• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 16
  • 6
  • Tagged with
  • 51
  • 51
  • 29
  • 26
  • 22
  • 19
  • 18
  • 17
  • 14
  • 13
  • 13
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Fabrication additive de matériaux électroactifs pour applications à la mécatronique / Additive manufacturing of electroactive materials for mechatronics applications

Ganet-Mattei, Florent 05 February 2018 (has links)
La Fabrication Additive (FA) est un procédé de fabrication qui a commencé à se développer dans les années 80 et qui atteint actuellement une maturité qui lui permet d’être utilisé de manière rentable et fonctionnelle par les industriels. La fabrication additive est définie comme étant le procédé de mise en forme d’une pièce par ajout de matière, à l’opposé de la mise en forme traditionnelle par enlèvement de matière (usinage). Cette nouvelle technologie est une réelle révolution et permet de relever de nouveaux défis technologiques sans précédent. Que ce soit sur un axe matériau ou plus largement dans le cadre de l’usine du futur, la fabrication additive est un réel levier de croissance, mais de nombreux travaux de recherche sont encore à mener afin de perfectionner cette nouvelle technologie. C’est autour de cette problématique que les travaux de thèses se sont focalisés avec un accent sur l’intégration de matériaux électroactifs pour la réalisation de fonction mécatronique tirant profit des procédés de Fabrication Additive. Les actions de recherche montrent que la fabrication additive de matériaux électroactifs sera de plus en plus employée pour la réalisation de fonctions mécatroniques hybrides qui combineront à la fois la structure mécanique, des circuits intégrés en silicium, des pistes conductrices et des matériaux couplés imprimés, intégrant ainsi des fonctionnalités, telles que des capteurs, des affichages ou des sources d’énergie. Les travaux montrent le potentiel applicatif autour du contrôle de santé des structures en composites, mais aussi du contrôle de forme d’instrument pour la chirurgie. Pour arriver au développement de ces dispositifs, les points suivants ont été développés autour des matériaux électroactifs et de leurs règles d’intégrations et d’optimisation. / Additive Manufacturing (FA) is a manufacturing process that began to develop in the 1980s and is now mature enough to be used in a cost-effective and functional way by manufacturers. Additive manufacturing is defined as the process of shaping a part by adding material, as opposed to traditional shaping by material removal (machining). This new technology is a real revolution and enables us to meet new unprecedented technological challenges. Whether on a material axis or more widely as part of the plant of the future, additive manufacturing is a real growth driver, but many research work is yet to be conducted to perfect this new technology. It is around this issue that the work of theses focused with a focus on the integration of electroactive materials for the realization of mechatronics function taking advantage of Additive Manufacturing processes. Research shows that additive manufacturing of electroactive materials will be increasingly used for the realization of hybrid mechatronic functions that will combine both the mechanical structure, silicon integrated circuits, conductive tracks and printed coupled materials, integrating as well as features, such as sensors, displays or power sources. The work shows the potential application around the health control of composite structures, but also the instrument shape control for surgery. To arrive at the development of these devices, the following points have been developed around electroactive materials and their integration and optimization rules.
42

Contribution à la conception et la modélisation des systèmes mécatroniques (et de leurs sous-systèmes mécaniques

Marquis-Favre, Wilfrid 25 January 2007 (has links) (PDF)
Ce mémoire d'Habilitation à Diriger des Recherches présente tout d'abord au chapitre 1 une vue globale et synthétique de mes activités depuis ma prise de poste en septembre 1998. Le chapitre 2, « Bilan des activités depuis la prise de poste », détaille le contenu de ma recherche, de mon enseignement et des responsabilités administratives. Il tente de mettre en évidence les liens forts de mes activités de recherche à celles d'enseignement. Le chapitre 3, « Développement des activités de recherche », présente de manière approfondie et technique les principaux travaux de recherche menés durant cette période. Il montre comment ces travaux ont évolué progressivement d'un contexte « post doctoral » sur des sujets en continuité de celui de ma thèse de doctorat vers une volonté d'animer un axe de recherche en proposant de nouveaux sujets au sein du laboratoire. La transition s'est effectuée par l'appropriation de l'axe de recherche en question. Le chapitre 4, « Conclusion et perspectives », présente un bilan général de l'évolution de mes activités de recherche et les met en perspectives à travers un certain nombre de propositions que je souhaite développer à l'avenir. Enfin, trois annexes récapitulent mes productions scientifiques, ma participation à la communauté et mon activité contractuelle, et finalement les textes des productions jugées les plus significatives par rapport à mes activités de recherche. Cette dernière annexe est fournie dans un document séparé pour en faciliter sa lecture.
43

Optimization and validation of a new 3D-US imaging robot to detect, localize and quantify lower limb arterial stenoses

Janvier, Marie-Ange 10 1900 (has links)
L’athérosclérose est une maladie qui cause, par l’accumulation de plaques lipidiques, le durcissement de la paroi des artères et le rétrécissement de la lumière. Ces lésions sont généralement localisées sur les segments artériels coronariens, carotidiens, aortiques, rénaux, digestifs et périphériques. En ce qui concerne l’atteinte périphérique, celle des membres inférieurs est particulièrement fréquente. En effet, la sévérité de ces lésions artérielles est souvent évaluée par le degré d’une sténose (réduction >50 % du diamètre de la lumière) en angiographie, imagerie par résonnance magnétique (IRM), tomodensitométrie ou échographie. Cependant, pour planifier une intervention chirurgicale, une représentation géométrique artérielle 3D est notamment préférable. Les méthodes d’imagerie par coupe (IRM et tomodensitométrie) sont très performantes pour générer une imagerie tridimensionnelle de bonne qualité mais leurs utilisations sont dispendieuses et invasives pour les patients. L’échographie 3D peut constituer une avenue très prometteuse en imagerie pour la localisation et la quantification des sténoses. Cette modalité d’imagerie offre des avantages distincts tels la commodité, des coûts peu élevés pour un diagnostic non invasif (sans irradiation ni agent de contraste néphrotoxique) et aussi l’option d’analyse en Doppler pour quantifier le flux sanguin. Étant donné que les robots médicaux ont déjà été utilisés avec succès en chirurgie et en orthopédie, notre équipe a conçu un nouveau système robotique d’échographie 3D pour détecter et quantifier les sténoses des membres inférieurs. Avec cette nouvelle technologie, un radiologue fait l’apprentissage manuel au robot d’un balayage échographique du vaisseau concerné. Par la suite, le robot répète à très haute précision la trajectoire apprise, contrôle simultanément le processus d’acquisition d’images échographiques à un pas d’échantillonnage constant et conserve de façon sécuritaire la force appliquée par la sonde sur la peau du patient. Par conséquent, la reconstruction d’une géométrie artérielle 3D des membres inférieurs à partir de ce système pourrait permettre une localisation et une quantification des sténoses à très grande fiabilité. L’objectif de ce projet de recherche consistait donc à valider et optimiser ce système robotisé d’imagerie échographique 3D. La fiabilité d’une géométrie reconstruite en 3D à partir d’un système référentiel robotique dépend beaucoup de la précision du positionnement et de la procédure de calibration. De ce fait, la précision pour le positionnement du bras robotique fut évaluée à travers son espace de travail avec un fantôme spécialement conçu pour simuler la configuration des artères des membres inférieurs (article 1 - chapitre 3). De plus, un fantôme de fils croisés en forme de Z a été conçu pour assurer une calibration précise du système robotique (article 2 - chapitre 4). Ces méthodes optimales ont été utilisées pour valider le système pour l’application clinique et trouver la transformation qui convertit les coordonnées de l’image échographique 2D dans le référentiel cartésien du bras robotisé. À partir de ces résultats, tout objet balayé par le système robotique peut être caractérisé pour une reconstruction 3D adéquate. Des fantômes vasculaires compatibles avec plusieurs modalités d’imagerie ont été utilisés pour simuler différentes représentations artérielles des membres inférieurs (article 2 - chapitre 4, article 3 - chapitre 5). La validation des géométries reconstruites a été effectuée à l`aide d`analyses comparatives. La précision pour localiser et quantifier les sténoses avec ce système robotisé d’imagerie échographique 3D a aussi été déterminée. Ces évaluations ont été réalisées in vivo pour percevoir le potentiel de l’utilisation d’un tel système en clinique (article 3- chapitre 5). / Atherosclerosis is a disease caused by the accumulation of lipid deposits inducing the remodeling and hardening of the vessel wall, which leads to a progressive narrowing of arteries. These lesions are generally located on the coronary, carotid, aortic, renal, digestive and peripheral arteries. With regards to peripheral vessels, lower limb arteries are frequently affected. The severity of arterial lesions are evaluated by the stenosis degree (reduction > 50.0 % of the lumen diameter) using angiography, magnetic resonance angiography (MRA), computed tomography (CT) and ultrasound (US). However, to plan a surgical therapeutic intervention, a 3D arterial geometric representation is notably preferable. Imaging methods such as MRA and CT are very efficient to generate a three-dimensional imaging of good quality even though their use is expensive and invasive for patients. 3D-ultrasound can be perceived as a promising avenue in imaging for the location and the quantification of stenoses. This non invasive, non allergic (i.e, nephrotoxic contrast agent) and non-radioactive imaging modality offers distinct advantages in convenience, low cost and also multiple diagnostic options to quantify blood flow in Doppler. Since medical robots already have been used with success in surgery and orthopedics, our team has conceived a new medical 3D-US robotic imaging system to localize and quantify arterial stenoses in lower limb vessels. With this new technology, a clinician manually teaches the robotic arm the scanning path. Then, the robotic arm repeats with high precision the taught trajectory and controls simultaneously the ultrasound image acquisition process at even sampling and preserves safely the force applied by the US probe. Consequently, the reconstruction of a lower limb arterial geometry in 3D with this system could allow the location and quantification of stenoses with high accuracy. The objective of this research project consisted in validating and optimizing this 3D-ultrasound imaging robotic system. The reliability of a 3D reconstructed geometry obtained with 2D-US images captured with a robotic system depends considerably on the positioning accuracy and the calibration procedure. Thus, the positioning accuracy of the robotic arm was evaluated in the workspace with a lower limb-mimicking phantom design (article 1 - chapter 3). In addition, a Z-phantom was designed to assure a precise calibration of the robotic system. These optimal methods were used to validate the system for the clinical application and to find the transformation which converts image coordinates of a 2D-ultrasound image into the robotic arm referential. From these results, all objects scanned by the robotic system can be adequately reconstructed in 3D. Multimodal imaging vascular phantoms of lower limb arteries were used to evaluate the accuracy of the 3D representations (article 2 - chapter 4, article 3 - chapter 5). The validation of the reconstructed geometry with this system was performed by comparing surface points with the manufacturing vascular phantom file surface points. The accuracy to localize and quantify stenoses with the 3D-ultrasound robotic imaging system was also determined. These same evaluations were analyzed in vivo to perceive the feasibility of the study.
44

Suivi 3D Robuste pour la Chirurgie Cardiaque Robotisee

Richa, Rogerio 23 April 2010 (has links) (PDF)
Les dernières décennies ont vu le développement important de la chirurgie mini-invasive. L'acte mini-invasif apporte de nombreux avantages pour les patients: séjour plus court à l'hôpital, réduction des coûts, un traumatisme réduit et la diminution des complications postopératoires. Dans ce contexte, l'assistance robotique est capable de rendre l'acte chirurgical plus intuitif et plus sûr pour les chirurgiens. Dans le domaine de la chirurgie cardiaque mini-invasive, les mouvements respiratoires et cardiaques sont deux sources de perturbations importantes pour les chirurgiens. Malgré l'existence de versions miniaturisées de stabilisateurs cardiaques mécaniques, le mouvement résiduel est encore considérable et doit être manuellement compensé par le chirurgien. Dans ces travaux de thèse, des techniques de suivi visuel pour l'estimation du mouvement 3D du coeur ont été développées. Pour la compensation active des mouvements physiologiques, seules les structures naturelles sur la surface du coeur sont utilisées. Deux contributions dans le domaine de la compensation des mouvements physiologiques pour la chirurgie cardiaque robotisée ont été proposées. La première est une méthode de suivi visuel 3D basée sur un modèle déformable de type ''plaque mince'' et une paramétrisation efficace pour le suivi 3D en images stéréo-endoscopiques. La seconde contribution est une méthode de suivi robuste qui prédit le mouvement futur du coeur pour contourner des problèmes comme les occlusions par les instruments chirurgicaux et les éventuelles réflexions spéculaires. La méthode de prédiction est basée sur une série de Fourier estimée à travers un filtre de Kalman étendu.
45

Contribution à une conception appropriée de robots médicaux : vers une démarche mécatronique / Contribution to an appropriate design of medical robots : towards a mechatronic approach

Drouin, Christophe 18 December 2013 (has links)
Dans cette thèse, nous apportons la contribution à la conception de robots médicaux, en proposant une démarche de conception simultanée de la structure mécanique du robot. Par opposition à une vision séquentielle naturelle de la conception, la formalisation du processus créatif permet une simultanéité, ouvrant la voie à des structures innovantes dédiées : en robotique médicale, faible masse et faible compacité de la structure mécanique sont souvent recherchées. A partir d’un descriptif de démarches existantes, nous effectuons la conception d’un robot de télé-échographie et d’un robot de chirurgie mini-invasive. Pour les deux applications, de fortes contraintes sont présentes. En télé-échographie, la portabilité est très recherchée, requérant une faible compacité. Pour la chirurgie mini-invasive, les moto-réducteurs du robot in vivo doivent être dimensionnés au plus juste. Ici, nous avons formalisé l’amélioration de la compacité d’une structure parallèle pour la télé-échographie. Les résultats montrent une amélioration de la compacité de l’ordre de 5%. Dans le même esprit, nous avons formalisé la synthèse dimensionnelle de deux robots 2R-R-R de chirurgie mini-invasive in vivo. Nous réalisons l’optimisation simultanée entre le dimensionnement des moto-réducteurs et des longueurs des corps pour tendre vers une simultanéité totale du processus créatif, ce qui nous permet d’améliorer les performances en termes de force et vitesse à l’effecteur. Ces expériences de conception montrent les limites à une simultanéité stricte. Nous indiquons le besoin d’adapter outils et méthodes de conception mécatronique pour une simultanéité en conception robotique tenant compte de l’aspect imparfait du processus créatif. / In this thesis, we propose a contribution to the design of medical robots, by offering a concurrent design or simultaneous approach. As opposed to a natural sequential view of the design process, the formalization of the creative process allows simultaneity, paving the way for innovative structures, dedicated: in the medical robotic field, low mass and low compactness of the mechanical structure are often sought. From a description of existing approaches, we design a tele-ultrasound robot and a minimally invasive surgery robot. For both applications, high physical integration is required. For tele-ultrasound robots, portability is highly sought, requiring low compactness. For minimally invasive surgery, geared motors of the in vivo robot must be sized correctly. Here, we formalized the improvement of compactness of an existing parallel structure for remote ultrasound application. The results show an improvement of compactness of around 5%. In the same way, we formalize the dimensional synthesis of two robots 2R-R-R for in vivo minimally invasive surgery. The results show the under-sizing of some actuators. We perform simultaneous optimization between the design of geared motors and lengths of the body of a robot 2R-RR, tendering towards full simultaneity of the creative process, allowing to improve minimal force and velocity at the end-effector of the robot. These experiments of design show limits to a strict simultaneity. We indicate the need to adapt the tools and methods of mechatronic design for simultaneous robotics design, taking into account the imperfect aspect of the creative process.
46

Plateforme de vidéo mobile de télé-échographie robotisée sur un réseau 4G-LTE / Mobile video tele-echography robotic platform over 4G-LTE network

Avgousti, Sotiris 01 December 2016 (has links)
L'objectif de cette thèse est le déploiement et l'évaluation d'une plate-forme de télé-échographie mobile, utilisée pour fournir un diagnostic et des soins à distance dans des milieux médicalement isolés. La plateforme intègre de nouveaux concepts qui permettent de l’utilisation de la télé-échographie robotisée sur les réseaux sans fil 3G, 4G et 5G pour satisfaire au transfert de qualité des vidéos ultrasonores pour un diagnostic médical robuste. Ce travail contribue au domaine des Sciences et Technologies de l'Information et de la Communication appliquées au secteur de la santé et en particulier à la robotique médicale téléopérée. Les principales contributions de la thèse sont : I. Un état de l’art des systèmes télé-robotiques appliqués au médical menée sur la base de publications écrites entre 2004 et 2016, II. L'évaluation objective et subjective (clinique) de la qualité vidéo a démontré que les normes H.264/AVC et HEVC peuvent atteindre une qualité vidéo sans perte de diagnostic à des débits (1024 et 2048 Kbps) bien en deçà des débits de données supportés par les réseaux 4G. Les normes de codage vidéo antérieures (Mpeg-4, Mpeg-2) ne peuvent pas être utilisées pour le diagnostic clinique à ces débits car elles présentent une perte d'information pour le diagnostic médical, III. Les experts médicaux ont apprécié la réactivité dynamique mécanique de la plate-forme en raison du faible délai présenté par les canaux LTE. La limitation la plus importante soulevée par l'expert médical, empêchant une évaluation globale clinique favorable au diagnostic, était le positionnement initial du robot sur le corps du patient et son déplacement vers l'obtention d’une échographie cardiaque, Les résultats fournissent une forte indication que la plate-forme télé-échographie robotisée peut être utilisée pour fournir un diagnostic fiable et à distance sur les réseaux sans fil émergents 4G et au-delà. / The objective of this Thesis was the deployment and evaluation of an end-to-end mobile tele-echography platform used to provide remote diagnosis and care within medically isolated settings. The platform integrates new concepts that enable robotized tele-echography over commercially available 4G and beyond mobile networks for rendering diagnostically robust medical ultrasound video. It contributes to the field of Information and Communication technologies applied in the healthcare sector. The main contributions of the Thesis are: I. A systematic review on the state of the art in medical telerobotic systems was conducted based on publications of the last decade, and more specifically between the years 2004 to 2016. II. Both objective and subjective (clinical) video quality assessment demonstrated that H.264/AVC and HEVC standards can achieve diagnostically-lossless video quality at bitrates (1024 and 2048 Kbps) well within the LTE supported data rates. Earlier video coding standards (Mpeg-4 & Mpeg-2) cannot be employed for clinical diagnosis at these rates as they present loss of clinical information.III. Medical experts highly appreciated the proposed platform’s mechanical dynamic responsiveness due to the low end-to-end delay (latency) facilitated by LTE-channels. The most important limitation raised by the medical expert and prevented higher overall rating and ultimately clinical QoE was the robot initial positioning on the patient’s body and navigation towards obtaining the cardiac ultrasound. IV. Results provides a strong indication that the proposed robotized tele-echography platform can be used to provide reliable, remote diagnosis over emerging 4G and beyond wireless networks.
47

Path reconstruction in diffusion tensor magnetic resonance imaging / Reconstitution de la trajectoire dans le diffusion tenseur magnétique résonance imagerie

Song, Xin 13 July 2011 (has links)
L'environnement sous-marin compliqué et la pauvre vision sous-marine font le robot câblé sous-marin super-mini-à peine pour être contrôlés. Traditionnellement, la méthode de contrôle manuelle par les opérateurs est adoptée par cette sorte de robots. Malheureusement, les robots peuvent à peine travailler normalement dans ces circonstances pratiques. Donc, pour surmonter ces manques et améliorer les capacités de ces robots câblés sous-marins, ce papier propose plusieurs améliorations, en incluant le design de système, le design de contrôleur de mouvement, la reconnaissance d'obstacle en trois dimensions et les technologies de reconstruction de sentier en trois dimensions etc. (1) Super-mini sous-marins de conception système de robot: plusieurs programmes d'amélioration et d'idées de conception importants sont étudiés pour la super-mini robot sous-marin (2) La conception du contrôleur de mouvement du robot sous-marin dans des circonstances compliquées est étudiée. Un nouveau réseau de neurones adaptatif coulissantes contrôleur de mode avec le contrôleur paramètre équilibrée est proposé. Basé sur la théorie de la gestion adaptative floue contrôleur de mode coulissant , un algorithme amélioré est également proposé et appliqué à l'robot sous-marin. (3) Recherche de reconstructions d'environnement sous-marines en trois dimensions : les algorithmes et les expériences de reconstructions d'environnement sous-marines sont enquêtés. L'algorithme de traitement d'image de DT-MRI et la théorie de reconstructions d'obstacle en trois dimensions sont adoptés et améliorés pour l'application du robot sous-marin. / The complicated underwater environment and the poor underwater vision make super-mini underwater cable robot hardly to be controlled. Traditionally, the manual control method by operators is adopted by this kind of robots. Unfortunately, the robots can hardly work normally in these practical circumstances. Therefore, to overcome these shortcomings and improve the abilities of these underwater cable robots, this paper proposes several improvements, including the system design, the motion controller design, three dimensional obstacle recognition and three dimensional path reconstruction technologies etc. The details are displayed as follow: (1) Super-mini underwater robot system design: several improvement schemes and important design ideas are investigated for the super-mini underwater robot.(2) Super-mini robot motion controller design: The motion controller design of underwater robot in complicated circumstance is investigated. A new adaptive neural network sliding mode controller with balanced parameter controller (ANNSMB) is proposed. Based on the theory of adaptive fuzzy sliding mode controller (AFSMC), an improved algorithm is also proposed and applied to the underwater robot. (3)Research of three dimensional underwater environment reconstructions: The algorithms and the experiments of underwater environment reconstructions are investigated. DT-MRI image processing algorithm and the theory of three dimensional obstacle reconstructions are adopted and improved for the application of the underwater robot. (4) The super-mini underwater robot path planning algorithms are investigated.
48

Context-aware radiation protection for the hybrid operating room / Méthodes de radioprotection réactives au contexte pour la salle d’opération hybride

Loy Rodas, Nicolas 19 February 2018 (has links)
L’utilisation de systèmes d’imagerie à rayons X lors de chirurgies mini-invasives expose patients et staff médical à des radiations ionisantes. Même si les doses absorbées peuvent être faibles, l’exposition chronique peut causer des effets nocifs (e.g. cancer). Dans cette thèse, nous proposons des nouvelles méthodes pour améliorer la sécurité vis-à-vis des radiations ionisantes en salle opératoire hybride dans deux directions complémentaires. Premièrement, nous présentons des approches pour rendre les cliniciens plus conscients des irradiations grâce à des visualisations par réalité augmentée. Deuxièmement, nous proposons une méthode d'optimisation pour suggérer une pose de l’imageur réduisant la dose au personnel et patient, tout en conservant la qualité de l’image. Pour rendre ces applications possibles, des nouvelles approches pour la perception de la salle grâce à des caméras RGBD et pour la simulation en temps-réel de la propagation et doses de radiation ont aussi été proposées. / The use of X-ray imaging technologies during minimally-invasive procedures exposes both patients and medical staff to ionizing radiation. Even if the dose absorbed during a single procedure can be low, long-term exposure can lead to noxious effects (e.g. cancer). In this thesis, we therefore propose methods to improve the overall radiation safety in the hybrid operating room by acting in two complementary directions. First, we propose approaches to make clinicians more aware of exposure by providing in-situ visual feedback of the ongoing radiation dose by means of augmented reality. Second, we propose to act on the X-ray device positioning with an optimization approach for recommending an angulation reducing the dose deposited to both patient and staff, while maintaining the clinical quality of the outcome image. Both applications rely on approaches proposed to perceive the room using RGBD cameras and to simulate in real-time the propagation of radiation and the deposited dose.
49

Nouveaux concepts de robots à tubes concentriques à micro-actionneurs à base de polymères électro-actifs / New concept of concentric tube robots with micro-actuators based on electro-active polymers

Chikhaoui, Mohamed Taha 17 November 2016 (has links)
L’utilisation de systèmes robotiques pour la navigation dans des zones confinées pose des défis intéressants sur les thèmes de conception, de modélisation et de commande, particulièrement complexes pour les applications médicales. Dans ce contexte, nous introduisons un nouveau concept de robots continus, fortement prometteurs pour des applications biomédicales, dont la forme complexe, la dextérité et la capacité de miniaturisation constituent des avantages majeurs pour la navigation intra corporelle. Parmi cette classe, les robots à tubes concentriques (RTC), qui constituent notre point de départ, sont améliorés grâce à un actionnement embarqué innovant. Nos travaux s’articulent autour de deux thématiques aux frontières de l’état de l’art. D’une part, nous avons proposé une modélisation générique et conduit une analyse cinématique approfondie de robots continus basés sur l’architecture des RTC standards et ceux avec changement de courbure de leurs tubes dans deux variantes : courbures unidirectionnelle et bidirectionnelle. D’autre part, leur commande cartésienne en pose complète est introduite avec une validation expérimentale sur un prototype développé de RTC standard, ainsi que les simulations numériques d’une loi de commande comprenant la gestion de la redondance des RTC à changement de courbure. D’autre part, nous avons effectué la synthèse, la caractérisation et la mise en œuvre de micro-actionneurs souples basés sur les polymères électro-actifs (PEA), intégrés pour la première fois dans un robot continu.Ainsi, l’asservissement visuel d’un prototype de robot télescopique souple est proposé avec des précisions atteignant 0.21 mm sur différentes trajectoires. / Major challenges need to be risen in order to perform navigation in confined spaces with robotic systems in terms of design, modeling, and control, particularly for biomedical applications. Indeed,the complex shape, dexterity, and miniaturization ability of continuum robots can help solving intracorporeal navigation problems. Within this class, we introduce a novel concept in order to augment the concentric tube robots (CTR) with embedded actuation. Our works hinge on two majorcutting-edge thematics. On the one hand, we address modeling and kinematics analysis of standard CTR as well as variable curvature CTR with their two varieties : single and double bending directions.Furthermore, we perform the experimental validation of Cartesian control of a CTR prototype, anda task hierarchy based control law for redundancy resolution of CTR with variable curvatures. Onthe other hand, we develop the synthesis, the characterization, and the integration of soft microactuatorsbased on electro-active polymers (EAP) for the first time in a continuum robot. Thus, thevisual servoing of a telescopic soft robot is performed with precisions down to 0.21 mm following different trajectories.
50

Compensation des mouvements physiologiques en chirurgie robotisée par commande prédictive

Ginhoux, Romuald 18 December 2003 (has links) (PDF)
Il existe aujourd'hui de nombreux systèmes robotiques commerciaux pour l'assistance au geste chirurgical. Les interventions d'orthopédie, de neurologie, de chirurgie laparoscopique ou cardiaque peuvent désormais être assistées par des systèmes mécaniques et informatiques. Depuis les premiers robots d'aide au geste chirurgical dérivés des robots industriels, aux robots actuels, l'objectif est de développer des systèmes d'aide aux gestes médicaux et chirurgicaux qui apportent des bénéfices importants au chirurgien et au patient. Dans ce contexte, ce travail de thèse s'intéresse plus particulièrement à l'aide au geste chirurgical en chirurgie mini-invasive robotisée. La problématique abordée est de permettre à un robot chirurgical de compenser mécaniquement les mouvements physiologiques de l'organe ou du tissu opéré, afin de proposer au chirurgien une zone de travail virtuellement immobile. En effet, ces mouvements sont des perturbations pour le chirurgien qui télé-manipule un robot, car il doit les compenser lui-même à chaque fois qu'une tâche précise est requise à la surface d'un organe ou d'un tissu, en les accompagnant manuellement quand c'est possible. Ceci limite aujourd'hui le développement, entre autres, des opérations à coeur battant. L'objectif est de proposer un système de commande qui permette au robot de se déplacer de façon synchronisée avec l'organe et d'accompagner ainsi son mouvement. Ce travail se restreint aux mouvements physiologiques dus à la respiration et aux battements du coeur. Ceux-ci sont périodiques avec une période qui ne varie pas pendant l'intervention. Le principe utilisé pour commander le déplacement du robot est celui de l'asservissement visuel direct rapide, où les images d'une caméra d'observation endoscopique sont traitées en temps réel, avec une cadence d'asservissement jusqu'à 500 images par seconde. Le robot est commandé à l'aide de lois de commande prédictives dans lesquelles des modèles internes simples du robot et des mouvements à filtrer sont inclus. Les développements présentés dans cette thèse sont illustrés par deux ensembles de résultats, pour la compensation des mouvements respiratoires du foie d'une part, et le suivi du coeur battant d'autre part. Des dispositifs expérimentaux ont été mis en place autour d'un robot médical Aesop (Computer Motion, USA) et un prototype de robot chirurgical de la société Sinters de Toulouse. Des expériences de laboratoire et des tests in vivo en conditions chirurgicales réelles ont été réalisés.

Page generated in 0.0792 seconds