Sistema de aquisição de dados e comunicação sem fio para monitoramento de temperatura em silo de armazenamento de grãos /

Bica, Marcos Roberto Ruybal. January 2019 (has links)
Orientador: Alexandre Dal Pai / Banca: Roberto Lyra Villas Bôas / Banca: Francisco Sérgio dos Santos / Resumo: O presente trabalho apresenta o desenvolvimento e implantação de um sistema de aquisição de dados de temperatura, em um silo de armazenamento de grãos, carregado com milho. Os dados foram coletados no silo por um sistema Arduíno ao qual são acoplados os sensores de temperatura. Após a leitura os dados são transmitidos via rádio e exibidos em tempo real em uma tela de computador criada especificamente para que o usuário do sistema consiga identificar os pontos de medição rapidamente. Essa informação é importante para subsidiar o operador do sistema na tomada de decisão sobre intervir ou não no processo de aeração dos grãos para manter a qualidade do produto armazenado. Os dados coletados são armazenados e podem compor uma série histórica do comportamento da temperatura dos grãos durante o armazenamento, bem como serem utilizados em pesquisas acadêmicas. A parte experimental deste trabalho, corroborou para a validação do mesmo. O sistema contou com 12 sensores distribuídos dentro do silo, e as leituras foram realizadas com intervalo de 15 minutos no período entre 16 de julho e 18 de outubro de 2018. Nesse período foram coletados 104640 medidas de temperatura, que permitiram realizar diversas análises. Foi verificado que o sistema pode ser usado para avaliar como foi o comportamento térmico dos grãos e quais foram as reações do milhos depois de atuações para diminuição da temperatura. A partir da variação de temperatura entre o volume do silo sem grãos e com a presença dos mesmo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This paper presents the development and implementation of a temperature data acquisition system in a grain storage silo loaded with corn. Data were collected in the silo by an Arduino system to which the temperature sensors are coupled. After reading the data is transmitted by radio and displayed in real time on a computer screen specifically designed so that the system user can identify the measuring points quickly. This information is important to support the system operator in deciding whether or not to intervene in the grain aeration process to maintain the quality of the stored product. The collected data are stored and can compose a historical series of grain temperature behavior during storage, as well as being used in academic research. The experimental part of this work corroborated its validation. The system had 12 sensors distributed inside the silo, and the readings were taken with a 15-minute interval between July 16 and October 18, 2018. During this period 104640 temperature measurements were collected, which allowed to perform various analyzes. It was verified that the system can be used to evaluate how was the thermal behavior of the grains and what were the reactions of the corn after actions to decrease the temperature. From the temperature variation between the volume of the silo without grains and with their presence it is possible to estimate the volume occupied by the grain in it. / Mestre
22

Monitoramento de temperatura tecidual por meio de imagens fotoacústicas durante tratamento de hipetermia / Tecidual temperature monitoring using photoacoustic images during hyperthermia treatments.

Uliana, João Henrique 29 September 2016 (has links)
Sabe-se que o aumento na temperatura do tecido tumoral pode aumentar a eficiência de técnicas convencionais de combate ao câncer (radioterapia e quimioterapia). Além disso, a variação de temperatura em tumores pode ser uma forma de tratamento alternativo à cirurgia, feito por meio do fornecimento de calor direcionado às células cancerosas e preservando o tecido sadio. Para maior eficácia e segurança no emprego de técnicas que utilizam fornecimento de calor ao tecido biológico, é necessário o monitoramento da temperatura tecidual para garantir que a morte celular por ablação térmica seja limitada ao tecido alvo, minimizando os danos aos tecidos adjacentes. A imagem fotoacústica é uma técnica baseada no efeito fotoacústico, o qual consiste na absorção de radiação eletromagnética pelo tecido e, devido à expansão termoelástica, na geração de ondas acústicas. A amplitude da onda de pressão gerada pelo efeito fotoacústico possui dependência com a temperatura do meio pelo parâmetro de Grueneisen, que depende das propriedades mecânicas do material. Portanto, mudanças na amplitude do sinal fotoacústico carregam informações a respeito da variação na temperatura do material. Neste trabalho, a dependência da amplitude do sinal fotoacústico com a temperatura foi estudada em um material simulador de tecido biológico (phantom) em condições similares a de tratamentos por hipertermia Nesse caso, imagens fotoacústicas foram adquiridas para cada grau de temperatura em uma faixa de 36 até 41 ºC durante o procedimento de aquecimento por banho térmico. Mudanças na amplitude e fase do sinal fotoacústico foram avaliadas através da aplicação de algoritmos de speckle tracking. Para estimar a variação na amplitude do sinal também foram utilizados e avaliados diferentes métodos de comparação. Os resultados são apresentados por imagens fotoacústicas termais produzidas pela aplicação de um fator de calibração aos mapas de variação relativa da amplitude do sinal em função da temperatura do meio. Finalmente, avaliamos um experimento de hipertemia por ultrassom focalizado de alta intensidade (High Intensity Therapeutic Ultrasound - HITU) em uma amostra de músculo suíno. Nesse caso foram geradas imagens termais fotoacústicas e imagens termais produzidas pela mudança de fase do sinal pulso-eco de ultrassom. Os resultados sugerem uma maneira não invasiva de calcular a distribuição da variação de temperatura do meio que pode ser aplicada para monitoramento durante tratamentos que utilizam o fornecimento de calor ao tecido biológico. / Several studies have shown that elevating the temperature of tumoral tissue improves standard cancer treatments success rate (radiotherapy and chemotherapy). This procedure can also be a therapy to cancer by delivering heat and killing cancer cells while healthy tissues are preserved. For improved efficiency and security in heat applications, it is important to monitor tissue temperature during treatments. Photoacoustic (PA) pressure wave amplitude has a temperature dependence given by the sample mechanical properties (Gruenesein parameter). These changes in photoacoustic signal amplitude carry information about temperature variation in tissue. Therefore, PA has been proposed as an imaging technique to monitor temperature during hyperthermia. In this study, PA images were acquired for temperatures ranging from 36ºC to 41ºC using a tissue-mimicking phantom immersed in a temperature controlled thermal bath. Relative amplitude variation was calculated using speckle tracking algorithms using four different methods to estimate these variations in PA signal amplitude. The results are presented as PA-based thermal images, generated using a calibration factor to the percentage variations in the amplitude maps. Finally, PA-based and ultrasound-based thermal images were acquired during heating by high intensity focused ultrasound (High Intensity Therapeutic Ultrasound - HITU) in a porcine muscle. The results suggest a non-invasive way to monitor temperature during hyperthermia procedures.
23

[en] METROLOGICAL ESTIMATION OF THERMOELECTRIC STABILITY IN AUPT THERMOCOUPLE / [pt] AVALIAÇÃO METROLÓGICA DA ESTABILIDADE TERMOELÉTRICA DE TERMOPAR AUPT

MARCELO DOS SANTOS MONTEIRO 26 June 2003 (has links)
[pt] Em 1990, com a adoção da Escala Internacional de Temperatura de 1990, o termopar de platina e platina/ródio deixou de ser o instrumento de interpolação entre 630 graus Celsius e 1064 graus Celsius, em virtude de sua pouca estabilidade, sendo a partir daí utilizados o termômetro de resistência de platina de alta temperatura (TRPAT) e o termômetro de radiação. Este estudo realiza uma investigação prática das características de um termopar de ouro e platina, ambos com pureza superior a 99,999 por cento, no que diz respeito à sua estabilidade termoelétrica e à homogeneidade de seus termoelementos, questionando a possibilidade de seu uso como alternativa ao emprego do TRPAT em processos de medição que exijam grande exatidão com custo mais baixo. Neste trabalho, o termopar estudado foi submetido a temperaturas próximas ao seu limite máximo de operação, que é de 1000 graus Celsius, por mais de 1500 horas, sendo avaliadas a sua estabilidade e a sua homogeneidade em função do tempo de uso, com o auxílio de uma célula de ponto fixo da prata do Inmetro, que é um padrão primário de temperatura. / [en] In 1990, with the adoption of the International Temperature Scale of 1990, the platinum/platinum-rhodium thermocouple was removed as the interpolation instrument between 630 graus Celsius and 1064 Celsius degrees, due its low stability, in favor of the high temperature standard platinum resistance thermometer (HTSPRT) and the radiation thermometer. In this work, it is performed a practical investigation of the characteristics of a 99,999 percent purity gold-platinum thermocouple, concerning its thermoelectric stability and homogeneity of its thermoelements, questioning the possibility of its use as an alternative to the HTSPRT in measurement processes requiring high accuracy with lower costs. In this work, the test thermocouple was exposed to temperatures close to its upper limit (1000 Celsius degrees) for more than 1500 hours, being its stability and homogeneity evaluated as function of time, with aid of a silver fixed point cell from Inmetro, that is a temperature primary standard.
24

Perfil de citocinas séricas e termografia em equinos quarto de milha submetidos à prova de laço em dupla /

Gerardi, Bianca. January 2016 (has links)
Orientador: Luiz Claudio Nogueira Mendes / Banca: Flávia de Almeida Lucas / Banca:Lina Maria Wehrle Gomide / Banca:Fernanda Bovino / Banca:João Pessoa Araújo Junior / Resumo: Os objetivos do presente estudo foram verificar se existe reação inflamatória no exercício de curta duração e alta intensidade e se a mesma pode ser classificada em Th1, Th2 ou Th17. Além disso, verificar se as temperaturas corpóreas e locais se alteram com exercício este e se treinamentos distintos podem influenciar nestas alterações. Utilizaram-se 12 animais, idade entre 3 e 6 anos e peso médio de 450 kg, participantes de laço em dupla, divididos em: treino regular (GTR) e treino esporádico (GTE). O sangue coletado em tubos de 10 ml sem anticoagulante. Coletas e aferições de temperatura foram realizadas 30 minutos antes, imediatamente depois, uma, duas, seis, e 24 horas após o exercício. Utilizou-se como método de detecção das citocinas a citometria de fluxo. A concentração de IL-10, após uma hora do exercício, foi significativamente maior em GTE do que GTR. Observou-se maior concentração sérica de TNF-, IL-6 e IL-10 entre os grupos, 24 horas após o exercício, mas sem alteração entre os momentos. A temperatura central se restabeleceu dentro de 24 horas. As temperaturas da região dos tendões em membros pélvicos e da garupa mantiveram-se elevadas. O exercício não causou nenhum tipo de resposta imune, animais condicionados, treinados esporadicamente, apresentaram resposta imune mista enquanto que animais condicionados, treinados regularmente, não apresentaram nenhum tipo de resposta imune. O mecanismo de termorregulação foi eficiente em ambos os grupos, o aumento de temperatu... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aims of this study were to verify if there is inflammation in the exercise of short duration and high intensity and whether it can be classified into Th1, Th2 or Th17. Moreover, check the body temperatures and locations change with exercise of short duration and high intensity and different training can influence these changes. 12 animals were used, 6 female and 6 males, mean age 3 to 6 years and weight ∼ 450 kg. Animals were divided in two groups: regular training (GLTR) and sporadic training (GLTE). 10 mL of Blood were collected in tube without anticoagulant. Blood collections and temperatures were made 30 minutes before, immediately after, and one, two, six and 24 hours after competition. The analyses were made by flow cytometric. The serum concentration of IL-10 was significantly higher in GTE than in GTR. The serum concentrations of TNF-, IL-6 and IL-10 were significantly higher in GTE than in GTR, 24 hours after exercise. The core temperature increased after exercise and returned to baseline after 24 hours. The temperature in the region of the hindlimbs raised immediately after exercise and did not return to baseline after 24 hours. The temperature of the croup (right side) increased immediately after exercise and remained so for more than 24 hours. The exercise did not cause any immune response, conditioned animals, trained sporadically showed mixed immune response while conditioned animals, trained regularly, did not show any immune response. The thermoregulatory... (Complete abstract click electronic access below) / Doutor
25

Metodologia de avaliação e de gerenciamento da incerteza de sistemas de medição de temperatura /

Barp, Alexandre Moraes January 2000 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-17T19:51:35Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T19:33:38Z : No. of bitstreams: 1 152982.pdf: 4105265 bytes, checksum: fbc8eb9c523cddcbce41322fe9b213ea (MD5) / O trabalho propõe procedimentos para garantia da confiabilidade metrológica em processos de medição de temperatura. Para tal, ele se baseia no procedimento para gerenciamento da incerteza de medição ("Procedure Uncertainty Management" - PUMA) do relatório técnico ISO/TS 14253-2. Dentro das atividades inerentes ao gerenciamento, maior ênfase é dada à avaliação da incerteza em sistemas automatizados de medição. São apresentadas as principais fontes de incerteza inerentes a transdutores de temperatura com contato e os módulos componentes do sistema de medição necessários para automatizar a medição com tais transdutores. Um ambiente para análise da incerteza seguindo os requisitos do Guia para a Expressão da Incerteza de Medição (ISO-GUM) foi desenvolvido com programas já consagrados. Foi utilizado o programa Excel (Microsoft Co.) para auxíliar no cálculo da incerteza e o programa Pspice (MicroSim Co.) para quantificação das fontes de incerteza individuais.
26

Sistema de monitoramento de temperatura e umidade em silos graneleiros via rádio

Ferrasa, Marcelo [UNESP] 01 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-01Bitstream added on 2014-06-13T19:20:45Z : No. of bitstreams: 1 ferrasa_m_dr_botfca.pdf: 4410782 bytes, checksum: b6c63787a174343b26f5a0ba21755f4b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O uso das Tecnologias da Informação e Comunicação tem crescido nas mais variadas atividades agrícolas. Como conseqüência, vem revolucionando a forma de pensar e agir do produtor que almeja se estabelecer em um mercado cada vez mais competitivo. Entretanto, o alto custo de aquisição e manutenção dessas tecnologias é um fator que pode inibir sua disseminação e aceitação, principalmente a um grande número de pequenos produtores de grãos. Diante desse cenário, há uma necessidade de soluções inovadoras adequadas a esse universo de produtores. Partindo-se dessa premissa, este trabalho apresenta o desenvolvimento de um protótipo de baixo custo para o monitoramento de temperatura e umidade de grãos armazenados em silos, utilizando uma tecnologia de comunicação sem fio por radiofreqüência. Para tanto, foram analisadas as implicações econômicas de custo/benefício do emprego inovador da transmissão sem fio no processo de termometria de grãos. O protótipo foi composto por duas unidades eletrônicas, uma de aquisição e outra de recepção de dados, além de um programa computacional que ofereceu ao produtor informações mais precisas para o controle da aeração. Por meio de testes realizados quanto à estabilidade, integridade e confiabilidade da transmissão de dados via rádio, utilizando componentes eletrônicos de baixo custo, pode-se considerar o sistema desenvolvido potencialmente viável. Este apresentou o diferencial da comunicação sem fio via rádio no processo de termometria de grãos, proporcionando mobilidade, minimizando custos com cabeamento, manutenção e oferecendo facilidades para sua expansão; também adequou-se ao monitoramento de temperatura eumidade de grãos em silos; e mostrou-se com viabilidade operacional, além do baixo custo de desenvolvimento quando comparado a produtos similares encontrados no mercado brasileiro. / The use of Information and Communication Technology has grown in most agricultural activities. As a consequence, it has changed the way of thinking and acting of the farmer who wants to establish in a more and more competitive market. However, the high costs of acquisition and maintenance of those technologies may be a factor which can inhibit its spread and acceptance, mainly to a large number of small grain Brazilian farmers. In this context, there is a need for innovative solution which are proper for this universe of farmers. Starting from this premise, this paper presents the development of a low cost prototype to the monitoring process of temperature and humidity values of grains stored in silos, using communication based on wireless technology by radio frequency. Therefore, the economic implications of cost/benefit ratio of innovative application of wireless transmission in the process of thermometry of grains were analysed. The prototype was made of two electronic units, one of acquisition and another one of data reception, as well as a computational software, which offered the farmer more precise information for the control of aeration. By means of stability, integrity and reliability tests of data transmission via radio, using low cost electronic components, the development system can be considered as potentially viable. It presented the difference regarding the wireless communication via radio in the process of grains thermometry, providing mobility, reducing cabling costs and maintenance, and also offering an easy system expansion; it was also appropriate to temperature and humidity monitoring in grain silos; and revealed operational viability, besides 4 the low cost development when compared to similar products available in the Brazilian market.
27

Uso da termometria de infravermelho na predição de tolerância ao calor em trigo em dois ambientes de cultivo / Use of infrared thermometry and the evaluation of agronomic traits in wheat cultivar heat tolerance prediction

Tobar, Laura Maritza Saavedra 03 December 2013 (has links)
Made available in DSpace on 2015-03-26T13:40:01Z (GMT). No. of bitstreams: 1 texto completo.pdf: 716927 bytes, checksum: 2d7eff1a3130da5b28fc4573144a70c4 (MD5) Previous issue date: 2013-12-03 / Even though wheat is originated from cold climates, the use of adapted cultivars allows its production in regions with tropical climates, but high temperatures during the crop cycle may become one of the main factors that cause abiotic stress, limiting the well development of the plant and, consequently, a drastic decline in the productivity potential. The wheat production in the central region of Brazil is observed to have been affected because of the increases in temperature which are presented during the different phenological stages, becoming alike to the main limiting factor to its full development. The knowledge of methodologies that are easy to access and are of practical use, which are efficient for plant selection in field conditions is indispensable for the recognition and obtainment of cultivars with tolerance to heat. The objective of this work was to Evaluate canopy temperature depression through the use of infrared thermometry and agronomic traits in wheat cultivars, sown in pots with soil in through conventional cultivation with the intent to compare cultivar reaction to each environment, aiming to confirm which of these present tolerance to heat stress.The experiment was conducted at the Experimental Station Professor Diogo Alves de Melo - of the Federal University of Viçosa (UFV), Viçosa-MG. A completely randomized design was utilized. Six cultivars are utilized for use in the central region of Brazil: Aliança, Anahuac, Embrapa 22, BRS 254, BRS 264 and BRS 207. The cultivars were sown towards the end of July with varying temperatures throughout the development of the plant. There were no significant differences between cultivars when comparing the decline in the temperature of the evaluated plant organs. Only local effects were existent, which was attributed to the fact that, during the general culture development the average air temperature didn't reach values that are considered stressful, being found between 18 and 21° which is considered an C, ideal temperature range for wheat culture. The occurrence of winds may have reduced the canopy temperature of the plants sown in pots, which made these present higher temperature decline values when compared to plants cultivated in the environment's soil. Most of the agronomic traits evaluated present significant differences between environments and between cultivars, being that the pots' environment had the highest average values except for the harvesting index and the weight of one thousand grains, which were bigger in the conventional cultivation. / Mesmo o trigo sendo originário de climas frios, o uso de cultivares adaptadas possibilita sua produção em regiões de climas tropicais, mas as altas temperaturas durante seu ciclo podem tornar um dos principais estresses abióticos, limitando seu bom desenvolvimento e, consequentemente, levando a diminuição drástica no potencial produtivo. A produção de trigo na região central do Brasil é afetada devido aos incrementos da temperatura que se apresentam durante os diferentes estados fenológicos da planta. Deste modo, o conhecimento de metodologias de acesso fácil e de uso prático, que sejam eficientes para a seleção de plantas em condições de campo é imprescindível para a identificação e a obtenção de cultivares com tolerância ao calor. O objetivo deste trabalho foi Avaliar a depressão da temperatura do dossel por meio do método da termometria infravermelha e caracteres agronômicos em cultivares de trigo, semeadas em vasos com solo e em cultivo convencional a fim de comparar o comportamento das cultivares nos dois ambientes, visando qual destas apresentam tolerância ao estresse de calor. O experimento foi conduzido na Estação Experimental Prof. Diogo Alves de Melo da Universidade Federal de Viçosa (UFV), Viçosa-MG. Utilizou-se o delineamento experimental inteiramente casualizado. As cultivares avaliadas foram: Aliança, Anahuac, Embrapa 22, BRS 254, BRS 264 e BRS 207, sendo semeadas no final do mês junho com temperaturas variáveis ao longo do desenvolvimento das plantas. A depressão da temperatura no dossel não apresentou diferenças entre as cultivares. O efeito apresentado foi de local, o que foi atribuído ao fato de que, durante o desenvolvimento das plantas o ambiente não apresentou estresse acentuado pelo calor, considerando que a temperatura média do ar encontrava-se numa faixa entre 18 a 21° considerada adequada para o desenvolvimento da cultura de C, trigo. A ocorrência de ventos possivelmente reduziu a temperatura no dossel das plantas cultivadas em vasos, fazendo com que estas apresentassem maiores valores de depressão de temperatura em comparação com as plantas cultivadas no solo. Para a maioria dos caracteres agronômicos avaliados houve diferença significativa entre ambientes e entre cultivares, apresentando-se o ambiente nos vasos com maiores valores de médias, exceto o índice de colheita e massa de mil grãos que foram maiores no cultivo convencional.
28

Perfil de citocinas séricas e termografia em equinos quarto de milha submetidos à prova de laço em dupla / Profile of serum cytokines and thermography in quarter horses subjected to team roping

Gerardi, Bianca [UNESP] 25 July 2016 (has links)
Submitted by Bianca Gerardi null (bi_gerardi@hotmail.com) on 2016-08-04T00:47:26Z No. of bitstreams: 1 Perfil de citocinas séricas e termografia em equinos quarto de milha submetidos à prova de laço em dupla - Bianca Gerardi.pdf: 1625786 bytes, checksum: 2e6e055878a273e0a82f20dbda6fefe2 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-09T13:38:34Z (GMT) No. of bitstreams: 1 gerardi_b_dr_araca.pdf: 1625786 bytes, checksum: 2e6e055878a273e0a82f20dbda6fefe2 (MD5) / Made available in DSpace on 2016-08-09T13:38:34Z (GMT). No. of bitstreams: 1 gerardi_b_dr_araca.pdf: 1625786 bytes, checksum: 2e6e055878a273e0a82f20dbda6fefe2 (MD5) Previous issue date: 2016-07-25 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Os objetivos do presente estudo foram verificar se existe reação inflamatória no exercício de curta duração e alta intensidade e se a mesma pode ser classificada em Th1, Th2 ou Th17. Além disso, verificar se as temperaturas corpóreas e locais se alteram com exercício este e se treinamentos distintos podem influenciar nestas alterações. Utilizaram-se 12 animais, idade entre 3 e 6 anos e peso médio de 450 kg, participantes de laço em dupla, divididos em: treino regular (GTR) e treino esporádico (GTE). O sangue coletado em tubos de 10 ml sem anticoagulante. Coletas e aferições de temperatura foram realizadas 30 minutos antes, imediatamente depois, uma, duas, seis, e 24 horas após o exercício. Utilizou-se como método de detecção das citocinas a citometria de fluxo. A concentração de IL-10, após uma hora do exercício, foi significativamente maior em GTE do que GTR. Observou-se maior concentração sérica de TNF-, IL-6 e IL-10 entre os grupos, 24 horas após o exercício, mas sem alteração entre os momentos. A temperatura central se restabeleceu dentro de 24 horas. As temperaturas da região dos tendões em membros pélvicos e da garupa mantiveram-se elevadas. O exercício não causou nenhum tipo de resposta imune, animais condicionados, treinados esporadicamente, apresentaram resposta imune mista enquanto que animais condicionados, treinados regularmente, não apresentaram nenhum tipo de resposta imune. O mecanismo de termorregulação foi eficiente em ambos os grupos, o aumento de temperatura local após 24 horas pode ser infleuenciado pela temperatura ambiente ou ser sugestivo de inflamação subclínica. / The aims of this study were to verify if there is inflammation in the exercise of short duration and high intensity and whether it can be classified into Th1, Th2 or Th17. Moreover, check the body temperatures and locations change with exercise of short duration and high intensity and different training can influence these changes. 12 animals were used, 6 female and 6 males, mean age 3 to 6 years and weight ∼ 450 kg. Animals were divided in two groups: regular training (GLTR) and sporadic training (GLTE). 10 mL of Blood were collected in tube without anticoagulant. Blood collections and temperatures were made 30 minutes before, immediately after, and one, two, six and 24 hours after competition. The analyses were made by flow cytometric. The serum concentration of IL-10 was significantly higher in GTE than in GTR. The serum concentrations of TNF-, IL-6 and IL-10 were significantly higher in GTE than in GTR, 24 hours after exercise. The core temperature increased after exercise and returned to baseline after 24 hours. The temperature in the region of the hindlimbs raised immediately after exercise and did not return to baseline after 24 hours. The temperature of the croup (right side) increased immediately after exercise and remained so for more than 24 hours. The exercise did not cause any immune response, conditioned animals, trained sporadically showed mixed immune response while conditioned animals, trained regularly, did not show any immune response. The thermoregulatory mechanism was efficient in both groups, the local temperature increase after 24 hours due to room temperature or suggestive of subclinical inflammation. / FAPESP: 2014/09362-5
29

Avaliação da ação anti-inflamatória da semente de sucupira branca (Pterodon emarginatus, Vogel), utilizando cães portadores de doenças inflamatórias da articulação coxofemural diagnosticado pela tomografia infravermelha

FUKAHORI, Fernanda Lúcia Passos 16 February 2017 (has links)
Submitted by Mario BC (mario@bc.ufrpe.br) on 2018-02-23T12:52:23Z No. of bitstreams: 1 Fenanda Lucia Passos Fukahori.pdf: 1391699 bytes, checksum: f829980f477d48fffc2d9c919805108e (MD5) / Made available in DSpace on 2018-02-23T12:52:23Z (GMT). No. of bitstreams: 1 Fenanda Lucia Passos Fukahori.pdf: 1391699 bytes, checksum: f829980f477d48fffc2d9c919805108e (MD5) Previous issue date: 2017-02-16 / The objective of this study was to standardize a method for the diagnosis of inflammatory foci using infrared thermometry in healthy dogs and dogs that exhibit clinical signs of inflammation in the coxofemoral joint and to investigate the anti-inflammatory effect of Sucupira seed in dogs with inflammatory diseases of the coxofemoral joint. For the standardization of the use of the thermograph, 31 dogs, adults, of different races from the outpatient clinic of the UFRPE. All animals were referred to an air-conditioned room at 25 ° C, relative air humidity above 70%, where after a period of 20min the rectal temperature was recorded using a conventional clinical thermometer and the temperature on the axis of the Articulation in anteroposterior and lateral plugs by a digital thermograph for capturing electromagnetic waves in the infrared spectral band model TG165 from Flir Systems. In this work, in order to minimize the external interferences on the reading of the equipment, a PVC cannula coated with frosted black paint, with a length of 30cm was coupled to the equipment outlet. At the time of recording the temperature readings, the cannula and the equipment were juxtaposed over the desired region, after adequate positioning of the animal in each record. The focus, under these conditions, was equivalent to an area of 1.23cm2. The emissivity of the equipment was adjusted to e = 0.95 in all measurements. From a total of 31 animals evaluated, all previously submitted to a clinical evaluation, there was a significant difference between the normalized joint temperature values found for the groups of animals with inflammation in relation to the animals without articular disease, showing sensitivity of 80, 0%, specificity of 87.5% and method accuracy of 83.87%. In order to obtain the sucupira seed extract, it was prepared in preparations with Biotônico Fontoura in the proportion of 15% (m / v), generating an extract that was applied in the dose and 300 mg / kg (vo) in animals clinically positive for inflammation in the joint Hip. At times of t = 0, t = 10 days and t = 21 days, the body temperature and the temperature on the joint were measured in the lateral dimension (thermography), defining the FT factor as a parameter to measure the thermal transformations on the inflammation. As a result, it was verified that in sucupira-treated animals, significant changes occurred in the FT factor, denoting the positive effect of the extract on the containment of the inflammatory process associated with the inflammation on the joint. Animals treated with meloxican (0.1mg / kg) did not present significant variations of the FT factor, showing little effect on the inflammatory process. The rate of infinitesimal FT variation in animals treated with sucupira extract was 61% more effective than FT obtained for animals treated with meloxican. No significant changes in biochemical parameters, blood count and leukogram were observed in blood samples obtained after 21 days of treatment with sucupira extract. / Este trabalho teve como objetivo de propor a padronização de um método para o diagnóstico de focos inflamatórios, mediante o emprego da termometria por infravermelho, em cães sadios e cães que exibem sinais clínicos de inflamação na articulação coxofemoral e de investigar a o efeito anti-inflamatório da semente de sucupira em cães portadores de doenças de ordem inflamatória da articulação coxofemoral. Para a padronização da utilização do termógrafo foram avaliados 31 cães, adultos, de diferentes raças provenientes do ambulatório do HV da UFRPE. Todos os animais foram encaminhados para uma sala climatizada a 25°C, umidade relativa do ar acima de 70%, onde após um período de 20min era efetuado o registro da temperatura retal, mediante uso de termômetro clínico convencional e da temperatura sobre o eixo da articulação coxofemoral em tomadas anteroposterior e lateral por um termógrafo digital de captura de ondas eletromagnéticas na faixa espectral do infravermelho modelo TG165 da Flir Systems. Neste trabalho, afim de que fossem minimizadas as interferências externas sobre a leitura do equipamento, foi acoplado à saída do equipamento uma cânula de PVC revestida com película tinta preto fosco, com 30cm de comprimento. No momento do registro das leituras de temperatura, a cânula e o equipamento eram justapostos sobre a região desejada, após posicionamento adequado do animal em cada registro. O foco, nestas condições foi equivalente à uma área de 1,23cm2. A emissividade do equipamento foi ajustada para e = 0,95 , em todas aferições. De um total de 31 animais avaliados, todos submetidos previamente à uma avaliação clínica, verificou-se diferença significativa entre os valores normalizados da temperatura da articulação encontrados para os grupos de animais com inflamação em relação aos animais sem doença articular, apresentando sensibilidade de 80,0%, especificidade de 87,5% e precisão do método de 83,87%. Para a obtenção do extrato de semente de sucupira foi confeccionado em preparações com Biotônico Fontoura na proporção de 15% (m/v), gerando um extrato que foi aplicado na dose e 300mg/Kg (v.o.) em animais clinicamente positivo para inflamação na articulação coxofemoral. Nos tempos de t=0, t=10dias e t=21dias, tomadas de temperatura corpórea (termômetro clínico) e temperatura sobre a articulação na dimensão lateral (termografia), definindo-se o fator FT, como parâmetro para dimensionar as transformações térmicas sobre a inflamação. Como resultado verificou-se que em animais tratados com sucupira, ocorreram transformações significativas no fator FT denunciando efeito positivo do extrato na contenção de processo inflamatório associado à inflamação sobre a articulação. Animais tratados com meloxican (0,1mg/Kg), não apresentaram variações significativas do fator FT, apresentando pouco efeito sobre o processo inflamatório. A taxa de variação infinitesimal de FT em animais tratados com extrato de sucupira foi 61% mais eficaz do que FT obtido para animais tratados com meloxican. Não foram observadas alterações significativas nos parâmetros bioquímicos, no hemograma e leucograma em amostras de sangue obtidas após 21 dias de tratamento com extrato de sucupira.
30

Monitoramento de temperatura tecidual por meio de imagens fotoacústicas durante tratamento de hipetermia / Tecidual temperature monitoring using photoacoustic images during hyperthermia treatments.

João Henrique Uliana 29 September 2016 (has links)
Sabe-se que o aumento na temperatura do tecido tumoral pode aumentar a eficiência de técnicas convencionais de combate ao câncer (radioterapia e quimioterapia). Além disso, a variação de temperatura em tumores pode ser uma forma de tratamento alternativo à cirurgia, feito por meio do fornecimento de calor direcionado às células cancerosas e preservando o tecido sadio. Para maior eficácia e segurança no emprego de técnicas que utilizam fornecimento de calor ao tecido biológico, é necessário o monitoramento da temperatura tecidual para garantir que a morte celular por ablação térmica seja limitada ao tecido alvo, minimizando os danos aos tecidos adjacentes. A imagem fotoacústica é uma técnica baseada no efeito fotoacústico, o qual consiste na absorção de radiação eletromagnética pelo tecido e, devido à expansão termoelástica, na geração de ondas acústicas. A amplitude da onda de pressão gerada pelo efeito fotoacústico possui dependência com a temperatura do meio pelo parâmetro de Grueneisen, que depende das propriedades mecânicas do material. Portanto, mudanças na amplitude do sinal fotoacústico carregam informações a respeito da variação na temperatura do material. Neste trabalho, a dependência da amplitude do sinal fotoacústico com a temperatura foi estudada em um material simulador de tecido biológico (phantom) em condições similares a de tratamentos por hipertermia Nesse caso, imagens fotoacústicas foram adquiridas para cada grau de temperatura em uma faixa de 36 até 41 ºC durante o procedimento de aquecimento por banho térmico. Mudanças na amplitude e fase do sinal fotoacústico foram avaliadas através da aplicação de algoritmos de speckle tracking. Para estimar a variação na amplitude do sinal também foram utilizados e avaliados diferentes métodos de comparação. Os resultados são apresentados por imagens fotoacústicas termais produzidas pela aplicação de um fator de calibração aos mapas de variação relativa da amplitude do sinal em função da temperatura do meio. Finalmente, avaliamos um experimento de hipertemia por ultrassom focalizado de alta intensidade (High Intensity Therapeutic Ultrasound - HITU) em uma amostra de músculo suíno. Nesse caso foram geradas imagens termais fotoacústicas e imagens termais produzidas pela mudança de fase do sinal pulso-eco de ultrassom. Os resultados sugerem uma maneira não invasiva de calcular a distribuição da variação de temperatura do meio que pode ser aplicada para monitoramento durante tratamentos que utilizam o fornecimento de calor ao tecido biológico. / Several studies have shown that elevating the temperature of tumoral tissue improves standard cancer treatments success rate (radiotherapy and chemotherapy). This procedure can also be a therapy to cancer by delivering heat and killing cancer cells while healthy tissues are preserved. For improved efficiency and security in heat applications, it is important to monitor tissue temperature during treatments. Photoacoustic (PA) pressure wave amplitude has a temperature dependence given by the sample mechanical properties (Gruenesein parameter). These changes in photoacoustic signal amplitude carry information about temperature variation in tissue. Therefore, PA has been proposed as an imaging technique to monitor temperature during hyperthermia. In this study, PA images were acquired for temperatures ranging from 36ºC to 41ºC using a tissue-mimicking phantom immersed in a temperature controlled thermal bath. Relative amplitude variation was calculated using speckle tracking algorithms using four different methods to estimate these variations in PA signal amplitude. The results are presented as PA-based thermal images, generated using a calibration factor to the percentage variations in the amplitude maps. Finally, PA-based and ultrasound-based thermal images were acquired during heating by high intensity focused ultrasound (High Intensity Therapeutic Ultrasound - HITU) in a porcine muscle. The results suggest a non-invasive way to monitor temperature during hyperthermia procedures.

Page generated in 0.0786 seconds