• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 243
  • 17
  • 8
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 271
  • 165
  • 98
  • 77
  • 55
  • 39
  • 37
  • 36
  • 29
  • 28
  • 27
  • 25
  • 23
  • 22
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Seleção de linhagens F5 de tomateiro em dois sistemas de cultivo sob temperaturas elevadas / Selecting lines F5 tomato in two cropping systems at elevated temperatures

SANTOS, Lucas da Silva 20 February 2012 (has links)
Submitted by (ana.araujo@ufrpe.br) on 2017-02-20T16:17:19Z No. of bitstreams: 1 Lucas da Silva Santos.pdf: 797064 bytes, checksum: c0db6a54d580614585740db051e28ad9 (MD5) / Made available in DSpace on 2017-02-20T16:17:19Z (GMT). No. of bitstreams: 1 Lucas da Silva Santos.pdf: 797064 bytes, checksum: c0db6a54d580614585740db051e28ad9 (MD5) Previous issue date: 2012-02-20 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Adverse environmental conditions, particularly high temperatures in tomato cause lower fertilization of the flowers, reducing fruit set and consequently the productivity. The ideal temperature for a better development and fruiting plant is 25 to 28ºC during the day and 15 to 18ºC overnight, outside these limits, the plant has trouble setting fruit. Thus, the aim of this work was to select F5 lines of tomato high temperature tolerance and genetic stability and adaptability in two culture environments. We evaluated 20 lines F5, and two controls Yoshimatsu and hybrid SE 1055 F1. The maximum mean temperature during the experiment inside the greenhouse and in the field were 37.46ºC and 32.55ºC, respectively, considered out of range to the ideal development of tomato, especially in the greenhouse, where the average maximum temperature was far above the ideal. Lines 08, 12 and 13 showed the highest percentage of fruit in a greenhouse, however in the field, there was no difference between lines. In field experiment, the cultivar Yoshimatsu and lines 06 and 08, showed average mass commercial fruit per plant more than 4.0 kg. Lines 06 and 08 showed high adaptability and stability and productivity for mass marketable fruits per plant, in the two environments, and for purposes of selection, the most suitable. / As condições ambientais adversas, principalmente temperaturas elevadas ao qual o tomateiro é submetido, provocam menor fertilização das flores, diminuindo o pegamento dos frutos e consequentemente a produtividade. A temperatura ideal para o melhor desenvolvimento e frutificação da planta é de 25 a 28ºC durante o dia e 15 a 18ºC durante a noite, fora desses limites, a planta passa a ter problemas na fixação de frutos. Desse modo, objetivou-se com esse trabalho selecionar linhagens F5 de tomateiro quanto à tolerância a altas temperaturas e a adaptabilidade e estabilidade genética em dois ambientes de cultivo. Foram avaliadas 20 linhagens F5, e como testemunhas a cultivar Yoshimatsu e o híbrido SE 1055 F1. Os valores médios da temperatura máxima durante o período do experimento no interior da casa de vegetação e no campo foram de 37,46ºC e 32,55ºC, respectivamente, considerados fora dos limites ideais ao desenvolvimento do tomateiro, principalmente em casa de vegetação, onde a média da temperatura máxima ficou muito acima da ideal. As linhagens 08, 12 e 13 apresentaram maior porcentagem de pegamento de frutos na casa de vegetação, já no campo, não houve diferença entre as linhagens. As linhagens 06 e 08 e a cultivar Yoshimatsu, no experimento de campo, apresentaram média de massa comercial de frutos por planta superior a 4,0 kg. As linhagens 06 e 08 apresentaram maior adaptabilidade e estabilidade e produtividade para massa de frutos comerciais por planta, aos dois ambientes, sendo, para efeito de seleção, as mais indicadas.
162

Estudo de estruturas de concreto sob altas temperaturas através do método dos elementos finitos / Study of concrete structures under high temperature using the finite element method

Lemos, Paulo Sérgio Baumbach January 2011 (has links)
Tradicionalmente, admite-se que o concreto é um material resistente ao fogo por ser incombustível e apresentar baixa condutividade térmica (elevada capacidade de isolamento térmico). No entanto, quando exposto a altas temperaturas, experimenta vários problemas: a deterioração das propriedades térmicas e mecânicas, o dano causado pela restrição às deformações térmicas e a possibilidade de ocorrência de desplacamentos. Neste contexto, as modelagens computacionais, especialmente através do método dos elementos finitos, têm adquirido cada vez mais importância. Através da simulação do comportamento das estruturas de concreto sob altas temperaturas um dado problema pode ser estudado em diferentes cenários, geometrias, propriedades dos materiais, carregamentos e condições de vinculação. Neste trabalho foi desenvolvido um programa computacional para a simulação do comportamento termomecânico não linear de estruturas planas de concreto armado sob a ação de altas temperaturas através do método dos elementos finitos. O programa realiza, em sequência, para cada incremento de tempo, as análises térmica e mecânica. O campo de temperaturas, determinado na análise térmica, é considerado na determinação das propriedades dos materiais, consideradas na análise mecânica. Na análise mecânica, utilizou-se o modelo de fissuras discretas para a representação do comportamento frágil do concreto sob a ação dos esforços de tração. O modelo de armadura incorporada foi empregado para a representação mecânica da armadura. Foi desenvolvida uma analogia térmica ao modelo mecânico de armadura incorporada para a consideração da contribuição do aço na transferência de calor. Os resultados do programa foram comparados com valores experimentais disponíveis na literatura. Primeiramente, realizou-se a análise térmica de seções de concreto de diferentes formas. Após, foi analisado o comportamento termomecânico de uma laje armada em uma só direção. As respostas obtidas tiveram boa aproximação em todas as comparações executadas. / Traditionally, it is admitted that concrete is a fire-resistant material due to its incombustible nature and low thermal conductivity (high insulating capacity). However, when exposed to high temperatures, it experiments a number of problems: deterioration of its thermomechanical properties; damage caused by the restricted thermal deformations; and the possibility of spalling. In this context, computational modelings, especially through the Finite Element Method, have gained increasing importance. Through the simulation of the behavior of concrete structures under high temperatures, a given problem can be studied in different scenarios, geometries, material properties, loadings, and boundary conditions. In this work a computational program for the simulation of non-linear thermo-mechanical behavior of reinforced concrete plane structures under the action of high temperatures through the Finite Element Method was developed. The program executes, in a sequence, for each time increment, thermal and mechanical analyses. The temperature field, determined in the thermal analysis, is considered in the determination of the material properties that are considered in the mechanical analysis. In the mechanical analysis, the smeared cracking model to represent the fragile behavior of concrete under the action of tension stresses was used. The embedded model was used in the mechanical representation of the reinforcement. A thermal analogy of the mechanical embedded model for reinforcement bars to the steel contribution in the heat transfer was developed. The program results were compared with experimental values available in the literature. Firstly, a thermal analysis of the concrete sections was carried out in different ways. Next, the thermo-mechanical behavior of a one-way reinforced slab was analyzed. The obtained responses had a close agreement in all comparisons conducted.
163

[en] RESIDUAL STRENGTH OF REINFORCED CONCRETE COLUMNS SUBJECT TO ELEVATED TEMPERATURES / [pt] RESISTÊNCIA RESIDUAL DE COLUNAS DE CONCRETO ARMADO SUBMETIDAS A ALTAS TEMPERATURAS

EDUARDO HENRIQUE DE BARROS LIMA 11 February 2019 (has links)
[pt] O concreto é conhecido por ter um bom desempenho quando exposto a altas temperaturas pelo fato de apresentar baixa condutividade térmica, ser incombustível e não exalar gases tóxicos. Entretanto, devido à sua composição heterogênea, o concreto sofre alterações físicas, químicas e mecânicas que podem comprometer sua integridade estrutural. Em estruturas de concreto armado, deve-se ter atenção especial aos pilares, cuja capacidade portante é reduzida significativamente em altas temperaturas e seu colapso, de natureza brusca, pode resultar na instabilidade global da estrutura. As reduções nas propriedades mecânicas dos materiais aliadas a lascamentos, fissuras e deformações excessivas podem comprometer seu desempenho, tornando-se necessária a verificação da segurança em situações de incêndio. Com o objetivo de analisar a resistência residual de colunas de concreto armado submetidas a altas temperaturas, foram realizados ensaios de compressão em corpos-de-prova cilíndricos de concreto simples de 5x10 cm submetidos a diferentes temperaturas (200, 400, 600, 800 e 1000 graus Celsius) e de concreto armado de 15x30 cm com diferentes configurações de estribos e submetidos a distintos tempos de exposição (30, 60, 90 e 120 minutos). Em ambos os ensaios, os corpos-de-prova foram resfriados em temperatura ambiente. Os resultados do programa experimental comprovam a perda de resistência à compressão e seus valores foram comparados a modelos numéricos e ao Método da Isoterma de 500 graus Celsius constante na ABNT NBR 15200 de 2004 e no EUROCODE 2. / [en] Concrete is well-known for exhibiting good performance when exposed to elevated temperatures because its low thermal conductivity coefficient, noncombustible properties and reduced emission of toxic gases. However, due to its heterogeneous composition, concrete undergoes physical, chemical and mechanical alterations that can compromise its structural integrity. In reinforced concrete structures, special attention should be paid to the columns, in bearing capacity is reduced significantly at elevated temperatures and their collapse, naturally brittle, may result in overall instability of structure. Reductions in the mechanical properties of the steel and concrete combined with spalling, cracking and excessive deformation compromise its performance, making it necessary to verify the safety in fire situations. In order to analyze the residual strength of reinforced concrete columns submitted to elevated temperatures, compression tests were carried out on plain concrete cylindrical specimens of 5x10 cm exposed to different temperatures (200, 400, 600, 800 and 1000 degrees Celsius) and on reinforced concrete of 15x30 cm considering different stirrups configuration and exposure times (30, 60, 90 and 120 minutes). In both tests, the specimens were cooled to room temperature. The results of the experimental program demonstrate the loss of compression strength and their values were compared to those obtained numerical models and to the Isotherm Method of 500 degrees Celsius, recommended in ABNT NBR 15200 of 2004 and in EUROCODE 2.
164

Criterios de diseño en puentes de hormigón frente a la acción térmica ambiental

Mirambell Arrizabalaga, Enrique 06 March 1987 (has links)
El presente trabajo centra su estudio en la problemática de los efectos térmicos ambientales en puentes de hormigón. Los objetivos perseguidos en esta tesis son, por una parte, el desarrollo de un modelo analítico capaz de obtener la respuesta térmica y tensional a nivel sección de los tableros de puentes de hormigón y el estudio de la influencia de todos los parámetros que intervienen en el fenómeno de la transmisión del calor en esta tipología estructural. Por otra parte, se presenta una metodología general de obtención de las acciones térmicas y los estados tensionales asociados, a considerar en el proceso de análisis y diseño de los puentes de hormigón. Dicha metodología ha sido aplicada, con posterioridad, al caso de puentes de hormigón emplazados en la geografía de nuestro país, siendo las bases de datos los resultados de los amplios estudios paramétricos llevados a cabo para cada una de las tipologías transversales de tablero comúnmente adoptadas en proyecto, y la información climatológica y ambiental recogida en las publicaciones del Instituto Nacional de Meteorología. / The present work is based on the problem of environmental thermal effects on concrete bridges. In this study, an analytical model is developed to determine the time-dependent temperature distributions and the self-equilibrated longitudinal and transversal stresses distributions within the cross section of concrete bridges. Parametric studies are carried out in order to find the effects of all parameters governing the heat transfer and conduction problem. Moreover, a general methodology in order to obtain design stresses distributions and design thermal loads is presented. Such methodology is applied to the case of concrete bridges in Spain. Data bases are the results of parametric studies and the environmental information presented in several reports of National Institute of Meteorology.
165

Influ?ncia de tratamentos t?rmicos de recozimento na microestrutura de uma liga NiTi pseudopl?stica

Viana, Thiago Souza 30 June 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-12-01T23:25:13Z No. of bitstreams: 1 ThiagoSouzaViana_DISSERT.pdf: 4828616 bytes, checksum: ee06ed8ff3676ebb8c30b440a888b38d (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-12-05T20:32:59Z (GMT) No. of bitstreams: 1 ThiagoSouzaViana_DISSERT.pdf: 4828616 bytes, checksum: ee06ed8ff3676ebb8c30b440a888b38d (MD5) / Made available in DSpace on 2017-12-05T20:32:59Z (GMT). No. of bitstreams: 1 ThiagoSouzaViana_DISSERT.pdf: 4828616 bytes, checksum: ee06ed8ff3676ebb8c30b440a888b38d (MD5) Previous issue date: 2017-06-30 / No presente trabalho, estudou-se a influ?ncia de tratamentos t?rmicos nas transforma??es microestruturais de uma liga NiTi com mem?ria de forma de composi??o qu?mica aproximadamente equiat?mica. Um fio de NiTi com 2,5 mm de di?metro, recebido no estado encruado, foi submetido a tratamentos t?rmicos de recozimento em temperaturas de 450 ?C e 500 ?C para observa??o das varia??es microestruturais. As microestruturas predominantes antes e ap?s o recozimento foram observadas, registrando-se um aumento na granulometria da martensita tanto com a temperatura como com a dura??o do tratamento t?rmico entre 30? e 3hs. Foram determinadas as temperaturas de transforma??o, (As, Af, Ms, Mf) de cada amostra, e as altera??es nas temperaturas de transforma??o entre o material no estado encruado e ap?s recozimento. Medidas de microdureza n?o revelaram influ?ncia significativa de tratamentos t?rmicos de recozimento e tampouco de resfriamentos a temperaturas subzero. / In the present work, the influence of heat treatments on the microstructural transformations of an approximately equiatomic NiTi memory form alloy was investigated. A NiTi wire with 2.5 mm in diameter, received in the work hardened state, was submitted to annealing heat treatments at 450 ?C and 500 ?C in order to verify the calorimetric and microstructural changes. The microstructure in the work hardened condition and after the annealing heat treatments was analyzed, which showed a coarsening of the martensite plates for higher temperatures and longer heat treatment times. The determination of the transition temperatures (As, Af, Ms, Mf) and the change in the transformation temperatures between the as received worked hardened and annealed material, were determined. Microhardness measurements did not reveal any significant influence of the annealing or subzero heat treatments on the mechanical behavior of the alloy.
166

Avalia??o de concreto com adi??o de fibras de PET submetido a altas temperaturas / Assessment of concrete made with de PET fiber exposedo to high temperatures

Meneses, Ilzenete Andrade 28 December 2011 (has links)
Made available in DSpace on 2014-12-17T14:48:12Z (GMT). No. of bitstreams: 1 IlzeneteAM_DISSERT.pdf: 5171535 bytes, checksum: 3ffff6c7a33112292923ae5183a28ef1 (MD5) Previous issue date: 2011-12-28 / The concrete for centuries constituted an essential structural element in the construction industry due to its relative ease of forming, before the weather durability, low cost, its lower maintenance compared to other materials such as steel. However, when the concrete is exposed to high temperatures tends to lose its mechanical characteristics, and may even result in loss of section, which undermines the stability and mechanical strength of structural elements. The pathologies resulting from exposure to elevated temperatures ranging from cracks, pops up chipping explosives (spalling). Recently, the technology of concrete is closely related to the study of its microstructure. The use of fibers added to concrete has been revealed as a solution to increase the mechanical strength of the concrete, it acts directly on the distribution of efforts to act in the play within the microstructure. In this work we used recycled PET fibers embedded in concrete with 15x2mm fck = 30MPa, water/cement ratio of 0.46, in works made for verification of mechanical strength of this mixture submitted to high temperature. The specimens of concrete with addition of PET fibers were tested after exposure to temperatures: ambient (30?C), 100?C, 200?C, 300?C, 400?C, 600?C and 900?C. It was found that the concrete loses significant strength when exposed to temperatures above 300?C, however the use of fiber PET may delay the risk of collapse of structures for the formation of a network of channels that facilitate the escape of vapor 'water, reducing the pore pressure inside the structural element / O concreto ao longo dos s?culos constituiu-se num elemento estrutural indispens?vel na constru??o civil, devido a sua relativa facilidade de moldagem, sua durabilidade diante das intemp?ries, seu baixo custo, sua menor necessidade de manuten??o, se comparado a outros materiais, como o a?o. No entanto, quando o concreto fica exposto a altas temperaturas tende a perder suas caracter?sticas mec?nicas, podendo inclusive ocorrer perda de se??o, que compromete a estabilidade e a resist?ncia mec?nica dos elementos estruturais. As patologias decorrentes da exposi??o ? elevadas temperaturas v?o desde as fissuras, estalos at? lascamentos explosivos. Nos ?ltimos tempos, a tecnologia do concreto est? intimamente ligada ao estudo de sua microestrutura. O uso de fibras adicionadas ao concreto tem se revelado como solu??o para o incremento de resist?ncia mec?nica do concreto, pois atua diretamente na distribui??o dos esfor?os que atuam na pe?a no ?mbito da microestrutura. Neste trabalho foram usadas fibras de PET proveniente da reciclagem de garrafas de refrigerante, para fabrica??o de vassouras. As fibra utilizadas tinham 2mm de largura por 15mm de comprimento, incorporadas ao concreto dosado para fck= 30MPa, rela??o ?gua/cimento 0.46, confeccionado em um canteiro obra, para verifica??o de resist?ncia mec?nica dessa mistura submetida ? elevadas temperaturas. Os corpos de prova dos concretos com e sem adi??o de fibras de PET foram ensaiados ap?s exposi??o ?s temperaturas: ambiente (30?C), 100?C, 200?C, 300?C, 400?C, 600?C e 900?C. Verificou-se que o concreto perde de forma significativa resist?ncia mec?nica quando exposto a temperaturas maiores que 300?C. No entanto o uso da fibra de PET pode retardar o risco de colapso de estruturas pela forma??o de uma rede de canais que facilitam a fuga do vapor d??gua, reduzindo a poropress?o no interior do elemento estrutural
167

Efeitos da dopagem nas propriedades elétricas do sistema supercondutor BSCCO com elemento terra rara /

Rodrigues, Vivian Delmute. January 2011 (has links)
Orientador: Cláudio Luiz Carvalho / Banca: Rafael Zadorosny / Banca: Carlos Yujiro Shigue / Resumo: Com a descoberta dos supercondutores de alta temperatura crítica na década de 80, as propriedades elétricas desses materiais passaram a ser intensamente estudadas, principalmente por meio do processo de dopagem. Desta forma, este trabalho teve por objetivo estudar os efeitos da dopagem nas propriedades elétricas do sistema supercondutor BSCCO com fórmula estequiométrica Bi1,6Pb0,4Sr2-xRExCa2Cu3O10+δ, por meio da substituição do elemento terra rara (RE), lantânio (La), em sítios de Sr, onde 0≤x≤2,0, em intervalos de 0,5. As soluções precursoras foram preparadas baseadas no método de Pechini, obtendo-se uma resina polimérica submetida a tratamento térmico de 200oC/10h, resultando em um material na forma de pó, o qual foi levado novamente a tratamento térmico entre 400oC a 810oC. Com o pó, foram preparadas pastilhas, submetendo-as a um novo tratamento térmico de 810oC/+31h. Para se conhecer as principais características das amostras, foram feitas a caracterização estrutural por meio da técnica de Difratometria de Raios X (DRX) para todos os tratamentos térmicos realizados; a caracterização elétrica, pelo método de quatro pontas dc; para a caracterização morfológica e química, a técnica de microscopia eletrônica de varredura (MEV), juntamente com a técnica de Espectroscopia por Energia Dispersiva de Raios X (EDX); e medidas magnéticas ac e dc para a caracterização magnética das amostras. Os resultados apontaram uma degradação das propriedades de supercondução, além de mudanças estruturais, morfológicas e magnéticas com o aumento da concentração de dopante / Abstract: With the discovery of high critical temperature superconductors in the 80, the electrical properties of these materials became intensively studied, mainly through the doping process. Thus, the objective of this work was the study of the effects of doping on the electrical properties of BSCCO superconducting system with stoichiometric formula Bi1,6Pb0,4Sr2-xRExCa2Cu3O10+δ, by the substitution of rare earth element (RE), lanthanum (La) in the sites of Sr, where 0 ≤ x ≤ 2.0, in interval of 0.5. The precursor solutions were prepared based by Pechini method, obtaining a polymer resin subjected to heat treatment at 200° 10h, which results in a material in C/ a powder. In sequence, futher heat treatments between 400oC to 810oC were made. With the powder were prepared bulks by subjecting them to a new heat treatment at 810° C/+31h. To know the main characteristics of the samples, structural characterization were made by the technique of X-Ray Diffraction (XRD) for all heat treated samples; the electrical characterization was made by the dc four probe method; for the morphological and chemical characterization by the technique of Scanning Electron Microscopy (SEM), together with the technique of Energy Dispersive X-ray Spectroscopy (EDX); and ac and dc magnetic measurements to magnetic characterization of the sample. The results shown a degradation of superconducting properties, as a consequence of structural, morphology and magnetic changes with the dopant concentration increase / Mestre
168

Avaliação da suscetibilidade da alvenaria estrutural a danos por exposição a altas temperaturas com medidas de controle da dilatação

Menegon, Julia January 2017 (has links)
A alvenaria estrutural é um dos mais antigos sistemas construtivos existentes. Atualmente estruturas em alvenaria encontram uma vasta aplicação em construções residenciais, sobretudo em obras de interesse social. No entanto, ao contrário das estruturas de concreto, cujo comportamento durante exposição ao fogo e sua resistência residual tem estudos e resultados amplamente disseminados, pouco se sabe a respeito do comportamento de estruturas de alvenaria submetidas à ocorrência de sinistros dessa natureza. Com a intensificação das preocupações acerca da segurança das edificações e de seus usuários em situações de incêndio, faz-se cada vez mais imprescindível o conhecimento do comportamento dos sistemas empregados atualmente na construção civil perante a ação de altas temperaturas. Tendo isso em vista, o presente trabalho teve por objetivo a realização de uma análise dos danos e do comportamento apresentados por amostras de alvenaria com função estrutural ao serem expostas ao aquecimento excessivo. Foram avaliadas nesse estudo paredes de pequenas dimensões executadas com blocos estruturais cerâmicos. Visando simular condições mais próximas da realidade, foram restringidas, com o auxílio de macacos hidráulicos, as laterais das amostras, para que houvesse contenção da dilatação das mesmas. Com o intuito de verificar diferentes tipologias de alvenarias, foram utilizados três blocos distintos: de 14 cm de largura, com resistências de 7 e 10 MPa, e de 19 cm de largura, com 7 MPa de resistência à compressão. Também foram variadas as espessuras das juntas entre as unidades e a argamassa de assentamento das mesmas, a fim de compreender a importância desses fatores para o comportamento das amostras, e, por fim, foram ensaiadas amostras com revestimento na face exposta As miniparedes foram acopladas a um forno de resistências elétricas e submetidas a um aquecimento próximo à curva padrão determinada por norma, até a temperatura máxima de 950ºC, a qual foi mantida pelo período de 4 horas. Foram mensurados, além da temperatura dentro do forno, no interior da parede e na superfície das amostras, os deslocamentos transversais ocorridos durante o ensaio. Também se utilizaram transdutores de deslocamento para verificar a dilatação dos blocos e o esmagamento ou abertura das juntas. Imagens termográficas da face oposta ao aquecimento foram capturadas no decorrer da exposição. Ao final das análises, pôde-se inferir que as miniparedes ensaiadas apresentaram bom desempenho frente à ação das altas temperaturas, mantendo sua estanqueidade, isolamento térmico e resistência mecânica. A restrição lateral não ocasionou desplacamentos dos blocos, no entanto, pôde-se observar transferência de tensão para os mesmos quando utilizadas nas juntas argamassas pouco flexíveis. O deslocamento transversal apresentado pelas amostras indicou deflexão em direção ao forno durante o aquecimento, com posterior reversão do sentido. Tal deflexão foi atenuada pela redução da espessura das juntas, pelo uso de argamassas menos flexíveis e pelo aumento da resistência e largura dos blocos. As alvenarias de 19 cm de largura e, especialmente, as dotadas de revestimento apresentaram melhor desempenho térmico que as demais. / Structural masonry is one of the oldest existing building systems. Nowadays, masonry structures find a wide application in residential constructions, mainly in those with social interest. However, unlike concrete structures, whose behavior during fire exposure and its residual resistance have widely disseminated studies and results, there is a lack of knowledge about the behavior of masonry structures submitted to fire. Because of the spread of concerns about the safety of buildings and their users in fire situations, it becomes essential to know the behavior of the systems currently used in civil construction when exposed to high temperatures. With this in view, the present study intended to analyze the damage and the behavior of structural masonry samples exposed to heating. This study evaluated clay hollow-bricks small walls, and, in order to simulate real conditions, the boundaries of the samples were restrained, with the aid of hydraulic jacks, aiming to restrain the deformation. In order to verify different types of masonry, three different blocks were used: 14 cm wide, with nominal strength of 7 and 10 MPa, and 19 cm wide, with 7 MPa of compressive strength. The thicknesses of the joints and the mortar were also varied, in order to understand the importance of these factors in the behavior of the samples, and, finally, samples were tested with a mono-layer coating at the exposed face. The small walls were coupled to an electrical furnace and subjected to a heating approximately equal to the standard curve, up to the maximum temperature of 950ºC, which was maintained for 4 hours The deflections of the samples during the test were measured, beyond the temperature inside the furnace, in the center of wall and at the non-exposed surface. Clip gages were also used to verify the expansion of the blocks and the crushing or opening of the mortar joints. Thermographic images of the opposite face were captured during the testing. At the end of this research, it was possible to affirm that the walls had good behavior against the high temperatures, maintaining their integrity, thermal insulation and load-bearing capacity. The restriction of the boundaries did not cause the spalling of the blocks, however, it was possible to observe the stress transfer to them in samples with rigid joint mortar. The deflection of the samples increases towards the furnace during the heating, and, then, they show the phenomenon of “reverse bowing”, changing the direction of the displacements. Reducing the thickness and increasing the stiffness of the joint mortars, as well as the increase in block strength and width attenuated such deflection. The masonry 19 cm width and, specially, the ones with coating shows better thermal performance, comparing to the others.
169

Estudo teórico-experimental da influência do teor de umidade no fenômeno de spalling explosivo em concretos expostos a elevadas temperaturas / A numerical and experimental analysis of the influence of water content on explosive spalling phenomena in concretes exposed to elevated temperatures

Kirchhof, Larissa Degliuomini January 2010 (has links)
Os concretos de alta compacidade, com resistências elevadas (acima de 40 MPa), estão começando a ser cada vez mais usados em obras de infraestrutura e em edificações de grande porte, devido às importantes vantagens que os mesmos oferecem em termos de capacidade de carga e durabilidade. Um dos pontos acerca de seu desempenho que levanta dúvidas envolve o seu comportamento frente a elevadas temperaturas. Evidências coletadas em incêndios ocorridos em estruturas reais, como o do Channel Tunnel e do Mont Blanc Tunnel, indicaram que, sob certas circunstâncias, existe a possibilidade de ocorrência de um fenômeno, conhecido como spalling explosivo, que causa sérios danos por lascamento ao material, incrementando de forma significativa a degradação térmica. Isso ocorre porque a reduzida porosidade e a baixa permeabilidade favorecem o aprisionamento do vapor de água nos poros, gerando um acréscimo da pressão interna que ocasiona tensões que podem superar a resistência à tração do concreto. O processo de spalling, bem como a sua probabilidade e severidade de ocorrência, dependem de uma série de fatores interdependentes que influenciam o comportamento do material. Contudo, está se formando um consenso de que o teor de umidade é o parâmetro mais influente para o desencadeamento do processo. Estudos efetuados após o reconhecimento da existência do spalling explosivo demonstraram que o mesmo tende a ocorrer somente quando o concreto apresenta teores muito elevados de umidade em sua estrutura de poros. Isso restringe a preocupação a certos tipos de elementos onde o concreto pode estar muito úmido por ocasião do sinistro. Embora estes sejam casos raros, a gravidade dos danos devido ao spalling explosivo justifica que se investiguem as condições nas quais o mesmo pode acontecer e se implementem medidas mitigatórias. Dado o caráter recente das investigações sobre o tema, ainda existe uma carência de estudos específicos que apontem quais as combinações críticas de porosidade e teores de umidade que desencadeiam o fenômeno. Este trabalho foi concebido para ajudar a superar essa lacuna de conhecimento, coletando dados sobre as condições que favorecem o spalling explosivo, bem como averiguando quais são as propriedades mecânicas residuais e as alterações na microestrutura sofridas por concretos com vários patamares de resistência submetidos a altas temperaturas. O trabalho utiliza os dados coletados para fundamentar a proposição de um modelo simplificado de spalling, elaborado com o objetivo de prover uma forma de considerar os efeitos do fenômeno durante uma análise termomecânica. Essa é uma necessidade fundamental para complementar os softwares atualmente utilizados para analisar os efeitos de incêndios sobre estruturas. O módulo de spalling foi implementado computacionalmente de forma que pudesse ser utilizado em consórcio com a ferramenta computacional VULCAN, o que permitiu simular a ocorrência do fenômeno na deterioração de uma viga durante um incêndio. Os resultados indicaram que a perda de seção transversal causada pela ocorrência do spalling explosivo reduz substancialmente o tempo de resistência ao fogo (TRRF), devido à aceleração dos danos e à redução da capacidade portante dos elementos estruturais de concreto. Conclui-se, portanto, que é fundamental considerar a possibilidade de lascamentos explosivos em estruturas suscetíveis ao fenômeno. De acordo com o presente estudo, estas incluem aquelas fabricadas com concretos de resistência maior que 40 MPa, que apresentem grau de saturação em torno ou superiores a 90%. / In the last years, the utilization of high-strength concrete (HSC) in the construction industry, with compressive strength grades greater than 40 MPa, has become wide spread due to remarkable characteristics of durability and load bearing capacity. However, the increased use of HSC has raised concerns regarding the behaviour of such concretes in fire. Evidences which were collected from structures exposed to the effects of fires, like Channel Tunnel and Mont Blanc Tunnel, have indicated that there is a possibility of the occurrence of explosive spalling in this condition. The phenomenon causes serious damages to the material and raises its thermal degradation in a significant way. This occurs because of its low porosity and permeability that contribute for the vapour pressure build-up in the pores, generating stresses which can exceed tensile strength of the material. The probability and severity of spalling process depend on a large number of inter-dependent factors that influence the behaviour of HSC in an unexpected manner. There is a consensus that the moisture content is one of the principal factors of the occurrence of explosive spalling. Recent investigations have demonstrated that spalling tends to occur only when the moisture content in the pores of concrete is elevated. Although fire is considered an exceptional event, the seriousness of spalling in concrete structures justifies the investigation of conditions in that the phenomenon can be happen and the implementation of preventive measures. In spite of the recent advances about the spalling process in HSC at high temperatures, there is still a lack of information in relation to the critical combinations of factors which affect the spalling occurrence. This work intends to help overcoming this lack of knowledge from the experimental data analysis with the purpose of establishing some critical conditions which collaborate in the spalling process as well as investigating the residual mechanical properties and changes in the microstructure of different concrete grades submitted to high temperatures. In addition, the experimental data are used to validate the proposition of a simplified model of spalling which was developed with the objective to take into account the effects of spalling in the thermo-mechanical analysis. This is an important need to complement the fire analysis of concrete structures. The spalling model was incorporated in the VULCAN software to simulate the phenomenon occurrence in a concrete beam exposed to fire. The results shown that the loss of mass in the beam cross-section, caused by spalling, reduces substantially its required time of fire resistance whereas it accelerates the damage in the concrete and aids the reduction of load bearing capacity of structural element. In conclusion, it is essential to consider the possibility of concrete spalling mainly in concrete grades greater than 40 MPa that present a saturation degree higher than 90%.
170

Estudo do comportamento da aderência em elementos de concreto armado submetidos à corrosão e elevadas temperaturas / Study of the bonding behavior of reinforced concrete elements subjected to extreme conditions

Caetano, Luciane Fonseca January 2008 (has links)
O estudo do comportamento de aderência tem recebido grande atenção desde o final da década de 40, entretanto muitas incertezas persistem no que tange à definição do melhor método de ensaio e do desempenho esperado ao longo da vida útil de uma estrutura, especialmente quando a mesma está exposta a condições ambientais desfavoráveis. A corrosão da armadura e a degradação térmica devida à exposição a altas temperaturas são exemplos de situações onde ocorrem importantes modificações nas propriedades dos materiais envolvidos, tendo forte impacto no desempenho da aderência. Tendo em vista que esta é uma propriedade de fundamental importância para a adequada transferência de esforços e compatibilização de deformações entre o concreto e o aço, colaborando para um bom desempenho global da estrutura, o estudo destes efeitos é vital. Este trabalho propõe a elaboração de um modelo matemático que represente o comportamento de aderência de peças submetidas à corrosão de armadura e à exposição a elevadas temperaturas. Além disto, busca realizar uma comparação entre os resultados obtidos por três métodos distintos de ensaios. Para a elaboração do modelo matemático foram produzidos cps de concreto com diferentes resistências à compressão, nos quais foram inseridas barras de aço de distintos diâmetros, para capturar a influência destas variáveis independentes. A modelagem estatística utilizou o modelo cubo-estrela, com definição de 5 níveis de referência para as variáveis temperaturas de exposição (ambiente, 200°C, 400°C, 600°C e 800°C), taxa de corrosão (0, 3, 6, 9 e 12% de perda de massa) e diâmetro da barra (8, 12.5, 16, 20 e 25 mm); e de 3 níveis para a resistência do concreto (25, 45 e 65 MPa). A determinação do comportamento de aderência foi executada através de duas técnicas de ensaio, selecionadas dentre as várias descritas na literatura: o ensaio de arrancamento simples (pull-out test), recomendado pela RILEM (1973), e o ensaio de arrancamento excêntrico (cantilever bond test), proposto por KEMP ET AL (1968). Ambas se caracterizam por serem ensaios de arrancamento, entretanto a primeira apresenta somente tensões de tração e de compressão e a segunda apresenta, além das tensões de tração e compressão, as de cisalhamento e de flexão, gerando uma situação mais próxima do que ocorre em estruturas reais. Para permitir a comparação entre métodos de ensaio com filosofias diferentes, mais uma técnica foi selecionada, o ensaio de viga (beam test), também recomendado pela RILEM (1973). De acordo com a análise dos resultados, o ensaio de arrancamento simples e de viga fornecem, respectivamente, valores de tensão de aderência, cerca de, 70% e 150% superiores aos obtidos em ensaios de arrancamento excêntrico. Os dados indicam, ainda, que os efeitos de deterioração são extremamente importantes para avaliação do desempenho final da aderência. Percebe-se que, para temperaturas mais baixas, até aproximadamente 300°C, a temperatura não provoca alteração no desempenho da aderência, mas, a partir de 550°C, a redução é superior a 50%, para concretos de resistências elevadas (acima de 50 MPa). Já a corrosão apresenta comportamento diferenciado, resultando em um acréscimo de cerca de 17%, da tensão de aderência para baixas taxas de perda de massa e posterior perda de desempenho com o aumento desta. / The study of the bonding mechanism in reinforced concrete elements has received attention from researchers since the forties. Nonetheless, there are still doubts regarding test methods and long term performance, especially when the structure is subjected to aggressive environmental conditions. Rebar corrosion and thermal degradation due to exposure to high temperatures are important examples of instances when significant changes in material properties take place, resulting in alterations of bonding performance. The study of these effects are vital, given that bonding is a fundamental property to ensure the adequate transfer of tensile stresses and strains between concrete and the steel rebar, which ensures good structural behavior. The proposed research aims to generate a mathematical model to explain the bonding behavior of structural RC elements subject to chloride corrosion and exposure to fire conditions. Besides, it seeks to compare results obtained using 3 distinct test methods for bonding evaluation. To this end, concrete specimens with different compressive strengths (25, 45 e 65 MPa) were produced, and bars of various diameters (8, 12.5, 16, 20 e 25 mm) were inserted in them. A statistical approach was adopted to reduce the experimental matrix, using the cube-star model, with 5 reference levels for the variables temperature of exposure (laboratory, 200°C, 400°C, 600°C e 800°C), corrosion rates (0, 3, 6, 9 e 12% weight loss) and bar diameter; and 3 levels for the variable concrete compressive strength, as discussed above. The bonding resistance was determined using two test methods selected from the various methodologies discussed in the literature: the RILEM pull-out test (1973) and the cantilever bond test, proposed by KEMP ET AL in 1968. Both evaluate bonding stresses, but the second one introduces shear and bending forces that create a stress distribution more close to the one found in real concrete beams. In order to improve the comparison between test methods, another technique was used in the second part of the work. The chosen technique was the beam test recommended by RILEM in 1973. According of the test results the pull-out test and the beam test result, respectively, in bonding values 70% e 150% higher than the ones registered in the cantilever bond test. The data obtained indicates, also, that the deterioration effects are extremely important to evaluate the bonding performance. For lower exposure temperature, up to around 300°C, the bonding behavior is not affected by the heat. But when the temperature exceeds 550°C, the bonding loss is higher than 50%, for the concretes with higher compressive strength (> 50 MPa). The deterioration by corrosion improves slightly the bonding resistance (up to 20%) when corrosion rates are lower than 1.5%. However, when corrosion increases, the bonding capacity decreases quite rapidly.

Page generated in 0.092 seconds