• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 3
  • Tagged with
  • 6
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de processo termico otimizado para mosto de caldo de cana na fermentação alcoolica / Development of thermal process otmized for mosto sugar canes in alcoholic fermentation

Nolasco Junior, Jonas 23 February 2005 (has links)
Orientador: Pilar Rodriguez de Massaguer / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-04T02:36:41Z (GMT). No. of bitstreams: 1 NolascoJunior_Jonas_M.pdf: 917952 bytes, checksum: 1c082a25920f5c8390a73425551d86ef (MD5) Previous issue date: 2005 / Resumo: Nesta pesquisa é proposto um processo de tratamento térmico do mosto, com máxima preservação do conteúdo em açúcares fermentescíveis (sacarose, glicose e frutose), a fim de promover a inativação térmica de seus contaminantes bacterianos e por extensão os da fermentação alcoólica. Com esse objetivo foram examinadas as cinéticas de degradação térmica da sacarose, glicose, frutose e açúcares redutores totais (ART) (110 ¿ 140ºC) e também dos esporos de B. stearothermophilus (98 ¿ 130ºC), esporulado termo-resistente contaminante típico de mosto. Todos os fatores termodegradáveis estudados apresentaram cinéticas de destruição térmicas não-lineares de forma que o índice de redução decimal (D), obtido por regressão linear, não foi representativo da velocidade de inativação térmica, e assim as cinéticas foram analisadas mediante modelos não lineares que permitiram obter as constantes de velocidade de inativação (k). Seguidamente utilizando um gráfico tipo Arrhenius a energia de ativação Ea foi determinada e o valor de z foi obtido. As curvas de sacarose remanescentes obtidas durante estudo da sua hidrólise térmica, foram ajustadas por modelos logísticos que se mostraram apropriados para descrever ombros planos e caudas finais nas curvas cinéticas. A energia de ativação e valor z obtidos foram 112,32 kJ/mol e 26,99ºC, respectivamente. Essa reação se mostrou praticamente equimolecular quanto às hexoses produzidas. As curvas de concentração de ART vs tempo remanescentes foram ajustadas por modelos logísticos bipopulacionais, apropriados em casos em que o processo global é descrito por duas frações de compostos, as hexoses glicose e frutose, que se degradam em velocidades diferentes e apresentam ombros e caudas. Os valores de energia de ativação obtidos para a frutose e glicose foram bem próximas: 140,37 kJ/mol e 140,23 kJ/mol, respectivamente. Os valores z obtidos foram 21,59ºC e 21,61ºC. Quanto às velocidades de degradação a frutose apresentou velocidade 9 vezes maior do que a da glicose. A suspensão de esporos se mostrou heterogênea em resistência. A temperatura influenciou a forma das curvas de sobreviventes, para os esporos de B. stearothermophilus ATCC1518. Nas temperaturas mais baixas, as curvas de inativação térmica apresentaram ombro plano, passando por comportamento de modelos de frações lineares consecutivas, e finalmente na temperatura mais elevada apresentou modelo linear com eliminação da fração termo-sensível. Os valores de energia de ativação e z obtidos foram 249,52 kJ/mol e 11,48ºC, respectivamente. O processo térmico para inativação dos contaminantes do mosto foi definido após o decantador, onde foram quantificados grandes grupos microbianos em amostras coletadas de Usinas situadas em regiões de clima e umidade distintas. A concentração máxima de esporos termofílicos produtores de acidez plana foi de 9x101esporos/ml de mosto em Usina localizada em região quente e úmida enquanto um valor de 4 esporos/ml de mosto foi encontrado em Usina localizada em região de clima seco e com predominância de solo com baixa capacidade de retenção de água. Foi determinada a letalidade do processo de decantação para os contaminantes do caldo de cana e mosto através da determinação da história térmica mínima detectada no ponto mais frio de dois decantadores industriais. Baseado no tempo de residência médio e na temperatura mais fria detectada foi possível estimar que a decantação produz, em média, 4,0 x 106 reduções decimais da população de Lactobacillus fermentum e apenas 0,14 reduções decimais nos esporos de B. stearothermophilus. Baseado no conhecimento da cinética dos principais fatores termodegradáveis foi definida uma região de tratamento térmico que se extende dos 114 a 140ºC e de 3000 a 4 segundos. Graficamente essa região é um triangulo delimitado, abaixo pela reta correspondente a 5 reduções decimais dos esporos de B. stearothermophilus e acima pela reta correspondente à preservação de 98,7% dos ART do mosto. O nível de preservação de 98,7% dos ART foi escolhido pela precisão das análises usadas na determinação dos mesmos (1,3%). Qualquer processo térmico dentro dessa região será capaz de satisfazer o requisito de 5 reduções decimais dos esporos de B. stearothermophilus e preservação de 98,7% dos ART do mosto. A prática desse processo térmico implica na adoção de uma estratégia preventiva no controle da contaminação da fermentação em oposição às estratégias corretivas baseadas no uso de antibióticos que se pratica nas Usinas de Açúcar e Álcool Brasileiras / Abstract: In this research is proposed a thermal treatment process for sugar cane must with maximum retention of fermentable sugar (sucrose, glucose and fructose), to promote a thermal inactivation of its bacterial contaminants and therefore, those of alcoholic fermentation. With this objective were examined the thermo degradation kinetics of sucrose, glucose, fructose, total reducing sugars (TRS) (110 ¿ 140ºC) and also B. stearothermophilus spores (98 ¿ 130ºC), a typical thermo resistant sporulated contaminant of musts. All thermo degradable factors showed non-linear thermal destruction kinetics due to this the D value, obtained for linear regression, could not be used, thus the kinetics were reported by Arrhenius model, obtaining the reaction rates (k), Activation Energy (Ea) and the z value through out Ea values. Sucrose remaining curves obtained as a function of time during its thermal hydrolysis, were fitted by logistic models which are suitable to describe flat shoulders and ending tales in the kinetic curves. Activation Energy and z value were 112,32 kJ/mol and 26,99°C, respectively. This reaction showed to be equimolecular in regard to the produced hexoses. TRS remaining curves vs time were adjusted by logistic bipopulational models, suitable when the overall process presents two fractions, the hexoses glucose and fructose, with different degradation rates with shoulders and tales. Ea and z values for fructose and glucose were quite close: 140,37 kJ/mol, z of 21,59°C and 140,23 kJ/mol, z of 21,61°C, respectively. As far as degradation rates are concerned, fructose showed to degrade 9 times faster than glucose. Spores suspension showed heterogeneity in thermal resistance. Temperature affected the shape of survival curves for B. stearothermophilus ATCC1518 spores. At lower temperatures, it showed flat shoulder, passing through consecutive linear fraction models behaviors, and finally at higher temperatures followed linear model with elimination of the thermo-sensible fraction. Ea and z values were 249,52 kJ/mol and 11,48°C respectively. A thermal process for sugar cane must contaminant inactivation was defined after the decanter, where microbiological quantification of various microbial groups was carried out on samples from sugar cane mills located in region with different climate and humidity conditions. The maximum thermophilic flat-sour spores count was of 9 x 101 spores/ml of must and was originated from a sugar cane mill located at the warmest and most humid region, while a count of 4 spores/ml of must was found in a plant with dry climate and with soil of low capability for water retention. Decanters lethality of must contaminant was determined based on the minimum detected thermal history in two industrial equipments. Applying the average residence time with this thermal history, it was estimated that the decantation results, on average, 4,02*106 log reductions of Lactobacillus fermentum and only 0,13 log reductions in the counting of B. stearothermophilus spores. Based on the kinetic knowledge of the thermo degradable major factors it was established a thermal process region from 114 to 140C and 3000 to 4 seconds. Graphically, this region is a triangle delimited by the line for 5 log reductions of B. stearothermophilus (lower limit), and the line for 98,7% retention of the must TRS. This preservation level was adopted considering the accuracy of the sugar analysis methodology (1,3%). Any thermal process within this region will be able to satisfy the requirement of 5 log reductions for B. stearothermophilus and 98,7% retention of must TRS. The implementation of this thermal process implies in the adoption of a preventive strategy in the contamination control of the fermenting process, opposite to the corrective strategies currently applied based on antibiotics, which is common practice in Brazilian Sugar Canes mills / Mestrado / Ciência de Alimentos / Mestre em Ciência de Alimentos
2

Développement et utilisation de sources de plasma pour stériliser des instruments médicaux

Pollak, Jérôme January 2009 (has links)
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal.
3

Faire et défaire la virilité. Les stérilisations masculines volontaires en Europe dans l'entre-deux guerres. / Doing and undoing Manliness. Voluntary male Sterilizations in Europe in the Interwar Period

Serna, Elodie 25 May 2018 (has links)
Depuis l’exploration naissante de l’économie endocrine du masculin jusqu’aux opérations de revitalisation pratiquées dans les années 1920 et 1930, cette thèse montre de quelle manière diverses opérations génitales, dont la vasectomie, participent des stratégies médicales de construction du masculin. En parallèle, la stérilisation masculine volontaire est explorée dans le cadre de projets eugénistes à partir d’une campagne pour la légalisation de la stérilisation en Grande-Bretagne, de débats au sein de la Ligue mondiale pour la réforme sexuelle et du mouvement néo-malthusien français. L’évolution des normes de masculinité et de paternité est enfin questionnée par le recours à la vasectomie comme moyen contraceptif de convenance. L’organisation de vasectomies clandestines, la répression et la réprobation sociale qu’elles suscitent interrogent la disposition de soi du côté des hommes et le rôle normatif de! la procréation. Le caractère polysémique des stérilisations permet ainsi d’explorer globalement les reconfigurations de la masculinité à une échelle transnationale. / From the nascent exploration of the endocrine system of the male to the revitalization operations performed in the 1920s and 1930s, this thesis shows how various genital operations, including vasectomy, contribute to medical strategies for the construction of masculinity. In parallel, voluntary male sterilization is explored in the context of eugenicist projects on the basis of a campaign for legalizing sterilization in Great Britain, the debates within the World League for Sexual Reform and the french neo-malthusian movement. The evolution of the norms of masculinity and paternity is finally questioned by the use of vasectomy as a convenient contraceptive method. The organization of clandestine vasectomies, the repression and social disapproval they generate question men's self-determination and the normative role of procreation. The polysemous nature of sterilizations thus makes possible the overall exploration of the reconfigurations of masculinit! y on a transnational scale.
4

Développement et utilisation de sources de plasma pour stériliser des instruments médicaux

Pollak, Jérôme January 2009 (has links)
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal
5

Protocolo de verificação do processo de esterilização por vapor de formaldeído / Verification protocol of the formaldehyde steam sterilization process

Borini, Júlio Cesar 08 December 2016 (has links)
Este trabalho apresenta o estudo do processo de esterilização de materiais e instrumentais cirúrgicos em autoclaves que se utilizam do agente esterilizante, o vapor à baixa temperatura de formaldeído. Processo esse utilizado para materiais termosensiveis, ou seja, que não suportam temperaturas superiores a 80°C. Assim objetivo desse trabalho, foi avaliar essa tecnologia de esterilização a baixa temperatura, que já é utilizada há mais de 20 anos em vários países, inclusive aqui no Brasil, porém com pouco detalhes de estudos conclusivos sobre o assunto na literatura nacional e internacional. Este estudo foi baseado nas Normas ABNT NBR 15659 e NF EN ISO 25424 que tratam especificamente dos requisitos, métodos e cuidados na esterilização de vapor a baixa temperatura e formaldeído, implementando um protocolo de verificação para estudo da tecnologia. Para tanto foi elaborada uma metodologia de avaliação, da instalação de esterilizadores que utilizam como agente esterilizante o formaldeído. Na verificação da eficácia da metodologia 3 tipos de equipamentos de esterilização foram testados. Os equipamentos testados são de fabricação brasileira (02 deles) e um de fabricação sueca. Os testes foram feitos em 6 hospitais, onde foram avaliados desde a sua instalação, avaliação dos parâmetros de tempo, temperatura e pressão (com equipamentos calibrados e rastreados pelo INMETRO), avaliação do nível de resíduos no material (com laudos feitos por laboratórios credenciados), uso de indicadores de processo (biológicos e químicos), avaliação ambiental (ar e saída do dejeto para o esgoto), controles de manutenções preventivas e segurança do operador (EPI). Todos os ciclos avaliados apresentaram resultados dentro dos parâmetros mínimos sugerido na Norma ABNT NBR 15659 e NF EN ISO 25424. Concluindo que se seguindo rigorosamente o que pede a Norma e os manuais dos fabricantes dos equipamentos, pode-se perfeitamente obter um processo seguro de esterilização para o Hospital, e atender todos os níveis de segurança tanto para o operador como para o paciente que irá usar o material processado no ciclo de esterilização. / This work presents the study of the sterilization process of surgical materials and instruments in autoclaves using the sterilizing agent, the low temperature vapor of formaldehyde. This process is used for thermosensitive materials, is they do not withstand temperatures above 80 ° C. The objective of this study was to evaluate the low temperature sterilization technology, which has been used for more than 20 years in several countries, including here in Brazil, but with little details of conclusive studies on the subject in the national and international literature. This study was based on the ABNT NBR 15659 and NF EN ISO 25424 standards that specifically deal with the requirements, methods and care in low temperature steam sterilization and formaldehyde, implementing a verification protocol for technology study. For this, an evaluation methodology was elaborated for the installation of sterilizers that use formaldehyde as the sterilizing agent. In the verification of the effectiveness of the methodology 3 types of sterilization equipment were tested. The equipment tested is of Brazilian manufacture (02 of them) and one of Swedish manufacture. The tests were carried out in 6 hospitals, where they were evaluated since its installation, evaluation of parameters of time, temperature and pressure (with equipment calibrated and tracked by INMETRO), evaluation of the level of residues in the material (with reports made by accredited laboratories), use of process indicators (biological and chemical), environmental assessment (air and exits to the sewage), preventive maintenance controls and operator safety (EPI). All the evaluated cycles presented results within the minimum parameters suggested in the Standard ABNT NBR 15659 and NF EN ISO 25424. Concluding that strictly following the norms and the manuals of the equipment manufacturers, it is perfectly possible to obtain a safe process of sterilization To the Hospital, and meet all levels of safety for both the operator and the patient who will use the material processed in the sterilization cycle.
6

Protocolo de verificação do processo de esterilização por vapor de formaldeído / Verification protocol of the formaldehyde steam sterilization process

Borini, Júlio Cesar 08 December 2016 (has links)
Este trabalho apresenta o estudo do processo de esterilização de materiais e instrumentais cirúrgicos em autoclaves que se utilizam do agente esterilizante, o vapor à baixa temperatura de formaldeído. Processo esse utilizado para materiais termosensiveis, ou seja, que não suportam temperaturas superiores a 80°C. Assim objetivo desse trabalho, foi avaliar essa tecnologia de esterilização a baixa temperatura, que já é utilizada há mais de 20 anos em vários países, inclusive aqui no Brasil, porém com pouco detalhes de estudos conclusivos sobre o assunto na literatura nacional e internacional. Este estudo foi baseado nas Normas ABNT NBR 15659 e NF EN ISO 25424 que tratam especificamente dos requisitos, métodos e cuidados na esterilização de vapor a baixa temperatura e formaldeído, implementando um protocolo de verificação para estudo da tecnologia. Para tanto foi elaborada uma metodologia de avaliação, da instalação de esterilizadores que utilizam como agente esterilizante o formaldeído. Na verificação da eficácia da metodologia 3 tipos de equipamentos de esterilização foram testados. Os equipamentos testados são de fabricação brasileira (02 deles) e um de fabricação sueca. Os testes foram feitos em 6 hospitais, onde foram avaliados desde a sua instalação, avaliação dos parâmetros de tempo, temperatura e pressão (com equipamentos calibrados e rastreados pelo INMETRO), avaliação do nível de resíduos no material (com laudos feitos por laboratórios credenciados), uso de indicadores de processo (biológicos e químicos), avaliação ambiental (ar e saída do dejeto para o esgoto), controles de manutenções preventivas e segurança do operador (EPI). Todos os ciclos avaliados apresentaram resultados dentro dos parâmetros mínimos sugerido na Norma ABNT NBR 15659 e NF EN ISO 25424. Concluindo que se seguindo rigorosamente o que pede a Norma e os manuais dos fabricantes dos equipamentos, pode-se perfeitamente obter um processo seguro de esterilização para o Hospital, e atender todos os níveis de segurança tanto para o operador como para o paciente que irá usar o material processado no ciclo de esterilização. / This work presents the study of the sterilization process of surgical materials and instruments in autoclaves using the sterilizing agent, the low temperature vapor of formaldehyde. This process is used for thermosensitive materials, is they do not withstand temperatures above 80 ° C. The objective of this study was to evaluate the low temperature sterilization technology, which has been used for more than 20 years in several countries, including here in Brazil, but with little details of conclusive studies on the subject in the national and international literature. This study was based on the ABNT NBR 15659 and NF EN ISO 25424 standards that specifically deal with the requirements, methods and care in low temperature steam sterilization and formaldehyde, implementing a verification protocol for technology study. For this, an evaluation methodology was elaborated for the installation of sterilizers that use formaldehyde as the sterilizing agent. In the verification of the effectiveness of the methodology 3 types of sterilization equipment were tested. The equipment tested is of Brazilian manufacture (02 of them) and one of Swedish manufacture. The tests were carried out in 6 hospitals, where they were evaluated since its installation, evaluation of parameters of time, temperature and pressure (with equipment calibrated and tracked by INMETRO), evaluation of the level of residues in the material (with reports made by accredited laboratories), use of process indicators (biological and chemical), environmental assessment (air and exits to the sewage), preventive maintenance controls and operator safety (EPI). All the evaluated cycles presented results within the minimum parameters suggested in the Standard ABNT NBR 15659 and NF EN ISO 25424. Concluding that strictly following the norms and the manuals of the equipment manufacturers, it is perfectly possible to obtain a safe process of sterilization To the Hospital, and meet all levels of safety for both the operator and the patient who will use the material processed in the sterilization cycle.

Page generated in 0.1344 seconds