• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 14
  • 14
  • 14
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Evaluation of the Impact of X-ray Tube Voltage and Filter Thickness on the Performance of Spectral Photon-Counting Detectors / Utvärdering av inverkan av röntgenrörsspänning och filtertjocklek på prestanda för spektrala fotonräknande detektorer

Mannila, Cassandra, Larsson, Marcus January 2021 (has links)
During the past years photon-counting detectors (PCDs) have emerged as an alternative to conventional energy-integrating detectors and may significantly improve the standard of care for computed tomography (CT). There are two main alternatives for the material of the detector: cadmium telluride (CdTe) and silicon (Si). The settings of the X-ray tube and the applied filters need to be evaluated and optimized for the new detector technology. In this report, Monte Carlo simulations are used to determine how image quality is affected by different X-ray tube voltages and filter thicknesses. The image quality indicators that were chosen to evaluate are detective quantum efficiency (DQE) for material quantification and both DQE and dose-normalized signal-difference-to-noise ratio (SDNR) for detection tasks. Overall, silicon-based detectors performed better than cadmium-based detectors for quantification imaging tasks for all object thicknesses, while cadmium-based detectors were superior for detection imaging tasks in larger patients. For both silicon- and cadmium-based detectors, the dose-normalized image quality was largely independent of filter thickness, while the X-ray tube voltage had a more distinct impact on the result, where low voltages were optimal. / Under de senaste åren har fotonräknande detektorer blivit aktuellt som ett alternativ till konventionella energiintegrerande detektorer och kommer troligen förbättra datortomografibilder avsevärt. För de nya detektorerna finns det två huvudsakliga materialalternativ: kadmiumtellurid (CdTe) och kisel (Si). Inställningarna för röntgenröret och det pålagda filtret behöver utvärderas och optimeras för den nya detektorteknologin. I denna rapport användes Monte Carlo-simuleringar för att bestämma hur bildkvaliteten påverkades av rörspänningen och filtertjockleken. Bildkvaliteten bestämdes sedan utifrån tre indikatorer, detective quantum efficiency (DQE) för materialbestämning samt både DQE och dosnormaliserad signal-difference-to-noise ratio (SDNR) för detektionsuppgifter.    Den kiselbaserade detektorn presterade bättre än den kadmiumbaserade för materialbestämning för alla patientstorlekar medan den kadmiumbaserade presterade bättre på detektionsuppgifterna för större patienter. Vidare var den dosnormaliserade bildkvaliteten för både kisel- och kadmiumdetektorer svagt beroende av filtertjocklek medan båda påverkades starkt av rörspänningen, där låga spänningar var att föredra.
12

Kirkpatrick-Baez Microscope for Hard X-Ray Imaging of Fast Ignition Experiments

Friesen, Hal Unknown Date
No description available.
13

Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe

Rahn, Helene 13 February 2012 (has links) (PDF)
Im Rahmen der vorliegenden Dissertationsschrift „Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe“ wurden tomographische Untersuchungen an biologischen Objekten durchgeführt. Bei diesen Objekten handelt es sich um Gewebeproben nach minimal-invasiven Krebstherapien wie zum Beispiel magnetischem Drug Targeting und magnetischer Wärmebehandlung. Der Erfolg dieser Therapien ist sowohl abhängig von der korrekten Verteilung der magnetischen Nanopartikel als auch von der Tatsache, dass diese in der Zielregion in einer ausreichenden Menge vorhanden sind. Das Vorliegen dieser beiden Voraussetzungen ist in der vorliegenden Arbeit untersucht worden. Dabei lag der Schwerpunkt der Arbeit auf der Quantifizierung von magnetischem Material in unterschiedlichen biologischen Gewebeproben mittels Röntgenmikrocomputertomographie (XµCT). Für diesen Zweck wurde ein Kalibrationssystem mit speziellen Phantomen entwickelt, mit dessen Hilfe eine Nanopartikelkonzentration einem Grauwert voxelweise zugewiesen werden kann. Mit Hilfe der Kalibration kann der Nanopartikelgehalt sowohl in monochromatischen als auch in polychromatischen tomographischen Daten im Vergleich zu magnetorelaxometrischen Ergebnissen mit wenigen Prozent Abweichung ermittelt werden. Trotz Polychromasie und damit einhergehenden Artefakten können 3-dimensionale röntgentomographische Datensätze mit einer geringfügigen Konzentrationsabweichung im Vergleich zur quantitativen Messmethode Magnetorelaxometrie semi-quantitativ ausgewertet werden. / The success of the minimal invasive cancer therapies, called magnetic drug targeting and magnetic heating treatment, depends strongly on the correct distribution of the magnetic nanoparticles on one side. On the other side it depends on the fact that a sufficient amount of magnetic nanoparticles carrying drugs is accumulated in the target region. To study whether these two requirements are fulfilled motivates this PhD thesis „Semi-quantitative X-ray-tomography examinations of biodistribution of magnetic nanoparticles in biological tissues“. The analysis of the distribution of the magnetic nanoparticles in tumours and other tissue examples is realized by means of X-ray-micro computer tomography (XμCT). The work focuses on the quantification of the magnetic nanoparticles in different biological tissue samples by means of XµCT. A calibration of the tomographic devices with adequate phantoms, developed in the frame of this work, opens now the possibility to analyze tomographic data in a semi-quantitative manner. Thus, the nanoparticle concentration can be allocated voxel-wise to the grey values of the three-dimensional tomographic data. With the help of calibration of the tomography equipments used, polychromatic as well as monochromatic three-dimensional representations of objects can be analyzed with regard to the biodistribution of magnetic nanoparticles as well as with regard to their quantity. The semi-quantitative results have been compared with results obtained with a quantitative measurement method magnetorelaxometry (MRX). Thereby a good agreement of the semi-quantitative and quantitative data has been figured out.
14

Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe

Rahn, Helene 12 December 2011 (has links)
Im Rahmen der vorliegenden Dissertationsschrift „Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe“ wurden tomographische Untersuchungen an biologischen Objekten durchgeführt. Bei diesen Objekten handelt es sich um Gewebeproben nach minimal-invasiven Krebstherapien wie zum Beispiel magnetischem Drug Targeting und magnetischer Wärmebehandlung. Der Erfolg dieser Therapien ist sowohl abhängig von der korrekten Verteilung der magnetischen Nanopartikel als auch von der Tatsache, dass diese in der Zielregion in einer ausreichenden Menge vorhanden sind. Das Vorliegen dieser beiden Voraussetzungen ist in der vorliegenden Arbeit untersucht worden. Dabei lag der Schwerpunkt der Arbeit auf der Quantifizierung von magnetischem Material in unterschiedlichen biologischen Gewebeproben mittels Röntgenmikrocomputertomographie (XµCT). Für diesen Zweck wurde ein Kalibrationssystem mit speziellen Phantomen entwickelt, mit dessen Hilfe eine Nanopartikelkonzentration einem Grauwert voxelweise zugewiesen werden kann. Mit Hilfe der Kalibration kann der Nanopartikelgehalt sowohl in monochromatischen als auch in polychromatischen tomographischen Daten im Vergleich zu magnetorelaxometrischen Ergebnissen mit wenigen Prozent Abweichung ermittelt werden. Trotz Polychromasie und damit einhergehenden Artefakten können 3-dimensionale röntgentomographische Datensätze mit einer geringfügigen Konzentrationsabweichung im Vergleich zur quantitativen Messmethode Magnetorelaxometrie semi-quantitativ ausgewertet werden. / The success of the minimal invasive cancer therapies, called magnetic drug targeting and magnetic heating treatment, depends strongly on the correct distribution of the magnetic nanoparticles on one side. On the other side it depends on the fact that a sufficient amount of magnetic nanoparticles carrying drugs is accumulated in the target region. To study whether these two requirements are fulfilled motivates this PhD thesis „Semi-quantitative X-ray-tomography examinations of biodistribution of magnetic nanoparticles in biological tissues“. The analysis of the distribution of the magnetic nanoparticles in tumours and other tissue examples is realized by means of X-ray-micro computer tomography (XμCT). The work focuses on the quantification of the magnetic nanoparticles in different biological tissue samples by means of XµCT. A calibration of the tomographic devices with adequate phantoms, developed in the frame of this work, opens now the possibility to analyze tomographic data in a semi-quantitative manner. Thus, the nanoparticle concentration can be allocated voxel-wise to the grey values of the three-dimensional tomographic data. With the help of calibration of the tomography equipments used, polychromatic as well as monochromatic three-dimensional representations of objects can be analyzed with regard to the biodistribution of magnetic nanoparticles as well as with regard to their quantity. The semi-quantitative results have been compared with results obtained with a quantitative measurement method magnetorelaxometry (MRX). Thereby a good agreement of the semi-quantitative and quantitative data has been figured out.

Page generated in 0.0725 seconds