• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 82
  • 10
  • 8
  • 6
  • 5
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 118
  • 118
  • 118
  • 34
  • 27
  • 16
  • 14
  • 13
  • 12
  • 11
  • 11
  • 10
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

A novel method for incorporating periodic boundaries into the FDTD method and the application to the study of structural color of insects

Lee, Richard Todd 29 May 2009 (has links)
In this research, a new technique for modeling periodic structures in the finite-difference time-domain (FDTD) method is developed, and the technique is applied to the study of structural color in insects. Various recent supplements to the FDTD method, such as a nearly-perfect plane-wave injector and convolutional perfectly matched layer boundary condition, are used. A method for implementing the FDTD method on a parallel, distributed-memory computer cluster is given. To model a periodic structure, a single periodic cell is terminated by periodic boundary conditions (PBCs). A new technique for incorporating PBCs into the FDTD method is presented. The simplest version of the technique is limited to two-dimensional, singly-periodic geometries. The accuracy is demonstrated by comparing to independent results calculated with a frequency-domain, mode-matching method. The periodic FDTD method is then extended to the more general case of three-dimensional, doubly-periodic problems. This extension requires additional steps and imposes new limitations. The computational cost and limitations of the method are presented. Certain species of butterflies exhibit structural color, which is caused by quasi-periodic structures on the scales covering the wings. Numerical experiments are performed to develop a technique for modeling quasi-periodic structures using the periodic FDTD method. The observed structural color of butterflies is then calculated from the electromagnetic data using colorimetric theory. Three types of butterflies are considered. The first type are from the Morpho genus. These are typically a brilliant, almost metallic, blue color. The second type is the Troides magellanus, which exhibits an interplay of structural and pigmentary color, but the structural color is only visible near grazing incidence. The final type is the Ancyluris meliboeus, which exhibits iridescence on the ventral side. For all cases, the effects of changing the dimensions of various structural elements are considered. Finally, some earlier work on the design of TEM horn antennas is presented. The TEM horn is a simple and popular antenna, but only limited design information is available in the literature. A parametric study was performed, and the results are given. A complete derivation of the characteristic impedance of the basic antenna is also presented.
102

Analise no dominio do tempo de estruturas eletromagneticas utilizando elementos finitos vetoriais e ortogonais / Time-domain analysis of electromagnetic structures using vectorial and orthogonal finite elements

Gonçalves, Marcos Sérgio, 1973- 27 February 2007 (has links)
Orientadores: Aldario Chrestani Bordonalli, Hugo Enrique Hernandez Figueroa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-09T17:10:22Z (GMT). No. of bitstreams: 1 Goncalves_MarcosSergio_D.pdf: 5511725 bytes, checksum: 912286218aecf274afdc63d4eb68d0b5 (MD5) Previous issue date: 2007 / Resumo: Este trabalho apresenta uma nova formulação para a simulação da propagação de campos eletromagnéticos no domínio do tempo em duas e três dimensões. Os algoritmos desenvolvidos incorporam a discretização por elementos finitos e usam as funções de base de arestas ortogonais em duas e, pela primeira vez, em três dimensões para descrever o comportamento de propagação dos campos elétrico e magnético em diferentes estruturas. Tais funções são baseadas nos elementos de arestas de Whitney e preservam as mesmas características que as funções de bases de arestas convencionais. Com o uso destas funções de bases, obtêm-se, naturalmente, matrizes massas diagonais, eliminando-se, por completo, a resolução, a cada passo temporal, do sistema matricial resultante dos métodos convencionais, resultando em um alto desempenho no processamento de dados. Os campos são analisados no domínio do tempo através do método da envoltória, modelado pela equação de onda vetorial, sendo a principal aplicação o estudo de componentes fotônicos / Abstract: This work presents a new approach for the simulation of the time-domain electromagnetic fields in two and three dimensions. The developed algorithms incorporate finite-element discretization and make use of two- and three-dimension orthogonal edge basis functions to describe the electric and magnetic fields. Such functions are based on the Whitney¿s edge elements and preserve the same characteristics as those of the conventional edge basis functions. With the use of these basis functions, solution of diagonal mass matrices appear naturally, eliminating, at each time step, the matrix equations that result from conventional methods and producing a high performance data processing. The fields are analyzed in time-domain using the slow-wave method, modeled by the vector wave equation. The study of photonic components is the main application of this method / Doutorado / Telecomunicações e Telemática / Doutor em Engenharia Elétrica
103

Resposta temporal de vigas com vibro-impacto utilizando modelos de força de contato / Time response of beams with vibro-impact using contact force models

Ferreira, Luan Jose Franchini, 1987- 22 August 2018 (has links)
Orientador: Alberto Luiz Serpa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-22T21:32:28Z (GMT). No. of bitstreams: 1 Ferreira_LuanJoseFranchini_M.pdf: 31334961 bytes, checksum: 0c668b476e8b23fc3d0c578acdda9020 (MD5) Previous issue date: 2013 / Resumo: O vibro-impacto de vigas ocorre devido ao contato intermitente das estruturas na presença de folgas, gerando desgaste excessivo, vibração com grandes amplitudes, falhas prematuras de componentes e altos níveis de ruído. A determinação da resposta no domínio do tempo do sistema, ou seja, deslocamentos, velocidades e acelerações, juntamente com os esforços de contato são de fundamental importância para o projeto desses sistemas, na prevenção de falhas e no controle de vibrações e ruído. Foi desenvolvido um código utilizando a linguagem MATLAB que a partir dos dados de uma malha de elementos finitos de viga, determina a resposta dinâmica da viga sobre a condição de vibro-impacto. A resposta dinâmica foi obtida utilizando a integração numérica da equação do movimento discretizada. Os métodos de integração numérica da diferença centrada, Newmark e alpha-HHT foram implementados para o caso de contato intermitente e utilizados na determinação da resposta dinâmica da estrutura. A condição de contato intermitente originada pelo processo de vibro-impacto foi tratada avaliando a condição de não penetração dos corpos nos instantes de tempo específicos definidos pelo intervalo de tempo utilizado na integração numérica. Os modelos de contato mecânico utilizados foram os modelos de força de contato proporcional e o cúbico / Abstract: The vibro-impact of beams occurs due to intermittent contact of the structures in the presence of clearances, generating excessive wear, vibration with large amplitudes, premature failure of components and high noise level. A MATLAB code was developed using the finite element model of the beam, obtaining the dynamic response of the beam with the vibro-impact condition. The dynamic response was obtained using numerical integration of the discretized equation of motion. The numerical integration method of the central difference, Newmark and alpha-HHT were implemented for the case of contact and used for the determination of the structure time response. The contact condition caused by vibro-impact process was treated evaluating the condition of nonpenetration bodies in specific instants of time defined by the numerical integration method. The mechanical contact models proportional force and cubic force were used / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
104

Etude de la régulation de température d'un milieu fini homogène diffusif et incertain à l'aide des trois générations de la commande CRONE / Study of temperature regulation of a diffusive and uncertain homogeneous medium using the three generations of the CRONE command

Christophy, Fady 15 December 2016 (has links)
Le contrôle de la température d'un milieu thermique reste d'une grande importance en raison du coût économique qu'il peut engendrer. Ainsi, un moyen efficace de réduire les coûts de chauffage/refroidissement est de fournir un bon système de contrôle qui limite l'énergie nécessaire pour exécuter ces tâches. À cette fin, nous étudierons le contrôle d'une interface diffusive homogène finie utilisant le contrôleur CRONE de trois générations et contrôlons leurs comportements. La nouveauté de ce travail existe dans l'utilisation d'un contrôleur de commande fractionnaire (le contrôleur CRONE) appliqué à une unité d'ordre fractionnaire et l'utilisation d'un contrôleur complexe (la troisième génération) qui n'est pas si familier dans le domaine des contrôleurs. Les résultats montrent le comportement et la robustesse des contrôleurs CRONE de trois générations. / Controlling thermal medium’s temperature remains of a great importance, because of the economic cost that it may engender. Thus, one effective way to reduce heating/cooling cost is by providing a good control system that limits power needed to run these tasks. For this purpose, we will study the control of a finite homogeneous diffusive interface using the three generations CRONE controller and control their behaviors. The novelty of this work exists in the use of a fractional order controller (the CRONE controller) applied to a fractional order plant and the use of a complex controller (the third generation) which is not so familiar in the controllers domain. The results show the behavior and the robustness of the three generations CRONE controllers.
105

Maximum likelihood time-domain beamforming using simulated annealing

Xu, Kevin January 1999 (has links)
Thesis (S.M.)--Joint Program in Oceanographic Engineering (Massachusetts Institute of Technology, Dept. of Ocean Engineering; and the Woods Hole Oceanographic Institution), 1999. / Bibliography: p. 111-112. / by Kevin Xu. / S.M.
106

Design, Fabrication, And Testing Of High-transparency Deep Ultra-violet Contacts Using Surface Plasmon Coupling In Subwavelength Aluminum Meshes

Mazuir, Clarisse 01 January 2011 (has links)
The present work aims at enhancing the external quantum efficiencies of ultra-violet (UV) sensitive photodetectors (PDs) and light emitting diodes (LEDs)for any light polarization. Deep UV solid state devices are made out of AlGaN or MgZnO and their performances suffer from the high resistivity of their p-doped regions. They require transparent p-contacts; yet the most commonly used transparent contacts have low transmission in the UV: indium tin oxide (ITO) and nickel-gold (Ni/Au 5/5 nms) transmit less than 50% and 30% respectively at 300 nm. Here we investigate the use of surface plasmons (SPs) to design transparent p-contacts for AlGaN devices in the deep UV region of the spectrum. The appeal of using surface plasmon coupling arose from the local electromagnetic field enhancement near the metal surface as well as the increase in interaction time between the field and semiconductor if placed on top of a semiconductor. An in/out-coupling mechanism is achieved by using a grating consisting of two perpendicularly oriented sets of parallel aluminum lines with periods as low as 250 nm. The incident light is first coupled into SPs at the air/aluminum interface which then re-radiate at the aluminum/AlGaN interface and the photons energy is transferred to SP polaritons (SPPs) and back to photons. High transmission can be achieved not only at normal incidence but for a wider range of incident angles. iv A finite difference time domain (FDTD) package from R-Soft was used to simulate and design such aluminum gratings with transparency as high as 100% with tunable peak wavelength, bandwidth and angular acceptance. A rigorous coupled wave analysis (RCWA) was developed in Matlab to validate the FDTD results. The high UV transparency meshes were then fabricated using an e-beam assisted lithography lift-off process. Their electrical and optical properties were investigated. The electrical characterization was very encouraging; the sheet resistances of these meshes were lower than those of the conventionally used transparent contacts. The optical transmissions were lower than expected and the causes for the lower measurements have been investigated. The aluminum oxidation, the large metal grain size and the line edge roughness were identified as the main factors of inconsistency and solutions are proposed to improve these shortcomings. The effect of aluminum oxidation was calculated and the passivation of aluminum with SiO2 was evaluated as a solution. A cold deposition of aluminum reduced the aluminum grain size from 60 nm to 20 nm and the roughness from 5 nm to 0.5 nm. Furthermore, replacing the conventional lift-off process by a dry back-etch process led to much smoother metal line edges and much high optical transparency. The optical measurements were consistent with the simulations. Therefore, reduced roughness and smooth metal line edges were found to be especially critical considerations for deep UV application of the meshes.
107

Computation of Specific Absorption Rate in the Human Body due to Base-Station Antennas using a Hybrid Formulation

Abd-Alhameed, Raed, Excell, Peter S., Mangoud, Mohab A. January 2005 (has links)
A procedure for computational dosimetry to verify safety standards compliance of mobile communications base stations is presented. Compared with the traditional power density method, a procedure based on more rigorous physics was devised, requiring computation or measurement of the specific absorption rate (SAR) within the biological tissue of a person at an arbitrary distance. This uses a hybrid methd of moments/finite difference time domain (MoM/FDTD) numerical method in order to determine the field or SAR distribution in complex penetrable media, without the computational penalties that would result from a wholly FDTD simulation. It is shown that the transmitted power allowed by the more precise SAR method is, in many cases, between two and five times greater than that allowed by standards implementing the power flux density method.
108

The use of steady-state level combinations and signal event edge correlations in the disaggregation of total power measurements

Penn, Joseph J January 2015 (has links)
A dissertation submitted to the Faculty of Engineering and the Built Environment, University of the Witwatersrand, Johannesburg, in ful lment of the requirements for the degree of Master of Science in Engineering. Johannesburg, 2015 / The work presented extends and contributes to research in Non-Intrusive Load Monitoring (NILM), focussing on steady-state and transient power measurement disaggregation techniques for circuits containing household ap- pliances. Although previous work in this area has produced and evaluated a wide range of NILM approaches, much of it has involved the use of datasets captured from real-world household implementations. In such cases, the lack of accurate ground truth data makes it di cult to assess disaggregation tech- niques. In the research presented, three NILM techniques are comparatively evaluated using measurements from typical household appliances assembled within a laboratory environment, where accurate ground truth data could be compiled to complement the measurements. This allows for the accu- racy of the various disaggregation approaches to be precisely evaluated. It is demonstrated that the correlation of transient event edges in aggregated power measurements to individual appliance transient exemplars performs better than the matching of steady-state power levels against individual ap- pliance state combinations. Furthermore, the transient approach is shown to be the most appropriate technique for further development. / MT2017
109

Localização de faltas incipientes em sistemas de distribuição de energia elétrica com cabos subterrâneos

Herrera-Orozco, Andrés Ricardo January 2017 (has links)
Nos sistemas de distribuição de alta e média tensão tem-se aumentado a utilização de linhas de distribuição de energia subterrâneas ou cabos subterrâneos. A ocorrência de faltas nas linhas afeta negativamente a qualidade da energia e o correto funcionamento da rede. O processo que leva a uma falta nos cabos é gradual e está caracterizado por uma série de subciclos de faltas incipientes associadas a uma tensão de arco. Estas, muitas vezes, passam despercebidas e, eventualmente, resultam em uma falta permanente. Os métodos clássicos de localização de faltas como as metodologias baseadas no cálculo da impedância aparente, as baseadas na inteligência artificial e as baseadas nas ondas viajantes são, habitualmente, aplicadas ao sistema depois de uma falta permanente acontecer e precisam de um ou mais ciclos do sinal para entregar uma resposta razoável. No entanto, as faltas nos cabos são um processo gradual, de curta duração (entre ¼ e ½ ciclo do sinal) e seria desejável localizar a falta incipiente antes de tornar-se permanente. Nesse contexto, esta pesquisa aborda o problema de localização de faltas incipientes. Assim, nesta tese propõe-se uma nova técnica de localização de faltas incipientes usando medições em um terminal, no domínio do tempo e que utiliza componentes de fase. Desta forma, são desenvolvidas duas novas formulações do modelo elétrico do sistema de distribuição com cabos subterrâneos durante uma falta incipiente. A abordagem proposta considera simultaneamente na sua formulação características da falta incipiente e dos sistemas de distribuição de energia, como a tensão de arco, o modelo Π nominal de parâmetros concentrados do cabo subterrâneo, o desequilíbrio do sistema e a condição da carga. A estimativa da distância da falta, junto com os parâmetros da falta incipiente, é obtida a partir da solução de um sistema sobredeterminado de equações lineares pela aplicação do método de mínimos quadrados ponderados não negativos. As formulações propostas permitem estimar a distância da falta em termos da reatância da linha até a falta. Além disso, é proposto um processo de compensação de corrente para estimar a corrente de falta; é aplicado um pré-processamento dos dados de entrada para suavizar o efeito do ruído que pode conter o sinal e, é aplicado um pós-processamento dos resultados para refinar e entregar a melhor estimativa obtida durante o processo de localização da falta. O desempenho da técnica proposta é avaliado mediante estudos de casos simulados em um circuito real de distribuição no Alternative Transients Program (ATP/EMTP) considerando análises de sensibilidade e comparativa. Também, o modelo da falta incipiente foi programado utilizando a ferramenta de MODELS do ATP/EMTP. Os resultados obtidos, considerando faltas incipientes simuladas que avaliam a influência da variação da magnitude de tensão de arco, do ruído aleatório inserido na tensão de arco, da distância da falta, da taxa de amostragem, do carregamento do sistema, do modelo de tensão de arco e de incertezas nas medições, indicam claramente que a abordagem proposta possui validade como técnica de localização de faltas incipientes, apresentando erros médios globais de 1,60% e 0,93%, respectivamente para cada formulação proposta. / The use of underground power distribution lines or underground cables in the high and medium voltage distribution systems has increased dramatically in recent years. The fault occurrence in the distribution lines negatively affects the power quality and the correct network operation. The process which leads to a fault in underground cables is gradual and is characterized by a series of sub-cycles of incipient faults associated with an arc voltage. These often are unnoticed and, eventually, results in a permanent fault. Classical fault localization methods such as the based-impedance, the based on artificial intelligent and the based on traveling waves are, usually, applied to the system after a permanent fault occurrence and need one or more signal cycles for providing a reasonable response. However, the faults in cables are a gradual process, with short duration (between ¼ to ½ of signal cycle) and would be desirable to locate the fault before this becomes a permanent fault. In this context, this research approaches the incipient faults location problem. Thus, in this thesis is proposed a new incipient fault location technique using single-end terminal measurement, in time-domain and employing phase components. In this way, two new formulations of the electrical model of the distribution system with underground cables during an incipient fault are developed. The proposed approach considers simultaneously in its formulation, incipient fault type and power distribution systems characteristics as arc voltage, unbalanced operation, load conditions and complete line model. The fault distance estimation, together with the incipient fault parameters, it is obtained from the solution of an overdetermined linear system of equations by the application of the non-negative weighted least squares estimator method. The proposed formulations allow estimating the fault distance in terms of the line reactance up to the fault. In addition, a load current compensation strategy is proposed to reduce its effect in the fault current estimation; an input data pre-processing is applied to smooth out the noise effect and a post-processing of the results is performed for estimation refinement and to provide the best estimate obtained during the fault location process. The proposed technique performance is evaluated through simulated cases studies in a real-life distribution network with underground cable data in the Alternative Transients Program (ATP/EMTP) considering sensitivity and comparative analyzes. Also, the fault model was programmed using the MODELS tool of ATP/EMTP. The obtained results, considering simulated incipient faults, which evaluate the influence of variations in the arc voltage magnitude, random noise percentage inserted in the arc voltage, fault distance, sampling rate, load dynamics, the arc voltage model and uncertainties in measurements, indicate clearly that the proposed approach is valid as incipient faults location technique, showing overall average errors of 1,60% and 0,93%, respectively for each proposed formulation.
110

Localização de faltas incipientes em sistemas de distribuição de energia elétrica com cabos subterrâneos

Herrera-Orozco, Andrés Ricardo January 2017 (has links)
Nos sistemas de distribuição de alta e média tensão tem-se aumentado a utilização de linhas de distribuição de energia subterrâneas ou cabos subterrâneos. A ocorrência de faltas nas linhas afeta negativamente a qualidade da energia e o correto funcionamento da rede. O processo que leva a uma falta nos cabos é gradual e está caracterizado por uma série de subciclos de faltas incipientes associadas a uma tensão de arco. Estas, muitas vezes, passam despercebidas e, eventualmente, resultam em uma falta permanente. Os métodos clássicos de localização de faltas como as metodologias baseadas no cálculo da impedância aparente, as baseadas na inteligência artificial e as baseadas nas ondas viajantes são, habitualmente, aplicadas ao sistema depois de uma falta permanente acontecer e precisam de um ou mais ciclos do sinal para entregar uma resposta razoável. No entanto, as faltas nos cabos são um processo gradual, de curta duração (entre ¼ e ½ ciclo do sinal) e seria desejável localizar a falta incipiente antes de tornar-se permanente. Nesse contexto, esta pesquisa aborda o problema de localização de faltas incipientes. Assim, nesta tese propõe-se uma nova técnica de localização de faltas incipientes usando medições em um terminal, no domínio do tempo e que utiliza componentes de fase. Desta forma, são desenvolvidas duas novas formulações do modelo elétrico do sistema de distribuição com cabos subterrâneos durante uma falta incipiente. A abordagem proposta considera simultaneamente na sua formulação características da falta incipiente e dos sistemas de distribuição de energia, como a tensão de arco, o modelo Π nominal de parâmetros concentrados do cabo subterrâneo, o desequilíbrio do sistema e a condição da carga. A estimativa da distância da falta, junto com os parâmetros da falta incipiente, é obtida a partir da solução de um sistema sobredeterminado de equações lineares pela aplicação do método de mínimos quadrados ponderados não negativos. As formulações propostas permitem estimar a distância da falta em termos da reatância da linha até a falta. Além disso, é proposto um processo de compensação de corrente para estimar a corrente de falta; é aplicado um pré-processamento dos dados de entrada para suavizar o efeito do ruído que pode conter o sinal e, é aplicado um pós-processamento dos resultados para refinar e entregar a melhor estimativa obtida durante o processo de localização da falta. O desempenho da técnica proposta é avaliado mediante estudos de casos simulados em um circuito real de distribuição no Alternative Transients Program (ATP/EMTP) considerando análises de sensibilidade e comparativa. Também, o modelo da falta incipiente foi programado utilizando a ferramenta de MODELS do ATP/EMTP. Os resultados obtidos, considerando faltas incipientes simuladas que avaliam a influência da variação da magnitude de tensão de arco, do ruído aleatório inserido na tensão de arco, da distância da falta, da taxa de amostragem, do carregamento do sistema, do modelo de tensão de arco e de incertezas nas medições, indicam claramente que a abordagem proposta possui validade como técnica de localização de faltas incipientes, apresentando erros médios globais de 1,60% e 0,93%, respectivamente para cada formulação proposta. / The use of underground power distribution lines or underground cables in the high and medium voltage distribution systems has increased dramatically in recent years. The fault occurrence in the distribution lines negatively affects the power quality and the correct network operation. The process which leads to a fault in underground cables is gradual and is characterized by a series of sub-cycles of incipient faults associated with an arc voltage. These often are unnoticed and, eventually, results in a permanent fault. Classical fault localization methods such as the based-impedance, the based on artificial intelligent and the based on traveling waves are, usually, applied to the system after a permanent fault occurrence and need one or more signal cycles for providing a reasonable response. However, the faults in cables are a gradual process, with short duration (between ¼ to ½ of signal cycle) and would be desirable to locate the fault before this becomes a permanent fault. In this context, this research approaches the incipient faults location problem. Thus, in this thesis is proposed a new incipient fault location technique using single-end terminal measurement, in time-domain and employing phase components. In this way, two new formulations of the electrical model of the distribution system with underground cables during an incipient fault are developed. The proposed approach considers simultaneously in its formulation, incipient fault type and power distribution systems characteristics as arc voltage, unbalanced operation, load conditions and complete line model. The fault distance estimation, together with the incipient fault parameters, it is obtained from the solution of an overdetermined linear system of equations by the application of the non-negative weighted least squares estimator method. The proposed formulations allow estimating the fault distance in terms of the line reactance up to the fault. In addition, a load current compensation strategy is proposed to reduce its effect in the fault current estimation; an input data pre-processing is applied to smooth out the noise effect and a post-processing of the results is performed for estimation refinement and to provide the best estimate obtained during the fault location process. The proposed technique performance is evaluated through simulated cases studies in a real-life distribution network with underground cable data in the Alternative Transients Program (ATP/EMTP) considering sensitivity and comparative analyzes. Also, the fault model was programmed using the MODELS tool of ATP/EMTP. The obtained results, considering simulated incipient faults, which evaluate the influence of variations in the arc voltage magnitude, random noise percentage inserted in the arc voltage, fault distance, sampling rate, load dynamics, the arc voltage model and uncertainties in measurements, indicate clearly that the proposed approach is valid as incipient faults location technique, showing overall average errors of 1,60% and 0,93%, respectively for each proposed formulation.

Page generated in 0.0532 seconds