• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 146
  • 41
  • 16
  • 12
  • 5
  • 1
  • 1
  • 1
  • Tagged with
  • 220
  • 129
  • 101
  • 73
  • 49
  • 46
  • 34
  • 32
  • 32
  • 28
  • 24
  • 23
  • 23
  • 23
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Thermométries ultrasonore et infrarouge pour le contrôle de la protection myocardique / Ultrasonic and infrared thermometries for the control of myocardial protection

Engrand, Céline H. 30 November 2016 (has links)
Le succès de la chirurgie cardiaque dépend essentiellement de la préservation des tissus durant l'opération. Afin d'optimiser cette dernière, une protection myocardique est appliquée à travers la perfusion d'une cardioplégie hypothermique lui permettant de tolérer l'ischémie provoquée par l'absence de vascularisation. Malgré ces progrès techniques et les connaissances accumulées, la chirurgie cardiaque reste une chirurgie à risque dont les complications sont parfois de nature inconnue. Il n'existe pourtant pas de suivi opérationnel de la protection myocardique et les seules indications disponibles pour le chirurgien sont l'arrêt contractile du cœur en début de cardioplégie ou l'apparition de fibrillations cardiaques dénonçant une inefficacité à long terme de la cardioplégie. Parmi les paramètres de mesure pouvant contribuer à la surveillance du myocarde sous cardioplégie, le suivi du changement de température induit par celle-ci pourrait devenir un indicateur pertinent. L'objectif de ce travail de thèse est donc de mettre en place un dispositif de suivi thermique du cœur permettant d'évaluer concrètement la diffusion et l'efficacité de perfusion cardioplégique durant la chirurgie cardiovasculaire.Parmi les méthodes de suivi thermique non invasives implantables en salle d'opération, la thermométrie par ultrasons (TUS) et la thermographie par infrarouges (TIR) ont retenu notre attention. Dans un premier temps, une méthode directe de thermométrie par ultrasons basée sur le principe "d'écho tracking" est expérimentée via un capteur ultrasonore $2,25 MHz mono-élément sur une gamme de température de 10 à 30°C. Cependant la caractérisation du muscle cardiaque par ultrasons et les expérimentations menées en laboratoire ont mis en avant la complexité du milieu nécessitant une calibration préalable, difficile à mettre en place en conditions opératoires. La technique présente tout de même une précision de mesure satisfaisante pour une variation de température inférieure à 10°C. Un modèle d'ajustement est alors proposé afin d'identifier la tendance de réchauffement interne du cœur à partir de la température de surface mesurable via une caméra thermique à infrarouge et par l'estimation volumique du milieu par ultrasons. Le modèle est validé dans un premier temps par simulation par éléments finis et dans un second temps durant des expérimentations sur fantômes et cœur in-vitro.Au final, le dispositif multi-physique TIR et TUS est expérimenté sur modèle in-vivo lors d'opérations, durant lesquelles des sessions de refroidissement par cardioplégie hypothermique sont effectuées. L'étude se conclut sur des premiers résultats de suivi thermique satisfaisants où les températures surfaciques acquises par TIR et l'estimation de l'épaisseur des parois ventriculaires par ultrasons permettent d'obtenir efficacement la tendance de réchauffement du myocarde. Le dispositif multi-physique a également démontré la possibilité d'appliquer une calibration directe de la thermométrie ultrasonore. Cette étude de faisabilité a démontré la possibilité d'un monitoring thermique du cœur de manière non invasive et applicable en temps réel. Ce dispositif pourrait être, après adaptation spécifique, implémenté durant les interventions cardio-vasculaire et fournir un indicateur précieux aux chirurgiens quant à l'efficacité de la protection myocardique. / The success of cardiac surgery essentially depends on tissue preservation. To optimize this latter, a myocardial protection is applied thanks to a hypothermic cardioplegia that confers a marked protective effect to the heart under ischemia. Despite these technical developments, cardiac surgery still presents risks and complications are sometimes of an unknown nature. However, no operational real-time monitoring of myocardial tissue exists. Among the metrics that could be analyzed, the temperature change measurement may be a relevant indicator. The objective of the present thesis is therefore to establish a thermal monitoring system of the heart in a way to evaluate the quality of the cardioplegia perfusion during cardiovascular surgery.Among the non-invasive thermal monitoring methods implantable in the operating room, the ultrasonic thermometry and infrared thermography caught our attention. In the first stages of the study, a direct method of ultrasonic thermometry based on the echo tracking is performed on in-vitro samples with 2.25 MHz ultrasonic sensor in a temperature range between 10 to 30°C. The ultrasonic characterization of the heart muscle and the laboratory experiments brought to the forth an environmental complexity requiring prior calibration that may be difficult to implement in operational conditions. However, the technique has a satisfactory measurement accuracy for temperature variations of less than 10°C.An adjustment model is then proposed to identify the in-depth warming trend of the heart thanks to the surface temperature measurement performed by thermal infrared camera and the medium thickness estimated by ultrasound. The model is validated by finite element simulations and experiments realized on ghosts and in-vitro heart samples.Finally, the device is experimented on in-vivo animal models while hypothermic cardioplegia were conducted. Conclusive results were obtained on the heart thermal monitoring. In particular, the surface temperatures acquired by infrared thermography and the thickness estimation of the ventricular walls by ultrasound allowed an estimation of the myocardial-warming trend.This feasibility study has demonstrated the possibility of heart thermal monitoring, noninvasively and appropriate in real time. After specific adaptation, this device could be implemented during cardiovascular interventions and provide a valuable indicator for the surgeons about the efficacy of myocardial protection.
162

Anwendung der Infrarot-Thermographie zur Überwachung der Temperatur der Körperoberfläche im Kopfbereich während der thermischen Enthornung von Deutsch-Holstein Kälbern unter Stallbedingungen

Früchtl, Lisa 10 December 2021 (has links)
Bei der Infrarot-Thermographie handelt es sich um eine nicht invasive, schnelle, berührungslose, bildgebende Methode zur Messung der Wärmestrahlung von Oberflächen, die bereits bei einigen veterinärmedizinischen Fragestellungen zum Einsatz gekommen ist. Ziel der Studie war es, die Oberflächentemperaturen im Kopfbereich von weiblichen Deutsch-Holstein Kälbern um den Enthornungszeitraum mittels Thermographie darzustellen und zu prüfen, welchen Einflussfaktoren die thermographischen Messungen unterlegen sind. Hierfür wurden acht Lokalisationen im Kopfbereich (linkes Auge (liAu), rechtes Auge (reAu), linke Hornanlage (liHa), rechte Hornanlage (reHa), Flotzmaul (FM), Schleimhaut des Flotzmauls (SHFM)) von gesunden, weiblichen Deutsch-Holstein Kälbern mit einer High-End Wärmebildkamera (ThermoPro TP8, Firma DIAS Infrared GmbH) im Rahmen eines standardisierten Studienprotokolls thermographisch untersucht. Die statistische Auswertung pro Merkmal erfolgte mit SAS, Vers.9.4. Die Umgebungstemperatur hatte den größten Einfluss auf die Oberflächentemperaturen (Regressionskoeffizienten von 0,10 bis 0,32; p < 0,01). Die Luftfeuchtigkeit wirkte sich nicht auf die Messergebnisse aus (p > 0,33). Die rektal erfasste Körperinnentemperatur korrelierte nur schwach mit den thermographisch ermittelten Oberflächentemperaturen. Hingegen konnte mit zunehmendem Alter der Tiere ein Abfall der Oberflächentemperaturen beobachtet werden (Regressionskoeffizienten von – 0,42 bis – 0,14; p < 0,01). Die Wiederholbarkeit der unmittelbar aufeinanderfolgenden thermographischen Doppelmessungen pro Lokalisation war sehr gut (r > 0,95). An den verschiedenen Lokalisationen wurde Wärme in unterschiedlichem Maße emittiert, wobei die Augen die höchsten und das Flotzmaul die niedrigsten Oberflächentemperaturen aufwiesen. Die paarigen Lokalisationen (liAu:reAu, liHA:reHa) wiesen ein symmetrisches Wärmestrahlungsmuster auf. Unter Beachtung der genannten Einflussfaktoren konnte direkt nach Abnahme des Brenners an den Ha der Kälber nach thermE eine Maximaltemperatur von ca. 67 °C ermittelt werden. Fünf und 30 Minuten nach dem Eingriff kam es zu einem signifikanten Temperaturabfall an den Ha der Tiere nach thermE, während die Oberflächentemperaturen der anderen Lokalisationen bei den Kälbern beider Gruppen im Vergleich zum Ruhewert anstiegen (p < 0,01). Zu den Messungen 60, 90 und 120 Minuten kam es weiterhin zu einem stetigen Temperaturanstieg (UliHa, liAu, FM, SHFM, reAu, UreHa) bzw. einem Temperaturplateau (liHa, reHa). Vier, spätestens acht Stunden nach Enthornung war das Niveau des Ruhewertes an allen Lokalisationen (exkl. FM, SHFM) wieder erreicht. Aufgrund des analogen Verlaufs der Oberflächentemperaturen der vorliegenden Studie mit dem Verlauf der Kortisolkonzentration im Blut von thermisch enthornten Kälbern ähnlich angelegter Studien lässt sich vermuten, dass es sich dabei um eine perioperative Stressantwort handeln könnte. Weitere Untersuchungen sind nötig, um einen möglichen Einsatz der Thermographie zur nicht invasiven Stressevaluierung zu prüfen.:1. Einleitung 1 2. LITERATURÜBERSICHT 3 2.1. Hornwachstum und Unterschiede in der Hornausbildung 3 2.2. Innervation der Hornanlagen 3 2.3. Enthornung 4 2.3.1. Definition und Methoden der Enthornung 4 2.3.2. Gründe für Enthornung 5 2.3.3. Alternativen zur Enthornung 6 2.3.3.1. Haltung behornter Rinder 6 2.3.3.2. Zucht auf Hornlosigkeit 6 2.4. Schmerz und Stress 7 2.4.1. Schmerz und Stress bei Rindern 7 2.4.2. Stress ausgelöst durch den Umgang mit Menschen 8 2.4.3. Durch den Stressor Enthornung ausgelöste Schmerz- und Stressantwort 9 2.4.4. Schmerz- und Stressevaluierung während der thermischen Enthornung 9 2.5. Thermographie 11 2.5.1. Prinzip der Thermographie 11 2.5.2. Einflussfaktoren auf die Thermographie unter Stallbedingungen 12 2.5.2.1. Vom Tier ausgehende Einflussfaktoren 13 2.5.2.2. Von außen einwirkende Einflussfaktoren 13 2.5.2.3. Einfluss der Aufnahmetechnik 13 2.5.3. Thermographie in der Veterinärmedizin 14 2.5.4. Thermographie bei Rindern 14 2.5.5. Thermographie zur Überwachung der thermischen Enthornung 16 2.5.6. Schlussfolgerung aus der Literaturrecherche und Zielstellung 16 3. Material und Methoden 18 3.1. Auswahl der für die Durchführung der Studie zu verwendenden Wärmebildkamera 18 3.1.1. Kriterien für den Einsatz einer Wärmebildkamera am Tier unter Stallbedingungen 18 3.1.2. Pro- und Contra-Kriterien 19 3.1.3. Technische Daten der Wärmebildkameras testo882 und ThermoPro TP8 21 3.1.4. Vorversuch mit den Wärmebildkameras testo882 und ThermoPro TP8 22 3.1.5. Schlussfolgerung und Entscheidung 23 3.2. Protokoll für die standardisierte Erstellung qualitativ hochwertiger Thermogramme 23 3.2.1. Position von Wärmebildkamera und Kalb 23 3.2.1.1. Standardisierte Erstellung von Thermogrammen an den Augen 24 3.2.1.2. Standardisierte Erstellung von Thermogrammen am Flotzmaul und der Maulschleimhaut 25 3.2.1.3. Standardisierte Erstellung von Thermogrammen an den Enthornungsstellen und deren Umgebung 25 3.2.2. Optimale Fokussierung 26 3.2.2.1. Thermogramme der Augen 26 3.2.2.2. Flotzmaul und Maulschleimhaut 26 3.2.2.3. Enthornungsstellen und deren Umgebung 26 3.2.3. Schlussfolgerung zur Erstellung qualitativ hochwertiger Thermogramme 26 4. Publikation 1 27 5. Publikation 2 38 6. Diskussion 50 6.1. Diskussion des Studienprotokolls 50 6.1.1. Auswahl der Lokalisationen 50 6.1.1.1. Thermographische Erfassung der Oberflächentemperaturen an den Augen 50 6.1.1.2. Thermographische Erfassung der Oberflächentemperaturen am Flotzmaul und der Maulschleimhaut 51 6.1.1.3. Thermographische Erfassung der Oberflächentemperaturen an den Hornanlagen und deren Umgebung 51 6.1.1.4. Abschließende Beurteilung der Messbarkeit der Oberflächentemperaturen an den Lokalisationen 52 6.1.2. Auswahl der Messzeitpunkte 52 6.1.2.1. Ruhewerte vor der thermischen Enthornung 53 6.1.2.2. Kurzfristige Auswirkungen der thermischen Enthornung 53 6.1.2.3. Langfristige Auswirkungen der thermischen Enthornung 54 6.1.2.4. Schlussfolgerung 54 6.1.3. Einflussfaktoren 55 6.1.3.1. Einfluss der Aufnahmetechnik 55 6.1.3.1.1. Abstand zwischen Kamera und Lokalisation am Kopf des Kalbes 55 6.1.3.1.2. Winkel zwischen Kamera und Lokalisation am Kopf des Kalbes 55 6.1.3.2. Von außen einwirkende Faktoren 55 6.1.3.2.1. Umgebungstemperatur 55 6.1.3.2.2. Luftfeuchtigkeit 56 6.1.3.2.3. Sonneneinstrahlung 56 6.1.3.3. Vom Tier ausgehende Einflussfaktoren 57 6.1.3.3.1. Stress 57 6.1.3.3.2. Zirkadiane Rhythmik 57 6.1.3.3.3. Alter der Tiere 57 6.1.3.3.4. Innere Körpertemperatur (IKT) 58 6.1.3.4. Schlussfolgerung 58 6.2. Hitzeentwicklung im Kopfbereich 59 6.2.1. Hitzeeinwirkung durch die thermische Enthornung 59 6.2.2. Evaluierung hitzebedingter Schmerzen 59 6.2.3. Thermische Enthornung und Schmerzmanagement 60 6.2.3.1. Hintergrund zur Entscheidung der thermischen Enthornung ohne multimodales Schmerzmanagement 60 6.2.3.2. Ergebnisse, die durch die Einbeziehung einer Kontrollgruppe generiert werden konnten 60 6.3. Negative Auswirkungen durch fehlerhafte thermische Enthornung 61 6.4. Potentielle Möglichkeiten des Einsatzes der Wärmebildkamera in der Kälberhaltung 62 6.4.1. Stressmonitoring 62 6.4.2. Gesundheitsmonitoring 63 7. Zusammenfassung 66 7.1. Einleitung 66 7.2. Ziele der Untersuchungen 66 7.3. Tiere, Material und Methoden 66 7.4. Ergebnisse 67 7.5. Schlussfolgerung 67 8. Summary 68 8.1. Introduction 68 8.2. Objectives 68 8.3. Animals, Materials and Methods 68 8.4. Results 69 8.5. Conclusions 69 9. Literaturverzeichnis 70 10. Danksagung 82
163

Fluctuations de température en aval d'une jonction orthogonale d'écoulements turbulents de températures différentes

Menanteau, Sébastien 20 March 2012 (has links)
La problématique associée à ce travail de thèse concerne la détermination des causes de fatigue thermique dans des conduites hydrauliques. Ce travail porte plus particulièrement sur l’étude d’une zone de mélange orthogonale dans laquelle débouchent deux écoulements à différentes températures et présentant des régimes dynamiques turbulents. Ce type de configuration est utilisé afin de favoriser la baisse de température de l’écoulement (ou l’augmentation de température selon les cas). Pour des valeurs élevées du nombre de Reynolds et des écarts de températures des écoulements en confluence, la charge thermique engendrée par les fluctuations pariétales de température peut entraîner la formation de fissures dans les canalisations.Pour faire face à ce problème, les méthodes de dimensionnement des conduites hydrauliques mettent en évidence la nécessité de connaître la charge thermique imposée sur la paroi sensible. Le besoin attendu en termes de caractérisation dynamique et thermique de ces écoulements est à l’origine de ce projet de recherche qui s’attache ainsi à déterminer pour une configuration industrielle simplifiée, les phénomènes dynamiques et thermiques instationnaires et tridimensionnels à proximité de la paroi. Pour cela, l’étude s’organise en deux phases. Une approche expérimentale, faisant appel à la vélocimétrie par images de particules et la thermographie infrarouge, est mise en oeuvre dans un écoulement turbulent à la jonction entre une conduite de section rectangulaire et un piquage cylindrique. L’étude expérimentale permet de mesurer l’effet de différents paramètres de l’écoulement (régime dynamique, rapport des vitesses de l’écoulement, écart de température). Une des configurations expérimentales est de plus modélisée par simulations des grandes échelles dans laquelle le transfert thermique conjugué entre le fluide et la paroi d’intérêt est pris en compte. Les champs statistiques de vitesse et température issus du calcul numérique sont comparés à la base de données expérimentale. L’analyse des mécanismes thermodynamiques près de la paroi et dans la paroi, est de plus réalisée au moyen des grandeurs statistiques de l’écoulement, des corrélations de vitesse-température et de l’enregistrement temporel de sondes numériques placées dans l’écoulement et dans la paroi. / This research work originates from thermal stress issues in hydraulic pipes. It specifically focuses on determination of thermal load created by mixing flows in orthogonal pipe junctions. Such mixing zones are commonly used to cool or heat the main flow. For high Reynolds number values and high difference of temperature of the two flows, thermal load created by strong temperature fluctuations at the wall can initiate and propagate cracks through the pipe. Standards in pipe design pointed out the need in knowing these thermal loads applied at the downstream junction wall. Thus, this study aims to characterize three-dimensional and unsteady dynamical and thermal phenomena in a simplified industrial configuration. First, an experimental investigation based on particle image velocimetry and infrared thermography has been carried out on a cylindrical jet pipe flowing through a main rectangular channel flow. Different parameters have been studied such as Reynolds number influence, velocity ratio between secondary and main flow and temperature difference. One of the experimental configurations has also been investigated using numerical simulations. LargeEddy Simulations with conjugate heat transfer model has been developed and compared to the experimental database. Dynamics and Thermal mechanisms have been analysed near the wall and within the wall with obtained statistical flow fields, velocity-temperature moments and numerical probes extracted from fluid and solid parts.
164

Simultaneous characterization of objects temperature and radiative properties through multispectral infrared thermography / Caractérisation conjointe de la température et des propriétés radiatives des objets par thermographie infrarouge multispectrale

Toullier, Thibaud 06 November 2019 (has links)
L'utilisation de caméras infrarouges bas coûts pour la surveillance long-terme d'infrastructures est prometteuse grâce aux dernières avancées technologiques du domaine. Une mesure précise de la température des surfaces observées in-situ se heurte au manque de connaissance des propriétés radiatives de la scène. L'utilisation d'une instrumentation multi-capteurs permet d'affiner le modèle de mesure afin d'obtenir une estimation plus précise de la température. A contrario, il est montré qu'il est toujours possible d'exploiter des données climatiques en ligne pour pallier un manque de capteur. Des méthodes bayésiennes d'estimation conjointe d'émissivité et de température sont ensuite développées et comparées aux méthodes de la littérature. Un simulateur d'échanges radiatifs diffus de scènes 3D a été implémenté afin de tester ces différentes méthodes. Ce logiciel utilise l'accélération matérielle de la machine pour réduire les temps de calcul. Les résultats numériques obtenus mettent en perspective une utilisation avancée de la thermographie infrarouge multi-spectrale pour la surveillance de structures. Cette estimation conjointe permet alors d'obtenir un estimé de la température par thermographie infrarouge avec une incertitude connue. / The latest technological improvements in low-cost infrared cameras have brought new opportunities for long-term infrastructures monitoring. The accurate measurement of surfaces' temperatures is facing the lack of knowledge of radiatives properties of the scene. By using multi-sensors instrumentation, the measurement model can be refined to get a better estimate of the temperature. To overcome a lack of sensors instrumentation, it is shown that online and free available climatic data can be used. Then, Bayesian methods to estimate simultaneously the emissivity and temperature have been developed and compared to literature's methods. A radiative exchange simulator of 3D scenes have been developed to compare those different methods on numerical data. This software uses the hardware acceleration as well as a GPGPU approach to reduce the computation time. As a consequence, obtained numerical results emphasized an advanced use of multi-spectral infrared thermography for the monitoring of structures. This simultaneous estimation enables to have an estimate of the temperature by infrared thermography with a known uncertainty.
165

Caractérisation thermique et lumineuse de diodes électroluminescentes en charge par méthodes locales non intrusives : influence du luminophore / Thermal and luminous characterization of charged light emitting diodes (LED) by local non-intrusive methods : effect of phosphor

Lacourarie, Fiona 17 July 2015 (has links)
Le marché des diodes électroluminescentes (LEDs) de puissance est en perpétuelle croissance depuis une vingtaine d’années. Le marché de l’éclairage évolue car les besoins ont changé : nous souhaitons, par exemple, aujourd’hui réduire la consommation électrique, ou avoir des éclairages plus flexibles (couleur, cycle d’allumage, encombrement, …). Les LEDs de puissance permettent d’apporter des solutions où les autres éclairages font défauts. Une étude comparative est menée entre les LEDs et les autres sources d’éclairages. Une LED de puissance émettant une lumière blanche est constituée d’une puce semi-conductrice, d’un substrat, d’un PAD et d’une optique primaire. Différentes méthodes permettent d’obtenir de la lumière blanche avec des LEDs : plusieurs puces, une puce avec un ou des luminophores, ou la méthode PRS-LED. Le luminophore a un rôle optique important et un rôle thermique non négligeable. Après avoir été excité par la lumière émise de la puce, il réémet de la lumière dans une longueur d’onde supérieure. L’efficacité de ce processus dépend de nombreux paramètres, comme la mise en oeuvre du luminophore ou le type de luminophore utilisé. L’étude et la caractérisation des propriétés optiques et thermiques sont faites pour des LEDs commerciales, composées d’une même puce émettant de la lumière bleue, avec et sans luminophore jaune. Afin de maitriser le maximum de facteurs, nous avons mené une étude et un dimensionnement du circuit imprimé (PCB) sur lequel va être implanté nos LEDs. Dans le but d’évaluer les matériaux constituant les LEDs, des analyses au microscope à balayage électronique et par microsonde ont été menées. Ces travaux ont permis de révéler, notamment, la position de la jonction p-n dans la puce et la composition de la couche de luminophore par deux types différents. De plus, afin d’améliorer notre compréhension, une étude comparative a été menée sur trois luminophores jaunes. Ensuite, les deux types de LEDs, puce nue et puce avec luminophore, ont été testés dans le but d’obtenir le flux lumineux et le rendement des LEDs. La caractérisation optique nous a amené à créer un banc pour obtenir la luminance énergétique spectrale sur une partie minime de la puce. D’autre part, nous nous intéressons à la température de jonction de la puce nue, que nous mesurons par différentes méthodes, dont la thermographie infrarouge. Pour cela, l’émissivité a été estimée pour la puce nue et la puce avec luminophore. Puis nous comparons aussi ces différentes méthodes pour le calcul de la résistance thermique Rth j-PAD entre la jonction et le PAD. Le maillage de fils conducteurs implanté sur la surface de la puce est modélisé électriquement. Cette étude, qui est composée de niveaux progressifs de modélisation, permet de comprendre la répartition du courant électrique qui traverse la jonction, et ainsi d’appréhender la répartition du flux lumineux et de la température au niveau de la surface de la puce. Après, un modèle thermo-optique décrit les phénomènes présents au niveau de la jonction d’une puce nue : la conversion de la puissance électrique en lumière bleue et en chaleur, et les transferts de chaleur. Nous complétons ce premier modèle pour obtenir un modèle d’une puce avec le luminophore. Ce dernier modèle prend en compte la photo-conversion du luminophore avec le calcul de flux lumineux à la sortie du luminophore et le calcul de la chaleur due à la photo-conversion. La résolution de ce modèle nous permet d’obtenir la température de jonction d’une puce avec luminophore. La conservation d’énergie du modèle est aussi vérifiée. Le modèle thermo-optique est appliqué à une cartographie de température de surface afin d’obtenir une cartographie de la température de jonction. Ces cartographies sont regroupées avec les clichés de thermographie infrarouge et de luminance énergétique. / The high brightness LED market is constantly growing last twenty years. The lighting market is changing as needs have changed: we would like, for example, reduce power consumption, or have more flexible lighting (color, lighting cycle, dimensions ...). High brightness LEDs help provide solutions where others are lighting defects. A comparative study is conducted between the LEDs and other lighting sources.The operation of a high brightness LED emitting white light is explained with the description of each element: chip, substrate, the PAD and optics. Then the different methods of obtaining white light with LEDs are compared: several chips, a chip with one or more phosphors, or PRS-LED method. The phosphor has a significant optical role and an important thermal role. After being excited by the light emitted from the chip, it re-emits light in a greater wavelength. The effectiveness of this process depends on many parameters, such as the implementation of the phosphor, or the type of phosphor used. The study and characterization of optical and thermal properties are made for commercial LEDs, composed of a single chip emitting blue light with and without yellow phosphor. To master the maximum factors, we conducted a study and design of the printed circuit board (PCB) on which will be implanted our LEDs. In order to evaluate the materials constituting the LEDs, analyzes made at scanning electron microscope, and by microprobe were conducted. This work has revealed in particular the position of the p-n junction in the chip, and the composition of the phosphor layer of two different types. Moreover, to improve our understanding, a comparative study will be conducted on three yellow phosphors. Then the two types of LEDs, bare chip and chip with phosphor, were tested in order to obtain the luminous flux and efficiency of LEDs. The optical characterization has led us to create a bench for spectral radiance over a small portion of the chip. Furthermore, we are interested in the junction temperature of the bare chip, which we measure by various methods, including infrared thermography. For this, the emissivity was estimated for the bare chip and the chip with phosphor. Then we also compare these different methods to calculate the thermal resistance Rth j-PAD between the junction and the PAD. The mesh of conductive wires, implanted on the surface of the chip, is electrically modeled. The study, which is composed of three progressive levels of modeling, provides an understanding of distribution of the electric current through the junction, and thus to understand the distribution of the light flow and temperature at the surface of the chip. Afterwards, an optical-thermal model describes the phenomena present at the junction of a bare chip: converting electrical power into blue light and heat, and heat transfer. We complete this first model for a model of a chip with the phosphor. This model takes into account the photo-conversion of the phosphor with the calculation of the luminous flux at the output of the phosphor and the calculation of the heat due to the photo-conversion. The resolution of this model allows us to obtain the junction temperature of a chip with phosphor. The model of energy conservation is also verified. The optical-thermal model is applied to a surface temperature mapping in order to obtain a mapping of the junction temperature. These maps are combined with pictures of infrared thermography and radiance.
166

L’impact des systèmes de logement alternatifs sur la santé et les performances des poules pondeuses

Denis, Éloïse 08 1900 (has links)
Alors que les producteurs d'œufs canadiens font la transition des cages conventionnelles vers les systèmes de logement alternatifs, il est important de déterminer l’impact de ceux-ci sur le bien-être et les performances des poules pondeuses. L’objectif de cette étude était d’évaluer la prévalence de déviation du bréchet, de fracture du bréchet, de dermatite du coussinet plantaire et l’état du plumage dans les fermes commerciales du Québec, Canada. Le taux de ponte, la mortalité cumulée, la consommation alimentaire, l’épaisseur de la coquille, le poids de l’œuf, la force de la coquille, l’unité Haugh et la prévalence d’œufs sales et craqués ont été utilisés pour déterminer la performance du troupeau. L’utilisation de la thermographie infrarouge comme outil diagnostique pour les fractures du bréchet et les dermatites du coussinet plantaire a également été évaluée. Les données révèlent que les poules maintenues en volières présentent une prévalence de fracture du bréchet (P=0,011) et une mortalité (P=0,0049) plus élevée, en plus de produire des œufs avec une épaisseur de coquille supérieure comparativement aux poules maintenues en cages enrichies (P=0,0049). Une faible consommation alimentaire était corrélée avec une prévalence élevée de poules présentant une perte de plumes (P < 0,05) et une consommation alimentaire élevée était corrélée avec un poids d’œufs élevé (P < 0,05). Les systèmes de logement n’ont pas influencé les autres paramètres étudiés. Globalement, les volières impactent négativement les fractures du bréchet, les dermatites du coussinet plantaire ainsi que la mortalité et la thermographie infrarouge n’est pas un outil diagnostique fiable. / As Canadian egg farmers transition their flocks from conventional cages to alternative housing systems, it is important to evaluate the impact of the latter on the performance and welfare of laying hens. To this end, the present study investigates the prevalence of keel bone deviation, keel bone fracture, footpad dermatitis and feather coverage in commercial flocks in Quebec, Canada, housed in enriched cages and aviaries. Mean egg production, cumulative mortality, feed intake, shell thickness, egg weight, shell strength, Haugh unit, and the prevalence of cracked or dirty eggs were used as measures of flock performance. The present study also investigates the use of infrared thermography as a diagnostic tool for keel bone fractures and footpad dermatitis in hens. Our data show that hens housed in aviaries have a significantly higher prevalence of keel bone fracture (P=0.011) and cumulative mortality (P=0.0049) but that the egg shells of aviary hens are significantly thicker than their counterparts in enriched cages (P=0.0049). While thermal imaging could not distinguish between hens with and those without fractures, footpad temperatures were significantly higher in hens with severe dermatitis (P<0.01). Furthermore, a low feed intake positively correlated with damaged feather coverage (P<0.05), while high feed intake correlated with high egg weight (P<0.05). The other parameters studied were not influenced by the type of housing. Overall, aviary housing negatively impacted keel bone fractures, footpad dermatitis and mortality and infrared thermography is not a valid diagnostic tool for keel fracture and footpad dermatitis in hens.
167

Die subklinische Klauenrehe beim Milchrind - thermographische Untersuchungen der Klaue und Beziehungen zum Energiestoffwechsel

Wilhelm, Katrin 30 March 2010 (has links)
Die subklinische Klauenrehe stellt als Ausgangspunkt für eine Vielzahl daraus resultierender Klauenerkrankungen einen wichtigen Faktor in Bezug auf Tierschutz und Wirtschaftlichkeit von Hochleistungsmilchkühen dar. Die Ätiologie und Pathogenese dieser komplizierten Klauenerkrankung ist bis heute noch nicht eindeutig geklärt. Eine Vielzahl von Faktoren kann die Klauenlederhaut im Sinne einer Reheentwicklung negativ beeinflussen. In der vorliegenden Arbeit sollte der Einfluss der negativen Energiebilanz nach der Kalbung und eines daraus resultierenden Fettmobilisationssyndroms auf die Entwicklung rehetypischer Anzeichen an den Klauen untersucht werden. Weiterhin sollte geprüft werden, inwieweit die thermographische Untersuchung der Klauen nach der Kalbung, also dem predistinierten Zeitpunkt für die Entwicklung einer Klauenrehe, in der Lage ist, Aufschluss über den Entzündungszustand der Lederhaut zu geben und dementsprechend als frühdiagnostisches Mittel zur Erkennung der subklinischen Klauenrehe Anwendung finden kann. Die Temperaturverteilung über die einzelnen Hauptklauen und die Veränderung dieser im Laufe der Frühlaktation, sowie Unterschiede zwischen primiparen und multiparen Tieren wurde untersucht. Hierfür wurden die Klauen von 123 Kühen und Färsen bzw. Jungkühen aus drei Milchviehanlagen mit ähnlichen Jahresleistungen und verschiedenen Stallböden in der ersten Woche nach der Kalbung, sowie nach Vollendung des zweiten Laktationsmonats bezüglich des Vorliegens einer Lahmheit und, nach der Durchführung einer funktionellen Klauenpflege, auf Anzeichen der subklinischen Klauenrehe durch Vergabe eines Klauenscores untersucht und zusätzlich mittels Thermographie der Fußungsfläche analysiert. Um den Einfluss des Stoffwechsels auf die Reheentwicklung definieren zu können, erfolgten im Zeitraum von 8 Wochen vor der Kalbung bis 8 Wochen nach der Kalbung in regelmäßigen Abständen Messungen der Rückenfettdicke sowie Blutprobenentnahme zur Bestimmung der jeweiligen Freien-Fettsäuren- (FFS), ß-Hydroxybutyrat- (BHB) und Glucosekonzentrationen. Um den Einfluss anderer Stoffwechselentgleisungen abzugrenzen, wurden weiterhin die Parameter Lactat, Gesamtprotein, Albumin, Harnstoff, Calcium, Creatinkinase (CK), Aspartataminotransferase (ASAT) und Lactatdehydrogenase (LDH) bestimmt. Bei der Beurteilung von Lahmheit und Reheanzeichen stellte sich eine signifikante Zunahme letztgenannter nach dem zweiten Laktationsmonat dar. Die Lahmheitsinzidenz nahm dagegen leicht ab. Gummiböden hatten insgesamt einen positiven Effekt auf die Reheentwicklung. Jungkühe wiesen deutlich stärkere rehetypische Veränderungen (Hämorrhagien, Gelbverfärbungen im Horn, weiches Horn) auf als ältere Tiere. Die rehetypischen Veränderungen konzentrierten sich dabei bei allen Probanden auf die hinteren Lateralklauen. Die Thermographie zeigte gravierende Differenzen zwischen den Vorder- und Hintergliedmaßen, sowie zwischen Lateral- und Medialklauen. Die Hinterklauen waren deutlich (p<0,0001) wärmer als die Vorderklauen. Die Lateralklauen der Hintergliedmaßen zeigten sich wärmer als die Medialklauen, während es sich an den Vorderklauen tendenziell umgekehrt verhielt. Im Laktationsverlauf ließ sich eine leichte Zunahme der Differenzen beobachten, wobei sich die Absoluttemperaturen kaum unterschieden. Obwohl die Verteilung von rehetypischen Veränderungen dem Muster der Temperaturverteilung über die Hauptklauen entsprach (hintere Lateralklauen hatten die meisten rehetypischen Veränderungen und die höchsten Temperaturen), konnte keine eindeutige Korrelation zwischen der Klauentemperatur nach der Kalbung und den sichtbaren Reheveränderungen acht Wochen später gefunden werden. Die Temperaturverteilung auf den einzelnen Hauptklauen zeigte in den meisten Fällen (77,3 %) einen um ca. 2-3°C wärmeren Ballenbereich (Rusterholzstelle) im Vergleich zur Klauenspitze. Bei 16,5 % der Klauen waren beide Bereiche gleichwarm (Temperaturunterschied < 1°C) und bei einem geringen Anteil (6,2 %) zeigte sich die Spitze als wärmste Stelle an der Fußungsfläche. Zwischen der Höhe der Rückenfettdicke, der FFS-, BHB- und Glucosekonzentrationen und der Entwicklung einer subklinischen Klauenrehe ergaben sich keine aussagekräftigen Korrelationen. Tendenziell waren eher unterkonditionierte Tiere von Klauenveränderungen betroffen. Schlussfolgerung: Obwohl die Temperaturverteilung auf der Fußungsfläche dem Verteilungsmuster rehetypischer Veränderungen entsprach, war die Thermographie nicht als frühdiagnostisches Mittel zur Erkennung der subklinischen Klauenrehe geeignet. Die Temperaturen zwischen Vorder- und Hinterklauen sowie zwischen Lateral- und Medialklauen unterschieden sich deutlich. Eine direkte Beeinflussung der Klauen durch das Fettmobilisationssyndrom konnte in den hier durchgeführten Untersuchungen nicht gefunden werden.:1 EINLEITUNG 1 2 LITERATURÜBERSICHT 2 2.1 Anatomie der Klaue 2 2.1.1 Topographische Einteilung 2 2.1.2 Skelett 3 2.1.3 Haut 3 2.1.3.1 Unterhaut 3 2.1.3.2 Lederhaut 4 2.1.3.3 Oberhaut 4 2.1.4 Durchblutungsverhältnisse an der Klaue 5 2.1.4.1 Arterielle Versorgung 6 2.1.4.2 Venöse Versorgung 7 2.1.5 Druckverteilung auf die Klauen 8 2.2 Klauenrehe 9 2.2.1 Formen der Klauenrehe 9 2.2.1.1 Akute Klauenrehe 9 2.2.1.2 Subakute Klauenrehe 10 2.2.1.3 Chronische Klauenrehe 10 2.2.1.4 Subklinische Klauenrehe 11 2.2.2 Ätiologie der Klauenrehe 11 2.2.2.1 Fütterung 11 2.2.2.1.1 Kohlenhydratüberschuss und subklinische Pansenazidose (SARA) 11 2.2.2.1.2 Proteinüberversorgung 12 2.2.2.2 Haltung 13 2.2.2.2.1 Böden 13 2.2.2.2.2 Ethologie 13 2.2.2.3 Erkrankungen verschiedener Organsysteme 14 2.2.2.4 Alter 14 2.2.2.5 Genetik 15 2.2.2.6 Kalbung 15 2.2.3 Pathogenesetheorie zur Klauenrehe 16 2.3 Thermographie 19 2.3.1 Physikalische Grundlage und Einflussfaktoren 19 2.3.2 Wärmeverteilung über den Körper – Regulierung der Körpertemperatur 20 2.3.3 Interne Einflüsse auf die Körperoberflächentemperatur 20 2.3.4 Thermographie in der Veterinärmedizin 21 2.3.4.1 Thermographische Untersuchungen an Huf und Klaue in Bezug zu Rehe 22 2.4 Stoffwechsel 22 2.4.1 Energiestoffwechsel und Lipomobilisationssyndrom – potentielle Auswirkungen auf die Klauengesundheit 22 2.4.2 Weitere Stoffwechselparameter, welche verschiedene Erkrankungen mit eventuellem Einfluss auf die Klauengesundheit anzeigen 25 2.4.2.1 Eiweißstoffwechsel 25 2.4.2.2 Muskelstoffwechsel 26 2.4.2.3 Lactat 27 3 TIERE, MATERIAL UND METHODEN 28 3.1 Versuchsanordnung und Tiere 28 3.2 Haltung 28 3.3 Fütterung 29 3.3.1 Betrieb A 29 3.3.2 Betrieb B 29 3.3.3 Betrieb C 30 3.4 Probennahmen und Untersuchung der Klauen und Lahmheiten 30 3.4.1 Erfassung der Rückenfettdicke (RFD) 30 3.4.2 Blutproben 31 3.4.3 Klauenschnitt und –beurteilung 31 3.4.3.1 Beurteilung der Klauenfotographien 31 3.4.4 Thermographische Aufnahme der Klaue 33 3.4.4.1 Auswertung der thermographischen Aufnahmen 34 3.4.5 Beurteilung des Vorliegens einer klinischen Lahmheit 35 3.5 Klinisch-chemische Untersuchungen 35 3.6 Statistische Auswertung 37 4 ERGEBNISSE 38 4.1 Auswertung des Klauenscores und der klinischen Lahmheit 38 4.1.1 Klauenscore 38 4.1.1.1 Unterschiede zwischen Kühen und Färsen und zwischen den einzelnen Beständen 38 4.1.1.1.1 Klauenscore - Vergleich Kühe - Färsen 38 4.1.1.1.2 Klauenscore - Vergleich der 3 Bestände 39 4.1.1.1.3 Klauenscore - Vergleich Kühe – Färsen in den einzelnen Beständen 40 4.1.1.2 Verteilung des Klauenscores auf die einzelnen Klauen 41 4.1.1.2.1 Klauenscore- Vergleich Schulter- und Beckengliedmaße 41 4.1.1.2.2 Klauenscore - Vergleich Medial- und Lateralklauen 42 4.1.2 Lahmheit 43 4.1.2.1 Vergleich zwischen Kühen und Färsen und zwischen den Beständen 43 4.1.2.1.1 Lahmheit - Vergleich Kühe - Färsen 43 4.1.2.1.2 Lahmheit - Vergleich der 3 Bestände 44 4.1.2.2 Lahmheitsinzidenzen der 3 Herden 44 4.2 Auswertung des Einflusses von Erkrankungen verschiedner Organsysteme auf die Klauengesundheit 46 4.2.1 Auftreten verschiedener Erkrankungen 46 4.2.2 Zusammenhang zwischen Organerkrankungen und dem Klauenscore 46 4.2.3 Vergleich zwischen Kühen und Färsen und zwischen den Beständen 47 4.2.3.1 Erkrankungen verschiedener Organsysteme -Vergleich Kühe -Färsen 47 4.2.3.2 Erkrankungen verschiedener Organsysteme -Vergleich der 3 Bestände 48 4.3 Auswertung der Thermographie 49 4.3.1 Klauentemperatur - Einfluss der Umgebungstemperatur 49 4.3.2 Klauentemperatur - Vergleich von Schulter- und Beckengliedmaße sowie von Medial- und Lateralklaue 50 4.3.3 Vergleich zwischen Kühen und Färsen und zwischen den Beständen 51 4.3.3.1 Klauentemperatur - Vergleich Kühe - Färsen 51 4.3.3.2 Klauentemperatur - Vergleich der 3 Bestände 52 4.3.4 Temperaturverteilungsmuster auf der Klauensohle 53 4.3.4.1 Klauen mit wärmerem Ballenbereich im Vergleich zur Spitze 54 4.3.4.2 Klauen mit wärmerer Spitze im Vergleich zum Ballenbereich 55 4.3.5 Zusammenhang zwischen den Klauensohlentemperaturen und dem Klauenscore 56 4.3.6 Zusammenhang zwischen den Klauensohlentemperaturen und dem Vorliegen verschiedener Erkrankungen 57 4.4 Auswertung der Rückenfettdicke (RFD) 58 4.4.1 Entwicklung der RFD im Laktationsverlauf 58 4.4.2 Vergleich zwischen Kühen und Färsen und zwischen den Betrieben 59 4.4.2.1 RFD - Vergleich Kühe - Färsen 59 4.4.2.2 RFD - Vergleich der 3 Betriebe 60 4.4.3 Zusammenhang zwischen der RFD-Entwicklung und dem Klauenscore 61 4.5 Stoffwechsel 62 4.5.1 Verhalten der einzelnen Parameter im Laktationsverlauf 62 4.5.1.1 Freie Fettsäuren (FFS) 62 4.5.1.2 Glucose 63 4.5.1.3 ß-Hydroxybutyrat (BHB) 64 4.5.1.4 Gesamtprotein 65 4.5.1.5 Albumin 65 4.5.1.6 Harnstoff 65 4.5.1.7 Lactat 65 4.5.1.8 Creatinkinase (CK) 65 4.5.1.9 Lactatdehydrogenase (LDH) 65 4.5.1.10 Aspartataminotransferase (ASAT) 66 4.5.1.11 Calcium 66 4.5.1.12 Weitere Parameter - Bilirubin, anorganisches Phosphat, Creatinin, Cholesterol, γ-Glutamyltransferase (GGT), Glutamatdehydrogenase (GLDH) 66 4.5.2 Auswertung der Stoffwechselparameter in Bezug auf den Klauenscoreanstieg 67 4.5.2.1 Korrelationen zum Klauenscoreanstieg 67 4.5.2.2 Energiestoffwechselparameter bei Tieren innerhalb des Referenzbereiches und Tieren außerhalb des Referenzbereiches in der 1.Woche postpartum 68 4.5.2.2.1 Freie Fettsäuren (FFS) 68 4.5.2.2.2 ß-Hydroxybutyrat (BHB) 69 4.5.2.2.3 Glucose 70 4.5.2.2.4 Lactat 71 5 DISKUSSION 72 5.1 Beurteilung der Fütterung 72 5.2 Subklinische Klauenrehe und klinische Lahmheit 72 5.2.1 Subklinische Klauenrehe 72 5.2.2 Lahmheit 73 5.3 Einflüsse von Boden und Haltung auf die Entwicklung einer subklinischen Klauenrehe 74 5.4 Einflüsse von Erkrankungen verschiedener Organsysteme auf die Entwicklung einer subklinischen Klauenrehe 75 5.5 Thermographie 75 5.5.1 Aussagekraft der Thermographie der Klauensohlenoberflächen 75 5.5.2 Temperaturverteilung zwischen den einzelnen 8 Hauptklauen (Vorder- und Hinterklauen jeweils lateral und medial) 76 5.5.3 Unterschiede der Klauentemperaturen zwischen Kühen und Färsen und zwischen den Betrieben 77 5.5.4 Temperaturverteilung innerhalb der einzelnen Hauptklauen – Unterschiede zwischen Klauenspitze und Ballenbereich 78 5.6 Einflüsse der Körperkondition und Körperkonditionsentwicklung auf die Ausbildung einer subklinischen Klauenrehe 79 5.7 Stoffwechsel 79 5.7.1 Änderung der Stoffwechselparameter im Laktationsverlauf 79 5.7.1.1 Eiweißstoffwechsel und Enzyme 79 5.7.1.2 Mineralstoffwechsel 80 5.7.1.2.1 Calcium 80 5.7.1.3 Lactat 80 5.7.1.4 Bilirubin, anorganisches Phosphat, Creatinin, Cholesterol, γ-Glutamyltransferase (GGT), Glutamatdehydrogenase (GLDH) 80 5.7.1.5 Energiestoffwechsel 81 5.7.1.5.1 Freie Fettsäuren (FFS) 81 5.7.1.5.2 ß-Hydroxybutyrat (BHB) 81 5.7.1.5.3 Glucose 81 5.7.2 Energiestoffwechselentgleisung und Einflüsse auf die Entwicklung einer subklinischen Klauenrehe 82 6 ZUSAMMENFASSUNG 83 7 SUMMARY 85 8 LITERATURVERZEICHNIS 87 ANHANG
168

Thermographie et shearographie appliquées au contrôle non-destructif d'interfaces entre de l'adhésif époxy et du CFRP

Théroux, Louis-Daniel 20 April 2018 (has links)
Le sujet de ce mémoire porte sur l'étude du contrôle non-destructif de structure de béton renforcé par collage de CFRP (carbon fiber reinforced polymer) par shearographie et thermographie active couplées. La méthode d'excitation utilisée conjointement lors de la mise en œuvre de ces deux méthodes est un rayonnement thermique conditionné temporellement par un signal carré. L'observation du champ des températures de surface et des déplacements hors plan de la surface permet la détection et la caractérisation de défauts. Dans un premier temps, des tests de faisabilité ont été conduits pour valider si l'utilisation d’une contrainte thermique de type créneau autorisait des mesures shearographiques (cela ayant été déjà validé dans le cas de la thermographie infrarouge active). Cette série de test s’étant avérée concluante, une étude numérique par modélisation aux éléments finis a été réalisée sous Comsol®. Cette étude numérique a permis de mieux appréhender les résultats obtenus expérimentalement mais aussi de conduire une étude de l’influence de différents paramètres. Des outils d'analyses ont été développés et ont permis de mettre en évidence, entre autre, qu'une évaluation quantitative des défauts était possible.
169

Quantitative kinematic and thermal full fields measurement / Mesure quantitative de champs cinématiques et thermiques

Zhang, Chao 05 March 2019 (has links)
La mesure simultanée des champs cinématiques et thermiques est très importante pour les procédures thermomécaniques. Les caméras à base de silicium sont largement utilisées pour l'observation en temps réel des champs cinématiques, principalement grâce à la corrélation d'images numériques. De plus, ils sont aussi connus pour sa sensibilité dans le spectre du proche infrarouge, ce qui permet d’acquérir des champs thermiques à l’aide d’une caméra à base de silicium. Cependant, pour la caméra à base de silicium, il y a deux problèmes principaux d’obtenir simultanément des champs cinématiques et thermiques. D’abord, dans le spectre du proche infrarouge, une petite variation de température entraînera une modification importante du niveau de gris de l'image, ce qui entraînera facilement une mauvaise qualité des images. Deuxième, la corrélation d’images numériques nécessite une surface hétérogène et contrastée, tandis que la thermographie dans le proche infrarouge nécessite une surface homogène et constante. Dans cette thèse, une technique innovante a été proposée pour ajuster automatiquement le temps d'exposition de la caméra afin d'obtenir des images exploitables pour l’analyse cinématique et thermique, quel que soit l'évolution de température à la surface de l'objet observé. Cette technique a été validée par expériences différentes, notamment des expériences de chauffage d’un corps noir et des expériences de chauffage d’un échantillon réel. Les modèles radiométriques du corps noir et de la surface des échantillons calibrent respectivement. Basé sur les modèles radiométriques, des champs thermiques ont été reconstruits sur les images exploitables pour l’analyse cinématique et thermique. L'expérience à haute température est réalisée pour le ballonnement des tubes où les champs cinématiques et thermiques sont observés. La corrélation d'images numériques a été effectuée globalement afin d'obtenir des champs cinématiques. Pour effectuer la thermographie du proche infrarouge sur la surface de l’échantillon, le modèle radiométrique est étalonné selon une partie des pixels les plus brillants. Dans ce cas, 20% des pixels les plus brillants sont utilisés pour effectuer l'étalonnage des modèles radiométriques. Basée sur le modèle en utilisant 20% des pixels plus brillants, les champs thermiques sont reconstruits. Combiné avec les coordonnées connues du champ cinématique par corrélation d'images numériques, le champ thermique et le champ cinématique dans les mêmes coordonnées peut être obtenu. / Simultaneous measurement of kinematic and thermal full fields are very important for thermomechanical procedures. Silicon-based cameras are widely used to perform real-time observation of the kinematic fields, mainly thanks to digital image correlation. Moreover, they are known to be as well sensitive in the near-infrared spectral range, thus the acquirement of thermal fields using silicon-based cameras is possible. However, there are two main problems for the silicon-based camera to obtain simultaneously kinematic and thermal fields. One is that in the near-infrared spectral range, a small temperature variation will lead to a large modification in the image gray level, which easily leads to poor quality images. Another is that digital image correlation needs a heterogeneous and contrasting surface, while the near-infrared thermography needs a homogeneous and constant surface. In this thesis, an innovative technique was proposed to automatically adjust the exposure time of the camera to obtain kinematically and thermally exploitable images whatever the temperature evolution occurs on the surface of the observed object. This technique was validated by different experiments, including blackbody heating experiments and realistic specimen heating experiments. Radiometric models of blackbody and specimen surfaces ware calibrated respectively. Based on the radiometric models, thermal fields have been reconstructed on the kinematically and thermally exploitable images. High temperature tube ballooning experiment is conducted to perform both kinematic and thermal fields. Global digital image correlation was performed to obtain kinematic fields. To perform near-infrared thermography on the specimen surface, radiometric model is calibrated based on portions of the brightest pixels. In this case 20% of the brightest pixels are used to perform radiometric model calibration. Based on the radiometric model using 20% of the brightest pixels, the thermal fields are reconstructed. Combined with the known coordinates of kinematic fields by digital image correlation, the thermal fields at the same coordinates as kinematic fields can be obtained.
170

Crack inspection and simulations with Eddy Current Thermography for the aerospace industry

Tran, Gia Phuong 19 April 2018 (has links)
La Thermographie des Courants de Foucault (Eddy Current Thermography, ECT) est une méthode de contrôle non-destructif (CND) sans contact, et de nos jours il est utilisé dans une large gamme d'applications. Cette méthode combine les techniques de courants de Foucault et des techniques de thermographies de type CND afin de fournir une méthode efficace pour la détection des fissures. Dans cette méthode, le courant de Foucault est généré dans les échantillons métalliques. Si l'échantillon contient des fissures, le déplacement du courant et la propagation de la température à l'intérieur des échantillons métalliques seraient affectés par ces fissures. Les changements de la distribution de température sont captés par une caméra infrarouge. L'un des principaux défis de cette méthode est qu'elle nécessite beaucoup de paramètres dans les expériences, tels que l’excitation des bobines: la valeur de la fréquence, le nombre de tours, le matériel de fil, le rayon de la bobine ... Afin d'optimiser les expériences, la simulation numérique est nécessaire, et le logiciel COMSOL Multiphysics® FEM est une solution très appropriée. Pendant le processus de simulation, une limite de détection de fissure a été proposée pour une fissure dans un spécimen métallique donné. Les résultats de la simulation et de la limite de détection des fissures sont également vérifiés au moyen d’expériences en laboratoire. L'objectif final de cette thèse est de fournir une image globale de la Thermographie des Courants de Foucault, la limite de détection des fissures et la manière dont la simulation ainsi que les expériences doivent être effectue afin de détecter les fissures dans les échantillons de plaques métalliques. Ces échantillons ont été fournis par L3-MAS et Pratt &amp; Whitney Canada (PWC), les partenaires industriels impliqués dans ce projet quia été financé par le Conseil de recherches en sciences naturelles et en génie du Canada (CRSNG) et le Consortium de recherche et d'innovation en aérospatiale au Québec (CRIAQ). / Eddy Current Thermography (ECT) is a non-contact, non-destructive testing (NDT) method, and nowadays it is used in a wide range of applications. This method combines eddy current and thermographic NDT techniques in order to provide an efficient method for crack detection. In this method, the eddy current is generated into metallic specimens. If the specimen contains cracks, the current flow and temperature propagation inside the metallic specimens would be affected by these cracks. The changes of temperature distribution are captured by an infrared camera. One of the main challenges in this method is that it requires many parameters in the experiments, such as coil excitations: the frequency value, number of turns, material of wire, radius of the coil...In order to optimize the experiments, numerical simulation is necessary, and COMSOL Multiphysics® FEM software is a very suitable solution. During the simulation process, a crack detection limit for a crack in a given metallic specimen has been proposed. The simulation results and crack detection limit are also verified using experiments in the laboratory. The final goal of this thesis is to provide the overall picture of the Eddy Current Thermography, crack detection limit and the manner in which to simulate as well as perform the experiments in order to detect cracks on the metallic plate specimens which were provided by L3-MAS and Pratt &amp; Whitney Canada (P.W.C), the industrial partners involved in this project which was sponsored by the Natural Sciences and Engineering Research Council of Canada (NSERC) and The Consortium for Research and Innovation in Aerospace in Québec (CRIAQ).

Page generated in 0.1627 seconds