• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 177
  • 13
  • 10
  • 1
  • Tagged with
  • 202
  • 124
  • 39
  • 35
  • 27
  • 23
  • 19
  • 17
  • 17
  • 17
  • 16
  • 15
  • 14
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Simulador de redes Profibus / Profibus network simulator

Torres, Renato da Veiga 19 September 2013 (has links)
Este trabalho propõe o desenvolvimento de um simulador de redes Profibus DP que reproduz o comportamento de uma rede real. A simulação de redes em condições de falha permite aos usuários experimental situações que podem ocorrer em instalações reais, facilitando o treinamento de manutenção e antecipando ações corretivas. O simulador permite o treinamento de usuários que utilizam ferramentas de diagnóstico. Auxilia no estudo do protocolo Profibus DP e também contribui com o desenvolvimento da ferramenta Profidoctor que é um sistema especialista com o objetivo de fazer a análise de problemas de rede. / This work aims development of Profibus DP network simulator that reproduces real network behavior. The network simulation under fault conditions allows experiment situations that may occur in real network installations, helping in maintenance training and corrective actions. This simulator tool helps in diagnostic tool users training, Profibus DP protocol learning and also assists development of new tool Profidoctor: an expert system that will report complete analysis of network problems.
42

Reconstrução de objetos simuladores segmentados aplicáveis à dosimetria de pele / Reconstruction of voxel phantoms for skin dosimetry

Antunes, Paula Cristina Guimarães 09 December 2010 (has links)
A radioterapia é uma modalidade terapêutica que utiliza radiações ionizantes para erradicar as células neoplásicas do organismo humano. Um dos requisitos para o sucesso desta metodologia de tratamento está na utilização adequada dos sistemas de planejamento, os quais, dentre outras informações, estimam a dose a ser administrada aos pacientes. Atualmente, códigos de transporte de radiação têm proporcionado grandes subsídios a estes sistemas de planejamento, uma vez que viabilizam avaliações dosimétricas acuradas nos órgãos e tecidos específicos de um paciente. O modelo utilizado por estes códigos para descrever a anatomia humana de forma realista é denominado Objeto Simulador Segmentado (OSS), que consiste na representação das estruturas anatômicas do corpo em discretos elementos de volume (voxels), os quais são diretamente associados aos dados tomográficos. Atualmente, os OSS possíveis de serem inseridos e processados pelo código de transporte MCNP (Monte Carlo N-Particle), apresentam voxels com resoluções da ordem de 3-4 mm. No entanto, tal resolução compromete a discriminação de algumas estruturas finas do corpo, tais como a pele. Neste contexto, o presente estudo propõe a criação de uma rotina de cálculo que discrimine a região da pele, com espessura e localização próximas do real, nos OSS e os habilite para avaliações dosimétricas acuradas. A metodologia proposta consiste na manipulação dos elementos de volume dos OSS de forma a segmentá-los e subdividi-los em diferentes espessuras de pele. A fim de validar os dados obtidos por cálculos, foram realizadas avaliações experimentais de dosimetria de pele em objetos simuladores antropomórficos com dosímetros termoluminescentes. Verificou-se, ao longo deste estudo, a importância de discriminar a região da pele com localização e espessuras próximas do real, uma vez que foram encontradas diferenças significativas entre as estimativas de dose absorvida na região pelas diferentes representações. A metodologia proposta neste estudo far-se-á útil para avaliações dosimétricas acuradas da região de pele para diversos procedimentos radioterápicos, com particular interesse na radioterapia com feixe de elétrons, na qual se destaca a terapia de irradiação de corpo inteiro (TSET Total Skin Electron Therapy), procedimento radioterápico em implementação no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HC-FMUSP). / Radiotherapy is a therapeutic modality that utilizes ionizing radiation for the destruction of neoplastic human cells. One of the requirements for this treatment methodology success lays on the appropriate use of planning systems, which performs, among other information, the patients dose distribution estimate. Nowadays, transport codes have been providing huge subsidies to these planning systems, once it enables specific and accurate patient organ and tissue dosimetry. The model utilized by these codes to describe the human anatomy in a realistic way is known as voxel phantoms, which are represented by discrete volume elements (voxels) directly associated to tomographic data. Nowadays, voxel phantoms doable of being inserted and processed by the transport code MCNP (Monte Carlo N-Particle) presents a 3-4 mm image resolution; however, such resolution limits some thin body structure discrimination, such as skin. In this context, this work proposes a calculus routine that discriminates this region with thickness and localization in the voxel phantoms similar to the real, leading to an accurate dosimetric skin dose assessment by the MCNP code. Moreover, this methodology consists in manipulating the voxel phantoms volume elements by segmenting and subdividing it in different skin thickness. In addition to validate the skin dose calculated data, a set of experimental evaluations with thermoluminescent dosimeters were performed in an anthropomorphic phantom. Due to significant differences observed on the dose distribution of several skin representations, it was found that is important to discriminate the skin thickness similar to the real. The presented methodology is useful to obtain an accurate skin dosimetric evaluation for several radiotherapy procedures, with particular interest on the electron beam radiotherapy, in which highlights the whole body irradiation therapy (TSET), a procedure under implementation at the Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HC-FMUSP).
43

Desempenho em um simulador de dire??o e sua rela??o com a capacidade cognitiva em condutores idosos

Vasques, Adriana Machado 21 June 2017 (has links)
Submitted by PPG Gerontologia Biom?dica (geronbio@pucrs.br) on 2017-08-17T13:48:58Z No. of bitstreams: 1 VASQUES_ADRIANA_MACHADO.pdf: 2518120 bytes, checksum: 7a0b3e0350846d9ac6cc0584973c0a19 (MD5) / Rejected by Caroline Xavier (caroline.xavier@pucrs.br), reason: Devolvido devido a falta de capa institucional. on 2017-08-21T12:19:24Z (GMT) / Submitted by PPG Gerontologia Biom?dica (geronbio@pucrs.br) on 2017-08-21T17:07:52Z No. of bitstreams: 1 VASQUES_ADRIANA_MACHADO_TESE.pdf: 6462123 bytes, checksum: b1fc71519ef4d65f8d2f3ed44e760d5a (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-08-22T13:29:59Z (GMT) No. of bitstreams: 1 VASQUES_ADRIANA_MACHADO_TESE.pdf: 6462123 bytes, checksum: b1fc71519ef4d65f8d2f3ed44e760d5a (MD5) / Made available in DSpace on 2017-08-22T13:50:20Z (GMT). No. of bitstreams: 1 VASQUES_ADRIANA_MACHADO_TESE.pdf: 6462123 bytes, checksum: b1fc71519ef4d65f8d2f3ed44e760d5a (MD5) Previous issue date: 2017-06-21 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / With seniors increasing faster than younger populations, the average age of car drivers has gone up, and ageing-associated cognitive decline may interfere with the skills needed for safe driving. However, driving provides autonomy and quality of life, and being considered unfit to perform this task may restrict social life and lead to depression. As such, any restrictive measures should be based on careful assessment; however, the instruments available to evaluate the cognitive functions and the driving performance of the elderly need to be largely improved. Objective: To investigate the cognitive functions of elderly drivers and relate them to performance in a driving simulator, and to identify the most effective parameters of evaluation, thus contributing to traffic safety and to the creation of public policies. Method: This is a cross-sectional, descriptive-analytic study, involving 34 elderly drivers evaluated by a driving simulator and cognitive tests (Wechsler Intelligence Scale Codes, Divided Attention Test - TEADI, Trail Making test, Revised Addenbrooke Cognitive Examination - ACE-R and Rey Verbal Learning Test - RAVLT). Results: The tests that evaluate the cognitive functioning, especially those of verbal memory and the visuoconstructive abilities were the ones that demonstrated more relation with the performance in the driving simulator. Conclusions: The comparison between performance in cognitive tests and scores in the drive simulator shows a correlation between both, indicating that the worst performance in the simulator is associated with worse cognitive performance, proving to be a useful instrument to contribute to the evaluation of elderly drivers. / Com o aumento expressivo da popula??o idosa, cresce o n?mero de condutores automotivos em uma faixa et?ria frequentemente acometida por decl?nios cognitivos que podem interferir nas habilidades para uma condu??o segura. Sendo a condu??o automotiva essencial para a manuten??o da autonomia e qualidade de vida e sua interrup??o associada a efeitos negativos como restri??o ? vida social e aumento de sintomas depressivos, sua continuidade ou n?o deveria basear-se em uma avalia??o criteriosa. No entanto, apesar de relevante, ainda n?o foram estabelecidos os instrumentos mais eficazes para avaliar as fun??es cognitivas e o desempenho de idosos na condu??o automotiva. Objetivo: investigar as fun??es cognitivas de motoristas idosos e relacionar com o desempenho em um simulador de dire??o, buscando identificar os par?metros mais eficazes de avalia??o, contribuindo para seguran?a no tr?nsito e para a cria??o de pol?ticas p?blicas. M?todo: estudo do tipo transversal com abordagem descritivo-anal?tica, envolvendo 34 condutores idosos avaliados atrav?s de um simulador de dire??o e testes cognitivos (C?digos, da Escala de intelig?ncia Wechsler, Teste de aten??o Dividida-TEADI, Trail Making teste-TMT, Exame Cognitivo de Addenbrooke Revisado-ACE-R e Teste de aprendizado Verbal de Rey- RAVLT). Resultados: os testes que avaliam o funcionamento cognitivo, especialmente os de mem?ria verbal e as habilidades visuoconstrutivas foram os que mais demonstraram rela??o com o desempenho no simulador de condu??o. Conclus?es: a compara??o entre o desempenho nos testes cognitivos e os escores no simulador de dire??o, evidencia correla??o entre ambos, indicando que o pior desempenho no simulador associa-se ao pior desempenho cognitivo, revelando-se um instrumento ?til para contribuir na avalia??o de condutores idosos.
44

Aquisição de habilidades em cirurgia videolaparoscópica por residentes em cirurgia geral após treinamento em simulador de alta fidelidade

Lemos, Fernanda Maria Fernandes do Carmo 17 February 2016 (has links)
A demorada curva de aprendizado consome demasiado tempo dos docentes cirurgiões, pois exige rigorosa e prolongada monitoria didática aos residentes. As inovações no ensino na área da saúde, em conjunto com o avanço tecnológico, deram origem a simuladores cada vez mais sofisticados, despertando assim, maiores interesses pela simulação. A adoção do simulador de cirurgia de alta fidelidade (Lap VR) em aulas práticas com os residentes em cirurgia geral da Universidade Federal do Tocantins (UFT) visa dinamizar o aprendizado destes alunos, sendo um treinamento em ambiente seguro tanto para o discente quanto para os pacientes. Objetivo: Verificar a eficácia da aquisição de habilidades após o treinamento em simulador de alta fidelidade de cirurgia videolaparoscópica. Método: Pesquisa de abordagem qualitativa, descritiva e aplicada, realizada através da coleta de dados do questionário semiestruturado pela pesquisadora aplicado em residentes do Programa de Residência Médica em Cirurgia Geral da UFT (PRMCG-UFT) e entrevista oral gravada e depois transcrita com os preceptores cirurgiões. Resultados: Seguindo o critério de inclusão adotado nesta pesquisa, foram utilizados os relatos de sete residentes de cirurgia geral que, após o treinamento em simulador, concluíram adquirir habilidades em procedimentos videolaparoscópicos. Dois residentes mencionaram que tiveram dificuldades na execução das tarefas devido a alta sensibilidade exigida pelo simulador em alguns procedimentos. Somente um dos entrevistados apontou não ser didática a metodologia dos “Seis Passos”, utilizada durante treinamento no simulador, porém foi bem aceita pelos demais. Um dos residentes relatou a importância da presença de um tutor durante o uso do simulador. Os preceptores entrevistados relataram que as habilidades adquiridas pelos residentes após o treinamento no Lap VR foi transferida para a cirurgia videolaparoscópica em pacientes reais. Conclusão: Com o presente estudo pode-se concluir que, de acordo com a percepção técnica e críticas dos residentes e preceptores do PRMCG-UFT, o treinamento padronizado utilizando a metodologia dos “Seis Passos” utilizando o LapVR mostrou-se ser eficaz na aquisição de habilidades para posteriores procedimentos cirúrgicos, tanto em cirurgias abertas quanto nas videocirurgias em pacientes reais. / The long learning curve consumes too much time surgeons teachers because it requires strict monitoring and prolonged teaching residents. Innovations in education in health, together with technological advances, has resulted in increasingly sophisticated simulators, awakening thus best interests by simulation. The adoption of high-fidelity surgery simulator (Lap VR) in practical lessons with the resident in general surgery at the Federal University of Tocantins (UFT) is intended to foster learning of these students, and training in a safe environment for both students and for the patients. Objective: To determine the effectiveness of the acquisition of skills after training in high-fidelity laparoscopic surgery simulator. Method: Qualitative research, descriptive and applied, conducted by questionnaire data collection semi-structured by the researcher applied to residents of the Medical Residency Program in General UFT Surgery (PRMCG-UFT) and recorded oral interview and then transcribed with tutors surgeons. Results: Following the inclusion criteria adopted in this research, reports of seven general surgery residents were used, after the simulator training, concluded acquire skills in laparoscopic procedures. Two residents mentioned that they had difficulties in performing the tasks due to the high sensitivity required by the simulator in some procedures. Only one respondent pointed out the methodology of not teaching "Six Steps" used for training in the simulator, but it was well accepted by the others. One of the residents reported the importance of the presence of a tutor while using the simulator. Preceptors respondents reported that the skills acquired by residents after training on Lap VR moved to laparoscopic surgery on real patients. Conclusion: In this study it can be concluded that, in accordance with the technical insight and criticism from residents and preceptors of PRMCG-UFT, standardized training using the methodology of "Six Steps" using LapVR proved to be effective in acquisition skills for later surgical procedures in both open surgery and in the videocirurgias on real patients.
45

"Desenvolvimento de um Simulador de Treinamento para Operadores do Reator de Pesquisa IEA-R1" / DEVELOPMENT OF A TRAINING SIMULATOR TO OPERATORS OF THE IEA-R1 RESEARCH REACTOR

Ricardo Pinto de Carvalho 02 August 2006 (has links)
Este trabalho apresenta o desenvolvimento de um Simulador do Reator de Pesquisa IEAR1. O Simulador foi desenvolvido com Visual C++ em duas etapas: 1) construção dos modelos matemáticos e 2) criação e configuração de interfaces gráficas em um aplicativo Windows XP. Utilizou-se uma modelagem simplificada dos principais fenômenos físicos: o nuclear através de cinética pontual, e o modelo de térmica e hidráulica através das leis de conservação de massa e energia no canal médio do reator. As equações diferenciais dinâmicas dos processos nucleares, térmicos e hidráulicos foram solucionadas pela técnica de diferenças finitas através do método de Runge-Kutta de 4ª ordem. Foram modelados os sistemas: controle de reatividade, resfriamento do reator e proteção do reator. As variáveis de processo são armazenadas em arquivos ASCII. O Simulador permite o usuário navegar por interfaces gráficas dos sistemas e monitorar tendências dos transientes de operação sendo uma ferramenta interativa para ensino e treinamento de operadores do IEA-R1. Este também pode ser usado por alunos e professores no ensino de teoria de reatores, térmica e hidráulica. O Simulador permite simulações de operações de partida, manobra de potência e parada. / This work reports the development of a Simulator for the IEA-R1 Research Reactor. The Simulator was developed with Visual C++ in two stages: 1) construction of the mathematics models and 2) development and configuration of graphics interfaces in a Windows XP executable. A simplified modeling was used for main physics phenomena, using a point kinetics model for the nuclear process and the energy and mass conservation laws in the average channel of the reactor for the thermal hydraulic process. The dynamics differential equations were solved by using finite differences through the 4th order Runge- Kutta method. The reactivity control, reactor cooling, and reactor protection systems were also modeled. The process variables are stored in ASCII files. The Simulator allows navigating by screens of the systems and monitoring tendencies of the operational transients, being an interactive tool for teaching and training of IEA-R1 operators. It also can be used by students, professors, and researchers in teaching activities in reactor and thermal hydraulics theory. The Simulator allows simulations of operations of start up, power maneuver, and shut down.
46

Programa computacional para um simulador de vôo / A computer program for a flight simulator

Beluzo, Carlos Eduardo 27 April 2006 (has links)
Os simuladores de vôo têm sido uma importante ferramenta para treinamento de pilotos e análise de vôo sem ter que se desembolsar grandes quantias monetárias, economizando combustível e evitando acidentes. Conseqüentemente, a demanda por simuladores de vôo tem aumentado tanto na indústria quanto na pesquisa. Com o intuito de futuramente construir um simulador de vôo, foi desenvolvido um projeto para elaboração de um software capaz de simular uma aeronave em vôo, do ponto de vista de dinâmica de vôo. O software SIMAERO foi desenvolvido na linguagem de programação C++ e simula a dinâmica de vôo de uma aeronave. Esta simulação consiste em resolver as equações de movimento da aeronave, utilizando o modelo matemático de equações diferenciais ordinárias proposto por ETKIN & REID, et al (1996). O modelo matemático é solucionado através do método de integração numérica Runge-Kutta de 4ª ordem conforme apresentado em CONTE (1977). Como parâmetros de entrada são informadas as seguintes características da aeronave: dados geométricos, dados aerodinâmicos e derivadas de estabilidade. Os resultados das simulações são apresentados em gráficos cartesianos e gravados em arquivos. Os gráficos são úteis para que possa ser feita uma posterior análise do comportamento da aeronave. Os arquivos gravados com os resultados das simulações podem ser utilizados em alguma aplicação futura, como sinas de entrada para uma plataforma de simulação, por exemplo. Neste trabalho será descrito como o SIMAERO foi desenvolvido e ao final serão apresentados alguns resultados obtidos. / Flight simulators have been an important tool for pilots training and for flight analyses, without having to spend a high quantity of money, saving gas and prevent accidents. Because of this, the demand for flight simulators has increased both in industry and in research centers. With the objective of in future build a flight simulator, a project to develop a software that is able to simulate the dynamics of flight of a flying aircraft was developed. The SIMAERO software was developed using C++ and its principal functionality is to simulate the dynamics of flight of an aircraft. This simulation basically is the solution of the system of motion equations of the aircraft, using the mathematical model described by ETKIN & REID, et al (1996). The mathematical model is solved using the 4th order Runge-Kutta numeric integration method, as presented in CONTE (1977). For the simulation, the geometric data, the aerodynamic data, and the dimensional derivates are passed to the software as input arguments. The results of the simulations are displayed as cartesians graphics and recorded as data files. The graphics are useful for visual analyses of the aircraft behavior, and the file, with the results of the simulation, can be used as input data for ground based simulator, for example. In this work, the development of the software SIMAERO will be presented, and then some results of the simulation of one aircraft will be shown.
47

Desenvolvimento de simulador mamográfico para avaliação de esquemas CAD / Development of a breast Phantom for CAD schemes evaluation

Stemberg, Débora Regina Malvesi 19 May 2010 (has links)
Visando a um melhor desempenho na avaliação de imagens mamográficas, diversos trabalhos utilizando técnicas de processamento de imagem vêm sendo desenvolvidos como parte de esquemas computacionais que auxiliam o diagnóstico, denominados de esquemas CAD. Entretanto, um dos maiores desafios no desenvolvimento destes sistemas está relacionado com a avaliação de seu desempenho, que pode apresentar inconsistências, como impossibilidade de comparação dos resultados devido à dificuldade de se obter bancos de imagens amplos, comuns e confiáveis, que apresentem características de aquisição variadas atendendo aos requisitos específicos da técnica. Este trabalho tem por objetivo auxiliar nesse campo, apresentando um protótipo de simulador radiográfico de mama que possibilite gerar imagens que se assemelhem às de uma mamografia real através ainda de uma distribuição aleatória das estruturas de interesse simuladas. Isso permite a aquisição de um grande conjunto de imagens, por diferentes formas e condições, tornando possível testar e avaliar com maior precisão o desempenho de esquemas CAD destinados à mamografia. Tem a virtude de dispensar a validação dos resultados apontados pelo esquema com base no laudo do especialista, visto que é possível saber previamente quais são e quantas são as estruturas presentes em cada imagem, bem como a localização exata de cada uma delas. Portanto, torna-se possível assegurar com confiança a eficácia e viabilidade do esquema CAD testado, tanto em relação ao resultado apresentado pelo sistema quanto em relação à minimização de erros sistemáticos, dada a aleatoriedade da distribuição das estruturas-alvo da avaliação, como ocorre no exame real. / In order to obtain a better performance in the evaluation of mammographic images, several studies using image processing techniques have been developed as part of computer aided diagnosis, known as CAD systems. However, one of the main challenges in the development of such schemes is the performance evaluation, which may present problems, as such as difficulty in comparing results due to the inability to obtain large and common databases with wide-ranging characteristics of image acquisition. This work has the purpose of helping in this field, by presenting a breast phantom to allow obtaining images closer to those from actual mammography due to a random distribution of simulated interest structures. This provides to get a large images set, obtained from different conditions, and it allows to evaluate more accurately the performance of mammography CAD schemes. The use of this phantom has also the advantage of validating the scheme results without using the radiological report, since it provides the exact knowledge of the number and characteristics of the structures present in the image, as well as their positioning. Therefore, the efficacy and feasibility of a CAD scheme under test can be assured, regarding the results and also by the minimization of systematic errors due to the random distribution of the structures of clinical interest, similarly to the actual exam.
48

Desenvolvimento e aplicação de um simulador pediátrico craniano para dosimetria em tomografia computadorizada / Development and application of a pediatric head phantom for dosimetry in computed tomography

Martins, Elaine Wirney 10 May 2016 (has links)
Para avaliar os níveis de exposição e a dose absorvida em pacientes submetidos a exames de tomografia computadorizada, TC, é necessário calcular os índices de dose em medições com um simulador de PMMA, ou cheio de água. O simulador deve ser capaz de reproduzir as características de absorção e espalhamento do corpo ou parte do corpo humano em um campo de radiação. As grandezas específicas em TC: índice de kerma livre no ar (Ca,100), índice de kerma no ar ponderado (CW), índice de kerma no volume total (Cvol) e produto kerma no ar-comprimento (PKL) devem ser determinadas e comparadas com os níveis de referência já existentes na literatura. Neste trabalho foi desenvolvido um simulador pediátrico craniano, já que no Brasil os níveis de referência para diagnósticos (NRDs) disponíveis foram determinados baseados em um simulador padrão adulto. O simulador desenvolvido inovou em sua construção apresentando materiais que simulam a calota craniana em osso cortical (alumínio) e osso esponjoso (PVC). O seu interior foi preenchido com água destilada. As dimensões foram escolhidas de acordo com as recomendações da Organização Mundial da Saúde e do International Commission on Radiation Units, para o tamanho da cabeça de uma criança de 0 a 5 anos: 160 mm de diâmetro e 155 mm de altura. A calota craniana tem uma espessura de 4 mm e diâmetro interno de 111,9 mm. Para avaliar seu comportamento foram realizados testes em laboratórios e em feixes clínicos. Os resultados apresentaram uma atenuação de até 23% na utilização dos materiais que simulam a calota craniana evidenciando que os valores adotados para os cálculos de NRD podem estar superestimando a dose recebida por pacientes pediátricos. Percebe-se que a dose recebida em exames de crânio apresenta uma distribuição diferente por ser parcialmente atenuada e/ou retroespalhada pela calota craniana, o que não é considerado ao se utilizar o simulador constituído apenas de PMMA. / To determine the exposure levels and the absorbed dose in patients undergoing CT scans, is necessary to calculate the CT dose index in measurements with a PMMA or water phantom. The phantom must be enough to simulate the attenuation and scattering characteristics of a human body or parts in a radiation field. The CT specific quantities : CT air kerma index (Ca,100) , weighted CT air kerma index (CW ), a total volume CT air kerma index (Cvol) and the CT air kerma-lenght product (PKL) must be determined and compared to literature reference levels. In this work a head pediatric phantom was developed, considering that the Brazilian published Diagnostic Reference Levels (DRL) are based on adult phantom measurements. This developed phantom shows a construction innovation using materials to simulate the skullcap, cortical bone (aluminum) and cancellous bone (PVC), and it was filled with distilled water. The phantom dimension follows the recommendations of the World Health Organization and the International Commission on Radiation Units for children from 0 to 5 years old head size: diameter of 160 mm and height of 155 mm. The skullcap has 4 mm of thickness and 111.9 mm of internal diameter. In order to evaluate its behavior, tests were carried out in calibration laboratories and in clinical beams. The results showed attenuation up to 23% when different materials are used as skullcap, demonstrating that the DRLs adopted could be overestimating the dose received by pediatric patients. It is observed that the dose received by CT skull scans presents different distribution, due to the skullcap partially attenuation and/or backscattering which is not considered when the PMMA phantom is used.
49

Recursos tecnológicos e temas transversais no ensino da física: um estudo de caso no IFSul/Câmpus Camaquã

Barbosa, Leandro Neutzling 12 1900 (has links)
Submitted by FERNANDA DA SILVA VON PORSTER (fdsvporster@univates.br) on 2017-02-14T16:52:44Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) 2014LeandroNeutzlingBarbosa.pdf: 3337433 bytes, checksum: 33f7f5d94a338d2265d419aded2840c5 (MD5) / Approved for entry into archive by Ana Paula Lisboa Monteiro (monteiro@univates.br) on 2017-03-29T19:27:01Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) 2014LeandroNeutzlingBarbosa.pdf: 3337433 bytes, checksum: 33f7f5d94a338d2265d419aded2840c5 (MD5) / Made available in DSpace on 2017-03-29T19:27:01Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) 2014LeandroNeutzlingBarbosa.pdf: 3337433 bytes, checksum: 33f7f5d94a338d2265d419aded2840c5 (MD5) Previous issue date: 2017-02 / Salienta-se que o computador e o software educacional podem ser ferramentas nos processos de ensino e aprendizagem. Diante disso, a presente pesquisa visa analisar as potencialidades dos simuladores computacionais nos processos de ensino e aprendizagem através de uma abordagem transversal sobre o tema Efeito Estufa. A atividade foi desenvolvida com uma turma de estudantes do 2º ano do Curso Técnico em Automação Industrial- Forma Integrada, na disciplina de Física II do Instituto Federal de Educação, Ciência e Tecnologia Sul-rio-grandense (IFSul)/Câmpus Camaquã. A proposta adotou por base os pressupostos de uma pesquisa qualitativa com viés exploratório e delineamento metodológico de um estudo de caso. Os resultados foram discutidos a luz da teoria da aprendizagem significativa de Ausubel. É possível destacar que houve indícios de uma evolução significativa no conhecimento dos estudantes sobre o tema abordado. Dessa maneira, pode-se concluir que o simulador PhET tem potencial para auxiliar no processo de ensino e aprendizagem. / It stands out that computers and educational software may be tools for the teaching and learning processes. Therefore, this research aims to analyze the potentials of computer simulators in the teaching and learning processes through a transversal approach on the theme of Glasshouse Effect. The activity was developed with a class of students from the 2nd year of the Industrial Automation Technical Course – Integrated form, for the subject of Physics II at the Federal Institute for Education, Science and Technology in Rio Grande do Sul IFSul/Camaquã Câmpus. The proposal adopted as a basis the presumptions of a qualitative research with exploratory bias and methodological outlining of a case study. The results are discussed in the light of Ausubel’s meaningful learning theory. It is possible to highlight that there was possible to identify evidence of significant evolution in students’ knowledge of the theme covered. Thus, it can be assumed that the PhET simulator has potential to aid in the teaching and learning process.
50

Avaliações de qualidade aplicadas na comparação de sistemas mamográficos digitais e convencionais / Quality assessment applied to the comparison as digital and conventional mammographics systems

Luís Carlos Hamula Campos 29 April 2008 (has links)
Este trabalho tem por objetivo avaliar o desempenho dos equipamentos de radilogia digital, especificamente, mamógrafo de campo total e mamógrafos convencionais no que se refere à detecção de sinais e em termos da geometria da exposição. O trabalho se desenvolve a partir da formação de um conjunto de imagens mamográficas do simulador ACR modelo 156; este conjunto é composto por imagens mamográficas de equipamentos convencionais e digitais de campo total e imagens obtidas por um simulador radiográfico incorporado a um pacote computacional que fornece informações características de equipamentos radiológicos quanto ao desempenho do sistema em termos da geometria de exposição como ponto focal, limites de resolução e ruído aleatório produzido. A partir dos resultados das interpretações das imagens do simulador ACR pelos observadores, determina-se o índice de acertos; paralelamente analisam-se os dados relativos à geometria da exposição. / This work is aimed at evaluating the performance of digital radiology especially full digital mammograph and conventional mammograph in order to detect signals send in terms of geometry of the exposition. The work is developed from the formation of a pool of mammographic images of the ACR Phantom 156; this bank is formed by mammograph images of both conventional and full field digital equipments and images got by a radiographic test gadget linked to a software package that provides typical information of radiologic equipments concerning the system\'s performance regarding geometric of exposition like focal spot, margins of resolution and aleatory noise. From the results of the interpretation of the ACR simulator\'s images by the observers, then, we are able to determine what is right, at the same time to analyze the data related to the geometry of exposition.

Page generated in 0.0446 seconds