Berechnen der Größe von Wasserspeichern zum saisonalen Speichern von Wärme bei der ausschließlichen Wärmeversorgung von Häusern mit Solarkollektoren

Al-Addous, Mohammad 20 July 2009 (has links) (PDF)
Es wird ermittelt, welches Volumen Wasserspeicher besitzen müssen, die bei der ausschließlichen Wärmeversorgung von Häusern mit Wärme, die mit Hilfe von Solarkollektoren gewonnen wird, Wärme im Sommer einspeichern und im Winter entspeichern. Den Berechnungen liegen Messungen über die nutzbare Solarwärme zugrunde. Betrachtet werden Wohnhäuser mit Erdgeschoss und Dachgeschoss mit Wohnflächen von 115 m2, 150 m2 und 200 m2. Die spezifischen Wärmeverbräuche der Gebäude liegen zwischen 175 und 50 kWh/(m2.Jahr). Die Solarkollektorflächen variieren zwischen 9 m2 und 100 m2. Die Speicherfähigkeit des Wassers definierende Temperaturspreizung in den Speichern zwischen kalter Seite unten und warmer Seite oben beträgt einmal 50 K und zum anderen 60 K. Es werden Speicherwirkungsgrade von 100%, 90% und 80% zugrunde gelegt. Im günstigsten Fall errechnen sich für drei Hausgrößen von 115 m2, 150 m2 und 200 m2 Wasserspeicher Volumina von 5,7 m3, 6,25 m3 bzw. 8 m3.
2

Berechnen der Größe von Wasserspeichern zum saisonalen Speichern von Wärme bei der ausschließlichen Wärmeversorgung von Häusern mit Solarkollektoren

Al-Addous, Mohammad 13 July 2006 (has links)
Es wird ermittelt, welches Volumen Wasserspeicher besitzen müssen, die bei der ausschließlichen Wärmeversorgung von Häusern mit Wärme, die mit Hilfe von Solarkollektoren gewonnen wird, Wärme im Sommer einspeichern und im Winter entspeichern. Den Berechnungen liegen Messungen über die nutzbare Solarwärme zugrunde. Betrachtet werden Wohnhäuser mit Erdgeschoss und Dachgeschoss mit Wohnflächen von 115 m2, 150 m2 und 200 m2. Die spezifischen Wärmeverbräuche der Gebäude liegen zwischen 175 und 50 kWh/(m2.Jahr). Die Solarkollektorflächen variieren zwischen 9 m2 und 100 m2. Die Speicherfähigkeit des Wassers definierende Temperaturspreizung in den Speichern zwischen kalter Seite unten und warmer Seite oben beträgt einmal 50 K und zum anderen 60 K. Es werden Speicherwirkungsgrade von 100%, 90% und 80% zugrunde gelegt. Im günstigsten Fall errechnen sich für drei Hausgrößen von 115 m2, 150 m2 und 200 m2 Wasserspeicher Volumina von 5,7 m3, 6,25 m3 bzw. 8 m3.
3

Solare Fernwärme für das Quartier Brühl in Chemnitz – Begleitforschung (SolFW): Abschlussbericht zum Forschungsvorhaben

Urbaneck, Thorsten, Lal Shrestha, Nirendra, Oppelt, Thomas, Frotscher, Ophelia, Göschel, Thomas, Uhlig, Ulf, Frey, Holger 28 April 2020 (has links)
Die Professur Technische Thermodynamik der TU Chemnitz und die inetz (Netzbetreiber) haben unter technischen und wirtschaftlichen Gesichtspunkten ein hocheffizientes solares Fernwärmesystem (2100 m² Kollektorfläche, 1000 m³ Speicher, max. Netzlast 6-14 MW) für den Stadtteil Brühl in Chemnitz entwickelt. Dieses zeichnet sich durch viele innovative Merkmale (Systemkonzept und -betrieb, Speicher, Hausanschlussstation) aus und berücksichtigt komplexe städtische bzw. gesellschaftliche Zusammenhänge (Akzeptanz, Städtebau, Denkmalschutz, Gebäudeeigentümer, bestehende Versorgungssysteme). In diesem Projekt wurde eine breit angelegte Begleitforschung zur Funktion des Systems durchgeführt. Das Projekt umfasste u. a. die Datenbeschaffung und -auswertung bzgl. des Systems und des Quartiers, die Datenübernahme von der inetz, die Datenverarbeitung und -auswertung sowie die Optimierung des Systems. Es erfolgten spezielle Untersuchungen zur Funktion der Kollektorfelder, des Zwei-Zonen-Speichers, des Nachheizsystems und einer Hausanschlussstation. Aufgrund des Einsatzes von Wasser im gesamten System wurden die Untersuchungen in den Kollektorfeldern mit einem speziellen bzw. mobilen Monitoring realisiert. Numerische Simulationen lieferten das theoretische Verhalten für einen Soll-Ist-Ver gleich. Umgekehrt konnten die Simulationen anhand der Messwerte validiert werden. Die Mess- und Simulationsergebnisse flossen danach in Metamodelle ein. Diese Metamodelle wurden im SolFW-Tool genutzt, um eine einfache und schnelle Berechnung von solaren Fernwärmesystemen in Quartieren zur Verfügung zu stellen. Das SolFW-Tool ist als webbasiertes Simulationsprogramm verfügbar.
4

Geothermie / Geothermal Energy. Initial stages for the utilisation of renewable energy sources in the GDR

Eichkorn, Florian 26 January 2016 (has links) (PDF)
Ende der 1970er Jahre sah sich die SED in der DDR gezwungen angesichts hoher Auslandsverschuldung und gestiegener Importpreise für fossile Energieträger stärker in heimische Energiequellen und rationellere Energieanwendung zu investieren. In diesem Kontext und um Anschluss an die internationale Entwicklung zu halten wurde Ende der 1970er und in den 1980er Jahren die Nutzung oberflächennaher und tiefer Geothermie gefördert. Im Rahmen dieser Arbeit wird neben einer chronologischen Darstellung der Geothermieförderung in der DDR eine Einordnung in deren Energiepolitik, der Wärmeversorgung und der Förderung anderer erneuerbarer Energien geleistet. Aufgrund des geringen historischen Forschungsstandes zur Geothermie und der Wärmeversorgung in der DDR allgemein wurde dieser Arbeit ein explorativer Ansatz zugrunde gelegt. Als Quellenbasis dienten unter anderem Artikel aus wissenschaftlichen Zeitschriften der DDR und verschiedene Archivbestände. Ende der 1970er Jahre bis 1983 versuchte die SED den Einsatz von Wärmepumpen für die Wärmeversorgung zu fördern. Obwohl zahlreiche Pilotprojekte wie die Wärmepumpenheizzentrale Dresden fertiggestellt wurden stießen die politischen Planvorgaben auf materielle Engpässe und wenig Nachfrage in der Wärmeversorgung. Nach der abrupten Reduzierung der Zielvorgaben für die Wärmepumpenförderung wurde ab 1984 mit besonderem politischem Interesse die Tiefengeothermie gefördert und hierfür der Spezialbetrieb VEB Geothermie Neubrandenburg gegründet. Von den geplanten Anlagen zur Versorgung von Wohngebieten mit insgesamt 110 MW thermischer Leistung konnten bis zum Ende der DDR tiefengeothermische Heizzentralen in Waren, Neubrandenburg und Prenzlau fertiggestellt werden, was 22% der geplanten Leistung entsprach. Somit scheiterte auch das Großprojekt einer geothermischen Wärmeversorgung von Schwerin. Grund waren unter anderem übersteigerte Planvorgaben, der materielle Mangel in der Wirtschaft der DDR und nicht ausreichende Erfahrungen mit der jungen Technologie. / At the end of the 1970s the socialist party of the GDR was forced by high debts in foreign currency and risen import prices for fossil fuels to invest in indigenous energy sources and more rational energy applications. In this context and to take pace with the international development the SED began at the end of the 1970s and during the 1980s to support the use of geothermal heating. This thesis consists of a chronological representation of the geothermal energy support in the GDR and contextualizes East German energy policy, heat supply and use of other renewable energy sources. Historical sources consist to the main extent on archive material and scientific papers from the GDR. Until 1983 the SED tried to promote the application of heat pumps for heat supply. Even though several pilot projects like the heat pump station in Dresden were successfully erected, the political plan targets collided with material short supply and low demand in the heating business. After the sudden reduction of the political targets concerning heat pumps, special political interest was given to geothermal energy in higher depths since 1984. Therefore a special company the VEB Geothermie Neubrandenburg was founded. From the planned stations for heat supply of residential areas with a total power of 110 MW only 22% were actually finished until the end of the GDR in 1990. Those stations were located in Waren, Neubrandenburg and Prenzlau in the northern part of East Germany. Consequently failed the major project of a geothermal heat supply of the city of Schwerin. Reasons were excessive plan targets, the material short supply in the East German economy and a lack of experiences in the young technology.
5

Geothermie: Ansätze zur Nutzung regenerativer Energiequellen in der DDR

Eichkorn, Florian 15 September 2015 (has links)
Ende der 1970er Jahre sah sich die SED in der DDR gezwungen angesichts hoher Auslandsverschuldung und gestiegener Importpreise für fossile Energieträger stärker in heimische Energiequellen und rationellere Energieanwendung zu investieren. In diesem Kontext und um Anschluss an die internationale Entwicklung zu halten wurde Ende der 1970er und in den 1980er Jahren die Nutzung oberflächennaher und tiefer Geothermie gefördert. Im Rahmen dieser Arbeit wird neben einer chronologischen Darstellung der Geothermieförderung in der DDR eine Einordnung in deren Energiepolitik, der Wärmeversorgung und der Förderung anderer erneuerbarer Energien geleistet. Aufgrund des geringen historischen Forschungsstandes zur Geothermie und der Wärmeversorgung in der DDR allgemein wurde dieser Arbeit ein explorativer Ansatz zugrunde gelegt. Als Quellenbasis dienten unter anderem Artikel aus wissenschaftlichen Zeitschriften der DDR und verschiedene Archivbestände. Ende der 1970er Jahre bis 1983 versuchte die SED den Einsatz von Wärmepumpen für die Wärmeversorgung zu fördern. Obwohl zahlreiche Pilotprojekte wie die Wärmepumpenheizzentrale Dresden fertiggestellt wurden stießen die politischen Planvorgaben auf materielle Engpässe und wenig Nachfrage in der Wärmeversorgung. Nach der abrupten Reduzierung der Zielvorgaben für die Wärmepumpenförderung wurde ab 1984 mit besonderem politischem Interesse die Tiefengeothermie gefördert und hierfür der Spezialbetrieb VEB Geothermie Neubrandenburg gegründet. Von den geplanten Anlagen zur Versorgung von Wohngebieten mit insgesamt 110 MW thermischer Leistung konnten bis zum Ende der DDR tiefengeothermische Heizzentralen in Waren, Neubrandenburg und Prenzlau fertiggestellt werden, was 22% der geplanten Leistung entsprach. Somit scheiterte auch das Großprojekt einer geothermischen Wärmeversorgung von Schwerin. Grund waren unter anderem übersteigerte Planvorgaben, der materielle Mangel in der Wirtschaft der DDR und nicht ausreichende Erfahrungen mit der jungen Technologie.:1. Einleitung 3 2. Energiepolitik in der DDR 7 2.1 Energiepolitik der SED 7 2.2 Regenerative Energiequellen in der Energiepolitik 9 3. Erdwärme in der Energiewirtschaft der DDR 13 3.1 Akteure der Energiewirtschaft 13 3.2 Wärmeversorgung 15 3.3 Nutzung regenerativer Energiequellen 18 4. Oberflächennahe und tiefe Geothermie 22 4.2 Wärmepumpen zur Nutzung von Umweltwärme 22 4.2.1 Wärmepumpen für die rationelle Energieanwendung 22 4.2.2 Fallbeispiel Wärmepumpen-Heizzentrale Dresden 28 4.2.3 Vorzeitiges Ende der Wärmepumpenförderung 33 4.3 Tiefengeothermie im Norden der DDR 35 4.3.1 Hohe Erwartungen an die Tiefengeothermie 35 4.3.2 Grenzen der Leistungsfähigkeit des VEB Geothermie 41 5. Zusammenfassung 48 Literatur 51 Archivalische Quellen 54 Abbildungs- und Tabellenverzeichnis 56 Abkürzungsverzeichnis 57 Physikalisch-technischer Anhang 58 / At the end of the 1970s the socialist party of the GDR was forced by high debts in foreign currency and risen import prices for fossil fuels to invest in indigenous energy sources and more rational energy applications. In this context and to take pace with the international development the SED began at the end of the 1970s and during the 1980s to support the use of geothermal heating. This thesis consists of a chronological representation of the geothermal energy support in the GDR and contextualizes East German energy policy, heat supply and use of other renewable energy sources. Historical sources consist to the main extent on archive material and scientific papers from the GDR. Until 1983 the SED tried to promote the application of heat pumps for heat supply. Even though several pilot projects like the heat pump station in Dresden were successfully erected, the political plan targets collided with material short supply and low demand in the heating business. After the sudden reduction of the political targets concerning heat pumps, special political interest was given to geothermal energy in higher depths since 1984. Therefore a special company the VEB Geothermie Neubrandenburg was founded. From the planned stations for heat supply of residential areas with a total power of 110 MW only 22% were actually finished until the end of the GDR in 1990. Those stations were located in Waren, Neubrandenburg and Prenzlau in the northern part of East Germany. Consequently failed the major project of a geothermal heat supply of the city of Schwerin. Reasons were excessive plan targets, the material short supply in the East German economy and a lack of experiences in the young technology.:1. Einleitung 3 2. Energiepolitik in der DDR 7 2.1 Energiepolitik der SED 7 2.2 Regenerative Energiequellen in der Energiepolitik 9 3. Erdwärme in der Energiewirtschaft der DDR 13 3.1 Akteure der Energiewirtschaft 13 3.2 Wärmeversorgung 15 3.3 Nutzung regenerativer Energiequellen 18 4. Oberflächennahe und tiefe Geothermie 22 4.2 Wärmepumpen zur Nutzung von Umweltwärme 22 4.2.1 Wärmepumpen für die rationelle Energieanwendung 22 4.2.2 Fallbeispiel Wärmepumpen-Heizzentrale Dresden 28 4.2.3 Vorzeitiges Ende der Wärmepumpenförderung 33 4.3 Tiefengeothermie im Norden der DDR 35 4.3.1 Hohe Erwartungen an die Tiefengeothermie 35 4.3.2 Grenzen der Leistungsfähigkeit des VEB Geothermie 41 5. Zusammenfassung 48 Literatur 51 Archivalische Quellen 54 Abbildungs- und Tabellenverzeichnis 56 Abkürzungsverzeichnis 57 Physikalisch-technischer Anhang 58