• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 138
  • 28
  • 6
  • 6
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 203
  • 203
  • 73
  • 62
  • 41
  • 41
  • 39
  • 29
  • 26
  • 23
  • 23
  • 23
  • 23
  • 22
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Estudo da permeabilidade dos solos de fundação do aterro de resíduos sólidos urbanos de Bauru

Jesus, Lucas Scarpanti de [UNESP] 22 June 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-06-22Bitstream added on 2014-06-13T19:33:41Z : No. of bitstreams: 1 jesus_ls_me_bauru_prot.pdf: 14176477 bytes, checksum: 1b3c89c43f22dd709d61a808988b4abe (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Para a avaliação da contaminação dos solos em áreas de disposição de resíduos sólidos é fundamental conhecer a permeabilidade desses solos, quantificada pela condutividade hidráulica (k). Pesquisas anteriores avaliaram a contaminação que ocorre no Aterro de Resíduos Sólidos Urbanos de Bauru/SP, e sugerem valores de K para os solos que ocorrem no local. O objetivo desta pesquisa é dar continuidade aos estudos de investigação neste aterro, buscando encontrar valores representativos de K para os diferentes tipos de solos que ocorrem na área, empregando técnicas de ensaios em campo e laboratório. No laboratório foram realizados ensaios de condutividade hidráulica em permeâmetros de parede rígida e flexível a carga variável e constante em amostras indeformadas. Em campo, foram conduzidos ensaios de recuperação em poços de monitoramento (Slug Test), zona saturada, e ensaios de condutividade com o permeâmetro de Guelph na zona não saturada. Quatro tipos de solos são encontrados na região do aterro, coluvião, aluvião e residual de arenito. No laboratório, utilizando permeâmetros de parede rígida, foi possível encontrar valores médios de K para o colúvio e o alúvio, sendo estes, respectivamente, k=2,6x10-6, 2,0x10-5 m/s. Paro o solo residual e para o arenito utilizou-se de permeâmetros de parede flexível para a realização dos ensaios, com saturação por contra pressão, obtendo-se os valores de k=1,2x10-7 e 3,3x10-8 m/s, respectivamente. No campo para o solo residual encontraram-se valores de K de 3,7x10-7 m/s na zona saturada e de 3,4x10-7 e 1,3x10-7 m/s para a zona não saturada. No solo coluvionar obteve-se um valor de K de 5,3x10 na zona não saturada. No aluvião encontrou-se grande variação de K com a profundidade, obtendo-se um valor médio para a zona saturada d 7,9x10-7 m/s. Já, para... / In the assessment of soil contamination caused by solid waste disposal sites it is essential to investigate the soils permeability, quantified by the hydraulic conductivity (k). Previous research has assessed the contamination that occurs in the Brazil/SP Municipal Solid Waste disposal site, and suggested K values for the soils that occur at this site. The objective of this research is to continue the investigation studeies at the site, aiming to find representative K values for all the different soil types that occur in the area, using both laboratory and in situ testing techniques. Laboratory hydraulic conductivity tests were performed in rigid and flexibe wall permeameters by variable and constant head on undisturbed soil samples. Slug Tests in monitoring wells (saturated zone) and hidraulic conductivity tests with the Guelph permameter (unsaturated zone) were carried out in situ. Four types of soils are found in the site: colluvium, alluvium, sandstone and residual sandstone. The average K values for the colluviam and alluvium determined in the rigid wall permeameter were qual to 2.6x10-6 and equal to 2.0x10-5 m/s, respectively. The flexibe wall permeameter was used to carry out lab tests in the residual soil and sandstore, using backpressure saturation, obtaining the K values equal to 1.2 x 10-7 and equal to 3.3x10-8 m/s, respectively. A K value of 3.7x10-7 m/s for the residual soil was determined in situ in the saturated zone and K values of 3.4x10-7 and 1.3x10-7 m/s were determined in the unsaturated zone. For the colluvium soil, a K value of 5.3x10-6 m/s in the unsatured zone was determined. The K values varied with depth in the Alluvium, and the average valeu for the saturated zone was 7.9x10-7 m/s. It was not possible to carry out in situ tests in the residual soil. The representative K value were equal to 5.3x10-6, 1.1x10-4 and 1.2x10-7... (Complete abstract click electronic access below)
182

Caracterização de impacto ambiental no solo em um aterro de pequeno porte

Bellezoni, Rodrigo Augusto [UNESP] 27 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-27Bitstream added on 2014-06-13T19:38:36Z : No. of bitstreams: 1 bellezoni_ra_me_bauru.pdf: 3031269 bytes, checksum: fb9929ec904e2ea3a2320a92f75db9df (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A disposição de resíduos sólidos no solo gera frequentes preocupações ambientais, sociais e de saúde pública. Os aterros sanitários de pequeno porte são uma alternativa sugerida por órgãos ambientais no Estado de SP para que pequenos municípios possam destinar seus resíduos de forma ambientalmente segura, a custos reduzidos. Esta pesquisa teve como objetivo avaliar, sob a análise de aspectos físicos e geofísicos, se este mecanismo possui capacidade em conter os líquidos percolados das colunas de resíduos, evitando riscos de contaminação no solo e águas subterrâneas. Para tanto, características físicas da área de influência do aterro foram determinadas com auxílio de mapas, assim como as características físicas foram determinadas através de ensaios padrão. O método da Eletrorresistividade foi empregado para caracterizar o solo em subsuperfície e estimar sua capacidade na atenuação de contaminantes. Os resultados mostraram o potencial de aplicação deste método, através da relação entre elevada carga iônica e baixa resistividade elétrica, definindo com clareza o limite das plumas de contaminantes. O chorume ocorre em grande parte das valas mais recentes, devido à etapa de decomposição. Valas antigas apresentaram tendência de aumento na resistividade, significando queda na geração de chorume, concomitante ao aumento do tempo de resistividade dos resíduos. Assim, a zona de influência dos resíduos limitou-se à 20 m da área de disposição no plano horizontal e até 8,5 em profundidade. As propriedades físico-químicas do solo argiloso local influenciaram o comportamento da pluma de contaminantes, visto a redução destas ao longo do tempo. Destacam-se o mineral de argila e a granulometria como os possíveis principais responsáveis pela atenuação natural dos contaminantes. Em alguns... / The disposal of solid waste in the soil often creates environmental, social and public health concerns. Small landfills are an alternative suggestion by environmental agencies in the State of São Paulo so small cities direct their waste in an environmentally safe manner, at costs. This research is aimed to evaluate, under the analysis of physical and geophysical concepts, if this mechanism has the capacity to contain lanchated liquid from the columns of waste, avoiding risks of contamination in soil and groundwater. Thus, physical characteristics of landfill catchment area were determined with the aid of maps, as well as the physical characteristics of the local soil were determined by standard assays. The Electrical Resistivity method was employed to characterize the subsoil and to estimate its ability to attenuate contaminants. The results showed the potential application of this method through the relationship between hhigh ionic charge and low resistivity, defining clearly the limits of contaminant plumes. Leachate occurs largely in the more recent dithes, due to the decomposition phase. Older ditches tended to increase in resistivity; it means decrease of leachate generation, as well the increase of waste time residence. Thus, the waste influence zone was limited to 10 m of the disposal area in the horizontal plane and up to 8.5 m in depth. The physicochemical properties of the clay soil spot have influenced the contaminants plume behavior, to reduce it along the time. Emphasizing this are the clay mineral and grain size held as possible primary accountable for natural attenuation of contaminants. At some ponts, it is estimated that the layer of unsaturated soil under the ditches be less that one meter, it does not comply the criteria for exemption of additional waterproofing, established in NBR 15.849:2010 Municipal solid waste... (Complete abstract click electronic access below)
183

Resistência à tração de um plástico mole em contato com lixiviado de RSU ao longo do tempo / Traction strength of a soft plastic contact MSW leachate over time

Feltrim, Fernanda 19 February 2016 (has links)
CAPES / A produção de resíduos sólidos urbanos (RSU) aumenta a cada dia em razão da associação de uma série de fatores, tais como crescimento da população, aumento do poder aquisitivo, facilidade de acesso aos bens de consumo, etc. Em consequência, o gerenciamento e a disposição final tornaram-se um grande problema a ser encarado onde, atualmente, um dos principais meios de destinação final dos RSU é o aterro sanitário. Otimizar sua vida útil devido à ausência de terrenos adequados para este fim, principalmente em grandes centros urbanos, e exigências mais rígidas de órgãos controladores e reguladores, tornou-se um dos principais focos dos gestores tanto municipais quanto estaduais. Uma das formas de melhorar o aproveitamento das áreas de disposição de RSU é o aumento da altura do aterro, porém, se não for realizado de forma correta pode ocasionar danos significativos para o meio ambiente e para a sociedade. A presença de materiais com propriedades semelhantes às fibras existentes na massa de resíduos sólidos, como plásticos e têxteis, promovem um acréscimo na resistência ao cisalhamento da massa de RSU depositada em aterros, porém, esses materiais vão sofrendo decomposição e alterando suas propriedades e, consequentemente, podendo ocasionar mudanças na resistência ao cisalhamento ao longo do tempo. Desta forma, o presente trabalho tem por objetivo avaliar a influência do lixiviado na resistência à força de tração do plástico mole e como objetivos específicos avaliar a influência largura, distância entre as distância entre as ancoragens e taxa de carregamento, nas trações resultantes; verificar se há variação do pH, demanda química de oxigênio (DQO), alcalinidade, ácidos voláteis, nitrogênio amoniacal e fósforo total presentes no lixiviado, ao longo do tempo e avaliar a estrutura e componentes do plástico mole com e sem imersão no lixiviado. Foram utilizadas sacolas plásticas de supermercado, cortadas em tiras de 0,5 e 1,0 cm de largura, estas ficaram em contato com o lixiviado coletado em um aterro sanitário da região metropolitana de Curitiba-PR, e em seguida foram submetidas aos ensaios de força de tração, a cada quinze dias, variando a distância entre as ancoragens (0 cm, 7 cm e 21 cm) e a taxa de carregamento de ensaio (1 mm.min-1 e 4 mm.min-1). O estudo permitiu verificar que os ensaios realizados com largura de 1 cm resultaram em força de tração superior àquelas realizadas com largura de 0,5 cm. A distância entre as ancoragens e taxa de carregamento de ensaio interferem significativamente nos valores de força de tração obtidos, sendo que ensaios realizados com taxa de carregamento de 4 mm.min-1 resultaram em força de tração superior. Quando se leva em consideração o tempo de contato, não foi possível chegar a uma conclusão definitiva, pois o tempo de contato foi relativamente pequeno. Com a análise de microscopia eletrônica de varredura (MEV) e espectroscopia de energia dispersiva (EDS) foi possível verificar que há deposição de sólidos nas tiras plásticas após imersão no lixiviado e que há deposição de diferentes componentes químicos nas tiras plásticas como o alumínio, por exemplo. / The production of municipal solid waste (MSW) increases every day because of the association of a number of factors such as population growth, increased purchasing power, facility of access to consumer goods, etc. Consequently, the management and disposal have become a major problem to be faced where currently one of the main means of disposal of MSW is the landfill. Optimize its useful life due to ausence of suitable land for this purpose, especially in large urban centers, exigencies stricter controllers and regulators; it has become a major focus of both municipal and state managers. One way to improve the use of MSW disposal sites is increasing embankment height, but if not done properly can cause significant damage to the environment and society. The presence of materials with similar properties to existing fibers in the mass of solid waste such as plastics and textiles, promote an increase in mass of the shear strength of MSW landfill, but these materials are undergoing decomposition and changing its properties, consequently, may cause changes in shear strength over time. Thus, this study aims to evaluate the influence of the leachate on the tensile strength of the soft plastic and specific objectives to assess the width, distance between anchors and speed the resulting pulls, check for variation of pH, chemical oxygen demand (COD), alkalinity, volatile fatty acids, ammonia, nitrogen and total phosphorus present in the leachate over time and to assess the structure and the soft plastic components with and without immersion in the leachate. Plastics grocery bags, cut into 0.5 to 1.0 cm wide strips were used. These were in contact with leachate collected in a landfill in the metropolitan region of Curitiba-PR, and then were sub- jected to tensile tests, every fifteen days, varying the distance between the anchors (0 cm, 7cm and 21 cm ) and the test speed (1 mm.min-1 and 4 mm.min-1) .The study showed that the tests performed with a width of 1 cm resulted in those made with superior traction width of 0.5 cm. The distance between the anchors and speed of test interfere significantly in tensile values, and tests performed at a speed of 4 mm.min-1 resulted in superior traction. When taking into account the contact time was not possible to reach a definitive conclusion as contact time was relatively low. With the analysis of scanning electronic microscopy (SEM) and energy dispersive spectroscopy (EDS) were unable to verify that there is deposition of solids in the plastic strips and that there are different chemical components present in the solid aluminum, for example.
184

Resistência à tração de um plástico mole em contato com lixiviado de RSU ao longo do tempo / Traction strength of a soft plastic contact MSW leachate over time

Feltrim, Fernanda 19 February 2016 (has links)
CAPES / A produção de resíduos sólidos urbanos (RSU) aumenta a cada dia em razão da associação de uma série de fatores, tais como crescimento da população, aumento do poder aquisitivo, facilidade de acesso aos bens de consumo, etc. Em consequência, o gerenciamento e a disposição final tornaram-se um grande problema a ser encarado onde, atualmente, um dos principais meios de destinação final dos RSU é o aterro sanitário. Otimizar sua vida útil devido à ausência de terrenos adequados para este fim, principalmente em grandes centros urbanos, e exigências mais rígidas de órgãos controladores e reguladores, tornou-se um dos principais focos dos gestores tanto municipais quanto estaduais. Uma das formas de melhorar o aproveitamento das áreas de disposição de RSU é o aumento da altura do aterro, porém, se não for realizado de forma correta pode ocasionar danos significativos para o meio ambiente e para a sociedade. A presença de materiais com propriedades semelhantes às fibras existentes na massa de resíduos sólidos, como plásticos e têxteis, promovem um acréscimo na resistência ao cisalhamento da massa de RSU depositada em aterros, porém, esses materiais vão sofrendo decomposição e alterando suas propriedades e, consequentemente, podendo ocasionar mudanças na resistência ao cisalhamento ao longo do tempo. Desta forma, o presente trabalho tem por objetivo avaliar a influência do lixiviado na resistência à força de tração do plástico mole e como objetivos específicos avaliar a influência largura, distância entre as distância entre as ancoragens e taxa de carregamento, nas trações resultantes; verificar se há variação do pH, demanda química de oxigênio (DQO), alcalinidade, ácidos voláteis, nitrogênio amoniacal e fósforo total presentes no lixiviado, ao longo do tempo e avaliar a estrutura e componentes do plástico mole com e sem imersão no lixiviado. Foram utilizadas sacolas plásticas de supermercado, cortadas em tiras de 0,5 e 1,0 cm de largura, estas ficaram em contato com o lixiviado coletado em um aterro sanitário da região metropolitana de Curitiba-PR, e em seguida foram submetidas aos ensaios de força de tração, a cada quinze dias, variando a distância entre as ancoragens (0 cm, 7 cm e 21 cm) e a taxa de carregamento de ensaio (1 mm.min-1 e 4 mm.min-1). O estudo permitiu verificar que os ensaios realizados com largura de 1 cm resultaram em força de tração superior àquelas realizadas com largura de 0,5 cm. A distância entre as ancoragens e taxa de carregamento de ensaio interferem significativamente nos valores de força de tração obtidos, sendo que ensaios realizados com taxa de carregamento de 4 mm.min-1 resultaram em força de tração superior. Quando se leva em consideração o tempo de contato, não foi possível chegar a uma conclusão definitiva, pois o tempo de contato foi relativamente pequeno. Com a análise de microscopia eletrônica de varredura (MEV) e espectroscopia de energia dispersiva (EDS) foi possível verificar que há deposição de sólidos nas tiras plásticas após imersão no lixiviado e que há deposição de diferentes componentes químicos nas tiras plásticas como o alumínio, por exemplo. / The production of municipal solid waste (MSW) increases every day because of the association of a number of factors such as population growth, increased purchasing power, facility of access to consumer goods, etc. Consequently, the management and disposal have become a major problem to be faced where currently one of the main means of disposal of MSW is the landfill. Optimize its useful life due to ausence of suitable land for this purpose, especially in large urban centers, exigencies stricter controllers and regulators; it has become a major focus of both municipal and state managers. One way to improve the use of MSW disposal sites is increasing embankment height, but if not done properly can cause significant damage to the environment and society. The presence of materials with similar properties to existing fibers in the mass of solid waste such as plastics and textiles, promote an increase in mass of the shear strength of MSW landfill, but these materials are undergoing decomposition and changing its properties, consequently, may cause changes in shear strength over time. Thus, this study aims to evaluate the influence of the leachate on the tensile strength of the soft plastic and specific objectives to assess the width, distance between anchors and speed the resulting pulls, check for variation of pH, chemical oxygen demand (COD), alkalinity, volatile fatty acids, ammonia, nitrogen and total phosphorus present in the leachate over time and to assess the structure and the soft plastic components with and without immersion in the leachate. Plastics grocery bags, cut into 0.5 to 1.0 cm wide strips were used. These were in contact with leachate collected in a landfill in the metropolitan region of Curitiba-PR, and then were sub- jected to tensile tests, every fifteen days, varying the distance between the anchors (0 cm, 7cm and 21 cm ) and the test speed (1 mm.min-1 and 4 mm.min-1) .The study showed that the tests performed with a width of 1 cm resulted in those made with superior traction width of 0.5 cm. The distance between the anchors and speed of test interfere significantly in tensile values, and tests performed at a speed of 4 mm.min-1 resulted in superior traction. When taking into account the contact time was not possible to reach a definitive conclusion as contact time was relatively low. With the analysis of scanning electronic microscopy (SEM) and energy dispersive spectroscopy (EDS) were unable to verify that there is deposition of solids in the plastic strips and that there are different chemical components present in the solid aluminum, for example.
185

An?lise comparativa dos m?todos de fatores ponderados na sele??o de ?reas para aterros sanit?rios

Muniz, C?tia Araujo Lopes 14 June 2013 (has links)
Made available in DSpace on 2014-12-17T14:53:10Z (GMT). No. of bitstreams: 1 CatiaALM_DISSERT.pdf: 1287414 bytes, checksum: 24b6c90e93ec6846afbd8ee3d7271dfc (MD5) Previous issue date: 2013-06-14 / This study presents a comparative analysis of methodologies about weighted factors considered in the selection of areas for deployment of Sanitary Landfills, applying the methodologies of classification criteria with scoring bands Gomes, Coelho, Erba & Veronez (2000); Waquil et al, 2000. That means, we have the Scoring System used by Union of Municipalities of Bahia and the Quality Index Landfill Waste (IQR) which are applyed for this study in Massaranduba Sanitary Landfill located in the municipality of Cear? Mirim /RN, northeastern of Brazil. The study was conducted in order to classify the methodologies and to give support for future studies on environmental management segment, with main goal to propose suited methodologies which allow safety and rigor during the selection, deployment and management of sanitary landfill, in the Brazilian municipalities, in order to help them in the process to extinction of their dumps, in according of Brazilian Nacional Plan of Solid Waste. During this investigation we have studied the characteristics of the site as morphological, hydrogeological, environmental and socio-economic to permit the installation. We consider important to mention the need of deployment from Rio Grande do Norte State Secretary of Environment and Water (SEMARH), Institute of Sustainable Development and Environment of RN (IDEMA), as well, from Federal and Municipal Governments a public policies for the integrated management of urban solid waste that address environmental preservation and improvement of health conditions of the population of the Rio Grande do Norte / Apresenta-se neste trabalho a an?lise comparativa dos m?todos dos fatores ponderados na sele??o de ?reas para implanta??o de aterros sanit?rio, aplicando as metodologias de crit?rios classificat?rios, com faixas de pontua??o, no aterro sanit?rio de Massaranduba, localizado no munic?pio de Cear? Mirim/RN. O Estudo foi realizado a partir da necessidade de termos uma metodologia ou seguir alguma metodologia de baixa complexidade tecnol?gica e baixo custo operacional para a sele??o de ?reas prop?cias para a implanta??o de aterros sanit?rios nos diversos munic?pios do Estado do Rio Grande do Norte. A partir da exig?ncia legal, com a aprova??o da Lei 12.305/2010, que instituiu a Pol?tica Nacional de Res?duos S?lidos, e que prev? a extin??o dos lix?es, considerando-se tamb?m as caracter?sticas locais, ambientais e s?cio-econ?micas encontradas que possibilitem essa instala??o. O Estado do Rio Grande do Norte, atrav?s da Secretaria Estadual do Meio Ambiente e dos Recursos H?dricos (SEMARH) e o Instituto de Desenvolvimento Sustent?vel e Meio Ambiente do RN (IDEMA), autoridades federais, estaduais e municipais, na defini??o de pol?ticas p?blicas voltadas para a gest?o integral dos res?duos s?lidos urbanos que contemplem a preserva??o ambiental e as melhorias das condi??es sanit?rias da popula??o potiguar, dever?o estruturar e planejar a??es com medidas mitigadoras para que os 97% dos munic?pios do Estado atendam as exig?ncias legais e consigam extinguir a situa??o atual da destina??o inadequada dos seus res?duos s?lidos urbanos em lix?es a c?u aberto conforme dados de 2009. O estudo conclui que, a ?rea do aterro sanit?rio de Massaranduba foi classificada como ?tima pelo m?todo do IQR, aceit?vel pelo Sistema de Pontua??o e por Gomes; Coelho; Erba & Verovez e por Waquil et al. O estudo tamb?m conclui que, dentre os m?todos analisados, para este estudo de caso, o da Uni?o dos Munic?pios da Bahia(Sistema de Pontua??o) apresenta-se como o mais rigoroso para a sele??o de ?reas e o IQR como o mais flex?vel
186

Compactação e compressibilidade de resíduos sólidos urbanos / Compaction and compressibility of municipal solid waste

Afonso Celso Moruzzi Marques 17 July 2001 (has links)
Os objetivos desta pesquisa incluem: (i) estudar as características de compactação dos resíduos sólidos urbanos (RSU); (ii) avaliar os mecanismos de compressão dos RSU e o efeito de sobrecarga (aterro experimental) em maciço sanitário existente; (iii) desenvolver programa computacional para previsão de recalques em aterros sanitários. Um aterro experimental com cerca de 24.400 \'M POT.3\' de RSU e altura de até 4 m, distribuído em área aproximada de 8.400 \'M POT.2\', foi construído em São Paulo para estudar os procedimentos de compactação de aterros sanitários. Ensaios in situ de grande dimensão foram executados para avaliar o peso específico do resíduo, após a compactação, em diferentes posições e camadas do experimento. Ensaios de umidade e composição dos resíduos foram realizados, assim como o levantamento das espessuras das camadas para cada etapa construtiva. O aterro experimental foi construído sobre aterro existente, criando a oportunidade para estudar a compressão do resíduo novo e antigo. Rigoroso programa de monitoração de recalques foi implantado, de forma que as deformações do aterro experimental pudessem ser isoladas das do aterro existente. Marcos superficiais foram posicionados interna e externamente à área do experimento, e placas de recalque instaladas na base do aterro experimental. O período de monitoramento envolveu cerca de 3 anos de medidas. A pesquisa resultou em: (i) novos subsídios e relações para a compactação dos RSU, incluindo as influências do equipamento de compactação, número de passadas, espessura das camadas, plano de compactação e teor de umidade, mostrando ser este último o parâmetro de maior impacto no processo de compactação; (ii) dados de peso específico e de sua relação com a profundidade, assim como do efeito da compactação na compressibilidade dos RSU e na geração de líquidos percolados em aterros sanitários; (iii) avaliação do desempenho de modelos de compressibilidade existentes na literatura; (iv) desenvolvimento de modelo compósito para compressibilidade dos RSU, considerando a compressão mecânica primária e secundária e a parcela devido a biodegradação dos resíduos; (v) desenvolvimento do programa MSWSET usando o modelo compósito para cálculo dos recalques de aterros como função do tempo. O modelo e programa desenvolvidos apresentaram elevado desempenho, constituindo importante ferramenta para previsão de recalques de aterros sanitários. / The objectives of this research were to: (i) study the compaction characteristics of municipal solid waste (MSW); (ii) evaluate the compression mechanisms of MSW and its response to a surcharge (waste test fill) over an existing landfill; (iii) develop a computer program for landfill settlement predictions. A waste test fill with a volume of about 24,400 \'M POT.3\' and a height up to 4 m, distributed over an area of approximately 8,400 \'M POT.2\', was constructed in Sao Paulo, to study compaction procedures for sanitary landfills. Large in situ tests were performed to evaluate the unit weight of waste immediately after compaction at several locations for each lift. Water content measurements and composition determinations were carried out, as well as thickness measurements of the waste layers after each construction (compaction) phase. The test fill was constructed over an existing landfill. Thus, the test fill provided opportunities to study the compression of the new and the old waste. A rigorous program of deformation monitoring was implemented in order to separate compression of the test fill from settlement of the underlying landfill. Benchmarks were located inside and outside of the experimental area, and settlement plates were installed at the bottom of the test fill. The monitoring period encompasses around 3 years of measurements. The research provided: (i) new guidelines and relationships for compaction of municipal solid waste, including the influences of compaction equipment, number of passes, lift thickness, water content, and compaction plane. The water content has presented larger response on the compaction process than the other variables; (ii) quantitative data regarding unit weight, the influence of depth on unit weight, water content, compressibility of MSW, and leachate generation; (iii) assessment of the performance of existing MSW compressibility models described in the literature; (iv) development of a composite model of MSW compressibility that considers primary compression, secondary mechanical compression, and compression from biodegradation; (v) development of the computer program MSWSET using the composite model of MSW compressibility to calculate landfill settlement as a function of time. The developed model and program has presented a high performance, being a powerful tool for landfill settlement prediction.
187

Recuperação ambiental de aterros sanitarios na região metropolitana de Campinas : revegetação e uso futuro

Oliveira, Cauê Nascimento de, 1976- 28 January 2005 (has links)
Orientador: Elvira Gabriela Ciacco da Silva Dias / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-04T11:03:08Z (GMT). No. of bitstreams: 1 Oliveira_CaueNascimentode_M.pdf: 3646130 bytes, checksum: 732105bee70d3293ec3b7068547652e0 (MD5) Previous issue date: 2005 / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
188

Closure of the Umlazi landfill : meeting statutory requirements for engineering and plant cover.

Mannie, Neeraj Mannie. January 2008 (has links)
This study investigated the establishment of vegetation cover planted in plug and seedling form in the closure phases of the Umlazi Landfill. It also investigated the various facets of the closure process of the Umlazi Landfill and the effect these have on the establishment and choice of vegetative cover, and the grass technology used to make the establishment of vegetation a success. The setting up of trials and the gathering of basic data were undertaken to assess the alternative vegetation options available to researchers. The cover provided by the grasses was assessed in the investigation. The capping of landfill sites is a relatively new approach and it is soon to become a mandatory requirement by the Department of Water Affairs and Forestry (Minimum Requirements for Waste Disposal) (DWAF, 1998). This systematic investigation used in the closure of the Umlazi Landfill, will provide a model for the capping of landfills in South Africa. Seeing that this was the first hazardous (H:h) landfill site in the country to be closed according to the Minimum Requirements for Waste Disposal (DWAF, 1998), every attempt was made to ensure that all aspects in the closure of the site met with the Minimum Requirements. The Minimum Requirements document mentions only briefly that the landfill must be vegetated with some grass type. Prior to 1994, capped landfill sites were usually planted with traditional grass seed mixes and these were not widely successful, as seen on many older landfills that have been partially or completely capped, and where vegetation cover is sparse. There is much literature in the developed countries on the closure of landfills (e.g., Erickson, During the site inspections in June 2001 and February 2002, it was noted that many species of alien plants had established themselves in the poor soil conditions. This made it even more important to find indigenous vegetation to vigorously establish itself that would prevent the establishment of alien invaders. Samples of grass species established on some part of the site were also taken for identification. The dominant grass was identified as Cynodon dactylon. In view of establishing a balanced vegetative cover on top of the Umlazi Landfill, Acacia karoo trees (in seedling form) were also planted. Three bunch grass species, Melinis nerviglumis, Melinis minutiflora and Hyparrhenia hirta, were tested to see if thatching grass could be grown on the site to generate a cash crop for local residents of Umlazi township. Preparation and planting of the capped areas took place in the latter part of 2003 and were completed in early 2004. Measurements and field data were recorded and statistically analysed. The trials revealed three key findings: Firstly, both creeping grasses studied, namely Cynodon dactylon var. “Sea Green” and Panicum natalense var. ”Natal Buffalo Grass” grew well on the site. Initially P. natalense grew faster but after a month, C. dactylon overtook it. At the end of the trial (six months, P. natalense provided a higher level of soil cover. However, C. dactylon grew more consistently over this period. Hence both species provided good growth and cover on this site. Secondly the three bunch grasses, Melinis nerviglumis, Melinis minutiflora and Hyparrhenia hirta, all grew well and had similar survival rates. Hence the potential for growing these grasses as a cash crop has potential. Thirdly, all the Acacia karoo trees survived, i.e., they achieved 100% survival. The average height increase and stem width was similar in all trials and growth was consistent over the six month growing period. Hence the tree species would be a good choice for planting on landfills in its ecologically suitable zones. It is therefore feasible to envisage the planting of a mixture of grasses under the cover of A. karoo trees, to provide a balanced mixture of indigenous grasses to cover a freshly capped landfill. Such a system should provide for stable growth of vegetation for many years. / Thesis (M.Sc.)-University of KwaZulu-Natal, Pietermaritzburg, 2008
189

Análise de componentes tóxicos em resíduos sólidos urbanos.

SILVA, Alessandra dos Santos. 25 June 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-06-25T21:34:15Z No. of bitstreams: 1 ALESSANDRA DOS SANTOS SILVA – TESE (UAEMa) 2016.pdf: 3974820 bytes, checksum: 227b7bdb0c87a7363c463b6c11f06469 (MD5) / Made available in DSpace on 2018-06-25T21:34:15Z (GMT). No. of bitstreams: 1 ALESSANDRA DOS SANTOS SILVA – TESE (UAEMa) 2016.pdf: 3974820 bytes, checksum: 227b7bdb0c87a7363c463b6c11f06469 (MD5) Previous issue date: 2016-02-15 / Capes / Os resíduos sólidos considerados perigosos, embora possam estar presentes em menor quantidade na composição dos Resíduos Sólidos Urbanos (RSU), contribuem para toxicidade do meio em que estão inseridos . Dentre as frações de resíduos perigosos, presentes nos RSU, os metais são os que apresentam maior preocupação por possuírem características intrínsecas que podem causar diversos danos à saúde pública e ao meio ambiente. Ademais, os subprodutos gerados pela própria decomposição dos resíduos também podem causar efeito deletério ao meio, a exemplo dos compostos nitrogenados, especialmente a amônia, que em elevados teores, torna-se tóxica, dificultando os processos de degradação. Diante disso, a busca por alternativas tecnológicas para manejo adequado dos RSU e entendimento do seu comportamento após destinação final, tem feito com que cada vez mais estudos sejam desenvolvidos para esse fim. Assim, com este trabalho objetivou-se analisar o efeito dos componentes tóxicos presentes nos resíduos sólidos urbanos, da cidade de Campina Grande – PB, após sua disposição final em uma célula experimental. O experimento consistiu na construção, instrumentação, desenvolvimento de planejamento estatístico e preenchimento de uma célula experimental que simula uma célula de aterro sanitário em escala real. Após preenchimento, foi realizada a caracterização física dos resíduos sólidos e mensalmente amostras foram coletadas para monitorar o comportamento dos parâmetros físico-químicos, microbiológicos e mineralógicos, bem como a influência da toxicidade nos RSU, ao longo do tempo e da profundidade. Os resultados obtidos mostraram que os resíduos da cidade de Campina Grande – PB, de acordo com NBR 10.004/2004, podem ser classificados como resíduos perigosos (Classe I). Contudo, essa periculosidade não afeta o processo biodegradativo, uma vez que os micro-organismos possuem capacidade de adaptarem-se as condições adversas e, portanto, de resistirem aos efeitos que os compostos tóxicos podem causar. Em suma, os RSU da cidade de Campina Grande – PB apresentam potencial tóxico ao meio ambiente e a saúde pública, no entanto não são tóxicos para a atividade degradativa que ocorre no interior da massa de resíduos sólidos. / Solid waste deemed hazardous, although they may be present in small amounts in the composition of Municipal Solid Waste (MSW), feature importance, since they contribute to toxicity of the environment in which they live. Among the hazardous waste fractions present in MSW, the metals are at greatest concern because they have intrinsic characteristics that can cause extensive damage to public health and the environment. In addition, the byproducts generated by the decomposition of the waste can also cause deleterious effects to the environment, like the nitrogen compounds, especially ammonia, which at high levels, it is toxic, hindering the degradation processes. Therefore, the search for alternative technologies for proper management of MSW and understanding of their behavior after disposal has meant that more and more studies are developed for this purpose. Thus, this work aimed to analyze the effect of the toxic components present in municipal solid waste in the city of Campina Grande - PB, after its disposal in an experimental cell. The experiment consisted of the construction, instrumentation, development of statistical planning and completing an experimental cell simulating a landfill cell at full scale. After filling, the physical characterization of waste was carried out and samples were collected every month to monitor the behavior of physicalchemical, microbiological and mineralogical parameters as well as the influence of toxicity in MSW, along the time and depth. The results showed that the waste from the city of Campina Grande - PB, according to NBR 10.004 / 2004 can be classified as hazardous waste (Class I). However, this affects the hazardous biodegradation process, since the microorganisms have the ability to adapt to adverse conditions and therefore resist the effects that can cause toxic compounds. In short, the MSW in the city of Campina Grande - PB have potentially toxic to the environment and public health, but they are not toxic to the degradative activity that occurs within the mass of solid waste.
190

Avaliação e melhoria do poder calorífico de biogás proveniente de resíduos sólidos urbanos

Okamura, Layssa Aline 27 March 2013 (has links)
CNPq, CAPES / Com o novo cenário mundial voltado às práticas sustentáveis está se tornando um foco importante de pesquisa a busca por tecnologias que utilizem recursos renováveis e que diminuam ou eliminem a produção de contaminantes e poluentes ambientais em processos de obtenção de energia. A partir disto, esta dissertação focou a purificação de biogás produzido em aterro sanitário desativado na cidade de Curitiba (Caximba) para avaliar a sua utilização na produção de energia, melhorando o seu poder calorífico. Durante o estudo foi desenvolvido um calorímetro para determinar o poder calórico do biogás. Para comparação dos resultados foram feitas análises das concentrações de metano, dióxido de carbono, amônia e gás sulfídrico através de um kit comercial para análise de biogás. As coletas e análises do biogás foram realizadas em dois locais no aterro com diferentes idades de resíduo confinado. Foram identificadas diferenças significativas nos teores de metano e gás sulfídrico nos gases estudados. A purificação do biogás foi realizada através da aplicação de colunas recheadas com solução de acetato de chumbo, solução de hidróxido de sódio, sílica gel e carvão ativo. A purificação atingiu até 73% de teor de metano. A eficiência de purificação foi maior ainda para o tratamento do biogás com menor teor de metano (23%), aonde a eficiência chegou a 145% em relação ao valor inicial. A utilização de indicadores de saturação mostrou-se bastante interessante no uso das colunas de purificação, pois a saturação podia ser determinada visualmente. Uma vez calculadas os percentuais de purificação do biogás foram estimadas a produção de energia, a venda da mesma com geração de receita e os custos relacionados ao processo de purificação. Através destas estimativas verificou-se que a renda da venda de energia elétrica produzida seria suficiente para arcar com os custos da aplicação do processo de purificação. / Given the new global scenario turned to sustainable practices it is becoming a major focus of research the search for technologies that use renewable resources reducing or eliminating the production of environmental pollutants and contaminants in energy production process. This project focused on the purification of biogas in Curitiba’s closed landfill of to evaluate its use for energy production, aiming to improve its calorific value. During the study, a calorimeter was developed and optimized to evaluate the calorific value of the biogas. For results comparison, analyses were made to determinate the concentrations of methane, carbon dioxide, ammonia and hydrogen sulfide using a commercial kit for analysis of biogas. Landfill biogas sampling and analysis were conducted at two sites where the waste was confined at different times. We identified significant differences in the levels of methane and hydrogen sulfide in the analyzed gases. Biogas purification was performed by applying columns packed with lead acetate solution, sodium hydroxide solution, silica gel and activated carbon. A higher efficiency of biogas purification (145%) was attained with a lower initial methane content (23%). The use of saturation indicators proved to be very interesting in the use of purification column, since the saturation could be determined visually. With the purification percentage calculated, it was estimated the energy production, revenue through energy sale and costs related to the purification process. Through this estimation it is possible to note that the profits from the electricity produced sale would be sufficient to meet the costs of the purification process application.

Page generated in 0.038 seconds