• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 44
  • 33
  • 16
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 118
  • 38
  • 24
  • 21
  • 13
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Energieffektivisering av äldre byggnader : Konstruktion & ventilation i Växjö kommunhus

Salcin, Elmir January 2012 (has links)
Inom EU vill man sänka energianvändningen med 20 % till 2020. Växjö kommunhus har gamla och ineffektiva installationer, samt ett dåligt isolerat och otät klimatskal. Denna rapport undersöker vad för slags inverkan byte av installationer, samt byte av klimatskal, har för inverkan på kommunhusets energianvändning. Till detta har energiberäkningsprogrammet VIP-Energy 1.5.5 använts. För att sammanfatta resultatet av arbetet så är det mest effektiva och lönsamma alternativet att byta ut installationerna, samt att kylbehovet ökar då man kraftigt isolerar detta hus.
62

The Value of Social Capital : A cross-sectional study of Swedish high school student's social capital and its association with lifestyle factors, psychological well-being and academic achievement.

Murphy, Jason January 2011 (has links)
Background: Many of today’s young adults suffer from impaired psychological well-being and report suffering from psycho-somatic symptoms related to stress. Lifestyle factors, such as smoking, risky alcohol consumption, lack of physical activity and poor diet are known predictors of ill health and may have long lasting impacts on young people’s lives. Aim: The aim of this thesis was to 1: measure adult high school students’ social capital and 2: examine the association between their social capital and psychological well-being as well as the association between social capital and the lifestyle factors; smoking, alcohol consumption, physical activity, diet and academic achievement. Methods: Questionnaires were used to measure high school students’ social capital self- rated psychological health, lifestyle factors and academic achievement. Participants were high school students 18 years and older (n=124) enrolled in Nacka Enskilda Gymnasium and Mörby Gymnasium, two high schools in counties with similar demographic backgrounds, measured in annual salaries, on the outskirts of Stockholm, Sweden. Results: Total social capital was significantly associated with no less than 6 factors of health; self-rated mental health, self-rated stress, psycho-somatic symptoms, intensive physical exercise, consumption of fruit and membership to a club. In addition, consumption of vegetables and expected grade point average (Grade point average (GPA): final GPA’s in Sweden range from 0-20) were significantly associated with individual factors of social capital. Conclusion: The results of this study support the findings of many earlier studies; that social capital appears to be significantly associated with young peoples’ health and well-being. The findings lend weight to earlier studies and contribute to the multitude of voices that lobby for investing in the further development of policies and interventions that aim to increase young peoples’ social capital.
63

The study of brand image in wealth management bank

Huang, Wen-ching 31 August 2004 (has links)
Abstract Under long-term incandescent competition, the difference of product features of banking business is more and more smaller. Only which could supply service can emerge. To establish difference of wealth management service, the high quality enterprise image to attract consumers is needed besides supplying valuable finance planning and professional financing commissioner¡¦s customer relationship administration. Establishing brand image and good communication with consumers are the principal tools of building wealth management bank. This study reviewed related documents to understand the wealth management service actualities of VIP financing center. The questionnaire in the point view of consumer was used to investigate good brand image of wealth administration for public. In order to set a construct model of brand image and supply marketing policy for banks, demonstration analysis method was also adopted. The results of this study are followed: 1. The bank wanting to create higher brand image should start from brand identification and brand orientation. This result agrees with the brand image definition made by Aaker, Kapferer, Keller and Biel. The brand image means consumers¡¦ cognition of brand attribute, in another words, it was represented due to development of brand orientation, result of communicating action and consumers¡¦ memory associating with brand in thinking. It was believed that, to construct the brand image of wealth management bank should start from brand orientation to brand identification. And careful planning could construct brand image effectively. 2. The bank desiring to construct their brand image from brand orientation effectively should strengthen their wealth administration to satisfy customer¡¦s empirical requirement. For example, preparing perfect service illustration data, sharing initiative timely information, supporting integrated-bill monthly and global market analysis report, evaluating investment performance regularly, establishing faith and interaction between consultant and consumer, and paying much attention to consumers¡¦ requirement such as attitude and timing of treating customer¡¦s opinion.
64

Pacap and vip modulation of neuroexcitability in rat intracardiac neurons

DeHaven, Wayne I 01 June 2005 (has links)
Autonomic control of cardiac function depends on the coordinated activity generated by neurons within the intracardiac ganglia, and intrinsic feedback loops within the ganglia provide precise control of cardiac function. Both pituitary adenylate cyclase-activating polypeptide (PACAP) and vasoactive intestinal polypeptide (VIP) are important regulators of cell-to-cell signaling within the intracardiac ganglia, and PACAP and VIP action on these ganglia, mediated through associated receptors, play an important role in the regulation of coronary blood flow, cardiac contraction, relaxation, and heart rate. Results reported here using PACAP and VIP provide direct evidence of some of the complex signaling which occurs in neurons of the rat intracardiac ganglia.
65

Modélisation du comportement thermique à long terme des panneaux isolants sous vide : (PIV) / Modelling of long-term thermal behaviour of vacuum insulation panels : (VIP)

Batard, Antoine 14 February 2017 (has links)
On peut distinguer deux familles d'isolants thermiques pour le bâtiment : les isolants dits traditionnels et les super-isolants qui se caractérisent par un pouvoir isolant plus performant qu'une simple lame d'air immobile (25 mW/m/K). Les Panneaux Isolants sous Vide (PIV) font partie de cette seconde catégorie. Un PIV n'est pas un matériau homogène, mais un système constitué d'un matériau de cœur mis sous vide et enfermé dans une enveloppe. La performance thermique du PIV repose sur la structure nano-poreuse du matériau de cœur et du vide primaire maintenu par l'enveloppe qui possède une très faible perméabilité aux gaz. Alors que les isolants traditionnels ont des conductivités thermiques allant de 21 mW/m/K pour la mousse polyuréthane à 50 mW/m/K pour les laines les moins performantes, celle des PIV est d'environ 4 mW/m/K à l'état neuf. Cependant, comme tout isolant, leur performance se dégrade dans le temps. Cette diminution de conductivité thermique est davantage préjudiciable pour les PIV à cause de leur très bonne performance initiale et de leur coût encore élevé. Il convient donc d'étudier l'évolution de leur performance thermique sur l'ensemble de leur durée de vie dans le bâtiment, c'est à dire 50 ans. Pour cela la modélisation a été choisie comme outil car l'expérimentation ne peut satisfaire ces durées d'étude. L'étude du comportement thermique des PIV passe par différents axes de recherches intervenant à différentes échelles.Le premier concerne les mécanismes de transferts des gaz à travers les enveloppes des PIV, aussi appelés complexes barrières. L'enjeu est d'améliorer notre compréhension sur les relations qui existent entre les propriétés morphologiques des complexes barrières et les phénomènes de diffusion de la vapeur d'eau et de l'air sec à travers les différentes couches de matériaux qui constituent ces complexes barrières. Les résultats obtenus ne permettent pas encore de proposer un modèle de diffusion juste à cette échelle, mais mettent en avant certaines tendances et mécanismes physiques qui ouvrent de nouvelles pistes d'exploration.Le deuxième axe de recherche s'intéresse au comportement hygro-thermique à l'échelle des panneaux. Un modèle numérique de PIV a été développé afin de prendre en compte ses propriétés géométriques, thermiques et hydriques dans le calcul la performance thermique globale du panneau. Le modèle intègre le vieillissement du matériau de cœur par la modification de son isotherme de sorption à la vapeur d'eau. Des PIV fabriqués avec différents types de matériaux de cœur sont étudiés dans différentes conditions constantes en température et humidité. Les résultats des simulations permettent de mieux comprendre l'évolution de la conductivité thermique des PIV, d'analyser leur comportement global et de déterminer les principales caractéristiques qui sont déterminantes pour améliorer leur performance.Enfin, la troisième partie des travaux de recherche est consacrée au développement d'une méthode d'analyse de la performance des PIV en conditions réelles d'installation dans un bâtiment, dans différent climats français et plusieurs applications d'isolation. L'objectif est tout d'abord de déterminer les sollicitations réelles auxquelles sont soumis les PIV mis en œuvre, et ensuite de simuler leur comportement thermique à long terme afin de prédire leur performance moyenne. Les résultats donnent des températures et humidités qui sont très variables selon les climats, les systèmes d'isolation et les saisons de l'année, mais celles-ci restent finalement relativement modérées. La performance thermique moyenne des PIV sur 50 ans dépend très peu des applications, mais plus des climats et encore plus du type de silice qui constitue leur matériau de cœur. Contrairement à ce que laissent supposer les essais à court terme, les silices hydrophobes sont les plus favorables. Selon les applications et les climats, la conductivité thermique moyenne des PIV peut varier entre 4,7 et 7,3 mW/m/K. / Two types of thermal insulation materials exist for building application: the conventional insulation and the super-insulation materials which is characterized by an insulating performance higher than that of a simple layer of still air 25 mW/m/K). Vacuum Insulation Panels (VIP) belong to the second category. VIP is not a homogeneous material, but a product consisting of a core material maintained under vacuum by an envelope. The thermal performance of VIP is based on the nanoporous property of the core material and on the vacuum maintained by the envelope which has a very high gas barrier properties. While conventional insulation material has a thermal conductivity values from 21 mW/m/K for polyurethane foams to 50 mW/m/K for the worst wools, that of new VIPs is around 4 mW/m/K. Nevertheless, like every insulation materials, their performance degrades over time. This increase of thermal conductivity is even more detrimental for VIPs because of their very high initial performance and of their high cost. It is therefore important to study their thermal performance evolution over all their service-life in building, over 50 years. In order to manage this, modelling has been chosen, because experiments cannot be realised over such long periods. Studying the thermal performance of VIPs is going through different research topics which take place at different scales.The first one concerns the gas transfer mechanisms through the VIPs’ envelope, also called barrier complexes. The challenge is to improve our understanding of the relationship between the barrier complexes morphological properties and the water vapour and dry air diffusion phenomena through the different layers of materials which compose these barrier complexes. The results do not allow to provide a correct model at this scale, but put forward some trends and physical mechanisms that open up new avenues of exploration.The second research topic is focused on the hygro-thermal behaviour at panels’ scale. A numerical model of VIP has been developed in order to take into account its geometric, thermal and hygric properties in the global thermal performance calculation of the panel. The model integrates the ageing process of the core material by moving its water vapour sorption isotherm. VIPs made with different types of core material has been studied in different constant conditions of temperature and humidity. Simulation results allow to better understand the thermal conductivity evolution of VIPs, to analyse their global behaviour and to determine the main characteristics which are relevant to improve their performance.Then, the third part of the research studies is dedicated to the development of a method which allows to analyse the VIPs’ performance in real conditions of installation in building, in different French climate conditions and several insulation applications. The aim is first to determine the real solicitations imposed on VIP, and then to simulate their long-term thermal performance in order to predict their mean performance. Results show a large dispersion of solicitations submitted to VIPs according to the climate conditions and insulation systems. Temperatures and humidities are highly variable according to the seasons, but finally remain relatively moderate. It is turns out that the mean thermal performance of VIPs over 50 years differs little from applications, but more from climate conditions and even more from the type of silica used for the core material. Contrary to what the short term tests would suggest, hydrophobic silicas are most favourable. The mean thermal conductivity of VIPs can varies between 4.7 and 7.3 mW/m/K.
66

Kommunikationsgränssnitt mot GP&C transponder / Communication interface to a GP&C transponder

Johansson, Anders January 2002 (has links)
Examensarbetet som beskrivs i denna rapport handlar om en ny teknik för att förbättra säkerheten för flygplan i luften och i närheten av flygplatser. Denna teknik benämns ADS-B (Automatic Dependent Surveillance Broadcast), och är tänkt att göra det möjligt för piloter att själva få information om trafik i närområdet. Nuvarande system baserar sig i huvudsak på visuella observationer från flygledare i kontrolltorn samt radarspaning omkring flygplatserna. Med det nuvarande systemet kommer det att bli både dyrt och svårt att upprätthålla en acceptabel nivå på flygsäkerheten när trafiken ökar. Arbetet har bedrivits i AerotechTelubs regi i Linköping samt med hjälp ifrån företaget Sectra Wireless Technologies AB. Huvuddelen av arbetet inriktar sig på implementerandet av C-funktioner för att hantera kommunikationen och sammankopplandet av ett tidigare skapat system, för grafikvisning, med en transponder som hanterar ADS-B (tillverkad av Sectra). Målet med detta var att göra förberedande arbete åt AerotechTelub som de förhoppningsvis kommer att kunna använda i ett eventuellt kommande projekt. Rapporten tar upp några standarder som hör till konceptet GP&C (Global Positioning & Communication), samt beskriver de delar som ligger till grund för programmets funktion. Examensarbetet har resulterat i ett demonstrationsprogram för att visa hur en lösning av problemet kan se ut. Det har tyvärr inte gått att säkerställa om programmet fungerar till fullo, men genom simuleringar och andra tester har huvuddelen av programmets funktioner gått att verifiera.
67

Signalisation du VIP et du PACAP dans les monocytes humains Neuropeptides / PACAP/VIP signaling in human monocytes

El Zein, Nabil 17 October 2011 (has links)
PACAP et VIP sont deux peptides structuralement reliés qui appartiennent à la classe de neuropeptides comprenant la sécrétine, le glucagon et le growth hormone releasing factor. VIP et PACAP ont de nombreuses fonctions biologiques au niveau du système nerveux et sont considérés comme des agents neurotransmetteurs, sécrétagogues, neuroprotecteurs, neurotrophiques, mitogéniques et comme agents différenciant. <p><p>VIP et PACAP utilisés à des concentrations de l’ordre du nano-molaire sont décrits comme agents anti-inflammatoires. Dans cette thèse, nous montrons que les neuropeptides PACAP et VIP utilisés à des doses élevées de l’ordre du μ-molaire agissent également comme des molécules pro-inflammatoires au niveau des monocytes humains.<p><p>Nous montrons aussi qu’au sein des monocytes humains, le PACAP agit par l’intermédiaire du récepteur VPAC-1. Les voies de signalisation activées incluent de façon proximale la PLC et la PI3-kinase et de façon plus distale les voies ERK et p38 des MAP-Kinases et les voies dépendantes de focal adhésion kinase associées à la protéine du cytosquelette paxilline. PACAP induit également un pic calcique résultant d’une mobilisation intra- et extracellulaire de calcium.<p><p>Au niveau fonctionnel, nous montrons quelle PACAP augmente la production de radicaux libres et l’expression membranaire de l’intégrine CD11b impliquée dans l’adhésion et dans la régulation de nombreuses voies métaboliques.<p><p>Nous montrons également que de faibles doses de PACAP de l’ordre du nM sont suffisantes pour désensibiliser les monocytes à des concentrations plus importantes de PACAP, concentrations connues pour avoir un effet pro-inflammatoire. Le PACAP a ainsi un double rôle, anti-inflammatoire à faible dose et pro-inflammatoire à dose plus élevé.<p><p>Nous avons de plus investigué la présence d’une transactivation au niveau des cellules monocytaires. Dans ces cellules, PACAP comme rapporté dans les cellules neuronales, utilise la signalisation NGF/TrkA. PACAP augmente la fraction phosphorée du récepteur TrkA. L’utilisation d’inhibiteur spécifique du récepteur au NGF est associée à une diminution de la phosphorylation des voies PACAP-dépendantes telles que AKT et ERK. L’inhibiteur du récepteur au NGF diminue également la mobilisation calcique induite par le PACAP avec au niveau fonctionnel une diminution de la production de radicaux libres et de l’expression de l’intégrine CD11b. Enfin, l’observation que les voies métaboliques (ERK) et que les fonctions (production de radicaux libres) induites par le NGF au sein des cellules monocytaires est sensible à la pertussis toxine, agent modulant des récepteurs à protéines G, indique que les phénomènes de transactivation entre les voies PACAP/VPAC-1 et NGF/TrkA se font de façon bidirectionnelle.<p><p>Nous montrons enfin que ;à la fois PACAP et VIP sont des ligands du récepteur proinflammatoire FPRL1 au sein des monocytes induisant l’activation des voies AKT/ERK et la mobilisation calcique, responsables de l’augmentation d’expression de l’intégrine CD11b.Nous montrons cependant qu’il existe une voie propre au récepteur VPAC-1, indépendante de FPRL1, médiée par l’axe cAMP/PKA/p38 responsable spécifiquement d’une activité proinflammatoire avec sécrétion de MMP9 et augmentation membranaire de CD35. / Doctorat en Sciences / info:eu-repo/semantics/nonPublished
68

Energisimulering Av Äldre Flerbostadshus : En simulering av förbättringspotential i äldrefastigheter med hjälp av solceller, värmepumpar och tilläggsisolering.

Gilchrist, Oliver, Larsson, Emil January 2017 (has links)
I detta examenarbete har olika energieffektiviseringsåtgärder jämförts på två flerbostadshus i Ljungby kommun vars namn är Halfdan och Arngrim. I det första alternativet modulerades de befintliga byggnaderna för att kunna se dess totala energianvändning. Det andra alternativet består av att tilläggsisolera vindsvåningen samt byte av fönster och dörrar. Dessa åtgärder bidrar med en besparing på ca. 90 000 kWh/år Halfdan samt 55 000 kWh/år Arngrim. I det tredje alternativet installeras en frånluftsvärmepump samt en solcellsanläggning i vardera byggnad. Detta resulterar i en energibesparing på ca. 127 000 kWh/år i Halfdan samt 101 000 kWh/år i Arngrim.   Fastigheterna har simulerats i Energiberäkningar och VIP+ Energy, där resultatet påvisar att frånluftsvärmepumpen bidrar med den största energibesparingen i förhållande till det andra alternativet.
69

Energieffektivisering av flerbostadshus från miljonprogrammet / Energy efficiency of multi-family houses from the million homes programme

Cullsjö, Jonas, Ekman, Jonas, Östsjö, Johan January 2017 (has links)
I Sverige kvarstår cirka 650 000 bostäder i flerbostadshus uppförda under miljonprogrammet. Dessa byggnaders drift kräver stora mängder energi. Byggnaderna från den här eran står dessutom inom en snar framtid inför stora renoveringsbehov. I sambad med renovering är det därför viktigt att tänka energieffektivt och vidta extra åtgärder för att sänka dess energiförbrukning. I studien framgår att det finns goda möjligheter att sänka energianvändningen i dessa byggnader med åtgärder som kan vidtas i samband med renovering.
70

Malingsbo Herrgård : Energiberäkningar och åtgärdsförslag för en karolinsk 1700-talsgård / Malingsbo Estate : Energy calculations and suggestions for an 18th century Carolinian building

Nordström, Henrik January 2017 (has links)
Malingsbo Estate is a 18th century wooden building located in the small village of Malingsbo. Through the years, the estate has had a wide variation of usages. Today, almost 70 years since the last major renovation it is being utilized 6 weeks per year.   The following report, which has been made possible with the cooperation with the National Property Board (Statens Fastighetsverk) seeks to answer the following four questions. 1: What is the current climate inside the building 2: What are the resident’s views on the climate and the status of the building. 3: suggestions on how to, with the current building increase the period in which the inside climate is suitable for living. 4: Suggestions for lowering the energy usage for the building. These four points seeks to be answered with the following method: reports from Statens Fastighetsverk, surveys, field excursions and simulations in VIP-Energy.   The result of this report which should be especially considered is the following: At present time with no heating in the building, residents feel the climate during July to be acceptable to good, while during October most thinks it is to cold. For increasing the duration where the building meets a temperature of 20 degrees Celsius to 24 weeks’ installations of a 12500 W heating system is needed. For lowering the energy consumption without making large changes to the building two options should be specially considered: Insulation in the foundation with 50 mm insulation, and installation of window shutters during week 45 to 10. A larger installation suitable is solar panels for heating.

Page generated in 0.0312 seconds