Spelling suggestions: "subject:"cisual evaluation"" "subject:"4visual evaluation""
1 |
Virtual Reality for Scientific Visualization: an Exploratory Analysis of Presentation MethodsHetsel, Gene A. (Gene Arthur) 08 1900 (has links)
Humans are very effective at evaluating information visually. Scientific visualization is concerned with the process of presenting complex data in visual form to exploit this capability. A large array of tools is currently available for visual presentation. This research attempts to evaluate the effectiveness of three different presentation models that could be used for scientific visualization. The presentation models studied were, two-dimensional perspective rendering, field sequential stereoscopic three dimensional rendering and immersive virtual reality rendering. A large section of a three dimensional sub surface seismic survey was modeled as four-dimensional data by including a value for seismic reflectivity at each point in the survey. An artificial structure was randomly inserted into this data model and subjects were asked to locate and identify the structures. A group of seventeen volunteers from the University of Houston student body served as subjects for the study. Detection time, discrimination time and discrimination accuracy were recorded. The results showed large inter subject variation in presentation model preference. In addition the data suggest a possible gender effect. Female subjects had better overall performance on the task as well as better task acquisition.
|
2 |
[en] METROLOGICAL CONTROL OF LIGHTING IN STANDARDS BOOTHS FOR VISUAL APPRAISAL / [pt] CONTROLE METROLÓGICO DA ILUMINAÇÃO EM CABINES PADRONIZADAS DE AVALIAÇÃO VISUALMIGUEL DE FREITAS CHRISTINO 19 October 2004 (has links)
[pt] Não obstante os sofisticados avanços em tecnologias
ópticas, ainda não existem fontes de luz artificial
capazes de simular de forma adequada a luz do dia
natural. Alcançar um padrão de iluminação como este
representará uma redução nos custos de produção, em
função de retrabalhos gerados por avaliações visuais
pouco confiáveis, e nas divergências comerciais
relacionadas a produtos que têm como característica de
controle a cor, tais como artigos têxteis, gráficos, de
merchandising etc. A presente pesquisa de mestrado em
metrologia relaciona-se à avaliação metrológica das fontes
luminosas e cabines de iluminação disponíveis no mercado
e à sua adequação às normas que definem especificações
técnicas, com o propósito de estimular introdução de
inovação tecnológica em novos desenvolvimentos industriais
capazes de melhorar o desempenho desses aparatos. A
pesquisa contribui, também, com o desenvolvimento de um
diagnóstico do acervo de normas técnicas disponíveis
aplicáveis à padronização de sistemas de iluminação;
investigação de lâmpadas fluorescentes usualmente
utilizadas como simuladores de luz do dia e avaliação
metrológica de cabines de iluminação disponíveis no
mercado. Em particular, medições foram realizadas em um
sistema espectroradiométrico de alta definição, que
utiliza um monocromador duplo com capacidade de dispersão
do feixe de 2 nm/mm. Ensaios e análises de repetitividade
e reprodutibilidade conduzidas no sistema de medição
espectroradiométrico permitiu quantificar a variabilidade
associada a cada lote de fabricação dos simuladores de
luz do dia, comercializados na forma de lâmpadas
fluorescentes disponíveis no mercado nacional.
Caracterizada a variação da distribuição espectral ao
longo do eixo das fontes luminosas investigadas
(lâmpadas) foi possível desenvolver uma análise do impacto
induzido na uniformidade da iluminação obtida em cabines
industrializadas, assim definindo um fator de
diferenciação de interesse técnico e comercial. A
pesquisa revelou que nenhum dos simuladores de luz do dia
testados atingiu os requisitos mínimos estabelecidos para
a comparação visual de cores, quando avaliados com base
em normas e práticas internacionais. Foram ainda
realizadas medições para se verificar a influência dos
elementos construtivos das cabines na distribuição
espectral de potência na área de avaliação. Fundamentado
nas 1578 medições realizadas em condições laboratoriais
que simulam ambientes industriais, a pesquisa comprova
que alterações nas características construtivas das
cabines possuem impacto no resultado da classificação das
distribuições espectrais de potência, criando assim uma
condição facilitadora para que as especificações
normativas sejam atingidas, mesmo com a utilização de
lâmpadas fluorescentes disponíveis no mercado e de preço
reduzido. / [en] Notwithstanding the complex advances in optical
technologies, there are still no artificial light sources
capable of adequately simulating the natural daylight.
Reaching such a lighting standard will represent a
reduction of the production costs, in view of the rework
caused by not so reliable visual evaluations, and of the
commercial conflicts related to products that have colour
as one of their control characteristics, such as textile,
graphics and merchandising articles. The present Master
degree metrology research is related to the metrological
evaluation of the lighting sources and light booths
available in the market (commercially available), and to
their conformity to the technical specifications standards,
aiming to stimulate the introduction of technological
innovation to new industrial developments eligible to
enhance the performance of these apparatus. The research
has also contributed to the development of a diagnosis of
the collection of the existing technical standards applied
to the standardisation of lighting systems; to the
investigation of fluorescent lamps generally used as
daylight simulators, and to the metrological evaluation of
light booths available in the market (commercially
available). Particularly, analyses were done with a highly
precise spectroradiometric system that uses a double
monochromator with capacity for beam dispersion of 2 nm/mm.
Tests and analyses on repeatability and reproducibility
made with the spectroradiometric measurement system let to
quantify the variety associated with each manufactured set
of daylight simulators, commercialised as fluorescent lamps
available at the local market. Having the spectral
distribution determined throughout the axis of the studied
lighting sources (lamps) it was possible to develop an
analysis of the impact caused at the lighting uniformity
obtained for industrial light booths, and so, specifying a
distinctive factor technically and commercially
interesting. The research revealed that, when evaluated
considering the international practices and standards, none
of the daylight simulators tested achieved the minimum
requirement indicated for the visual comparison of colours.
In addition, measurements were done to verify the influence
of the light booths building pieces at the power spectral
distribution within the evaluation area. Based on 1578
measurements done at laboratorial conditions simulating
industrial environment, the research proves that changes
in the building characteristics of the light booths produce
an impact at the result of the power spectral distribution
classification, creating, thus, a smooth condition for the
attendance of the standards specifications, even when using
low-cost fluorescents lamps available in the market.
|
3 |
Estimativas de parâmetros genéticos de características de carcaça, medidas por ultrassonografia, e suas relações com escores visuais na raça Nelore /Gordo, Daniel Gustavo Mansan. January 2010 (has links)
Resumo: O objetivo deste trabalho foi estudar a variabilidade genética das características de carcaça obtidas por ultrassom e de escores visuais, bem como suas associações genéticas em bovinos da raça Nelore. Foram utilizados registros de 13.285, 13.061, 12.811, 3.484, 3.484, 3.483 e 3.303 animais, para área de olho de lombo (AOL), espessura de gordura subcutânea (EG), espessura de gordura subcutânea na garupa (EGP8), estrutura (E), precocidade (P), musculosidade (M) e umbigo (U), respectivamente. Considerou-se nas análises como o efeito fixo o grupo de contemporâneos, o efeito aleatório genético aditivo direto, além das covariáveis idade da vaca ao parto (efeitos linear e quadrático) e idade do animal (efeitos linear e quadrático), dependendo da característica. Foi utilizado como âncora nas análises 46.157 observações de peso padronizado aos 120 dias (P120). As estimativas dos componentes de (co)variâncias foram obtidas pelo método da máxima verossimilhança restrita aplicando um modelo animal em análise multicaracterística. As estimativas de herdabilidade para as características AOL, EG, EGP8, E, P, M e U foram de 0,33 ± 0,028, 0,24 ± 0,024, 0,28 ± 0,027, 0,24 ± 0,039, 0,38 ± 0,054, 0,29 ± 0,048 e 0,38 ± 0,063, respectivamente. As correlações genéticas entre os escores visuais e a área de olho de lombo foram positivas e moderadas, variando de 0,37 a 0,44. Estes valores indicam que a utilização da AOL como critério de seleção poderá produzir animais com maiores escores para essas características. As correlações entre P e M com as espessuras de gordura (EG e EGP8) apresentaram resultado semelhante. Entretanto, as correlações genéticas entre as espessuras de gordura e E variaram de -0,02 a 0,12. As correlações genéticas entre umbigo e estrutura, e umbigo e as características de carcaça indicam que as mesmas não são geneticamente associadas ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this work was to study the genetic variability for carcass traits obtained by ultrasound and visual scores traits, and their genetic relationship in Nelore cattle. A total of 13,285; 13,061; 12,811; 3,484; 3,484; 3,483 and 3,303 records of longissimus muscle area (LMA), backfat thickness (BF), obtained between the 12th and 13th ribs, rump fat thickness (RF), body structure score (E), precocity score (P), muscle score (M) and navel score (U) were utilized. The model included the fixed effect of contemporary group, the age of dam at calving and age of animal as covariable (linear and quadratic effects). The direct additive genetic effect was included as random effect in the model. The (co)variance components and genetic parameters estimates were obtained by the restricted maximum likelihood method, applying an animal model in multi-trait analyses. The heritability estimates for LMA, BF, RF, E, P, M and U were 0.33 ± 0.028, 0.24 ± 0.024, 0.28 ± 0.027, 0.24 ± 0.039, 0.38 ± 0.054, 0.29 ± 0.048 and 0.38 ± 0.063, respectively. The genetic correlation estimates between LMA with visual scores were positive and moderate, varying from 0.37 to 0.44. The genetic correlation estimates between backfat and rump fat with visual scores shown the same trend. However, the genetic correlation estimates between E with BF and RF were low, -0.02 to 0.12, respectively. These results shown that applying LMA as selection criteria will increase the visual scores. The genetic correlation estimates between U and E, and between U and carcass traits pointed out a weak relationship between these traits. Selection to improved carcass traits and E would not affect the navel score. Visual scores would not replace the carcass traits as selection criteria to improve the meat and carcass quality / Orientador: Lucia Galvão de Albuquerque / Coorientador: Fernando Sebastián Baldi Rey / Banca: Humberto Tonhati / Banca: Maria Eugênia Zerlotti Mercadante / Mestre
|
4 |
[en] METROLOGICAL AND INSTRUMENTAL EVALUATION CONTROL OF WHITE SAMPLES TREATED WITH FLUORESCENT WHITENING AGENTS / [pt] CONTROLE METROLÓGICO E INSTRUMENTAL DA AVALIAÇÃO DE AMOSTRAS BRANCAS TRATADAS COM ALVEJANTE ÓTICOJENNIFER KATHRIN GAY 21 June 2004 (has links)
[pt] A avaliação de artigos brancos tratados com alvejantes
ópticos, como eles são comuns em substratos têxteis,
plásticos e de papel, é uma tarefa que tradicionalmente
resulta em muitas divergências entre avaliações visuais
realizadas em uma cabine padronizada e avaliações
instrumentais realizadas com espectrofotômetros de
refletância. Mesmo entre as avaliações visuais ou entre as
avaliações instrumentais são encontradas diferenças muito
além do aceitável. Uma das principais causas é a
fluorescência dos alvejantes ópticos que é influenciada
pela quantidade de radiação UV em relação com a radiação
na faixa visível do espectro. O trabalho apresentado
analisa as diferentes formas de avaliação, principalmente
do ponto de vista da qualidade da distribuição espectral de
potência do simulador de luz do dia. No caso das avaliações
visuais, são testadas diferentes lâmpadas fluorescentes.
Para as avaliações instrumentais, a calibração e o ajuste
de UV em conjunto com as diferentes aberturas de medição
são analisados. O objetivo é aprimorar os aspectos
metrológicos da avaliação e contribuir para a sua
padronização a fim de garantir a maior reprodutibilidade de
resultados, um procedimento importante e almejado por todos
os segmentos industriais que utilizam os alvejantes ópticos. / [en] The evaluation of white objects treated with fluorescent
whitening agents, such as they are commonly found on
substrates like textiles, plastics and paper, is a task
that traditionally leads to frequent controversy between
the visual evaluations performed in a standardized light
booth and the instrumental evaluations performed on
reflectance spectrophotometers. Even between visual
or instrumental evaluations the differences encountered are
far beyond the acceptable. One of the main reasons is the
fluorescence of the optical brightening agents that is
influenced by the amount of UV radiation in relation to
the amount of radiation in the visible range of the
spectrum. The work presented analyses the different forms
of evaluation, mainly from the point of view of the
quality of the daylight simulators´ spectral power
distribution. In the case of the visual evaluations,
different fluorescent lamps are tested. For the instrumental
evaluations, the UV calibration and adjustment are analyzed
together with the different measurement apertures. The
objective is to improve the metrological aspects of the
evaluation and contribute to its standardization with the
aim to guarantee better reproducibility of results, an
important procedure that is desired by all the industrial
segments that use optical brighteners.
|
5 |
Estimativas de parâmetros genéticos de características de carcaça, medidas por ultrassonografia, e suas relações com escores visuais na raça NeloreGordo, Daniel Gustavo Mansan [UNESP] 23 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-02-23Bitstream added on 2014-06-13T18:29:30Z : No. of bitstreams: 1
gordo_dgm_me_jabo.pdf: 391188 bytes, checksum: ef5498968a5088b2fd921ea04eb139eb (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi estudar a variabilidade genética das características de carcaça obtidas por ultrassom e de escores visuais, bem como suas associações genéticas em bovinos da raça Nelore. Foram utilizados registros de 13.285, 13.061, 12.811, 3.484, 3.484, 3.483 e 3.303 animais, para área de olho de lombo (AOL), espessura de gordura subcutânea (EG), espessura de gordura subcutânea na garupa (EGP8), estrutura (E), precocidade (P), musculosidade (M) e umbigo (U), respectivamente. Considerou-se nas análises como o efeito fixo o grupo de contemporâneos, o efeito aleatório genético aditivo direto, além das covariáveis idade da vaca ao parto (efeitos linear e quadrático) e idade do animal (efeitos linear e quadrático), dependendo da característica. Foi utilizado como âncora nas análises 46.157 observações de peso padronizado aos 120 dias (P120). As estimativas dos componentes de (co)variâncias foram obtidas pelo método da máxima verossimilhança restrita aplicando um modelo animal em análise multicaracterística. As estimativas de herdabilidade para as características AOL, EG, EGP8, E, P, M e U foram de 0,33 ± 0,028, 0,24 ± 0,024, 0,28 ± 0,027, 0,24 ± 0,039, 0,38 ± 0,054, 0,29 ± 0,048 e 0,38 ± 0,063, respectivamente. As correlações genéticas entre os escores visuais e a área de olho de lombo foram positivas e moderadas, variando de 0,37 a 0,44. Estes valores indicam que a utilização da AOL como critério de seleção poderá produzir animais com maiores escores para essas características. As correlações entre P e M com as espessuras de gordura (EG e EGP8) apresentaram resultado semelhante. Entretanto, as correlações genéticas entre as espessuras de gordura e E variaram de -0,02 a 0,12. As correlações genéticas entre umbigo e estrutura, e umbigo e as características de carcaça indicam que as mesmas não são geneticamente associadas... / The objective of this work was to study the genetic variability for carcass traits obtained by ultrasound and visual scores traits, and their genetic relationship in Nelore cattle. A total of 13,285; 13,061; 12,811; 3,484; 3,484; 3,483 and 3,303 records of longissimus muscle area (LMA), backfat thickness (BF), obtained between the 12th and 13th ribs, rump fat thickness (RF), body structure score (E), precocity score (P), muscle score (M) and navel score (U) were utilized. The model included the fixed effect of contemporary group, the age of dam at calving and age of animal as covariable (linear and quadratic effects). The direct additive genetic effect was included as random effect in the model. The (co)variance components and genetic parameters estimates were obtained by the restricted maximum likelihood method, applying an animal model in multi-trait analyses. The heritability estimates for LMA, BF, RF, E, P, M and U were 0.33 ± 0.028, 0.24 ± 0.024, 0.28 ± 0.027, 0.24 ± 0.039, 0.38 ± 0.054, 0.29 ± 0.048 and 0.38 ± 0.063, respectively. The genetic correlation estimates between LMA with visual scores were positive and moderate, varying from 0.37 to 0.44. The genetic correlation estimates between backfat and rump fat with visual scores shown the same trend. However, the genetic correlation estimates between E with BF and RF were low, -0.02 to 0.12, respectively. These results shown that applying LMA as selection criteria will increase the visual scores. The genetic correlation estimates between U and E, and between U and carcass traits pointed out a weak relationship between these traits. Selection to improved carcass traits and E would not affect the navel score. Visual scores would not replace the carcass traits as selection criteria to improve the meat and carcass quality
|
6 |
Relationen mellan kontorsarbetares visuella trivsel i ljusmiljöer och en fysikalisk samt en perceptiv utvärdering / The relationship between office workers sense of visual well-being in light environments and a physical and perceptive evaluationOlsson, Nathalie, Pettersson, Hanna January 2021 (has links)
Syfte: Det råder brist på utvärderingar av belysningsanläggningar, vilket är ett viktigt verktyg för att få förståelse för brukares upplevelse, säkerställa en anläggnings kvalitet och förvärva kunskap till kommande projekt. Inomhusmiljön påverkar i hög grad människans hälsa och välbefinnande, där belysningen är en stor påverkningsfaktor. I samverkan med konsultföretaget WSP har utvärderingar genomförts i två kontorsmiljöer på Domstolsverket i Jönköping. Målet med studien var att undersöka hur en kvalitativ och kvantitativ utvärderingsmetod stod i relation till brukarnas uppfattningar av visuell trivsel. Metod: En kombination av kvalitativa och kvantitativa metoder användes för att förstå ljusmiljöns perceptiva och fysikaliska uppbyggnad, samt förstå brukarnas subjektiva uppfattning. Använda metoder var enkät, observation utifrån PERCIFAL och mätning av luminansförhållande. Resultat: Inga tydliga samband återfanns mellan brukarnas uppfattning av visuell trivsel och observation, eller analyserade. Svaga tendenser fanns dock på att i de områden observatörerna upplevde ljusare, var även respondenternas attityd till den visuella miljön mer positiv. Både höga och låga luminansförhållanden resulterade i att respondenterna erhöll en positiv attityd till den visuella miljön och välbefinnande. En positiv inställning till ljusmiljön visade sig gynna den visuella trivseln. Starkast samband fanns mellan inställning till ljusmiljön och upplevelsen av den visuella miljön, där en positiv inställning gynnade upplevelsen av den visuella miljön. Konsekvenser: Studiens slutsats är att varken en mätning eller observation är tillräcklig att användas enskilt för att säkerställa brukarnas visuella trivsel, eller för att beskriva hur ljusmiljön uppfattas av användarna. Därför rekommenderas det att inkludera brukare vid utvärdering, och att utföra mer omfattande utvärderingar för att generera kunskap kring kopplingen mellan mätbart ljus, perceptiv upplevelse och subjektiv uppfattning av visuell trivsel. Om utvärderingar och efterkontroller som även tar hänsyn till brukarnas subjektiva uppfattning prioriteras högre i byggprocessen, kan det säkerställa att ljusmiljöer erhåller ännu högre kvalitet. Begränsningar: Att enkäten utfördes på distans kan ha påverkat resultatet, samt att respondenterna ofta valde det neutrala mittenalternativet. Vissa begrepp kan även ha tolkats på annat sätt än förväntat. Observation och mätning utfördes endast vid ett tillfälle och inte i samtliga zoner där respondenterna var positionerade. Observation och mätning utgick endast från belysningens grundinställningar och bildskärmarna var inte tända vid detta tillfälle. Valet av antalet lokaler och skillnad i användningsfrekvens kan också ha påverkat resultatet. Mätning av luminans visade sig vara mer komplext än vad som förväntats. Intervjuer hade troligtvis givit en djupare förståelse kring det undersökta fenomenet än vad som generades från enkäten. Resultatet är enbart tillämpbart i det undersökta fallet och är därmed inte generellt giltigt. / Purpose: There is a shortage of evaluations of lighting constructions, which are crucial to understand the user, ensure the environmental quality and generate knowledge for future projects. The users’ well-being is affected by the indoor environmental quality, where the lighting has a major impact. In collaboration with the consulting company WSP, evaluations have been executed in two office environments at Domstolsverket in Jönköping. The aim with the study was to investigate how one qualitative and onequantitative evaluation method is related to the users’ perceptions of visual well-being. Method: A combination of qualitative and quantitative methods were used to understand the perceptive and physical construction of the lighting environment, and to understand the users’ subjective experience. Used methods were questionnaire, observation based on PERCIFAL and luminance ratio measuring. Findings: No significant connection were found between the users’ experience of visual well-being and the observation, or between the luminance ratios. There were weak tendencies that those areas of which the observers experienced the brightest, the users experienced the visual environment in a more positive way. Both high and low luminance ratios resulted in a positive attitude to the visual environment and the wellbeing. A positive attitude to the lighting environment favored the visual well-being. The strongest connections were found between the attitude to the lighting environment and the experience of the visual environment, where a positive attitude favored the experience of the visual environment the most. Implications: Since either the measuring or the observation hadn’t any connection to the users’ subjective experience, the conclusion of the study is that either luminance ratios or a visual evaluation individually are sufficient to ensure the users visual wellbeingor to describe how the lighting environment is experienced by the users.Therefore, it is recommended to include users in evaluations, and to execute more comprehensive evaluations to generate more knowledge regarding the connection between measurable light and perceptive and subjective experience of visual wellbeing. If this is included in the process, it might increase the quality of the lighting environment. Limitations: The questionnaire was responded to at a distance and the respondents tended to choose the neutral central option and those factors might have affected the result. Some terms might also have been interpreted in another way than expected. The observation and the measuring were only executed once, and not in all the areas where the respondents were positioned. While measuring and observing, only the most used light setting was used and the computer screens where not on. Luminance measuring was more complex than expected. Interviews might have given a deeper understanding about the investigated phenomenon than what was generated from the questionnaire.The result is only applicable in this specific case and therefore not universal.
|
Page generated in 0.0723 seconds