Spelling suggestions: "subject:"thermographie infrarouge"" "subject:"thermographie unfrarouge""
101 |
Mesure thermographique des effets dissipatifs accompagnant le fretting : d'une construction rapide des cartes d'amorçage vers une meillleure compréhension des mécanismes d'endommagement / Thermographic measurement of dissipative effects under fretting loadings : from a first attempt for a rapid determination of the fretting maps, to a better understanding of the damage mechanismsMoustafa, Abdel Rahman 30 March 2016 (has links)
This study is part of an original approach based on quantitative imaging techniques, such as Infrared Thermography, to study the damage under fretting loadings. The main objective was the establishment of new experimental method for a rapid determination of crack initiation conditions under fretting loadings, based on the analysis of the thermal signal. One other objective was the determination of the different heat sources in order to assess a local analysis of the fretting damage. This work underlined the great potential of Infrared Thermography to study this damage. / Cette étude s'inscrit dans une approche originale basée sur des techniques d'imagerie quantitatives comme la thermographie infrarouge pour étudier l'endommagement sous chargement de fretting. Le premier objectif était de développer une méthode de construction rapide de carte de fretting basée sur l'analyse du signale thermique au cours d'essais de fretting. Un deuxième objectif était de déterminer les sources de chaleurs accompagnant le fretting pour une meilleure compréhension des mécanismes d'endommagement. Ce travail a souligné le grand potentiel de la thermographie infrarouge pour l'étude de c'est phénomènes.
|
102 |
Analyse thermomécanique du comportement cyclique des élastomères par mesure de champs / Thermomechanical analysis of the cyclic behavior of elastomers using full field measurementsSamaca Martinez, José Ricardo 13 December 2013 (has links)
De nombreux phénomènes à l’oeuvre dans le processus de déformation et d’endommagement des élastomères sont étudiés à partir de la réponse mécanique de ces matériaux. Cependant, la plupart de ces phénomènes dépendent de la température et ont des signatures calorimétriques qui pourraient permettre de mieux les comprendre. Dans le contexte industriel de la manufacture de pneumatiques, les élévations de température induites par le chargement peuvent fortement impacter les performances physiques des pneumatiques ainsi que la tenue en fatigue des constituants caoutchoutiques. L’objectif de cette thèse est donc de caractériser le comportement thermomécanique des élastomères chargés et non chargés sous divers types de chargement mécanique. Pour ce faire, des mesures de champs thermiques et cinématiques couplées ont été mises en oeuvre lors d’essais mécaniques à température ambiante. Dans un premier temps, des essais de traction uniaxiale sur éprouvettes indemnes ont permis de confirmer que l’hystérésis mécanique observée lors d’un cycle de traction sur un caoutchouc naturel non chargé est essentiellement due au phénomène de cristallisation et non à des phénomènes dissipatifs. Par ailleurs, la construction de bilans énergétiques sur un cycle mécanique a permis de distinguer la contribution des différents mécanismes dissipatifs (viscosité, effet Mullins) des couplages thermomécaniques (élasticité entropique, cristallisation). Dans un second temps, des essais de cisaillement pur ont été menés sur des éprouvettes préalablement entaillées. Les analyses thermomécaniques menées à l’échelle de la zone d’influence de la fissure ont montré que les phénomènes dissipatifs aux très grandes déformations ne s’expriment pas de la même manière qu’aux déformations plus faibles. En particulier, pour les mélanges considérés dans cette étude, les effets du couplage entropique et de la viscosité sont du même ordre à la décharge, si bien que le matériau n’absorbe pas de chaleur à la décharge. Ces résultats sont très prometteurs à la fois pour la compréhension des phénomènes physiques impliqués dans le processus de déformation et pour la modélisation du comportement thermomécanique des élastomères. / Usually, most of the physical phenomena involved in the deformation of elastomers are studied from purely mechanical approaches. However, almost all of such phenomena depend on temperature and have distinguishable calorimetric signatures, which can enable us to better understand them. Furthermore, in the tire industrial context, the temperature increase induced by loading and self-heating may strongly impact the physical performances of tires as well as the fatigue life of the rubber components. Consequently, the aim of this PHD thesis was to characterize the thermomechanical behavior of rubbers, filled and unfilled, subjected to different mechanical loadings. For this purpose, coupled thermal and kinetic full field measurements have been performed during mechanical tests at ambient temperature. First, homogeneous uniaxial tensile tests have enabled us to confirm that the hysteresis loop in terms of the stress-strain relationship is mainly induced by crystallization phenomenon in natural rubber, not to dissipative phenomena. In the same way, energetic balances over one mechanical cycle have enabled us to distinguish the contribution of different dissipative phenomena (viscosity, Mullins effect) and the thermomechanical couplings (entropic elasticity, crystallization). Second, the analysis of the pure shear tests with pre-cracked specimens has enabled us to analyze, for the first time, the calorimetric response of rubbers in the zone of crack influence. Results have shown that dissipative phenomena at large strains differ from those involved at smaller strains. More especially, for the materials considered in the present study, the effects of the entropic coupling and viscosity are of the same order of magnitude during unloading, so that the material does not absorb any heat during unloading. These results are promising and motivate further work in this field in order to better understand the physical phenomena involved in the deformation processes as well as to more relevantly model the thermomechanical behavior of elastomers.
|
103 |
Analyse thermomécanique du comportement cyclique des élastomères par mesure de champsSamaca Martinez, José Ricardo 13 December 2013 (has links) (PDF)
De nombreux phénomènes à l'oeuvre dans le processus de déformation et d'endommagement des élastomères sont étudiés à partir de la réponse mécanique de ces matériaux. Cependant, la plupart de ces phénomènes dépendent de la température et ont des signatures calorimétriques qui pourraient permettre de mieux les comprendre. Dans le contexte industriel de la manufacture de pneumatiques, les élévations de température induites par le chargement peuvent fortement impacter les performances physiques des pneumatiques ainsi que la tenue en fatigue des constituants caoutchoutiques. L'objectif de cette thèse est donc de caractériser le comportement thermomécanique des élastomères chargés et non chargés sous divers types de chargement mécanique. Pour ce faire, des mesures de champs thermiques et cinématiques couplées ont été mises en oeuvre lors d'essais mécaniques à température ambiante. Dans un premier temps, des essais de traction uniaxiale sur éprouvettes indemnes ont permis de confirmer que l'hystérésis mécanique observée lors d'un cycle de traction sur un caoutchouc naturel non chargé est essentiellement due au phénomène de cristallisation et non à des phénomènes dissipatifs. Par ailleurs, la construction de bilans énergétiques sur un cycle mécanique a permis de distinguer la contribution des différents mécanismes dissipatifs (viscosité, effet Mullins) des couplages thermomécaniques (élasticité entropique, cristallisation). Dans un second temps, des essais de cisaillement pur ont été menés sur des éprouvettes préalablement entaillées. Les analyses thermomécaniques menées à l'échelle de la zone d'influence de la fissure ont montré que les phénomènes dissipatifs aux très grandes déformations ne s'expriment pas de la même manière qu'aux déformations plus faibles. En particulier, pour les mélanges considérés dans cette étude, les effets du couplage entropique et de la viscosité sont du même ordre à la décharge, si bien que le matériau n'absorbe pas de chaleur à la décharge. Ces résultats sont très prometteurs à la fois pour la compréhension des phénomènes physiques impliqués dans le processus de déformation et pour la modélisation du comportement thermomécanique des élastomères.
|
104 |
Impact de la modélisation physique bidimensionnelle multicellulaire du composant semi-conducteur de puissance sur l'évaluation de la fiabilité des assemblages appliqués au véhicule propreEl Boubkari, Kamal 25 June 2013 (has links) (PDF)
A bord des véhicules électriques (VE) et Hybrides (VEH), les fonctions de tractions sont assurées par des convertisseurs électroniques de puissances. Ces derniers sont constitués de module de puissance (IGBTs ou MOSFETs). Au cours de leur fonctionnement, ces modules sont parfois soumis à de fortes contraintes électriques et thermiques qui amènent à une défaillance ou même à une destruction. Le premier objectif sera de réaliser un banc expérimentale permettant d'étudier le vieillissement des modules IGBTs en régîmes extrêmes de fonctionnement (mode de court-circuit). Ainsi, nous évaluerons les différents indicateurs de vieillissements permettant de prédire la défaillance du composant. Il sera question aussi de suivre le vieillissement ou une dégradation initié sur les composants IGBTs par thermographie infrarouge. Le second objectif sera de modéliser et simuler par éléments finis différentes structures d'IGBTs, afin de valider les modèles en fonctionnement statique et dynamique. L'avantage de l'approche multicellulaire par rapport à l'approche unicellulaire sera mis en avant.
|
105 |
Development of a non contact calorimeter in isoperibolic millifluidic systems using InfraRed Thermography : applied to biphasic flows / Développement d’un calorimètre sans contact pour des systèmes isopériboliques millifluidiques : application aux écoulements diphasiquesRomano Mungaray, Marta 30 October 2013 (has links)
Ce travail porte sur le développement d’une technique de calorimétrie sans contact pour des écoulements diphasiques. Ces derniers sont réalisés sur la forme d’un train gouttes dans des tubes de taille millimétriques dans des supports isopériboliques. L’idée principale est de coupler la Thermographie Infrarouge et les outils microfluidiques pour proposer une technique adapté de mesure. L’utilisation de la microfluidique rend possible l’utilisation de très faibles volumes réactionnels limitant ainsi tout risque lié à la dangerosité des réactions réalisées au sein des gouttes, l’outil Infrarouge permet de suivre ces écoulements avec grande précision. Les résultats de ces travaux de thèse montrent que l’outil est capable d’estimer des propriétés thermo-physiques des écoulements non réactifs. Ainsi, que de caractériser de réactions chimiques en termes d’enthalpie et cinétique. Finalement cette dernière caractérisation a été comparée aux techniques classiques pour mettre en évidence la précision et les avantages de l’outil développé / This work concerns the development of a non-contact calorimeter for two-phase flow characterization. The biphasic flow is performed under a droplet configuration inside millimetric tubings which are inserted into the isoperibolic chip. The main idea is to combine the Infrared Thermography and microfluidic tools to propose a suitable technique for accurate measurements. Microfluidics enables the use of small reaction volumes thus limiting any risk of dangerous reactions inside droplets, the Infrared tool enables to monitor the thermal signature of these flows with high accuracy. The results of this thesis show that this tool is able to estimate the thermophysical properties of non-reactive flows. Also , it is possible to characterize chemical reactions in terms of enthalpy and kinetics . Finally the latter characterization was compared to conventional techniques to demonstrate the benefits and the precision of the tool.
|
106 |
Étude expérimentale du transfert paroi/fluide dans le cas d’un écoulement vertical vapeur/gouttes dans une géométrie tubulaire / Experimental study of wall-to-fluid heat transfer in the case of a steam-droplets flow inside a vertical pipePeña Carrillo, Juan David 10 December 2018 (has links)
L’un des accidents de dimensionnement d’un réacteur à eau pressurisée est l’Accident de Perte de Réfrigérant Primaire (APRP). L’évènement initiateur d’un tel accident est une brèche sur le circuit primaire du réacteur entrainant une perte d’inventaire en eau, et de ce fait conduit à un assèchement des assemblages combustibles. En conséquence, une augmentation considérable de la température surviendrait à l’intérieur du cœur du réacteur. Ainsi, les gaines de combustible peuvent éventuellement se déformer et des zones dites ballonnées apparaitre. Ces zones vont avoir un fort impact sur l’efficacité du refroidissement du cœur du réacteur. Pour contribuer à l’étude thermohydraulique d’un APRP, la présente thèse a pour but la caractérisation expérimentale des interactions entre un écoulement diphasique de vapeur/gouttes et une zone partiellement bouchée. Afin de reproduire un tel scénario, le banc expérimental thermohydraulique COLIBRI a été conçu. Plusieurs configurations géométriques de la zone ballonnée, caractéristiques d’un APRP, sont analysées (longueur et taux de bouchage associés au ballonnement). Afin de caractériser les échanges thermiques paroi/fluide ainsi que la dynamique des gouttes, des diagnostics optiques et thermiques sont utilisés : l’Anémométrie Phase Doppler (PDA) pour mesurer le diamètre et la vitesse des gouttes, la Fluorescence Induite par Laser (LIF) pour mesurer la température des gouttes et la Thermographie Infrarouge (IR) afin d’estimer le flux de chaleur extrait du tube par l’écoulement. En parallèle, une modélisation du problème a été développée afin d’obtenir une approche théorique de la capacité de refroidissement de l’écoulement diphasique. Le système d’équations décrivant la conservation de la masse, de la quantité de mouvement et de l’énergie permettra d’estimer l’impact respectif des différents mécanismes de transferts thermiques mis en jeu ainsi que l’évolution spatio-temporelle des paramètres thermohydrauliques / During a Loss of Coolant Accident (LOCA) in a Pressurized Water Reactor (PWR), caused by a break or a leakage on the primary circuit, partial or even complete drying of the fuel assemblies may occur. In these conditions, the fuel temperature increases, leading to a significant deformation and rupture of the fuel rod cladding. The cooling flow might be impaired, according to the size and distribution of the deformed zones within the fuel assemblies during the emergency cooling phase (Reflooding phase). To contribute to the thermalhydraulic study of the reflooding phase, this study aims to characterize experimentally the coolability of a representative deformed sub-channel by a steam-droplets flow under LOCA conditions. In order to reproduce such a scenario, the experimental thermal-hydraulic set-up COLIBRI was designed. Several geometrical blockage configurations are analyzed (Blockage ratios and axial lengths). Three measurement techniques are set up to follow the cooling transient phase of each experience: Phase Doppler Anemometry (PDA) in order to obtain both velocity and diameter of droplets, Laser Induced Fluorescence (LIF) to measure the mean droplet temperature and Infrared thermography to estimate the heat flux removed by the two-phase flow. Additionally, a one-dimensional mechanistic model, taking into account of the heat transfers mechanisms in the post-dry out region, is developed in order to analyze the experimental data and identify each one of the wall-to-fluid heat transfers (radiation with vapor and droplets, convection with vapor, evaporation, and droplet impact)
|
107 |
Thermique des mini-canaux : comportement instationnaire et approche convolutive / Heat transfer in mini-channels : unsteady behaviour and convolutive approachHadad, Waseem Al 22 September 2016 (has links)
Un modèle semi-analytique permettant de simuler le transfert thermique conjugué dans un mini/macro canal plan soumis à des sources de chaleur surfaciques localisées sur les faces externes et variantes en fonction du temps, a été présenté et vérifié. Plus le diamètre hydraulique du canal est petit, plus la caractérisation expérimentale interne (mesure des températures et des flux) en régime thermique permanent ou transitoire à l'aide des capteurs internes est délicate. Une méthode non-intrusive permettant d'estimer les conditions internes à partir des mesures de température par thermographie infrarouge sur les faces externes et d'un modèle semi-analytique, a été effectuée. Comme le coefficient de transfert convectif forcé classique perd son sens en régime instationnaire, une approche alternative basée sur une fonction de transfert, valable pour un système linaire et invariant dans le temps a été mise en œuvre. Cette fonction peut être calculée analytiquement (uniquement pour une géométrie simple) ou estimée expérimentalement (géométrie complexe). Grâce au caractère intrinsèque de cette fonction de transfert, deux capteurs virtuels ont été conçus : capteur virtuel de température et détecteur d'encrassement permettent respectivement d'estimer les températures internes et de détecter l'encrassement qui peut avoir lieu dans l'échangeur à partir des mesures de températures sur les faces externes / A semi-analytical model allowing to simulate the transient conjugate heat transfer in mini/macro plane channel subject to a heat source(s) localized on the external face(s), was presented and verified. The developed model takes into account advection-diffusion in the fluid and conduction in the solid. As the hydraulic diameter of the channel becomes small, the internal experimental characterization (measurement of temperature and heat flux) using internal sensors become tricky because internal sensors located may compromise the structural integrity of the whole system. A non-intrusive method for estimating the internal conditions from infrared temperature measurements on the external faces using the semi-analytical model was performed. Since the classic convective heat transfer coefficient loses its meaning in transient state, an alternative approach based on a transfer function, valid for Linear Time-Invariant (LTI) systems, was highlighted. This function can be calculated analytically only for a simple geometry. For complex geometries it can be estimated experimentally. Thanks to intrinsic character of this function, two characterization methods were designed. The first to estimate the temperature at a point from a measurement at another point in the system (virtual temperature sensor). The second method concerns the detection of fouling layers that may appear in the heat exchanger from temperature measurements on the external faces
|
108 |
Transferts de chaleur et de masse lors de l’impact d’une goutte sur une paroi chaude en régime d’ébullition en film : application de diagnostics optiques et modélisation / Heat and mass transfert at the impact of a droplet in the film boiling regime : Application of optical diagnostics and modellingChaze, William 31 October 2017 (has links)
La compréhension des phénomènes se déroulant lors de l’impact d’une goutte sur une paroi chaude est essentielle à l’optimisation des systèmes de refroidissement par sprays. Lorsque la température de paroi est élevée, un film de vapeur se forme quasi-instantanément entre la goutte et la paroi chaude. Ce film modifie le comportement hydrodynamique des gouttes et réduit considérablement les échanges de chaleur et de masse par rapport à un impact mouillant. La modélisation de ces phénomènes est complexe en raison des nombreux couplages entre les transferts de chaleur et de masse et la dynamique d’impact de la goutte. Pour aborder ce sujet, des techniques de mesure optiques ont été développées spécifiquement. L’imagerie de fluorescence induite par plan laser à deux couleurs permet de caractériser la distribution de la température à l’intérieur des gouttes. Des images du champ de température, résolues à la fois spatialement et temporellement, sont rendues possible grâce à l’utilisation d’un nouveau couple de colorants fluorescents conservant une grande sensibilité à la température quand ils sont excités par un laser pulsé nanoseconde d’une énergie de plusieurs centaines de mJ. En parallèle, la thermographie infrarouge a été utilisée pour déterminer la température de la surface d’impact en saphir. Pour cela, cette dernière est recouverte d’une couche de quelques centaines de nanomètres de TiAlN, émissif dans l’IR alors que le saphir est transparent. Les images haute cadence sont analysées par un modèle d’inversion, prenant en compte la conduction thermique dans le saphir, afin d’estimer la densité de flux thermique au niveau de la surface d’impact. L’épaisseur du film de vapeur est également déduite de ces mesures sous l’hypothèse, justifiée a posteriori, d’une conduction thermique prépondérante dans le film de vapeur. Une étude de l’impact de gouttes d’eau est réalisée en faisant varier la vitesse d’impact et la température des gouttes avant impact, ainsi que la température de paroi. Dans la plupart des cas, la chaleur extraite à la paroi est comparable à celle transférée au liquide pour l’échauffer. Lorsque la température de paroi se rapproche et dépasse la température de Leidenfrost, les transferts de chaleur deviennent de plus en plus sensibles au nombre de Weber, et de moins en moins dépendant de la température de paroi. L’épaisseur du film de vapeur est affectée par des instabilités, dont les caractéristiques (longueur d’onde, amplitude) sont étudiées à partir des images IR. Finalement, un modèle 1D semi empirique est proposé pour décrire l’échauffement des gouttes et la croissance du film de vapeur. La pression exercée par la goutte sur le film de vapeur se dissipe très vite à l’impact, si bien que la croissance du film de vapeur est gouvernée par la conduction de la chaleur vers la goutte et non par la dynamique de l’impact / The understanding of phenomena occurring at the impact of a droplet onto a hot wall is crucial for the optimization of spray cooling systems. When the temperature of the wall is high, a vapor layer appears quasi-instantaneously between the droplet and le wall. This film of vapor modifies the hydrodynamic behavior of the droplet and highly reduce the heat and mass transfers in comparison with a wetting impact. Modelling these phenomena is complex because of the numerous coupling between the heat and mass transfers and the fluids dynamic. To get some insights into this phenomenon, optical diagnostic techniques have been developed. Two color planar laser induced fluorescence imaging allows characterizing the distribution of the temperature inside the droplet. Images of the temperature fields, resolved both spatially and temporally, are recorded thanks to the use of a couple of fluorescent dyes keeping a high temperature sensitivity even when they are excited by a nanosecond pulsed laser with and an energy of hundreds m J. In parallel, the infrared thermography is used to determine the temperature of the impinged surface made of sapphire. For that, this surface is coated with a thin film (about 300 nanometers) of TiAlN, highly emissive in the IR domain as opposed to the sapphire which is transparent in it. High frame rate image sequences are analyzed thanks to an analytical inversion model, taking into account the thermal conduction in the sapphire, in order to estimate the heat flux density at the impact surface. The thickness of the vapor layer was also deduced from this measurements thanks to the hypothesis of a dominant thermal conduction in the vapor layer. A study of water drop impact was performed with different impact speeds, wall temperatures and different drop injection temperatures. In most of the cases, the heat flux extracted from the wall in close to the flux transferred to the liquid phase of the droplet. When the wall temperature approaches or exceeds the Leidenfrost temperature, the transfers become more sensitive to the Weber number and less sensitive to the wall temperature. The vapor layer thickness is affected by instabilities whose caracteristics (wavelengths, amplitude) were investigated from the IR images. Eventually, a 1-Dsemi-empirical model is given for describing the heating of the liquid part of the droplet and the growth of vapor layer. The effect of the pressure exerted by the droplet onto the vapor film rapidly decreases during the impact process, so that the growth of the vapor film is only driven by the heat transferred by conduction to the droplet and not by dynamical parameters such as the impact velocity
|
109 |
Etude du comportement dynamique des structures composites réalisées par LRI : application à l’impact et à la fatigue / Dynamic behavior of LRI's composite structures : application to impact and fatigueGarnier, Christian 29 November 2011 (has links)
Les industriels du secteur aéronautique sont, de plus en plus, à la recherche de procédés de fabrication à forte valeur ajoutée sans modifier les paramètres d’infusabilité de la résine lorsque l’on change de tissu. Nous avons donc mis en œuvre le procédé d’infusion de résine liquide sur des composites carbone/époxyde de forte épaisseur (e>4 mm) en modifiant les cycles de polymérisation, les matériaux utilisés et les séquences d’empilement. Tous les tissus sont en carbone et la résine utilisée est la résine commerciale RTM6. Les structures aéronautiques sont sollicitées, en service, de différentes façons. Elles peuvent être accidentellement impactées par des engins de maintenance, des outils, de la grêle ou toute autre forme d’impact. Le problème pour les industriels est de pouvoir détecter l’endommagement créé et de comprendre les mécanismes mis en jeu lors de l’impact mais aussi leur évolution pendant un cyclage en fatigue. Nos travaux se sont donc inscrits dans cet objectif et différentes méthodes ont été mises en œuvre : détection de défauts d’impact et suivi en temps réel par thermographie infrarouge, détection de l’indentation résiduelle par numérisation par projection de franges. Parallèlement, le phénomène d’impact a aussi été traité par une étude statistique par plan d’expérience et une modélisation avancée a été créée avec l’utilisation de surfaces cohésives. / Aeronautical manufacturers are looking for the best manufacturing process giving high benefits. Moreover, it has to be implemented easily with change of woven fabrics. So, we realize thick carbon/epoxy composites (t>4 mm) by modifying cure cycles, woven fabrics and lay-up sequences. Concerning the constituent materials of the composites, woven fabrics are carbon made and the resin is the commercial product named RTM6. Aeronautical structures can be unfortunately stressed, in service, with different solicitations: holding, engine impact, falling objects impacts or other way. The main problem for industrials is to be able to detect the created damage, to understand the phenomena dealing with it and the damage evolution during fatigue cycles. By following this direction, different methods are developed: impact damage defects detection and evolution monitored with infrared thermography, impact residual depth measurement by fringes projection digitalization. At the same time, a statistical study made by design of experiments is completed. A numerical impact modeling is also developed by using cohesive surfaces.
|
110 |
Système microfluidique à onde élastique de surface : vers la duplication d'ADN par PCR / Microfluidic system using surface acoustic wave : Toward the DNA amplification by PCRRoux-Marchand, Thibaut 02 December 2013 (has links)
Un système microfluidique à onde élastique de surface a été développé dans le but de réaliser une réaction d'amplification de brins d'ADN par PCR. Nous avons principalement étudié la température et l'uniformité de l'échauffement des gouttes irradiées par des ondes de type Rayleigh. Ces dernières sont générées à la surface d'un substrat piézoélectrique de Niobate de Lithium (LiNbO3). Nous avons pensé un système consommant le moins d'énergie électrique possible pour atteindre les températures désirées et permettant une meilleure uniformité de la température des gouttes. Pour cela, un dispositif à transducteur enterré a été réalisé sous une couche isolante de silice. Les gouttes sont ainsi directement posées sur le transducteur ce qui limite les pertes et améliore la répartition de la chaleur au sein des gouttes. Nous avons ensuite vérifié que les réactifs de la PCR ne sont pas affectés par les ondes de Rayleigh ce qui laisse présager que la PCR peut être réalisée à l'aide d'un système d'échauffement par ondes de Rayleigh. Par ailleurs, le déplacement de goutte sur ce type de substrat de LiNbO3 est important pour des applications de type laboratoire sur puce. Ce substrat ayant des propriétés hydrophiles, des revêtements ont été développés afin de minimiser la force nécessaire à l'actionnement des gouttes. Dans ces travaux, nous proposons un nouveau type de couche à base de copolymère P(VDF-TrFe) dont la fabrication est simplement réalisée par dissolution et étalement par spin-coating. Nous avons montré que ce type de couche n'affecte que très peu la propagation des ondes de Rayleigh et les propriétés hydrophobes sont équivalentes à d'autres revêtements / In this work, a microfluidic system based on surface acoustic wave has been developed in order to achieve the amplification of DNA strands by temperature cycling (PCR). We studied mainly the temperature and the heat uniformity of microdroplets irradiated by Rayleigh waves. These waves are generated at the surface of a lithium niobate substrate. We propose a system allowing better temperature uniformity within microdroplets with an optimal energy consumption. For this, a device with buried transducer has been developed under an insulating layer (Silice). The droplets are then placed directly on the transducer which limits losses and improves the distribution of heat within the microdroplets. We then verified that the PCR reagents are not affected by the Rayleigh waves which suggests that PCR can be performed using a heating system by Rayleigh waves. Moreover, the move of microdroplets on this kind of LiNbO3 substrate is important for lab on chip applications. This substrate having hydrophilic properties, some coatings have been developed to minimize the required force to actuate the microdroplets. In this work, we developed a new hydrophobic layer based on copolymer P(VDF-TrFe) whose production is simply made by dissolving and spreading by spin-coating. We have shown that this kind of layer is compatible with Rayleigh waves and that the hydrophobic properties are equivalent to other coatings
|
Page generated in 0.0488 seconds