• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 2
  • Tagged with
  • 26
  • 22
  • 11
  • 10
  • 9
  • 9
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação de parâmetros ergonômicos: vibração e ruído em roçadoras laterais / Ergonomic parameters evaluation: vibration and noise on lateral brushcutters

Schutzer, Victor Manieri 23 February 2018 (has links)
Submitted by Victor Manieri Schutzer null (victor_schutzer@hotmail.com) on 2018-04-05T01:19:20Z No. of bitstreams: 1 Dissertação completa - victor manieri schutzer.pdf: 2057859 bytes, checksum: 965ab65ab6bb0942e2639d8fdfbafe05 (MD5) / Approved for entry into archive by Lucilene Cordeiro da Silva Messias null (lubiblio@bauru.unesp.br) on 2018-04-05T12:41:58Z (GMT) No. of bitstreams: 1 schutzer_vm_me_bauru.pdf: 2057859 bytes, checksum: 965ab65ab6bb0942e2639d8fdfbafe05 (MD5) / Made available in DSpace on 2018-04-05T12:41:58Z (GMT). No. of bitstreams: 1 schutzer_vm_me_bauru.pdf: 2057859 bytes, checksum: 965ab65ab6bb0942e2639d8fdfbafe05 (MD5) Previous issue date: 2018-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A crescente mecanização na agricultura mundial foi acompanhada do aumento do número de acidentes e fez com que elevasse a preocupação com a saúde de seus operadores, já que tais trabalhadores estão expostos aos riscos que esse tipo de atividade proporciona. Alguns dos graves problemas que são gerados pelos equipamentos agrícolas é a alta vibração e ruído a que os operadores ficam expostos na sua jornada de trabalho. A vibração que atinge os trabalhadores pode ser considerada como um distúrbio, já que é responsável por grandes prejuízos à saúde do ser humano, estando diretamente relacionada com a fadiga do trabalhador. O ruído, considerado como um som indesejável, é outro problema gerado por máquinas motoras e responsável por lesão no aparelho auditivo e, até mesmo, por estresse psicofisiológico. Para o presente trabalho, analisou-se os riscos físicos que a vibração e o ruído causam em operadores de roçadoras motorizadas. Foram feitas análises de situações reais que os usuários deste tipo de máquina enfrentam no seu dia a dia de trabalho, para que se possa tirar conclusões da possibilidade de efeitos danosos. Para a pesquisa utilizou-se um acelerômetro de três eixos - HVM 100, marca Larson Davis, para mensurar a vibração captada pela mão do operador e um medidor de pressão sonora, marca Instrutherm, modelo DEC-460 para mensurar o ruído causado pela roçadora. Para a análise da vibração captada pela mão dos operadores foi utilizada a norma internacional ISO 5349 (2001) – Vibração Mecânica – Medição, Avaliação da Exposição Humana da Vibração Transmitida à Mão e Diretiva Europeia 2002/44/EC que estabelece os limites de exposição à vibração. As análises do ruído foram feitas a partir da Norma Regulamentadora – NR-15 – Atividades e Operações Insalubres. Os resultados de vibração e ruído apresentados em alguns testes ficaram acima do que estabelece a norma para que não haja prejuízo à saúde dos operadores deste tipo de equipamento durante uma exposição equivalente a uma jornada de trabalho de 8 horas. Além disso, mostra a importância do estudo, escolha e, principalmente, da correta utilização de EPI (Equipamento de Proteção Individual) para que minimize a vibração e o ruído que chegam ao organismo humano. É importante, ainda, a manutenção periódica dos equipamentos mecânicos para que os mesmos funcionem corretamente, evitando quebras das máquinas e danos aos operadores de tais equipamentos. / The increasing mechanization in world agriculture was accompanied by an increase in the number of accidents has caused concern about the health of its operators, as these workers are exposed to risks that this type of activity provides. Some of the serious problems that are generated by agricultural equipment are the high vibration and noise to which operators are exposed in their work. The vibration that affects the workers can be considered as a disorder, since it is responsible for major damages to the health of human beings, being directly related to worker fatigue. Noise, regarded as an unwanted sound, is another problem caused by motorized machines and responsible to hearing damage and even to psychophysiological stress. For this study, a physical risks analysis was made. So it is possible to determine the damage that vibration and noise can cause in motorized brushcutter’s operators. Real situations of the daily work that these users go through were analyzed, so that conclusions can be made of the possibility of harmful effects. For the research, an accelerometer of three axes - HVM 100, Larson Davis brand, was used to measure the vibration captured by the hand of the operator and a sound pressure meter, Instrutherm brand model DEC-460, was used to measure the noise caused by brushcutters. For the vibration analysis captured by the hand of the operators, the international standard ISO 5349 (2001) - Mechanical Vibration - Measurement and Evaluation of Human Exposure to Hand-Transmitted Vibration and the European Directive 2002/44/EC establishing the exposure limits for vibrations were used. Noise analysis was made based on the Regulatory Standard - NR-15 - Unhealthy Activities and Operations. The noise and vibration results in some tests were above the standard so that there is no damage to the health of the operators of such equipment during an exposure equivalent to an 8 hours working day. This also shows the importance of the study, choice and especially the proper use of PPE (Personal Protective Equipment) to minimize vibration and noise coming to the human body. The regular maintenance of mechanical equipment is also important so that they function properly, avoiding machinery breakages and damage to operators of such equipment.
12

Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico

Loterio, Flávia Aparecida 20 February 2015 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2015-08-05T19:51:10Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico.pdf: 3323589 bytes, checksum: 66acf0b992631a97d58c6a48254bba01 (MD5) / Approved for entry into archive by Elizabete Silva (elizabete.silva@ufes.br) on 2015-08-14T21:06:31Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico.pdf: 3323589 bytes, checksum: 66acf0b992631a97d58c6a48254bba01 (MD5) / Made available in DSpace on 2015-08-14T21:06:31Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico.pdf: 3323589 bytes, checksum: 66acf0b992631a97d58c6a48254bba01 (MD5) Previous issue date: 2015 / O Acidente Vascular Cerebral (AVC) é uma das principais causas de prejuízos ao sistema neuromuscular. Dispositivos Robóticos vêm sendo amplamente desenvolvidos e estudados com a finalidade de serem utilizados na assistência à marcha e para o treinamento da marcha durante a reabilitação. O objetivo deste trabalho é avaliar a marcha assistida pelo AROW (Assistive Robotic Walker) em indivíduos hemiparéticos pós-AVC, através da análise de sinais de acelerometria e sinais mioelétricos de superfície (sEMG) provenientes dos músculos vasto medial (VM), bíceps femoral (BF), tibial anterior (TA) e gastrocnêmio medial (GM), e também utilizando os métodos de avaliação GAS (Goal Attainment Scaling) e SUS (System Usability Scale). Nove indivíduos hemiparéticos participaram dos testes. A velocidade da marcha foi reduzida com o uso do AROW e, consequentemente, houve algumas alterações na duração das fases da marcha, por exemplo, uma maior duração da fase de apoio (p = 0,0174). O padrão de ativação muscular para o grupo analisado não apresentou diferença estatisticamente significativa (início da ativação VM: p= 0,4999; término da ativação VM: p= 0,5647; início BF: p= 0,1186; término BF: p= 0,7823; início TA: p= 0,5833; término TA: p= 0,8393; início GM: p= 0,6077; término GM: p= 0,1429). Entretanto, avaliando o padrão de ativação muscular individualmente, podem-se notar algumas alterações benéficas, por exemplo, redução da coativação dos músculos tibial anterior e gastrocnêmio medial. Os resultados das avaliações através do GAS (54,8) e SUS (81,4) sobre o uso do AROW mostraram boa aceitação pelos usuários, e os objetivos esperados durante o uso do andador foram atingidos. A adaptação rápida, facilidade de utilização e sentimento de segurança ao usar o dispositivo são pontos positivos obtidos com o uso do AROW. / Stroke is a leading cause of damages in the neuromuscular system. Robotic devices have been widely developed and studied in order to be used in gait assistance and gait training during the rehabilitation. The goal of this work is to evaluate the assisted gait by the AROW (Assistive Robotic Walker) in post stroke hemiparetic individuals through accelerometer signals and surface Electromyography (sEMG) analysis. The analyzed muscles are vastus medialis (VM), biceps femoris (BF), tibialis anterior (TA) and gastrocnemius medialis (GM). Furthermore, the evaluation methods GAS (Goal Attainment Scaling) and SUS (System Usability Scale) were used. Nine hemiparetic subjects participate of the experiments. The gait speed was decreased using the walker and, consequently, there were some changes in the duration of gait phases, for instance longer of support phase (p = 0.0174). The muscle activation pattern for the analyzed group did not show statistically significant difference (onset VM: p= 0.4999; offset VM: p= 0.5647; onset BF: p= 0.1186; offset BF: p= 0.7823; onset TA: p= 0.5833; offset TA: p= 0.8393; onset GM: p= 0.6077; offset GM: p= 0.1429).. However, assessing the muscle activation pattern individually, some benefic changes can be noted, for example, the reduced co-activation between tibialis anterior and gastrocnemius medial. The results of evaluations through GAS (54.8) and SUS (81.4) about the use of the AROW showed good acceptance among users, and the desired results during the use of the walker were achieved. The fast adaptation, easiness of use and feeling of safety when using the device are positive points that were obtained using the AROW.
13

Avaliação da vibração mecânica com o uso de aparelhos de massagem vibratórios comerciais / Evaluation of mechanical vibration with the use of vibratin massage equipment business

Leonardo Serafim dos Santos 12 December 2009 (has links)
A massagem tradicional tem sido auxiliada com o uso de acessórios convencionais e eletro-eletrônicos, onde estes produtos trabalham por intermédio de equipamentos programados por micro-controladores que atuam de forma eficiente, atuando na qualidade de vida do ser humano. O objetivo principal deste trabalho foi comparar os níveis de freqüência (Hz) da almofada vibratória com os da esteira vibratória tendo como referência a massagem tradicional e a vibroterapia, analisando por meio de pesquisa quantitativa o desenvolvimento e fabricação de aparelhos vibratórios. Não é do nosso conhecimento estudos avaliando tais parâmetros nesta área, pois a comparação e detalhamento de freqüências tem o parecer inédito neste aspecto. Foram feitos dez medições de freqüências com uso de tacômetro e acelerômetro para as quatro funções na almofada vibratória e, cinco medições para as quinze funções na esteira vibratória onde os valores de intensidades mínimo e máximo foram comparados às normas para garantir o bem estar no momento da utilização. Para os aparelhos vibratórios utilizados nesse trabalho, foram encontrados valores de freqüências de 7,33 a 116,35 Hz, onde na massagem tradicional a variação é de 10 a 20 Hz, para as normas de fabricação é de 1 a 100 Hz para corpo inteiro, 5 a 1.250 Hz para as transmitidas à mão e 100 a 300 Hz citados em trabalhos acadêmicos. Portanto, ambos os aparelhos vibratórios apresentaram resultados de valores de freqüência dentro dos limites definidos pelos autores de trabalhos acadêmicos, assim como as normas de fabricação. / The traditional massage has been assisted with use of conventional accessories and electric-electronics, where this product works for intermediary of equipment programmed by microcontrollers that act of efficient form acting in the quality of life of the human being. The mean goal of this study was to compare the levels of frequency (Hz) vibration of the pad with the belt vibration with reference to traditional massage and vibrotherapy, analyzing by quantitative research development and manufacturing of vibration equipments. Not the best of our knowledge studies evaluating these parameters in this area, because the comparison of frequencies and detail has unpublished opinion in this regard. Ten measurements were made of frequencies using tachometer and accelerometer for the four functions in vibrating cushion and, five measurements for the fifteen functions in vibrating mat where the values of minimum and maximum of intensities were compared to standards to ensure the well-being at use. For the vibration equipments used in this study, we found values of frequencies from 7,33 to 116,35 Hz, where the change in traditional massage is 10 to 20 Hz, for the standards of manufacture is from 1 to 100 Hz for the whole body , 5 to 1.250 Hz vibration to the hands and 100 Hz to 300 cited in academic work. Therefore, both devices performed vibration frequency of values within the limits defined by the authors of academic works and the manufacture standards.
14

Avaliação do nível de atividade física de pacientes com doença renal crônica em hemodiálise

Gomes, Edimar Pedrosa 02 August 2013 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-05-18T12:35:08Z No. of bitstreams: 1 edimarpedrosagomes.pdf: 940108 bytes, checksum: 884d94d7277860ef98661b0483d9d892 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-05-18T12:50:06Z (GMT) No. of bitstreams: 1 edimarpedrosagomes.pdf: 940108 bytes, checksum: 884d94d7277860ef98661b0483d9d892 (MD5) / Made available in DSpace on 2017-05-18T12:50:06Z (GMT). No. of bitstreams: 1 edimarpedrosagomes.pdf: 940108 bytes, checksum: 884d94d7277860ef98661b0483d9d892 (MD5) Previous issue date: 2013-08-02 / Introdução: Inatividade física é a quarta principal causa de morte em todo o mundo, principalmente devido à sua associação com as doenças cardiovasculares, que são particularmente importantes nos pacientes em hemodiálise. Objetivos: Este estudo investigou a atividade física na vida diária de pacientes em hemodiálise, usando um acelerômetro triaxial e avaliou as variáveis fisiológicas associadas à inatividade. Métodos: 19 pacientes em hemodiálise (47,5+12,5 anos) foram avaliados e comparados com 19 controles sedentários (45,9+13,3 anos), em relação ao tempo gasto em diferentes atividades ou posições (andando, de pé, sentado ou deitado) e ao número de passos dados. Resultados: Os pacientes em hemodiálise apresentaram menor tempo ativo (soma dos períodos andando e de pé) por dia do que o grupo controle (193,0+54,0 vs. 272,0+78,8 minutos/dia; p=0,001), com menor tempo de caminhada (70,1+27,3 vs. 100,7+32,6 minutos/dia; p=0,003) e menor tempo em pé (122,8+40,4 vs. 171,2+65,3 minutos/dia; p=0,009). Os pacientes em hemodiálise também permaneceram mais tempo deitados do que os controles (201,1+93,2 vs. 46,6+68,8 minutos/dia; p<0,001). De acordo com o número de passos dados por dia, 47,4% dos pacientes em hemodiálise foram considerados sedentários, contra 10,5% no grupo controle. Pacientes em hemodiálise permaneceram mais sedentários nos dias com diálise. O nível de hemoglobina correlacionou com o tempo gasto caminhando (r=0,53, p=0,003). Conclusões: Os pacientes em hemodiálise são menos ativos que os indivíduos sem doença renal crônica, principalmente nos dias com diálise. Entre as variáveis estudadas, apenas a hemoglobina correlacionou-se com a inatividade física. / Introduction: Physical inactivity is the fourth leading cause of death worldwide, mainly by its association with cardiovascular diseases, especially in hemodialysis patients. This study investigated the physical activity in daily life in hemodialysis patients, by using a triaxial accelerometer and evaluated the physiological variables associated with inactivity. A total of 19 hemodialysis patients (47.5 + 12.5 years) were evaluated and compared with 19 control individuals (45.9 + 13.3 years), regarding the time spent in different activities and positions of daily life (walking, standing, sitting and lying), and the number of steps taken. Results: The hemodialysis patients demonstrated a shorter activity time (walking plus standing time) per day than control subjects (193.0 + 54.0 vs. 272.0 + 78.8 min/day; p=0.001), with shorter walking (70.1 + 27.3 vs. 100.7 + 32.6 min/day; p=0.003) and standing time (122.8 + 40.4 vs. 171.2 + 65.3 min/day; p=0.009). Hemodialysis patients spent more time lying down per day than control subjects (201.1 + 93.2 vs. 46.6 + 68.8 min/day; p<0.001). According the number of steps taken per day, 47.4% of hemodialysis patients were classified as sedentary against 10.5% in control group. Hemodialysis patients were more sedentary on dialysis days than on non-dialysis days. The hemoglobin level correlated with the walking time (r=0.53, p=0.003). Conclusions: Hemodialysis patients are less active than individuals without chronic kidney disease, especially on dialysis days. Among the variables studied, only hemoglobin correlated with physical inactivity.
15

Intensidade e duração dos esforços físicos em aulas de Educação Física curriculares / Intensity and duration of physical efforts in physical education classes.

Kremer, Marina Marques 26 February 2010 (has links)
Made available in DSpace on 2014-08-20T13:49:17Z (GMT). No. of bitstreams: 1 Marina Kremer.pdf: 2292543 bytes, checksum: 3a2779d82461fca54a905419fba65fb2 (MD5) Previous issue date: 2010-02-26 / The school, and in particular the Physical Education classes (PE), are in a privileged position for the promotion of health among children and adolescents. However, little is known about the PE programs in Brazil. The aim of this study was to estimate the intensity and duration of physical efforts in PE classes in primary and secondary school. Methodology: A school-based cross-sectional study was carried out. A multistage sampling strategy was used, including stratification by education network (public and private) and grade. We sampled 16 schools, and 272 students took part in the study, totaling 218 classes observations. We administered a questionnaire to identify physical spaces and materials available to the PE classes and a questionnaire for students. The outcome variables were evaluated by an instrument of direct observation the System for Observing Fitness Instruction Time SOFIT; and the intensity of the classes was measured by accelerometry. To determine the intensity of the efforts we used the following cut-off points (in counts): sedentary activities (0-100), light activities (101-2000), moderate activities (2001-4999), vigorous (5000-7999) and very vigorous (>8000). The outcome "moderate to vigorous physical activity (MVPA)" was created by grouping moderate, vigorous and very vigorous activities. Results: The mean duration of the classes was 35.6 minutes (SD 6.0), whereas the mean time spent in MVPA was 12.3 minutes (SD 9.7). The mean proportion of the time spent on MVPA was 32.7% (SD 25.2). Boys (44.1%) spent a higher proportion of the classes in MVPA as compared to girls (21.0%; p<0.01). Students who practice physical activity outside the PE classes were more likely to engage in MVPA during the classes. There were no significant differences in the practice of MVPA in different educational networks and school grades. Conclusions: The proportion of time spent in MVPA was low, indicating that during PE classes students are, most of the time, carrying out activities that are not of sufficient intensity and duration to produce organic changes leading to health benefits. Urgent strategies are needed in order to increase the intensity and duration of physical efforts in Physical Education classes / A escola, em especial as aulas de Educação Física (EF) encontram-se em posição privilegiada para promoção da saúde entre crianças e adolescentes. Entretanto, pouco se conhece sobre os programas de EF no Brasil. O objetivo do estudo foi determinar a intensidade e duração dos esforços físicos nas aulas de EF no ensino fundamental e médio. Metodologia: Foi desenvolvido um estudo transversal de base escolar. A amostragem foi realizada em múltiplos estágios, estratificada por rede, nível e série de ensino. Ao todo, 16 escolas e 272 estudantes participaram do estudo, totalizando 218 observações de aula. Foi aplicado um questionário para identificar espaços físicos e materiais disponíveis para a aula de EF e um questionário para os estudantes. As aulas foram avaliadas através do instrumento de observação direta SOFIT (System for Observing Fitness Instruction Time) e a intensidade mensurada através de acelerômetros. Para a determinação da intensidade dos esforços foram adotados os seguintes pontos de corte (em counts): atividades sedentárias (0-100), leves (101-2000), moderadas (2001-4999), vigorosas (5000-7999) e muito vigorosas (>8000). Para determinação do desfecho atividades físicas moderadas a vigorosas (AFMV) foram agrupadas as categorias de AF moderada, vigorosa e muito vigorosa. Resultados: O tempo médio de duração das aulas foi de 35,6 minutos (DP 6,0), enquanto que a média de tempo das aulas despendido efetivamente em AFMV foi de 12,3 minutos (DP 9,7). A proporção média de tempo das aulas em AFMV foi de 32, 7% (DP 25,2). Os meninos (44,1%) envolveram-se significativamente mais em AFMV do que as meninas (21,0%; p<0,01). Estudantes que se envolvem em atividade física fora das aulas também tiveram maior participação em AFMV nas aulas de EF. Não foram encontradas diferenças significativas na prática de AFMV em diferentes redes de ensino e série escolar. Conclusão: A proporção de tempo em AFMV encontrada foi baixa indicando que durante as aulas de EF os estudantes são pouco submetidos a atividades com intensidades e duração suficientes para provocar adaptações orgânicas que tragam benefício à saúde. Estratégias urgentes são necessárias para o aumento da intensidade e duração dos esforços físicos em aulas de Educação Física.
16

Abstração de eventos de sensores para dispositivos de interação / Abstraction of sensor events for interaction devices

Santos, Felipe Silva 26 May 2008 (has links)
Vários tipos de sensores têm sido explorados na construção de mecanismos para capturar, por exemplo, movimentos dos olhos, da cabeça, ou do tórax do usuário. A construção de dispositivos de interação baseados em tais sensores demandam conhecimentos especializados. O trabalho aqui reportado teve como objetivo desenvolver uma arquitetura de componentes de hardware e software que fornece, como dados de entrada para aplicações computacionais, eventos capturados de sensores tais como os que detectam inclinação, rotação e aceleração. A pesquisa envolveu a concepção e a implementação de uma arquitetura em camadas que possui, em sua base, uma camada de hardware composta por um conjunto de sensores e circuitos apropriados que mensuram eventos físicos e, nas demais camadas, componentes de software que permitem associar uma semântica de dados de entrada para aplicações aos dados primitivos provenientes dos sensores e das camadas intermediárias. Como resultado, a arquitetura disponibiliza os dados dos sensores como eventos em alto nível, que podem ser associados a operações de interação usuário-computador típicas de um mouse, de um teclado ou de um joystick, por exemplo. A implementação de um dispositivo de interação baseado em sensores é facilitada, por um lado, pelo fato de o tratamento de erros associado ao uso de sensores poder ter sido realizado nas camadas inferiores e, por outro, pelo fato de os dados serem apresentados em um alto nível de abstração que não exige conhecimento específico sobre o uso do hardware associado. Como estudo de caso, criouse um dispositivo de interação que permite interações típicas de um mouse, e que pode ser usado por usuários tetraplégicos, que possuam controle fino dos movimentos da cabeça e ausência de deficiências visuais / Some types of sensors have been explored in the construction of mechanisms to capture, for example, movements of the eyes, the head, or the thorax of the user. The construction of devices of interaction based in such sensors demand specialized knowledge. The work reported here had as objective to develop an architecture of components of the hardware and software that it supplies, as given of entrance for computational applications, captured events of sensors such as the ones that detect inclination, rotation and acceleration. The research involved the conception and the implementation of a in layers architecture that it possesss, in its base, a composed layer of the hardware for a set of sensors and appropriate circuits that measure physical events and, in the too much layers, software components that allow to associate a semantics of data of entrance for applications to the primitive data proceeding from the sensors and the intermediate layers. As result, the architecture makes available the data of the sensors as events in high level, that can be associates the operations of typical interaction one user-computer mouse, of a keyboard or one joystick, for example. The implementation of a device of interaction based on sensors is facilitated, on the other hand, for the fact of the treatment of errors associated to the use of sensors to be able to have been carried through in inferior layers e, for another one, the fact of the data to be presented in one high level of abstraction that does not demand specific knowledge on the use of the associated hardware. As case study, an interaction device was created that allows typical interactions of one mouse, and that it can be used for tetraplegic users, who possess fine control of the movements of the head and absence of visual deficiencies
17

Abstração de eventos de sensores para dispositivos de interação / Abstraction of sensor events for interaction devices

Felipe Silva Santos 26 May 2008 (has links)
Vários tipos de sensores têm sido explorados na construção de mecanismos para capturar, por exemplo, movimentos dos olhos, da cabeça, ou do tórax do usuário. A construção de dispositivos de interação baseados em tais sensores demandam conhecimentos especializados. O trabalho aqui reportado teve como objetivo desenvolver uma arquitetura de componentes de hardware e software que fornece, como dados de entrada para aplicações computacionais, eventos capturados de sensores tais como os que detectam inclinação, rotação e aceleração. A pesquisa envolveu a concepção e a implementação de uma arquitetura em camadas que possui, em sua base, uma camada de hardware composta por um conjunto de sensores e circuitos apropriados que mensuram eventos físicos e, nas demais camadas, componentes de software que permitem associar uma semântica de dados de entrada para aplicações aos dados primitivos provenientes dos sensores e das camadas intermediárias. Como resultado, a arquitetura disponibiliza os dados dos sensores como eventos em alto nível, que podem ser associados a operações de interação usuário-computador típicas de um mouse, de um teclado ou de um joystick, por exemplo. A implementação de um dispositivo de interação baseado em sensores é facilitada, por um lado, pelo fato de o tratamento de erros associado ao uso de sensores poder ter sido realizado nas camadas inferiores e, por outro, pelo fato de os dados serem apresentados em um alto nível de abstração que não exige conhecimento específico sobre o uso do hardware associado. Como estudo de caso, criouse um dispositivo de interação que permite interações típicas de um mouse, e que pode ser usado por usuários tetraplégicos, que possuam controle fino dos movimentos da cabeça e ausência de deficiências visuais / Some types of sensors have been explored in the construction of mechanisms to capture, for example, movements of the eyes, the head, or the thorax of the user. The construction of devices of interaction based in such sensors demand specialized knowledge. The work reported here had as objective to develop an architecture of components of the hardware and software that it supplies, as given of entrance for computational applications, captured events of sensors such as the ones that detect inclination, rotation and acceleration. The research involved the conception and the implementation of a in layers architecture that it possesss, in its base, a composed layer of the hardware for a set of sensors and appropriate circuits that measure physical events and, in the too much layers, software components that allow to associate a semantics of data of entrance for applications to the primitive data proceeding from the sensors and the intermediate layers. As result, the architecture makes available the data of the sensors as events in high level, that can be associates the operations of typical interaction one user-computer mouse, of a keyboard or one joystick, for example. The implementation of a device of interaction based on sensors is facilitated, on the other hand, for the fact of the treatment of errors associated to the use of sensors to be able to have been carried through in inferior layers e, for another one, the fact of the data to be presented in one high level of abstraction that does not demand specific knowledge on the use of the associated hardware. As case study, an interaction device was created that allows typical interactions of one mouse, and that it can be used for tetraplegic users, who possess fine control of the movements of the head and absence of visual deficiencies
18

Biometrics in a data stream context / Biometria em um contexto de fluxo de dados

Pisani, Paulo Henrique 10 March 2017 (has links)
The growing presence of the Internet in day-to-day tasks, along with the evolution of computational systems, contributed to increase data exposure. This scenario highlights the need for safer user authentication systems. An alternative to deal with this is by the use of biometric systems. However, biometric features may change over time, an issue that can affect the recognition performance due to an outdated biometric reference. This effect can be called as template ageing in the area of biometrics and as concept drift in machine learning. It raises the need to automatically adapt the biometric reference over time, a task performed by adaptive biometric systems. This thesis studied adaptive biometric systems considering biometrics in a data stream context. In this context, the test is performed on a biometric data stream, in which the query samples are presented one after another to the biometric system. An adaptive biometric system then has to classify each query and adapt the biometric reference. The decision to perform the adaptation is taken by the biometric system. Among the biometric modalities, this thesis focused on behavioural biometrics, particularly on keystroke dynamics and on accelerometer biometrics. Behavioural modalities tend to be subject to faster changes over time than physical modalities. Nevertheless, there were few studies dealing with adaptive biometric systems for behavioural modalities, highlighting a gap to be explored. Throughout the thesis, several aspects to enhance the design of adaptive biometric systems for behavioural modalities in a data stream context were discussed: proposal of adaptation strategies for the immune-based classification algorithm Self-Detector, combination of genuine and impostor models in the Enhanced Template Update framework and application of score normalization to adaptive biometric systems. Based on the investigation of these aspects, it was observed that the best choice for each studied aspect of the adaptive biometric systems can be different depending on the dataset and, furthermore, depending on the users in the dataset. The different user characteristics, including the way that the biometric features change over time, suggests that adaptation strategies should be chosen per user. This motivated the proposal of a modular adaptive biometric system, named ModBioS, which can choose each of these aspects per user. ModBioS is capable of generalizing several baselines and proposals into a single modular framework, along with the possibility of assigning different adaptation strategies per user. Experimental results showed that the modular adaptive biometric system can outperform several baseline systems, while opening a number of new opportunities for future work. / A crescente presença da Internet nas tarefas do dia a dia, juntamente com a evolução dos sistemas computacionais, contribuiu para aumentar a exposição dos dados. Esse cenário evidencia a necessidade de sistemas de autenticação de usuários mais seguros. Uma alternativa para lidar com isso é pelo uso de sistemas biométricos. Contudo, características biométricas podem mudar com o tempo, o que pode afetar o desempenho de reconhecimento devido a uma referência biométrica desatualizada. Esse efeito pode ser chamado de template ageing na área de sistemas biométricos adaptativos ou de mudança de conceito em aprendizado de máquina. Isso levanta a necessidade de adaptar automaticamente a referência biométrica com o tempo, uma tarefa executada por sistemas biométricos adaptativos. Esta tese estudou sistemas biométricos adaptativos considerando biometria em um contexto de fluxo de dados. Neste contexto, o teste é executado em um fluxo de dados biométrico, em que as amostras de consulta são apresentadas uma após a outra para o sistema biométrico. Um sistema biométrico adaptativo deve então classificar cada consulta e adaptar a referência biométrica. A decisão de executar a adaptação é tomada pelo sistema biométrico. Dentre as modalidades biométricas, esta tese foca em biometria comportamental, em particular em dinâmica da digitação e em biometria por acelerômetro. Modalidades comportamentais tendem a ser sujeitas a mudanças mais rápidas do que modalidades físicas. Entretanto, havia poucos estudos lidando com sistemas biométricos adaptativos para modalidades comportamentais, destacando uma lacuna para ser explorada. Ao longo da tese, diversos aspectos para aprimorar o projeto de sistemas biométricos adaptativos para modalidades comportamentais em um contexto de fluxo de dados foram discutidos: proposta de estratégias de adaptação para o algoritmo de classificação imunológico Self-Detector, combinação de modelos genuíno e impostor no framework do Enhanced Template Update e aplicação de normalização de scores em sistemas biométricos adaptativos. Com base na investigação desses aspectos, foi observado que a melhor escolha para cada aspecto estudado dos sistemas biométricos adaptativos pode ser diferente dependendo do conjunto de dados e, além disso, dependendo dos usuários no conjunto de dados. As diferentes características dos usuários, incluindo a forma como as características biométricas mudam com o tempo, sugerem que as estratégias de adaptação deveriam ser escolhidas por usuário. Isso motivou a proposta de um sistema biométrico adaptativo modular, chamado ModBioS, que pode escolher cada um desses aspectos por usuário. O ModBioS é capaz de generalizar diversos sistemas baseline e propostas apresentadas nesta tese em um framework modular, juntamente com a possibilidade de atribuir estratégias de adaptação diferentes por usuário. Resultados experimentais mostraram que o sistema biométrico adaptativo modular pode superar diversos sistemas baseline, enquanto que abre um grande número de oportunidades para trabalhos futuros.
19

Capacidade funcional, atividades de vida diária, atividade física, estilo de vida e deterioração cognitiva de pessoas com Síndrome de Down maiores de 20 anos / Functional capacity, Activities of Daily Living, Physical Activity, Lifestyles and Deterioration Cognitive people with higher Down Syndrome 20 Years.

Silveira, Jennifer Rodrigues 25 August 2016 (has links)
Submitted by Anelise Milech (anelisemilech@gmail.com) on 2017-11-07T13:44:43Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Jennifer Rodrigues Silveira.pdf: 1408769 bytes, checksum: 47d2f27d1597cd5156c8542574ab85c2 (MD5) / Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2018-01-02T13:20:04Z (GMT) No. of bitstreams: 2 Jennifer Rodrigues Silveira.pdf: 1408769 bytes, checksum: 47d2f27d1597cd5156c8542574ab85c2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2018-01-02T13:21:59Z (GMT) No. of bitstreams: 2 Jennifer Rodrigues Silveira.pdf: 1408769 bytes, checksum: 47d2f27d1597cd5156c8542574ab85c2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-01-02T13:22:11Z (GMT). No. of bitstreams: 2 Jennifer Rodrigues Silveira.pdf: 1408769 bytes, checksum: 47d2f27d1597cd5156c8542574ab85c2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-08-25 / O presente estudo tem como objetivo verificar se existe associação entre a capacidade funcional e os níveis de atividade física, deterioração cognitiva, e atividades de vida diária, em pessoas com Síndrome de Down maiores de 20 anos. A amostra foi composta por 32 indivíduos moradores da zona urbana e rural da cidade de Pelotas/RS. O estudo prevê a avaliação das capacidades funcionais (CF), das atividades de vida diária (AVD), dos níveis de atividade física (AF), deterioração cognitiva (DC) e questões referentes ao estilo de vida. Para análise estatística foram empregados recursos da estatística descritiva. Para as associações o teste do qui-quadrado e Análise de Variância Univariada (ANOVA). Regressão linear para verificar a variabilidade da CF. Foi adotado um nível de significância de 5% e os dados foram tratados no programa SPSS 22. Fizeram parte do estudo 17 (53%) homens e 15 (46,9%) mulheres, com media de idade de 30,94 anos. Encontrou-se 62,6% (N=20) no nível de obesidade. Foram considerados independentes 37,5% (N=11), parcialmente dependentes 34,4% (N=11) e 28,1% (N=9) classificados como dependentes. Cerca de dois terços da amostra foi classificado com baixa e média CF. Dos estudados 75% (N=24) e 70,8% foram considerados inativos no lazer (questionário) e na AF total (acelerômetro) respectivamente. Em média 12 horas do dia são ocupadas com atividade sedentárias. Verificou-se associação significativa entre ter alta CF para o teste de 800 metros e ser ativo. Encontrouse 78,1% (N=25) dos estudados com maior deterioração cognitiva (DC). A menor DC foi associada a melhores resultados de CF para o teste de sentar e deslocar (p=0,04) habilidades manuais (p=0,02) e levantar-se do solo (p=0,03). Na ANOVA a idade (p=0,04) dos 31-40, ser ativo no lazer (p=0,03) e ser ativo na AF total (p=0,03) foram associadas a melhores resultados do teste de 800 metros. Possuir maiores níveis de AF total (p=0,03), maior independência nas AVDs (p=0,04) e menor DC foram associadas com melhores resultados no teste de sentar e deslocar e maior DC (p=0,03) com resultados inferiores no teste de habilidades manuais. Na regressão linear percebeu-se que as variáveis do G1 (grupo 1) (AF lazer, sexo, idade, DC, doenças associadas, IMC, NSE e AVD total) explicam de forma mais consistente a variabilidade das variáveis de CF. Nota-se um aumento no poder aquisitivo, nos níveis de alfabetização e nas oportunidades de emprego. Foram encontradas poucas associações da AF com AVD e CF. Entende-se com os resultados apresentados que, não é apenas pela condição física associada à SD, mas sim em relação às variáveis de estilo de vida e DC que explicam a variabilidade dos resultados CF. / The present study aims to verify the existence of associations between functional capacity and physical activity levels, cognitive deterioration, and daily life activities in people older than 20 years with Down syndrome. The sample was made up of 32 individuals from the urban and rural areas of Pelotas/RS. The study provides an assessment of functional capacity (FC), daily life activities (DLA), levels of physical activity (PA), cognitive deterioration (CD) and issues related to life style. Descriptive statistical resources were used for statistical analysis. Chi-square test and Univariate Analysis of Variance (ANOVA) was used for associations. Linear Regression was used to verify FC variability. A significance level of 5% was adopted and data were treated using the SPSS 22 program. The sample was made up 17 (53%) men and 15 (46,9%) women with an average age of 30.94 years. It was found 62.6% (N=20) at an obesity level, 37,5% (N=11) were considered independent, 34.4% (N=11) partly dependent and 28.1% (N=9) dependent. Around two thirds of the sample was classified at a low and average FC. From the studies, 75% (N=24) and 70.8% were considered inactive at leisure time (questionnaire) and at total PA (accelerometer) respectively. In average, 12 hours a day are used with sedentary activities. A significant association between high FC for the 800meter test and being active was verified. A higher cognitive deterioration was found in 78.1% (N=25) of the participants. The lower CD was associated to the best FC results for the sitting and dislocation test (p=0.04) manual abilities (p=0.02) and standing up from the floor (p=0.03). In ANOVA, age (p=0.04) of 31-40, being active at leisure time (p=0.03) and active at total PA (p=0.03) were associated to the best results in the 800-meter test. Having higher levels of total PA (p=0.03), more independence in DLAs (p=0.04) and lower CD were associated to the best results at the sitting and dislocation tests and higher CD(p=0.03) to lower results in the manual ability test. It was noticed, in the linear regression, that the G1 variables (group 1) (PA at leisure time, sex, age, CD, associated diseases, BMI, NSE and total DLA) explained more consistently the variability of the FC variables. One may notice an increase in buying power, literacy levels and job opportunities. Few associations were found between PA, DLA and FC. The results show that not only physical conditions associated to DS but also variables related to life style and CD explain the variability of the FC results.
20

Biometrics in a data stream context / Biometria em um contexto de fluxo de dados

Paulo Henrique Pisani 10 March 2017 (has links)
The growing presence of the Internet in day-to-day tasks, along with the evolution of computational systems, contributed to increase data exposure. This scenario highlights the need for safer user authentication systems. An alternative to deal with this is by the use of biometric systems. However, biometric features may change over time, an issue that can affect the recognition performance due to an outdated biometric reference. This effect can be called as template ageing in the area of biometrics and as concept drift in machine learning. It raises the need to automatically adapt the biometric reference over time, a task performed by adaptive biometric systems. This thesis studied adaptive biometric systems considering biometrics in a data stream context. In this context, the test is performed on a biometric data stream, in which the query samples are presented one after another to the biometric system. An adaptive biometric system then has to classify each query and adapt the biometric reference. The decision to perform the adaptation is taken by the biometric system. Among the biometric modalities, this thesis focused on behavioural biometrics, particularly on keystroke dynamics and on accelerometer biometrics. Behavioural modalities tend to be subject to faster changes over time than physical modalities. Nevertheless, there were few studies dealing with adaptive biometric systems for behavioural modalities, highlighting a gap to be explored. Throughout the thesis, several aspects to enhance the design of adaptive biometric systems for behavioural modalities in a data stream context were discussed: proposal of adaptation strategies for the immune-based classification algorithm Self-Detector, combination of genuine and impostor models in the Enhanced Template Update framework and application of score normalization to adaptive biometric systems. Based on the investigation of these aspects, it was observed that the best choice for each studied aspect of the adaptive biometric systems can be different depending on the dataset and, furthermore, depending on the users in the dataset. The different user characteristics, including the way that the biometric features change over time, suggests that adaptation strategies should be chosen per user. This motivated the proposal of a modular adaptive biometric system, named ModBioS, which can choose each of these aspects per user. ModBioS is capable of generalizing several baselines and proposals into a single modular framework, along with the possibility of assigning different adaptation strategies per user. Experimental results showed that the modular adaptive biometric system can outperform several baseline systems, while opening a number of new opportunities for future work. / A crescente presença da Internet nas tarefas do dia a dia, juntamente com a evolução dos sistemas computacionais, contribuiu para aumentar a exposição dos dados. Esse cenário evidencia a necessidade de sistemas de autenticação de usuários mais seguros. Uma alternativa para lidar com isso é pelo uso de sistemas biométricos. Contudo, características biométricas podem mudar com o tempo, o que pode afetar o desempenho de reconhecimento devido a uma referência biométrica desatualizada. Esse efeito pode ser chamado de template ageing na área de sistemas biométricos adaptativos ou de mudança de conceito em aprendizado de máquina. Isso levanta a necessidade de adaptar automaticamente a referência biométrica com o tempo, uma tarefa executada por sistemas biométricos adaptativos. Esta tese estudou sistemas biométricos adaptativos considerando biometria em um contexto de fluxo de dados. Neste contexto, o teste é executado em um fluxo de dados biométrico, em que as amostras de consulta são apresentadas uma após a outra para o sistema biométrico. Um sistema biométrico adaptativo deve então classificar cada consulta e adaptar a referência biométrica. A decisão de executar a adaptação é tomada pelo sistema biométrico. Dentre as modalidades biométricas, esta tese foca em biometria comportamental, em particular em dinâmica da digitação e em biometria por acelerômetro. Modalidades comportamentais tendem a ser sujeitas a mudanças mais rápidas do que modalidades físicas. Entretanto, havia poucos estudos lidando com sistemas biométricos adaptativos para modalidades comportamentais, destacando uma lacuna para ser explorada. Ao longo da tese, diversos aspectos para aprimorar o projeto de sistemas biométricos adaptativos para modalidades comportamentais em um contexto de fluxo de dados foram discutidos: proposta de estratégias de adaptação para o algoritmo de classificação imunológico Self-Detector, combinação de modelos genuíno e impostor no framework do Enhanced Template Update e aplicação de normalização de scores em sistemas biométricos adaptativos. Com base na investigação desses aspectos, foi observado que a melhor escolha para cada aspecto estudado dos sistemas biométricos adaptativos pode ser diferente dependendo do conjunto de dados e, além disso, dependendo dos usuários no conjunto de dados. As diferentes características dos usuários, incluindo a forma como as características biométricas mudam com o tempo, sugerem que as estratégias de adaptação deveriam ser escolhidas por usuário. Isso motivou a proposta de um sistema biométrico adaptativo modular, chamado ModBioS, que pode escolher cada um desses aspectos por usuário. O ModBioS é capaz de generalizar diversos sistemas baseline e propostas apresentadas nesta tese em um framework modular, juntamente com a possibilidade de atribuir estratégias de adaptação diferentes por usuário. Resultados experimentais mostraram que o sistema biométrico adaptativo modular pode superar diversos sistemas baseline, enquanto que abre um grande número de oportunidades para trabalhos futuros.

Page generated in 0.0604 seconds