Spelling suggestions: "subject:"poner"" "subject:"toner""
1 |
Investigation of toner adhesion in the electrophotographic process /Zhou, Hongben. January 2008 (has links)
Zugl.: Erlangen, Nürnberg, University, Diss., 2008.
|
2 |
Gloss and gloss variations inelectrophotographic print = Glans och glansvariationer i elektrofotografiskt tryckHansson, Mikael January 2007 (has links)
This degree project was performed at M-real Technology Centre in Örnsköldsvik. The perpose was to investigate thedifferences in gloss and gloss variations between chemical and ground toner and different paper grades in electrophotographicprints. Gloss is a property that gives the impression of a higher quality of a product. Therefore it is of great importance toaccomplish high gloss in advertising print.A test chart was printed on three different uncoated paper grades on three different printers. Thereafter, gloss, glossvariation, surface topography, print mottle and density were measured. A visual evalution was also performed. A multivariateanalysis was acheived of the data in order to find correlations between the measured variations.The results showed that paper grades with large surface roughness gave more variations in surface topography and glossvariations (both visual and measured) in print. A rough surface also gave more print mottle. Ground toner gave moresurface topography variations and mottle which increased with the amount of silicone used.
|
3 |
Charge acquisition by xerographic materialsHallett, Martin David January 1999 (has links)
No description available.
|
4 |
Modeling and simulation of an electrostatic image transferHoffmann, Rainer. Unknown Date (has links)
Techn. University, Diss., 2004--München.
|
5 |
Desenvolvimento de metodologia de baixo custo para determinação de glifosato usando microdispositivos eletroforéticos fabricados em poliéster-toner / Development of low cost methodology for determination of glyphosate using electrophoretic microdevices fabricated in polyester-tonerSilva, Eduardo Rodrigues da 15 April 2011 (has links)
Um grande crescimento no interesse por microdispositivos eletroforéticos tem sido observado nos últimos anos. Vantagens atrativas como baixo consumo de reagentes e diminutos tempos de analise são verificados. Microdispositivos fabricados usando toner de impressora e folhas de transparência (poliéster) vem a somar valores como baixo custo e simplicidade de confecção à técnica de micro-separação eletroforética. Entretanto, a aplicação analítica utilizando esse tipo de microdispositivo tem sido pouco explorada. <br />Neste trabalho o uso de microchips eletroforéticos fabricados em poliéster-toner (PT) é utilizado para a determinação simultânea do herbicida glifosato e seu maior metabólito, AMPA (ácido aminometilfosfônico). Em um primeiro momento, o trabalho apresenta o desenvolvimento de uma metodologia no qual utiliza condutometria sem contato (C4D) como sistema de detecção, aliada à separação eletroforética em microchips de PT. Vários parâmetros que regem uma boa confiabilidade analítica, tanto quanto otimizam a sensibilidade do sistema foram avaliados. <br />Em um segundo momento, ainda aliada à microchips de PT, a técnica de cronoamperometria foi utilizada como sistema de detecção. Nessa etapa do projeto estudos eletroquímicos foram inicialmente realizados em eletrodos convencionais de ouro e cobre, buscando averiguar qual metal apresenta maior sensibilidade para o herbicida glifosato. Tendo o metal cobre como melhor escolha, eletrodos planares foram construídos a partir da combinação das tecnologias da produção de máscaras de toner, e placas de circuito impresso como fonte de cobre. <br />Em ambas as metodologias desenvolvidas, picos bem resolvidos foram encontrados para os analitos em estudo. Tempos menores que 80 s foram gastos entre o processo de separação e detecção; uma boa repetibilidade também foi encontrada. Os valores de limite de detecção (LD) utilizando C4D foram 60,8 e 74,8 µmol L-1 para glifosato e AMPA respectivamente. Como esperado, menores valores de LD foram obtidos na detecção amperométrica, com 1,88 µmol L-1 para glifosato e 16,45 µmol L-1 para AMPA. A aplicabilidade dos métodos foi verificada através da analise do herbicida e seu metabólito em amostras de água. Etapas de derivatização e pré-concentração off-line não foram usadas nesse trabalho, dessa forma os dois métodos desenvolvidos apresentaram como principais vantagens o extremo baixo custo, e a simplicidade de uso. / A large increase in interest in electrophoretic microdevices has been observed in recent years. Advantages attractive as low reagent consumption and low analytical time are checked. Microdevices fabricated using printer toner and polyester transparency sheets are the sum values as low cost and simplicity of the technique of making micro-electrophoretic separation. However, the analytical application using this type of microdevice has been little explored. <br />In this work the use of microchip electrophoresis fabricated on polyester-toner (PT) is used for the simultaneous determination of the herbicide glyphosate and its major metabolite, AMPA (aminomethylphosphonic acid). In a first moment, the work presents the development of a methodology in which the use capacitively coupled contactless conductivity detection (C4D) for determination of analytes is employed, coupled with electrophoretic separation in PT microchips. Several parameters that govern a good analytical reliability and with the intuit of optimizing the sensitivity of the system were evaluated. <br />In a second time and still allied to the PT microchips, the technique of chronoamperometry was used for detection. Electrochemical studies were initially conducted in conventional electrodes of gold and copper, looking for determine which metal is more sensitive to detect the herbicide glyphosate. Having the best choice planar copper electrodes were constructed from a combination of technologies for the production of toner masks, and printed circuit boards. <br />In both, C4D and chronoamperometric detection methodologies, well-resolved peaks were found for the glyphosate and AMPA. Time analysis of less than 80s were found including the separation and detection processes, and a good analytical repeatability was also found. The limits of detection (LOD) using C4D were 60,8 and 74,8 µmol L-1 respectively for glyphosate and AMPA. As expected, lower LOD were obtained in the amperometric detection methodology, 1.9 µmol L-1 for glyphosate, and 16.5 µmol L-1 for AMPA. The applicability of the methods was tested by analyzing the herbicide and its metabolite in fortified water samples. Steps of derivatization and preconcentration off-line were not applied in this work, so the two methods showed as main advantages very low cost and time analysis, and simplicity of application.
|
6 |
Desenvolvimento de vaso sanguíneo biomimético em plataforma microfluídica de poliéster-toner (PT) / Endothelial cell culture under perfusion on a polyester-toner microfluidic deviceLeão, Paulo Augusto Gomes Garrido Carneiro 21 October 2016 (has links)
O desenvolvimento de dispositivos microfluídicos biomiméticos, \"órgãos-em-chip\", tem permitido melhores respostas em ensaios que carecem de uma correlação fisiológica mais próxima da in vivo. Explorando as tecnologias da microfluídica e microfabricação, esses dispositivos recapitulam aspectos específicos de estruturas e funções dos órgãos. Ainda, os avanços obtidos em culturas tridimensionais de células, modelos de matrizes extracelulares e tecnologias direcionadas às células tronco, têm consolidado os órgãos-em-chip como uma ferramenta fundamental para a compreensão de diversas respostas biológicas do corpo humano frente às aplicações biomédicas, farmacêuticas, químicas e ambientais. Com os avanços da nanotecnologia e ciência dos materiais, inúmeros progressos têm sido alcançados na farmácia e na medicina. Devido à redução da escala, propriedades que se diferenciam substancialmente daquelas encontradas na escala macro são obtidas. As nanopartículas de dióxido de titânio (NPs TiO2) têm apresentado múltiplas aplicações na medicina e na indústria. Em vista disso, faz-se necessário a investigação dos efeitos tóxicos dessas nanopartículas, seja na saúde ou no meio ambiente. É bem documentado que as NPs TiO2 podem chegar à corrente sanguínea e alcançar vários órgãos, causando reações inflamatórias e interações celulares que podem ser patogenicamente relevantes. Assim, o presente trabalho propõe o estudo dos efeitos das NPs TiO2 em células endoteliais (HUVEC) cultivadas em um dispositivo microfluídico fabricado em poliéster-toner (PT), uma tecnologia simples que alia rapidez e baixo custo de produção. A viabilidade do uso dos microchips de PT foi avaliada por meio do teste MTT e produção de NO e verificou-se serem adequados para a cultura de células endoteliais. As células no sistema microfluídico foram expostas às NPs TiO2, e os resultados comparados a um sistema estático (placas de cultura de células) submetido às condições semelhantes. Os sobrenadantes de ambos os sistemas foram utilizados para determinação da produção de VEGF-A. Ademais, foram avaliadas a produção de aníon superóxido e a indução de apoptose. Os resultados esclarecem os mecanismos de toxicidade das NPs TiO2 e são correlacionados com as patologias que eventualmente estão associadas a esses efeitos. Por meio deste estudo, demonstrou-se o grande potencial dos microchips de PT para estudos em biologia celular, os quais podem fornecer a base para ensaios pré-clinicos com maior poder preditivo, alternativos ao uso de animais e cobaias na pesquisa científica. / The development of biomimetic microfluidic devices, \"organ-on-chips\", has allowed better responses in assays that need a closer in vivo physiological correlation. Exploring the technologies of microfluidics and microfabrication, these devices recapitulate specific aspects of structures and functions of the organs. In addition, the progress made in 3D cell cultures, extracellular matrix models, and stem cells technologies, have consolidated the organ-on-chips as a key tool for understanding various biological responses of the human body in face of biomedical, pharmaceutical, chemical, and environmental applications. With the advances in nanotechnology and materials science, much progress has been made in pharmacy and medicine. Due to the scale reduction, properties that differ substantially from those found on the macro scale are obtained. Titanium dioxide nanoparticles (TiO2 NPs) have found many applications in medicine and industry. In view of this fact, it is necessary to investigate the toxic effects of nanoparticles, either on health or in the environment. It has been well documented that TiO2 NPs can reach the bloodstream and affect various organs, causing inflammatory reactions and cellular interactions that can be pathogenetically relevant. Thus, this work proposes the study of the effects of TiO2 NPs in endothelial cells (HUVEC) cultured in a microfluidic device made of polyester toner (PT), a simple technology that combines speed and low cost of production. The viability of the use of PT microchips was evaluated by MTT assay and production of NO and we found that it is suitable for culturing of endothelial cells. The HUVEC in the microfluidic system were exposed to TiO2 NPs and the results compared to a static system (cell culture plates) subjected to similar conditions. Supernatants from both systems were used for determining the production of the VEGF-A. Furthermore, we have evaluated superoxide anion production and induction of apoptosis. The results clarify the mechanisms of toxicity of NPs TiO2 and are correlated with the pathologies that eventually are associated with these effects. Through this study, we demonstrated the great potential of PT microchips for studies in cell biology, which may provide the basis for pre-clinical trials with greater predictive power, alternative to the use of animals in scientific research.
|
7 |
Desenvolvimento de metodologia de baixo custo para determinação de glifosato usando microdispositivos eletroforéticos fabricados em poliéster-toner / Development of low cost methodology for determination of glyphosate using electrophoretic microdevices fabricated in polyester-tonerEduardo Rodrigues da Silva 15 April 2011 (has links)
Um grande crescimento no interesse por microdispositivos eletroforéticos tem sido observado nos últimos anos. Vantagens atrativas como baixo consumo de reagentes e diminutos tempos de analise são verificados. Microdispositivos fabricados usando toner de impressora e folhas de transparência (poliéster) vem a somar valores como baixo custo e simplicidade de confecção à técnica de micro-separação eletroforética. Entretanto, a aplicação analítica utilizando esse tipo de microdispositivo tem sido pouco explorada. <br />Neste trabalho o uso de microchips eletroforéticos fabricados em poliéster-toner (PT) é utilizado para a determinação simultânea do herbicida glifosato e seu maior metabólito, AMPA (ácido aminometilfosfônico). Em um primeiro momento, o trabalho apresenta o desenvolvimento de uma metodologia no qual utiliza condutometria sem contato (C4D) como sistema de detecção, aliada à separação eletroforética em microchips de PT. Vários parâmetros que regem uma boa confiabilidade analítica, tanto quanto otimizam a sensibilidade do sistema foram avaliados. <br />Em um segundo momento, ainda aliada à microchips de PT, a técnica de cronoamperometria foi utilizada como sistema de detecção. Nessa etapa do projeto estudos eletroquímicos foram inicialmente realizados em eletrodos convencionais de ouro e cobre, buscando averiguar qual metal apresenta maior sensibilidade para o herbicida glifosato. Tendo o metal cobre como melhor escolha, eletrodos planares foram construídos a partir da combinação das tecnologias da produção de máscaras de toner, e placas de circuito impresso como fonte de cobre. <br />Em ambas as metodologias desenvolvidas, picos bem resolvidos foram encontrados para os analitos em estudo. Tempos menores que 80 s foram gastos entre o processo de separação e detecção; uma boa repetibilidade também foi encontrada. Os valores de limite de detecção (LD) utilizando C4D foram 60,8 e 74,8 µmol L-1 para glifosato e AMPA respectivamente. Como esperado, menores valores de LD foram obtidos na detecção amperométrica, com 1,88 µmol L-1 para glifosato e 16,45 µmol L-1 para AMPA. A aplicabilidade dos métodos foi verificada através da analise do herbicida e seu metabólito em amostras de água. Etapas de derivatização e pré-concentração off-line não foram usadas nesse trabalho, dessa forma os dois métodos desenvolvidos apresentaram como principais vantagens o extremo baixo custo, e a simplicidade de uso. / A large increase in interest in electrophoretic microdevices has been observed in recent years. Advantages attractive as low reagent consumption and low analytical time are checked. Microdevices fabricated using printer toner and polyester transparency sheets are the sum values as low cost and simplicity of the technique of making micro-electrophoretic separation. However, the analytical application using this type of microdevice has been little explored. <br />In this work the use of microchip electrophoresis fabricated on polyester-toner (PT) is used for the simultaneous determination of the herbicide glyphosate and its major metabolite, AMPA (aminomethylphosphonic acid). In a first moment, the work presents the development of a methodology in which the use capacitively coupled contactless conductivity detection (C4D) for determination of analytes is employed, coupled with electrophoretic separation in PT microchips. Several parameters that govern a good analytical reliability and with the intuit of optimizing the sensitivity of the system were evaluated. <br />In a second time and still allied to the PT microchips, the technique of chronoamperometry was used for detection. Electrochemical studies were initially conducted in conventional electrodes of gold and copper, looking for determine which metal is more sensitive to detect the herbicide glyphosate. Having the best choice planar copper electrodes were constructed from a combination of technologies for the production of toner masks, and printed circuit boards. <br />In both, C4D and chronoamperometric detection methodologies, well-resolved peaks were found for the glyphosate and AMPA. Time analysis of less than 80s were found including the separation and detection processes, and a good analytical repeatability was also found. The limits of detection (LOD) using C4D were 60,8 and 74,8 µmol L-1 respectively for glyphosate and AMPA. As expected, lower LOD were obtained in the amperometric detection methodology, 1.9 µmol L-1 for glyphosate, and 16.5 µmol L-1 for AMPA. The applicability of the methods was tested by analyzing the herbicide and its metabolite in fortified water samples. Steps of derivatization and preconcentration off-line were not applied in this work, so the two methods showed as main advantages very low cost and time analysis, and simplicity of application.
|
8 |
Extração e amplificação de RNA do vírus da dengue em microchips de poliéster-toner (PeT) / RNA extraction and amplification in polyester-toner (PeT) microchipsGimenez, Thiago Dadalto 24 June 2016 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2016-08-25T18:05:35Z
No. of bitstreams: 2
Dissertação - Thiago Dadalto Gimenez - 2016.pdf: 1825933 bytes, checksum: 5a60bb7603f0e0d32606fdd6c1e83d47 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-08-26T11:38:12Z (GMT) No. of bitstreams: 2
Dissertação - Thiago Dadalto Gimenez - 2016.pdf: 1825933 bytes, checksum: 5a60bb7603f0e0d32606fdd6c1e83d47 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-08-26T11:38:12Z (GMT). No. of bitstreams: 2
Dissertação - Thiago Dadalto Gimenez - 2016.pdf: 1825933 bytes, checksum: 5a60bb7603f0e0d32606fdd6c1e83d47 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2016-06-24 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Miniaturized analytical systems have been successfully used in many analytical and
bioanalytical applications. In the field of clinical diagnoses, microfluidic devices can make
analyses become faster, cheaper and more sensitive, and can also enable the performance of
point-of-care tests. Diagnoses based in molecular biology techniques can be divided in three
main steps (nucleic acid extraction, amplification and detection), and all these steps can be
adapted for microscale. Here, we report the development of RNA analytical methods in
disposable microdevices that may be further used in a micro total analysis system (μTAS).
Analytical methods were developed for dengue virus detection, to enable RNA based molecular
diagnoses in low cost devices. RNA extraction was carried out through a dynamic solid phase
extraction (dSPE) methodology, by using magnetic silica particles. Extraction process occurs
by performing three steps: RNA adsorption to the magnetic silica particles surface, washing of
the beads and elution of purified RNA. PeT microchips used for RNA extraction were produced
by printing, cutting and lamination of polyester films. Microchannels were 18 mm length and
1.2 mm width, and the volume of channels were 6.0 μL. High quality RNA, amplifiable by the
reverse transcription polymerase chain reaction (RT-PCR) and reverse transcription loopmediated
isothermal amplification (RT-LAMP), was obtained by dSPE. In addition to RNA
extraction, the RNA detection by RT-LAMP in PeT devices was also demonstrated in this work.
Amplified products were separated in agarose gel or detected by naked eye visualization after
addition of fluorescent intercalant substances. The success of RNA extraction and amplification
by RT-LAMP demonstrates the potential of PeT microdevices in performing molecular diagnosis
for detection of pathogens whose genome is consisted by RNA. / Os sistemas analíticos miniaturizados vêm sendo utilizados com sucesso em muitas aplicações
analíticas e bioanalíticas. No campo de diagnósticos clínicos, dispositivos microfluídicos podem
tornar as análises mais rápidas, baratas, sensíveis, além de possibilitar a realização de
exames no point-of-care. Diagnósticos baseados em técnicas de biologia molecular podem ser
divididos em três etapas (extração, amplificação e detecção do ácido nucleico), sendo que
todas essas etapas podem ser adaptadas para microescala. Este trabalho apresenta o
desenvolvimento de métodos de análises de RNA em microdispositivos descartáveis que
podem futuramente ser associados em microssistemas para análises totais (μTAS). As
metodologias foram desenvolvidas para detecção do vírus dengue, a fim de possibilitar
diagnósticos moleculares baseados em RNA viral em dispositivos de baixo custo e com as
vantagens associadas à microfluídica. Para a extração do RNA utilizou-se uma metodologia de
extração dinâmica em fase sólida (dSPE), com a utilização de partículas magnéticas de sílica.
O processo de extração ocorre através da realização de três etapas: adsorção do RNA na superfície das partículas magnéticas de sílica, lavagem das partículas e eluição do RNA
purificado. Os microchips de PeT utilizados na extração foram fabricados por impressão, corte
dos canais e laminação dos filmes de poliéster. As dimensões dos canais foram 18 mm de
comprimento e 1,2 mm de largura, sendo que o volume dos canais foi de 6,0 μL. RNA de alta
qualidade, amplificável via reação em cadeia da polimerase pós transcrição reversa (RT-PCR)
e amplificação isotérmica mediada por loop pós transcrição reversa (RT-LAMP), foi obtido
através da dSPE. Além da extração do RNA, a detecção de RNA via RT-LAMP em dispositivos
de PeT também foi demonstrada neste trabalho. Os produtos amplificados foram separados
em gel de agarose ou visualizados a olho nu através da adição de intercaladores
fluorescentes. O sucesso da extração de RNA e da amplificação via RT-LAMP demonstram o
potencial dos microdispositivos de PeT na realização de diagnósticos moleculares para
detecção de patógenos cujo genoma consiste de RNA.
|
9 |
Desenvolvimento de vaso sanguíneo biomimético em plataforma microfluídica de poliéster-toner (PT) / Endothelial cell culture under perfusion on a polyester-toner microfluidic devicePaulo Augusto Gomes Garrido Carneiro Leão 21 October 2016 (has links)
O desenvolvimento de dispositivos microfluídicos biomiméticos, \"órgãos-em-chip\", tem permitido melhores respostas em ensaios que carecem de uma correlação fisiológica mais próxima da in vivo. Explorando as tecnologias da microfluídica e microfabricação, esses dispositivos recapitulam aspectos específicos de estruturas e funções dos órgãos. Ainda, os avanços obtidos em culturas tridimensionais de células, modelos de matrizes extracelulares e tecnologias direcionadas às células tronco, têm consolidado os órgãos-em-chip como uma ferramenta fundamental para a compreensão de diversas respostas biológicas do corpo humano frente às aplicações biomédicas, farmacêuticas, químicas e ambientais. Com os avanços da nanotecnologia e ciência dos materiais, inúmeros progressos têm sido alcançados na farmácia e na medicina. Devido à redução da escala, propriedades que se diferenciam substancialmente daquelas encontradas na escala macro são obtidas. As nanopartículas de dióxido de titânio (NPs TiO2) têm apresentado múltiplas aplicações na medicina e na indústria. Em vista disso, faz-se necessário a investigação dos efeitos tóxicos dessas nanopartículas, seja na saúde ou no meio ambiente. É bem documentado que as NPs TiO2 podem chegar à corrente sanguínea e alcançar vários órgãos, causando reações inflamatórias e interações celulares que podem ser patogenicamente relevantes. Assim, o presente trabalho propõe o estudo dos efeitos das NPs TiO2 em células endoteliais (HUVEC) cultivadas em um dispositivo microfluídico fabricado em poliéster-toner (PT), uma tecnologia simples que alia rapidez e baixo custo de produção. A viabilidade do uso dos microchips de PT foi avaliada por meio do teste MTT e produção de NO e verificou-se serem adequados para a cultura de células endoteliais. As células no sistema microfluídico foram expostas às NPs TiO2, e os resultados comparados a um sistema estático (placas de cultura de células) submetido às condições semelhantes. Os sobrenadantes de ambos os sistemas foram utilizados para determinação da produção de VEGF-A. Ademais, foram avaliadas a produção de aníon superóxido e a indução de apoptose. Os resultados esclarecem os mecanismos de toxicidade das NPs TiO2 e são correlacionados com as patologias que eventualmente estão associadas a esses efeitos. Por meio deste estudo, demonstrou-se o grande potencial dos microchips de PT para estudos em biologia celular, os quais podem fornecer a base para ensaios pré-clinicos com maior poder preditivo, alternativos ao uso de animais e cobaias na pesquisa científica. / The development of biomimetic microfluidic devices, \"organ-on-chips\", has allowed better responses in assays that need a closer in vivo physiological correlation. Exploring the technologies of microfluidics and microfabrication, these devices recapitulate specific aspects of structures and functions of the organs. In addition, the progress made in 3D cell cultures, extracellular matrix models, and stem cells technologies, have consolidated the organ-on-chips as a key tool for understanding various biological responses of the human body in face of biomedical, pharmaceutical, chemical, and environmental applications. With the advances in nanotechnology and materials science, much progress has been made in pharmacy and medicine. Due to the scale reduction, properties that differ substantially from those found on the macro scale are obtained. Titanium dioxide nanoparticles (TiO2 NPs) have found many applications in medicine and industry. In view of this fact, it is necessary to investigate the toxic effects of nanoparticles, either on health or in the environment. It has been well documented that TiO2 NPs can reach the bloodstream and affect various organs, causing inflammatory reactions and cellular interactions that can be pathogenetically relevant. Thus, this work proposes the study of the effects of TiO2 NPs in endothelial cells (HUVEC) cultured in a microfluidic device made of polyester toner (PT), a simple technology that combines speed and low cost of production. The viability of the use of PT microchips was evaluated by MTT assay and production of NO and we found that it is suitable for culturing of endothelial cells. The HUVEC in the microfluidic system were exposed to TiO2 NPs and the results compared to a static system (cell culture plates) subjected to similar conditions. Supernatants from both systems were used for determining the production of the VEGF-A. Furthermore, we have evaluated superoxide anion production and induction of apoptosis. The results clarify the mechanisms of toxicity of NPs TiO2 and are correlated with the pathologies that eventually are associated with these effects. Through this study, we demonstrated the great potential of PT microchips for studies in cell biology, which may provide the basis for pre-clinical trials with greater predictive power, alternative to the use of animals in scientific research.
|
10 |
Untersuchung von Entwicklungs- und Transferprozessen beim flüssigtonerbasierten ferroelektrischen DruckverfahrenReuter, Susann 19 July 2010 (has links) (PDF)
Auch im Zeitalter globaler Verfügbarkeit von Informationen in digitaler Form wird weiterhin gedruckt, denn zahlreiche Druckprodukte sind im Alltag bewährt und nur schwer zu ersetzen. Doch die Anforderungen an die Druckindustrie haben sich in den letzten Jahren deutlich gewandelt: Der Trend geht zu kleineren, differenzierten Auflagen bis hin zum personalisierten Drucken. Daraus erwächst die Forderung nach Technologien, die einen schnellen Wechsel zwischen den einzelnen Aufträgen ermöglichen. In dieser Arbeit wird ein Druckverfahren beschrieben, in dem als Bildträger ferroelektrische Keramikschichten eingesetzt werden. Diese Schichten lassen sich lokal umpolarisieren und ermöglichen so die Realisierung einer informationsgesteuerten Modifikation des elektrischen Oberflächenpotenzials.
Die einzelnen Prozessschritte des Verfahrens werden kurz diskutiert und insbesondere die Teilprozesse der Entwicklung und des Transfers näher untersucht. Zur Beschreibung von elektrisch determinierten Transportvorgängen in elektrostatischen Druckverfahren wird ein einfaches Potenzialstufenmodell vorgeschlagen, das die gezielte Auslegung und Optimierung von einzelnen Systemkomponenten ermöglicht. Der Entwicklungsvorgang an ferroelektrischen Keramikschichten unterliegt dabei grundsätzlich den gleichen physikalischen Zusammenhängen wie die Entwicklung in anderen elektrografischen und elektrofotografischen Verfahren.
Als Druckstoff wurden Flüssigtoner eingesetzt, die wegen ihrer kleinen Partikelgröße eine sehr gute Bildqualität erwarten lassen. Es werden grundsätzliche Modelle zur Ladungsentstehung an Tonerteilchen in nichtwässrigen Dispersionen zusammenfassend vorgestellt und eigene Untersuchungen zur Charakterisierung der elektrophoretischen Beweglichkeit und der Ladung pro Masse diskutiert. Für die Beschreibung der Transferprozesse zur Übertragung des Tonerbildes auf den Bedruckstoff werden Darstellungen aus der konventionellen Drucktechnik mit den für Trockentoner entwickelten Vorstellungen bezüglich der elektrostatischen Verhältnisse verknüpft. Der Einfluss der elektrischen Papiereigenschaften auf die erreichbare optische Dichte wird in eigenen Untersuchungen exemplarisch gezeigt. Unter Berücksichtigung der Forderung nach konstanten Bedingungen für die Entwicklung des Tonerbildes werden Optimierungskriterien für die Auslegung des Transferzylinders abgeleitet, und ein verbesserter Transferzylinder konnte erfolgreich getestet werden.
|
Page generated in 0.054 seconds