• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 307
  • 105
  • 34
  • 21
  • 18
  • 10
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 579
  • 579
  • 315
  • 294
  • 125
  • 88
  • 78
  • 76
  • 68
  • 67
  • 64
  • 62
  • 59
  • 58
  • 53
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Ventilação natural em edifícios de escritórios na cidade de São Paulo: limites e possibilidades do ponto de vista do conforto térmico / Natural ventilation in São Paulo office buildings: thermal comfort limits and possibilities

Figueiredo, Cíntia Mara de 10 April 2007 (has links)
Esta pesquisa avalia o potencial de utilização da ventilação natural em edifícios de escritórios na cidade de São Paulo do ponto de vista do conforto térmico. Como parte do trabalho, foi elaborado um modelo de um edifício de escritórios com características arquitetônicas e de ocupação semelhantes às existentes nestes edifícios atualmente em São Paulo. A pesquisa foi feita com simulações computacionais deste modelo. Primeiramente foram avaliadas as temperaturas internas. Uma área do modelo foi simulada no software EnergyPlus para as oito orientações solares principais, com objetivo de se estimar as temperaturas operativas médias horárias para todos os meses do ano. Os resultados foram analisados sob o enfoque da teoria adaptativa de conforto térmico, de acordo com o índice para ambientes ventilados naturalmente proposto pela norma Ashrae 55, 2004. Esta análise gerou o mapeamento dos períodos do ano onde o ambiente estaria confortável se forem considerados 90% ou 80% de usuários satisfeitos e quanto não estaria confortável, tanto por calor quanto por frio. Também foi feita uma avaliação do modelo, de caráter exploratório, com simulações em um software de dinâmica dos fluidos, o CFX. Estas simulações objetivaram estimar se a estratificação da temperatura ou as velocidades internas do ar poderiam gerar áreas localizadas de desconforto no ambiente. / This research evaluates the potential for the use of natural ventilation in São Paulo city office buildings from a thermal comfort viewpoint. As part of the work, a model was developed with architectural and occupational characteristics similar to the those of office buildings in São Paulo city. The research was carried out using computational simulations of this model. First internal temperatures were evaluated. An area of the model was simulated in EnergyPlus software for the eight main solar orientations, with the object of estimating the average operative temperature for all months of the year. The results were analyzed under the focus of the adaptive thermal comfort theory, according the index proposed in Ashrae Standard 55, 2004 for naturally ventilated environments. This analysis generated a mapping of the annual periods where this space would be comfortable for 90% or 80% satisfied users and when it would not be comfortable, either for warmth or for cold. An exploratory study of that model was done, using computational fluid dynamics with CFX software. The objective was to estimate if the temperature stratification and the internal air velocities could cause local areas of discomfort within this environment.
82

Análise experimental da influência do sistema de ventilação e distribuição de ar no conforto térmico e na dispersão e remoção de partí­culas expiratórias em cabine de aeronave. / Experimental analysis of the influence of the ventilation and air distribution system in the thermal comfort and in the dispersion and removal of expiratory particles in the aircraft cabin.

Fabichak Junior, Douglas 21 September 2018 (has links)
O conforto térmico e a dispersão e remoção de partículas em cabine de aeronave são função, fundamentalmente, do seu sistema de ventilação e distribuição de ar. Juntamente com a análise da influência do sistema de ventilação por mistura (MV), atualmente utilizado em aviões comerciais, no presente trabalho são propostos e analisados dois novos sistemas, o sistema de distribuição de ar pelo piso (UFAD) e o sistema de ventilação por deslocamento (DV). A análise experimental de condições de desconforto térmico local e de dispersão e remoção de partículas expiratórias foi realizada em um mock-up de uma aeronave comercial com 12 assentos, com 4 assentos por fileira. Os resultados mostram forte influência da temperatura do ar insuflado na cabine, de 18 °C e 22 °C, do ponto de geração de partículas na cabine, em assento junto à fuselagem e junto ao corredor, e da faixa de tamanhos de partículas, principalmente nas faixas de 2,0 a 3,0 µm e de 3,0 a 5,0 µm, de maior interesse no presente trabalho. Por fim, os resultados mostram que o sistema UFAD apresentou o melhor desempenho, tanto quanto ao desconforto térmico devido a correntes de ar, com valores abaixo de 20 % preconizado pelas normas ISO 7730 (2005) e ASHRAE 55 (2013), quanto à menor dispersão de partículas e maior eficiência na remoção de partículas na região de respiração, com eficiência na remoção de partículas maior em até 18,8 % em relação ao sistema DV e em até 41,6 % em relação ao sistema MV. O sistema DV apresentou resultados intermediários com relação ao desconforto térmico local, com pior resultado na região dos pés com média do desconforto térmico local de 22,7 % e muito boa eficiência na remoção de partículas em relação ao sistema convencional MV maior em até 32,0 %. O sistema MV apresentou as piores condições com relação ao desconforto térmico para a região da cabeça e dos pés, com média de pessoas insatisfeitas de até 25,7 %. O sistema MV também apresentou as piores condições com relação à eficiência de remoção de partículas com a maior quantidade total de partículas na região de respiração ao longo da aeronave. / Thermal comfort and particles dispersion and removal in an aircraft cabin depend, essentially, on its ventilation and air distribution system. Together with the analysis of the influence of the mixing ventilation system (MV), used in commercial aircrafts, in the present work two new systems are proposed and analyzed, the underfloor air distribution system (UFAD) and the displacement ventilation system (DV). Experimental analysis of local thermal discomfort conditions and dispersion and removal of expiratory particles was performed in a mock-up of a commercial 12 seat aircraft with 4 seats per row. The results show a strong influence of the temperature ot the air inflated into the cabin, of 18°C and 22°C, of the point of generation of particles in the cabin, at the seat next to the fuselage and near the corridor, and of the particle size range, mainly in the bands of 2.0 to 3.0 µm and 3.0 to 5.0 µm, of greater interest in the present study. Finally, the results show that the UFAD system presented the best performance, as well as the thermal discomfort due to drafts, with values below 20% recommended by ISO 7730 (2005) and ASHRAE 55 (2013), as well as the lower dispersion of particles and greater efficiency in the removal of particles in the respiratory region, with particle removal 18.8% in relation to the DV system and by up to 41.6% in relation to the MV system. The DV system presented intermediate results in relation to the local thermal discomfort, with worse results in the feet region with a mean of the local thermal discomfort of 22.7% and very good particle removal efficiency in relation to the conventional MV system of up to 32, 0%. The MV system presented the worst conditions in relation to the thermal discomfort for the head and feet region, with an unsatisfied average of up to 25.7%. The MV system also presented the worst conditions with respect to the removal efficiency of particles with the highest total amount of particles in the breathing region along the aircraft.
83

Galpão freestall com sistema de resfriamento evaporativo e ventilação cruzada: desempenho térmico, zootécnico e o nível de bem estar animal / Low-Profile Cross-Ventilated freestall: thermal, zootechnical and animal welfare performance

Garcia, Paulo Rogério 18 September 2017 (has links)
O confinamento de bovinos leiteiros de alto padrão genético em instalações climatizadas do tipo freestall é uma das principais alternativas adotadas pelos produtores com a finalidade de mitigar os efeitos do estresse térmico. Neste cenário, o galpão freestall de laterais fechadas com sistema de resfriamento evaporativo e ventilação cruzada, em inglês low-profile cross-ventilated freestall (LPCV), é um novo conceito no sistema de produção de leite. Não há muita informação na literatura científica sobre o uso desta tipologia para confinamento de vacas holandesas em região de clima quente e úmido, caso o Brasil. Portanto, o objetivo desse estudo foi avaliar o desempenho térmico (temperatura, umidade, velocidade do vento, indexes de conforto térmico, nível de ruído e de iluminância), zootécnico (produtividade, número de intervenções veterinárias para mastite e retenção de placenta, período de serviço, intervalo entre partos e taxa de prenhez) e o nível de bem-estar animal (limpeza corporal, lesões de jarrete, claudicação, taxa respiratória e descarga nasal) proporcionado por um galpão LPCV, para alojamento de vacas holandesas lactantes, em comparação a um galpão freestall convencional, em que a ventilação natural esta associada ao uso de ventiladores e aspersores (FVA). Verificou-se que o LPCV promoveu um maior controle do microclima interno, registrando menores amplitudes térmicas e maior redução do tempo de exposição dos animais a condições térmicas estressantes, comparado ao galpão FVA. As variáveis apresentaram uma dispersão gradiente no sentido transversal do galpão LPCV, porém a amplitude desta variação espacial foi baixa. Além disso, os animais apresentaram um adequado nível de bem-estar animal, e houve uma melhora nos índices zootécnicos da propriedade. Desse modo, conclui-se que a utilização do galpão freestall fechado com sistema de resfriamento evaporativo e ventilação cruzada foi mais eficiente que o galpão freestall convencional para confinamento de vacas holandesas em lactação, nas condições ambientais estudadas, considerando os aspectos referentes ao controle das variáveis físicas do ambiente interno, os aspectos zootécnicos e de bem-estar animal. / The Holstein dairy cattle breeding in the freestall facilities is one of the alternatives adopted by producers in order to reduce the effect of heat stress. In this scenario, low-profile cross-ventilated freestall (LPCV) is a new concept in milk production system. There is not much information in the scientific literature about the use of this typology for confining Holstein cows in a hot and humid climate region, such as Brazil. Therefore, the aim of this study was to evaluate the thermal (temperature, humidity, air velocity, thermal comfort indexes, noise level and luminosity), zootechnical (productivity, number of veterinary interventions for mastitis and retention of placenta, open days, pregnancy interval and rate) and the level of animal welfare (cleanliness of animals, hock injuries, lameness, respiratory rate, nasal discharge) provided by a LPCV barn comparing to a conventional freestall barn where natural ventilation is associated with the use of fans and sprinklers (FVA). It was verified that the LPCV promoted a greater control of the internal microclimate, registering lower thermal amplitudes and greater reduction of exposure time of the animals to stressful thermal conditions, compared to the FVA. The variables presented a gradient dispersion in the transverse direction of the LPCV barn, but the amplitude of this spatial variation was low. In addition, the animals presented an adequate level of animal welfare, and there was an improvement in the zootechnical indexes of the property. Thus, it was concluded that the use of the full-closed freestall barn with evaporative panel and cross-ventilation was more efficient than the conventional freestall for confinement of lactating Holstein cows under the environmental conditions studied, considering the aspects regarding the control of physical variables in the internal environment, zootechnical aspects and animal welfare.
84

O conforto térmico nas residências de Rino Levi / The thermal comfort in the residences of Rino Levi

Rahal, Marina Silva 05 May 2006 (has links)
Esta pesquisa avalia o conforto térmico das residências projetadas pelo arquiteto Rino Levi, um dos protagonistas da arquitetura moderna brasileira, que se caracterizam pela presença de jardins integrados aos ambientes internos. As sete obras residenciais estudadas localizam-se em regiões diferentes do território brasileiro e apresentam soluções para o condicionamento térmico de acordo com as exigências climáticas do local, tais como elementos de proteção solar, dispositivos para ventilação cruzada ou instalação de calefação. O objetivo deste trabalho é identificar e analisar as soluções arquitetônicas desenvolvidas para garantir o conforto térmico nestas residências. A análise é feita a partir das recomendações construtivas referentes à insolação e ventilação, elaboradas na mesma época em que as casas foram projetadas, e complementada pelas diretrizes construtivas indicadas na norma brasileira atual de desempenho térmico. Verifica-se que a maior parte das soluções projetuais desenvolvidas por Rino Levi para estas casas estão de acordo com as recomendações construtivas da época, bem como as atuais, no tocante ao conforto térmico / This research evaluates the thermal comfort of the residences projected by Rino Levi, one of the Brazilian modern architecture’s protagonists. These houses are characterized by the presence of gardens integrated with the internal spaces. The seven residences studied are located in different regions of Brazilian territory, and present different solutions for thermal performance, according to the exigencies of local climate, like shading elements, crossing ventilations devices or calefaction. This work intends to identify the architectural solutions developed to guarantee thermal comfort in these residences. The analysis is made based on constructive recommendations about solar radiation and ventilation elaborated when these houses were projected and the constructive directress indicated by actual Brazilian norm about thermal performance. The efficiency of most of constructive solution developed by Rino Levi for these residences concerning thermal comfort is verified
85

Análise numérica da influência de configurações de aberturas da fachada e do mobiliário na ventilação natural em ambientes de escritórios. / Numerical analysis of the influence of facade openings and furniture configurations on natural ventilation in office environments.

Mariana, Flávio Bomfim 19 April 2013 (has links)
Com a disseminação do conceito de desenvolvimento sustentável tem sido verificado um aumento no interesse por sistemas de baixo ou nenhum consumo de energia. Uma forma de diminuir o consumo e propiciar condições de qualidade do ar e conforto térmico é utilizar a ventilação natural. No presente trabalho analisa-se a influência de diferentes tipos de janelas e mobiliário sobre as condições de ventilação natural em ambientes de escritório utilizando simulação numérica. O modelo é composto por um edifício de cinco pavimentos, sendo analisadas as condições térmicas do pavimento mais alto. A mudança do mobiliário apresentou tendência de piora das condições de conforto com o aumento das partições, sendo significativa com partições de 1,50m de altura e as demais condições menos propícias para a ventilação natural. Não foi observada mudança significativa entre as partições de 0,90m e 1,10m, sendo preferível então a última pela melhor privacidade dos ocupantes. A modificação do layout não resultou em mudanças significativas de temperatura do ar no ambiente ocupado, salvo na configuração que reuniu as piores condições de ventilação. Já a geometria das janelas apresentou resultados significativamente diferentes, pois a janela maxim-ar permitiu a entrada de um volume maior de ar e o distribuiu melhor dentro dos ambientes de escritório simulados, em comparação com a janela de correr vertical. Verificou-se que a escolha adequada das janelas influencia o ambiente térmico de maneira semelhante à redução da iluminação e dos equipamentos que dissipam calor. Concluiu-se que com a implantação adequada da edificação, escolha correta das aberturas, da configuração do mobiliário e das cargas térmicas internas é possível utilizar sistemas de ventilação natural em ambientes de escritórios com bons resultados. Por fim, é importante destacar que a aplicação da dinâmica dos fluidos computacional (CFD) para ventilação natural é complexa, pois este fenômeno é naturalmente instável, com necessidade de bastante cuidado na definição dos modelos para representar o problema e no processo de simulação numérica. / Among the spread of the sustainability concept it has been found a rising interest on low or zero energy consumption systems. One approach to reduce energy consumption and also provide acceptable levels of indoor air quality and thermal comfort is using natural ventilation. On the present report it is analyzed the influence of different types of windows and furniture on natural ventilation conditions of office environments using numerical simulation. The model is a five storey building, being the thermal conditions evaluated in the highest floor. Furniture change presented a worsen tendency of the comfort conditions as the partitions height increased. This worsen was significant when 1.50m height partitions were combined with other features less propitious for natural ventilation. No significant change was found between the 0.90m and 1.10m height partitions, being the last preferable due to occupants privacy enhance. Layout modification did not result on significant changes of occupied zone air temperature, except on the set up that gathered the worse ventilation conditions. However, the different window geometries presented results significantly different, since the maxim-air window allowed the entrance of more wind and has distributed it better inside the simulated office environments. Therefore, thermal comfort conditions became better than in comparison with the vertical sliding windows. It was verified that the adequate choice of windows influences the thermal environment in a similar way to the reduction of lighting and equipments that dissipate heat. It was concluded that with the proper building implementation, correct choice of openings, furniture configuration and internal heat gains it is possible to use natural ventilation in office environments with good results. Finally, it is noteworthy the complexity in applying the computational fluid dynamics (CFD) for natural ventilation, since it is an inherently unstable phenomenon, requiring considerable care in defining the models to represent the problem and in the numerical simulation process.
86

Desempenho térmico e visual de elementos transparentes frente à radiação solar / Thermal and visual performance of transparent elements related to the solar radiation

Santos, Joaquim Cesar Pizzutti dos 23 August 2002 (has links)
A especificação das vedações transparentes é uma das decisões mais complexas no âmbito do projeto arquitetônico. Envolve diversos fatores construtivos e de necessidades humanas relacionadas ao conforto ambiental, associadas a uma grande variedade de produtos disponíveis no mercado. Este trabalho busca facilitar aos projetistas esse processo de especificação, fornecendo valores dos parâmetros de desempenho dos elementos transparentes em relação à análise do conforto térmico e visual, coerentes com a realidade climática brasileira e com a real incidência da radiação solar ao longo do dia. Foram estudados os vidros comuns, laminados e refletivos, e as películas de controle solar, policarbonatos e acrílicos usados em edificações no Brasil. Foi utilizada a análise por espectrofotometria para a obtenção dos valores de refletância, transmitância a absortância para as diferentes regiões do espectro solar, com ângulos de incidência variados. A partir do relacionamento desses resultados, considerando o comportamento similar de variação do Fator do Calor Solar (FCS) e da Transmitância da Luz Visível (Tv) com o ângulo de incidência, foi desenvolvida uma metodologia que possibilita o cálculo simplificado de ganhos de calor e luz natural. / The specification of the transparent elements is one of the most complex decisions in the ambit of the architectural project. It involves several constructive factors and human necessities related to the environmental comfort, associated to a great variety of available products in the market. The aim of this work is to facilitate the specification process to the planners, supplying values of the performance parameters of the transparent elements in relation to the analysis of thermal and visual comfort, coherent with the Brazilian climatic reality and with real incidence of the solar radiation along of the day. It were studied the ordinary, laminate and reflective glasses, the solar control films, policarbonates and acrylic used in Brazilian constructions. The spectrophotometry analysis was used to obtain the reflectance, the transmittance and the absortance values for the different regions of the solar spectrum, with varied incidence angles. Starting from the relationship of those results, considering the similar behavior of variation of the Solar Heat Factor (FCS) and of Transmittance of the Visible Light (Tv) with the incidence angle, it was developed a methodology that facilitates the simplified calculation of heat and natural light gains.
87

LEVANTAMENTO DA VEGETAÇÃO ARBÓREA E AVALIAÇÃO DO CONFORTO TÉRMICO DAS CINCO ESPÉCIES DE MAIOR INCIDÊNCIA, NA CIDADE DE URUAÇU, GOIÁS.

Malentachi, Iversen Fernandez 20 August 2013 (has links)
Made available in DSpace on 2016-08-10T10:44:42Z (GMT). No. of bitstreams: 1 IVERSEN FERNANDEZ MALENTACHI.pdf: 4235035 bytes, checksum: e4f5e8e3fdc2521283878c987800b12e (MD5) Previous issue date: 2013-08-20 / Or urban forestry, aims at improving the quality of life of urban populations, as they face several problems related to urbanization. The urban forestry models used in the cities of Goiás are mostly of the monoculture type, which may lead to the ineffectiveness of its goals. In order to undergo a more thorough assessment of urban forestry, this research work was developed in the city of Uruaçu, Goiás, and it aimed at quantifying and qualifying the species of trees available in the city. It also aimed at assessing the level of thermal comfort produced by the five most commonly found species of trees. Data were gathered from the five species regarding air temperature, relative air humidity, and sun radiation both under and away from the treetops. The data were then organized, analyzed, and compared in order to assess thermal comfort, first by comparing under-the-treetop thermal comfort among the researched species, and then by comparing these with thermal comfort in the sorrounding area, away from the treetops. 1,817 units of plants were identified and, among these, the five most commonly found ones were: Licania tomentosa (Oiti), with 733 units, or 40.34%; Ficus benjamina L. (Ficus) with 152 units, or 8.36%; Terminalia catappa (Sete Copas), with 128 units, or 7.04%; Syzygium malaccense (L.) (Jambo), with 96 units, or 5.28%; and Caesalpinia peltophoroides Benth. (Sibipiruna), with 91 units, or 5.0%, totalling 1,200 units, or 66.04% of the total 1,817 units. It is also important to highlight that the use of these species for urban forestry demands judicious technical and landscape planning, undertaken by certified professionals, as these are large-sized trees which may bring more liabilities than benefits to the city and its population. / A arborização urbana tem como objetivo principal melhorar a qualidade de vida das populações nas cidades, uma vez que estas enfrentam vários problemas inerentes à urbanização. Os modelos utilizados para a arborização urbana nas cidades de Goiás, tem se mostrado ineficiente quanto a seus objetivos. Para uma avaliação mais aprofundada da arborização urbana, este trabalho foi desenvolvido na cidade de Uruaçu Goiás, cujos objetivos foram quantificar e qualificar as espécies da vegetação arbórea da cidade, e avaliar o conforto térmico produzido pelas cinco espécies de maior incidência identificadas. As espécies arbóreas identificadas contaram um total de 1.817 plantas, dentre estas, as de maior incidência foram: Licania tomentosa (Oiti) com 733 exemplares (40,34%), Ficus benjamina L. (Ficus) com 152 exemplares (8,36%), Terminalia catappa (Sete Copas) com 128 exemplares (7,04%), Syzygium malaccense (L.) (Jambo) com 96 exemplares (5,28%) e Caesalpinia peltophoroides Benth. (Sibipiruna) com 91 exemplares (5,0%), contabilizando 1.200 plantas (66,04%), do total de plantas identificadas. Dessas espécies foram coletados dados climáticos da temperatura e umidade relativa do ar, e radiação solar, sob suas copas e fora de suas copas. Os dados foram tabulados, analisados e comparados para a avaliação do conforto térmico entre as espécies sob a copa, e estas com o meio fora das copas. Ressalta-se que, para utilização dessas espécies na arborização urbana, há necessidade de um planejamento técnico criterioso, e paisagístico, proposto por profissionais habilitados, pois são plantas de grande porte, que podem trazer mais prejuízos do que benefícios à cidade e sua população.
88

Análise de conforto térmico em áreas abertas no município de Ourinhos - SP / Analysis of thermal comfort in open areas in Ourinhos

Carfan, Ana Claudia 05 July 2011 (has links)
Uma das conseqüências do aumento da população urbana e da modificação da paisagem é a alteração do clima local, criando um clima típico denominado clima urbano. Entender o clima urbano e buscar soluções para amenizar a influência de áreas construídas no clima de uma cidade é de grande interesse para a melhoria na qualidade de vida. Os modelos microclimáticos podem ser de grande utilidade no planejamento de cidades. Estes podem fornecer diretrizes para o planejamento arquitetônico, altura de edifícios, disposição de ruas e localização de áreas verdes trazendo um aumento do conforto térmico e dispersão de poluentes. O município de Ourinhos-SP está localizado no Sudoeste do Estado de São Paulo e faz divisa com o Estado do Paraná. Possui um clima do tipo subtropical, com inverno seco e verão chuvoso. O objetivo deste trabalho é analisar o clima urbano e o conforto térmico no município de Ourinhos, tendo para isso o modelo tridimensional ENVI-met como ferramenta principal de simulação das variáveis meteorológicas. Esse modelo possibilita a análise da temperatura do ar, umidade relativa do ar, direção e velocidade do vento além dos índices de conforto térmico PMV (Predicted Mean Vote) e PPD (Predicted Percentage of Dissatisfied) tendo por base a configuração da cidade. Efetuaram-se simulações para três áreas no município de Ourinhos, sendo duas no interior da área urbana e uma área suburbana. As simulações ocorreram para os dias 10/06/2009, inverno na região e dia 15/02/2010, situação de verão. Para o ponto situado no centro da cidade realizou-se, além da situação real, três simulações distintas alterando a estrutura através do aumento da altura das edificações, através da retirada das edificações da quadra central e instalação de um parque com vegetação rasteira e árvores e por meio da rotação da planta baixa da área urbano denso de 76º, onde a avenida principal antes com orientação NNO/SSE passa a ter orientação L/O. Pode-se observar que o modelo simula com razoável precisão as temperaturas obtidas em comparação aquelas medidas nas estações e através do coeficiente de determinação obteve-se que estes são significativos. Estes estudos mostraram que existe uma forte correlação entre a parte física da cidade (ruas, edificações e vegetação) e o conforto térmico humano. A situação de conforto para o verão e inverno é bastante diferenciada. Na análise dos índices de conforto PMV e PPD, no inverno somente a área urbano permeável não apresentou nenhuma área dentro dos limites de conforto estipulado pela norma ISSO 7730. No verão, a área urbano denso para a situação real e com aumento das edificações e a área expansão urbana apresentaram reduzidas áreas de conforto. As demais áreas, tanto no inverno quanto no verão apresentaram-se desconfortáveis. As propostas de modificação feitas, neste trabalho, não foram suficientes para mitigar o desconforto térmico das áreas urbanas abertas. / The increasing urban population and the modification of the landscape bring forth one consequence, the local climate change, developing a typical urban climate, known as urban climate. Understanding the urban climate and seek solutions to mitigate the influence of the buildings in the environment in a city is of great interest for improving the quality of life. The microclimatic models can be very useful in planning the cities. They can provide guidelines for the architectural planning, building heights, street layout and location of green areas by bringing in an increase in thermal comfort and pollutant dispersion. Ourinhos county is located in the southwestern state of Sao Paulo and is bordered by the state of Parana. It has a subtropical type climate with dry winter and rainy summer. This study aims to analyze the urban climate and thermal comfort in the city, using on this purpose the three-dimensional model ENVI-met as a main tool for simulation of meteorological variables. This model enables the researcher to analyze the temperature, relative humidity, wind direction, wind intensity and the thermal comfort indices PMV (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied) based on the configuration of the city. We carried out simulations in three areas in Ourinhos, two within the urban area and another in a suburban area. The simulations occurred at 10/06/2009, winter days in the region and 15/02/2010, the summer situation. The simulations took place at the center of the city, besides the actual situation, three different simulations, altering the structure by increasing the height of buildings, through the removal of buildings from the central block, a park with trees and creepers and by turning the ground floor of dense urban area of 76º, where the main avenue with prior oriented NNW / SSE direction is replaced by E / O. As observed, the model explains well the temperature obtained by comparison with those in the stations. Through the coefficient of determination it was found that these are significant. These studies showed that There is a strong correlation between the physical part of the city (streets, buildings and vegetation) and human thermal comfort. Summer and winter comfort situation is very different. Analyzing the comfort indices PMV and PPD in the winter, only the permeable urban area did not show any area within the comfort limits stipulated by ISO standard 7730. In summer, the dense urban area onto the actual situation and the increase of buildings and urban expansion area showed little comfort zones. The remaining areas, in both winter and summer were uncomfortable. Proposed changes made in this work were not enough to alleviate the discomfort of urban open areas.
89

Avaliação da eficiência térmica de materiais utilizados como sistemas de cobertura em instalações avícolas / Evaluation of the thermal efficiency of materials used as roofing systems in poultry houses

Castro, Ariane Cristina de 16 January 2012 (has links)
O objetivo principal desta pesquisa foi avaliar a redução na carga térmica radiante e o nível de conforto térmico proporcionado pelo uso de diferentes materiais na cobertura, e diferentes forros por meio de modelos em escala reduzida e distorcida, com base nos índices ambientais de conforto térmico. A pesquisa foi realizada em duas etapas, sendo a primeira no mês de maio de 2010 e a segunda durante os meses de junho e julho de 2010. Na primeira etapa com o objetivo de avaliar a eficiência dos forros como elementos atenuadores da radiação solar foi realizado o estudo de dois tipos de telhas (cerâmica e fibrocimento) associadas a dois tipos diferentes de forro (Forro A, Forro B) e sem forro. Os forros foram instalados na parte interior do modelo em escala abaixo do telhado. Na segunda etapa, foram avaliados as telhas cerâmicas e fibrocimento, associadas ao Forro A, Forro B e a Manta Termorefletora C. A Manta termorefletora C foi alocada sobre a instalação com o objetivo de simular as condições de conforto térmico proporcionado pelo sombreamento sobre o telhado. Para avaliar o desempenho térmico dos diferentes materiais para cobertura foram registradas as variáveis meteorológicas (temperatura do ar, umidade relativa, temperatura de globo negro e velocidade do vento) e partir dessas variáveis foram calculados os índices ambientais de conforto térmico (entalpia, índice de temperatura de globo e umidade e carga térmica radiante). Foram também registradas as variações de temperatura superficiais das telhas e dos forros para a identificação da variação espacial da temperatura em diferentes horários. A primeira etapa foi composta por 6 tratamentos e a segunda etapa por 5 tratamentos. A estrutura de parcelas para as duas etapas foi o delineamento em blocos ao acaso. A análise estatística foi realizada para diferentes horários por meio da análise da variância e do teste de Tukey para a comparação múltipla das médias, visando diferenciar os tratamentos. Os resultados permitiram concluir que: dentre os tratamentos avaliados houve diferenças estatísticas entre os materiais utilizados na cobertura, e nos respectivos forros. O material de forro B foi que apresentou as maiores reduções na CTR, e nos valores de ITGU. O mapeamento térmico da temperatura de superfície dos telhados evidenciou que as menores temperaturas foram encontradas nos telhados de fibrocimento pintados de branco. E as maiores temperaturas superficiais nas telhas de cerâmica, sem pintura. O uso do sombremento de telhados em modelos em escala reduzida e distorcida não promoveu melhoria nas condições térmicas do ambiente avaliado. / The main objective of this research was to evaluate the reduction in radiant thermal load (RTL) and the level of thermal comfort provided by the use of different roofs and lining materials, through reduced and distorted scale models based on environmental indexes of thermal comfort. The research was conducted in two phases, the first in May of 2010 and the second from June to July of 2010. The first phase aimed to evaluate the efficiency of lining as an element to attenuate solar radiation. Two types of tiles (ceramic and fibrous cement) were studied associated with two different liners (linings A and B). The liners were installed under the roof inside of the scale model. The second phase evaluated ceramic and fibrous cement tiles associated with liners A and B and with the thermal reflective blanket C, which was allocated over the installation in order to simulate the thermal comfort provided by the roof shading. To the evaluation of the thermal performance of the different roofing materials, meteorological variables were recorded (air and black globe temperatures, relative humidity and wind velocity), to the posterior calculation of thermal comfort environmental indexes (enthalpy, black globe temperature and humidity index GTHI and radiant thermal load). Variations on the surface temperature of tiles and liners were also recorded to identify the spatial variation of temperature at different times of the day. The first phase consisted of 6 treatments and the second consisted of 5 treatments. A completely randomized experimental design was adopted in the two phases. The statistical analysis was performed for the different times by analysis of variance and Tukeys test of multiple comparison of means, aiming to observe differences among the treatments. The results showed a statistical difference between the materials used for roofing and lining. Liner B presented the highest reductions of RTL and GTHI values. The thermal mapping of the surface temperature of tiles showed that the lowest temperature were found in fibrous cement roofs white painted, while the highest surface temperatures were found in the unpainted ceramic tiles. The use of shading roof in reduced and distorted scale models did not improve the thermal conditions of the evaluated environment.
90

Diretrizes projetuais para humanização hospitalar: Hospital de Clínicas da Universidade Federal do Triângulo Mineiro / Design guidelines for hospital humanization: teaching hospital of the Triângulo Mineiro Federal University

Garcia, Mariana Ferreira Martins 04 March 2016 (has links)
O Hospital de Clínicas da Universidade Federal do Triângulo Mineiro (HC UFTM) foi inaugurado em 1982 na cidade de Uberaba - MG e é, atualmente, o único hospital público do Triângulo Mineiro que oferece atendimento terceirizado de alta complexidade. Os critérios técnicos exigidos em normas rígidas para esses ambientes hospitalares dificultam o processo de humanização hospitalar como forma de atender os usuários satisfatoriamente e proporcionar espaços apropriados para o exercício dos profissionais da saúde e para auxiliar na cura dos pacientes. Sendo assim, o objetivo deste trabalho é propor diretrizes projetuais com a finalidade de melhorar o desempenho térmico e lumínico das alas de clínicas médica (CM) e cirúrgica (CC) do HC da UFTM. Para isso, a metodologia proposta consiste, inicialmente, num levantamento de dados dos aspectos projetuais e construtivos das alas estudadas. Posteriormente, foi feito um levantamento bioclimático de Uberaba dos últimos 10 anos junto a uma caracterização do edifício através dos cálculos das propriedades térmicas dos materiais e do uso das estratégias passivas no projeto. Para verificar a eficiência destas estratégias realizaram-se as análises dos métodos de Mahoney e Givoni. Além disso, o desempenho térmico e lumínico das alas de CM e CC foi analisado através das medições das temperaturas internas e externas, da umidade relativa do ar e dos níveis de iluminância. Depois, foram comparados com as recomendações de Mahoney e Givoni e à norma de iluminação NBR 8995-1. Os resultados encontrados indicaram que das estratégias passivas, a ventilação é a mais favorecida pela implantação do edifício, mas o resfriamento evaporativo e a alta inércia térmica não estão presentes. Além disso, os cálculos das 2 propriedades térmicas dos fechamentos verticais e horizontais e as medições das variáveis ambientais não apresentaram índices ideais de conforto e sim, altas transmitâncias, baixas inércias térmicas e, consequentemente, altas temperaturas no interior das alas, gerando um grande desconforto térmico praticamente o tempo todo. Além disso, os níveis de iluminância encontrados não estão adequados às normativas e, aliados a ambientes sem identidade visual desfavorecem ainda mais a percepção que os usuários/pacientes têm dos mesmos. Promover espaços ajardinados, melhorar o desempenho dos fechamentos através da utilização de isolantes térmicos e rever a concepção visual e os níveis mínimos de iluminação do HC são possibilidades eficientes e utilizadas em diversos hospitais para melhorar o conforto térmico e visual dos pacientes durante suas internações e assegurar qualidade no desempenho das tarefas dos funcionários. / In 1982, the teaching hospital (Hospital de Clínicas - HC) of the Triângulo Mineiro Federal University (UFTM) was opened in Uberaba, in Minas Gerais state in Brazil. Currently, it is the only public hospital in the Triângulo Mineiro area to offer third party high complexity services. Technical requirements in strict regulations for hospital environments make it harder to humanize them and satisfactorily assist users, provide health professionals with adequate working spaces and help the healing process. Therefore, this document aims to propose design guidelines to improve thermal and lighting performance in the medical clinic (clínica médica CM) and surgery clinic (clínica cirúrgica - CC) wings of the HC of UFTM. In order to achieve this, there was initially some data collection regarding design and building aspects related to the aforementioned hospital wings. Afterwards, it was necessary to gather data on the bioclimatic profile of Uberaba for the last ten years and relate it to the building using an estimate of the thermal properties of its materials and of the use of passive strategies in its design. To verify how effective the plans were, analyses based on Mahoney and Givonis methods were carried out. Furthermore, measurement of internal and external temperatures, of relative humidity and of illuminance levels were used to analyze thermal and visual performance of CM and CC wings. Then, the results were compared to Mahoney and Givonis recommendations and to lighting regulation NBR 8995-1. These results showed that regarding passive strategies, ventilation benefits the most from the building orientation, while evaporative cooling and high thermal inertia are absent. Moreover, thermal property figures of the vertical and the horizontal openings and measurements of environmental variables did 4 not present ideal comfort ratings, but high transmittance, low thermal inertia and, consequently, high temperatures inside the wings creating great thermal discomfort almost all the time. In addition, illuminance levels registered did not comply with regulations and, while associated with a lack of visual identity in rooms, caused users/patients to negatively perceive those rooms. Fostering green areas, improving insulation by using thermal insulation materials and revising the visual concept and the minimum illuminance levels in the HC are effective possibilities used in several hospitals to improve patients thermal and visual comfort while under treatment and to ensure quality to staff performance.

Page generated in 0.0526 seconds