Análise numérica de vigas mistas de madeira e concreto em situação de incêndio / Numerical analysis of timber-concrete composite beams in fire situation

Fernandes, Felipi Pablo Damasceno 10 May 2018 (has links)
As vigas mistas de madeira e concreto são formadas pela união de vigas de madeira a lajes de concreto armado por meio de conectores de cisalhamento. Quando os pisos mistos de madeira e concreto são comparados aos pisos construídos unicamente em madeira ou àqueles confeccionados somente em concreto armado é possível destacar algumas vantagens, incluindo o bom desempenho em situações de incêndio. Os elementos estruturais quando submetidos a ações térmicas sofrem redução de resistência e rigidez, sendo, desta forma, necessário conhecer as modificações sofridas por cada um de seus componentes, que para o caso estudado são: a madeira, o concreto e os conectores de cisalhamento. Desta forma, foi elaborada uma estratégia de modelagem numérica para o estudo de vigas mistas de madeira e concreto em situação de incêndio, utilizando o programa computacional ABAQUS, o qual é baseado no método dos elementos finitos. Em uma primeira etapa da pesquisa foram realizadas modelagens numéricas de vigas de madeira e mistas de madeira e concreto em temperatura ambiente, encontrando-se boa correlação entre as curvas força versus deslocamento no meio do vão obtida numericamente e por meio de ensaios disponíveis na literatura. Em seguida procedeu-se a calibração das propriedades térmicas e mecânicas da madeira brasileira, alcançando-se resultados numéricos próximos aos experimentais, seja em relação às temperaturas do elemento analisado seja em relação à curva de deslocamento vertical em função do tempo de incêndio. Por fim, a estratégia de modelagem termoestrutural desenvolvida para a viga mista de madeira e concreto forneceu curva de deslocamento vertical em função do tempo de incêndio semelhante à curva obtida por meio de modelo analítico disponível na literatura. Por meio do modelo elaborado foi possível observar que a elevação do nível de carregamento reduz o tempo de resistência do elemento estrutural e que a proteção térmica do concreto é essencial para aumentar o tempo até a ruptura da viga. / Timber-concrete composite beams are formed by the union of timber beams to reinforced concrete slabs through of shear connectors. When timber-concrete composite floors are compared to timber floors or reinforced concrete floors it is possible to highlight some advantages, including good performance in fire situations. When subjected to thermal actions, structural elements suffer strength and stiffness reductions, being, therefore, necessary to know the modifications suffered by each of its components, which for the case studied are: timber, concrete and shear connectors. Thus, it is developed a numerical modeling strategy using the computational program ABAQUS, which is based on the finite element method, for the study of timber-concrete composite beams in fire situation. In the first stage of the research it was carried out a numerical modeling of timber beam and timber-concrete composite beam at room temperature, finding good correlation between the force versus displacement curves in the middle of the span obtained numerically and through tests available in the literature. Then, it was carried out the calibration of the thermal and mechanical properties of the Brazilian wood, reaching numerical results close to the experimental ones, either in relation to the temperatures of the analyzed element or in relation to the vertical displacement curve as a function of the fire time. Finally, the thermo-structural modeling strategy developed for the timber-concrete composite beam provided a vertical displacement curve as a function of the fire time similar to the curve obtained through an analytical model available in the literature. Through of the elaborated model it was possible to observe that the load level increase reduces the resistance fire time of the structural element and that the thermal protection of the concrete is essential to increase the rupture time of the beam.
12

Avaliação da resistência ao fogo de paredes de alvenaria de blocos cerâmicos com instalações prediais

Bueno, Guilherme Manfredini 17 January 2019 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2019-03-22T17:02:16Z No. of bitstreams: 1 Guilherme Manfredini Bueno_.pdf: 3882428 bytes, checksum: 21f15ed53f487897437091a0f77fdfc5 (MD5) / Made available in DSpace on 2019-03-22T17:02:16Z (GMT). No. of bitstreams: 1 Guilherme Manfredini Bueno_.pdf: 3882428 bytes, checksum: 21f15ed53f487897437091a0f77fdfc5 (MD5) Previous issue date: 2019-01-17 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / itt Performance - Instituto Tecnológico em Desempenho da Construção Civil / Situações de incêndio possuem um grande potencial destrutivo para a sociedade. Um esforço significativo tem sido feito no Brasil para a avaliação da resistência ao fogo de alguns elementos. Entretanto, em relação às paredes de vedação ou com função estrutural, compostas por alvenarias de tijolos ou blocos, gesso ou concreto, há poucos estudos acadêmicos no país em escala real e ainda não foram feitas pesquisas com elementos de instalações prediais no interior de sistemas de compartimentação. Isto evidencia a importância desta pesquisa que buscou avaliar a resistência ao fogo de paredes através da ABNT NBR 10636: 1989, verificando a influência de aberturas destinadas a instalações elétricas e hidráulicas. Para atingir o objetivo proposto, foram confeccionadas amostras em escala real e ensaiadas no forno vertical do Instituto Tecnológico em Desempenho e Construção Civil (itt Performance), levando em consideração a curva de aquecimento padrão ISO 834/99 para verificação dos critérios de estabilidade, estanqueidade e isolamento térmico. A amostra referência (P-1) fora executada com blocos cerâmicos e revestimento argamassado, não possuindo instalação predial e, para fins de comparação, a amostra 2 (P-2) possuía aberturas com dimensões de 120 mm x 80 mm, contendo caixas de PVC para tomadas e componentes elétricos e a amostra 3 (P-3) aberturas de diâmetro 30 mm no ponto de saída de água das instalações hidráulicas. Durante a etapa de caracterização dos materiais, foram encontradas variações nas propriedades da argamassas utilizadas no revestimento das amostras. Conforme os resultados experimentais, todas as paredes mantiveram sua estabilidade e estanqueidade durante os 240 minutos de ensaio, entretanto, a capacidade de isolar termicamente foi comprometida em determinado instante. A P-1, P-2 e P-3 foram qualificadas como TRF 134 minutos, TRF 124 minutos e P-3 com TRF 193 minutos, respectivamente. O desempenho da amostra referência (P-1) foi comprometido devido ao desplacamento do revestimento argamassado e o lascamento dos blocos cerâmicos no decorrer do ensaio, o que também ocorreu na P-2. Logo, não se pode isolar os efeitos combinados da dilatação térmica diferencial, do desplacamento do revestimento, lascamento do substrato cerâmico, das propriedades dos materiais empregados, assim como da transferência de calor pelas aberturas nas amostras com instalações, que influenciaram no desempenho das paredes. Concluiu-se que, nas regiões com aberturas de instalações prediais que permitem a passagem de gases quentes, a superfície não exposta às altas temperaturas perde sua capacidade de isolamento em um menor tempo em comparação à superfície no entorno, o que reduz a resistência ao fogo de sistemas de compartimentação / Fire situations have great destructive potential for society. A significant effort has been made in Brazil to evaluate the fire resistance of some elements. However, regarding walls, composed of masonry bricks or blocks, plaster or concrete, there are few national academic studies in full scale and no research has been done with elements of buildings built inside partitioning systems. This implies the urge of this research that sought to evaluate the performance of compartmentation walls with a fire resistance rate function, verifying the influence of openings for electrical and hydraulic installations. In order to reach the proposed objective, full scale samples were constructed and tested according to the ABNT NBR 10636:1989 in the vertical furnace of the Technological Institute in Civil Construction Performance (itt Performance - UNISINOS), taking into consideration the ISO 834/14 standard heating curve to verify stability, sealing and thermal insulation criteria. The reference sample (P-1) was performed with clay blocks and coating mortar, without any type of building installation, and for comparison purposes, sample 2 (P-2) contained openings with dimensions of 120 mm x 80 mm, containing electrical installations and sample 3 (P-3) openings of 30 mm diameter for hydraulic installations. During the materials characterization stage, there were variations in the properties of the mortars used in the coating of the samples. According to the experimental results, all systems maintained their stability and sealing during the 240 minutes of test, however, the ability to thermally insultating was compromised at a certain moment. P- 1, P-2 and P-3 were qualified as TRF 134 minutes, TRF 124 minutes and P-3 with TRF 193 minutes, respectively. The performance of the reference sample (P-1) was compromised due to the mortar coating displacement and spalling of the blocks. Therefore, it is not possible to isolate the combined effects of the thermal expansion, coating displacement, spalling of the ceramic blocks, the properties of the materials employed, as well as the heat transfer from the openings in the samples with installations, which influenced in the performance of the walls. It was concluded that in regions with openings of building installations that allow the passage of hot gases, the surface not exposed to high temperatures loses its insulation capacity in a shorter time compared to the surrounding surface, which reduces the fire resistance of the compartmentation systems.
13

Avaliação experimental da influência dos requisitos de durabilidade na segurança contra incêndio de protótipos de pilares pré-fabricados de concreto armado

Bolina, Fabricio Longhi 24 February 2016 (has links)
Submitted by Silvana Teresinha Dornelles Studzinski (sstudzinski) on 2016-05-11T15:43:54Z No. of bitstreams: 1 FABRICIO LONGHI BOLINA_.pdf: 12122006 bytes, checksum: 94b786347b29331df85e06c63ee3a387 (MD5) / Made available in DSpace on 2016-05-11T15:43:54Z (GMT). No. of bitstreams: 1 FABRICIO LONGHI BOLINA_.pdf: 12122006 bytes, checksum: 94b786347b29331df85e06c63ee3a387 (MD5) Previous issue date: 2016-02-24 / Nenhuma / As recentes tragédias ocorridas no Brasil motivaram a revisão de leis e diretrizes sobre segurança contra incêndio das edificações. Paralelamente, novos requisitos de segurança foram exigidos pela norma de desempenho (ABNT, 2013a), fortalecendo o debate. Estes fatores, reforçados pela intensificação da fiscalização e das exigências para o licenciamento edilício, acentuou o dever de prever a segurança contra incêndio em projeto. Nas estruturas de concreto, as normas que definem as especificações de durabilidade, a NBR 6118 (ABNT, 2014) e NBR 12655 (ABNT, 2015), não consentem os parâmetros de segurança contra incêndio da NBR 15200 (ABNT, 2012), e vice-versa. Este trabalho visa avaliar, experimentalmente, o tempo de resistência ao fogo (TRF) de protótipos de pilares pré-fabricados produzidos com parâmetros normativos de durabilidade do concreto, comparando-os com as recomendações da NBR 15200 (ABNT, 2012). O estudo foi feito em 16 pilares, 4 para cada classe de agressividade ambiental, com seção transversal 25x25cm e altura 300cm, com diferentes classes de resistência e produzidos numa indústria de pré-fabricados, ensaiados na idade de 28 dias por 240 minutos, sem carregamento, com a curva de aquecimento da ISO 834 (ISO, 2014). Para cada pilar de mesma classe, uma espessura de cobrimento distinta foi adotada. Concluiu-se que os parâmetros de durabilidade do concreto influenciaram no grau de desplacamento, havendo, contudo, preponderância do diâmetro das barras e da espessura de cobrimento no TRF destes pilares. Os maiores diâmetros, apesar de desenvolverem temperaturas médias menores durante o ensaio, intensificaram o desplacamento de aresta, que aumentou em paralelo com a resistência à compressão nos concretos de até 63MPa, diminuindo nas resistências superiores a esta. O método analítico de verificação da NBR 15200 (ABNT, 2012) se mostrou seguro, notando-se um grau de conservadorismo intrínseco. Após o ensaio, as armaduras principais e o concreto apresentaram perda residual de resistência. / Recent tragedies in Brazil have set off a revision of laws and technical practices on fire safety in buildings. At the same time, new security requirements have become required by the brazilian performance standard (ABNT, 2013). This set of factors, enhanced by strong supervision and project approval requirements, intensified the commitment to provide fire safety in the initial design of buildings, along with other design requirements. In concrete structures, the standards that stablish the durability specifications - the NBR 6118 (ABNT, 2014) and NBR 12655 (ABNT, 2015), do not cogitate the parameters of fire safety design of the NBR 15200 (ABNT, 2012), and vice versa. This study aims to evaluate the fire resistance time of elements produced with standard durability parameters, comparing them with the NBR 15200 (ABNT, 2012) criteria. The experiment was done on 16 columns, 4 for each standard environmental aggressiveness class, with cross section of 25x25 cm and a height of 300 cm, with different resistance classes and produced in a industry, tested at the age of 28 days for 240 minutes without load, with temperature evolution attending to the ISO 834 (ISO 2014) curve. Moreover, a different thickness of concrete cover was used for each column with the same environmental aggression class. The results showed that the durability parameters influence the degree of spalling, whereas the nominal diameter and the thickness of concrete cover have greater importance in fire resistance time. While the biggest diameters of the bars produced lower temperatures, they intensified the degree of spalling that simultaneously increased with the compressive strength of the concrete up to 63MPa. The analytical verification method of NBR 15200 (ABNT, 2012) proved to be safe, with a degree of intrinsic conservatism. The reinforcement and the concrete had residual loss of strength.
14

Análise numérica de vigas mistas de madeira e concreto em situação de incêndio / Numerical analysis of timber-concrete composite beams in fire situation

Felipi Pablo Damasceno Fernandes 10 May 2018 (has links)
As vigas mistas de madeira e concreto são formadas pela união de vigas de madeira a lajes de concreto armado por meio de conectores de cisalhamento. Quando os pisos mistos de madeira e concreto são comparados aos pisos construídos unicamente em madeira ou àqueles confeccionados somente em concreto armado é possível destacar algumas vantagens, incluindo o bom desempenho em situações de incêndio. Os elementos estruturais quando submetidos a ações térmicas sofrem redução de resistência e rigidez, sendo, desta forma, necessário conhecer as modificações sofridas por cada um de seus componentes, que para o caso estudado são: a madeira, o concreto e os conectores de cisalhamento. Desta forma, foi elaborada uma estratégia de modelagem numérica para o estudo de vigas mistas de madeira e concreto em situação de incêndio, utilizando o programa computacional ABAQUS, o qual é baseado no método dos elementos finitos. Em uma primeira etapa da pesquisa foram realizadas modelagens numéricas de vigas de madeira e mistas de madeira e concreto em temperatura ambiente, encontrando-se boa correlação entre as curvas força versus deslocamento no meio do vão obtida numericamente e por meio de ensaios disponíveis na literatura. Em seguida procedeu-se a calibração das propriedades térmicas e mecânicas da madeira brasileira, alcançando-se resultados numéricos próximos aos experimentais, seja em relação às temperaturas do elemento analisado seja em relação à curva de deslocamento vertical em função do tempo de incêndio. Por fim, a estratégia de modelagem termoestrutural desenvolvida para a viga mista de madeira e concreto forneceu curva de deslocamento vertical em função do tempo de incêndio semelhante à curva obtida por meio de modelo analítico disponível na literatura. Por meio do modelo elaborado foi possível observar que a elevação do nível de carregamento reduz o tempo de resistência do elemento estrutural e que a proteção térmica do concreto é essencial para aumentar o tempo até a ruptura da viga. / Timber-concrete composite beams are formed by the union of timber beams to reinforced concrete slabs through of shear connectors. When timber-concrete composite floors are compared to timber floors or reinforced concrete floors it is possible to highlight some advantages, including good performance in fire situations. When subjected to thermal actions, structural elements suffer strength and stiffness reductions, being, therefore, necessary to know the modifications suffered by each of its components, which for the case studied are: timber, concrete and shear connectors. Thus, it is developed a numerical modeling strategy using the computational program ABAQUS, which is based on the finite element method, for the study of timber-concrete composite beams in fire situation. In the first stage of the research it was carried out a numerical modeling of timber beam and timber-concrete composite beam at room temperature, finding good correlation between the force versus displacement curves in the middle of the span obtained numerically and through tests available in the literature. Then, it was carried out the calibration of the thermal and mechanical properties of the Brazilian wood, reaching numerical results close to the experimental ones, either in relation to the temperatures of the analyzed element or in relation to the vertical displacement curve as a function of the fire time. Finally, the thermo-structural modeling strategy developed for the timber-concrete composite beam provided a vertical displacement curve as a function of the fire time similar to the curve obtained through an analytical model available in the literature. Through of the elaborated model it was possible to observe that the load level increase reduces the resistance fire time of the structural element and that the thermal protection of the concrete is essential to increase the rupture time of the beam.
15

Educação e gestão da segurança contra incêndio: estudo de caso dos ambientes audiovisuais de uma Instituição Federal de ensino. / Education and fire safety management: a case study research in fire awareness of audiovisual installations at public education institution

Santos, Marco Aurélio Araujo dos 23 February 2018 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2018-08-10T13:00:10Z No. of bitstreams: 1 Marco Aurelio Araujo dos Santos.pdf: 17624457 bytes, checksum: a39f334c6d3e733c0e16c8355eb7e4a3 (MD5) / Made available in DSpace on 2018-08-10T13:00:10Z (GMT). No. of bitstreams: 1 Marco Aurelio Araujo dos Santos.pdf: 17624457 bytes, checksum: a39f334c6d3e733c0e16c8355eb7e4a3 (MD5) Previous issue date: 2018-02-23 / Every year, fires in public educational institutions and other public properties cause a substantial number of civilian deaths and injuries and significant property damage in the Brazil. This research is about Education and Fire Safety Management, linking it to the culture and occupational health and safety in an educational institution. This is a case study research in Fire Safety Awareness of audiovisual installations at federal educational institution. Fire Safety Management failures in public schools or colleges & universities to focus on prevention and control methods of fire suppression interfere with the efficient fire suppression, for educational institutions where there might be limited resources or high risk in case of fire to extinguish or prevent the spread of fire. The aim of this research is to promote the Fire Safety Awareness, Safety Culture, to identify future safety failures leads to improved planning, and raising environmental awareness and providing information through education to employees and students. The following culture types were then analyzed: school culture, organizational culture and safety culture. Implications of these three theoretical perspectives for the ways sociologists think about the theoretical contributions of Critical Theory in the research was Adorno and Horkheimer’s concepts of culture and awareness, discussing the barriers to awareness and education. Finally, the research propose recommendations to improve the Fire Safety Management at federal educational institution. / Todos los años se registran diversos casos de incendios en edificios públicos en Brasil, muchas de estas ocurrencias se registran en las instituciones educativas públicas, causando diversos accidentes, muertes y daños materiales. Esta investigación tuvo como tema la educación y la gestión de la seguridad en caso de incendio, fue realizada en una institución federal educativa y presenta como problema la cuestión de la concientización de la comunidad de la institución para la implantación de una cultura de seguridad, partiendo de la hipótesis de que es posible un plan de gestión que considere un Programa de Prevención de Riesgos Ambientales e incentive la concientización de la comunidade de la seguridad en caso de incendio, a través de medidas educativas y culturales, buscando la prevención con base en las informaciones presentadas en la legislación vigente. El objetivo general de esta investigación es desarrollar el proceso de concientización y de implementación de un sistema de seguridad em caso de incendio en la institución, basado en la implantación de la cultura de la seguridad y en la legislación vigente, los objetivos específicos son: identificar y describir las principales fallas del sistema de la seguridad contra incendios en la institución de esta investigación, analizar cómo tales fallas interfieren en la gestión del sistema contra incendios de la institución y señalar interferencias necesarias de la administración sobre la concientización y la gestión del sistema de seguridad em caso de incêndio de la institución. En la investigación fueron evaluados, como muestreo, los ambientes audiovisuales y sus accesos, los sujetos de la investigación fueron servidores de la institución y alumnos. La metodología adoptada en este trabajo fue una investigación de naturaleza cualitativa, utilizando el método de un estudio de caso, realizado en la institución, por medio de recolección de datos, combinando el uso de técnicas de observación participante y entrevistas personales, en las cuales los instrumentos de observación recolección fueron los guiones de entrevistas y el grupo focal, que sirvieron al análisis de los resultados. El referencial teórico crítico fue la Teoría Crítica, por medio de los autores Horkheimer y Adorno para el fundamento teórico de los conceptos de cultura y concientización. Finalizando, la investigación trató de una recomendación de propuesta de intervención de la Gestión de la seguridad en caso de incendio. / Todos os anos são registrados diversos casos de incêndios em edificações públicas no Brasil, muitas destas ocorrências são registradas em instituições de ensino públicas, causando diversos acidentes, mortes e danos materiais. Este trabalho tem como tema a Educação e a Gestão da Segurança Contra Incêndio, foi realizado em uma instituição federal de ensino e apresenta como problema a questão da conscientização da comunidade do campus para a implantação de uma cultura de segurança, que possa gerir de forma eficiente a segurança contra incêndio, partindo da hipótese de que é possível um plano de gestão que considere um Programa de Prevenção de Riscos Ambientais e incentive a conscientização da comunidade, por meio de medidas educativas e culturais, visando a prevenção com base nas informações apresentadas na legislação vigente. O objetivo geral desta pesquisa é desenvolver o processo de conscientização e de implementação de um sistema de segurança contra incêndios no campus, baseado na implantação da cultura de segurança e na legislação vigente, os objetivos específicos são: identificar e descrever as principais falhas do sistema de segurança contra incêndio na instituição desta pesquisa, analisar como tais falhas interferem na gestão do sistema contra incêndios do campus e apontar interferências necessárias da administração sobre a conscientização e a gestão do sistema de segurança contra incêndio. Na pesquisa foram avaliados, como amostragem, os ambientes audiovisuais e seus acessos, os sujeitos da pesquisa foram servidores da instituição e alunos. A metodologia adotada neste trabalho foi uma pesquisa de natureza qualitativa, utilizando o método de um estudo de caso, realizado na instituição, por meio de coleta de dados, combinando o uso de técnicas de observação participante e entrevistas pessoais, nas quais os instrumentos de coleta foram os roteiros de entrevistas e o grupo focal, que serviram à análise dos resultados. O referencial teórico crítico é a Teoria Crítica, por meio dos autores Horkheimer e Adorno para o embasamento teórico dos conceitos de cultura e conscientização. Finalizando, a investigação recomendou uma proposta de intervenção na Segurança Contra Incêndio do campus.
16

Comportamento de crianças em movimento em escadas: subsí­dios para o dimensionamento dos meios de escape em escolas / Dado não fornecido pelo autor.

Valentim, Marcos Vargas 17 August 2018 (has links)
A norma brasileira que trata de Saídas de Emergência, a ABNT NBR 9077:2001, pressupõe que o perfil da população de alunos em edifícios escolares, do ensino fundamental à universidade, é homogêneo, e que, portanto, não há eventuais particularidades inerentes às diferentes faixas etárias no uso das saídas de emergência. Esta pesquisa partiu da hipótese de que o perfil da população e, em particular, o de crianças do ciclo básico do ensino fundamental, pode ser diferente do adulto e, por consequência, demandar um dimensionamento específico para as saídas de emergência. Assim, realizou-se a coleta e análise de dados relativos à velocidade de caminhamento e aspectos comportamentais de crianças no movimento de descida de escadas, além de buscar correlações entre as velocidades e os dados antropométricos. Participaram da pesquisa 783 alunos do ciclo básico do ensino fundamental, oriundos de três escolas de ensino gratuito, com idade entre 6 e 10 anos. Foram testadas duas técnicas para a coleta dos dados: filmagens obtidas por meio de sistema fechado de televisão (CFTV) e sistema de identificação por rádio frequência (RFID), sendo que essa última não atendeu às expectativas e necessidades da pesquisa. As velocidades obtidas por processamento de dados de filmagens foram comparadas com as adotadas nos softwares de simulação de abandono \"FDS+EVAC\" e \"Simulex\". Constatou-se que, para os lances das escadas, as velocidades das crianças obtidas se assemelham as de referência de adultos (0,45 m/s até 1,05 m/s). Já para a velocidades obtidas nos patamares, houve grande dispersão, em relação aos valores de referência para adultos e crianças. Verificou-se, também, que o trajeto mais utilizado nos patamares foi o interno (mais curto) e que o emprego de métodos simplificados para estimar esses trajetos pode resultar em dados de velocidade imprecisos. Não foi constatada nenhuma correlação significativa entre as medidas antropométricas (IMC e bideltóide) e as velocidades dos alunos em lances ou patamares de escadas. Devido a dispersão dos resultados obtidos, não é possível a confirmação da hipótese inicial desta pesquisa. / In the Brazilian Technical Standard concerning means of egress (ABNT NBR 9077. 2001) it is presumed that the profile of students\' population in educational buildings, from elementary school to college, is homogeneous. Therefore, it does not consider the eventual particularities intrinsic to specific age groups during the use of egress systems. Assuming that the profile of elementary school children may be different from adults\', the criteria applicable to a variety of means of egress components could be more specific according to the occupant\'s characteristics. Thus, data regarding walking speeds and behavioral aspects of children in descending movement of stairs were collected and analyzed. Anthropometric data (weight, height and bideltoid measurement) from each child were also collected in order to seek correlations between these dimensions and the walking speeds. 783 elementary students from 3 different public schools, ages varying from 6 to 10 years old, participated in this research. Two techniques were tested for collecting data: recorded images from closed-circuit television (CCTV) and signals from radio-frequency identification (RFID); however, the last one was discarded due to technical difficulties. When compared to the speeds adopted by the egress simulation softwares \"FDS+EVAC\" and \"Simulex\", it was noticed that children\'s travel speeds in stairs are actually quite similar to the ones adopted for adults (0,45 m/s to 1,05 m/s), contrasting with the common sense that infants are slower than grown-ups. As for the walking speeds on landings, a wide dispersion in relation to parameters determined for adults and children was found. It was also noticed that most infants chose the shortest path (internal) on landings and that designation of a simplified average trajectory can lead to inaccurate travel speeds. Regarding the anthropometric measurements and walking speeds, no direct correlation was found. Due to the significant dispersion of the results, the initial hypothesis of this research could not be confirmed.
17

Análise numérica e experimental de vigas de madeira laminada colada em situação de incêndio / Numerical and experimental analysis of glued laminated timber in fire situation

Martins, Gisele Cristina Antunes 29 July 2016 (has links)
Elementos estruturais de Madeira Laminada Colada (MLC) têm sido muito utilizados na América do Norte e na Europa. Entretanto no Brasil há restrições quanto ao uso, principalmente, em razão da insegurança diante de potenciais riscos relacionados a incêndios. Este trabalho investigou o comportamento térmico e mecânico de elementos estruturais de MLC expostos à curva de incêndio-padrão ISO 834, preparados com duas espécies de madeira (Eucalyptus e Pinus) sem adição de tratamentos preservantes. Adicionalmente, elementos tratados com preservante ignífugo a base Borato de Cobre Cromatado (MOQ® OX 50CCBO) ou tratamento retardantes ao fogo (OSMOGUARD® FR100) também foram utilizados para analisar a influência na carbonização. O objetivo principal da pesquisa foi analisar a resistência ao fogo de elementos de MLC, avaliando a influência da espécie de madeira, a influência da densidade, bem como os efeitos dos tratamentos preservantes. O programa experimental foi realizado no forno horizontal a gás instalado no Departamento de Engenhara das Estruturas - EESC/USP, com dimensões internas de 3m x 4m x 1,5m, e as análises numéricas foram implementadas no pacote computacional ABAQUS. O modelo numérico, com vistas ao monitoramento a deflexão no meio do vão e a avaliação da distribuição da temperatura ao longo da profundidade dos elementos, foram desenvolvidos e os resultados obtidos foram comparados com os dados obtidos por meio das análises experimentais. Métodos de cálculo propostos por diferentes autores e regulamentações internacionais foram aplicados para verificação das propostas de dimensionamento em situação de incêndio. A comparação dos resultados mostrou que a utilização dos métodos de dimensionamento (simplificado ou avançado) representa risco à segurança contra incêndio caso utilize valores para a taxa de carbonização das espécies nacionais determinados a partir dos métodos de cálculo ou normas internacionais. / Structural elements of Glued Laminated Timber (glulam) have long been used in North America and Europe, but their use is still restricted in Brazil for safety reasons, especially related to potential risks in face of fire. The present work investigated the thermal and mechanical behavior of structural elements of glulam exposed to fire standard ISO 834. The glued laminated timber was produced from two wood species (Eucalyptus and Pinus) without any treatments. However, elements treated with wood treatments like Copper Chrome Boron (MOQ® OX 50 -CCB-O) or fire retardant treatment (OSMOGUARD® FR100) were also used to investigate their influence on charring. The main objective of this study was to assess the fire resistance of the glulam elements, evaluating the influence of wood species and, consequently, the influence of density, as well as the effects of preservative treatment. The experimental program was carried out in a gas oven, with internal dimensions of 3m x 4m x 1.5m, and the numerical analyses were performed by ABAQUS. The numerical analyses aimed to monitor the deflection in the middle of the span as well as the temperature distribution along the depth of the elements. The results obtained from both the experimental and numerical analyses were compared. Calculation methods proposed by different authors and international regulations have been applied for verification of the proposed design in fire. A comparison of the results show that the use of calculation methods (simplified and advanced) represents a risk to fire safety in case of using the values of char rate for Brazilian wood species determined from the calculation methods.
18

Análise numérica e experimental de vigas de madeira laminada colada em situação de incêndio / Numerical and experimental analysis of glued laminated timber in fire situation

Gisele Cristina Antunes Martins 29 July 2016 (has links)
Elementos estruturais de Madeira Laminada Colada (MLC) têm sido muito utilizados na América do Norte e na Europa. Entretanto no Brasil há restrições quanto ao uso, principalmente, em razão da insegurança diante de potenciais riscos relacionados a incêndios. Este trabalho investigou o comportamento térmico e mecânico de elementos estruturais de MLC expostos à curva de incêndio-padrão ISO 834, preparados com duas espécies de madeira (Eucalyptus e Pinus) sem adição de tratamentos preservantes. Adicionalmente, elementos tratados com preservante ignífugo a base Borato de Cobre Cromatado (MOQ® OX 50CCBO) ou tratamento retardantes ao fogo (OSMOGUARD® FR100) também foram utilizados para analisar a influência na carbonização. O objetivo principal da pesquisa foi analisar a resistência ao fogo de elementos de MLC, avaliando a influência da espécie de madeira, a influência da densidade, bem como os efeitos dos tratamentos preservantes. O programa experimental foi realizado no forno horizontal a gás instalado no Departamento de Engenhara das Estruturas - EESC/USP, com dimensões internas de 3m x 4m x 1,5m, e as análises numéricas foram implementadas no pacote computacional ABAQUS. O modelo numérico, com vistas ao monitoramento a deflexão no meio do vão e a avaliação da distribuição da temperatura ao longo da profundidade dos elementos, foram desenvolvidos e os resultados obtidos foram comparados com os dados obtidos por meio das análises experimentais. Métodos de cálculo propostos por diferentes autores e regulamentações internacionais foram aplicados para verificação das propostas de dimensionamento em situação de incêndio. A comparação dos resultados mostrou que a utilização dos métodos de dimensionamento (simplificado ou avançado) representa risco à segurança contra incêndio caso utilize valores para a taxa de carbonização das espécies nacionais determinados a partir dos métodos de cálculo ou normas internacionais. / Structural elements of Glued Laminated Timber (glulam) have long been used in North America and Europe, but their use is still restricted in Brazil for safety reasons, especially related to potential risks in face of fire. The present work investigated the thermal and mechanical behavior of structural elements of glulam exposed to fire standard ISO 834. The glued laminated timber was produced from two wood species (Eucalyptus and Pinus) without any treatments. However, elements treated with wood treatments like Copper Chrome Boron (MOQ® OX 50 -CCB-O) or fire retardant treatment (OSMOGUARD® FR100) were also used to investigate their influence on charring. The main objective of this study was to assess the fire resistance of the glulam elements, evaluating the influence of wood species and, consequently, the influence of density, as well as the effects of preservative treatment. The experimental program was carried out in a gas oven, with internal dimensions of 3m x 4m x 1.5m, and the numerical analyses were performed by ABAQUS. The numerical analyses aimed to monitor the deflection in the middle of the span as well as the temperature distribution along the depth of the elements. The results obtained from both the experimental and numerical analyses were compared. Calculation methods proposed by different authors and international regulations have been applied for verification of the proposed design in fire. A comparison of the results show that the use of calculation methods (simplified and advanced) represents a risk to fire safety in case of using the values of char rate for Brazilian wood species determined from the calculation methods.