• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 308
  • 11
  • 11
  • 11
  • 11
  • 9
  • 2
  • 1
  • 1
  • Tagged with
  • 313
  • 313
  • 188
  • 184
  • 86
  • 81
  • 74
  • 74
  • 61
  • 53
  • 50
  • 41
  • 38
  • 36
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Resistência à remoção por tração de coroas NiCr cimentadas sobre munhões usinados em liga de titânio, irradiados ou não por LASER / Tensile strenght of NiCr crowns cemented upon usinated titanium alloy abutments, LASER irradiated or not

Toledo, Fabiane Lopes 24 May 2007 (has links)
No presente trabalho, usando ensaios de remoção por tração, o objetivo foi avaliar a eficiência de 4 agentes (fosfato de zinco S. S.White, ionômero de vidro Ketac Cem Easymix, resina composta RelayX Luting 2 e resina acrílica especial Panavia 21 TC) usados para fixar coroas totais de NiCr a munhões tronco-cônicos, usinados em liga de Ti-6Al-4V. Dentre os cinqüenta munhões utilizados, 40 permaneceram com sua superfície original altamente lisa (como vieram de fábrica) e foram distribuídos em grupos de 10, para cada agente cimentante; no grupo dos 10 restantes existiu uma modificação por irradiação com LASER e cimentação apenas com fosfato. Os ensaios mecânicos foram realizados em uma máquina universal MTS 810, na velocidade de 0,5 mm/min. A respectiva Análise de Variância (ANOVA) apontou existir diferença significante entre os grupos e o teste de Tukey (p<0,05) também mostrou diferenças significantes entre eles, exceto nas comparações original/fosfato versus original/RelayX e original/fosfato versus original/KetcCem. Para os munhões não-irradiados, o melhor desempenho foi apresentado pela resina Panavia 21 (1.127,996 N); a resina composta RelyX (478,197 N) mostrou comportamento similar apenas ao do fosfato (430,662 N), o qual apresentou desempenho semelhante ao ionômero de vidro KetacCem (227,705 N). A modificação da superfície do munhão fez com que a magnitude da resistência à tração das coroas cimentadas com fosfato aumentasse para 1.514,872 N. / By means of tensile essays, NiCr total crowns were removed from usinated tronco-conical abutments composed by an Ti-6Al-4V alloy; the performance of 4 cementig agents (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelayX Luting 2 composite resin and Panavia 21 TC special acrylic resin) was evaluated. Among a total of 50 abutments, 40 were used with it surface presenting high smoothness (as they come from manufacturer) and distributed in groups of 10 elements, each group for each cementing agent; the other 10 abutments had had its surfaces modified by LASER and were used only with phosphate. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukey´s test (p<0.05) also detected significant differences, except at comparisons of original/phosphate versus original/ RelayX and original/phosphate versus original/ KetacCem. To non-irradiated abutments, the better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of KetacCem (227.705 N). The referred LASER irradiation promoted an increased resistance to the phosfate, which reached 1,514.872 N.
42

Estudo do comportamento das fibras de carbono do tipo I e tipo II em tração simples e tração em nó

José Luis Gomes da Silva 01 December 1991 (has links)
O objetivo deste trabalho foi o de estudar o comportamento da resistência à tração em função do tamanho do corpo de prova e do equacionamento da força axial de tracionamento, quando um monofilamento é submetido a um Nó, para f ibras de carbono obtidas a partir da fibra poliacrilonitrila (PAN). As estimativas estatísticas da resistência à tração em função da presença de defeitos na superfície das fibras de carbono, permitiram otimizar o tamanho do corpo de prova onde a pouca ou quase nenhuma população de defeitos residentes na superfície ao longo do comprimento da fibra, geraram valores de resistência à tração consistentes em corpos de prova com comprimentos não superiores a 2,5cm. Para corpos de prova com tamanhos abaixo de O,lmm, os testes de Nó forneceram valores efetivos da resistência e módulo de elasticidade em flexão, tanto para fibras de carbono de alto módulo de elasticidade, como para fibras de aI ta resistência à tração. Isto foi enfatizado devido à estimativa ser altamente dependente de anomalias na superfície quando a fibra sofreu deformação de flexão e tração. A uniformidade do módulo de elasticidade, e principalmente do diâmetro das fibras, foram preponderantes nos cálculos teóricos e nos valores experimentais quando o XI monofilamento foi submetido a cargas de tracionamento em Nó. OS valores encontrados para a carga axial tanto em fibras de alto módulo de elasticidade, como em fibras de alta resistência à tração, demonstraram que as variações no diâmetro ao redor de 10% foram representativas.As fraturas que ocorreram quando o monof ilamento foi submetido à tração simples, bem como à tração em &quot;Nó&quot;, apresentaram características de fraturas típicas de tração e flexão em fibras de carbono. Essas fraturas foram estudadas e analisadas através de microscópio eletrônico de varredura, onde se pode dectetar visíveis diferenças entre elas.
43

Resistência de união à dentina de sistemas adesivos irradiados com laser de diodo: estudo in vitro / Bond strength to dentin with adhesive systems irradiated with diode laser: in vitro study

Maenosono, Rafael Massunari 26 March 2013 (has links)
A irradiação LASER sobre os sistemas adesivos aplicados em dentina, antes de sua fotoativação, tem sido proposta para aumentar a resistência de união de restaurações adesivas. O objetivo foi avaliar o efeito da irradiação com LASER de Diodo (&#x3BB; = 970nm) sobre diferentes sistemas adesivos na resistência de união imediata à dentina. Oitenta molares humanos hígidos foram aleatoriamente distribuídos em 8 grupos (n=10) de acordo com o sistema adesivo: MP (Adper&#x2122; ScotchBond Multi-Purpose Plus - convencional não simplificado), SB (Adper&#x2122; SingleBond 2 - convencional simplificado), CSE (Clearfil&#x2122; SE Bond - autocondicionante não simplificado), EO (Adper&#x2122; EasyOne - autocondicionante simplificado); e respectivos grupos irradiados com LASER de Diodo (SiroLaser, Sirona Dental). Para avaliar a resistência de união foi realizado teste de microtração, obtendo-se valores em MPa, posteriormente analisados através de ANOVA a 2 critérios, seguido de Tukey para comparações individuais e múltiplos testes t (p<0,05) para comparações entre CONTROLE e LASER do mesmo sistema adesivo. Os valores de resistência de união ± desvio padrão para os grupos sem e com irradiação com LASER foram respectivamente: MP (40,10±10,95 / 35,82±7,17), SB (33,49±6,77 / 43,69±8,15), CSE (43,71±15,71 / 37,95±7,66) e EO (19,67±5,86 / 29,87±6,98). A irradiação com LASER de Diodo provocou um aumento da resistência de união obtida pelos sistemas adesivos SB e EO, mostrando-se uma técnica promissora na obtenção de uma adesão mais efetiva de sistemas adesivos simplificados ao substrato dentinário. / LASER irradiation on adhesive systems before it`s activation has been proposed to increase bond strength of composite restorations to dentin. The objective was to evaluate the effect of Diode LASER irradiation (&#x3BB; = 970nm) on different adhesive systems on immediate bond strength to dentin. Eighty healthy human molars were randomly distributed in 8 groups (n=10) according to the adhesive system: MP (Adper&#x2122; ScotchBond Multi-Purpose Plus, non simplified etch and rinse), SB (Adper&#x2122; SingleBond 2 simplified etch and rinse), CSE (Clearfil&#x2122;SE Bond non simplified self-etch), EO (Adper&#x2122; EasyOne simplified self-etch); and respective groups irradiated with Diode LASER (SiroLaser, Sirona Dental). Microtensile test was performed obtaining bond strength values in MPa whice were analyzed by two way ANOVA, followed by Tukey for individual comparisons and multiple t test (p<0.05) for evaluation of CONTROL and LASER groups with the same adhesive systems. Bond strength values ± standard deviation for groups without and with LASER irradiation were respectively: MP (40.10±10.95 / 35.82±7.17), SB (33.49±6.77 / 43.69±8.15), CSE (43.71±15.71 / 37.95±7.66) and EO (19.67±5.86 / 29.87±6.98). Irradiation with Diode LASER resulted in an increase of SB and EO bond strength values, being considered a promising technic to obtain an improved adhesion of simplified adhesive systems to dentin substrate.
44

Efeito da variação da densidade de energia da ponta e da frequência na resistência de união à dentina de sistema adesivo convencional irradiado com diferentes laseres de alta potência / Variation of the effect of the energy density of the fiber tip and frequency in bond strength to irradiated conventional dentin bonding system with different high-power LASERs

Cardia, Guilherme Saintive 15 September 2015 (has links)
O objetivo deste estudo foi comparar o efeito da irradiação de dois tipos de laser (laser Nd:YAG e de Diodo) sobre um sistema adesivo convencional de três passos, utilizando três diferentes densidades de energia da ponta, na resistência de união imediata e após 1 ano. Foram selecionados 70 dentes humanos e cada um teve sua coroa seccionada, expondo a superfície da dentina necessária para os procedimentos adesivos e restauradores. Após o preparo dos dentes, os mesmos foram aleatoriamente subdivididos em 7 grupos (n=10), sendo 6 grupos-teste e um grupo controle. Na sequência, foi aplicado o sistema adesivo Scotchbond&#x2122; Multi- Purpose Plus e, antes de sua fotoativação, em três grupos, o laser Nd:YAG foi utilizado com 3 diferentes densidades de energia (1 509,55 J/cm2, 2 254,77 J/cm2 e 3 127,38 J/cm2), o mesmo procedimento com as mesmas densidades foi realizado nos três demais grupos com o laser de Diodo. Após a irradiação seguida da fotoativação, os dentes foram restaurados com incrementos de resina composta Filtek&#x2122; Z250. Os dentes restaurados foram então imersos em água deionizada e mantidos em estufa a 37oC por um período de 7 dias. Após o armazenamento, os espécimes foram seccionados de modo que se obtivessem palitos com área transversal de aproximadamente 1mm2. De forma aleatória, estes palitos foram separados em 2 grupos: o primeiro submetido imediatamente a testes de microtração em uma máquina de ensaio universal INSTRON 3342 e segundo submetido ao mesmo processo após 1 ano de armazenamento. Os valores de resistência de união foram submetidos aos testes ANOVA e post hoc de Tukey, para que comparações individuais pudessem ser realizadas. Não houve diferença estatisticamente significante entre os lasers utilizados. Os grupos irradiados com ambos os lasers apresentaram resultados similares ao grupo controle, com exceção ao grupo que utilizou o laser de Diodo com menor densidade de energia da (GD3), no qual o resultado foi inferior ao grupo controle no momento imediato. Quedas significativas nos valores de resistência de união foram observadas, com exceção aos grupos que utilizaram o laser de Diodo (GD3 GD2) e o laser Nd:YAG (GNd3). Os diferentes lasers não apresentaram diferença entre si e não foram capazes de promover aumento na resistência e união imediata comparados ao grupo controle. Todos os grupos obtiveram quedas na resistência de união, mesmo em alguns grupos esta queda não sendo significativa. Alterações de alguns parâmetros ou até mesmo a utilização de outro tipo de LASER poderiam ajudar a definir o protocolo ideal para o uso efetivo deste sistema de tratamento adjunto. / The aim of this work was to compare the effect of the irradiation of two types of laser (Nd:YAG and diode laser) on a conventional three-step adhesive system, using three different energy densities of the fiber tip in bond strength immediately and after 1 year. 70 human teeth were selected, and each one had the crown sectioned, exposing the dentin surface for the adhesive and restorative procedures. After teeth preparation, they were randomly divided into 7 groups (n = 10), being 6 test-groups and one control group. Thus, the bonding system Scotchbond&#x2122; Multi-Purpose Plus was applied, and before light cured, the Nd:YAG laser was used in three groups, with three different energy densities of the fiber tip (1 - 509.55 J/cm2, 2 - 254.77 J/cm2 and 3 - 127.38 J/cm2), the same procedures with the same energy densities of the fiber tip were performed for the diode laser. After irradiation followed by light cured, the teeth were restored with composite resin increments (Filtek&#x2122; Z250). The restored teeth were immersed in deionized water and maintained in oven at 37oC for 7 days. After storage, the specimens were sectioned in order to obtain sticks with crosssectional area of approximately 1mm2. Randomly, these sticks were divided into 2 groups: the first one was submitted immediately to microtensile tests in a universal testing machine INSTRON 3342, and the second group was submitted to the same procedure after one year of storage. The bond strength values were submitted to ANOVA and Tukey post hoc tests for individual comparisons. There was no statistically significant difference between the laser s. Irradiated groups showed similar results to the control group, except for the group that used the diode laser with lower energy density of the fiber tip (GD3), in which the results were lower than the control group in the immediate moment. Significant reduction in the values of bond strength were observed, except for the groups that used the diode laser (GD3 - GD2), and the Nd:YAG laser (GNd3). Different lasers did not differ among themselves and were not able to promote an increase in resistance and immediate union compared to the control group. All groups had declines in bond strength, even in some this fall not significant groups. Changes in some parameters or even the use of another type of laser could help define the optimal protocol for the effective use of this adjunctive treatment system.
45

Desenvolvimento e validação de um novo protocolo para ciclagem térmica de materiais dentários /

Marinho, Caroline Cotes. January 2015 (has links)
Orientador: Estevão Tomomitsu Kimpara / Co-orientador: Fabíola Pessoa Pereira Leite / Banca: Vanessa da Cruz Macedo / Banca: Sérgio Eduardo de Paiva Gonçalves / Banca: Flávia Zardo Trindade / Banca: Josete Barbosa Cruz Meira / Resumo: Este trabalho teve como objetivos: avaliar a variação térmica que ocorre em ambiente bucal para predizer a quantidade e duração das variações de temperatura por dia, a temperatura máxima e mínima encontrada na cavidade oral e sugerir um novo protocolo de ciclagem térmica baseado nestas informações; e comparar os resultados de resistência de união após várias formas de envelhecimento. Para tal, foi instalado um sensor térmico wireless no palato de um aparelho parcial removível de seis voluntários, e estes foram monitorados durante três dias para desenvolvimento de um novo protocolo de ciclagem térmica. Após esta etapa, 40 blocos de cerâmica feldspática foram cimentados entre si (N=20), divididos em cinco grupos (n=4) e cortados em fatias. As fatias foram submetidas aos seguintes tipos de envelhecimento: C, teste imediato (sem envelhecimento); A, armazenagem em água por 30 dias; E, protocolo de ciclagem térmica experimental desenvolvido neste estudo; CIB, ciclagem intra-bucal; e ISO, protocolo de ciclagem térmica estabelecido pela norma ISO 11405 (2003). As fatias foram cortadas em palitos, os quais foram submetidos ao teste de microtração. A análise de falha foi realizada com o auxílio de um estereomicroscópio. A temperatura máxima encontrada foi de 47,59 ̊C, a mínima foi de 13,11 ̊C. A média de temperatura diária manteve-se entre 34 ̊C e 36 ̊C. A média de variação de temperatura por dia foi de 5,3 vezes, com duração média de 183 s. Os grupos A, CIB, E apresentaram valores de resistência de união estatisticamente menor que o grupo C (p-valor=0,0002), sendo semelhantes entre si. O grupo ISO foi semelhante aos grupos C e CIB. O modo de falha mais encontrado para todos os grupos foi do tipo mista. Conclui-se que ocorrem em média 6 variações térmicas por dia, com duração de 180 segundos. O protocolo de ciclagem térmica sugerido pela ISO não foi capaz de reduzir a resistência de uniâo. A ciclagem.. / Abstract: This study aimed to evaluate the thermal variation that occurs in the oral environment; predicted the number of thermal cycles and temperature variation which occurs during certain time periods and compared the results of the bond strength of ceramic and luting agent after different aging protocols. For this purpose, six volunteers used a removable device with wireless thermal sensor and they were monitored for three days, to develop a new thermal cycling protocol. After this step, 40 feldspathic ceramic blocks were cemented together with a resin luting agent (N = 20), divided into five groups (n = 4) and cut into slices. Aging of the slices were: C, immediate test (without aging); A, storage in water for 30 days; E, thermal cycling experimental protocol developed in this study; CIB, storage of the slices in mouth for 30 days; and ISO, thermal cycling protocol established by ISO 11405 (2003). The slices were cut into sticks for microtensile test. The failure analysis were performed in a stereomicroscope. Maximum temperature observed was 47.59 ̊C, the lowest temperature was 13.11 ̊C. The average daily temperature is between 34 ̊C and 36 ̊C. The average temperature change per day was 5.3 times, with an average duration of 183 s. A, CIB, and E groups showed strength values statistically lower than C group (p-value = 0.0002), and they were similar among them. The ISO group was similar to the groups C and IB. The failure type most commonly found for all groups was mixed mode. It concluded that occurs daily 6 temperature variations, with duration of 180 seconds. The ISO thermocycling protocol did not reduce the bond strength. The experimental cycling used in E, 180 thermal cycles with a temperature range of 50 ̊C and 10 ̊C for 180 seconds each and 36 ̊C intermediate baths was able to accelerate the degradation process of bond between ceramic and cement that occurred during storage in water for 30 days / Doutor
46

Efeito de diferentes tipos de soldagem na resistência à tração de estruturas fundidas com ligas de Ni-Cr / Effects of different types of welding on the tensile strenght of NI-Cr structures

Mansano, Romão Adalberto de Souza 21 May 2007 (has links)
A confecção de infra-estruturas metálicas em reabilitações orais, envolvem processos criteriosos principalmente no que concerne ao processo de fundição e soldagem das mesmas. O objetivo deste trabalho foi avaliar a resistência à tração de peças fundidas em monobloco com três diferentes métodos de soldagem: solda convencional (maçarico), solda a laser e solda TIG (tungstênio Inerte Gás). Oitenta padrões de plástico pré-fabricados (vinte para cada grupo) foram fundidos em liga de Ni-Cr, sendo o grupo controle (monobloco) unido previamente à fundição. Após, os corpos-de-prova do grupo teste foram divididos aleatoriamente para posterior soldagem e teste de resistência, realizado em uma máquina de ensaios mecânicos (Kratos). Os resultados médios (MPa) foram: monobloco 784,08, solda laser 588,42, solda convencional 366,80 e solda TIG 319,78. Os dados foram submetidos á analise estatística ANOVA e teste de Tukey (p,0,05), sendo que o grupo controle (monobloco) apresentou valores de resistência estatisticamente superior a todos os do grupo teste. Entre as peças soldadas, a solda laser apresentou valores de resistência estatisticamente superior em relação aos grupos (convencional e TIG), os quais não diferiram estatisticamente entre si. Concluí-se que apesar de ter havido diferenças estatísticas entre os grupos, os três métodos de soldagem podem ser indicadas pelos resultados altamente satisfatórios. / The development of metallic prosthetic framework in oral rehabilitation, involves critical processes specially related to casting and welding. The objective of this work was to evaluate the tensile strength of cast plates (monobloc) with three different welding methods: conventional welding (torch), laser welding and TIG welding (tungsten inert gas). Eighty pre fabricated plastic patterns (twenty for each group), were welded in Ni-Cr alloy, being the control group (monobloc) jointed previously to welding. The specimens of the test group were randomly divided for posterior welding and tensile strength test, which were performed in an universal testing machine (Kratos). The mean values (Mpa) were: monobloc (control) - 785.08, laser welding - 588.42, conventional welding - 366.80 and TIG 319.78. Data were analyzed by One-way ANOVA and Tukey test (p.0.05). The control group (monobloc) presented tensile strength values statistically superior compared to all test groups. Between the welded patterns, the laser welding presented tensile strength values statistically superior compared to the other welding groups (conventional and TIG), which did not show any statistically difference between them. Therefore, it can be concluded that despite of the statistical difference between the groups, the three welding methods can be indicated by the highly satisfactory results.
47

Contribuição do glutaraldeído como componente de sistemas adesivos dentinários / Influence of glutaraldehyde priming on bond strengths of an experimental adhesive system applied to wet and dry dentin

Cilli, Renato 10 August 2007 (has links)
Neste trabalho foram testadas as seguintes hipóteses nulas: 1) Não há diferença entre os valores de resistência de união entre resina restauradora e dentina quando uma solução aquosa de glutaraldeído é aplicada como primer dentinário antes do emprego do agente adesivo; 2) Não há diferença entre os valores de resistência de união, quando a aplicação do mesmo sistema adesivo se dá em condições de dentina úmida ou seca. Dentes humanos foram selecionados, e tiveram sua porção oclusal desgastada, expondo a parte média da dentina coronária para adesão. Quatro grupos foram formados, variando-se a aplicação ou não do primer de glutaraldeído e a condição de umidade dentinária: úmida ou seca. Após aplicação e fotopolimerização do sistema adesivo experimental, foram confeccionados blocos resina composta de 4mm de altura sobre a superfície oclusal e os dentes foram preparados para o teste de microtração para a avaliação da resistência de união. Os resultados obtidos foram submetidos à análise de variância a um critério e teste de Tukey (\'alfa\'\'=0,05). A aplicação do primer de glutaraldeído aumentou significativamente os resultados de resistência de união. Não houve diferença estatística entre o mesmo sistema experimental se aplicado em dentina seca ou úmida. A hipótese 1 não se confirma e aceita-se a hipótese 2. / This work tested the following null hypothesis: 1) There is no difference between resin-dentin bond strengths when a glutaraldehyde primer solution is applied onto demineralized dentin during adhesive bonding. 2) There is no difference between resin-dentin bond strengths when the same experimental adhesives systems are applied whether in dry or wet demineralized dentin conditions. Human, extracted upper third molars were selected. The oclusal surfaces were ground flat, and midcoronal dentin was exposed for bonding. Four groups of six teeth were formed. Two groups were designated for dry dentin technique and two for the wet one. After application and photopolymerization of the bonding system, a 4 mm-high resin core build-up was fabricated over the adhesive layer. Specimens were then prepared for microtensile bond test for bond strengths evaluation. The obtained data were submitted to ANOVA and Tukey test (\'alpha\'=0.05). Glutaraldehyde primer application significantly improved resin-dentin bond strength. No significant difference was observed when the same experimental adhesive system was applied whether in dry or wet dentin conditions. Such results require to reject the first null hypothesis and accept the second one.
48

Degradação quimica da união de materiais adesivos ao substrato dentinario : analise mecanica e micromorfologica / Chemical degradation of adhesive materials bonded to dentin substrate : mechanical and micromorphologic analysis

Correr, Ana Rosa Costa, 1977- 05 October 2018 (has links)
Orientador: Regina Maria Puppin-Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-10-05T18:32:34Z (GMT). No. of bitstreams: 1 Costa_AnaRosa_M.pdf: 3213917 bytes, checksum: 992b632a45094f40763749a7a2048776 (MD5) Previous issue date: 2009 / Resumo: O propósito neste estudo foi avaliar o efeito da ciclagem dinâmica de pH (solução DES/RE) e o tempo de armazenagem na degradação da união resina/dentina, por meio do ensaio de resistência da união à microtração e quantificar os íons flúor liberados do sistema adesivo. A superfície da face oclusal de terceiros molares humanos extraídos foi desgastada com lixa de carbeto de silício de granulação 600. Em seguida, os dentes foram separados em 2 grupos de acordo com o sistema adesivo utilizado (n=4): Clearfil Protect Bond (PB) (Kuraray) e Clearfil SE Bond (SE) (Kuraray). Um bloco de resina composta TPH (Dentsply) de aproximadamente 6 mm de espessura foi unido ao dente com os sistemas adesivos, preparados de acordo com as recomendações do fabricante e cada camada de 2 mm de espessura foi irradiada por 40 segundos. Após 24 horas em umidade relativa à 37º C, as amostras foram seccionadas perpendicularmente à área de união, para obter palitos com área de secção transversal de 1mm2 e separados em 6 grupos de acordo com o período de armazenagem: G1 - PBI (imediato - controle); G2 - PBC (ciclagem dinâmica de pH); G3 - PBA (armazenagem em água deionizada por 140 dias); G4 - SEI (imediato - controle); G5 - SEC (ciclagem dinâmica de pH); e, G6 - SEA (armazenagem em água deionizada por 140 dias). Em seguida, os palitos foram submetidos ao ensaio de resistência de união à microtração em máquina de ensaio universal (Instron) a velocidade de 0,5 mm/minuto. Para análise da liberação de flúor, os palitos foram armazenados individualmente em 1 mL de solução DES (n=8), RE (n=8) ou água deionizada (n=23) para o sistema adesivo Clearfil Protect Bond com um eletrodo íon específico conectado a um potenciômetro, usando 0,05 mL do sistema tampão concentrado TISAB III adicionado a 0,5 mL da solução da amostra, por 1 a 4 (DES, RE e água deionizada) e 30 dias (água deionizada). Os dados foram submetidos à Análise de Variância, ao teste de Tukey (5%) e ao teste de Friedman's. Os valores de resistência de união à microtração (MPa) foram: 30,4±11,6 (PBI), 29,5±9,1 (PBC), 27,1±11,6 (PBA), 28,9±11,1 (SEI), 27,1±7,6 (SEC) e 21,3±10,9 (SEA). Nenhuma diferença estatística foi observada entre os dois sistemas adesivos em todas as condições de tratamento (p>0,05). O PBI e o SEI apresentaram valores de resistência de união à microtração significativamente maiores em relação ao PBA e ao SEA (p<0,05). A ciclagem dinâmica de pH no PB e SE não mostrou diferença significativa nos valores de resistência de união à microtração, quando comparado com o imediato e a armazenagem em água deionizada por 140 dias (p>0,05). A concentração de flúor presente nas soluções DES/RE foi menor que 0,03125 ppm e nenhuma quantidade esteve presente na água, para o sistema adesivo testado (Clearfil Protect Bond). Conclui-se, portanto, que nenhuma diferença significativa foi observada entre os sistemas adesivos. A armazenagem em água deionizada por 140 dias diminuiu os valores de resistência da união à microtração, para os dois sistemas adesivos. / Abstract: The purpose of this study was to evaluate the effect of the dynamic chemical challenge pH (DES/RE solutions) and storage regimen on degradation of resin/dentin-bonding using the microtensile bond strength (µTBS) and quantify fluoride release from the adhesive system. Superficial occlusal dentin of extracted human molars was exposed and wet ground with 600-grit SiC paper. Then, teeth were randomly distributed into 2 groups according to adhesive systems (n=4): Clearfil Protect Bond (PB) (Kuraray) and Clearfil SE Bond (SE) (Kuraray). A block of composite resin TPH (Dentsply) with 6 mm thickness was bonded to the tooth with the adhesive systems according to manufacturer's instructions and each thickness with 2 mm was light cured for 40 seconds. After 24 hours in moist environment at 37oC, the specimens were sectioned perpendicular to the bonding area to obtain 1mm2 sectional area sticks, which were randomly divided into 6 groups according to storage regimen: G1 - PBI (immediate-control); G2 - PBC (pH cycling model); G3 - PBW (140 days water storage); G4 - SEI (immediate - control); G5 - SEC (pH cycling model); and, G6 - SEW (140 days water storage). After that, the sticks were submitted to microtensile bond strength (µTBS) test in a Universal machine (Instron) at a crosshead speed of 0.5mm/min. Fluoride concentration in demineralization (n=8) / remineralization (n=8) solutions and deionized water (n=23) was obtained by collecting 0,5 mL of these solutions and 0,05 mL of TISAB III, from 1 to 4 days ( De, Re and deionized water) and 30 days (deionized water). Fluoride release was detected using a fluoride-specific electrode connected to a microprocessor ion analyzer.The data were submitted to ANOVA and Tukey's tests (p<0.05) and Friedman's tests. Microtensile bond strength- µTBS (MPa) mean values were 30.4±11.6 (PBI), 29.5±9.1 (PBC), 27.1±11.6 (PBW), 28.9±11.1 (SEI), 27.1±7.6 (SEC) and 21.3±10.9 (SEW). There was no significantly statistical difference between PB and SE in all conditions of treatment (p>0.05). The PBI and SEI showed significantly higher µTBS values compared to PBW and SEW (p<0.05). The pH cycling model in the PB and SE didn't show significantly difference on µTBS values when compared immediate and the deionized water storage for 140 days (p>0.05). Fluoride concentrations present in the DES/RE were less than 0.03125 ppm and no in deionized water, regardless of the adhesive system tested. No significantly difference was found between adhesive systems in all conditions. The 140-day water storage decreased the µTBS values from two adhesives systems. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
49

Avaliação de três cimentos resinosos na resistência de união entre dentina e uma cerâmica de zircônia estabilizada por ítria

Castro, Humberto Lago de [UNESP] 01 June 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-01Bitstream added on 2014-06-13T18:58:13Z : No. of bitstreams: 1 castro_hl_me_sjc.pdf: 1527108 bytes, checksum: e3b403c8e46c094fafb49bdc789f3c3b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivou-se avaliar a resistência à tração (σ) da união de três sistemas de cimentação resinosa de ativação dual (RelyX ARC, RelyX U100 e Panavia F) entre a dentina e uma cerâmica à base de zircônia estabilizada por óxido de ítrio (In-Ceram YZ, Vita Zanhfabrik) com diferentes tratamentos de superfície. A superfície oclusal de 54 terceiros molares humanos hígidos foi exposta e condicionada conforme as instruções de cada cimento. Cinqüenta e quatro blocos cerâmicos foram planificados e sinterizados (6,4 mm x 6,4 mm x 4,8 mm). Após, foram divididos em dois grupos conforme o tipo de tratamento de superfície: jateamento com óxido de alumínio ≤ 50 μm ou silicatização (CoJet, 3M ESPE)(24-28 psi). A cimentação à dentina foi realizada de acordo com as instruções de cada fabricante. Assim, foram constituídos 6 grupos. Os conjuntos foram armazenados em água destilada à 37°C por 24 h e cortados no sentido x e y, 9 corpos de prova (cp) por conjunto foram obtidos em média (área adesiva de ± 1 mm2). Os cp de cada conjunto foram divididos aleatoriamente em 3 condições de armazenagem: ensaio imediato; 60 dias de armazenagem em água destilada (37ºC) e termociclagem (10.000x, 5ºC - 55ºC) (n≥12). O ensaio de resistência adesiva por microtração foi realizado numa máquina de ensaio universal (1 mm/min). Nos grupos imediatos RelyX ARC-silicatização e Panavia Fjateamento apresentaram as médias mais altas de σ (13,9 e 13,0 MPa, respectivamente), seguido do RelyX U100-jateamento (10,2 MPa). Após a termociclagem, o cimento Panavia F-jateamento foi melhor (14,8 MPa) seguido pelo RelyX ARC-silicatização e RelyX U100-jateamento (12,9 e 9,9 MPa, respectivamente). Após a armazenagem por 60 dias, os cimentos se comportaram de forma semelhante, onde os grupos que foram silicatizados demonstraram uma tendência a valores mais elevados de σ (MPa) / The aim of this study was to evaluate the bond strength of three dualcured resin cement systems (RelyX ARC, RelyX U100 and Panavia F) to dentin and to an yttria-stabilized zirconia-based ceramic (In-Ceram YZ, Vita Zanhfabrik) after different surface treatments. The occlusal surface of 54 sound human third molars was exposed and conditioned according to the manufacturers’ instructions. Fifty-four ceramic blocks were cut (6.4mm x 6.4mm x 4.8mm), flattened and fired. They were divided into two groups according to the type of surface treatment: air-abrasion with ≤ 50μm alumina particles or CoJet system (3M ESPE) (14-28 psi). The cementation procedure followed the instructions of each manufacturer. Thus, there were 6 groups. All teeth-cement-ceramic blocks were stored in 37°C distilled water for 24 hours before cutting into non-trimming specimens (adhesive area= 1 mm²). About nine specimens (sp) were obtained per block (n=27). The specimens of each block were randomly assigned to one of the three storage conditions: dry- immediate test, W60- 60 days of storage (37°C water) and TC- thermocycling (10,000x) (n≥12). The microtensile bond strength test was performed using an universal testing machine (crosshead speed: 1 mm/min). Immediate groups of RelyX ARC-Cojet and Panavia F-air-abrasion presented the highest σ average (13.9 and 13.0 MPa, respectively), followed by RelyX U100-airabrasion (10,2 MPa). After TC, Panavia F-air-abrasion was the best (14.8 MPa) followed by RelyX ARC-Cojet and RelyX U100-air-abrasion (12.9 and 9.9 MPa, repectively). After W60, all the cements behaved similarly, when the groups were treated with Cojet system, tended to higher values of σ (MPa)
50

Influência do deslocamento do tecido subcutâneo na resistência a tração da parede abdominal apos a dissecção dos músculos abdomianis em cadáveres / The influence of the subcutaneos tissue undermining in the tensile strengh of the abdominal wall after disseccion of the abdominal muscles in cadavers

Kimura, Alexandro Kenji [UNIFESP] January 2005 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:06:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2005 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Introdução: A dissecção dos músculos abdominais reduz a tensão no fechamento de defeitos ventrais do abdome. Amplos descolamentos do tecido subcutâneo associados à estas dissecções são responsáveis por desvascularização, denervação e formação de espaço morto. Realizar descolamentos mais econômicos do tecido subcutâneo sem prejudicar a tensão é uma tática operatória desejada para reduzir complicações. Objetivo: Avaliar a influência do descolamento do tecido subcutâneo na resistência à tração da parede abdominal após a dissecção dos músculos abdominais em cadáveres. Métodos: Foram estudados 20 cadáveres. A resistência à tração medial, das lâminas anterior e posterior do músculo reto, foi medida em dois níveis - 3 cm acima e 2 cm abaixo do umbigo e, relacionada em um coeficiente de tração. Os coeficientes de tração foram obtidos em três fases seqüenciais de dissecção: 1) descolamento do tecido subcutâneo até a linha semilunar; 2) dissecção do músculo oblíquo externo e da lâmina posterior do músculo reto do abdome; 3) descolamento do tecido subcutâneo até a linha axilar anterior. A análise de variância de Friedman foi utilizada nas comparações dos coeficientes regionias de tração nas três fases de dissecção. O teste de Wilcoxon foi utilizado para comparação, em uma mesma fase, entre os coeficientes da região supra e infraumbilical e, entre os da lâmina anterior e posterior. O teste de Spearman foi utilizado na correlação entre os coeficientes regionais de tração, o IMC e as espessuras do tecido subcutâneo. Resultados: Após as dissecções músculoaponeuróticas não houve diferença estatisticamente significante quando o descolamento reduzido do tecido subcutâneo (fase 2) foi comparado ao xvi descolamento ampliado (fase 3). Os coeficientes dos níveis supra-umbilicais foram maiores que os infra-umbilicais, exceto para a lâmina anterior na fase 1. Os coeficientes da lâmina anterior foram maiores que os da posterior. Não houve correlação destes coeficientes com os valores de IMC e espessura do tecido subcutâneo. Conclusão: O descolamento do tecido subcutâneo além da linha semilunar não influi na resistência à tração da parede abdominal após a dissecção dos músculos abdominais em cadáveres. / Introduction: The dissection of the abdominal muscle decreases tension of the edges of the abdominal wall defect, allowing a tensionless closure. Large subcutaneous tissue underminig associated with these dissections are correlated with damage to vascularization, innervation and dead space. The techniques to corret abdominal wall defects should aim to reduce complications by performing economical subcutaneous tissue undermining, mantaining the reduction of tension.Objective: The purpouse of this study is to evaluate the influence of the undermining of the subcutaneous tissue in the tensile strength of the abdominal wall, after abdominal muscle dissection in cadavers.Methods: Twenty adult cadavers were studied. The resistance of the medial advancement of both anterior and posterior rectus sheaths were related to the traction index and measured in two levels - 3cm above and 2 cm bellow the umbilicus. Traction index were compared during three situations: (1) after de subcutaneous tissue undermining laterally to the semilunar line; (2) after the dissection of the rectus muscle from its posterior sheat associated with the release of the external oblique muscle; (3) after de subcutaneous tissue undermining laterally to the anterior axilar line. Friedman test was used to compare the mean traction index of each site in the three different stages of dissection. Wilcoxon test was used for comparison of the traction index of both supraumbilical and infraumbilical sites. It was also used to compare the traction indices of the anterior and posterior sheaths after each stage of dissections. Spearman test was used for the correlation between the traction index, body mass index (BMI), and the width of the subcutaneous tissue. Results: There was not a significant statistic difference 74 between the subcutaneous tissue undermining laterally to the semilunar line and that laterally the anterior axilar line, when associated with the musculoaponeurotic dissections. Comparison between supra-umbilical levels and infra-umbilical levels showed significant difference in all points, except in the anterior sheath in the first situation . Values of the traction index of the anterior rectus sheath showed statistically significant greater values than the posterior ones. There was not a correlation between the BMI and subcutaneous tissue width with the traction index. Conclusion: Subcutaneous tissue underminig beyond the semilunar line does not influence the tensile strength of the abdominal wall after the abdominal muscle dissection in cadavers. / BV UNIFESP: Teses e dissertações

Page generated in 0.4804 seconds