• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 179
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 182
  • 67
  • 54
  • 53
  • 47
  • 41
  • 37
  • 30
  • 25
  • 25
  • 25
  • 22
  • 21
  • 21
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Análise da associação entre aspectos clínicos e polimorfismos no gene da IL-6 e a susceptibilidade à perda de mini-implante para ancoragem ortodôntica / Alexandre Marcelo Reichow ; orientadora, Paula Cristina Trevilatto

Reichow, Alexandre Marcelo January 2012 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2012 / Inclui bibliografias / Os Mini-implantes (MIs) têm sido cada vez mais utilizados para a ancoragem em ortodontia. O sucesso dos MIs podem necessitar de algum grau de osseointegração, o qual é influenciada pela resposta imuno-inflamatória do hospedeiro. A interleucina-6 (IL-6) é / Mini - implant (MI) has increasingly been used for orthodontic anchorage. MI success may require some osseointegration, which is underlined by host immuneinflammatory response. Interleukin-6 (IL-6) is a cytokine widely expressed during the host immune-inf
62

Avaliação Comparativa da Contenção de Molares Superiores Distalizados Realizada por Meio da Placa Lábio-Ativa ou Aparelho Extrabucal

Silva, Rafael Gomes Corrêa 14 March 2007 (has links)
Made available in DSpace on 2016-08-03T16:31:07Z (GMT). No. of bitstreams: 1 RAFAEL CORREA.pdf: 1603774 bytes, checksum: dd0fd6728d5f702748ab386ada58333a (MD5) Previous issue date: 2007-03-14 / The aim of this study was to compare with cephalometric radiographs the dental effects promoted by the use of extraoral headgear and the maxillary lip bumper, installed after distalization of maxillary molars to maintain the distalized position. The distalization of the maxillary molars was made with Cetlin method. The sample consisted of 40 lateral cephalograms of 20 pacients, 6 boys and 14 girls with initial mean age of 11 years and 7 months. They were treated for a mean period of 14 months and 10 days. After distalization, the sample was randomly divided in two groups, where the AEB group utilized the extraoral anchorage by night and the PLA group utilized an integral period superior lip bumper to maintain the distalized molars during alignment and leveling of teeth. After statistics analysis, was found that the in the AEB group, the molars had a mean mesial inclination of 8,220. The upper incisors had a mean lingual inclination of 3,330. In the PLA group, the molars had an mean extrusion of 1,82 mm; mesialization of 3,14 mm; the molars had a mesial tipping of 8,320 ; the incisors had a mean lingual tipping of 5,780 . Comparing the groups, was found that there wasn t any statistical difference between the appliances. Therefore, both appliances showed efficacy as maintainers of distalized molars during alignment and leveling. / O objetivo deste estudo foi comparar cefalometricamente os efeitos dentários promovidos pelo aparelho extrabucal e com a placa lábio-ativa, instalados para a contenção dos molares superiores distalizados previamente com a placa de Cetlin associada ao aparelho extrabucal. A amostra consistiu de 40 telerradiografias em norma lateral, obtidas de 20 pacientes, sendo 6 do sexo masculino e 14 do sexo feminino, com idade média de 11 anos e 7 meses, tratados por um período médio de 14 meses e 10 dias. Após a distalização, que foi feita com a placa de Cetlin associada ao aparelho extrabucal cérvico-occipital, estes pacientes foram divididos aleatoriamente em dois grupos, onde o grupo AEB utilizou o próprio aparelho extrabucal de uso noturno e o grupo PLA utilizou uma placa lábio-ativa superior em período integral, ambos os aparelhos para conter os primeiros molares superiores distalizados durante a fase de alinhamento e nivelamento dentários. Após a análise estatística, verificou-se que no grupo AEB os molares superiores apresentaram apenas uma inclinação para mesial em média de 8,220 . Já os incisivos superiores inclinaram para lingual, em média, 3,330. No grupo PLA, os molares apresentaram extrusão de, em média, 1,82 mm; mesialização de 3,14 mm; e inclinação para mesial de 8,320; já os incisivos inclinaram para lingual 5,780, em média. Ao comparar os resultados dos grupos entre si, verificou-se que não houve diferença estatisticamente significante entre os aparelhos utilizados. Portanto, tanto o aparelho extrabucal, como a placa lábio-ativa apresentaram-se eficazes para a contenção dos molares superiores distalizados durante as fases de alinhamento e nivelamento dentários.
63

Influência do laser de baixa intensidade na movimentação e na ancoragem ortodôntica por meio de tomografia computadorizada

Orlando, Franciele 16 April 2010 (has links)
Made available in DSpace on 2016-08-03T16:31:14Z (GMT). No. of bitstreams: 1 Franciele Orlando.pdf: 1490020 bytes, checksum: 40d5c7d224cda3e96aa6290e53a2447c (MD5) Previous issue date: 2010-04-16 / Este estudo avaliou os efeitos do laser de baixa intensidade na velocidade de movimentação ortodôntica dos caninos durante a fase de retratação e na ancoragem dos molares por meio de tomografia computadorizada de feixe cônico. Foram selecionados 21 pacientes que necessitavam de extração de primeiros pré-molares sendo que 15 apresentavam maloclusão de classe I de Angle e 6 classe II de Angle. Foram avaliados 72 caninos e 72 molares , sendo 72 molares, sendo 42 caninos e 42 molares superiores, e 30 caninos e 30 molares inferiores. A retratação inicial dos caninos foi realizada com arco segmentado 0,014, por mio de mola de níquel titâneo com uma força de 150 g. Um dos caninos foi irradiado com laser de diodo, com o protocolo de aplicação de 0nm/40mW/10J/cm2/04,J por ponto, sendo cinco pontos por vestibular e cinco pontos por lingual na região radicular , totalizando Et=4J. Esta aplicação foi realizada no dia em que foi ativada a mola de retratação, sendo que no canino contralateral foi realizada uma simulação (placebo). Decorridos trinta dias em média, houve nova ativação da mola e aplicação do laser no mesmo canino já irradiado.(AU)
64

Proposta e análise de novos sistemas de ancoragem para End Fittings de Risers flexíveis

Lorio, Diego Andrés January 2016 (has links)
O trabalho apresentado tem como finalidade analisar os sistemas de ancoragem utilizados na fabricação de End Fittings (EF), através de ensaios de dois sistemas de ancoragem alternativos aos utilizados atualmente na indústria. Além disso, é apresentado o desenvolvimento de um modelo de elementos finitos (MEF) que permite a reprodução do comportamento durante o processo de pullout da ancoragem com melhor desempenho. A caracterização dos materiais envolvidos no sistema de ancoragem foi necessária para o desenvolvimento do modelo numérico. Desta forma, o modelo numérico conta com as propriedades elásticas e plásticas dos materiais, fator que influencia o comportamento do sistema assim como os valores de carga necessários para o arrancamento. A comparação das ancoragens propostas foi realizada a partir dos valores de força obtidos por meio de um teste de arrancamento, chamado de pullout. Para isto, arames da armadura de tração de uma linha flowline de 2,5 polegadas foram conformados de acordo à geometria das ancoragens propostas e embebidas em resina epóxi tentando, desta forma, representar de forma simplificada parte do sistema de ancoragem utilizado nos EF. O desempenho das ancoragens foi analisado a partir das curvas de força em função do deslocamento, nas quais se analisou a força máxima de pullout (força máxima de arrancamento), o deslocamento para força máxima de pullout e o valor de rigidez do sistema. Finalmente depois de selecionada a ancoragem com melhor desempenho, os valores experimentais foram comparados com os valores obtidos do modelo numérico, mostrando uma boa aproximação com valores de erro relativo para a força máxima de pullout e rigidez de -1% e 8%, respectivamente. Por fim, propõe-se como trabalho futuro a continuação nos estudos experimentais de pullout com o objetivo de aprofundar o conhecimento sobre os parâmetros que mais influenciam nestes sistemas, através da utilização de novas geometrias e materiais, assim como a normalização do processo de preparação e ensaio das amostras. / The work aims to analyze the anchoring systems used in manufacturing of flexible pipe End Fittings (EF) through the tests of two alternative anchoring systems different of the currently used in the industry. In addition, it is presented the development of a finite element model (MEF) that allows to reproduce the behavior during the pullout process of the anchoring system with the better performance. The characterization of the materials involved in the anchoring system was necessary for the development of the numerical model. In this way, the numerical model include the elastic and plastic properties of materials, factor that influence the behavior of the system as well as the force values needed for the pullout. The comparison of the proposed anchoring systems was performed from the force values obtained through a pullout test. For this, the armor wires of a flowline flexible pipe with a bore of 2.5-inch were conformed according the geometry of the anchoring systems proposed and then were fixed in epoxy resin, trying in this way to represent a simplified form of the anchoring system used in EF. The performance of the anchoring systems was analyzed from the force-displacement curves. The maximum pullout force, the offset for maximum strength of pullout and the stiffness value of the system were used for the analysis. Finally, after selected the anchoring system with better performance, the experimental values were compared with the values obtained from the numerical model. The results showed a good approximation, with a relative error for the maximum pullout force and stiffness of -1% and 8% respectively. As proposal for future works, the author proposes to continue with the experimental studies of pullout in order to enhance the knowledge about the influential parameters in these systems, through the use of new geometries and materials, as well as the standardization of the test samples preparation.
65

Avaliação de resinas epóxi para aplicação em end fittings de dutos flexíveis

Wedekamper, Facundo Javier January 2017 (has links)
Nas extremidades dos dutos flexíveis utilizados na indústria petroleira offshore são instalados os end fittings, ou conectores. Uma parte fundamental deste componente é o sistema de ancoragem, que consiste nos arames de aço da armadura de tração embebidos em resina epóxi, onde seu propósito é transmitir os esforços que provêm do duto. Este estudo tem como objetivo apresentar uma avaliação de três diferentes resinas epóxi (Huntsman: SW404/HY404, AW4804/HW4804 e XAW1395/HY950) comparando as propriedades mecânicas e a influência do ambiente de serviço, a fim de definir qual melhor se adequa para este fim. As propriedades mecânicas das resinas epóxi foram determinadas através de ensaios de compressão, tração, cisalhamento, pullout e medições de dureza. Os denominados ensaios de pullout representam um modelo simplificado do sistema de ancoragem e possibilitam o estudo da interface entre a resina e o aço da armadura de tração. Para avaliar o efeito da exposição do polímero às condições ambientais de serviço, amostras foram envelhecidas numa solução de água marinha na temperatura constante de 60°C, durante um período de 6 meses. Após este período, realizaram-se ensaios de compressão, cisalhamento e pullout, cujos resultados foram comparados com os obtidos de amostras sem nenhum período de exposição. A influência das elevadas temperaturas sobre a propriedade de adesão nas diferentes resinas foi avaliada mediante ensaios de pullout realizados à temperatura de 100°C. Além disto, foi realizada uma análise térmica através de ensaios de TGA e DMTA. Por fim, às propriedades determinadas nos diferentes ensaios e medições lhes foram atribuídas um peso quantitativo de acordo com sua importância dentro do sistema de ancoragem. Os valores das propriedades e seus pesos foram introduzidos a uma matriz de análise de multicritérios, que permitiu selecionar a resina epóxi com a melhor combinação de propriedades para ser aplicada em end fittings. Finalmente, é proposta a determinação de alguns parâmetros adicionais das resinas epóxi para complementar o estudo realizado / End fittings are components that are installed at the ends of flexible pipes used in the offshore oil industry. A fundamental part of this component is the anchoring system, which consists of the steel wires of the tensile armour embedded in epoxy resin, which its purpose is to transmit the loads that come from the pipe. This study aims to present an evaluation of three different epoxy resins (Huntsman: SW404/HY404, AW4804/HW4804 e XAW1395/HY950), comparing the mechanical properties and studying the influence of the service environment, in order to define which material is best suited for this application. The mechanical properties of the epoxy resins were determined by tests such as compression, tensile, shear and pullout tests and hardness measurements. The pullout tests represent a simplified model of the anchoring system and they allow the study of the interface between the resin and the steel of the tensile armour. To evaluate the effect of the exposition of the polymer material to environmental conditions found in service, some samples were immersed in a bath of sea water at a constant temperature of 60°C during a period of 6 months. After this period, compression, shear and pullout tests were performed and the results were compared with those obtained from samples without degradation. The influence of the high temperatures on the adhesion property of the different epoxy resins was evaluated with pullout tests performed at a temperature of 100°C. Furthermore, a thermal analysis was realized through TGA and DMTA tests. Finally, to the properties determined in the different tests and measurements were given a quantitative weight according to their importance within the anchoring system. The values of the properties and their weights were introduced into a matrix of multicriterial analysis that allowed selecting the epoxy resin with the best combination of properties to be applied in end fittings. Finally, it was proposed the determination of other epoxy resins parameters to complement this study.
66

Comparação tridimensional dos efeitos dentários de duas mecânicas para fechamento de espaço: estudo preliminar / Three-dimensional comparison of dental effects of two mechanics for space closure: a preliminary study

Camila de Sousa Dardengo 17 December 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As más oclusões de Classe I com biprotrusão dentária são caracterizadas pela projeção dos incisivos superiores e inferiores e podem ser corrigidas com extrações de primeiros pré-molares, permitindo reposicionar os incisivos, usando como ancoragem os dentes posteriores. Esse trabalho teve como objetivo comparar, por meio de superposição de modelos tridimensionais, a movimentação de molares e de incisivos com duas técnicas para fechamento de espaços. Foram selecionados, tomografados (T0) e distribuídos, aleatoriamente em dois grupos, seis pacientes com indicação de exodontia de quatro primeiros pré-molares. No grupo 1 (n=3) foi feito o fechamento dos espaços das extrações em uma única etapa (fechamento em massa) e no grupo 2 (n=3), em duas etapas (distalização de caninos seguida da retração de incisivos). Após o completo fechamento dos espaços foi solicitada nova tomografia (T1). Os modelos tridimensionais em T0 e T1 para os dois grupos foram superpostos para descrever e quantificar a movimentação ocorrida nos primeiros molares. A retração de incisivos foi avaliada de maneira bidimensional. Os molares superiores e inferiores do grupo 1 sofreram movimentação mesial de translação, enquanto os do grupo 2, apresentaram deslocamento de coroa maior do que de ápice radicular, demonstrando movimento de inclinação mesial de coroa. Ao se comparar o movimento mesial dos molares entre os dois grupos, observou-se que no grupo 1 houve maior movimentação mesial da raiz mésio-vestibular dos molares superiores (p=0,009). No entanto, em ambos os grupos os molares superiores giraram sobre a raiz palatina. No arco inferior verificou-se maior movimento mesial de coroa para o grupo 2 (p=0,015). A análise da movimentação dos incisivos apresentou variações semelhantes para as medidas lineares e angulares dos incisivos superiores nos dois grupos. Já, para as medidas angulares dos incisivos inferiores, observou-se que o grupo 1 apresentou menor controle de torque. O tempo de tratamento de todos os pacientes da amostra foi superior a 30 meses, exceto um paciente que apresentou tempo de tratamento inferior a 24 meses. Pôde-se concluir que a perda de ancoragem ocorreu por movimento de translação no fechamento de espaços em massa, e por inclinação mesial no fechamento de espaços em duas etapas, para ambos os arcos. Parece haver maior movimentação mesial radicular nos molares superiores no fechamento em massa e maior movimento mesial de coroa dos molares inferiores para o fechamento em duas etapas. Sugere-se que não há diferença na retração dos incisivos superiores e maior retroinclinação dos incisivos inferiores no fechamento de espaços em duas etapas. / Class I malocclusions with dental biprotrusion are characterized by the projection of upper and lower incisors and can be corrected with extractions of four first premolars, allowing incisor retraction using the posterior teeth as anchorage. The purpose of this research was to compare the movement of molars and incisors, by superimpostions of three-dimensional models, with two space closure techniques. Six patients with indication for four first premolar extractions were selected, tomographed (T0) and randomly assigned to two groups. For Group 1 (n=3) premolar extraction space closure was performed in one-stage (en masse retraction) and for group 2 (n=3) in two stages (canine retraction followed by incisor retraction). After complete space closure, a new tomograph was taken (T1). The three-dimensional models, in T0 and T1, for both groups were superimposed to describe and quantify first molar movement. Incisor retraction was evaluated in two dimensions. The upper and lower molars in group 1 presented bodily mesial movement, while those in group 2, presented greater crown than root movement, demonstrating mesial crown tipping. When the amount of mesial molar movement was compared between the two groups, a greater mesial root movement was observed for upper molars in group 1 (p=0.009). However, in both groups the upper molars rotated aroung the palatal root. In the lower arch, a greater mesial crown movement was observed in group 2 (p=0.015). Incisor movement analysis presented similar variations for linear and angular measurements for upper incisors in both groups. In contrast, the angular measurements for the lower incisors demonstrated more torque control in group 2. The treatment time for all patients in the sample was greater than 30 months, with the exception of one patient, who presented treatment time smaller than 24 months. In conclusion, anchorage loss ocurred by bodily movement in en masse space closure and by mesial crown tipping in two-stage space closure, in both arches. In addition, there might be greater mesial root movement for upper molars in en masse space closure and greater mesial crown movement in two-stage space closure. It can also be suggested that there are no differences in upper incisor retraction and there is greater lower incisor uprighting in two-stage space closure.
67

AVALIAÇÃO DO TORQUE DE FRATURA DE MINI-IMPLANTES SUBMETIDOS À ATÉ TRÊS REUTILIZAÇÕES / STUDY OF THE EFFECTS OF STERILIZATION AND REUSE OF MINI-SCREWS, UP TO THREE TIMES, ON TORQUE REQUIRED TO FRACTURE

Miotti, Fabrício Lamberti 29 July 2016 (has links)
Orthodontists have been reusing mini-implants that fail after installation or that will be inserted in a new place due to mechanic needs in order to optimize clinical time. The aim of this study was to simulate the reuse of mini-implants up to three times and evaluate their potential weakness. We used 48 screws (Morelli, Sorocaba, Brazil), which were divided into four groups: C= Control, G1 = one reuse, G2 = two reuse, G3 = three reuse. In order to simulate inserts in patients mouths, we used pig iliac bone. After we insert screws on bone specimen, we removed, cleaned, and sterilized them by autoclaving. The guide at the machine we used allowed us to standardize installations. After all groups were submitted to their reuse periods, mini-implants were submitted to fracture, and the strongest force necessary to break them was measured by a digital axial torquemeter. We used bovine tibia specimens for fracture, because of its greater bone cortical and bone density. We used One Way ANOVA (Bonferroni post-hoc) to compare means of each group. Results showed differences statistically significant between G3 and the other groups. All mini-implants needed strength higher than recommended by the literature to be inserted into patients, even though we found differences in fracture resistance between groups. / Na busca por não perder tempo clínico, ortodontistas vêm reutilizando mini-implantes que falham após a instalação ou que serão instalados em novo local devido à necessidades mecânicas. O objetivo deste estudo foi simular a reutilização de miniimplantes em até três vezes e avaliar a possível fragilização dos mesmos. Para isso, foram utilizados 48 parafusos (Morelli Sorocaba-SP, Brasil), os quais foram divididos em quatro grupos: C = Controle, G1 = uma reutilização, G2 = duas reutilizações e G3 = três reutilizações. Para simular, laboratorialmente, as instalações em boca nos pacientes, foi utilizado osso ilíaco suíno. Após serem inseridos no espécime de osso, os parafusos foram removidos, limpos e esterilizados em autoclave. Com um guia presente na máquina utilizada foi possível padronizar as instalações. Após todos os grupos passarem pelos ciclos de reutilização correspondentes, os mini-implantes foram submetidos à fratura, e a força máxima necessária para a quebra foi medida através de um torquímetro digital axial. Para a fratura, foram utilizados espécimes de tíbia bovina, por possuir maior densidade óssea e espessura de cortical. Os valores médios dos grupos foram analisados pela ANOVA de 1 fator com post-hoc em Bonferroni. Foram encontradas diferenças estatisticamente significativas entre o grupo G3 e os demais grupos. Mesmo com as diferenças na resistência à fratura entre os grupos, todos necessitaram de forças superiores às recomendadas para instalação em pacientes.
68

Minimplante e botão lingual como ancoragem para retração inicial de caninos superiores: estudo prospectivo

Arantes, Flávia de Moraes [UNESP] 29 May 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-29Bitstream added on 2014-06-13T21:05:59Z : No. of bitstreams: 1 arantes_fm_dr_araca.pdf: 917045 bytes, checksum: 35b80ca88f794114ea01fe8fe638b23f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A preocupação com a ancoragem é um dos principais fatores a serem considerados no planejamento de um tratamento ortodôntico. Entendem-se como ancoragem os procedimentos intra e extrabucal em que um ou mais dentes ou dispositivos ortodônticos são utilizados como apoio para movimentar outros dentes. A utilização mais frequente dos implantes decorre de uma menor colaboração do paciente, não prejudica a sua estética e ainda cria um sistema de forças mais definido. Por essas razões e pela utilização clínica dos minimplantes de forma indiscriminada, surgiu o interesse em estudar a perda de ancoragem relacionada aos minimplantes. O objetivo deste trabalho foi comparar, por meio de telerradiografias, panorâmicas e modelos, a perda de ancoragem após a retração inicial de caninos superiores entre dois grupos. Foram selecionados 18 pacientes, divididos em dois grupos aleatórios de 9 indivíduos cada um (A e B), triados para tratamento ortodôntico na Faculdade de Odontologia de Araçatuba – UNESP, Disciplina de Ortodontia. O grupo A utilizou o minimplante enquanto o grupo B utilizou botão lingual. Para todos os pacientes foram realizadas duas telerradiografias (T1 e T2), duas panorâmicas (P1 e P2) e dois modelos (M1 e M2). Os primeiros exames complementares foram realizados ao início (T1, P1 e M1), e o outro, ao final da retração inicial de canino (T2, P2 e M2). Foi eleita a segunda fase (retração inicial de canino), devido à grande perda de ancoragem que se tem neste estágio do tratamento. Todas as medidas foram tabuladas e submetidas a análise estatística. Para comparação entre as fases Início e Após foi utilizado o teste “t” pareado. Para a comparação entre os grupos de minimplante e botão lingual foi utilizado o teste “t” de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Todos os cálculos... / The concern with the anchorage is one of the main factors to be considered when planning an orthodontic treatment. Anchorage comprehends intra and extraoral procedures in which one or more teeth or orthodontic devices are used as a support for moving other teeth. The use more constant of implants is derived from a poor patient collaboration, does not impair the esthetics and still creates more defined forces system. For these reasons and because of the mini-implants clinical utilization in an indiscriminate way, there was an increased interest in studying anchorage loss related to mini-implants. The purpose of this study was to compare, by means of teleradiographies, panoramic radiographs and models, the anchorage loss after initial maxillary canine retraction between two groups. Eighteen patients were selected, then randomly divided into two groups of 9 individuals each (A and B), and elected for orthodontic treatment in the Faculty of Dentistry of Araçatuba – UNESP, Orthodontics Department. Group A utilized mini-implant while group B utilized lingual button. For all patients, two teleradiographies (T1 and T2), two panoramic radiographs (P1 and P2) and two models (M1 and M2) were done. The first complementary exams were accomplished in the beginning (T1, P1 and M1) and the other in the end of the initial canine retraction (T2, P2, and M2). The second phase was elected (initial canine retraction) due to the great anchorage loss that exists in this treatment stage. All measurements were tabulated and submitted to statistical analysis. For the comparison between the stages “Beginning” and “After”, a paired t test was used. For the comparison between the mini-implant and lingual button groups, a Student’s t test for independent measurements was used. In all tests, a significance level of 5% (p<0,05) was adopted. All statistical calculations... (Complete abstract click electronic access below)
69

Avaliação da vida em fadiga de um novo modelo de terminal conector para dutos flexíveis

Xavier, Flávio Galdino January 2009 (has links)
Este trabalho foca a avaliação da vida em fadiga de um novo modelo de terminal conector para dutos flexíveis (risers) de camadas não aderentes (unbonded). Os ensaios foram feitos levando em consideração apenas a parte estrutural desses dutos, de forma a ensaiar uma nova configuração de ancoragem da armadura de tração encontrada nesse equipamento conhecido como terminal conector (end fitting). É dentro deste componente que os arames da armadura de tração são fixados por resina epóxi em conjunto com uma configuração específica permitindo dessa maneira a sustentação do duto flexível quando fixado a plataformas offshore. Para a escolha do novo modelo de ancoragem aqui proposto, além de se tomar como referência, fez-se também uma analogia aos modelos utilizados nas ancoragens das barras metálicas utilizadas em concreto protendido. Isto foi feito por entender que algumas características mecânicas da resina epóxi aproximam-se das do concreto. Para a definição do novo modelo de ancoragem, uma análise simplificada, utilizando o Método dos Elementos Finitos (MEF), foi feita em dois modelos de ancoragens recomendados na API RP 17B (2002) e utilizado por alguns fabricantes, no intuito de verificar as distribuições das tensões ao longo desses arames dentro do terminal conector quando envolto pela resina epóxi. Esta análise destacou as regiões ao longo dos arames onde havia concentrações das tensões. Utilizando-se dessas informações, foi desenvolvida uma nova configuração para o arame dentro da resina de maneira a minimizar esses concentradores de tensão, permitindo assim que o modelo de ancoragem proposto tenha um melhor desempenho em fadiga. Para tanto, as verificações desses modelos feitas através do MEF e validadas através de ensaios experimentais em escala reduzida, mostraram que o modelo proposto apresentou reduções do KT da ordem de 16,5% e das tensões na resina de 60% quando comparados aos outros dois modelos comerciais. Após essas avaliações protótipos do novo terminal conector foram confeccionados em escala real e montado a dois pedaços de duto flexível de 2,5" de diâmetro, compondo assim dois corpos de prova: o CP1 e o CP2, os quais foram submetidos a ensaios de tração estáticos e carregamentos dinâmicos. Nos ensaios o CP1 foi submetido a uma carga máxima em tração de 844 kN e após esse carregamento, a não evidência de ruptura nos arames da armadura de tração o levou para o ensaio de fadiga com cargas em tração variando entre 130 e 304 kN a uma freqüência de 1Hz para uma vida de 1.000.000 de ciclos de carga. O resultado desse ensaio mostrou a viabilidade do conceito, uma vez que se atingiu a 1.000.000 de ciclos de carga sem a ruptura de qualquer arame dentro do terminal conector, evidenciado através da dissecação. Para finalizar os trabalhos, um segundo corpo de prova (CP2) foi confeccionado, obedecendo as recomendações estipuladas na API RP 17B (2002). Ensaiado com os mesmos parâmetros do CP1, se conseguiu levá-lo a fase de Dano igual a 1. Ao final desse ensaio observaram-se a ruptura de alguns arames na região mediana sobre o duto flexível que unia os dois conectores. Já as dissecações não mostraram evidências de arames rompidos internamente aos conectores. / This work focuses on the evaluation of the fatigue of life in a new model of end fitting for unbounded flexible pipe (risers). The tests had been made taking in consideration only the structural part of these risers, in order to test a new configuration of anchorage of the tensile armor found in equipment known as an end fitting. It is inside of this component that the tensile armor wires are fixed by epoxy resin in the set with specific configuration in this way allowing the sustentation these flexible pipes when the fixed offshore platforms. For the choice of the new model of anchorage considered here, beyond the reference if taking an analogy to the models used in the anchorage dues ones of the metallic bars used in prestressed concrete. This was made by understanding that some mechanical characteristics of the epoxy resin are come close to the concrete. For the definition of the new model of anchorage, the simplified analysis, using the Finite Element Method (FEM), was made in two models of anchorage dues recommended in API RP 17B (2002) and used by some manufacturers, in intention to verify the distributions tensions along the wires within of the end fitting when wrapped for the epoxy resin. This analysis highlighted the wires throughout the regions where it had concentrations of the tensions. Using these information of itself, a new configuration for the wire inside of the way resin was developed to minimize these concentrators of tension as soon as, allowing anchorage of the considered model one has better performance in fatigue. For in such a way, the verifications of these models made through the FEM and validated through experimental tests in reduced scale, had shown that the considered model presented reductions of the KT of the order of 16.5% and stress in the resin of 60% when compared with the others two commercial models. After these evaluations archetypes of connecting the new end fitting had been confectioned in real scale and mounted two pieces of flexible pipe of 2.5" of diameter, thus composing test of two bodies: the CP1 and the CP2, which had been submitted the static tension tests and dynamic loads tests. In the tests the CP1 was submitted to tension in the maximum load of 844 kN and after this shipment, the evidence of rupture in the wires of armor did not take the tension it for the tests of fatigue in traction with loads varying between 130 and 304 kN to the frequency of 1Hz for a life of 1,000,000 cycles of load. The result of this test showed the viability of the concept, that if the team reached the inside of 1,000,000 load cycles without the rupture of any wire of the end fitting, evidenced through the dissection. To finish the works, the body of the test (CP2) it was confectioned, obeying to the recommendations stipulated in API RP 17B (2002). Tested with the same parameters of CP1, were taken to the stage Damage equal to 1. To the end of this test they had observed it rupture of some wires in the region on the medium flexible pipe that joined the two end fittings. Already the dissections had not shown evidence of broken internally wires to the end fittings.
70

Influência do diâmetro, comprimento e angulação nos torques de inserção e remoção de mini-implantes autoperfurantes /

Pignatta, Lilian Maria Brisque. January 2011 (has links)
Orientador: Eduardo César Almada Santos / Coorientador: Francisco Antonio Bertoz / Banca: Marcos Rogério de Mendonça / Banca: Paulo Henrique dos Santos / Banca: Maurício Tatsuei Sakima / Banca: Júlio de Araújo Gurgel / Resumo: Objetivo: avaliar a influência da associação do diâmetro, comprimento e angulação do mini-implante sobre a estabilidade primária a partir da análise do torque de inserção e remoção. Material e método: foram instalados 120 mini-implantes autoperfurantes, cilíndricos, com 1,4 x 6mm, 1,4 x 8mm, 1,6 x 6mm e 1,6 x 8mm, em um bloco de osso artificial. Os mini-implantes foram instalados com o auxílio da chave de mão acoplada ao torquímetro digital, possibilitando a inserção e mensuração do torque com orientação perpendicular e com inclinação de 60° em relação à superfície do bloco de osso artificial. Os mini-implantes foram removidos da mesma forma como inseridos, porém girando-se a chave em sentido anti-horário. Os registros foram realizados através da conexão do torquímetro ao computador e os valores do torque de inserção e remoção foram obtidos pelos picos máximos dos gráficos, registrados pelo software Datalogger e compilados em tabelas. Realizou-se a análise descritiva para obter a média e desvio-padrão de cada grupo, e submeteram-se os resultados à análise de variância (ANOVA). Resultados: a média dos torques variou entre 19,2 a 23,6Ncm nos testes de inserção e entre 11 a 14,66Ncm nos testes de remoção. Conclusões: as variáveis diâmetro e comprimento não exerceram influência significativa nos valores dos torques de inserção e remoção. A angulação de instalação ocasionou aumento significativo desses torques no grupo 7. Os demais grupos, porém, não apresentaram diferença significante entre as angulações / Abstract: Objective: evaluate the influence of diameter, length and angulation of mini-implant on the primary stability through the analysis of insertion and removal torque. Material and Methods: were installed 120 self-drilling mini-implants, cylindrical, with 1.4 x 6mm, 1.4 x 8mm, 1.6 x 6mm and 1.6 x 8mm in a block of artificial bone. The screwdriver for mini-implants was connected to digital torquimeter, in order to allow the insertion and measurement of torque oriented perpendicular and slanting at 60° to the bone surface. Mini-implants were removed the using the same procedures, but turning the screw driver counterclockwise. The recordings were made by connecting the torquimeter to the computer and values of insertion and removal torque were obtained by the maximum peak of the graphics, collected by the Datalogger software and compiled into tables. We conducted a descriptive analysis for the mean and standard deviation of each group, and the results submitted to analysis of variance (ANOVA). Results: the mean torques ranged from 19.2 to 23.6Ncm for insertion tests and between 11 to 14.66Ncm for removal tests. Conclusions: the diameter and length did not influence significantly the values of insertion and removal torques. The angle of installation of these torques caused a significant increase in group 7. However, the other groups showed no significant difference between the angles / Doutor

Page generated in 0.0706 seconds