• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1015
  • 29
  • 28
  • 28
  • 28
  • 27
  • 17
  • 11
  • 5
  • 4
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1068
  • 564
  • 280
  • 216
  • 190
  • 129
  • 127
  • 111
  • 103
  • 97
  • 89
  • 87
  • 81
  • 77
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Avaliação in vitro da dureza superficial de uma resina acrilica para microondas e rugosidade da mesma e de duas ligas metalicas quando submetidas a agentes quimicos de limpeza

Souza Junior, Joane Augusto de 19 September 2001 (has links)
Orientador: Renata C. M. Rodrigues Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T22:47:16Z (GMT). No. of bitstreams: 1 SouzaJunior_JoaneAugustode_M.pdf: 4774819 bytes, checksum: 9266daf23fd3dbe4444a1989bf160542 (MD5) Previous issue date: 2001 / Resumo: Foi propósito deste trabalho avaliar a dureza superficial de uma resina acrílica polimerizada por energia de microondas, bem como a rugosidade desta mesma resina e de duas ligas metálicas: Co-Cr e Ti-6Al-4V, quando imersas em duas soluções de limpeza de próteses. Foram confeccionadas 48 amostras de resina Onda-Cryl contendo uma barra metálica exposta em uma das faces. Oito amostras contendo a liga de Co-Cr foram imersas em solução limpadora Polident (GI), oito em solução de limpeza confeccionada em farmácia de Manipulação (G2), e oito em água (Controle - G3); o mesmo se repetindo para amostras contendo a liga de Ti-6Al-4V (G4, G5 e G6, respectivamente). Todas as amostras foram mantidas em saliva artificial à 37°C e imersas nas respectivas soluções de limpeza durante 5 minutos, 3 vezes ao .dia. As avaliações da dureza e rugosidade foram realizadas imediatamente após o polimento das amostras (TO), e após 1 (TI), 15 (T2) e 30 dias (T3). A dureza superficial foi avaliada em microdurômetro Shimadzu HMV -200 e a rugosidade em rugosímetro Surfcorder SE 1700. Os resultados foram submetidos à análise estatística e demonstraram que: a) para a dureza da resina acrilica houve diferenças significantes para os grupos GI e G4 nos tempos TI e T3 (14,028::t2,784; I4,056::tI,76I) e grupo G2 e G5 no tempo T2 (I6,992::t2,243); b) para a rugosidade da resina acrílica os resultados diferiram para os grupos GI e G4 nos tempos T2 e T3 (0,I44::tO,062; 0,209::tO,383); c) para a rugosidade na liga de Co-Cr, o grupo G2 (0,1O4::tO,035) diferiu dos demais grupos no tempo TI; e o grupo GI (0,I48::tO,OI6) diferiu dos demais grupos nos tempos T2, e no tempo T3 todos os grupos diferiram entre si; e d) para a rugosidade na liga de Ti-6Al-4V, o grupo G4 diferiu dos demais grupos nos tempos T2 (0,lI9::tO,OO5) e T3 (0,lO8::tO,O37). Com relação às ligas, o grupo G3 (0,083i:0,018) diferiu de G6 no tempo TO, e o grupo G6 (2,354i:0,767) diferiu de G3 no tempo T3. Concluí-se que o agente químico de limpeza Polident diminui a dureza da resina acrílica e não interfere na rugosidade desta e das ligas estudadas, e que o limpador de Manipulação aumenta a rugosidade em ambos os materiais estudados / Abstract: The aim of this study was to evaluate the Knoop hardness and roughness of microwave acrylic resin and the roughness of two metal alloys: Co-Cr and Ti-6Al-4V when immersed into two denture cleansers. Forty-eight samples of Onda-Cryl acrylic resin were made with a metallic bar exposed in one side. Eight samples with Co-Cr alloy were immersed in denture cleanser Polident (G 1 ), eight in denture cleanser made in Manipulation pharmacy (G2), and eight in water (Control) (G3); the same procedure was repeated with Ti-6Al-4V samples (G4, G5 and G6, respectively). All samples were kept in synthetic saliva at 37°C and immersed in the soIutions during 5 minutes, 3 times a day. The Knoop hardness and roughness were verified immediately after polishing (TO), and after 1 (TI), 15 (T2), 30 (T3) days.' The Knoop hardness was evaluated using microhardness Shimadzu IIl / Mestrado / Protese Dental / Mestre em Clínica Odontológica
362

Influência das temperaturas de cocção de porcelanas no desajuste cervical de copings em titânio comercialmente puro e ligas titânio-alumínio-vanádio e paládio-prata

Fonseca, Johnson Campideli 28 July 2018 (has links)
Orientador : Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T00:39:18Z (GMT). No. of bitstreams: 1 Fonseca_JohnsonCampideli_M.pdf: 12216850 bytes, checksum: 6238e2e5911c70a5790792f791e70d48 (MD5) Previous issue date: 2001 / Resumo: A utilização do titânio e suas ligas em prótese tem aumentado nos últimos anos do conjunto de propriedades físico-químicas que exibem, sendo escassas as >rmaçôes a respeito da adaptação cervical de restaurações fundidas. Este estudo objetivou: 1) determinar o desajuste cervical de copings fundidos em comercialmente puro (Ti c.p.) e iigas titánio-aiumínio-vanádio (ÏÎ-6AI-4V) e paládio-prata (Pd-Ag); 2) avaliar a influência do ciclo de cocção das porcelanas preconizadas sobre o desajuste cervical dos copings fundidos em Ti c.p. e ligas TÍ-6A1-4V e Pd-Ag; 3) avaliar a aneíusão) sobre o desajuste cervical dos copings fundidos em Ti c.p. e bga TÏ-6A1-4V. s típicos para restaurações as {altura de 5mm; término cervical em ombro 90° e largura de l,5mm; erimentais Ti-óAMV, TÍ-6A1-4V com tratamento térmico (TÍ-6A1-4V TT), Ti c.p.. Ti érmico (Ti c.p. TT) e Pd-Ag. Os copings em Ti c.p. e liga TÍ-6A1-4V pelo sistema Rematitan (Dcntaurum). O tratamento térmico experimental s TÍ-6A3-4V TT e Ti c.p. TT) foi realizado nas inclusões originais à temperatura do aquecimento da porcelana (800°C). O desajuste cervical tbi medido com auxilio metidos à Análise de Variância (ANOVA) e teste de Tukey, com nível de probabilidade 5%. Os valores médios de desajuste cervical obtidos ao final dos ciclos de cocção 78um para TÍ-6A1-4V, 86,02 urn para TÍ-6A1-4V TT, 117,22um para Ti c.p., para Ti c.p. TT e 9S,70um para Pd-Ag, sem que houvesse diferença significativa entre tais valores. O desajuste cervical dos grupos m Ti c.p. e TÍ-6AÍ-4V não foi influenciado de forma significante pelo ciclo de cocção da porcelana Vitatitankramic. O grupo Pd-Ag mostrou alternação estatisticamente significativa apos a cocção da porcelana para dentina e glaze / Abstract: The application of titanium and titanium alloys in prosthetic dentistry has increased in the past few years because of their physical and chemical properties; however, few studies have investigated the marginal fit of cast restorations. This study evaluated: 1) the marginal fit of copings obtained in commercially pure titanium (c.p. Ti), thanium-aluminurn-vanadiurn (Ti-6A1-4V) and palladium-silver (Pd-Ag) alloys; 2) the influence of firing cycle of recommended porcelains in the marginal fit of c.p. Ti, Ti-6A1-4V and Pd-Ag alloys; 3) the effectiveness of additional heating at the first temperature of firing cycle in the marginal fit of Ti c.p. and Ti-6A1-4V copings. Fifty bovine teeth with standardized preparations for metal-ceramic crowns (length of 5mm; axial taper of 8°; shoulder of 1,5mm) were used and divided in T1-6A1-4V, Ti-6A1-4V with additional heat (Ti-6A1-4V TT), Ti c.p., Ti c.p. with additional heat (Ti c.p. TT) and Pd-Ag experimental groups. The copings for commercially pure titanium and titanium-aluminum-vanadium alloy were obtained in Rematitan System (Dentaurum). The experimental additional heat (Ti-6Ai-4V TT and Ti c.p. TT) was performed in original invested castings at first tiring porcelain temperature (800°C). The marginal fit was measured with the use of a measuring microscope (Olympus STM). The mean values of copings marginal fit were subjected lo analysis of variance (AN OVA) and Tukey's test with statistical significance set at the 5% probability level. The mean values of marginal fit after the complete firing cycle were: 106,78nm to Ti-6AI-4V, 86,02um to Ti-6AI-4V TT. 117,22fim to Ti c.p,, 115,71 um Ti c.p. TT and 98,70um to Pd-Ag, with no significant differences between these experimental groups. The marginal fit of Ti c.p. and Ti-6A1-4V was not significant influenced by Vitalitankeramic firing cycle. The Pd-Ag group revealed significant changes in marginal fit after firing of dentin porcelain and glaze / Mestrado / Materiais Dentarios / Mestre em Odontologia
363

Preparação e testes cataliticos com o catalisador do tipo Ziegler TiCl4/TiO2red. suportado em silica gel

Souza, Jose Luis de 28 July 2018 (has links)
Orientador: Ulf F. Schuchardt / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-28T10:01:18Z (GMT). No. of bitstreams: 1 Souza_JoseLuisde_D.pdf: 2915243 bytes, checksum: e971f7d0b7969cef9d410e81441c2c1f (MD5) Previous issue date: 2001 / Doutorado
364

Analise quimica, microestrutural e da interface implante : pilar intermediario de quatro sistemas de implantes dentarios endo-osseos

Bastos, Eider Guimarães 31 July 2001 (has links)
Orientador: Jose Ricardo de Albergaria-Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-29T04:19:35Z (GMT). No. of bitstreams: 1 Bastos_EiderGuimaraes_D.pdf: 3499152 bytes, checksum: 47ebe25d555010721e86d081d89a4ed4 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar a composição química, metalográficas, a topografia superficial e a interface de adaptação implante pilar intermediário por meio de microscopia óptica, microscopia eletrônica de varredura e espectroscopia de energia dispersiva de quatro sistemas de implantes dentários endoósseos disponíveis no Brasil: Implamed@, Master Screw@, Titanium Fix@ e INP@, divididos em grupos 1, 2, 3 e 4. Os resultados obtidos com a análise química mostraram que todos os grupos apresentaram uma estrutura de titânio comercialmente puro de grau 1. A análise metalográfica mostrou que os quatro grupos apresentaram uma estrutura de fase a+ 13, com o grupo 1 apresentando menor tamanho de grãos. Os resultados obtidos com a microscopia eletrônica de varredura mostraram melhor acabamento nos grupos 1 e 2, com os grupos 3 e 4 mostrando roscas mais afiladas e irregulares, respectivamente. A análise por meio da microscopia eletrônica de varredura e espectroscopia de energia dispersiva mostrou a presença de contaminantes de superfície em todas as amostras. A análise da interface implante-pilar intermediário variou de acordo com o forma geral todos os grupos analisados apresentaram bons resultados, valendo sistema de implante, mas de uma forma geral todos os grupos apresentaram uma boa adaptação entre os componentes. Podemos concluir que de uma ressaltar o bom desempenho dos grupos 1 e 2 nos quesitos de avaliação metalográfica para o tamanho de grãos e acabamento na região das roscas / Abstract: The purpose of this study was to evaluate the chemical composition, metallography, the surface topographies and the abutment-implant interface by means of optic microscopy and scanning electron microscopy with energy dispersive spectroscopy of four dental implant systems available in Brazil: Implamed@, Master Screw@, Titanium Fix@ e INP@, divided in groups 1, 2, 3 e 4. The results obteined by chemical analysis showed that all groups had one typical structure of commercially pure titanium degree 1. The metallography analysis showed the four groups with structutre of a+ phase, and the group 1 with smaller grains. The results obtained by scanning electron microscopy showed better finish of the groups 1 and 2, with the groups 3 and 4 showing spirals more fine and irregulars, respective. The analysis by scanning electron microscopy with energy dispersive spectroscopy showed contaminants of the surface on all samples. The evaluation of the abutment implant interface varied according to the implant, but all the groups showed good adaptation. We conclude that all the groups showed good results, emphasizing the good performance of the groups 1 and 2 in the metallography analysis to grain size and finish of the spirals / Doutorado / Cirurgia / Doutor em Clínica Odontológica
365

Adição de nucleofilos a ions oxocarbenio ciclicos derivados de y-Lactois 5-Substituidos. Formação diastereosseletiva de sistemas tetraidrofuranicos 2,5-trans- e 2,5-cis-Dissubstituidos

Riatto, Valeria Belli 31 July 2018 (has links)
Orientador: Ronaldo Aloise Pilli / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-31T15:00:01Z (GMT). No. of bitstreams: 1 Riatto_ValeriaBelli_D.pdf: 9441024 bytes, checksum: fa73ca0b5dbf0779ba367c6c6a550e0c (MD5) Previous issue date: 2001 / Doutorado
366

Desenvovimento de um verniz a base de tetrafluoreto de titanio e avaliação da estabilidade quimica e atividade anticarie / Development of a tetrafluoride varnish and evaluation of its chemical stability and anticaries activi

Nobrega, Carolina Bezerra Cavalcanti 18 February 2008 (has links)
Orientadores: Pedro Luiz Rosalen, Jaime Aparecido Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-10T19:59:00Z (GMT). No. of bitstreams: 1 Nobrega_CarolinaBezerraCavalcanti_D.pdf: 1384170 bytes, checksum: 6f00a2ed1860ff0108f677f076626e64 (MD5) Previous issue date: 2008 / Resumo: O uso de fluoreto tem sido a principal medida para o controle da cárie dentária. Dentre os compostos químicos utilizados, encontra~se o tetrafluoreto de titânio (TiF4); entretanto, o uso do TiF4 tem sido limitado devido a sua instabilidade em solução aquosa. Desta forma, o objetivo deste trabalho foi desenvolver um verniz à base de tetrafluoreto de titânio (2,26% de fluoreto), avaliar sua estabilidade química e sua eficácia como agente anticárie. A avaliação da estabilidade química foi realizada por espectroscopia de ressonância magnética nuclear utilizando 19F (RMN - 19F), para identificação e quantificação dos subprodutos à base de titânio encontrados no verniz fresco e após teste de envelhecimento. Adicionalmente, a reatividade do verniz fresco e envelhecido foi determinada pela quantificação de fluoreto fracamente (fluoreto de cálcio) e fortemente (fluorapatita) formados no esmalte dental. O potencial anticárie do verniz foi avaliado utilizando o modelo de cárie animal. Quatro grupos com 12 ratas Wistar SPF cada receberam nos molares aplicação do verniz a base de TiF 4 envelhecido por um ano, verniz Duraphat@ (controle positivo - 2,26% de fluoreto), vemiz sem princípio ativo (controle negativo), ou não receberam tratamento e foram submetidas a alto desafio cariogênico por 4 semanas. O efeito anticárie foi avaliado por meio de análise da incidência e da severidade de cárie e da composição da microbiota oral. Ao término do experimento, tecidos da cavidade oral das ratas foram removidos para análise do potencial de toxicidade local ~o verniz. A análise por RMN identificou no verniz desenvolvido seis subprodutos, que se mantiveram estáveis pelo prazo de envelhecimento testado. A capacidade do verniz em formar fluorapatita no esmalte manteve-se estável durante o envelhecimento (p>O,05), mas houve redução na formação de fluoreto de cálcio (pO,05). Não foram identificadas alterações teciduais da cavidade oral na avaliação toxicológica. Os resultados sugerem que o verniz de tetrafluoreto de titânio desenvolvido pode ser considerado uma formulação promissora como agente anticárie / Abstract: Fluorine has been used as the main alternative to control dental caries. A large number of chemical compounds are available for that purpose as titanium tetrafluoride (TiF4); however, TiF4 use has been limited due to its instability in aqueous solutions. In this way, the aim of this study was to develop a titanium tetrafluoride varnish (2.26% fluorine) and evaluate its in vitro chemical stability and anti-caries activity in rats. To evaluate the varnish chemical properties 19F nuclear magnetic resonance spectroscopy C9F-NMR) was used to identify and quantify titanium sub-products in fresh and aged varnishes. Additionally, the reactivity of fresh and aged varnishes was evaluated by quantifying fluoride, loosely (calcium fluoride) and firmly (fluorapatite) formed on dental enamel. To evaluate the anti-caries potential of the titanium tetrafluoride varnish, a caries animal model was used. Wistar SPF rats were randomly assigned to 4 groups (n=12) receiving 'on molars application of aged TiF4 varnish, Duraphat@ varnish (positive control- 2.26% fluorine), non fluoride varnísh (negative control) or no treatment and then submitted to a cariogenic challenge for 4 weeks. The varnish anti-caries effect was evaluated by incidence and severity of dental caries and oral biofilm composition. After the experimental períod, oral tissues of the rats were removed to analyze the local toxic effect of the varnish. Six titanium sub-products of the varnlsh were identified through NMR analysis and kept stable over the aging period. Deposition of fluorapatite on enamel ""as not changed during aging period (p>O.05); however, a reduction in calciumfluoride formation was verified (pO.05). No oral tissue alterations were verified by toxicological analyses. This new'TiF4 formulation might be considered a promising anti-caries agent / Doutorado / Cariologia / Doutor em Odontologia
367

Analise de parametros de influencia na microestrutura e propriedades de ligas Ti-M0-Zr aplicadas em proteses ortopedicas / Analysis of influence parameters on microstructure and properties of Ti-M0-Zr alloys applied in orthopedic implants

Cardoso, Flavia Farias 31 July 2007 (has links)
Orientadores: Rubens Caram Junior, Peterson Luis Ferrandini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-11T09:53:59Z (GMT). No. of bitstreams: 1 Cardoso_FlaviaFarias_M.pdf: 5351739 bytes, checksum: a5e09817ce0f3948835333eeef72cc9d (MD5) Previous issue date: 2007 / Resumo: O presente trabalho analisa parâmetros de influência na microestrutura e propriedades de ligas de titânio tipo ß contendo Mo e Zr aplicadas na confecção de próteses ortopédicas. As ligas de titânio tipo ß apresentam baixo módulo de elasticidade, o que é benéfico para os tecidos ósseos próximos ao implante e também, podem ser concebidas a partir de metais biocompatíveis. O presente trabalho envolveu a avaliação de ligas do sistema Ti-Mo-Zr em relação à estabilidade de fases visando a fabricação de implantes ortopédicos. Dentro desse contexto, em uma etapa inicial, avaliou-se o efeito da composição e da taxa de resfriamento a partir do campo ß na estabilidade de fases e formação da microestrutura, na dureza Vickers e no módulo de elasticidade de ligas Ti-Mo. Em seguida, avaliou-se o efeito de tratamentos térmicos de envelhecimento na microestrutura das ligas Ti-Mo e finalmente, o efeito da adição de Zr na supressão da precipitação da fase ? em ligas Ti-Mo. O trabalho foi implementado a partir da preparação de ligas em forno a arco sob atmosfera controlada, deformação plástica das amostras através de forjamento rotativo e laminação, tratamentos térmicos sob diferentes condições e caracterização utilizando-se microscopia óptica e eletrônica de varredura, difração de raios- X, ensaios de dureza Vickers e análise térmica diferencial. Os resultados obtidos permitiram identificar condições de formação de fases estáveis e metaestáveis, incluindo as fases martensíticas e fase ?. Observou-se que a liga Ti-15Mo resfriada em água apresentou o menor valor de módulo de elasticidade dentre as composições analisadas, 77 GPa, que a fase ? pode ser eliminada após tratamentos térmicos de envelhecimento e que a adição de 8% de Zr a liga Ti-10Mo inibiu a formação da fase ? atérmica sob resfriamento em água, sem que isso modificasse de maneira significativa seu comportamento elástico / Abstract: This work presents an analysis of microstructure and mechanical properties of ß titanium alloys with additions of Mo and Zr, aiming the fabrication of orthopedic implants. The ß titanium alloys can be composed only by biocompatible elements and also present low Young's modulus, which is interesting for the health of the bone surrounding the implant. On the purpose of studying phase stability of Ti-Mo-Zr alloys, the effect of cooling rate when cooling from the ß field and the effect of composition on the microstructure, Vickers hardness and Young¿s modulus of Ti-Mo alloys were initially studied. Afterwards the effect of aging on the microstructure and the effect of Zr additions on the precipitation of ? phase in Ti-Mo alloys were also evaluated. The alloys were arc melted under an argon atmosphere, the ingots were hot swaged and hot rolled and the samples were conveniently heat treated. Characterization involved optical microscopy, scanning electron microscopy, X-ray diffraction, Vickers hardness and differential thermal analysis. The results allow one to identify the conditions of formation of stable and metastable phases, these latter ? and martensites. It was observed that the alloy Ti-15Mo, when water cooled presents 77 GPa, the lowest value of Young¿s modulus, the ? phase may be eliminated by means of aging and that the addition of 8% Zr to the alloy Ti-10Mo completely suppresses formation of the athermal ? phase without affecting significantly its elastic behaviour / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
368

Avaliação dos efeitos promovidos pela aplicação do TiF4 sobre a dentina humana erodida / Evaluation of the effects promoted by TiF4 application on eroded human dentin

Taís Fonseca Mantilla 19 April 2018 (has links)
A prevalência da erosão dental tem aumentado dentre diversas populações e tratamentos capazes de prevenir o desenvolvimento ou controlar a progressão das lesões existentes vem sendo investigados. Dados da literatura recente reportam que a utilização de fluoretos para estas finalidades promove resultados positivos, principalmente quando os compostos contém cátions metálicos polivalentes associados ao fluoreto, como é o caso do tetrafluoreto de titânio (TiF4). Entretanto, sua aplicação clínica ainda não é possível, devido à falta da definição de protocolo ideal, que envolvem fatores que podem influenciar a proteção conferida pelo produto à superfície dental. O objetivo desta tese foi contribuir com o estabelecimento de um protocolo eficiente, mesmo sob a ação dos fatores modificadores presentes na cavidade bucal. Este trabalho apresenta um compilado de cinco estudos laboratoriais, apresentados na forma de capítulos. Nos estudos in vitro, foram utilizadas amostras de dentina radicular humana para avaliar os efeitos causados pela variação da concentração, veículo e pH dos produtos fluoretados sobre a perda de superfície após ciclagem erosiva. Os resultados nortearam posterior estudo in situ que testou, sob as condições presentes na cavidade bucal, a efetividade do tratamento no controle da erosão. Adicionalmente, determinou-se o grau de oclusão tubular gerado pela aplicação do gel de TiF4. Concluiu-se que composições contendo alta concentração de TiF4, em seu pH original e em veículos de mais alta substantividade, permitem significativa redução do processo de erosão, tendo sido capazes de desacelerar a progressão das lesões. Além disso, a camada ácidoresistente formada sobre a superfície dental se mantém após severa ciclagem erosiva/abrasiva e pode promover efeitos adicionais como a obliteração parcial da entrada dos túbulos dentinários. / The prevalence of dental erosion has increased among several populations and treatments capable of preventing the development or controlling the progression of existing lesions have been investigated. Recent literature data report that the use of fluoride for these purposes promotes positive results, especially when the compounds contain polyvalent metal cations associated with fluoride, such as titanium tetrafluoride (TiF4). However, its clinical application is not yet possible, due to the lack of definition of an ideal protocol, which involves factors that may influence the protection achieved by the product on the dental surface. The aim of this thesis was to contribute to the establishment of an efficient protocol, even under the action of modifying factors present in the oral cavity. This paper presents a compilation of five laboratorial studies, presented in the form of chapters. In the in vitro studies, human root dentin samples were used to evaluate the effects caused by the variation of concentration, excipient and pH of the fluoride products on the surface loss after erosive cycling. The results guided a subsequent in situ study which tested, under the conditions present in the oral cavity, the treatment effectiveness on the erosion control. Additionally, the degree of tubular occlusion generated by TiF4 gel application was determined. It was concluded that compositions containing a high concentration of TiF4, in their original pH and in excipients with higher substantivity, allow a significant reduction of the erosion process, being able to decelerate the lesions progression. Besides, the acid-resistant layer formed on the dental surface remains after severe erosive/abrasive cycling and may promote additional effects, such as partial obliteration of the dentinal tubules entrances.
369

Estudo dos micromecanismos de deformação e fratura da liga de Titânio Ti-6AI-4V utilizando-se técnicas de microscopia eletrônica e difração de Raios- X / Study of deformation and fracture micromechanisms of titanium alloy Ti-6Al-4V using electron microscopy and X-ray difraction techniques

Aparecido Edilson Morcelli 18 December 2009 (has links)
A realização do presente trabalho permitiu o estudo dos micromecanismos de deformação e fratura da liga de titânio Ti-6Al-4V, utilizada comercialmente para a fabricação de biomateriais metálicos. As técnicas empregadas para a análise do material em estudo foram: microscopia eletrônica de varredura (MEV), microscopia eletrônica de transmissão (MET) e a difração de raios X (DRX). Estudar a influência e comportamento das diversas fases existentes em ligas de titânio é importante para se avaliar o comportamento de trincas nas ligas de titânio com alta resistência mecânica, que possuem microestrutura fina, relacionando a presença das fases alfa (α), beta (β) e alfa+beta (α+β) com a resistência do material. A avaliação in situ dos micromecanismos de deformação e fratura foi realizada por MET e também foi feito o estudo das transformações de fase durante o resfriamento em ligas de titânio, por MET, utilizando-se as técnicas de campo claro, campo escuro e difração de elétrons (DEAS), em área selecionada. Após tratamento térmico foram observadas as diferenças entre a quantidade das fases α e β, em relação à microestrutura original do material para diferentes condições utilizadas no tratamento térmico aplicado à liga metálica. Observou-se a presença da microestrutura lamelar, formada durante o resfriamento no campo β, promovendo a transformação de parte da estrutura alfa secundária em beta, que se encontrava retida entre as lamelas de alfa. / This present work allowed the study of deformation and fracture micromechanisms of titanium alloy Ti-6Al-4V, used commercially for the manufacture of metallic biomaterials. The techniques employed for the analysis of the material under study were: scanning electron microscopy (SEM), transmission electron microscopy (TEM) and X-ray diffraction (XRD). The study of the influence and behavior of the phases present in titanium alloys is important to evaluate the behavior of cracks in titanium alloys with high mechanical strength, which have fine alpha (α), beta (β) and alpha+beta (α+β) microstructure, linking the presence of the phases with the strength of the material. The evaluation in situ of deformation and fracture micromechanisms were performed by TEM and was also a study of phase transformations during cooling in titanium alloys, using the techniques of bright field, dark field and diffraction of electrons in the selected area. After heat treatment differences were observed between the amount of in relation to the original microstructure of the β and α phases material for different conditions used in heat treatment applied to the alloy. The presence of lamellar microstructure formed during cooling in the β field was observed, promoting the conversion of part of the secondary alpha structure in β phase, which was trapped between the lamellar of alpha.
370

Avaliação de massa e rugosidade superficial de pastilhas de Ti-6Al-4V com aplicação de nanopartículas de prata submetidos ao teste de escovação / Evaluation of mass and surface roughness of Ti-6Al-4V tablets with silver nanoparticles application submitted to brushing test

Vinícius Rizzo Marques 09 December 2015 (has links)
Este estudo teve por objetivo avaliar a variação da massa e rugosidade de pastilhas de Ti-6Al-4V com e sem aplicação superficial de nanopartículas de prata coloidal (BSafe®) de dimensões 1,5 cm; 0,5 cm e 0,2 cm, submetidas à teste de escovação e imersão pelo período experimental de 10 anos. No teste de escovação, quinze espécimes de Ti-6Al-4V (TE), quinze com B-Safe® (BE) e quinze de PMMA (PE) como controle foram subdivididos em três condições de escovação: dentifrício comum (DC), dentifrício experimental (DE) e controle com água destilada (H2O) por 200 mil ciclos em máquina de escovação. Os resultados foram submetidos ao teste ANOVA a 2 critérios (condição de escovação e ciclos) e teste de Tukey (α=0,05) para comparações múltiplas. Foi observada variação de massa apenas quando a condição de escovação foi DC nos espécimes do grupo PE e TE. Houve diferença estatisticamente significante nos valores da variação de rugosidade no grupo TE e PE quando a condição de escovação foi DC; no grupo BE, houve diferença quando a condição foi DC e DE, porém em DE houve redução dos valores médios. No teste de imersão, objetivando analisar a ação dos dentifrícios sem o atrito das cerdas, seis espécimes de Ti-6Al-4V (TI) e seis com B-Safe® (BI) foram subdivididos em três condições de imersão: DC, DE e H2O pelo período de 244 horas. Os resultados foram submetidos ao teste t de student pareado. Não foi observada diferença estatística entre as variações de massa e rugosidade de nenhum dos corpos de prova após o teste. Complementar aos ensaios, foi realizado um protocolo de desinfecção com terapia fotodinâmica com azul de metileno pelo período de 4 semanas nos espécimes escovados. Após todos os testes, foi realizada espectrometria de energia dispersiva de raios-X (EDS) para caracterização dos elementos químicos presentes nos espécimes, onde não se observou variações. Os resultados sugerem que o DE é mais indicado para utilização com implantes, enquanto DC apresenta um poder abrasivo capaz de danificar a superfície do Ti-6Al- 4V. Não foi observado nenhum indício de corrosão em nenhum grupo testado. / This study aimed to evaluate the variation of mass and roughness of Ti-6Al-4V tablets with and without superficial application of colloidal silver nanoparticles (BSafe®) with dimensions of 1,5 cm; 0,5 cm and 0,2 cm, submitted to brushing and immersion test for an experimental period of 10 years. For the brushing test, fifteen specimens of Ti-6Al-4V (TE), fifteen with B-Safe® (BE) and fifteen of PMMA (PE) as control were subdivided into three brushing conditions: normal toothpaste (DC), experimental toothpaste (DE) and control with distilled water (H2O) by 200 thousand cycles in brushing machine. The results were submitted to the ANOVA test on 2 criteria (brushing condition and cycles) and the Tukey test ((α= 0,05) for multiple comparisons. Mass variation was observed only when the brushing condition was DC, in PE and TE groups. Statistically significant difference was observed in the values of roughness variation on TE and PE group when the brushing condition was DC; in the BE group, there was difference when the condition was DC and DE, however in DE there was reduction of the average values. In the immersion test, aiming to analyze the action of toothpastes without the friction of the bristles, six specimens of Ti-6Al-4V (TI) and six with B-Safe® (BI) were subdivided into three immersion conditions: DC, DE and H2O for a period of 244 hours. The results were submitted to paired student t-test. No statistical difference was observed between mass and roughness variation for any of the specimens after the test. Additional to the tests, a disinfection protocol with photodynamic therapy with methylene blue was performed for a 4-week period on the brushed specimens. After all tests, Energydispersive X-ray Spectroscopy (EDS) was performed for characterization of the chemical elements present in the specimens, in which no variations were observed. The results suggest that DE is most suitable for use with implants, while DC has a higher abrasive power capable of damaging the Ti-6Al-4V surface. There was no evidence of corrosion in any tested group.

Page generated in 0.0402 seconds