situElsemann, Rog?rio Brasiliense 18 January 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:37Z (GMT). No. of bitstreams: 1
389582.pdf: 4751378 bytes, checksum: 96556d08ded117c5d6139618402559ab (MD5)
Previous issue date: 2007-01-18 / Este estudo in situ avaliou a degrada??o de condicionadores de tecido em fun??o do tempo de uso cl?nico, mensurando a dureza Shore A e a quantidade do agente plastificante ftalato. Tr?s materiais condicionadores de tecido foram avaliados: Coe-Comfort, Dura Conditioner e Softone. Os tr?s materiais foram manipulados de acordo com as instru??es dos fabricantes e inseridos em canaletas (5x15x2 mm) preparadas na regi?o palatal da superf?cie interna de pr?teses totais superiores de nove pacientes da Cl?nica de Pr?tese Total da FO-PUCRS selecionados de acordo com os crit?rios de inclus?o e exclus?o, que permaneceram utilizando suas pr?teses durante o per?odo de avalia??o. As an?lises foram realizadas no baseline, no terceiro, s?timo e d?cimo-quarto dias, ap?s a inser??o dos condicionadores em boca. As mensura??es da dureza foram registradas por meio de um aparelho dur?metro Shore A anal?gico e a quantidade de plastificante foi mensurada por espectrofotometria de infravermelho. Foram selecionadas aleatoriamente esp?cimes dos tr?s condicionadores de cada intervalo de tempo para an?lise em microsc?pio eletr?nico de varredura. Os dados foram analisados por ANOVA utilizando o delineamento em medidas repetidas seguida pelo Teste de Compara??es M?ltiplas de Tukey e por regress?o linear simples, ao n?vel de signific?ncia de 5%. Todos os condicionadores de tecido testados apresentaram redu??o da quantidade de plastificante ftalato e aumento da dureza ao longo do tempo do estudo. O comportamento geral de degrada??o dos condicionadores de tecido testados foi similar mas o padr?o de lixivia??o de ftalato e de aumento de dureza foi espec?fico para cada material. As maiores altera??es de concentra??o de ftalato e de dureza Shore A dos condicionadores de tecido estudados ocorreram nos primeiros tr?s dias de uso cl?nico. Entre o baseline e o dia 3 o Coe- Comfort apresentou redu??o de aproximadamente 25% da concentra??o inicial de ftalato, sendo estatisticamente diferente dos demais materiais que apresentaram perda de 50%. N?o houve altera??o significativa da quantidade de ftalato entre os dias 3 e 7. A quantidade de plastificante no material est? inversamente relacionada com a dureza dos condicionadores de tecido
|
36 |
Avalia??o in vitro da resist?ncia de uni?o ao cisalhamento na colagem de br?quetes por duas fontes de luzMezzomo, Claudia Santos 18 January 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:42Z (GMT). No. of bitstreams: 1
386791.pdf: 7078042 bytes, checksum: 4c1fadb128575046216a3274f924db24 (MD5)
Previous issue date: 2007-01-18 / O objetivo do presente estudo foi comparar, in vitro, a resist?ncia de uni?o ao cisalhamento de br?quetes colados quando expostos ? luz LED e ? luz hal?gena (QTH) mediante diferentes tempos de exposi??o. Para isso 126 dentes pr?-molares foram divididos em seis grupos de acordo com a fonte de luz e o tempo de exposi??o utilizado. Para o conjunto LED, foram usados os tempos de 5, 10 e 15s e para o conjunto QTH, 10, 20, e 30s. Os aparelhos fotopolimerizadoes LED (Ortholux LED Curing Light, 3M-Unitek EUA) e QTH (XL 3000, 3M Unitek EUA) tiveram suas intensidades avaliadas inicialmente e, a cada 10 colagens, por radi?metros espec?ficos para cada natureza de luz, obtendo valores m?dios de 581mW/cm? e 420mW/cm?, respectivamente. Ap?s 24h de estocagem em ?gua destilada a 37?C, os corpos - de - prova foram levados ? m?quina de ensaio mec?nico (Emic DL 2000?) e submetidos ? tens?o de cisalhamento, no sentido c?rvico-oclusal, ? velocidade de 1mm/min. De acordo com os testes estat?sticos ANOVA e Tukey, houve diferen?a significativa entre os grupos estudados (p< 0,01). Os grupos fotoativados por LED 5s (17,20MPa) e 10s (20,54MPa) n?o diferiram entre si, mostrando diferen?a estatisticamente significativa quando comparados ao grupo LED 15s (25,24MPa). Quanto ? fonte luminosa QTH, o grupo de 10s (16,97MPa) diferiu dos 20s (23,61MPa) e 30s (21,33MPa), enquanto esses n?o diferiram entre 8 si. A maior m?dia de resist?ncia de uni?o foi observada no grupo LED 15s, embora este grupo n?o tenha se diferenciado estatisticamente dos grupos QTH 20s e 30s. Verificou-se que at? mesmo os grupos que tiveram as menores m?dias de resist?ncia de uni?o, QTH 10s e LED 5s, respectivamente, apresentaram valores compat?veis com o uso cl?nico. Segundo o teste Kruskal-Wallis, houve diferen?a significativa na distribui??o dos resultados do IAR entre os grupos (p< 0,01). O grupo LED 15s demonstrou padr?o de fratura predominantemente ?ndice 0, sendo observado fratura de esmalte em dois corpos - de - prova. Apesar dos grupos LED 5s e QTH 10s apresentarem maior predom?nio de escores 1 e 2, respectivamente, foram nesses que se observou a maior freq??ncia de escores 3, QTH 10s (10,5%) e LED 5s (9,5%). Comportamento oposto foi observado nos grupos LED 10s e 15s, onde n?o foi registrado freq??ncia de ?ndice 3 (0%). Os achados do presente estudo sugerem que a tecnologia LED (Free Light Ortholux, 3M Unitek) pode ser utilizada, na colagem de br?quetes, com tempos de cura menores em rela??o ? luz hal?gena para a resina Transbond XT, sendo que, o tempo m?nimo de 5s com LED apresentou valor de resist?ncia de uni?o clinicamente aceit?vel.
|
37 |
Estudo experimental para avalia??o da resist?ncia ? compress?o entre dois modelos de fixa??o da osteotomia em L do f?mur proximalUrnauer, Luciano 22 July 2013 (has links)
Made available in DSpace on 2015-04-14T13:35:50Z (GMT). No. of bitstreams: 1
452619.pdf: 1154303 bytes, checksum: 1c5fd674a322085ab06b90525da4401a (MD5)
Previous issue date: 2013-07-22 / Introduction: Coxa brevis is a deformity of the proximal femur caused by a decrease or absence of growth of the physis of the proximal femur, usually caused by avascular necrosis present condition in conditions such as developmental dysplasia of the hip, proximal femoral epiphysiolysis, septic arthritis or disease Legg-Calv?-Perthes disease. Several surgeries have been proposed to lower the greater trochanter and femoral neck lengthening reestablishing the anatomy.
Objective: To compare the mechanical tests by polyurethane in bone models the compressive strength of two different assemblies of plates for fixing osteotomy "L" of the proximal femur.
Material and Methods: We used anatomical models of the proximal femur polyurethane which underwent an osteotomy longitudinal and divided into two groups with one group fixed with 4.5 DCP plate 10 holes with four screws proximal and three distal screws and fixed with a group 4.5 DCP plate 6 holes with two proximal and two distal screws. The anatomical models were tested for flexo in mechanical universal testing machine and was evaluated relative stiffness and linear movement.
Results: By comparing the two groups in flexo tests, the average value of the relative stiffness in group 1 set with the long plate was 386.17 x10-3 N / m. In the group with the smaller plate fixed average value of the relative stiffness was 261,89 x10-3 N / m. The average linear displacement observed for an applied force of 1000 N in group 1 was 2.53 x10-3. In group 2, the mean value of linear displacement was 3.49 x 10-3m.
Conclusion: Based on the parameters measured in the tests flexo, stability obtained by fixing the first group with a plate of ten holes was significantly higher than that obtained by fixing the second group with six holes of the plate. / Introdu??o: Coxa brevis ? uma deformidade do f?mur proximal causada pela diminui??o ou aus?ncia de crescimento da fise da extremidade proximal do f?mur, geralmente causada por necrose avascular condi??o presente nas patologias como displasia do desenvolvimento do quadril, epifisi?lise femoral proximal, artrite s?ptica ou doen?a de Legg-Calv?-Perthes. Diversas cirurgias tem sido propostas para rebaixar o grande troc?nter ou alongar o colo femoral reestabelecendo a anatomia. Objetivo: comparar atrav?s de testes mec?nicos em modelos ?sseos de poliuretano a resist?ncia ? compress?o entre duas montagens diferentes de placas para fixa??o osteotomia em L do f?mur proximal. Material e M?todos: Foram utilizados modelos anat?micos de f?mur proximal em poliuretano no qual foi realizado uma osteotomia longitudinal e divididos em dois grupos sendo um grupo fixado com placa 4,5 DCP 10 furos com quatro parafusos proximais e tr?s parafusos distais e um grupo fixado com placa 4,5 DCP 6 furos com dois parafusos proximais e dois distais. O modelos anat?micos foram submetidos a teste de flexocompress?o em m?quina universal de ensaios mec?nicos e foi avaliado a rigidez relativa e o deslocamento linear. Resultados: Ao comparar os dois grupos nos ensaios de flexocompress?o, o valor m?dio da rigidez relativa no grupo 1 fixado com a placa longa foi de 386,17 x10-3 N/m. No grupo fixado com a placa menor o valor m?dio da rigidez relativa foi de 261,89 x10-3 N/m. O valor m?dio do deslocamento linear, observado para uma for?a aplicada de 1000 N, no grupo 1 foi de 2,53 x10-3. No grupo 2 o valor m?dio do deslocamento linear foi de 3,49 x10-3m. Conclus?o: Com base nos par?metros analisados nos ensaios de flexocompress?o, a estabilidade obtida pela fixa??o do grupo 1 com placa de dez furos foi significativamente maior que a obtida pela fixa??o no grupo 2 com a placa de seis furos.
|
38 |
Avalia??o da resist?ncia de uni?o de adesivos universais ? dentinaCosta, Daniele Morosini 29 February 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-06-30T17:18:27Z
No. of bitstreams: 1
DIS_DANIELE_MOROSINI_COSTA_PARCIAL.pdf: 515880 bytes, checksum: 055ee81e963cb874c2263912d41a40f6 (MD5) / Made available in DSpace on 2016-06-30T17:18:27Z (GMT). No. of bitstreams: 1
DIS_DANIELE_MOROSINI_COSTA_PARCIAL.pdf: 515880 bytes, checksum: 055ee81e963cb874c2263912d41a40f6 (MD5)
Previous issue date: 2016-02-29 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The aim of this study was to evaluate, in vitro, the tensile bond strength to dentin of the adhesive systems Single Bond Universal (3M), All-Bond Universal (Bisco) and One Coat 7 (Colt?ne), in the self-etch mode, taking Clearfil SE Bond as control. The middle portion of 120 bovine teeth were included in a selfcured acrylic resin and abraded in a mechanic lathe with water refrigeration in order to obtain a plane surface in dentin. The adhesives systems were applied on the dentin in accordance with the instructions of the manufacturers, followed by the application of composite resin Z250 (3M). Thirty specimens were obtained for each adhesive system. After immersion in distilled water at 37 oC for 24 hours, half of the specimens were submitted to cyclic loading using 500,000 cycles. For all specimens, the tensile bond strength was determinated in a universal testing machine (EMIC DL-2000) at a cross-head speed of 0.5 mm/minute. The results were analyzed by two-way ANOVA and Tukey?s test (? = 5%). The interaction between the factors adhesive system and cyclic loading was significant (p<0.05). The means followed by the same letter represent no statistical difference for the tensile bond strength (MPa) after 24 h: One Coat 7 = 7.86A (?2.90), Single Bond Universal = 6.78AB (?2.03), All-Bond Universal = 5.61BC (?2.32), Clearfil SE Bond = 3.53C (?1.89). After cyclic loading, the adhesive systems Clearfil SE Bond, Single Bond Universal and All-Bond Universal maintained the bond strength values comparable to 24 h period. There was a significant decrease only for One Coat 7. The adhesive system Single Bond Universal, All-Bond Universal and One Coat 7, in the self-etch mode, had bond strength to dentin comparable to Clearfil SE Bond. Only the adhesive system One Coat 7 decreased the bond strength to dentin after cyclic loading. / O objetivo deste trabalho foi avaliar, in vitro, a resist?ncia de uni?o ? tra??o sobre a dentina dos sistemas adesivos universais Single Bond Universal (3M), All-Bond Universal (Bisco) e One Coat 7 (Colt?ne), na vers?o autocondicionante, tendo o Clearfil SE Bond como controle. O ter?o m?dio da coroa de 120 dentes incisivos bovinos foi inclu?do em resina acr?lica autopolimeriz?vel e desgastado em um torno mec?nico sob refrigera??o ? ?gua para obter uma superf?cie plana em dentina. Os sistemas adesivos foram aplicados sobre a dentina de acordo com as instru??es dos fabricantes, seguido da aplica??o de resina composta Z250 (3M). Trinta corpos de prova foram confeccionados para cada sistema adesivo. Ap?s armazenagem em ?gua destilada a 37? C por 24 h, metade dos corpos de prova de cada grupo foi submetida ? 500.000 ciclos de ciclagem mec?nica. Todos os corpos de prova foram submetidos ao teste de resist?ncia de uni?o ? tra??o na m?quina de ensaio universal EMIC DL-2000 com velocidade de 0,5 mm/minuto. Os resultados foram analisados pela ANOVA de duas vias e o teste de Tukey (? =5%). Houve intera??o entre os fatores sistema adesivo e ciclagem mec?nica (p<0,05). As m?dias seguidas de mesma letra n?o diferem estatisticamente para a resist?ncia de uni?o (MPa) medida ap?s 24 h: One Coat 7 = 7,86? (?2,90), Single Bond Universal = 6,78AB (?2,03), All-Bond Universal = 5,61BC (?2,32), Clearfil SE Bond = 3,53C (?1,89). Ap?s ciclagem mec?nica, os sistemas adesivos Clearfil SE Bond, Single Bond Universal e All-Bond Universal mantiveram os valores de resist?ncia de uni?o compar?veis ao per?odo de 24 h, havendo redu??o significativa para o One Coat 7. Os sistemas adesivos Single Bond Universal, All-Bond Universal e One Coat 7, na vers?o autocondicionante, tiveram resist?ncia de uni?o ? dentina compar?vel ao sistema adesivo Clearfil SE Bond. Apenas o sistema adesivo One Coat 7 apresentou redu??o na resist?ncia de uni?o ? dentina ap?s ciclagem mec?nica.
|
39 |
Efeito da usinagem e de procedimentos p?s-usinagem na superf?cie de materiais odontol?gicos para CAD/CAMNunes, Laura Smidt 08 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-07-14T16:57:14Z
No. of bitstreams: 1
DIS_LAURA_SMIDT_NUNES_PARCIAL.pdf: 228259 bytes, checksum: 74df0dbd4064a00e8b0071f07e6d7ecf (MD5) / Made available in DSpace on 2016-07-14T16:57:14Z (GMT). No. of bitstreams: 1
DIS_LAURA_SMIDT_NUNES_PARCIAL.pdf: 228259 bytes, checksum: 74df0dbd4064a00e8b0071f07e6d7ecf (MD5)
Previous issue date: 2016-03-08 / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / The aim of the study was to evaluate the surface roughness and analyze the surface topography of five different ceramics, a resin composite and two polymers for CAD/CAM after milling and post milling procedures. Blocks of Mark II, IPS Empress CAD, IPS e.max CAD, Enamic, Lava Ultimate, Suprinity, CAD-Temp and CAD-Waxx were milled in CEREC MCXL system. The surface roughness (Ra; ?m) was measured before and after millig procedures, polishing and glaze (when indicated) followed by analysis by SEM and AFM. The results were subjected to statistical tests (one-way ANOVA for repeated measures and Tukey HSD and one-way ANOVA also with Post-Hoc Tukey, respectively) with a significance level of 5% (?=0.05). The milling step significantly increased surface roughness in all tested materials (p<0.05). Mechanical polishing was able to reduce the roughness generated by grinding, requiring the glazing step only in partially crystallized ceramic (IPS e.max CAD and Suprinity). In other materials (Mark II, IPS Empress CAD, Lava Ultimate, Enamic, CAD- Temp and CAD-Waxx) mechanical polishing was enough to achieve similar surface roughness values of the smoothness of the blocks directly from manufacturers. The study suggests that the glaze step can be suppressed in materials completely crystallized and/or polymerized by the manufacturer, these having no statistically significant difference when it's just done mechanical polishing. / O objetivo do estudo foi avaliar a rugosidade superficial e analisar a topografia de superf?cie de cinco diferentes cer?micas, um comp?sito resinoso e dois acr?licos para CAD/CAM ap?s usinagem e procedimentos p?s-usinagem. Blocos de Mark II, IPS Empress CAD, IPS e.max CAD, Enamic, Lava Ultimate, Suprinity, CAD-Temp e CAD- Waxx foram usinados no sistema CEREC MCXL. A rugosidade superficial (Ra; ?m) foi aferida antes e ap?s os procedimentos de usinagem, polimento e glaze (quando indicado) seguidos de an?lises em MEV e MFA. Os resultados foram submetidos a testes estat?sticos (teste one-way ANOVA para medidas repetidas e Tukey HSD e ANOVA one-way tamb?m com Post-Hoc Tukey, respectivamente) com n?vel de signific?ncia de 5% (?=0,05). A etapa de fresagem aumentou significativamente a rugosidade superficial em todos os materiais testados (p<0,05). O polimento foi capaz de reduzir a rugosidade gerada pela usinagem, sendo necess?ria a etapa de glazeamento apenas para cer?micas parcialmente cristalizadas (IPS e.max CAD e Suprinity). Nos demais materiais (Mark II, IPS Empress CAD, Lava Ultimate, Enamic, CAD-Temp e CAD-Waxx) o polimento mec?nico foi suficiente para atingir valores de rugosidade superficial similares a lisura dos blocos provenientes diretamente dos fabricantes. O estudo sugere que a etapa de glaze pode ser suprimida nos materiais j? provenientes do fabricante completamente cristalizados e/ou polimerizados, nestes n?o possuindo diferen?a estatisticamente significativa quando apenas ? realizado polimento mec?nico.
|
40 |
Influ?ncia do tempo de condicionamento e concentra??o do ?cido fluor?drico na resist?ncia de uni?o de um sistema adesivo ? superf?cie de cer?micas para CAD/CAMCosta, Helo?sa 29 February 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-08-01T16:58:26Z
No. of bitstreams: 1
DIS_HELOISA_COSTA_PARCIAL.pdf: 121948 bytes, checksum: b60caab299692040c6bbd09f4274ab38 (MD5) / Made available in DSpace on 2016-08-01T16:58:26Z (GMT). No. of bitstreams: 1
DIS_HELOISA_COSTA_PARCIAL.pdf: 121948 bytes, checksum: b60caab299692040c6bbd09f4274ab38 (MD5)
Previous issue date: 2016-02-29 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Aims: to evaluate the microtensile bond strength of an adhesive (Signum Ceramic Bond (Heraeus / Kulzer) made for repairing fractured CAD/CAM ceramics after different surface treatments. Materials and Methods: Three different types of ceramic blocks for CAD / CAM were used: Mark II, Empress CAD and e.max CAD. The ceramics were divided into four subgroups according to the following surface treatment: G1: roughening with specific drill (ASP, Signum) + adhesive system; G2: hydrofluoric acid (HF) 5% + Signum, G3: ASP + 5% + AF Signum, G4: ASP + AF 10% + Signum. After the adhesive system application, a 6.0 mm resin composite block (Charisma) was made for the microtensile test. After 15 days of storage in distilled water, the blocks were cut and selected 20 sticks with cross sectional area of 1.0 mm2. The specimens were submitted to microtensile in a universal testing machine. Results: The use of ASP + AF 10% promoted the highest bond strength values in the ceramic Mark II (23.08 MPa) and Empress CAD (29.36 MPa). In e.max CAD, the use of ASP + AF 5% led to the highest values of bond strength (25.19 MPa). Based on these results we conclude that the adhesion of the adhesive system Signum for ceramics repairing depends on surface treatment being the association abrasion + hydrofluoric acid the most suitable. / Objetivos: Esse estudo teve por objetivo avaliar, in vitro, a influ?ncia do tratamento de superf?cie de cer?micas para CAD/CAM na resist?ncia de uni?o do adesivo Signum Ceramic Bond (Heraeus/Kulzer) utilizado para reparo de cer?micas fraturadas. Materiais e M?todos: tr?s diferentes tipos de blocos de cer?mica para CAD/CAM foram utilizados: Mark II, Empress CAD e e.Max CAD. As cer?micas foram divididas em 4 subgrupos de acordo com o tratamento de superf?cie empregado: G1: asperiza??o com broca espec?fica (ASP, Signum) + sistema adesivo; G2: ?cido fluor?drico (AF) 5% + Signum, G3: ASP + AF 5% + Signum, G4: ASP + AF 10% + Signum. Ap?s a aplica??o do sistema adesivo, um bloco de resina composta (Charisma) foi confeccionado para o ensaio de microtra??o. Ap?s 15 dias de armazenamento em ?gua destilada, os blocos foram seccionados e selecionados 20 palitos com ?rea adesiva de aproximadamente 1,0 mm2. Os corpos de prova foram submetidos ao ensaio de microtra??o em uma m?quina de ensaios universal. Resultados: O uso da ASP + AF 10% promoveu os maiores valores de resist?ncia adesiva nas cer?micas Mark II (23,08 MPa) e Empress CAD (29,36 MPa). No e.max CAD, o uso da ASP + AF 5% propiciou os maiores valores de resist?ncia adesiva (25,19 MPa). Com base nos resultados encontrados ? poss?vel concluir que a ades?o do sistema adesivo Signum para reparo de cer?micas para CAD/CAM depende do tratamento de superf?cie empregado sendo que a associa??o abras?o + ?cido fluor?drico ? a mais indicada.
|
Page generated in 0.1123 seconds