• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 149
  • 126
  • 25
  • 16
  • 15
  • 10
  • 10
  • 9
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 451
  • 108
  • 71
  • 69
  • 57
  • 56
  • 49
  • 42
  • 35
  • 35
  • 34
  • 33
  • 31
  • 31
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
431

Acquired flatfoot in adults / Acquired flatfoot in adults

Khadura, Mohamed January 2017 (has links)
Title: Acquired flatfoot in adults Background: Flatfoot deformity is one of the common diagnoses in the orthopedic field and physiotherapy, its common in adults as acquired, there is still a large incidence of flatfoot in adolescence and many cases of adult flatfoot are frequently presented as residual pediatric flatfoot. The treatment also has wide field according to type of cause. Aims: The aim of this literature review was to enhance knowledge on the persistence of the acquired flatfoot condition in adult's population by determining the causes of flatfoot with contributing factors that affect the medial longitudinal arch and progression of the deformity, and review of the most common treatment. Method: An electronic database search was conducted to obtain articles from relevant journals (from early 1990 to end 2015). The information was collected also from textbooks. Results: Regarding the causes of acquired flatfoot in adult, a good base of evidence stems from a number of articles review, the posterior tibialis tendon dysfunction is the most cause of acquired flatfoot. The sensory motor stimulation technique is not the most treatment used to treat acquired flatfoot in adults and the most used treatment is the surgical procedure. Conclusion: Regarding the causes of adults acquired flatfoot in...
432

Effets d’un test de propulsion en fauteuil roulant sur l’intégrité tendineuse des muscles biceps et supra-épineux : étude d’imagerie musculosquelettique par ultrasonographie

Leclerc, Mylène 12 1900 (has links)
Pertinence. Compléter des tests d’endurance cardiorespiratoire maximaux basés sur la performance chez les utilisateurs de fauteuils roulants manuels est très pertinent pour développer des programmes d'entraînement cardiorespiratoire personnalisés et pour évaluer leurs impacts au fil du temps. Cependant, ces tests augmentent potentiellement l’exposition au risque de développement de troubles musculosquelettiques secondaires aux membres supérieurs, particulièrement aux épaules. Par conséquent, il est fondamental de trouver un équilibre entre la nécessité de mesurer la capacité aérobie et le risque accru de développer des troubles musculosquelettiques secondaires lors de la réalisation d'un test basé sur les performances. Objectif. Caractériser les effets de la performance d’un test de propulsion progressif par paliers sur tapis roulant sur l'intégrité des tendons de la longue portion du biceps et du supra-épineux en utilisant des biomarqueurs obtenus via l'imagerie musculosquelettique par ultrasonographie. Méthode. Quinze utilisateurs de fauteuils roulants manuels vivant avec une lésion chronique de la moelle épinière ont complété le test de propulsion progressif par paliers sur tapis roulant. Des images des tendons de la longue portion du biceps et du supra- épineux ont été enregistrées avec un appareil d’imagerie musculosquelettique par ultrasonographie dans les plans transversal et longitudinal avant, immédiatement après et 48 heures après la fin du test en suivant un protocole standardisé. Des biomarqueurs ultrasonographiques liés à la géométrie, à la luminosité et à la texture d’une région d’intérêt ont permis de caractériser l'intégrité des tendons. Résultats. Les participants ont propulsé en moyenne pendant 10,2 ± 2,9 minutes alors que la majorité d’entre eux (N = 13/15) a atteint au moins le huitième stade du test (vitesse = 0,8 m / s; pente = 3,6 ̊). Aucun des biomarqueurs géométriques, de luminosité et de texture caractérisant l'intégrité des deux tendons, mesurés dans les plans longitudinal et transverse, n’a changé de façon significative (p = 0,063 à 1 000) entre les trois temps de mesure. Conclusion. La performance du test de propulsion progressif par paliers sur tapis roulant motorisé pour évaluer la capacité aérobie n'amène aucun changement délétère observable immédiatement après et 48 heures après la réalisation du test. / Relevance. The completion of performance-based maximal cardiorespiratory fitness tests among manual wheelchair user is highly relevant to develop personalized cardiorespiratory fitness training programs and to assess their impacts over time. However, these tests could potentially increase risk exposure for the development of upper limb secondary musculoskeletal impairments specifically to the shoulder. Hence, finding an equilibrium between the need to measure aerobic fitness and the increased risk of developing secondary musculoskeletal impairments when completing performance-based test is fundamental. Objective. To characterize the effect of the completion of a recently- developed treadmill-based progressive workload incremental test on the integrity of the long head of the biceps and supraspinatus tendons using musculoskeletal ultrasound imaging biomarkers. Method. Fifteen manual wheelchair users living with a spinal cord injury completed the treadmill-based progressive workload incremental test. Ultrasound images of the long head of the biceps and supraspinatus tendons were recorded with a musculoskeletal ultrasound imaging device in the transversal and longitudinal planes before, immediately after, and 48 hours after the completion of the test using a standardized protocol. Geometric, luminosity, and texture-related ultrasound biomarkers of a region of interest have characterized tendon integrity. Results. The participants propelled an average of 10.2 ± 2.9 minutes with the majority (N = 13/15) reached at least the eighth stage of the test (speed = 0.8 m/s; slope = 3.6 ̊). None of the geometric, luminosity and texture biomarkers characterizing the integrity of the two tendons, measured in the longitudinal and transversal planes, changed significantly (p=0.063 to 1.000) between the three measurement times. Conclusion. The performance of the treadmill-based progressive workload propulsion test to assess aerobic capacity does not result in any observable deleterious change immediately after and 48 hrs after the performance of the test.
433

Statické zajištění kostela v Ludslavicích / Static securing of Ludslavice church

Kovalíková, Mária January 2015 (has links)
This thesis is drafting static protection church horizontal pretension, especially at the level of foundations and walls. Furthermore, the design of a new increase the stiffness of reinforced concrete towers and other prestress. The role was also producing construction drawings for the design of static security.
434

Analýza rizikových faktorů pro vznik tendinopatií u běžců - literární rešerše / Analysis of risk factors for development of tendinopathies in runners - literature review

Voleský, Kryštof January 2021 (has links)
Title: The analysis of risk factors for tendinopathy in runners Objectives: The aim of this thesis is to find out the most important risk factor for development of Achilles tendinopathy, detect the most relevant diagnostic approach with preventive monitoring for Achilles tendinopathy and evaluate the best treatment for Achilles tendinopathy in runners. Methods: The diploma thesis is in form of literary review. The Scopus, PubMed and Web of science databases were used to search for studie using a combination of keywords. A total of 1084 titles were identified. Due to duplicates 402 titles were excluded. On the basis of the name of the article 51 titles were included. On the basis of the availability 50 titles were included. On the basis of the abstract 46 titles were included. Finally 29 titles were included in this review. Results: The most important risk factor for development of Achilles tendinopathy was training intensity for distances 1500-3000 m, week running volume >65 km or being new to running. The most relevant diagnostic approach for Achilles tendinopaty was clinical examination assessing pain (Achilles tendon pain, positive palpation test) and function (pain during physical aktivity) of Achilles tendon. This approach serves as indication for sonographic assessment of Achilles tendon...
435

Fluoreszenzkinematografische Untersuchung zur Sehnendehnbarkeit an der equinen oberflächlichen Beugesehne

Wagner, Franziska C. 04 February 2022 (has links)
Einleitung: Die oberflächliche Beugesehne (OBS) ist die am häufigsten verletzte Struktur des Bewegungsapparates von Pferden. Verletzungen der OBS verursachen ökonomische Einbußen im Pferdesport, sind unter Tierschutzaspekten hochrelevant und sind gekennzeichnet von langen Rekonvaleszenzzeiten von 9--18 Monaten und einer Wiederverletzungsrate von bis zu 80 %. Um Sehnenverletzungen, deren Heilung und den Therapieerfolg zu detektieren, bedarf es grundlegender Kenntnisse der Sehnenbiomechanik. Zur Anwendung kommende Messmethoden sollten idealerweise hochpräzise, minimalinvasiv und über einen längeren Zeitraum einsetzbar sein. Bislang etablierte Methoden genügen diesen Ansprüchen nur teilweise. Daher soll biplanare Hochfrequenz-Fluoreszenz-Kinematografie (FluoKin) als aktueller Goldstandard für Bewegungsstudien auf ihren Einsatz an equinen Sehnengewebe geprüft werden. Ziele der Untersuchungen waren es daher, 1) die Messgenauigkeit von FluoKin zu bestimmen und hinsichtlich Dehnbarkeitsmessungen equiner OBS zu evaluieren, 2) eine Technik zur Nutzung von FluoKin (3D-Röntgenmethode) zu finden, um die Bewegung eines Weichteilgewebes im Röntgenvideo zu visualisieren, 3) diese Methodik in zyklischen Zugprüfversuchen mit gesunden und Kollagenase-geschädigten OBS ex vivo zu prüfen und dafür eine geeignete Haltevorrichtung für die Sehnen zu entwickeln, 4) in einem Pilotversuch die Technik in vivo zu übertragen und in wiederkehrenden Messserien die Dehnung von gesundem, verletztem und heilendem Sehnengewebe zu messen. Tiere, Material und Methoden: Die Präzisionsmessungen wurden mit einem maßgefertigten Testplättchen und einer gefrorenen distalen Vordergliedmaße (VGlm) jeweils statisch (1976 und 5473 Bilder) und in Bewegung (2816 und 5021 Bilder) durchgeführt. Die Sehnenhaltevorrichtung inkl. Kryo-Klemme wurde neben dem Einsatz in der Ex-vivo-Studie zusätzlich Langzeittests (bis 50 min) und Rupturversuchen bis 10 kN (Maschinenlimit) unterzogen. Im Rahmen der Ex-vivo-Zugprüfversuche wurden 13 OBS von VGlm in Schritt (2 %)- und Trab (4 %)-simulierender Dehnung zyklisch getestet. Vier weitere Proben wurden mit Kollagenase inkubiert und inkl. einer Kontrollgruppe (n=4) bei 6 % getestet. Die biomechanischen Kenngrößen wurden von der Zugprüfmaschine erfasst und anhand der Bewegung von implantierten, röntgendichten Markern in zeitgleich aufgenommenen FluoKin-Videos errechnet. In der In-vivo-Langzeitstudie (37 Wochen) wurde in vier FluoKin-Messungen das Dehnverhalten der OBS beider VGlm eines Shetland Ponys in Schritt und Trab ermittelt. Vor der zweiten FluoKin-Messung wurde im mittleren metakarpalen Segment einer OBS eine Sehnenläsion mit Kollagenase induziert, deren Heilungsverlauf verfolgt wurde. Die Ergebnisbeschreibung erfolgte sowohl deskriptiv als auch bei entsprechender Stichprobengröße mit t-Tests (p<0,05). Ergebnisse: In Präzisionsmessungen wurden sowohl die Messgenauigkeit der FluoKin-Anlage (max. Exaktheit von 0,0287 mm ± 0,0377 mm), als auch die zu erwartende Standardabweichung in der studienrelevanten Region (Os metacarpale III, OBS) ermittelt. Im Rahmen der Ex-vivo-Zugprüfversuche wurde eine Haltevorrichtung inkl. Kryo-Klemme für equine OBS entwickelt, welche Probleme herkömmlicher Einspanntechniken zuverlässig löst. Erstmals konnten biomechanische Kenngrößen für die OBS von Shetland Ponys ermittelt werden. Im Mittel konnten abhängig von der Dehnungsrate (simulierter Schritt und Trab) eine Maximalkraft von 325 bzw. 953 N, eine Zugfestigkeit von 1649 bzw. 4820 N/cm² und ein Elastizitätsmodul von 828 bzw. 1212 MPa verzeichnet werden. Nach Inkubation mit Kollagenase stieg die Längenänderung im Mittel um 4,87 %. In vivo konnte die Dehnungszunahme der geschädigten OBS im Schritt bestätigt werden (2,86 % auf 3,38 %); im Trab zeigte sich hingegen ein Abfall (6,78 % auf 5,96 %). Schlussfolgerungen: FluoKin wurde als hochpräzise und minimalinvasive Messtechnik zur Ermittlung der Sehnendehnung equiner OBS ex vivo und erstmals in vivo erfolgreich eingesetzt. Dank der neu entwickelten Haltevorrichtung inkl. Kryo-Klemme konnten langandauernde Ex-vivo-Zugprüfversuche durchgeführt werden. Hierbei zeigten sich Änderungen des Dehnverhaltens der OBS (Konditionierung, Hysterese, Kriechphänomen), was die Notwendigkeit solcher Versuche für die Beschreibung des biomechanischen Verhaltens von Sehnen verdeutlicht. Der In-vivo-Pilotversuch unterstreicht die Bedeutung von FluoKin für innovatives und hochpräzises Monitoring von Sehnenläsionen in Langzeitstudien.:1 Einleitung 2 Literaturübersicht 2.1 Sehnengewebe 2.1.1 Histologischer und molekularer Aufbau 2.1.2 Biomechanik 2.1.3 Einflüsse auf die Sehnenstruktur und -zusammensetzung 2.2 Tendinopathien der oberflächlichen Beugesehne 2.2.1 Ätiologie 2.2.2 Heilung 2.3 Möglichkeiten zur Bestimmung der Sehnendehnbarkeit 2.3.1 Ex-vivo-Zugprüfversuche mit Sehnen 2.3.2 In-vivo-Ermittlung der Sehnendehnbarkeit 2.4 Zentrale Fragestellungen 3 Publikation 1 Zyklische Zugprüfversuche mit einer neuartigen Kryo-Klemme an oberflächlichen Beugesehnen von Shetland Ponys kombiniert mit biplanarer Hochfrequenz-Fluoreszenz-Kinematografie 4 Publikation 2 Biplanare Hochfrequenz-Fluoreszenz-Kinematografie an der oberflächlichen Beugesehne eines Shetland Ponys – eine In-vivo-Pilotstudie 5 Diskussion 5.1 Diskussion von Material und Methoden 5.1.1 Ermittlung der Messgenauigkeit von FluoKin 5.1.2 Verwendetes Tiermaterial 5.1.3 Implantationstechnik für Sehnenmarker 5.1.4 Aufbau der Ex-vivo-Zugprüfversuche 5.2 Bestimmung der Sehnendehnbarkeit mit FluoKin 5.2.1 Sehnendehnung ex vivo und in vivo in nativem Sehnengewebe 5.2.2 Sehnendehnung ex vivo und in vivo in Kollagenase-geschädigtem Sehnengewebe 5.3 Schlussfolgerungen und Ausblick 5.3.1 Praktische und klinische Relevanz 5.3.2 Fazit und Perspektiven 6 Zusammenfassung 7 Summary 8 Literaturverzeichnis 9 Anhang 9.1 Bauplan des Messplättchens zur Genauigkeitsbestimmung von FluoKin 9.2 Baupläne der Einspanntechnik für Zugprüfversuche mit equinen OBS 9.2.1 Kronbeinhalterung 9.2.2 Kryo-Klemmen 9.3 Genauigkeit von biplanaren Fluoroskopie-Systemen in Abhängigkeit des Versuchsaufbaus 9.4 Lagerungseinflüsse auf biomechanische Eigenschaften von Sehnengewebe 9.5 Vorträge und Präsentationen während der Doktorarbeitszeit / Introduction: The superficial digital flexor tendon (SDFT) is the most frequently injured structure of the musculoskeletal system of horses. Injuries of the SDFT are relevant under animal welfare aspects, cause substantial economic losses in equestrian sport and are associated by long convalescence times of 9 to 18 months and a re-injury rate of up to 80 %. In order to detect tendon injuries, improve their healing and the success of therapy, fundamental knowledge of tendon biomechanics is required. The measurement methods to be used should ideally be highly precise, minimally invasive and applicable over a long period of time. So far, established methods only partially meet these requirements. Therefore, biplanar high-speed fluoroscopic kinematography (FluoKin) as the current gold standard for movement studies will be tested for its use on equine tendon tissue Aims of the study were therefore 1) to determine the measurement accuracy and precision of FluoKin and to evaluate it with regard to measurements on the equine SDFT, 2) to find a technique for using FluoKin (a 3D X-ray method) for visualizing the movement of a soft tissue in X-ray video, 3) to test this methodology in cyclic tensile tests with healthy and collagenase-incubated SDFT ex vivo and to develop a suitable holding device for the tendons in the testing machine, 4) to transfer the technique in an in vivo pilot study on a pony and to measure the elongation of healthy, injured and healing tendon tissue in measurement series. Materials and Methods: Precision measurements were performed with a custom-made test sheet and a frozen distal forelimb static (1976 and 5473 frames) and in motion (2816 and 5021 frames) resp. The tendon holding device with a cryo-clamp was subjected to long-term cyclic tests (up to 50 min) and rupture tests up to 10 kN (machine limit) in addition to its use in the ex vivo study. As part of the ex vivo tensile testing, 13 SDFT of forelimbs were cyclically tested in walk (2 % strain) and trot (4 % strain) simulated elongation. Four additional specimens were incubated with collagenase and tested including a control group (n=4) at 6 % strain. Biomechanical parameters were recorded by the testing machine and calculated from the movement of implanted radiopaque markers in simultaneously recorded FluoKin videos. In the in vivo long-term study (37 weeks) the strain behaviour of the SDFT of both forelimbs of a Shetland pony at walk and trot were determined in four FluoKin measurements. Before the second FluoKin measurement, a tendon lesion was induced with collagenase in the mid-metacarpal segment of one SDFT, and its healing process was monitored. The description of the results was done both descriptively and, with an appropriate sample size, with t-tests (p<0.05). Results: Measurements to assess the precision of both the FluoKin system (max. accuracy of 0.0287 mm ± 0.0377 mm) and the standard deviation to be expected in the region relevant to the study (Os metacarpale III, SDFT). For the ex vivo tensile tests, a holding device with a cryo-clamp for equine SDFT was developed that reliably solved problems of conventional clamping techniques. For the first time, biomechanical parameters for the SDFT of Shetland ponies could be determined. On average, depending on the strain rate (simulated walk and trot), a maximum force of 325 N and 953 N resp., a tensile strength of 1649 N/cm² and 4820 N/cm² resp. and a modulus of elasticity of 828 MPa and 1212 MPa resp. was recorded. After incubation with collagenase, the change in length increased by an average of 4.87 %. In vivo, this increased elongation of the collagenase-injured SDFT could be confirmed at walk (2.86 % to 3.38 %); in contrast, a decrease in strain was observed at trot (6.78 % to 5.96 %). Conclusions: FluoKin was successfully used as a highly precise and minimally invasive measurement technique to determine the tendon strain of equine SDFT ex vivo and for the first time also in vivo. Thanks to the newly developed holding device with a cryo-clamp, long-term ex vivo tensile tests could be carried out and changes in the strain behaviour of the SDFT became apparent (conditioning, hysteresis, creep). This shows the necessity of such tests for the description of the biomechanical behaviour of tendons. The in vivo pilot study underlines the importance of FluoKin for innovative and highly accurate monitoring of tendon lesions in long-term studies.:1 Einleitung 2 Literaturübersicht 2.1 Sehnengewebe 2.1.1 Histologischer und molekularer Aufbau 2.1.2 Biomechanik 2.1.3 Einflüsse auf die Sehnenstruktur und -zusammensetzung 2.2 Tendinopathien der oberflächlichen Beugesehne 2.2.1 Ätiologie 2.2.2 Heilung 2.3 Möglichkeiten zur Bestimmung der Sehnendehnbarkeit 2.3.1 Ex-vivo-Zugprüfversuche mit Sehnen 2.3.2 In-vivo-Ermittlung der Sehnendehnbarkeit 2.4 Zentrale Fragestellungen 3 Publikation 1 Zyklische Zugprüfversuche mit einer neuartigen Kryo-Klemme an oberflächlichen Beugesehnen von Shetland Ponys kombiniert mit biplanarer Hochfrequenz-Fluoreszenz-Kinematografie 4 Publikation 2 Biplanare Hochfrequenz-Fluoreszenz-Kinematografie an der oberflächlichen Beugesehne eines Shetland Ponys – eine In-vivo-Pilotstudie 5 Diskussion 5.1 Diskussion von Material und Methoden 5.1.1 Ermittlung der Messgenauigkeit von FluoKin 5.1.2 Verwendetes Tiermaterial 5.1.3 Implantationstechnik für Sehnenmarker 5.1.4 Aufbau der Ex-vivo-Zugprüfversuche 5.2 Bestimmung der Sehnendehnbarkeit mit FluoKin 5.2.1 Sehnendehnung ex vivo und in vivo in nativem Sehnengewebe 5.2.2 Sehnendehnung ex vivo und in vivo in Kollagenase-geschädigtem Sehnengewebe 5.3 Schlussfolgerungen und Ausblick 5.3.1 Praktische und klinische Relevanz 5.3.2 Fazit und Perspektiven 6 Zusammenfassung 7 Summary 8 Literaturverzeichnis 9 Anhang 9.1 Bauplan des Messplättchens zur Genauigkeitsbestimmung von FluoKin 9.2 Baupläne der Einspanntechnik für Zugprüfversuche mit equinen OBS 9.2.1 Kronbeinhalterung 9.2.2 Kryo-Klemmen 9.3 Genauigkeit von biplanaren Fluoroskopie-Systemen in Abhängigkeit des Versuchsaufbaus 9.4 Lagerungseinflüsse auf biomechanische Eigenschaften von Sehnengewebe 9.5 Vorträge und Präsentationen während der Doktorarbeitszeit
436

The Effect of Mesenchymal Stromal Cells, Platelet-Rich Plasma, and Collagen on Rat Achilles Tendon Repair

Juzbasich, Dragan 16 December 2021 (has links)
No description available.
437

Tenogenic Properties of Mesenchymal Progenitor Cells Are Compromised in an Inflammatory Environment

Brandt, Luisa, Schubert, Susanna, Scheibe, Patrick, Brehm, Walter, Franzen, Jan, Gross, Claudia, Burk, Janina 22 December 2023 (has links)
Transplantation of multipotent mesenchymal progenitor cells is a valuable option for treating tendon disease. Tenogenic differentiation leading to cell replacement and subsequent matrix modulation may contribute to the regenerative effects of these cells, but it is unclear whether this occurs in the inflammatory environment of acute tendon disease. Equine adipose-derived stromal cells (ASC) were cultured as monolayers or on decellularized tendon scaffolds in static or dynamic conditions, the latter represented by cyclic stretching. The impact of different inflammatory conditions, as represented by supplementation with interleukin-1β and/or tumor necrosis factor-α or by co-culture with allogeneic peripheral blood leukocytes, on ASC functional properties was investigated. High cytokine concentrations increased ASC proliferation and osteogenic differentiation, but decreased chondrogenic differentiation and ASC viability in scaffold culture, as well as tendon scaffold repopulation, and strongly influenced musculoskeletal gene expression. Effects regarding the latter differed between the monolayer and scaffold cultures. Leukocytes rather decreased ASC proliferation, but had similar effects on viability and musculoskeletal gene expression. This included decreased expression of the tenogenic transcription factor scleraxis by an inflammatory environment throughout culture conditions. The data demonstrate that ASC tenogenic properties are compromised in an inflammatory environment, with relevance to their possible mechanisms of action in acute tendon disease.
438

Fatigue Testing of Human Flexor Tendons Using a Customized 3D-Printed Clamping System

Scholze, Mario, Safavi, Sarah, Ramezani, Maziar, Ondruschka, Benjamin, Hammer, Niels 06 December 2023 (has links)
Improved surgical procedures and implant developments for ligament or tendon repair require an in-depth understanding of tissue load-deformation and fatigue properties. Cyclic testing will provide crucial information on the behavior of these materials under reoccurring loads and on fatigue strength. Sparse data are available describing soft tissue behavior under cyclic loading. To examine fatigue strength, a new technology was trialed deploying 3D-printing to facilitate and standardize cyclic tests aiming to determine tendon fatigue behavior. Cadaveric flexor digitorum tendons were harvested and mounted for tensile testing with no tapering being made, using 3Dprinted clamps and holder arms, while ensuring a consistent testing length. Loads ranging between 200 to 510 N were applied at a frequency of 4 Hz, and cycles to failure ranged between 8 and >260,000. S–N curves (Woehler curves) were generated based on the peak stresses and cycles to failure. Power regression yielded a combined coefficient of determination of stress and cycles to failure of R 2 = 0.65, while the individual coefficients for tissues of single donors ranged between R 2 = 0.54 and R 2 = 0.88. The here-presented results demonstrate that S–N curves of human tendons can be obtained using a standardized setting deploying 3D-printing technology
439

Fysioterapeutiska utvärderingsinstrument för bedömning av funktion hos personer med akillesseneruptur : En kartläggande litteraturstudie / Physiotherapeutic outcome measures for the evaluation of function of people with Achilles tendon rupture : A scoping review

Petersson, Sofie, Ström, Pär January 2023 (has links)
Bakgrund: En akut akillesseneruptur (ATR) resulterar i begränsning av funktion som kan kvarstå under lång tid. I litteraturen finns ett flertal reliabla och valida utvärderingsinstrument som används vid funktionsbedömningar efter ATR. Då osäkerhet angående lämpligt val av tester inför återgång i aktivitet/idrott föreligger finns ett behov av tydliga riktlinjer i fråga om kliniskt relevanta utvärderingsinstrument. Syfte: Syftet med studien var att identifiera kliniskt relevanta fysioterapeutiska utvärderingsinstrument för bedömning av funktion hos personer med akillesseneruptur samt kartlägga dessa utifrån ett validitets och reliabilitetperspektiv. Metod: En kartläggande litteraturstudie. Litteratursökningen genomfördes i databaserna PubMed, Cinahl och PEDro mellan 2023-02-07 – 2023-02-15 utifrån inklusionskriterierna: vuxna individer med akut ATR, artiklar publicerade 2013-2023, observations- och randomiserade kontrollerade studier. Av identifierade utvärderingsinstrument valdes 15 ut, baserat på kriterierna: frekvens, klinisk användbarhet samt kategorisering enligt ramverket International Classification of Functioning, Disability and Health (ICF). Valda utvärderingsinstrument kategoriserades enligt ICF samt granskades avseende reliabilitet och validitet om denna data fanns tillgänglig. Resultat: Totalt inkluderades 15 olika utvärderingsinstrument, såväl objektiva som subjektiva, för granskning utifrån reliabilitet och validitet. Fem av dessa visade både god reliabilitet och validitet samt klinisk användbarhet. Inga diagnosspecifika utvärderingsinstrument inom ICF-kategorierna personlighetsfaktorer och omgivningsfaktorer identifierades. Slutsats: Achilles Tendon Resting Angle (ATRA), Achilles Tendon Total Rupture Score (ATRS), Foot and Ankle Outcomes Score (FAOS), Heel-Rise Endurence och Heel-Rise Height är fem tillförlitliga utvärderingsinstrumnet att använda i klinik. Inför återgång till aktivitet/idrott är det nödvändigt att komplettera med idrottsspecifika utvärderingsinstrument samt instrument som utvärderar psykologiska faktorer. / Background: An acute achilles tendon rupture (ATR) results in limitations of function that remains for a long time. There are several reliabel and valid outcome measures used in functional evaluation after ATR presented in the litterature. Due to uncertainties regarding which appropriate outcome measures to use for return to activities/sports there is a need for clinical guidelines. Purpose: The purpose was to identify physiotherapeutic outcome measures for the evaluation of function in people with achilles tendon ruptures and to chart these from a perspecive of reliability and validity. Method: A scoping review. A litterature search were performed in the databases PubMed, Cinahl and PEDro between 2023-02-07 – 2023-02-15 based on the inclusion criteria: adults with acute ATR, articles published between 2013-2023, clinical trials and randomized controlled trials. From identified outcome measures 15 were selected based on the criteria frequency, clinical usability and categorized by the theoretical framework International Classification of Functioning, Disability and Health (ICF). Selected outcome measures were categorized according to ICF and reviewed for republicity of results, if this data was available. Results: 15 outcome measures, both objective and subjective, were included for evaluation regarding reliability and validity. Five of these proved good reliability, validity and clinical usability. In the ICF categories, personal factors and environmental factors, no diagnose specific outcome measures were identified. Conclusion: Achilles Tendon Resting Angle (ATRA), Achilles Tendon Total Rupture Score (ATRS), Foot and Ankle Outcomes Score (FAOS), Heel-Rise Endurence och Heel-Rise Height are five reliable outcome measures to use in clinical practice. Before return to activities/sports it is necessary to add sportspecific outcome measures and evaluation of psychological factors.
440

Engineered carbon-based scaffolds for hard and soft tissue repair, reconstruction or regeneration

Czarnecki, Jarema S. January 2013 (has links)
No description available.

Page generated in 0.036 seconds