Correction de l'effet de volume partiel en tomographie d'émission par positrons chez le modelé animal

Guillette, Nicolas January 2011 (has links)
La quantification de la concentration de radiotraceur en imagerie par tomographie d'émission par positrons (TEP) est capitale, que ce soit au niveau clinique, mais majoritairement dans le domaine de la recherche, notamment pour l'analyse pharmacocinétique, appliquée chez l'humain et l'animal. Parmi les corrections importantes en imagerie TEP, l'effet de volume partiel (EVP) est l'un des plus complexes à corriger. Il dépend de divers phénomènes physiques liés aux performances de l'appareil, à la reconstruction de l'image ainsi qu'aux propriétés de l'objet mesuré.La correction pour l'EVP est cruciale afin de pallier la faible résolution spatiale de l'appareil TEP. Les conséquences principales de l'EVP sont une sous-estimation de la concentration d'un radiotraceur dans les objets de petite taille ainsi qu'une difficulté à cerner correctement les contours de l'objet observé. De nombreuses méthodes appliquées directement sur les images reconstruites sont proposées dans la littérature et sont utilisées dans certains cas, mais aucun consensus sur une méthode n'a encore été établi jusqu'à présent. Ce travail porte sur la compréhension de la problématique de l'EVP par différents tests mathématiques et des simulations, ainsi que sur le développement et l'application d'une nouvelle méthode de correction appliquée à l'imagerie TEP. L'argument principal de cette technique de correction est que le défaut de la résolution spatiale est enregistré au niveau des détecteurs et la correction pour ce défaut devrait être effectuée avant la reconstruction de l'image. En outre, la technique proposée a l'avantage de tenir compte non seulement de la taille, mais également de la forme de l'objet selon les différentes projections, ce qui représente un bénéfice par rapport aux approches appliquées directement sur l'image.La correction est basée sur la déconvolution des projections mesurées par des fonctions d'étalement appropriées. Celles-ci sont obtenues expérimentalement à partir de mires de cylindres de différents diamètres. Pour tester les capacités de cette technique, l'étude s'est limitée à la correction d'objets initialement isolés par régions d'intérêt sur l'image.La technique a ensuite été testée sur des images de tumeurs isolées et du coeur chez le rat, obtenues par injection de [indice supérieur 18] F-fluorodésoxy-D-glucose (FDG). Les conséquences de la correction de l'EVP ont enfin été étudiées par l'application du modèle d'analyse pharmacocinétique compartimentale du FDG dans le coeur de rat.
2

Modélisation, simulation et quantification de lésions athéromateuses en tomographie par émission de positons / Numerical modeling, simulation and quantification of atheromatous lesions in positron emission tomography

Huet, Pauline 06 July 2015 (has links)
Les pathologies cardio-vasculaires d’origine athéroscléreuse, premières causes de mortalité dans les pays occidentaux, sont insuffisamment prises en charge par les outils de dépistage et de suivi thérapeutique actuels. La Tomographie par Emission de Positons (TEP) est susceptible d’apporter au clinicien des outils puissants pour le diagnostic et le suivi thérapeutique des patients, en particulier grâce au traceur Fluorodésoxyglucose marqué au fluor 18 ([18F]-FDG). Cependant, l’Effet de Volume Partiel (EVP), dû notamment à la résolution spatiale limitée dans les images (plusieurs millimètres) en regard des faibles dimensions (de l’ordre du millimètre) des VOlumes d’Intérêt (VOIs), et les fluctuations statistiques du signal mesuré présentent des défis pour une quantification fiable.Un modèle original de lésion athéromateuse, paramétré par ses dimensions et sa concentration d’activité, a été développé et des simulations Monte-Carlo d’acquisitions TEP au [18F]-FDG de 36 lésions ont été produites. A partir des acquisitions simulées, nous avons montré que le nombre d’itérations des reconstructions itératives, le post-filtrage appliqué et le moyennage dans le VOI,paramètres relevés comme hautement variables dans une revue de la littérature dédiée, peuvent induire des variations des valeurs de fixation mesurées d’un facteur 1.5 à 4. Nous avons montré qu’une modélisation de la réponse du tomographe pouvait réduire le biais de mesure d’environ 10% par rapport au biais mesuré sur une image reconstruite avec un algorithme itératif standard et pour un niveau de bruit comparable. Sur les images reconstruites, nous avons montré que la fixation mesurée reste très biaisée (sous-estimation de plus de 50% du SUV réel) et dépend fortement des dimensions de la lésion à cause de l’EVP. Un contraste minimum de 4 par rapport à l’activité sanguine est nécessaire pour qu’une lésion soit détectée. Sans correction d’EVP, la mesure présente une corrélation faible avec la concentration d’activité, mais est très corrélée à l’activité totale dans la lésion. L’application d’une correction d’EVP fournit une mesure moins sensible à la géométrie de la lésion et plus corrélée à la concentration d’activité mais réduit la corrélation à l’activité totale dans la lésion.En conclusion, nous avons montré que l’intégralité de la fixation du [18F]-FDG dans les lésions athéromateuses inflammatoires totale peut être caractérisée sur les images TEP. Cette estimée ne requiert pas de correction de l’EVP. Lorsque la concentration d’activité dans la lésion est estimée, les mesures sont très biaisées à cause de l’EVP. Ce biais peut être réduit en mesurant le voxel d’intensité maximale, dans les images reconstruites sans post-filtrage avec au moins 80 itérations incluant un modèle de réponse du détecteur. La mise en œuvre d’une correction d’EVP facilite la détection des changements d’activité métabolique indépendamment de changements de dimensions de la zone siègede l’inflammation. Une quantification absolue exacte de la concentration d’activité dans les lésions ne sera possible que via une amélioration substantielle de la résolution spatiale des détecteurs TEP. / Cardiovascular disease is the leading cause of death in western countries. New strategies and tools for diagnosis and therapeutic monitoring need to be developed to manage patients with atherosclerosis, which is one major cause of cardiovascular disease. Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) is a powerful imaging technique that can detect at early stages plaques prone to rupture. Yet, Partial Volume Effect (PVE), due to the small lesion dimensions (around 1 mm) with respect to the scanner spatial resolution (around 6 mm full width at half maximum), and statistical variations considerably challenge the precise characterization of plaques from PET images. An original model of atheromatous lesion parameterized by its dimensions and activity concentration, was developed. Thirty six Monte Carlo simulations of FDG-PET acquisitions were produced. Based on the simulations, we showed that the number of iterations in iterative reconstructions, the post filtering of reconstructed images and the quantification method in the Volume Of Interests (VOI) varied sharply in an analysis of the dedicated literature. Changes in one of these parameters only could induce variations by a factor of 1.5 to 4 in the quantitative index. Overall, inflammation remained largely underestimated (> 50% of the real uptake). We demonstrated that modeling the detector response could reduce the bias by 10% of its value in comparison to a standard OSEM recontruction and for an identical level of noise. In reconstructed images, we showed that the measured values depended not only on the real uptake but also on the lesion dimensions because of PVE. A minimum contrast of 4 with respect to blood activity was required for the lesion to be observable. Without PVE correction, the measured values exhibited a correlation with activity concentration but were much more correlated with the total uptake in the lesion. Applying a PVE correction leads to an activity estimate that was less sensitive to the geometry of the lesion. The corrected values were more correlated to the activity concentration and less correlated to the total activity. In conclusion, we showed that the total activity in inflammatory lesions could be assessed in FDG-PET images. This estimate did not require PVE correction. Tracer concentration estimates are largely biased due to PVE, and the bias can be reduced by measuring the maximum voxel in the lesion in images reconstructed with at least 80 iterations and by modeling the detector response. Explicit PVE correction is recommended to detect metabolic changes independent of geometric changes. An accurate estimation of plaque uptake will however require the intrinsic spatial resolution of PET scanners to be improved.
3

Evaluation de l’integration des donnees issues de la tomographie par emission de positons en radiotherapie : application à deux modèles cliniques : les cancers ORL et les cancers pulmonaires / Assessment of the integration of positron emission tomography data in radiotherapy : application through two clinical model the head-and-neck cancers and the pulmonary cancers : the head-and-neck cancers and the pulmonary cancers

Henriques de Figueiredo, Bénédicte 17 December 2013 (has links)
Objectif : Etudier l’impact volumétrique et dosimétrique de l’intégration des données de tomographie par émission de positons (TEP) en radiothérapie (RT) à travers deux modèles cliniques : les cancers oto-rhino-laryngologiques (ORL) et les cancers pulmonaires. Matériel et méthodes : Pour les cancers ORL, après un travail préalable sur fantôme pour mise au point d’une méthode de segmentation automatique par seuillage adaptatif, deux séries de neuf et 15 patients présentant un cancer ORL traité par RT, ont bénéficié d’une TEP respectivement au 18F-Fluorodeoxyglucose (18F-FDG) et au 18F-Fluoromisonidazole (18F-FMISO), traceur de l’hypoxie. Les modifications volumétriques et dosimétriques induites par ces examens ont été analysées. Pour le 18F-FMISO, différents temps d’acquisition et différentes méthodes de segmentation ont également été étudiés. Pour les cancers pulmonaires, l’impact sur la RT d’une TEP-4D au 18F-FDG avec correction des effets de volume partiel (EVP) et application de différentes méthodes de segmentation, a été évalué à travers l’analyse des sept premiers patients inclus dans le protocole PULMOTEP, promu par le CHU de Bordeaux. Résultats : Pour les cancers ORL, la TEP au 18F-FDG a conduit à une réduction des volumes de RT de 40% tout en individualisant des zones de « mismatch » entre TEP et scanner. Pour la TEP au 18F-FMISO, un meilleur contraste des images était retrouvé à 4h. Cependant, les volumes segmentés à 3 et 4h n’étaient pas significativement différents, permettant d’envisager en pratique courante des acquisitions moins tardives à 3h. L’utilisation d’une TEP au 18F-FMISO permettait d’envisager la réalisation d’une « escalade de dose » sur les zones hypoxiques avec une augmentation du taux de probabilité de contrôle tumoral de 18,1% sans augmentation excessive de la toxicité. Pour les cancers pulmonaires, il n’était pas retrouvé d’impact de la correction du mouvement respiratoire, un seul patient sur les sept étudiés présentant une tumeur mobile. Un impact constant de la correction des EVP était par contre retrouvé avec une augmentation de l’activité tumorale maximale de 27% et une diminution des volumes segmentés de 15%.Conclusion : Pour les cancers ORL, la validation de ces résultats nécessite la réalisation d’études cliniques. Pour les cancers pulmonaires, l’utilisation d’une TEP-4D avec correction du mouvement respiratoire doit être envisagée au cas par cas. L’implémentation en clinique de logiciels de correction des EVP semble, par contre, à encourager. / Objective: To study the impact of Positron Emission Tomography (PET) data on radiotherapy (RT) planning through two clinical models: the head-and-neck cancers (HNC) and the pulmonary cancers. Methods and Materials: For HNC, after a previous phantom study in order to determinate an automatic segmentation method with adaptive thresholding, two series of nine and 15 patients selected for RT, underwent PET with 18F-Fluorodeoxyglucose (FDG) and 18F-Fluoromisonidazole (FMISO). The impact on RT target volumes (TV) and dosimetries was evaluated. For FMISO-PET, several time acquisitions and several segmentation methods were assessed. For pulmonary cancers, the use of a four-dimensional (4D) FDG-PET with partial volume effect (PVE) correction and several segmentation methods was evaluated through the first seven patients enrolled in the PULMOTEP protocol performed by the CHU of Bordeaux. Results: For HNC, FDG-PET led to a RT TV reduction of 40%, with mismatches between PET and CT data. For FMISO-PET images, a better contrast was obtained 4h after FMISO injection. However, segmented volumes obtained at 3 and 4h were not statistically different allowing PET- acquisitions at 3h in routine clinical practice. The use of FMISO-PET allows considering « dose escalation » on hypoxic TV with an increase of tumour control probability by 18,1% without excessive increase of toxicities. For pulmonary cancers, there was no impact of the respiratory motion correction but only one patient on seven presented a mobile tumour. PVE correction had impact on RT TV with an increase of the maximal tumoural activity by 27% and a volume reduction of 15%. Conclusion: For HNC, the validation of these results needs clinical and prospective studies. For pulmonary cancers, the use of 4D-PET must be decided case by case. On the other side, the implementation of automatic software for PVE correction seems interesting.
4

Caractérisation des tumeurs et de leur évolution en TEP/TDM au ¹⁸F-FDG pour le suivi thérapeutique

Maisonobe, Jacques-Antoine 13 December 2012 (has links) (PDF)
La Tomographie par Emission de Positons (TEP) au Fluoro-déoxyglucose marqué au Fluor 18 (¹⁸F-FDG), analogue du glucose, permet d'obtenir une image de la consommation de glucose dans l'organisme. La plupart des foyers tumoraux présentant une consommation excessive de glucose, son utilisation en oncologie permet d'améliorer la prise en charge des patients en diminuant le temps nécessaire pour évaluer l'efficacité des traitements tels que la chimiothérapie et la radiothérapie. Mon projet de recherche visait à proposer et améliorer des méthodes de quantification en TEP au ¹⁸F-FDG afin de caractériser au mieux l'évolution métabolique des volumes tumoraux.De nombreux facteurs biaisent la quantification en TEP. Parmi eux, l'Effet de Volume Partiel (EVP) reste difficile à corriger, notamment à cause de la faible résolution spatiale des images TEP. Afin de déterminer l'impact de la correction de l'EVP sur l'évaluation des réponses des tumeurs, une étude sur données simulées par Monte Carlo a tout d'abord été effectuée. Cette étude a été complétée par l'analyse de données TEP/TDM (Tomodensitométrie) acquises chez 40 patients atteints de cancers colorectaux métastatiques (CCM), traités par chimiothérapie à l'Institut Jules Bordet (Bruxelles). L'analyse de 101 tumeurs a montré que les critères tels que le SUV, n'incluant pas de correction de l'EVP, et qui reflètent alors le volume tumoral et son activité, prédisaient mieux l'évolution tumorale que les critères corrigés de l'EVP. Compte tenus des résultats prometteurs récents de méthodes de caractérisation de l'hétérogénéité de la fixation du FDG dans les tumeurs, un second volet de notre travail a consisté à étudier l'intérêt de la prise en compte de la texture dans le cadre du suivi thérapeutique. L'application de l'analyse de texture aux cas de CCM étudiés précédemment n'a pas permis de démontrer une valeur ajoutée des indices de texture par rapport aux index quantitatifs couramment employés en clinique. Nous avons montré que cette conclusion s'expliquait en partie par la non-robustesse des indices de texture vis-à-vis des paramètres impliqués dans leur mesure. Nous avons enfin cherché à évaluer une méthode d'Analyse Factorielle de Séquences d'Images Médicales (AFSIM), appliquée au contexte du suivi thérapeutique, pour caractériser l'évolution tumorale tout au long du traitement. Cette étude a porté sur 9 séries de 4 à 6 examens TEP/TDM de patients traités par radiothérapie au Centre Hospitalier Universitaire Henri Becquerel de Rouen. Outre l'information visuelle globale apportée par cette méthode, l'analyse quantitative des résultats obtenus a permis de caractériser l'hétérogénéité de la réponse vue par l'AFSIM. L'échec des index classiques, provenant entre autres de leur incapacité à distinguer les processus inflammatoires de l'activité métabolique tumorale, a permis de monter la valeur ajoutée de l'AFSIM par rapport aux index tels que le SUV maximal ou moyen.
5

Étude des effets de volume partiel en IRM cérébrale pour l'estimation d'épaisseur corticale / Partial volume effets in brain MRI for cortical thickness estimation

Duché, Quentin 18 June 2015 (has links)
Les travaux réalisés dans cette thèse se situent à l'interface des domaines de l'acquisition en imagerie par résonance magnétique (IRM) et du traitement d'image pour l'analyse automatique des structures cérébrales. La mesure de modifications structurelles telles que l'atrophie corticale nécessite l'application d'algorithmes de traitement d'image. Ceux-ci doivent compenser les artefacts en IRM tels que l'inhomogénéité du signal ou les effets de volume partiel (VP) pour permettre la segmentation des tissus cérébraux puis l'estimation d'épaisseur corticale. Nous proposons une nouvelle modélisation de VP proche de la physique de l'acquisition baptisée modèle bi-exponentiel qui vient concurrencer le traditionnel modèle linéaire. Il nécessite l'utilisation de deux images de contrastes différents parfaitement recalées. Ce modèle a été validé sur des simulations et des fantômes physique et numérique dans un premier temps. Parallèlement, la récente séquence MP2RAGE permet d'acquérir deux images co-recalées par acquisition et leur combinaison aboutit à l'obtention d'une image insensible aux inhomogénéités du signal et d'une carte de T1 des tissus imagés. Nous avons testé notre modèle sur des données in vivo MP2RAGE et avons montré que l'application du modèle linéaire de VP conduit à une sous-estimation systématique de la substance grise à l'échelle du voxel. Ces erreurs se propagent à l'estimation d'épaisseur corticale, biomarqueur très sensible aux effets de VP. Nos résultats plaident en faveur de l'hypothèse suivante : la modélisation de VP pour les images MP2RAGE doit être différente de celle employée pour des images obtenues avec des séquences plus classiques. Le modèle bi-exponentiel est une solution adaptée à cette séquence particulière. / The work developed in this thesis is within the scope of magnetic resonance imaging (MRI) acquisition and image processing for the automated analysis of brain structures. The measurement of structural modifications with time such as cortical atrophy requires the application of image processing algorithms. They must compensate for MRI artifacts such as intensity inhomogeneities or partial volume (PV) effects to allow for brain tissues segmentation then cortical thickness estimation. We suggest a new PV model relying on the physics of acquisition named bi-exponential model that differs from the commonly used linear model by modelling brain tissues and image acquisition. It requires the use of two differently contrasted and perfectly coregistered images. This model has been validated with simulations and physical and digital phantoms in a first place. In parallel, the recent MP2RAGE sequence provides two coregistered images and their combination results in a bias-field corrected image as well as a T1 map of the scanned tissues. We tested our model with in vivo MP2RAGE data and demonstrated that using the linear PV model leads to a systematic gray matter proportion underestimation in PV voxels. These errors result in cortical thickness underestimation. Our results favor the following assumption: PV modelling with MP2RAGE images must differ from the usual linear PV model applied for images obtained from more classic sequences. The bi-exponential model is an adapted solution to this particular sequence.
6

Caractérisation des tumeurs et de leur évolution en TEP/TDM au ¹⁸F-FDG pour le suivi thérapeutique / Characterization of the tumors and their evolutions using PET/CT for treatment following

Maisonobe, Jacques-Antoine 13 December 2012 (has links)
La Tomographie par Emission de Positons (TEP) au Fluoro-déoxyglucose marqué au Fluor 18 (¹⁸F-FDG), analogue du glucose, permet d'obtenir une image de la consommation de glucose dans l'organisme. La plupart des foyers tumoraux présentant une consommation excessive de glucose, son utilisation en oncologie permet d'améliorer la prise en charge des patients en diminuant le temps nécessaire pour évaluer l'efficacité des traitements tels que la chimiothérapie et la radiothérapie. Mon projet de recherche visait à proposer et améliorer des méthodes de quantification en TEP au ¹⁸F-FDG afin de caractériser au mieux l'évolution métabolique des volumes tumoraux.De nombreux facteurs biaisent la quantification en TEP. Parmi eux, l'Effet de Volume Partiel (EVP) reste difficile à corriger, notamment à cause de la faible résolution spatiale des images TEP. Afin de déterminer l'impact de la correction de l’EVP sur l’évaluation des réponses des tumeurs, une étude sur données simulées par Monte Carlo a tout d’abord été effectuée. Cette étude a été complétée par l’analyse de données TEP/TDM (Tomodensitométrie) acquises chez 40 patients atteints de cancers colorectaux métastatiques (CCM), traités par chimiothérapie à l'Institut Jules Bordet (Bruxelles). L’analyse de 101 tumeurs a montré que les critères tels que le SUV, n’incluant pas de correction de l'EVP, et qui reflètent alors le volume tumoral et son activité, prédisaient mieux l’évolution tumorale que les critères corrigés de l’EVP. Compte tenus des résultats prometteurs récents de méthodes de caractérisation de l’hétérogénéité de la fixation du FDG dans les tumeurs, un second volet de notre travail a consisté à étudier l’intérêt de la prise en compte de la texture dans le cadre du suivi thérapeutique. L’application de l’analyse de texture aux cas de CCM étudiés précédemment n’a pas permis de démontrer une valeur ajoutée des indices de texture par rapport aux index quantitatifs couramment employés en clinique. Nous avons montré que cette conclusion s’expliquait en partie par la non-robustesse des indices de texture vis-à-vis des paramètres impliqués dans leur mesure. Nous avons enfin cherché à évaluer une méthode d’Analyse Factorielle de Séquences d’Images Médicales (AFSIM), appliquée au contexte du suivi thérapeutique, pour caractériser l’évolution tumorale tout au long du traitement. Cette étude a porté sur 9 séries de 4 à 6 examens TEP/TDM de patients traités par radiothérapie au Centre Hospitalier Universitaire Henri Becquerel de Rouen. Outre l’information visuelle globale apportée par cette méthode, l’analyse quantitative des résultats obtenus a permis de caractériser l’hétérogénéité de la réponse vue par l’AFSIM. L’échec des index classiques, provenant entre autres de leur incapacité à distinguer les processus inflammatoires de l’activité métabolique tumorale, a permis de monter la valeur ajoutée de l’AFSIM par rapport aux index tels que le SUV maximal ou moyen. / Positron Emission Tomography (PET) using ¹⁸F-FluoroDeoxyGlucose (¹⁸F-FDG), a radiolabelled analogue of the glucose, is used to get an image of the glucose consumption in the body. As most tumor masses show a high glucose consumption, PET is widely used in oncology for diagnosis and patient monitoring. In the context of patient monitoring, the motivation is to decrease the time interval needed to assess treatment (radiotherapy or chemotherapy efficieny) compared to therapeutic follow-up based only on anatomic imaging only (Computed Tomography or Magnetic Resonance Imaging). My research project aimed at proposing and improving quantitative methods in FDG-PET to better characterize tumor evolution.In PET, many factors affect the accuracy of parameters estimated from the images. Among them, Partial Volume Effect (PVE) remains difficult to correct, mainly due to the low spatial resolution of PET images. To determine the impact of PVE on treatment response evaluation, a preliminary study was performed using Monte Carlo simulated PET scans. An additional study was conducted based on the analysis of the PET/CT (Computed Tomography) data of 40 Metastatic Colorectal Cancer (MCC) patients treated with chemotherapy at the Jules Bordet Institute (Brussels, Belgium). The analysis of the 101 tumors showed that criteria such as the Standardized Uptake Value (SUV), which does not include PVE correction, were better predictors of tumors evolutions than PVE corrected criteria. This is because without PVE correction, SUV includes information on both metabolic volume and metabolic activity, which are two relevant pieces of information to characterize the tumor. A second part of our work was to study the potential of tumor texture analysis in patient monitoring, following promising results reported in the literature. Texture analysis was applied to the MMC patients data previously mentioned but did allow to a better segregation of tumors responses as compared to indices currently used in the clinics. We found that this was partly due to the lack of robustness of the textures indices.Finally, we evaluated a Factor Analysis in Medical Images Series (FAMIS) method to characterize tumor evolution during treatment. This study focused on 9 series of 4 to 6 PET/CT scans acquired all along the radiotherapy/radio-chemotherapy of patients treated at the Centre Hospitalier Universitaire Henri Becquerel (Rouen, France). In addition to the rich visual information brought by this method, a quantitative analysis of the results made it possible to characterize response heterogeneity as seen using FAMIS. In particular, FAMIS clearly demonstrated the occurrence of inflammatory processes. In addition, due to the low metabolic activity of the tumors at the end of the treatment, many conventional indices could not describe the tumor changes, while FAMIS gave a full assessment of the tumor change over time.
7

Reconstruction 4D intégrant la modélisation pharmacocinétique du radiotraceur en imagerie fonctionnelle combinée TEP/TDM / 4D reconstruction including radiopharmaceutical modeling in PET/CT imaging

Merlin, Thibaut 11 December 2013 (has links)
L'imagerie TEP permet de mesurer et visualiser les changements de la distribution biologique des radiopharmaceutiques au sein des organes d'intérêt au court du temps. Ce suivi temporel offre des informations très utiles concernant les processus métaboliques et physiologiques sous-jacents, qui peuvent être extraites grâce à différentes techniques de modélisation cinétique. De plus, un autre avantage de la prise en compte de l'information temporelle dans les acquisitions TEP pour les examens en oncologie thoracique concerne le suivi des mouvements respiratoires. Ces acquisitions permettent de mettre en place des protocoles et des méthodologies visant à corriger leurs effets néfastes à la quantification, et les artefacts associés. L'objectif de ce projet est de développer une méthode de reconstruction permettant de combiner et mettre en oeuvre d'une part les corrections nécessaires à la quantification des données en TEP, et d'autre part la modélisation de la biodistribution du radiotraceur au cours du temps permettant d'obtenir des images paramétriques pour l'oncologie thoracique. Dans un premier temps, une méthodologie de correction des effets de volume partiel intégrant, dans le processus de reconstruction, une déconvolution de Lucy-Richardson associée à un débruitage dans le domaine des ondelettes, a été proposée. Une seconde étude a été consacrée au développement d'une méthodologie combinant une régularisation temporelle des données par l'intermédiaire d'un ensemble de fonctions de base temporelles, avec une méthode de correction des mouvements respiratoires basée sur un modèle élastique. Enfin, dans une troisième étape, le modèle cinétique de Patlak a été intégré dans un algorithme de reconstruction dynamique, et associé à la correction de mouvement afin de permettre la reconstruction directe d'images paramétriques de données thoraciques soumises au mouvement respiratoire. Les paramètres de transformation élastique pour la correction de mouvement ont été calculés à partir des images TEP d'intervalles synchronisés par rapport à l'amplitude de la respiration du patient. Des simulations Monte-Carlo d'un fantôme 4D géométrique avec plusieurs niveaux de statistiques, et du fantôme anthropomorphique NCAT intégrant des courbes d'activités temporelles réalistes pour les différents tissus, ont été réalisées afin de comparer les performances de la méthode de reconstruction paramétrique développée dans ce travail avec une approche 3D standard d'analyse cinétique. L'algorithme proposé a ensuite été testé sur des données cliniques de patients présentant un cancer bronchique non à petites cellules. Enfin, après la validation indépendante de l'algorithme de correction des effets de volume partiel d'une part, et de la reconstruction 4D incorporant la régularisation temporelle d'autre part, sur données simulées et cliniques, ces deux méthodologies ont été associées afin d'optimiser l'estimation de la fonction d'entrée à partir d'une région sanguine des images reconstruites. Les résultats de ce travail démontrent que l'approche de reconstruction paramétrique proposée permet de conserver un niveau de bruit stable dans les régions tumorales lorsque la statistique d'acquisition diminue, contrairement à l'approche d'estimation 3D pour laquelle le niveau de bruit constaté augmente. Ce résultat est intéressant dans l'optique d'une réduction de la durée des intervalles de la reconstruction 4D, permettant ainsi de réduire la durée totale de l'acquisition 4D. De plus, l'utilisation des fonctions d'entrée estimées avec les méthodes de régularisation temporelle proposées ont conduit à améliorer l'estimation des paramètres de Patlak. Enfin, la correction élastique du mouvement amène à une diminution du biais d'estimation des deux paramètres de Patlak, en particulier sur les tumeurs de petites dimensions situées dans des régions sensibles au mouvement respiratoire. / Positron emission tomography (PET) is now considered as the gold standard and the main tool for the diagnosis and therapeutic monitoring of oncology patients, especially due to its quantitative aspects. With the advent of multimodal imaging in combined PET and X-ray CT systems, many methodological developments have been proposed in both pre-processing and data acquisition, image reconstruction, as well as post-processing in order to improve the quantification in PET imaging. Another important aspect of PET imaging is its high temporal resolution and ability to perform dynamic acquisitions, benefiting from the high sensitivity achieved with current systems. PET imaging allows measuring and visualizing changes in the biological distribution of radiopharmaceuticals within the organ of interest over time. This time tracking provides valuable information to physicians on underlying metabolic and physiological processes, which can be extracted using pharmacokinetic modeling. The objective of this project is, by taking advantage of dynamic data in PET/CT imaging, to develop a reconstruction method combining in a single process all the correction methodology required to accurately quantify PET data and, at the same time, include a pharmacokinetic model within the reconstruction in order to create parametric images for applications in oncology. In a first step, a partial volume effect correction methodology integrating, within the reconstruction process, the Lucy-Richardson deconvolution algorithm associated with a wavelet-based denoising method has been introduced. A second study focused on the development of a 4D reconstruction methodology performing temporal regularization of the dataset through a set of temporal basis functions, associated with a respiratory motion correction method based on an elastic deformation model. Finally, in a third step, the Patlak kinetic model has been integrated in a dynamic image reconstruction algorithm and associated with the respiratory motion correction methodology in order to allow the direct reconstruction of parametric images from dynamic thoracic datasets affected by the respiratory motion. The elastic transformation parameters derived for the motion correction have been estimated from respiratory-gated PET images according to the amplitude of the patient respiratory cycle. Monte-carlo simulations of two phantoms, a 4D geometrical phantom, and the anthropomorphic NCAT phantom integrating realistic time activity curves for the different tissues, have been performed in order to compare the performances of the proposed 4D parametric reconstruction algorithm with a standard 3D kinetic analysis approach. The proposed algorithm has then been assessed on clinical datasets of several patients with non small cell lung carcinoma. Finally, following the prior validation of the partial volume effect correction algorithm on one hand, and the 4D reconstruction incorporating the temporal regularization on the other hand, on simulated and clinical datasets, these two methodologies have been associated within the 4D reconstruction algorithm in order to optimize the estimation of image derived input functions. The results of this work show that the proposed direct parametric approach allows to maintain a similar noise level in the tumor regions when the statistic decreases, contrary to the 3D estimation approach for which the observed noise level increases. This result suggests interesting perspectives for the reduction of frame duration reduction of 4D reconstruction, allowing a reduction of the total 4D acquisition duration. In addition, the use of input function estimated with the developed temporal regularization methods led to the improvement of the Patlak parameters estimation. Finally, the elastic respiratory motion correction led to a diminution of the estimation bias of both Patlak parameters, in particular for small lesions located in regions affected by the respiratory motion.
8

Correction des effets de volume partiel en tomographie d'émission

Le Pogam, Adrien 29 April 2010 (has links)
Ce mémoire est consacré à la compensation des effets de flous dans une image, communément appelés effets de volume partiel (EVP), avec comme objectif d’application l’amélioration qualitative et quantitative des images en médecine nucléaire. Ces effets sont la conséquence de la faible résolutions spatiale qui caractérise l’imagerie fonctionnelle par tomographie à émission mono-photonique (TEMP) ou tomographie à émission de positons (TEP) et peuvent être caractérisés par une perte de signal dans les tissus présentant une taille comparable à celle de la résolution spatiale du système d’imagerie, représentée par sa fonction de dispersion ponctuelle (FDP). Outre ce phénomène, les EVP peuvent également entrainer une contamination croisée des intensités entre structures adjacentes présentant des activités radioactives différentes. Cet effet peut conduire à une sur ou sous estimation des activités réellement présentes dans ces régions voisines. Différentes techniques existent actuellement pour atténuer voire corriger les EVP et peuvent être regroupées selon le fait qu’elles interviennent avant, durant ou après le processus de reconstruction des images et qu’elles nécessitent ou non la définition de régions d’intérêt provenant d’une imagerie anatomique de plus haute résolution(tomodensitométrie TDM ou imagerie par résonance magnétique IRM). L’approche post-reconstruction basée sur le voxel (ne nécessitant donc pas de définition de régions d’intérêt) a été ici privilégiée afin d’éviter la dépendance aux reconstructions propres à chaque constructeur, exploitée et améliorée afin de corriger au mieux des EVP. Deux axes distincts ont été étudiés. Le premier est basé sur une approche multi-résolution dans le domaine des ondelettes exploitant l’apport d’une image anatomique haute résolution associée à l’image fonctionnelle. Le deuxième axe concerne l’amélioration de processus de déconvolution itérative et ce par l’apport d’outils comme les ondelettes et leurs extensions que sont les curvelets apportant une dimension supplémentaire à l’analyse par la notion de direction. Ces différentes approches ont été mises en application et validées par des analyses sur images synthétiques, simulées et cliniques que ce soit dans le domaine de la neurologie ou dans celui de l’oncologie. Finalement, les caméras commerciales actuelles intégrant de plus en plus des corrections de résolution spatiale dans leurs algorithmes de reconstruction, nous avons choisi de comparer de telles approches en TEP et en TEMP avec une approche de déconvolution itérative proposée dans ce mémoire. / Partial Volume Effects (PVE) designates the blur commonly found in nuclear medicine images andthis PhD work is dedicated to their correction with the objectives of qualitative and quantitativeimprovement of such images. PVE arise from the limited spatial resolution of functional imaging witheither Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography(SPECT). They can be defined as a signal loss in tissues of size similar to the Full Width at HalfMaximum (FWHM) of the PSF of the imaging device. In addition, PVE induce activity crosscontamination between adjacent structures with different tracer uptakes. This can lead to under or overestimation of the real activity of such analyzed regions. Various methodologies currently exist tocompensate or even correct for PVE and they may be classified depending on their place in theprocessing chain: either before, during or after the image reconstruction process, as well as theirdependency on co-registered anatomical images with higher spatial resolution, for instance ComputedTomography (CT) or Magnetic Resonance Imaging (MRI). The voxel-based and post-reconstructionapproach was chosen for this work to avoid regions of interest definition and dependency onproprietary reconstruction developed by each manufacturer, in order to improve the PVE correction.Two different contributions were carried out in this work: the first one is based on a multi-resolutionmethodology in the wavelet domain using the higher resolution details of a co-registered anatomicalimage associated to the functional dataset to correct. The second one is the improvement of iterativedeconvolution based methodologies by using tools such as directional wavelets and curveletsextensions. These various developed approaches were applied and validated using synthetic, simulatedand clinical images, for instance with neurology and oncology applications in mind. Finally, ascurrently available PET/CT scanners incorporate more and more spatial resolution corrections in theirimplemented reconstruction algorithms, we have compared such approaches in SPECT and PET to aniterative deconvolution methodology that was developed in this work.