• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1581
  • 34
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 1651
  • 1140
  • 731
  • 478
  • 238
  • 237
  • 208
  • 201
  • 198
  • 163
  • 160
  • 151
  • 150
  • 141
  • 140
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Validação da reação da cadeia de polimerase em tempo real para o diagnóstico de neurotoxoplasmose em pacientes com AIDS

da Cunha Correia, Carolina 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T18:29:11Z (GMT). No. of bitstreams: 2 arquivo3566_1.pdf: 7927294 bytes, checksum: add9c73fe4506901113309a0dc549513 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / O diagnóstico da neurotoxoplasmose em portadores de aids pode ser difícil, requerendo distinção com outras neuroinfecções e lesões tumorais. Os exames complementares disponíveis trazem limitações para a confirmação da doença. A tese esteve composta por uma revisão da literatura, abordando o estado de arte dos métodos disponíveis para diagnóstico de neurotoxoplasmose, e por dois artigos: No primeiro, sob título Lesão cerebral única de origem toxoplásmica, foram analisados aspectos de ressonância magnética convencional de 10 pacientes com neurotoxoplasmose e lesão cerebral única, uma vez que essa forma de apresentação impõe maior dificuldade diagnóstica sendo pouco explorada na literatura. As imagens foram avaliadas quanto à localização das lesões, intensidade de sinal, tipo de realce após contraste, presença de alvo excêntrico e captação meníngea, em aparelho Phillips 1,5 Tesla, modelo Achieva®. As lesões não tiveram localização preferencial e ocorreram igualmente em regiões córtico-subcorticais e profundas. Na seqüência T2, houve variabilidade de sinal, porém, no T1, predominaram padrões de iso ou hipossinal, edema perilesional e realce anelar após contraste, aspectos similares aos de lesões múltiplas, descritos na literatura. Concluiu-se que a presença desses padrões em lesões únicas pode ser sugestiva da neurotoxoplasmose. O segundo artigo, sob título Influência de características da neurotoxoplasmose na sensibilidade da PCR em tempo real em pacientes com aids, consistiu de estudo de validação fase III da reação em cadeia da polimerase em tempo real para detecção do gene B1 em sangue e líquor de pacientes com aids e diagnóstico presuntivo de neurotoxoplasmose. O DNA foi extraído com kit QiAmp DNA®, marca Qiagen®; amplificado com uso de primers da marca Applied Biosystem®, com seqüência específica de 98 pares de bases do gene B1. As amostras foram processadas em termociclador Icicle®, marca Biorad®, operado pelo programa PrimerExpress. Foram incluídos 135 pacientes com sintomatologia neurológica encefálica, distribuídos em dois grupos: grupo I - 85 casos de neurotoxoplasmose e grupo II - 50 pacientes com manifestações neurológicas não toxoplásmicas. A PCR em tempo real em sangue revelou sensibilidade de 1,5% (IC 95% 0,1% - 9%), especificidade igual a 100% (IC 95% 87,7% - 100%), valor preditivo positivo de 100% (IC 95% 5,5% - 100%) e valor preditivo negativo de 34,3% (IC 95% 25,4% - 44,4%). No líquor, houve sensibilidade igual a 35,8% (IC 95% 25,7% - 47,3%), especificidade igual a 100,0% (IC 95% 89,6% - 100,0%), valor preditivo positivo de 100.0% (IC 95% 85,4% - 100,0%) e valor preditivo negativo de 44,7% (IC 95% 34,5% - 55,3%). Nos pacientes do grupo I com pleocitorraquia e quatro ou mais lesões encefálicas pelo T gondii, a positividade liquórica da PCR foi significantemente maior do que a daqueles com normocitorraquia (p=0,021) e com até três lesões encefálicas (p=0,026). Concluiu-se que a PCR em tempo real no sangue não se mostrou útil ao diagnóstico; no LCR, o teste demonstrou baixa sensibilidade, mas alta especificidade para o diagnóstico da neurotoxoplasmose. Maior número de lesões e maior celularidade liquórica podem melhorar a sensibilidade do método. Sugerem-se novas pesquisas que correlacionem esses aspectos com os parâmetros de acurácia do método
42

Determinação de endotoxina bacteriana (pirogênio) em radiofármacos pelo método  de formação de gel. Validação / Determination of bacterial endotoxin (pyrogen) in radiopharmaceuticals by the gel clot method. Validation.

Fukumori, Neuza Taeko Okasaki 28 February 2008 (has links)
Antes do Ensaio do Lisado de Amebócitos do Limulus (LAL), a única forma de se avaliar a pirogenicidade em drogas parenterais e dispositivos médicos era o ensaio de pirogênio em coelhos da Farmacopéia Americana (USP). Especialmente para radiofármacos, o ensaio LAL é a escolha para a determinação de endotoxina bacteriana (pirogênio). O objetivo deste trabalho foi validar o método de formação de gel para alguns radiofármacos sem uma interferência mensurável. O guia do método LAL do Food and Drug Administration (FDA) define interferência como uma condição que causa uma diferença significativa entre os pontos finais de gelificação das séries de controle positivo da água e controle positivo do produto utilizando-se um endotoxina padrão. Os experimentos foram realizados de acordo com o teste de endotoxinas bacterianas da USP na m-iodobenzilguanidina-131I, nos radioisótopos Gálio-67 e Tálio-201, nos reagentes liofilizados DTPA, Fitato, GHA, SAH e Sn Coloidal. A Máxima Diluição Válida (MDV) foi calculada para cada produto com base na sua dose clínica e diluições seriadas abaixo da MDV foram avaliadas em duplicata para a detecção de interferências. A sensibilidade declarada do reagente de LAL foi de 0,125 UE mL-1 (Unidades de Endotoxina por mililitro). Para a validação, uma série de diluições foi feita utilizando-se padrão de endotoxina (PE) nas concentrações de 0,5 a 0,03 UE mL-1 para a confirmação da sensibilidade do reagente de LAL, em quadruplicata. A mesma série de diluições foi feita com o PE e o produto diluído 100 vezes em três lotes consecutivos de cada radiofármaco. Os produtos m-iodobenzilguanidina-131I, Gálio-67, Tálio-201, DTPA, SAH e Sn Coloidal foram compatíveis com o método no fator de diluição 1:100. Fitato e GHA apresentaram interferência no ensaio de formação de gel. Outras técnicas para determinar endotoxinas como o ensaio cromogênico (desenvolvimento de cor) e o turbidimétrico (desenvolvimento de turbidez) foram avaliadas para obter informações qualitativas e quantitativas sobre as concentrações de endotoxinas nas amostras. / Before the Limulus amebocyte lysate (LAL) test, the only available means of pirogenicity testing for parenteral drugs and medical devices was the United States Pharmacopoeia (USP) rabbit pyrogen test. Especially for radiopharmaceuticals, the LAL assay is the elective way to determine bacterial endotoxin. The aim of this work was to validate the gel clot method for some radiopharmaceuticals without measurable interference. The FDAs LALTest guideline defines interference as a condition that causes a significant difference between the endpoints of a positive water control and positive product control series using a standard endotoxin. Experiments were performed in accordance to the USP bacterial endotoxins test in the 131I- m-iodobenzylguanidine; the radioisotopes Gallium-67 and Thallium-201; the liophylized reagents DTPA, Phytate, GHA, HSA and Colloidal Tin. The Maximum Valid Dilution (MVD) was calculated for each product based upon the clinical dose of the material and a twofold serial dilution below the MVD was performed in duplicate to detect interferences. The labeled sensitivity of the used LAL reagent was 0.125 EU mL-1 (Endotoxin Units per milliliter). For validation, a dilution series was performed, a twofold dilution of control standard endotoxin (CSE) from 0.5 to 0.03 EU mL-1, to confirm the labeled sensitivity of the LAL reagent being tested in sterile and non pyrogenic water, in quadruplicate. The same dilution series was performed with the CSE and the product in the 1:100 dilution factor, in three consecutive batches of each radiopharmaceutical. The products 131I-m-iodobenzylguanidine, Gallium-67, Thallium-201, DTPA, HSA and Colloidal Tin were found compatible with the LAL test at a 1:100 dilution factor. Phytate and GHA showed some interference in the gel clot test. Other techniques to determine endotoxins as the chromogenic (color development) and the turbidimetric test (turbidity development), were also assessed to get valuable quantitative and qualitative information about the endotoxin concentration in samples.
43

Bioacumulação do herbicida atrazina pelas espécies de bivalves limnicos Anodontites trapesialis (Lamarck, 1819) e Corbicula fluminea (Müller, 1774) / Bio accumulation of the atrazina herbicida for trapesialis the limnicos species of bivalves Anodontites (Lamarck, 1819) and fluminea Corbicula (Müller, 1774).

Jacomini, Analú Egydio 30 April 2002 (has links)
Inúmeros pesticidas são usados na agricultura, para controle de pragas e ervas daninhas. Dentre eles destaca-se o herbicida atrazina, intensivamente utilizado nas culturas de cana-de-açúcar, milho e sorgo, que ocupam extensas áreas no estado de São Paulo. Grande parcela do herbicida, que é aplicado na agricultura, entra em contato com o solo, podendo ser lixiviado, atingindo as águas superficiais. Neste sentido, alguns animais como, por exemplo, moluscos bivalves, podem ser utilizados como monitores biológicos do ambiente aquático e auxiliar no estudo da ecotoxicologia. Considerando o risco de contaminação do ambiente aquático pela atrazina, propõe-se, no presente trabalho, desenvolver uma metodologia de análise daquele herbicida nos tecidos nas espécies de bivalves límnicos Anodontites trapesialis (LAMARCK, 1819) e Corbicula fluminea (Muller, 1789), validar esse método e, finalmente, verificar se ocorre a bioacumulação do herbicida nas partes moles dessas duas espécies. Como técnica de extração utilizou-se a extração líquido- líquido e como técnica de análise, a cromatografia líquida de alta eficiência (CLAE). / Large amount of pesticides have been used for the control of agriculture pests and weeds. Particularly important among herbicides is atrazine, extensively employed in cultures of sugar cane, corn and sorghum, that occupies an extensive area in São Paulo state. Large portions of atrazine, applied in the agricultural fields, leaches from the soil to surface water systems. In this way, some organisms such as fresh- water mollusks bivalves, can be used as biological monitors of aquatic environments, contributing for ecotoxicology studies. Considering the existence of risk of contamination by atrazine of the aquatic environment, the purpose of this work was, (i) to develop a method for the analysis of atrazine in the fresh- water bivalves species Anodontites trapesialis (LAMARCK, 1819) and Corbicula fluminea (MULLER, 1789), (ii) to validate such method and, (iii) to detect if these organisms can bioaccumulate atrazine in their tissues. This method involved a simple liquid-liquid extraction procedure, followed by high- performance liquid chromatographic analysis (HPLC).
44

Aplicação de ferramentas da qualidade no desenvolvimento de métodos multiresíduos / Application of quality tools in the multiresidue methods development

Costa, Sergio Pereira da 14 December 2012 (has links)
O presente trabalho estuda a aplicação de ferramentas da qualidade em dois métodos multiresíduos, sendo utilizados como instrumento para desenvolvimento de novos métodos e otimização de métodos existentes. As ferramentas utilizadas foram o planejamento experimental, a validação de métodos e o cálculo de incerteza de medição, as quais foram aplicadas no método QuEChERS, já bem difundido na literatura, e no método RSE (Refrigerated Sorptive Extraction), técnica miniaturizada de extração. Foi aplicado planejamento experimental no método QuEChERS visando a otimização do processo de extração de organoclorados (14 no total, sendo 12 Organoclorados e 2 PCBs) em pescado, em que obteve-se valores de recuperação satisfatórios dentro da faixa de 70 a 120 % como é exigido pelo protocolo de validação SANCO 12495:2011. Neste processo foi otimizado as quantidades de sais de trabalho como NaCl, C18 e o PSA, fatores que interferem diretamente no resultado final de recuperação. A mesma ferramenta de planejamento experimental foi utilizada na otimização da fase de PDMS (fase extratora do sistema RSE desenvolvido) visando obter a melhor condição de trabalho, atuando com os fatores de temperatura e tempo de mufla, além do tempo de exposição ao meio ambiente para resfriamento entre a pré-cura e a pós-cura. O processo de validação e cálculo de incerteza de medição foi realizado para o método QuEChERS avaliando parâmetros primordiais para demonstrar que o método é adequado ao uso pretendido. Foi estudado o parâmetro linearidade, pelo coeficiente de determinação, resíduos e incerteza da curva, além da aplicação de metodologia de investigação na adequação da curva analítica linear, com testes como outlier, homoscedasticidade e modelo. Os dados apresentados foram satisfatórios, observando resultados dentro do que foi planejado, inexistência de outliers pela utilização do teste de Grubbs (foi encontrado valores perto do limite máximo do valor critico para os compostos ppE e ppD), teste de Cochran para análise de homoscedasticidade nos resíduos em torno da curva (todos se apresentaram homogêneos com o teste utilizado) e o teste de modelo com o teste de falta de ajuste, em que foi averiguado se o modelo linear é o mais adequado para metodologia. Além da linearidade, também foram avaliados os parâmetros seletividade, precisão (com CV abaixo dos 20%) e recuperação (valores entre 70 e 120%), fatores primordiais para o processo de validação, considerando que alguns destes também influenciam diretamente na incerteza do resultado final. Desta maneira foi possível avaliar a aplicabilidade do planejamento experimental no desenvolvimento de novos métodos de extração, como no caso do RSE, bem como na otimização de métodos já bem fundamentados, como no caso do método QuEChERS, se demonstrando como ferramenta primordial em ambos os casos. Quanto ao método QuEChERS, também foi possível avaliar a adequação do método quanto aos requisitos de validação e incerteza, os quais são essenciais para confiabilidade dos resultados analíticos. / The paper studies the application of quality tools in two multiresidue methods, being used as a tool for developing and optimization methods. The tools used were the experimental design, method validation and measurement uncertainty, which were applied in the QuEChERS method, already widespread in the literature, and the RSE method (Refrigerated Sorptive Extraction), miniaturized extraction technique. Experimental design was applied in the QuEChERS method in order to optimize the extraction process of organochlorines (14 in total, 12 Organochlorines and 2 PCBs) in fish, which gave satisfactory recovery values within the range of 70 to 120% as is required by the validation protocol SANCO 12495:2011. This process was optimized the quantities of salts as NaCl, C18 and PSA, factors that directly affect the final outcome of recovery. The same experimental design tool was used in the optimization of extraction phase (PDMS extraction phase system developed to RSE) to obtain the best working condition, leading with the factors as time and temperature on the muffle, and the time of exposure to the environment to cooling between pre-cure and post-cure. The process of validation and measurement uncertainty was conducted to evaluate the method QuEChERS parameters to show that the method is suitable for the purpose. We studied the linearity parameter, the determination coefficient, residues and uncertainty of the linear curve, and the application of a methodology to observe the adequacy of the linear calibration curve, with testing as an outlier and homoscedasticity model. The data presented were satisfactory, no outliers was identified by the Grubbs test (values was found near the upper limit of the critical value for compounds PPE and PPD), Cochran test for analysis of homoscedasticity in the residue around the calibration curve (all performed with homogeneous assay) and the test model with the lack of fit test, where it was examined whether the linear model is the most appropriate for methodology. Besides linearity, were also evaluated parameters as selectivity, precision (CV below 20%) and recovery (values between 70 and 120%), important factors for the validation process, whereas some of these also has influenced of the final results of uncertainty. In this way it was possible to evaluate the applicability of the experimental design to develop new extraction methods, as in the case of RSE, and the optimization of the method QuEChERS demonstrating an important tool in both cases. For the QuEChERS method was also possible to assess the adequacy of the method for the requirements validation and uncertainty, which are essential for reliability of analytical results.
45

Uma ferramenta de apoio ao teste de regressão

Granja, Ivan 17 December 1997 (has links)
Orientador: Mario Jino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-23T05:23:57Z (GMT). No. of bitstreams: 1 Granja_Ivan_M.pdf: 9510547 bytes, checksum: 4248dfe94031c5719e837aa99627acca (MD5) Previous issue date: 1997 / Resumo: Este trabalho apresenta as principais características de uma ferramenta de apoio ao teste de regressão estrutural baseado na família de Critérios Potenciais-Usos e uma estratégia para sua aplicação. A ferramenta, denominada RePoKe- Tool (Regression Testing support for Potencial-Uses Criteria Tool), pode ser aplicada em unidades (e.g., funções, procedimentos) que foram testadas através da ferramenta de teste POKE-TOOL e sofreram manutenção corretiva (teste de regressão corretivo) ou então adaptativa ou perfectiva (teste de regressão progressivo), utiliza estratégia seletiva para identificar apenas os elementos requeridos para o teste estrutural (caminhos e associações) que foram inseridos ou modificados após essa manutenção e sugere um subconjunto dos casos de teste originais que, potencialmente, cobre esses elementos. Além disso, configura e atualiza os arquivos necessários para que a POKE-TOOL possa realizar o teste de regressão. o trabalho apresenta também estudos de casos que mostram a viabilidade da aplicação de uma estratégia de seleção de casos de testes de regressão baseada em conceitos de teste funcional, com objetivo de atingir um bom índice de cobertura de elementos requeridos selecionados para o teste de regressão estrutural. Os resultados obtidos através desses estudos de casos contribuíram para a definição de um Guia de Referência para Programadores de Manutenção, cujo objetivo é diminuir os altos custos envolvidos com o Teste de Regressão, sem relevar para segundo plano o principal objetivo de qualquer atividade de teste: a revelação de defeitos no software / Abstract: This work presents the most relevant concepts and characteristics of a regression testing tool, based upon Potential Uses Criteria and a strategy to be applied. RePoKe- Tool (Regression Testing support for Potential-Uses Criteria Tool) can be used in units (e.g., functions and procedures). These units, previously tested by POKE-TOOL testing tool, have been modified either by means of a corrective maintenance (which implies in corrective regression testing) or by means of an adaptive or perfective maintenance (which implies in progressive regression testing). This regression testing toei uses a selective strategy to identify modified and new required elements for white-box testing (paths and associations) and select a subset of original test cases (used in original testing procedures) which potentialiy may cover these elements. Furthermore, the POKE-TOOL environment is reconfigured to avoid regression testing procedures. This work presents, additionaliy, a study of cases that show a selection strategy based upon black-box testing concepts that obtain an expressive cover of white-box required elements. The results help the definition of a guideline to support maintenance programming activities, whose objectives are to save cost and, above all, to reveal faults in modified software / Mestrado / Mestre em Engenharia Elétrica
46

Aplicação de ferramentas da qualidade no desenvolvimento de métodos multiresíduos / Application of quality tools in the multiresidue methods development

Sergio Pereira da Costa 14 December 2012 (has links)
O presente trabalho estuda a aplicação de ferramentas da qualidade em dois métodos multiresíduos, sendo utilizados como instrumento para desenvolvimento de novos métodos e otimização de métodos existentes. As ferramentas utilizadas foram o planejamento experimental, a validação de métodos e o cálculo de incerteza de medição, as quais foram aplicadas no método QuEChERS, já bem difundido na literatura, e no método RSE (Refrigerated Sorptive Extraction), técnica miniaturizada de extração. Foi aplicado planejamento experimental no método QuEChERS visando a otimização do processo de extração de organoclorados (14 no total, sendo 12 Organoclorados e 2 PCBs) em pescado, em que obteve-se valores de recuperação satisfatórios dentro da faixa de 70 a 120 % como é exigido pelo protocolo de validação SANCO 12495:2011. Neste processo foi otimizado as quantidades de sais de trabalho como NaCl, C18 e o PSA, fatores que interferem diretamente no resultado final de recuperação. A mesma ferramenta de planejamento experimental foi utilizada na otimização da fase de PDMS (fase extratora do sistema RSE desenvolvido) visando obter a melhor condição de trabalho, atuando com os fatores de temperatura e tempo de mufla, além do tempo de exposição ao meio ambiente para resfriamento entre a pré-cura e a pós-cura. O processo de validação e cálculo de incerteza de medição foi realizado para o método QuEChERS avaliando parâmetros primordiais para demonstrar que o método é adequado ao uso pretendido. Foi estudado o parâmetro linearidade, pelo coeficiente de determinação, resíduos e incerteza da curva, além da aplicação de metodologia de investigação na adequação da curva analítica linear, com testes como outlier, homoscedasticidade e modelo. Os dados apresentados foram satisfatórios, observando resultados dentro do que foi planejado, inexistência de outliers pela utilização do teste de Grubbs (foi encontrado valores perto do limite máximo do valor critico para os compostos ppE e ppD), teste de Cochran para análise de homoscedasticidade nos resíduos em torno da curva (todos se apresentaram homogêneos com o teste utilizado) e o teste de modelo com o teste de falta de ajuste, em que foi averiguado se o modelo linear é o mais adequado para metodologia. Além da linearidade, também foram avaliados os parâmetros seletividade, precisão (com CV abaixo dos 20%) e recuperação (valores entre 70 e 120%), fatores primordiais para o processo de validação, considerando que alguns destes também influenciam diretamente na incerteza do resultado final. Desta maneira foi possível avaliar a aplicabilidade do planejamento experimental no desenvolvimento de novos métodos de extração, como no caso do RSE, bem como na otimização de métodos já bem fundamentados, como no caso do método QuEChERS, se demonstrando como ferramenta primordial em ambos os casos. Quanto ao método QuEChERS, também foi possível avaliar a adequação do método quanto aos requisitos de validação e incerteza, os quais são essenciais para confiabilidade dos resultados analíticos. / The paper studies the application of quality tools in two multiresidue methods, being used as a tool for developing and optimization methods. The tools used were the experimental design, method validation and measurement uncertainty, which were applied in the QuEChERS method, already widespread in the literature, and the RSE method (Refrigerated Sorptive Extraction), miniaturized extraction technique. Experimental design was applied in the QuEChERS method in order to optimize the extraction process of organochlorines (14 in total, 12 Organochlorines and 2 PCBs) in fish, which gave satisfactory recovery values within the range of 70 to 120% as is required by the validation protocol SANCO 12495:2011. This process was optimized the quantities of salts as NaCl, C18 and PSA, factors that directly affect the final outcome of recovery. The same experimental design tool was used in the optimization of extraction phase (PDMS extraction phase system developed to RSE) to obtain the best working condition, leading with the factors as time and temperature on the muffle, and the time of exposure to the environment to cooling between pre-cure and post-cure. The process of validation and measurement uncertainty was conducted to evaluate the method QuEChERS parameters to show that the method is suitable for the purpose. We studied the linearity parameter, the determination coefficient, residues and uncertainty of the linear curve, and the application of a methodology to observe the adequacy of the linear calibration curve, with testing as an outlier and homoscedasticity model. The data presented were satisfactory, no outliers was identified by the Grubbs test (values was found near the upper limit of the critical value for compounds PPE and PPD), Cochran test for analysis of homoscedasticity in the residue around the calibration curve (all performed with homogeneous assay) and the test model with the lack of fit test, where it was examined whether the linear model is the most appropriate for methodology. Besides linearity, were also evaluated parameters as selectivity, precision (CV below 20%) and recovery (values between 70 and 120%), important factors for the validation process, whereas some of these also has influenced of the final results of uncertainty. In this way it was possible to evaluate the applicability of the experimental design to develop new extraction methods, as in the case of RSE, and the optimization of the method QuEChERS demonstrating an important tool in both cases. For the QuEChERS method was also possible to assess the adequacy of the method for the requirements validation and uncertainty, which are essential for reliability of analytical results.
47

Determinação de endotoxina bacteriana (pirogênio) em radiofármacos pelo método  de formação de gel. Validação / Determination of bacterial endotoxin (pyrogen) in radiopharmaceuticals by the gel clot method. Validation.

Neuza Taeko Okasaki Fukumori 28 February 2008 (has links)
Antes do Ensaio do Lisado de Amebócitos do Limulus (LAL), a única forma de se avaliar a pirogenicidade em drogas parenterais e dispositivos médicos era o ensaio de pirogênio em coelhos da Farmacopéia Americana (USP). Especialmente para radiofármacos, o ensaio LAL é a escolha para a determinação de endotoxina bacteriana (pirogênio). O objetivo deste trabalho foi validar o método de formação de gel para alguns radiofármacos sem uma interferência mensurável. O guia do método LAL do Food and Drug Administration (FDA) define interferência como uma condição que causa uma diferença significativa entre os pontos finais de gelificação das séries de controle positivo da água e controle positivo do produto utilizando-se um endotoxina padrão. Os experimentos foram realizados de acordo com o teste de endotoxinas bacterianas da USP na m-iodobenzilguanidina-131I, nos radioisótopos Gálio-67 e Tálio-201, nos reagentes liofilizados DTPA, Fitato, GHA, SAH e Sn Coloidal. A Máxima Diluição Válida (MDV) foi calculada para cada produto com base na sua dose clínica e diluições seriadas abaixo da MDV foram avaliadas em duplicata para a detecção de interferências. A sensibilidade declarada do reagente de LAL foi de 0,125 UE mL-1 (Unidades de Endotoxina por mililitro). Para a validação, uma série de diluições foi feita utilizando-se padrão de endotoxina (PE) nas concentrações de 0,5 a 0,03 UE mL-1 para a confirmação da sensibilidade do reagente de LAL, em quadruplicata. A mesma série de diluições foi feita com o PE e o produto diluído 100 vezes em três lotes consecutivos de cada radiofármaco. Os produtos m-iodobenzilguanidina-131I, Gálio-67, Tálio-201, DTPA, SAH e Sn Coloidal foram compatíveis com o método no fator de diluição 1:100. Fitato e GHA apresentaram interferência no ensaio de formação de gel. Outras técnicas para determinar endotoxinas como o ensaio cromogênico (desenvolvimento de cor) e o turbidimétrico (desenvolvimento de turbidez) foram avaliadas para obter informações qualitativas e quantitativas sobre as concentrações de endotoxinas nas amostras. / Before the Limulus amebocyte lysate (LAL) test, the only available means of pirogenicity testing for parenteral drugs and medical devices was the United States Pharmacopoeia (USP) rabbit pyrogen test. Especially for radiopharmaceuticals, the LAL assay is the elective way to determine bacterial endotoxin. The aim of this work was to validate the gel clot method for some radiopharmaceuticals without measurable interference. The FDAs LALTest guideline defines interference as a condition that causes a significant difference between the endpoints of a positive water control and positive product control series using a standard endotoxin. Experiments were performed in accordance to the USP bacterial endotoxins test in the 131I- m-iodobenzylguanidine; the radioisotopes Gallium-67 and Thallium-201; the liophylized reagents DTPA, Phytate, GHA, HSA and Colloidal Tin. The Maximum Valid Dilution (MVD) was calculated for each product based upon the clinical dose of the material and a twofold serial dilution below the MVD was performed in duplicate to detect interferences. The labeled sensitivity of the used LAL reagent was 0.125 EU mL-1 (Endotoxin Units per milliliter). For validation, a dilution series was performed, a twofold dilution of control standard endotoxin (CSE) from 0.5 to 0.03 EU mL-1, to confirm the labeled sensitivity of the LAL reagent being tested in sterile and non pyrogenic water, in quadruplicate. The same dilution series was performed with the CSE and the product in the 1:100 dilution factor, in three consecutive batches of each radiopharmaceutical. The products 131I-m-iodobenzylguanidine, Gallium-67, Thallium-201, DTPA, HSA and Colloidal Tin were found compatible with the LAL test at a 1:100 dilution factor. Phytate and GHA showed some interference in the gel clot test. Other techniques to determine endotoxins as the chromogenic (color development) and the turbidimetric test (turbidity development), were also assessed to get valuable quantitative and qualitative information about the endotoxin concentration in samples.
48

Avaliação da relação médico-paciente : tradução e validação do Patient-Doctor Relationship Questionnaire (PDRQ-9) no Brasil

Wollmann, Lucas January 2017 (has links)
Resumo não disponível
49

Centro de Novas Oportunidades Martifer Inovação e Gestão : capacitação da organização e das pessoas

Folha, Susana Alexandra da Silva January 2010 (has links)
O presente estudo aborda a temática da Educação e Formação de Adultos, nomeadamente as políticas existentes, na actualidade, em Portugal relacionando-as com o universo organizacional e com uma dimensão individual. Esta relação é estudada através do Centro Novas Oportunidades (CNO) da empresa Martifer Inovação e Gestão, designadamente, através dos adultos certificados pelo CNO a partir do processo de Reconhecimento Validação e Certificação de Competências (RVCC) e divide-se em duas vertentes: 1. Avaliação dos seus efeitos nas dimensões formativa e, também, social e comunitária; individual, laboral, educativa e 2. CNO enquanto estratégia, ou não,de capacitação da organização. Neste trabalho, responde-se a duas grandes questões que são o fio condutor de todo o estudo: 1. Qual a importância e o papel do Centro de Novas Oportunidades na estratégia da empresa? 2. Qual o impacto da obtenção de certificação, através da frequência do Centro Novas Oportunidades Martifer Inovação e Gestão, no adulto certificado? Sente-se mais satisfeito e valorizado profissional e pessoalmente? Têm expectativas em termos de desenvolvimento e progressão profissional no âmbito da empresa? Uma vez que vivemos numa sociedade da infonnação, na qual o conhecimento é a "moeda de troca", toma-se pertinente reflectir e analisar a forma como as empresas agem no ambito da educação e fonnação de adultos, assim como, sobre as consequências que tem na vida social e profissional do adulto e para a própria organização.
50

Tradução, adaptação transcultural e validação de um questionário de conhecimento sobre hipertensão arterial sistêmica

Arthur, Juliana Perez January 2017 (has links)
Orientadora: Profª Drª Maria de Fátima Mantovani / Coorientadora: Profª Drª Maria Isabel Raimondo Ferraz / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação Mestrado Profissional em Enfermagem. Defesa: Curitiba, 20/10/2017 / Inclui referências : p. 93-102 / Resumo: Introdução: o conhecimento sobre a doença é um importante fator no seguimento terapêutico e este deve ser avaliado pelos profissionais de saúde para a condução do cuidado. Visando mensurar o conhecimento de adultos sobre hipertensão arterial, pesquisadores turcos elaboraram e validaram em 2012 a Hypertension Knowledge-Level Scale, um questionário composto por 22 afirmativas e dividido em seis subdimensões publicado no idioma inglês. Objetivo: traduzir, adaptar transculturalmente e validar para o português do Brasil a Hypertension Knowledge-Level Scale. Metodologia: trata-se de uma pesquisa metodológica cujo processo de tradução e adaptação transcultural foi composto por seis etapas: tradução, síntese das traduções, retrotradução, comitê de especialistas, pré-teste e apresentação da documentação para os desenvolvedores. A validação de conteúdo do instrumento foi realizada com o auxílio de experts e utilizou-se a técnica Delphi online. A pesquisa foi desenvolvida no período de março de 2016 a outubro de 2017 nas dependências da Universidade Federal do Paraná e em uma unidade de saúde do município de Curitiba. A análise de dados ocorreu por meio de estatística descritiva e inferencial, sendo utilizado o teste t unilateral para comparação entre grupos no pré-teste, o índice de validade de conteúdo para concordância entre experts e o Alfa de Cronbach para avaliação da confiabilidade. Resultados: nas etapas de tradução e adaptação transcultural foram realizadas alterações de modo a adequar o instrumento à cultura brasileira e optou-se pela alteração do tempo verbal passado para o presente. O pré-teste foi realizado com 40 adultos e evidenciou as principais dificuldades dos respondentes com relação ao questionário, permitindo uma visão crítica do instrumento. Na validação de conteúdo 35 experts participaram da primeira rodada, 28 da segunda e cinco na reunião de consenso. O índice de validade de conteúdo foi de 0,96 e a confiabilidade foi de 0,92. Conclusão: a escala foi traduzida, adaptada transculturalmente para o português do Brasil, teve seu conteúdo validado e demonstrou-se confiável para avaliar o conhecimento sobre a hipertensão arterial entre adultos brasileiros. Palavras-chave: Conhecimento. Hipertensão. Inquéritos e Questionários. Estudos de validação. Enfermagem. / Abstract: Introduction: the knowledge about the disease is an important factor in the therapeutic follow-up. It should be used by health professionals for the planning of care. In order to measure adult knowledge about hypertension, Turkish researchers developed and validated, in 2012, the Hypertension Knowledge-Level Scale, a questionnaire with 22 statements, divided into six sub-dimensions, published in the English language. Objective: Hypertension Knowledge-Level Scale translation, cross-cultural adaptation and validation into Brazilian Portuguese. Methodology: methodological research whose translation and cross-cultural adaptation process was composed of six stages: translation, synthesis of translations, back-translation, experts committee, pre-test and presentation of documentation for developers. The instrument content validation was performed with by experts and the online Delphi technique was used. This research was carried out from March 2016 to October 2017 at the Federal University of Parana and a primary health care unit at Curitiba. The data analysis was performed using descriptive and inferential statistics, used the unilateral t-test for comparison between groups in the pre-test, the content validity index, for agreement between experts, and the Cronbach's Alpha for reliability assessment. Results: in the stages of translation and cross-cultural adaptation, the changes were made to adapt the instrument to the Brazilian culture and the past tense was changed to the present tense. The pre-test was performed with 40 adults and showed the main difficulties of the respondents with the questionnaire, allowing a critical view of the instrument. In the content validation, 35 experts participated at the first round, 28 in the second round and five in the consensus meeting. The content validity index was 0.96 and the reliability assessment was 0.92. Conclusion: the scale was translated, adapted transculturally into Brazilian Portuguese, was validated and proved reliable to evaluate the knowledge about hypertension among Brazilian adults. Keywords: Knowledge. Hypertension. Surveys and Questionnaires. Validation studies. Nursing. / Riassunto: Introduzione: la conoscenza della malattia è un fattore importante nel follow-up terapeutico e questo deve essere valutato dagli professionist della salute per la cura. Per misurare la conoscenza degli adulti sull'ipertensione, ricercatori turchi hanno preparato e convalidato, nel 2012, la Hypertension Knowledge-Level Scale, un questionario composto da 22 dichiarazioni e suddiviso in sei sotto-dimensioni pubblicato in lingua inglese. Obiettivo: tradurre, adattare transculturalmente e validare per il portoghese brasiliano la Hypertension Knowledge-Level Scale Metodologia: ricerca metodologica in il processo di traduzione e adattamento transculturale sono stati composti da sei fasi: traduzione, sintesi delle traduzioni, back-translation, comitato di esperti, pre-test e presentazione della documentazione per gli sviluppatori. La validazione del contenuto degli strumenti è stata eseguita con l'aiuto di esperti e la tecnica Delphi online è stata utilizzata. La ricerca è stata effettuata dal marzo 2016 all'ottobre 2017 presso l'Università Federale del Paraná e presso un'unità di cure primarie nella città di Curitiba. L'analisi dei dati è stata eseguita utilizzando statistiche descrittive e inferenziali, utilizzando il t-test unilaterale per il confronto tra i gruppi nel pre-test, l'indice di validità dei contenuti per l'accordo tra gli esperti e l'Alpha di Cronbach per la valutazione dell'affidabilità. Risultati: nelle fasi della traduzione e dell'adattamento transculturale, sono state apportate modifiche per adattare lo strumento alla cultura brasiliana e si è deciso di cambiare il tempo verbale dal passato al presente. Il pre-test è stato eseguito con 40 adulti e ha mostrato le principali difficoltà degli intervistati rispetto al questionario, permettendo una visione critica dello strumento. Nella validazione dei contenuti 35 esperti hanno partecipato al primo turno, 28 al secondo turno e cinque alla riunione di consenso. L'indice di validità del contenuto è stato di 0,96 e l'affidabilità è stata di 0,92. Conclusioni: la scala è stata tradotta, adattata in modo transculturale per il portoghese brasiliano, il suo contenuto è stato validato e dimostrato affidabile per valutare le conoscenze sull'ipertensione arteriosa tra gli adulti brasiliani. Parole chiave: Conoscenza. Ipertensione. Sondaggi e questionari. Studi di validazione. Infermieristica.

Page generated in 0.0356 seconds