• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 17
  • 17
  • 17
  • 11
  • 10
  • 9
  • 9
  • 8
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Analise fotoelastica das tensoes induzidas por estruturas de protese sobre implantes fabricadas pelas tecnicas monobloco, soldagem de borda e metodo CAD/CAM / Photoelastic analysis of tensions induced over implant superstructures manufactured through CAD/CAM method, border soldering and one-piece technique

Cariello, Mauricio Pompeu 19 April 2007 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T18:09:17Z (GMT). No. of bitstreams: 1 Cariello_MauricioPompeu_M.pdf: 1539853 bytes, checksum: 66ce285cbbabfeefc457ae942dd8e5a1 (MD5) Previous issue date: 2005 / Resumo: A falta de passividade de infra-estruturas protéticas implantossuportadas pode acarretar problemas mecânicos e biológicos de grande importância. A proposta deste trabalho foi avaliar, pela técnica da fotoelasticidade, a tensão após o torque de estruturas metálicas protéticas implantossuportadas. Simulando a curvatura de uma mandíbula humana, foi confeccionada uma matriz em aço inoxidável e instalados 5 análogos de pilares do tipo Micro-Unit (Conexão Sistemas de Próteses - São Paulo - Brasil), dispostos simetricamente. Pela técnica convencional da cera perdida e fundição em titânio c.p., foram fabricadas duas infra-estruturas em monobloco, uma pela técnica convencional e outra adaptada sobre cilindros de titânio. Pelo método CAD/CAM (Computer-Aided Design/Computer-Assisted Manufacturing) foi confeccionada uma infra-estrutura fresada por computador (CAM StructSURE® - 3i Implant Innovations), onde pilares da matriz metálica foram digitalizados a laser e, posteriormente, um bloco de titânio foi usinado originando uma infra-estrutura em monobloco. A matriz metálica foi moldada com silicone de duplicação (Silicone Master ? Talladium do Brasil) pela técnica de moldagem com transferentes quadrados unidos com resina acrílica (GC Pattern - GC Dental). A partir deste molde, foi obtida a matriz em resina fotoelástica (Araldite ? Araltec) com 5 implantes unidos a pilares Micro-Unit incorporados (Master Screw ? Conexão - SP). O estudo foi dividido em três grupos e foi confeccionada uma estrutura metálica para cada grupo com forma e tamanho padronizados de acordo com o protocolo clínico e laboratorial preconizados por Branemark e cols. No grupo I, foi confeccionada uma infraestrutura em titânio fundida em monobloco. No grupo II, realizou-se a técnica da soldagem a laser (Desktop Dentaurum ? Alemanha) na união da borda dos cilindros de titânio à infra-estrutura (Conexão), permitindo maior adaptação. No grupo III foi confeccionada uma infra-estrutura em monobloco pelo método CAD/CAM, onde a matriz de aço inoxidável foi escaneada a laser e a peça foi fresada a partir de um bloco de titânio maciço (3i Implant Innovations). O assentamento passivo foi avaliado pela análise fotoelástica, onde todos os parafusos receberam torque de 10Ncm e as franjas isocromáticas foram analisadas por um polariscópio circular acoplado a uma máquina fotográfica digital (Cyber-Shot DSC-717 - Sony) que registrou as imagens. Os resultados evidenciaram maior concentração de tensão no implante central 3 em todos os grupos, sendo que nos grupos II e III a tensão foi consideravelmente menor que no grupo I. A infra-estrutura fundida em monobloco apresentou elevado grau de tensão distribuída em praticamente todos os implantes, sendo necessário aperfeiçoamento do método. A técnica de soldagem de borda de cilindros de titânio demonstrou ser viável com resultados superiores à tecnologia CAD/CAM / Abstract: The lack of passivity of the implant supported prosthesis may lead to mechanical and biological disorders. The purpose of this research was to evaluate, using photoelasticity analysis, the stress over the implants after tightening the prosthesis superstructure. Simulating the mandible anatomy, a stainless steel matrix was used with 5 Micro-Unit abutments (Conexão Sistemas de Próteses ? São Paulo ? Brazil), positioned symmetrically. Using the lost wax and titanium casting technique were fabricated two superstructures, one in one-piece and the other one adapted and soldered over five titanium cylinders. By the CAD/CAM technique (Computer-Aided Design/Computer-Assisted Manufacturing) one superstructure was fabricated, using laser to digitalize the abutments of the matrix and after this procedure the bar was designed and an titanium block was cut originating one-piece bar (CAM StructSURE® - 3i Implant Innovations). The matrix was forged with duplication silicone (Silicone Master ? Talladium do Brazil) connecting the transfers abutments with acrylic resin (GC Pattern - GC Dental). From the cast was fabricated the photoelastic model (Araldite ? Araltec) with five regular implants in it (Master Screw ? Conexão - SP). The research had three groups and the superstructure had the shape used by Branemark et al.. The group I, II and III were formed by the one-piece bar, one-piece bar soldered over titanium cylinders and one-piece bar made by the CAD/CAM technique (3i Implant Innovations), respectively. The passive fit was evaluated using photoelastic analysis and all screws had a 10Ncm torque and the fringes were analyzed by a round polariscope with a digital photo machine coupled on it (Cyber-Shot DSC-717 - Sony), which registered the images. The results demonstrated the tension concentration over the middle implant (3) in all groups, but the groups I and II showed less tension concentration than the group I. The border soldering technique was viable with better results compared to the CAD/CAM technique / Mestrado / Protese Dental / Mestre em Clínica Odontológica
12

Analise fotoelastica e extensometrica das tensoes induzidas por estruturas de protese sobre implantes fabricadas pelas tecnicas monobloco, soldagem de borda e metodo CAD/CAM / Photoelastic and strain gauge analysis of tensions induced over implant superstructures manufactured through one-pierce technique., bolder soldering and CAD/CAM method, border soldering and one-piece technique

Cariello, Mauricio Pompeu 14 August 2018 (has links)
Orientador: Mauro Antonio de Arruda Nobilo. / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T23:46:41Z (GMT). No. of bitstreams: 1 Cariello_MauricioPompeu.pdf: 14825222 bytes, checksum: dd8b86773e817cddafc6cf356350abd7 (MD5) Previous issue date: 2009 / Resumo: A ausência de passividade de infra-estruturas protéticas implantossuportadas pode gerar problemas mecânicos e biológicos de grande importância sobre os implantes. Utilizando as técnicas de análise fotoelástica e extensométrica, o objetivo neste trabalho foi avaliar a tensão após a instalação de infra-estruturas metálicas protéticas implantossuportadas sobre cinco implantes. Foi confeccionada uma matriz em aço inoxidável e instalados 5 análogos de pilares do tipo Micro-Unit (Conexão Sistemas de Próteses - São Paulo - Brasil), dispostos simetricamente de acordo com o protocolo preconizado por Branemark. O estudo foi separado em três grupos. O grupo I foi representado por uma infraestrutura de titânio fundida em monobloco. No grupo II, a infra-estrutura em monobloco foi adaptada sobre cilindros de titânio pela técnica da soldagem de borda a laser (Desktop Dentaurum - Alemanha). No grupo III, foi confeccionada por computador uma infra-estrutura em monobloco de titânio pelo método CAD/CAM (3i Implant Innovations - EUA). Para a obtenção da matriz em resina fotoelástica (Araldite - Araltec) foi realizada a moldagem de transferência (Silicone Master - Talladium do Brasil) dos pilares Micro-Unit da matriz de aço inoxidável. O assentamento passivo foi avaliado pelas análises fotoelástica, quando todos os parafusos receberam torque de 10Ncm sendo as tensões analisadas por polariscópio circular e registradas por máquina fotográfica digital (Cyber-Shot DSC-717 - Sony). Posteriormente, foram instalados extensômetros de superfície na região entre os implantes para verificar as tensões geradas entre os mesmos após a instalação de cada infra-estrutura. Os resultados evidenciaram que a infraestrutura fundida em monobloco apresentou maior grau de tensão sobre os implantes enquanto as técnicas de soldagem de borda de cilindros de titânio e CAD/CAM demonstraram ser viáveis, com resultados satisfatórios. / Abstract: The lack of passivity of the implant supported prosthesis may lead to mechanical and biological disorders over the implants. By the photoelastic and strain gauge analysis, the purpose of this research was to evaluate the stress over the implants after tightening the prosthesis superstructure over five dental implants. A stainless steel matrix was manufactured and used with 5 Micro-Unit abutments (Conexao Sistemas de Proteses - Sao Paulo - Brazil), positioned symmetrically according to the Branemark protocol. This research has three groups: group I has one-piece bar. The group II has one-piece bar adapted and soldered over titanium cylinders. The group III has one-piece bar made by the CAD/CAM technique (3i Implant Innovations - EUA). The matrix was forged with duplication silicone (Silicone Master - Talladium do Brazil) connecting the transfers abutments with acrylic resin (GC Pattern - GC Dental). From the cast was fabricated the photoelastic model (Araldite - Araltec) with five regular implants in it (Master Screw - Conexao - SP). The passive fit was evaluated using photoelastic and strain gauge analysis and all screw had a 10Ncm torque. The fringes were analyzed by a round polariscope with a digital photo machine coupled on it (Cyber-Shot DSC-717 - Sony), which registered the images and the tension was recorded by the strain gauges coupled on a computer. The results demonstrated that the tension concentration over the group I was high in all dental implants, being necessary to improve the manufacturing technique. The border soldering technique proved to be viable with satisfactory result as the CAD/CAM technique. / Tese (Douttorado) - Universida / Protese Dental / Doutor em Clínica Odontológica
13

Análise comparativa da alteração dimensional entre dois métodos de soldagem: arco elétrico com proteção de argônio (TIG) e maçarico para uma liga metalocerâmica à base de Ni-Cr.

Adilson Hideki Ueno 29 November 2000 (has links)
O presente trabalho buscou avaliar a alteração dimensional provocada pelo processo de soldagem a arco elétrico com proteção de argônio (TIG) e comparar os resultados com os obtidos a partir da técnica convencional a maçarico para uma liga à base de Ni-Cr, Verabond2. Para isso, foi utilizado um dispositivo metálico que simulava uma condição clínica de dois elementos pilares de uma prótese fixa com um espaço protético. Sobre esse dispositivo foram confeccionados os corpos de provas, fundidos com a referida liga. Os corpos de provas consistiam de casquetes metálicos adaptados ao pilares do dispositivo, tendo sobre as suas faces oclusais as duas metades de uma barra cilíndrica de 4,0 mm de diâmetro. Para que a comparação entre as duas técnicas fosse possível, foram idealizados dois grupos experimentais: Grupo I: junta em corte vertical com faces paralelas e soldagem convencional a maçarico Grupo II: junta em corte vertical com faces paralelas e soldagem a arco elétrico com proteção de argônio – processo TIG Dez juntas foram soldadas de acordo com o método correspondente para cada processo e a mensuração das distorções causadas pelas duas técnicas de soldagem foi feita pela diferença entre o assentamento das peças antes e após a obtenção das juntas soldadas. Observadas as medidas e calculadas as diferenças para os dois grupos, procedeu-se a análise estatística, o que permitiu concluir que: 1. Entre as duas técnicas de soldagem avaliadas, a solda TIG apresentou uma maior contração da junta e conseqüentemente uma maior alteração dimensional quando comparada ao método convencional a maçarico; 2. A solda TIG permite um melhor assentamento da peça soldada quando comparados os seus resultados com os da soldagem convencional a maçarico, desde que a quantidade de líquido especial utilizado na manipulação do revestimento para a soldagem seja de100%; 3. A solda TIG, desde que utilizada da maneira descrita, pode produzir juntas soldadas com uma precisão satisfatória. / The present study was performed to evaluate the dimensional alteration caused by the soldering process using argon protected electric arch (TIG process) and compare the results with those obtained with the conventional soldering technique, using a nickel-chromium alloy (Veradond 2) for the samples. A metallic device was used to simulate a clinical condition: two abutments of a fixed partial denture with an intermediary edentulous space. The specimens to be tested were prepared over the apparatus, using the referred alloy, and consisted of metallic copings adapted to the abutments. They had two halves of a cylindrical bar with 4,0mm of diameter on both occlusal faces. To make the comparison possible, two situations of groups were idealized: Group I: vertical section of the joint with parallel faces and convenctional soldering process (blow-torch); Group II: vertical section of the joint with parallel faces and Tungsten inert gas soldering process. Ten joints were soldered according the correspondent method for each process and the measuring of the distortions caused by two techniques was perfomed using the difference between sitting of copings before and after the soldering process. After observation, the differences between the two groups were calculated and statistically analyzed. The conclusions were: 1) The TIG process showed more joint contraction and consequently more dimensional alteration when compared to the conventional method (Blow-torch); 2) The TIG process allows a better sitting of the piece when compared to the conventional blow-torch soldering, since the 100% amount of investment liquid be used for that type of soldering; 3) The TIG process can produce soldered joints with satisfactory resistance and precision, when used by the proper manner.
14

Avaliação da distorção linear em estruturas métalicas de próteses sobre implantes : fundidas em peça única e em segmentos soldados a laser e através da soldagem convencional (brasagem) /

Costa, Elza Maria Valadares da. January 2001 (has links)
Orientador: Maximiliano Piero Neisser / Banca: Mauro Antonio de Arruda Nóbilo / Banca: Marco Antonio Bottino / Resumo : Próteses sobre implantes osseointegrados requerem critério de fabricação preciso devido a ausência de tecidos periodontais que compensam erros menores de relacionamento. Para tanto, em um arco mandibular edêntulo, construído em aço-cromo, foram fixados cinco análogos de pilares de implante, paralelos entre si, com distância de 10mm medidos de centro a centro. Sobre estes foram parafusados novos cilindros de ouro, com torque de 10 N/cm. Então foram executadas 15 sobre-estruturas metálicas que foram divididas: GC - Adaptação passiva dos cilindros de ouro; GM - monobloco GB - segmentos soldados por brasagem e, GL - segmentos soldados a laser. Observou-se as estruturas parafusadas com parafusos sempre novos sob microscópio de mensuração. A medição foi realizada na vestibular e lingual da interface cilindro/análogo e dados anotados em tabela apropriada. Para o eixo y, a técnica de soldagem a laser (Media=12,41 e Dp=11,12) produziu menos distorção significativamente do que a técnica de brasagem (Media=23,06 e Dp=13,31) seguida pela técnica de monobloco (Media=39,83 e Dp=21,88) p= 0.05. Para o eixo x, somente o grupo Monobloco apresentou diferença significativa para as demais técnicas (Média= 45,66 e Dp=21,56) / Abstract: Prosthesis above osseointegrated implants requires an accurate criterion of manufacture. So, in an edentulous mandibular arch, constructed with "chromium steel", five analogous were fixed, parallels, with distance of 10 mm measured of center to center. Above these gold cylinders were positioned and screwed with a torque of 10 N/m. In the next follow, fifteen over structures were fabricated and divided in tour groups: CG - Passive adaptation of gold cylinders; MG - Monobloc casting; BG - Casting in segments after brasing; LG - Casting in segments after laser welding. The structures were observed with measures microscope and the data noted in specific table. The measures done in two points (left and right) in the buccal and lingual surfaces of the interface of the cylinder/analogous set in the x and y-axis. The statistics analysis (ANOVA) showed significant statistics differences, on y-axis, among groups: LG group was superior to BG and this was superior to MG group and on x-axis only MG was superior to others groups (when we studied distortion.) / Mestre
15

Avalia??o in vitro e in vivo da citotoxidade e da genotoxicidadde das soldagens a prata, a Tungsten Inert Gas (TIG) e a laser em ortodontia

Rinaldi, Mariana Roennau Lemos 19 January 2017 (has links)
Submitted by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-06-30T14:39:33Z No. of bitstreams: 1 TES_MARIANA_ROENNAU_LEMOS_RINALDI_COMPLETO.pdf: 2232512 bytes, checksum: 72ea5572f7e50b32cdf95dc1dbfe7366 (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-06-30T14:39:42Z (GMT) No. of bitstreams: 1 TES_MARIANA_ROENNAU_LEMOS_RINALDI_COMPLETO.pdf: 2232512 bytes, checksum: 72ea5572f7e50b32cdf95dc1dbfe7366 (MD5) / Made available in DSpace on 2017-06-30T14:39:51Z (GMT). No. of bitstreams: 1 TES_MARIANA_ROENNAU_LEMOS_RINALDI_COMPLETO.pdf: 2232512 bytes, checksum: 72ea5572f7e50b32cdf95dc1dbfe7366 (MD5) Previous issue date: 2017-01-19 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / Soldered appliances are widely used in orthodontics and pediatric dentistry. The cytotoxicity and genotoxicity of silver solder and laser welding has already been tested in dentistry. However, little is known about the Tungsten Inert Gas (TIG) welding technique, which uses an electric arc between an electrode and the part to be welded. The aims of this study were to evaluate the cytotoxicity and genotoxicity of silver soldered (silver soldered bands - SSB), laser welded (laser welded bands - LWB), TIG welded (TIG welded bands ? TWB) joints and no soldered/welded bands (NS /WB) in vitro and in vivo. For that, MTT reduction assay was performed in HGF, HaCat, Vero and MRC-5 cell lines. The genotoxicity of the metallic eluates of the joints was determined by comet assay in HGF cells after 3-h treatment. The quantification of Ni, Fe, Cr, Cu, Ag, Zn Cd and Sn in the metallic eluates was performed with inductively coupled plasma mass spectrometry (ICP-MS). Cu, Zn and Ag were the most detected ions in SSB medium samples, and Fe, Cr and Ni in the samples of LWB and TWB. The SSB group induced strong cytotoxicity in all cell lines. NS/WB, LWB and TWB presented a weak cytotoxic induction. In comet assay, SSB group showed a higher damage index and more comets with damage class 3 and 4, compared to the other groups. In the in vivo study, the genotoxic effects on the buccal mucosa cells of children with lingual arches containing silver soldered joints, laser welded joints and without any appliance were accessed by buccal comet assay (BCA) and the buccal micronucleus cytome (BMCyt) assay. The urinary levels of Ni, Cr, Fe, Zn, Cu, Ag, Cd and Sn were investigated through urine samples analyzed by ICP-MS. The results of the study indicate that silver solder and laser welding did not cause genotoxicity in buccal mucosa cell during the period evaluated. The changes of the ions in the urinary contents cannot only be attributed to the appliances. TIG welding may be a promising technique to be applied in orthodontics and deserve be further investigated, as it presented in the in vitro and in vivo tests a low cytotoxic and genotoxic potential. / Aparelhos soldados s?o utilizados amplamente em Ortodontia e Odontopediatria. A citotoxicidade e a genotoxicidade da solda a prata e da soldagem a laser j? foram testadas em Odontologia. No entanto, pouco se sabe sobre a t?cnica de soldagem Tungsten Inert Gas (TIG), que utiliza um arco el?trico entre um eletrodo e a pe?a a ser soldada. Os objetivos deste estudo foram avaliar a citotoxicidade e a genotoxicidade de uni?es soldadas a prata (silver soldered band - SSB), soldadas a laser (laser welded band - LWB), soldadas a TIG (TIG welded band ? TWB) e de an?is n?o soldados (no soldered or welded bands ? NS / WB) in vitro e in vivo. Para isso, o ensaio de redu??o de MTT foi realizado nas linhagens celulares HGF, HaCat, Vero e MRC-5. A genotoxicidade dos eluatos met?licos das ?reas soldadas foi determinada atrav?s do ensaio de cometas em c?lulas HGF ap?s tratamento de 3 horas. A quantifica??o de Ni, Fe, Cr, Cu, Ag, Zn, Cd e Sn nos elu?dos met?licos foi realizada com espectrometria de massa por plasma indutivamente acoplado (ICP-MS). Cu, Zn e Ag foram os ?ons mais detectados nas amostras de meio de bandas soldadas a prata, e Fe, Cr e Ni, nas amostras soldadas a laser e nas soldadas a TIG. O grupo SSB induziu forte citotoxicidade em todas as linhagens celulares. NS / WB, LWB e TWB apresentaram indu??o citot?xica fraca. No ensaio Cometa, o grupo SSB apresentou maior ?ndice de danos e mais cometas com classes de dano 3 e 4, em rela??o aos outros grupos. As uni?es soldadas a TIG, bem como uni?es soldadas a laser mostraram melhor biocompatibilidade. No estudo in vivo, genotoxicidade sobre as c?lulas da mucosa bucal dessas crian?as com arcos linguais contendo uni?es soldadas a prata, uni?es soldadas a laser, e sem qualquer aparelho foram avaliadas pelo ensaio de cometa bucal (BCA) e pelo ensaio de citometria bucal do micron?cleo (BMCyt). Os n?veis urin?rios de Ni, Cr, Fe, Zn, Cu, Ag, Cd e Sn foram investigados atrav?s de amostras de urina analisadas por ICP-MS. Os resultados do estudo indicam que a solda a prata e a soldagem a laser n?o causaram genotoxicidade na mucosa bucal durante o per?odo avaliado. As altera??es dos ?ons no conte?do urin?rio n?o puderam ser unicamente atribu?das aos aparelhos. A soldagem TIG parece ser t?cnica promissora a ser aplicada em ortodontia e merece ser mais investigada, uma vez que apresentou nos testes in vitro e in vivo um baixo potencial citot?xico e genot?xico.
16

Análise da desadaptação marginal vertical e horizontal de infraestruturas de próteses fixas implantossuportadas confeccionadas através de diferentes técnicas /

Gomes, Jéssica Marcela de Luna. January 2018 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientadora: Sandra Lúcia Dantas de Moraes / Banca: Fellippo Ramos Verri / Banca: Mônica Maria Albuquerque Pontes / Resumo: O objetivo deste trabalho foi avaliar a desadaptação marginal vertical, horizontal e interna de infraestruturas e próteses fixas implantossuportadas confeccionadas através de diferentes técnicas. Além disso, realizar uma revisão sistemática e meta-análise avaliando o efeito da soldagem de infraestruturas de próteses fixas implantossuportadas em uma melhor adaptação quando comparada as infraestruturas confeccionadas em monobloco. Um total de 30 infraestruturas foram confeccionadas e divididas em 3 grupos: G1) Técnica convencional da cera perdida (n=10); G2) CAD/CAM (n=10); G3: CAD/CAM + Técnica da cera perdida (n=10). Uma matriz foi utilizada para simular uma prótese fixa implantossuportada de três elementos com um pôntico central. A infraestrutura do grupo G1 foi confeccionada em Ni-Cr, do grupo G2 em zircônia e G3 fresada em cera e fundida em Ni-Cr. Em todos os grupos a desadaptação marginal vertical e horizontal (subcontorno e sobrecontorno) foi avaliada através de um microscópio óptico tridimensional (Quick Scope, Mitutoyo). A revisão sistemática seguiu o critério PRISMA e está cadastrada na plataforma PROSPERO (CRD81865) e a busca foi realizada nas bases de dados Pubmed/MEDLINE, Embase and The Cochrane Library com artigos publicados até novembro de 2017. A questão PICO foi: "A técnica do ponto de solda contribui para uma melhor adaptação quando comparada a confecção em monobloco de infraestruturas e próteses fixas implantossuportadas?". O estudo in vitro demonstrou maior ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the marginal vertical, horizontal and internal misfit of implant-supported prostheses made through different techniques. In addition, to perform a systematic review and meta-analysis evaluating the effect of the welding technique on fixed prosthesis implants supported in make a better adaptation when compared the infrastructures made in one piece cast. A total of 30 infrastructures were made and divided into 3 groups: G1) Conventional- lost wax technique (n = 10); G2) CAD/CAM (n = 10); G3: CAD/CAM + lost wax technique (n = 10). A reference model was used to to simulate a 3-unit implant-supported fixed prostheses with a central pontic. In the G1 group the frameworks were made of Ni-Cr alloy, G2 group in zirconia and G3 milled in wax and fused in Ni-Cr alloy. In all groups, vertical and horizontal marginal misfit (under-contour and over-contour) was evaluated using a 3D optical microscope (Quick Scope, Mitutoyo, Japan). The systematic review and meta-analysis followed the PRISMA criteria and is registered on the PROSPERO (CRD81865). The search was performed in the Pubmed/MEDLINE, Embase and The Cochrane Library databases with selection of articles published until November 2017. The PICO question was: "The welding technique contributes to a better adaptation when compared to the one-piece cast frameworks of implant-supported prostheses?" The in vitro study showed a higher value of vertical marginal misfit for the G3 group (83.5μm), followed ... (Complete abstract click electronic access below) / Mestre
17

Efeito do design da união soldada a TIG e a laser, em estruturas usinadas em liga de Ti-6AI-4V e fundidas em titânio comercialmente puro, sobre a resistência à ciclagem mecânica / Effect of TIG and laser welded joints with different designs executed in machined Ti-6Al-4V and casted pure titanium strutures on the mechanical cycling resistance

Nuñez-Pantoja, Juliana Maria Costa 17 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T15:29:22Z (GMT). No. of bitstreams: 1 Nunez-Pantoja_JulianaMariaCosta_D.pdf: 1479308 bytes, checksum: ee8715e20b041116b795969befba2c72 (MD5) Previous issue date: 2011 / Resumo: Este estudo avaliou a resistência à ciclagem mecânica de estruturas confeccionadas em liga de Ti-6Al-4V e em Ti cp, submetidas à soldagem a laser (L) e ao procedimento TIG de soldagem (TIG), com variação de design das uniões, e correlacionar esses resultados com dados obtidos na análise radiográfica dessas soldas. Para o primeiro ensaio, foram obtidos 70 corpos de prova (halteres) usinados em liga de Ti-6Al-4V, com 3,5 mm de diâmetro de secção transversal e, para o segundo ensaio, outros 70 foram fundidos em Ti cp. Os corpos de prova foram seccionados em duas partes iguais e as partes a serem unidas foram limpas e alinhadas, segundo os designs da união: em "I", variando as distâncias de soldagem (0,0mm (I00) ou 0,6mm (I06)), ou em "X" (X). As variáveis design da união e tipo de soldagem foram cruzadas entre si formando um total de 6 grupos, que associadas ao grupo controle (intactos) totalizaram 7 grupos (n=10): G1- Intacto; G2- L/I00; G3- L/I06; G4- L/X; G5- TIG/I00; G6- TIG/I06; G7- TIG/X, para cada ensaio. Os corpos de prova foram soldados a laser utilizando-se 360V/8ms (X) e 390V/9ms (I00 e I06), com foco e freqüência regulados em zero. As soldas TIG foram realizadas utilizando-se os seguintes parâmetros de soldagem: 2:2 (X) e 3:2 (I00 e I06). As uniões receberam acabamento, polimento e foram submetidas à análise radiográfica (90 kV, 15 mA, 0,6 seg e 12 mm de distância), para verificação de poros no interior das soldas. Posteriormente, foi realizado o ensaio de resistência à ciclagem mecânica, e o número de ciclos até a fratura foi registrado. As superfícies de fratura foram analisadas em microscópio eletrônico de varredura. Os testes de Kruskal-Wallis e Dunn (?=0,05) mostraram que para ambos os procedimentos de soldagem, a pior maneira de se realizar a união se dá com I00, e a melhor, com X (p<0,05), para ambos os metais. Apenas para L, I06 foi tão resistente quanto X, tanto para o Ti cp quanto para Ti-6Al-4V. Quando são comparados os dois procedimentos de união, para os dois materiais, o teste de Mann-Whitney (?=0,05) mostrou haver diferença entre as soldas para I00 e I06, sendo que a união soldada a laser foi a mais resistente. Quando foram comparados os grupos com seus respectivos controles, notou-se que para o Ti-6Al-4V, nenhum grupo soldado foi tão resistente quanto os intactos; já para o Ti cp, os grupos com design X, para as duas soldas, foram tão resistentes quanto o controle, assim como o I06 soldado a laser. O coeficiente de correlação de Spearman (?=0,05) indicou correlação negativa entre número de ciclos resistidos e presença de poros nas radiografias das uniões dos materiais testados. Pode-se concluir que a união soldada com design em "X" dev0e ser empregada quando se pretende soldar a TIG corpos de prova de 3,5 mm de diâmetro de secção transversal. Quando é empregada a solda a laser, pode ser utilizado o design em "I" com 0,6 mm de espaçamento entre as partes, além do design em "X". / Abstract: The aim of this study was to evaluate the fatigue strength of Ti-6Al-4V alloy and pure titanium (cp TI) structures, submitted to laser (L) and TIG (TIG) welding procedures, varying the design of the joints, and correlate these results with joints radiographic analyses data. For the first test, 70 dumbbell rods with central diameters of 3.5 mm were obtained by lost-wax casting procedure in cp Ti, and others 70 were machined in Ti-6Al-4V alloy, for the second test. The specimens were sectioned in 2 equal parts, perpendicular to the rods long axis. The parts to be weld were cleaned and aligned according to joint designs: "I" design, varying welding distances (0.0 mm (I00) or 0.6 mm (I06)), or "X" (X) design. The variables joint design and type of welding were crossed creating 6 groups, that associated to the control group (intact), totaled 7 groups (n=10): G1- Intact; G2- L/I00; G3- L/I06; G4- L/X; G5- TIG/I00; G6- TIG/I06; G7- TIG/X, to each test. Laser-welding was executed using 360V/8ms (X) and 390V/9ms (I00 e I06) with focus and frequency regulated at zero. The TIG welding were executed using 2:2 (X) and 3:2 (I00 and I06) as welding parameters. The joints were finished, polished and submitted to radiographic examination (90 kV, 15 mA, 0.6 second and 12 mm of distance), for pores verification within the joints. Later, the rods were submitted to mechanical cyclic tests, and the number of cycles until fracture was recorded. The fracture surface was examined with a scanning electron microscope. Kruskal-Wallis and Dunn test (?=0.05) indicated that for both welding procedures, the worst way to perform the joint occurs with I00, and the best, with X (p<0.05), for both metals. To L, I06 was as resistant as X. When both type of welding are compared, to both materials, the Mann-Whitney test (?=0.05) indicates difference to I00 and I06, being the laser-weld joint the better one. When groups were compared with their respective control groups, it was noticed for Ti-6Al-4V that none of the joint groups was as resistant as the intact; on the contrary to cp Ti the "X" design groups, welded by TIG or L were as resistant as control, even as I06 laser-welded. The Spearman correlation coefficient (?=0.05) indicated a negative correlation between number of cycles and presence of porosity in radiographies of both materials. It could be concluded that the "X" design can be employed to weld 3.5 mm in diameter structures by laser or TIG welding procedure. When laser welding procedure is used, the "I" design with a space of 0.6 mm between parts can also be employed. / Doutorado / Protese Dental / Mestre em Clínica Odontológica

Page generated in 0.0234 seconds