• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 474
  • 214
  • 44
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 739
  • 351
  • 156
  • 124
  • 98
  • 86
  • 75
  • 60
  • 59
  • 59
  • 59
  • 59
  • 56
  • 55
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Utilisation des hautes pressions hydrostatiques pour la modulation des interactions protéiques et la séparation des protéines sériques

Marciniak, Alice 24 January 2019 (has links)
La valorisation du lactosérum par le fractionnement de molécules à hautes valeurs ajoutées est d’autant plus d’actualité au Québec, que ce sous-produit est encore considéré comme une matière résiduelle fertilisante. Bien que les concentrés de protéines sériques possèdent des propriétés nutritionnelles et fonctionnelles intéressantes, la production de protéines sous forme purifiée est davantage désirée pour leur utilisation dans des produits de qualité et très recherchés notamment dans les formulations infantiles. De manière générale, la séparation des protéines est réalisée à l’aide de technologies présentant un impact environnemental et économique non négligeable ainsi qu’une efficacité non optimale voire limitée. Dans le cas des protéines sériques majeures (alpha-lactalbumine – α-la et bêta-lactoglobuline – β-lg), la principale problématique reliée à leur récupération sélective concerne leur poids moléculaire similaire. L’utilisation de technologies émergentes et écoresponsables devient donc un incontournable, de manière à améliorer les procédés déjà existants. Cette thèse avait donc pour but de montrer que la modulation des interactions protéiques par l’utilisation des hautes pressions hydrostatiques (HPH), une technologie considérée comme éco-efficiente et émergente, et l’utilisation d’un ligand, les caséines (CN), permettrait de fractionner ces deux protéines majeures pour la génération de fractions purifiées à des rendements maximaux. Une première étude a permis de déterminer les paramètres optimaux de pressurisation (temps et niveau de pression) ainsi que le type de ligand utilisé (CN isoélectriques – CI ou micellaires – CM). De manière générale, les HPH ont permis de spécifiquement agréger la β-lg et les CN, tout en maintenant l’α-la sous sa forme monomérique. L’acidification subséquente à pH 4,6 a généré une précipitation de ces agrégats de β-lg/CN. L’augmentation du niveau de pression et de temps a permis d’augmenter l’agrégation entre la β-lg et les CN sans impacter significativement l’agrégation de l’α-la. De plus, l’utilisation de CI en comparaison aux CM n’a pas permis d’améliorer le taux de purification de l’α-la alors que le rendement de cette dernière a diminué. Une deuxième étude a porté sur l’évaluation du potentiel concentration-dépendant des CN à agir comme un ligand pour le fractionnement de l’α-la et la β-lg. De manière générale, l’augmentation de la concentration en CN n’a pas permis d’améliorer les taux de purification et les rendements en α-la. Au contraire, pour des concentrations élevées en CN, le taux d’agrégation de la β-lg diminuait, suggérant un effet chaperon des CN sur l’agrégation par les HPH de la β-lg. En outre, la pressurisation des protéines sériques sans CN a permis d’obtenir les meilleurs paramètres de purification en α-la ainsi qu’en β-lg. Finalement, une troisième étude a permis de mettre en avant l’effet chaperon de la β-CN sur l’agrégation de la β-lg en présence d’α-la. Alors que la pressurisation des protéines sériques seules ou combinées entraînait la formation d’agrégats globulaires de faibles poids moléculaires et générait des solutions turbides, l’ajout de β-CN a permis de réduire la turbidité des solutions, et ce, proportionnellement à sa concentration. En parallèle, cette limpidité corrélait avec la présence d’agrégats de types amorphes et de hauts poids moléculaires. Finalement, comme requis pour une protéine chaperonne, il a été démontré que la β-CN n’était pas impliquée dans ces agrégats. Les travaux de cette thèse ont rencontré l’ensemble des objectifs définis et contribuent significativement à l’avancement des connaissances concernant l’extension de l’application des HPH pour le fractionnement de l’α-la et la β-lg présentant ainsi des taux de purification et des rendements d’intérêt majeur pour l’industrie de transformation des produits laitiers. / Whey valorization through the better fractionation of highly valuable molecules is more than ever relevant in Quebec, as it is still used as a fertilizing residual material. Although whey protein concentrates have multiple nutritional and functional properties, the production of highly pure single proteins is more desired for their use in high quality product and in particular for infant formula. Usually, proteins separation is done using technologies with significant environmental and economic impacts as well as non-optimized effectiveness. For the major whey proteins such as alpha-lactalbumin (α-la) and beta-lactoglobulin (β-lg), the main problematic is their similar molecular weight. Consequently, the use of emerging and green technologies is crucial to improve the efficiency and productivity of existing processes. This thesis aims to demonstrate the potential of using a green and emerging technology known as high hydrostatic pressure (HHP) coupled with a ligand, caseins (CN) for the modulation of proteinprotein interactions to improve the fractionation of the two major whey proteins: α-la and β-lg with higher purity. In the first study, optimal pressurization parameters (duration and level of pressure) as well as ligand type (isoelectric CN – IC or micellar – MC) were determined. Broadly, HHP treatment induced specific aggregation of β-lg and CN, while maintaining α-la in its monomeric form. Subsequent acidification to pH 4.6 caused the precipitation of the β-lg/CN aggregates. Increase of pressure and process duration increased the β-lg/CN aggregation without significantly impacting α-la aggregation. Furthermore, the use of IC in comparison with MC improved the purification rate of α-la while decreasing its recovery rate. As part of a second study, the evaluation of concentration of CN as a ligand for the fractionation of α-la and β-lg was studied. The increase in CN concentration did not improve both the purification and recovery rates of α-la. Rather, at higher CN concentration, β-lg aggregation rate decreased, suggesting a chaperone-like effect of CN on the β-lg pressure-induced aggregation. In addition, pressurization of whey proteins in the absence of CN, resulted in a higher purification rate and recovery degree for both α-la and β-lg in soluble and insoluble fractions, respectively. Lastly, in the third study, the chaperone-like effect of β-CN on the pressure-induced aggregation of β-lg and α-la was investigated. Pressurization of single or combined whey proteins generated small globular aggregates with turbid solutions, whereas, the addition of β-CN decreased the turbidity in a concentration dependent manner. In parallel, limpidity was correlated with the presence of larger but amorphous aggregates with higher molecular weight. Furthermore, it was demonstrated that β-CN was not part of the aggregates formed, which is an important criterion of a chaperone-like protein. The present work has met all the objectives set in this thesis and contributed significantly to the advancement of knowledge concerning the application of HHP for the fractionation of α-la and β-lg with high purification and recovery rates, which is of great interest for the dairy processing industry.
182

Fractionnement d'un hydrolysat de protéines de soya : comparaison des technologies baro-membranaire (UF) et électro-membranaire (ÉDUF) pour la collecte de fractions bioactives

Roblet, Cyril Roland 18 April 2018 (has links)
Depuis plusieurs décennies, de nombreuses recherches ont porté leur attention sur les bioactivités des constituants du soya, depuis les isoflavones jusqu'aux protéines, en passant par les peptides. L'objectif principal de ce travail de thèse était de démontrer qu'à partir de l'hydrolyse enzymatique de protéines de soya par la pepsine et la pancreatine, il était possible d'isoler et de concentrer des peptides bioactifs plus efficacement par la technique d'électrodialyse avec membranes d'ultrafiltration (ÉDUF) que par l'emploi des méthodes traditionnelles d'UF. Au cours de ces travaux, les premiers résultats ont démontré que l'utilisation de l'UF (seuil de coupure de 10 kDa, facteur de concentration 2X, pression trans-membranaire de 173 kPa) permettait de concentrer les peptides bioactifs, soit dans le perméat soit dans le rétentat, dépendamment de la bioactivité recherchée. En parallèle, cette étude a également permis de mettre en évidence que la configuration membranaire des diverses membranes disponibles commercialement, jouait un rôle important sur la séparation des peptides (comparaison des configurations de membrane spiralée et de membrane à fibres creuses). Ainsi, l'étude de la capacité des fractions collectées à moduler la captation du glucose a montré que seul le rétentat de la membrane spiralée (SWR) donne des résultats significativement améliorés. Selon l'analyse de la composition en acides aminés des différentes fractions, cette bioactivité serait due à une plus forte concentration en lysine. Par la suite, l'étude en ÉDUF des effets du pH sur les paramètres électrodialytiques (conductivité, taux de migration, résistance membranaire, etc.) ainsi que sur les bioactivités des fractions collectées (traitement de 4 h à 5 V avec des membranes d'un seuil de coupure de 10 kDa, pH 3, 6 et 9) a démontré l'impact du colmatage potentiel des membranes plus ou moins conséquent selon le pH sur la migration des peptides anioniques. Cependant, aucune des fractions collectées n'a démontré de capacités à stimuler la captation du glucose in vitro. Par la suite, il a pu être démontré qu'un traitement de 6 h à 50 V avec des membranes présentant un seuil de coupure de 100 kDa à pH 6 permettait l'isolement et la concentration de peptides dont la capacité à moduler la captation du glucose était de 22% supérieure à celle de l'hydrolysat complet et de 33% par rapport à celle induite par la fraction SWR. L'ensemble de ces travaux nous a donc permis de démontrer que l'hydrolyse enzymatique utilisée permettait de libérer des peptides bioactifs à partir des protéines du soya, mais également, que par l'optimisation des paramètres d'ÉDUF, il est possible d'isoler ces peptides bioactifs de manière plus sélective que par l'utilisation des techniques traditionnelles.
183

Cyclic fatty acid monomers of alpha-linolenic acid : isolation and separation of isomers, and effects of structural parameters on their oxidation

Mathew, Midhu 26 May 2021 (has links)
Les monomères cycliques d'acides gras (CFAM) provenant d'huiles riches en acide alphalinolénique (18:3; ALA) sont constitués de 16 isomères de structures cycliques à 5 et 6 atomes de carbone. Ils se forment lors de traitements thermiques des huiles, comme le raffinage et la friture. Conséquemment, les CFAMs se retrouvent dans l'alimentation humaine. La littérature scientifique rapporte les résultats de travaux sur les effets métaboliques des CFAMs dont le principal est la stéatose hépatique. Les isomères cycliques à 5 et à 6 carbones se forment simultanément lors du chauffage des huiles et l'obtention de l'un ou de l'autre, bien que possible par synthèse totale et par HPLC, est laborieuse et à faibles rendements, ce qui ajoute à la difficulté de la réalisation d'études métaboliques chez l'animal avec une seule de ces deux structures. Dans la première partie des travaux, présentés au chapitre II, nous nous sommes concentrés à mieux isoler les CFAMs de l'huile de lin, suivi d'une séparation supplémentaire en leurs principaux isomères CFAM-5 et CFAM-6 de l'acide linolénique, en utilisant une combinaison de chromatographie sur couche mince argentique, pour le développement de la méthode, et de chromatographie sur colonne, pour la production de fractions. Cinq fractions ont ainsi été récupérées à partir de la chromatographie argentique sur colonne avec le système de solvants hexane-acétate d'éthyleacide acétique dans les proportions volumétriques 120:30:1 . Les isomères des CFAMs de chacune des fractions ont ensuite été identifiés par GC-MS de leurs dérivés esters picolinyles. Les résultats indiquent que la fraction F-1 contient principalement des isomères CFAM-6. Deux isomères non rapportés dans la littérature, provisoirement identifiés comme des CFAM-5 conjugués, étaient aussi présents en faible quantité dans la fraction F-1. Une autre fraction, F-3, contenait des isomères de CFAMs uniquement à cycle de 5 atomes de carbones. Cette fraction comprenait aussi une faible quantité d'isomères de l'acide alpha-linolénique. La fraction intermédiaire F-2 contenait les deux types d'isomères des CFAMs. La littérature scientifique indique que les huiles végétales alimentaires peuvent s'oxyder et qu'elles peuvent causer des effets délétères sur la santé. Cependant, aucun travaux n'a porté sur l'oxydation des CFAM, les CFAM-Ox, ni sur leurs effets métaboliques potentiels. Pourtant, des similitudes structurelles peuvent être attendues entre celles de CFAM-Ox et celles de certaines phytoprostanes (PhytoPs) et isoprostanes (IsoPs), et potentiellement des activités biologiques analogues. Ainsi, l'objectif de la seconde partie des présents travaux, présentés au chapitre III, était d'étudier l'oxydation des CFAMs de l'acide alpha-linolénique. L'oxydation de ces CFAMs di-insaturés a été réalisée sous oxygène à des températures allant de 160 à 200 °C, sur des périodes de 8 heures. Les résultats indiquent qu'environ 60% des CFAM-5 sont oxydés au bout de 2 à 4 h et que leur oxydation se produit de manière significativement plus rapide que celle des CFAM-6, et à une vitesse qui s'approche de celle de l'oxydation de l'acide linoléique, acide gras également di-insaturé. Les différences observées entre les vitesses d'oxydation des CFAM-5 et des CFAM-6 sont probablement dues à la présence de positions bis-allyliques dans les structures CFAM-5, comme il s'en trouve dans l'acide linoléique, contrairement aux CFAM-6 qui contiennent des doubles liaisons isolées, séparées par deux atomes de carbone. Ces résultats suggèrent également que les niveaux rapportés dans la littérature scientifique des CFAMs dans les huiles de friture sont nécessairement sous-estimés car ils ne tiennent pas compte des CFAM-Ox. / Cyclic fatty acid monomers (CFAMs) from oils rich in alpha-linolenic acid (18: 3; ALA) consist of 16 isomers of 5 and 6 carbon ring structures. They are formed during thermal treatments of edible oils, such as refining and frying. Consequently, CFAMs are found in human food. The scientific literature reports the results of work on the metabolic effects of CFAMs, the main one of which is hepatic steatosis. The cyclic isomers of 5 and 6 carbons are formed simultaneously on heating oils and obtaining one or the other, although possible by total synthesis and HPLC, is laborious and in low yields. This contributes to the difficulty of performing metabolic studies in animals with just one of these two structures. In the first part of the work, presented in chapter II, we focused on better isolating the CFAMs from linseed oil, followed by an additional separation into their main isomers CFAM-5 and CFAM-6 of linolenic acid, using a combination of silver ion thin layer chromatography, for the development of the method, and column chromatography, for the production of fractions. Five fractions were thus recovered from silver ion column chromatography with the hexaneethyl acetate-acetic acid solvent system in volumetric proportions 120:30:1. The CFAM isomers of each of the fractions were then identified by GC-MS of their picolinic ester derivatives. The results indicate that fraction F-1 mainly contains CFAM-6 isomers. Two isomers not reported in the literature, tentatively identified as conjugated CFAM-5 isomers, were also present in small amounts in the F-1 fraction. Another fraction, F-3, contained isomers of CFAMs only with a ring of 5 carbon atoms. This fraction also contained a small amount of alpha-linolenic acid isomers. The intermediate fraction F-2 contained both types of CFAMs isomers. The scientific literature indicates that edible vegetable oils can oxidize and can cause deleterious health effects. However, no work has focused on the oxidation of CFAMs and their oxidation products, the CFAM-Ox, or their potential metabolic effects. However, structural similarities can be expected between those of CFAM-Ox and those of certain phytoprostanes (PhytoPs) and isoprostanes (IsoPs), and potentially similar biological activities. Thus, the objective of the second part of this work, presented in Chapter III, was to study the oxidation of CFAMs of alpha-linolenic acid. The oxidation of these diunsaturated CFAMs was carried out under oxygen at temperatures ranging from 160 to 200 °C, over periods of 8 hours. The results indicate that approximately 60% of CFAM-5 are oxidized after 2-4 h and that their oxidation occurs significantly faster than that of CFAM-6, and at a rate that approaches that of linoleic acid, also a di-unsaturated fatty acid. The differences observed between the oxidation rates of CFAM-5 and CFAM-6 are probably due to the presence of bis-allylic positions in CFAM-5 structures, as found in linoleic acid, unlike CFAM-6 which contain isolated double bonds separated by two carbon atoms. These results also suggest that the levels of CFAMs reported in frying oils in the scientific literature are necessarily underestimated because they do not take CFAM-Ox into account.
184

Développement et application d'un analyseur de mobilité ionique différentielle (FAIMS) à électrodes multiples en LDTD-MS/MS

Rochon, Jonathan 03 June 2024 (has links)
L'avancement de différentes sphères d'analyse moléculaire demande toujours un plus grand pouvoir d'identification de la matière. Par exemple, l'analyse en LDTD-MS peut être difficile lorsqu'un échantillon contient différentes molécules ayant la même masse (isobares & isomères). La mobilité ionique différentielle est une méthode de séparation de molécules ionisées qui s'avère être un outil additionnel dans le domaine de la spectrométrie de masse pour aider à repousser et/ou augmenter la spécificité et les limites de détection. Ce projet a eu pour but la conception et la caractérisation d'un instrument de mobilité ionique différentielle ayant une géométrie originale et qui est couplé à un système LDTD-MS/MS. L'objectif final est d'améliorer la résolution d'interférences de masses dans un système LDTD-MS/MS. Les configurations planes et coaxiales usuelles produisent la séparation des différentes molécules dans un plan perpendiculaire à l'axe de propagation et nécessitent deux électrodes pour y parvenir. Le concept original mis de l'avant dans ce travail sépare les molécules parallèlement à l'axe de propagation. Toutefois, ceci nécessite l'utilisation d'au moins trois électrodes pour y parvenir plutôt que 2 électrodes pour les configurations planes ou coaxiales. Cette approche a été prise dans l'optique de prolonger le parcours des ions dans les conditions optimales de séparation, tout en limitant les pertes par diffusion. Des simulations numériques ont été réalisées pour concevoir et caractériser une configuration à électrodes multiples. La configuration proposée produit la séparation caractéristique des FAIMS et DMS dans deux régions de dérive distinctes. Ce principe de fonctionnement nécessite des tensions de compensation indépendantes sur la première et la troisième électrodes. La fonction asymétrique (tension de dispersion) est appliquée sur la seconde électrode. Selon la polarité de la tension de dispersion, chaque région bloquera plus facilement des ions ayant un différentiel de mobilité ionique soit positif (∆K+) ou négatif (∆K-). Le mécanisme de séparation est différent de ce qui est réalisé lorsque la séparation est perpendiculaire à l'axe de propagation. Ainsi, un effort particulier a été mis sur la description et l'interprétation des courbes de transmission obtenues. Les concepts de résolution et de pouvoir de résolution, nécessaires à l'évaluation de la performance instrumentale, ont du être redéfinis pour pouvoir s'appliquer aux résultats obtenus. Un montage expérimental empruntant l'électronique d'un FAIMS commercial a été réalisé pour expérimenter la configuration novatrice. Les performances instrumentales ont été évaluées sous deux aspects : la séparation ciblée et la filtration d'interférences non ciblées. Des phtalates ayant des structures chimiques similaires ont été infusés et séparés par l'instrument. Les observations expérimentales concordent avec les résultats obtenus en simulation. Le mécanisme de séparation fonctionne tel que décrit théoriquement. La quantification de la quetiapine dans le plasma est limitée par un interférent sur la transition la plus sensible. Une courbe de calibration a comparé la limite de quantification d'un système LDTD-MS/MS et LDTD-FAIMS-MS/MS. La séparation de cet interférent non-ciblé a permis d'abaisser la limite de quantification d'un facteur 10 par rapport au système LDTD-MS/MS. Cette limite de quantification s'avère à un niveau qui plus bas que ce qui est répertorié dans littérature. / The advancement of different spheres of molecular analysis always requires greater power to identify the material. For example, LDTD-MS analysis can be difficult when a sample contains different molecules with the same mass (isobars & isomers). Differential ion mobility is a method for separating ionized molecules that is proving to be an additional tool in the field of mass spectrometry to help increase specificity and detection limits. The aim of this project was to design and characterize a differential ion mobility instrument with an original geometry that is coupled to an LDTD-MS/MS system. The final objective is to improve the resolution of mass interferences in an LDTD-MS/MS system. The usual planar and coaxial configurations produce the separation of different molecules in a plane perpendicular to the propagation axis and require two electrodes to achieve this. The original concept put forward in this work separates the molecules parallel to the propagation axis. However, this requires the use of at least three electrodes to achieve this rather than 2 electrodes for planar or coaxial configurations. This approach was taken in order to extend the ion path under optimal separation conditions, while limiting diffusion losses. Numerical simulations were performed to design and characterize a multiple electrode configuration. The proposed configuration produces the characteristic separation of FAIMS and DMS in two distinct drift regions. This operating principle requires independent compensation voltages on the first and third electrodes. The asymmetric function (dispersion voltage) is applied on the second electrode. Depending on the polarity of the dispersion voltage, each region will more easily block ions with either a positive (∆K+) or negative (∆K-) ion mobility differential. The separation mechanism is different from what is achieved when the separation is perpendicular to the propagation axis. Thus, a particular effort has been put on the description and interpretation of the transmission curves obtained. The concepts of resolution and resolving power, necessary for the evaluation of the instrumental performance, had to be redefined in order to be applied to the obtained results. An experimental set-up borrowing the electronics of a commercial FAIMS has been realized to experiment the innovative configuration. The instrumental performances were evaluated under two aspects: targeted separation and filtration of untargeted interferences. Phthalates with similar chemical structures were infused and separated by the instrument. The experimental observations are in agreement with the results obtained in simulation. The separation mechanism works as theoretically described. Quantification of quetiapine in plasma is limited by an interferent on the most sensitive transition. A calibration curve compared the limit of quantification of an LDTD-MS/MS and LDTD-FAIMS-MS/MS system. The separation of this untargeted interferent lowered the limit of quantification by an order of 10 compared to the LDTD-MS/MS system. This limit of quantification was found to be at a level that is lower than what is reported in the literature.
185

L'adaptation psychologique des adolescents à la suite d'une séparation parentale : contribution des expériences adverses à l'enfance

Chabot, Sarah 20 March 2024 (has links)
Titre de l'écran-titre (visionné le 18 mars 2024) / La recherche considère que la séparation parentale est l'un des événement les plus stressants dans la vie des enfants touchés, avec des répercussions qui se font sentir tout au long de leur vie (Stadelmann et al., 2010). Les recherches s'entendent pour dire que la séparation des parents est associée au risque de développement de comportements extériorisés et intériorisés à l'adolescence. Toutefois, peu d'études se sont penchées sur les effets de la séparation parentale dans le développement de traits limites. Par ailleurs, peu d'étude ont contrôlés pour d'autres formes de traumatismes, alors que de plus en plus de preuves démontrent que diverses formes de traumas chez les enfants coexistent souvent plutôt que de se produire de façon indépendante. Ainsi, la présente étude vise à explorer les liens d'associations entre des expériences adverses vécues dans l'enfance, notamment la séparation parentale, et l'adaptation psychologique des adolescentes et adolescents (c.-à-d. les comportements internalisés, les comportements externalisés et les traits limites), en tenant compte du genre. Des questionnaires ont été complétés par 110 adolescents âgés de 12 à 22 ans recrutés dans la population, plus précisément dans les écoles secondaires de la ville de Québec. Les résultats principaux de cette étude indiquent qu'après avoir contrôlé pour les autres formes de traumatismes, tels que l'abus physique, l'abus sexuel ainsi que la négligence et l'antipathie parentale, il n'y a pas de différence significative dans le développement de difficultés psychologiques entre les enfants de parents séparés et ceux de parents non séparés. Cependant, il est important de noter que les comportements externalisés sont plus fréquents chez les adolescents qui vivent avec une mère non séparée et qui font face à de l'antipathie et de la négligence de sa part. Cela suggère que l'antipathie et la négligence maternelle, plutôt que la simple séparation parentale, peuvent contribuer davantage aux comportements externalisés chez les enfants.
186

Stratégies analytiques pour l'extraction séquencée du Th, U, Ra, Pb et Po dans des matrices environnementales

Dalencourt, Claire 15 October 2019 (has links)
La présence naturelle de la radioactivité dans les rejets des industries, notamment minières, soulève des enjeux en termes de gestion et de réutilisation. La teneur en radioéléments permet d’établir le potentiel radioactif, essentiel pour attester de leur innocuité, ouvrant ainsi des voies de valorisation. La quantification des principaux éléments des chaînes de désintégration du thorium et de l’uranium, principales causes naturelles de la radioactivité, permet de prédire le potentiel radioactif. Dans le cas des résidus miniers, les méthodes existantes de quantification ne sont pas toujours fiables, car l’incertitude analytique qu’elles engendrent ne permet pas toujours de statuer quant au respect des limites gouvernementales. Afin de pallier ce problème, il est nécessaire de développer des méthodes rapides, précises et robustes afin d’analyser adéquatement ces matrices complexes. L’objectif et l’innovation de cette thèse résident dans le développement d’une méthode unique combinant plusieurs résines de manière séquencée afin d’extraire sélectivement le thorium, l’uranium, le radium, le plomb et le polonium. L’individualisation des résines après le chargement de l’échantillon permet la séparation des analytes, soit les cinq éléments d’intérêt, dans des fractions distinctes. Leur séparation, notamment des éléments interférents, rend leur analyse possible sur des instruments sensibles, tels que la spectrométrie alpha ou la spectrométrie de masse couplée au plasma inductif. Afin de garantir la fiabilité de l’analyse, une attention particulière est également portée sur la mise en solution des analytes de manière totale. Ainsi, cette thèse propose un complément aux techniques actuelles, telle que la spectrométrie gamma, pour établir un diagnostic juste et précis de la radioactivité naturelle, que ce soit pour une application industrielle ou en institut de recherche. Pour accompagner le lecteur, une partie théorique sera consacrée aux propriétés physiques et chimiques des éléments d’intérêt. De même, l’ensemble des méthodologies permettant leur quantification sera détaillé afin de comprendre tous les tenants et aboutissants de cette thèse. / Natural radioactivity is ubiquitous and reported in industrial wastes, such as mining residues. Its presence raises the issue of the management and the sustainability of such wastes. The content in radioactive elements allows to establish the radioactive potential of the residues, necessary to demonstrate their safety for an eventual revalorization. The quantification of the main elements of the thorium and uranium decay series, mainly responsible of natural radioactivity, allows to predict the radioactive potential. In the case of mining residues, current methodologies are not always reliable due to analytical uncertainties, often flirting with governmental limitations. To overcome this issue, new methods must be developed to handle complex matrices as well as being fast, precise and robust. The aim of this thesis is to develop a unique innovative method that combine several sequential resins to selectively extract thorium, uranium, radium, lead and polonium. The targeted analyte can be recovered after selective elution on a single resin. The segregation of the elements from interfering elements originating from the matrix allows their precise measurement on instruments such as alpha spectrometry or inductively coupled plasma mass spectrometry. To ensure the reliability of the analysis, total sample dissolution techniques have also been investigated. This thesis brings a valuable complement to current techniques such as gamma spectrometry, to screen natural radioactivity with accuracy and precision. Thus, the proposed technique could be applied in both industrial support laboratories and research laboratories. To guide the reader, a theorical part dealing with the chemical and physical properties of elements of interest will be provided. In addition, standard methodologies on their quantification will also be detailed in order demonstrate the novelty of the work presented in this thesis.
187

Optimisation des procédés de concentration de la lizardite et de l'antigorite des résidus miniers de chrysotile

Kabombo, Dieudonné 25 July 2018 (has links)
La nouvelle loi canadienne sur l’amiante chrysotile décrétée par le gouvernement fédéral devrait entrer en vigueur au courant de l’année 2019 et les nouvelles normes environnementales qui en découleront nous forcent déjà à trouver des solutions pour réduire de façon significative l’impact environnemental et de revaloriser des résidus d’exploitation du chrysotile. Une des façons de réduire cet impact environnemental et revaloriser ce résidu consiste à concentrer la lizardite et l’antigorite comme matériaux générateurs de magnésium (Mg) et éliminer le chrysotile (cancérigène). Ces minéraux sont abondants dans les résidus miniers d’exploitation du chrysotile de l’ancienne mine Carey Canadian à East-Broughton dans le sud du Québec. La présente étude propose donc une revue des procédés de séparation physique des phases minérales serpentiniques et une étude détaillée sur la séparation gravimétrique par voie humide (hydrocyclonage/décantation) pour différentes classes granulométriques et une étape finale de séparation magnétique à sec pour l’extraction des minéraux magnétiques (magnétite) dans le concentré de la décantation. Les propriétés physiques, chimiques et minéralogiques du résidu initial ont été obtenues par tamisage grossier, par analyse de densité et surface spécifique, par fluorescence aux rayons X, par spectroscopie RAMAN, par MEB-EDS et par DRX. Les résultats les plus importants de cette étude sont qu’il est possible d’éliminer le chrysotile, sous forme de surverse, par hydrocyclonage en régime dilué (30% solides dans la pulpe) tout en concentrant la lizardite et l’antigorite (sousverse) avec des récupérations en Mg de l’ordre de 70 à 80 % en poids de Mg en sousverse. La séparation liquide-solide a été effectuée à 5 % de solides dans la pulpe et a permis d’augmenter la pureté du concentré d’hydrocyclonage (sousverse) avec des récupérations en Mg dans la sousverse variant entre 36 et 70 % partant des fines particules vers les grossières. La séparation magnétique a permis d’augmenter la pureté du concentré de décantation (sousverse) par l’extraction du fer. Ce qui a conduit à des récupérations croissantes en fer de 30 à 60 % à partir de particules grossières vers les fines. Les rapports Si/Mg et Fe/Si en fonction de la taille des particules pour les fractions non-magnétiques (concentrés) ont également été examinés dans une tentative d’estimation du fer résiduel présent par substitution intra-réseau Fe-Mg et Fe-Si dans les concentrés non-magnétiques. Mots clés: Hydrocyclone, Décantation, Séparation magnétique, Chrysotile, Lizardite, Antigorite. / Canada's new law on chrysotile asbestos is expected to come into force in 2019 by the federal government, and the resulting new environmental standards are already forcing us to find solutions to significantly reduce the environmental impact and revalorize chrysotile mining residues. One of the ways to reduce this environmental impact and enhance this residue is to concentrate lizardite and antigorite as magnesium (Mg) generating materials and eliminate chrysotile (carcinogenic). These minerals are abundant in the chrysotile mining tailings of the former Carey Canadian mine in East-Broughton in southern Quebec. The present study therefore proposes a review of the physical separation processes of serpentine mineral phases and a detailed study on wet gravimetric separation (hydrocycloning / decantation) for different granulometric classes and a final dry magnetic separation step for the extraction of minerals magnetic minerals (magnetite) in the concentrate of the decantation. The physical, chemical and mineralogical properties of the initial residue were obtained by coarse sieving, density and surface area analysis, X-ray fluorescence, RAMAN spectroscopy, SEM-EDS and XRD spectroscopy. The most important results of this study are that it is possible to eliminate chrysotile, in the form of overflow product, by dilute hydrocycloning (30% solids in the pulp) while concentrating lizardite and antigorite (underflow) with recoveries in Mg of the order of 70 to 80% by weight of Mg underflow. The liquid-solid separation was carried out at 5% solids in the pulp and made it possible to increase the purity of the hydrocyclone concentrate (underflow) with Mg recoveries in the underflow varying between 36 and 70% starting from the fine particles to the coarse ones. Magnetic separation made it possible to increase the purity of the settling concentrate (underflow) by extracting iron. This led to increasing recoveries of iron from 30 to 60% from coarse particles to fine ones. Si / Mg and Fe / Si ratios as a function of particle size for non-magnetic fractions (concentrates) were also examined in an attempt to estimate the residual iron present by intra-network substitution Fe-Mg and Fe- Si in non-magnetic concentrates. Keywords: Hydrocyclone, Decantation, Magnetic separation, Chrysotile, Lizardite, Antigorite.
188

Développement des membranes pour la séparation in-situ de l'eau à hautes températures

Lafleur, Matthieu 12 October 2018 (has links)
La libération de dioxyde de carbone (CO₂) dans l’atmosphère est de plus en plus alarmante et nécessite que des actions soient posées de toute urgence afin de réduire les impacts. On compte parmi celles-ci la conversion du CO₂ en produits à valeur ajoutées, par exemple en diméthyléther (DME), pouvant être utilisé comme vecteur d’énergie propre. Dans le but de favoriser l’hydrogénation catalytique du CO₂, il a été proposé de faire la séparation in-situ de l’eau coproduite lors de la réaction, ce qui est nécessaire à la production rentable du DME. Malgré les nombreuses recherches faites sur la séparation de l’eau in-situ d’un milieu réactionnel, très peu d’entre elles semblent en mesure d’obtenir de bons résultats pour des températures élevées (≈250 °C), requises pour la conversion catalytique du CO₂. Une solution intéressante semble être la membrane zéolitique permsélective à l’eau d’hydroxy-sodalite (hydroxy-SOD). Selon la littérature, cette zéolite est en mesure de résister aux dures conditions de réaction tout en étant capable de séparer l’eau des autres réactifs avec une excellente sélectivité. Cependant, il semble impossible de reproduire ces résultats lorsqu’elle est synthétisée sous forme de membrane avec les techniques conventionnelles. C’est pourquoi le présent projet de maîtrise porte sur le développement d’une nouvelle technique de synthèse de membranes d’hydroxy-SOD par « pore-plugging ». Elle consiste à insérer mécaniquement des germes d’hydroxy-SOD à un endroit précis du support sélectionné, pour ensuite les faire croitre par synthèse hydrothermale jusqu’à ce que les pores du support se bloquent. Dans le but d’optimiser la technique par « pore-plugging », une série de paramètres ont été examinés et optimisés tant au niveau de la synthèse des germes que celle des membranes. Cela a mené à l’élaboration d’un protocole permettant la production de membrane d’hydroxy-SOD ayant une sélectivité (SH2O/H2) de 1.4 et une perméance H2O de 1.26 x 10⁻⁷ mol Pa⁻¹ m⁻² s⁻¹ à 250 °C. / The release of carbon dioxide gas (CO₂) is becoming increasingly alarming and requires that concrete actions get implemented as fast as possible in order to reduce future impacts. One of the solutions could be the catalytic conversion of CO₂ into value-added products like dimethyl ether (DME), which can be used as a clean energy vector. Unfortunately, the direct catalytic hydrogenation of CO₂ isn’t thermodynamically favoured if done in a conventional reactor, because of the coproduced water. That’s why this master thesis will work on an in-situ method to remove the produced water from the reactor. This upgrade is essential for an economically viable process to synthesize DME from CO₂. Despite extensive research in the field of in-situ removal of water, very few seem to be able to achieve promising results at the high temperatures required for CO₂ conversion (≈250˚C). An interesting solution seems to lie in a water permselective zeolite membrane made of hydroxy-sodalite (hydroxy-SOD). According to the literature, that zeolite would be capable of withstanding the harsh reaction conditions while being able to separate water with excellent selectivity. However, when made into a membrane, their water selectivity doesn’t seem to reproduce well. This is caused by defects in the synthesized membrane that are cause by less than optimal conventional synthesis methods. That is why this master’s project address the problem by the development of a new membrane synthesis technique for hydroxy-SOD by ‘’pore-plugging’’, which attempt to prevent membrane defects. This technique consists in the mechanical insertion of engineered hydroxy-SOD seeds at a precise location of asymmetric ceramic support. These seeds are then grown by subsequent hydrothermal synthesis up to the point that the smaller pores of the support are completely filled. That results in a really thin composite membrane of hydroxy-SOD zeolite having minimal number of defects. In order to optimize the ‘’pore-plugging’’ technique, a series of synthesis parameters have been examined and improved for both the seeds and the membrane production. This led to the development of a protocol allowing the synthesis of a hydroxy-SOD membrane having water selectivity (SH2O/H2) of 1.4 and a permeance H2O of 1.26 x 10⁻⁷ mol Pa⁻¹ m⁻² s⁻¹ at 250 °C.
189

Séparation des éléments de terres rares par extraction par solvant : estimation des constantes d'équilibre d'extraction pour la simulation du procédé

Turgeon, Keven 24 April 2018 (has links)
Ce mémoire porte sur la séparation des éléments de terres rares (ETR) par le procédé d’extraction par solvant. L’objectif est de développer un diagramme d’écoulement permettant la séparation des ETR présents dans une solution de lixiviation d’un minerai d’ETR. Pour ce faire, un simulateur permettant de prédire la distribution des ETR dans les phases d’un mélangeur-décanteur qui sont à l’équilibre chimique a été développé. Ce simulateur utilise les constantes d’équilibre chimique de la réaction de transfert entre phases de chaque élément présent en solution. Une méthode d’analyse juste et précise des ETR avec un spectromètre à émission atomique à plasma induit par micro-onde (MP-AES) a été développée. Des tests d’extraction par solvant sont réalisés en laboratoire et les données sont traitées afin de produire des constantes d’équilibre d’extraction qui sont utilisées en simulation. Une étude de la cinétique des extractions a permis de déterminer que trente secondes d’agitation dans une ampoule à décanter sont suffisantes pour atteindre l’équilibre chimique dans le cas des extracteurs utilisés. Une méthode novatrice de réconciliation de donnée permettant de balancer les résultats des tests d’extraction est appliquée aux données brutes des tests expérimentaux. Cela permet d’estimer des constantes d’équilibre d’extraction plus reproductibles que celles obtenues par les méthodes classiques de traitement de données de tests d’extraction. Le simulateur prédit les concentrations à l’équilibre dans les phases aqueuses et organiques pour une ou plusieurs extractions consécutives. Un diagramme d’écoulement permettant la séparation des ETR en deux sous-groupes (ETR légers et SEG avec ETR lourds) est développé pour le traitement d’une solution réelle d’ETR produite par le traitement du minerai de terres rares de la mine Niobec. Le diagramme d’écoulement développé a été simulé et testé expérimentalement. Les résultats expérimentaux obtenus sont similaires aux prédictions du simulateur pour l’ensemble du procédé, ce qui tend à démontrer la validité de l’approche proposée pour l’estimation des constantes d’équilibre et de l’approche utilisée pour la simulation du procédé d’extraction par solvant. / This thesis discusses the separation of rare earth elements (REE) using the solvent extraction process. The objective is to develop a flow sheet allowing the separation of the REE present in a leaching solution of REE ore. To achieve this, a simulator to predict the distribution of REE in the phases of a mixer-settler that are in chemical equilibrium was developed. This simulator uses the chemical equilibrium constants of each element present in solution. A method for accurate and precise analysis of REE with a microwave-induced plasma atomic emission spectrometer (MP-AES) was also developed. Solvent extraction tests are performed in the laboratory and the data is processed to produce extraction equilibrium constants that are used in the simulation. A study of the kinetics of the extraction process shows that thirty seconds of agitation in a separating funnel are sufficient to reach the chemical equilibrium in the case of the extractors used. An innovative data reconciliation method for balancing the extraction test results and estimating the equilibrium constants for the species transferred between the phases is applied to the raw data of experimental tests. It is shown that the proposed method provides more reproducible extraction equilibrium constants than standard data processing methods. A simulator based on the estimated equilibrium constants has then been written to predict the equilibrium concentrations in the phases of one or several consecutive extractions. A flow sheet allowing the separation of REE into two subgroups (light REE and SEG with heavy REE) is developed. The flow sheet consisting of three extraction steps, three scrubbing stages and two stripping stages is simulated and tested at a laboratory scale on a leaching solution of REE ore. The experimental results obtained are similar to the predictions of the simulator for the whole process showing the validity of the simulation method based on the use of the equilibrium constants.
190

Separation and analysis of Sr-90 and Zr-90 for nuclear forensic applications

Zattoni, Ana Paula 23 April 2018 (has links)
Le présent travail porte sur le développement technologique pour déterminer l'âge des sources de radiostrontium à travers du rapport [Zr-90]/[Sr-90], en utilisant les techniques de spectrométrie de masse et scintillation liquide pour quantifier les deux isotopes. Parce que Sr-90 et Zr-90 sont des interférences isobariques en spectrométrie de masse, une séparation radiochimique est nécessaire pour isoler du Zr-90 avant son analyse. Parmi quatre résines commerciales, la résine DGA a fourni la meilleure performance pour isoler le Zr-90 du Sr-90. Des récupérations supérieures à 99% pour le Zr-90 ont été obtenues. La résine DGA était aussi l'approche la plus rapide et la plus efficace pour éliminer les interférences isobariques du Sr-90 et aussi de l’Y-90 potentiellement présents dans des échantillons contenant des niveaux élevés de radioactivité. Des expériences impliquant l’utilisation d’une cellule de collision pour éliminer des interférences isobariques ont fourni des facteurs de décontamination insuffisants pour des applications en criminalistique nucléaire. / In this work, a technological development to determine the age of radioactive strontium sources through the [Zr-90]/[Sr-90] ratio using mass spectrometry and liquid scintillation to quantify both isotopes is presented. Because Sr-90 and Zr-90 are isobaric interferences in mass spectrometry, a radiochemical separation to isolate Zr-90 has been shown to be mandatory prior to analysis. Four commercial resins (AG50W-X9, Dowex1-X8, Sr and DGA resins) were tested to isolate Zr-90 from Sr-90. Best performance was observed for the DGA resin, including recoveries higher than 99% for Zr-90. DGA has also demonstrated to be the faster approach and the most efficient not only to eliminate isobaric interferences from Sr-90, but also from Y-90, potentially present in samples containing high levels of radioactivity. Experiments using a collision cell to eliminate isobaric interferences in a triple quadrupole mass spectrometer (ICP-QQQMS) have also been carried out, but results have demonstrated insufficient decontamination factors for nuclear forensic applications.

Page generated in 0.0846 seconds