• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 685
  • 69
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 764
  • 346
  • 123
  • 112
  • 94
  • 69
  • 68
  • 66
  • 65
  • 58
  • 58
  • 57
  • 51
  • 49
  • 48
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Comparación de la eficacia anestésica de la Técnica Infiltrativa Vestibular y la Técnica Estándar en relación al dolor producido por exodoncias de premolares superiores

Maldonado Luna, Hugo Alejandro January 2011 (has links)
El presente estudio tiene como objetivo principal determinar la eficacia analgésica de la técnica infiltrativa vestibular en relación con la técnica estándar utilizando articaína 4% con epinefrina 1:100000, en el control del dolor producido por exodoncias de premolares superiores por indicación ortodóncica. Se utilizó la escala conductual de Campbell para evaluar el dolor a través de las reacciones y gestos de los pacientes. También se utilizaron la Escala Visual Análoga (EVA) y la Escala de Respuesta Verbal (ERV). Se evaluaron 40 pacientes mayores de 11 años y menores de 18 años de edad de ambos géneros, divididos en dos grupos de 20 pacientes cada uno, un grupo para la técnica estándar y el otro para la técnica vestibular. Utilizando la Escala Conductual se halló que 19 pacientes (95%) del grupo de la técnica estándar mostraron tener un dolor leve o nulo. Mientras que en el grupo de la técnica vestibular, se halló que 17 pacientes (85%) tuvieron un dolor leve o nulo. Al comparar los resultados con la prueba estadística Chi cuadrado no se encontró diferencia estadísticamente significativa entre ambas técnicas. El valor promedio para la EVA encontrado en el grupo de la técnica estándar fue de 14.40 ± 4.5 mm. Mientras que para el grupo de la técnica vestibular se obtuvo una EVA promedio de 21.45 ± 3.5 mm. La prueba t de Student demostró que no existe diferencia estadísticamente significativa entre ambas técnicas. Con respecto a la ERV, se halló que con la técnica estándar 16 pacientes (80%) manifestaron un dolor “menor de lo esperado”, mientras que con la técnica vestibular fueron 12 pacientes (60 %). La prueba de Chi cuadrado demostró que no existe diferencia estadísticamente significativa entre ambas técnicas. Con los resultados obtenidos en el presente estudio se puede concluir que la eficacia anestésica de la técnica de administración estándar es similar a la eficacia anestésica de la técnica vestibular utilizando la articaína al 4% con epinefrina 1:100000 en exodoncias de premolares superiores por indicación ortodóncica. PALABRAS CLAVES: articaína al 4%, escala conductual de Campbell, EVA, ERV, anestesia palatina, anestesia vestibular. / Tesis
42

Estudio comparativo de las condiciones de intubación entre la técnica de capacidad vital con sevoflurane al 8% y óxido nitroso al 75% versus propofol, fentanyl y rocuronio

Román Loayza, Eduardo January 2003 (has links)
El presente trabajo es un estudio randomizado, prospectivo, comparativo, que se realizó para comparar las condiciones de intubación que se obtuvieron al hacer la inducción con sevoflurane al 8% y óxido nitroso al 75% versus fentanyl, propofol y rocuronio. Se randomizaron a un total de 60 pacientes para recibir sevoflurane ó propofol para la intubación endotraqueal. A todos los pacientes se les colocó una cánula intravenosa y se pasó entre 5 a 7 ml/kg de suero fisiológico previo a la inducción. A los pacientes que recibieron la técnica de inducción por capacidad vital, se les instruyó en la manera de colaborar, mientras se colocaba una mascarilla para recibir oxígeno al 100% se procedió a hacer el sebado en el circuito con sevoflurane al 8% y óxido nitroso al 75% por aproximadamente 2 minutos, luego se les hizo respirar dicha muestra, hasta la pérdida del reflejo parpebral, momento en el cual se procedió a ventilar manualmente hasta el momento en que se llegue a una concentración espirada de sevoflurane al 6%, procediendo a la intubación endotraqueal. Para el grupo de propofol y rocuronio, se comenzó la inducción con fentanyl de 2.5 ug./Kg., luego de dos minutos se les administró propofol a una dosis de 2 mgs/Kg, en el momento que perdieron el reflejo parpebral se administró rocuronio a 0.9 mgs. Kg y a los 90 segundos se procedió a la intubación endotraqueal. Criterios de relajación mandibular, posición de las cuerdas vocales, y respuesta a la intubación endotraqueal se usaron para evaluar las condiciones de intubación.. Si el score de intubación era menor ó igual a 7 era considerado como aceptable, de otra manera era descrito como condiciones inaceptables de intubación. La intubación endotraqueal fué exitosa en todos los pacientes, en ambos grupos las condiciones de intubación que se presentaron fueron calificadas como excelentes, un paciente de cada grupo presentó cuerdas vocales en movimiento al momento de la laringoscopia y dos pacientes del grupo de propofol y rocuronio presentaron tos y 3 pacientes del grupo de sevoflurane presentó tos, no encontrándose diferencia significativa entre ambos grupos.. Por lo tanto se concluye que la técnica por capacidad vital con sevoflurane al 8% y óxido nitroso al 75% es una buena alternativa para la intubación endotraqueal en adultos.
43

O propofol na anestesia intravenosa total equina

Bora, Luiz Fernando January 2016 (has links)
Orientador : Prof. Dr. Ricardo G. D. Vilani / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências Agrárias, Programa de Pós-Graduação em Ciências Veterinárias. Defesa: Curitiba, 30/03/2016 / Inclui referências : f.84-87 / Área de concentração : Ciências Veterinárias / Resumo: A anestesia equina apresenta elevada taxa de mortalidade em comparação com outras espécies animais e seres humanos, em parte devido à ampla utilização de agentes inalatórios como único agente anestésico, promovendo importante depressão cardiovascular e respiratória. A utilização de analgésicos é fundamental para uma anestesia balanceada, auxiliando na diminuição do requerimento do anestésico de manutenção, apesar de restrições devido a particularidades da espécie equina, falta de novas opções e associações analgésicas. A anestesia total intravenosa (TIVA), com uso de anestésicos e analgésicos exclusivamente pela via intravenosa, possui o propofol como principal agente e pode ser uma boa opção ao uso dos anestésicos voláteis. Esta pesquisa teve como objetivos avaliar a utilização de propofol em infusão contínua para cirurgias de rotina e anestesias experimentais com diferentes analgésicos (lidocaína e cetamina, remifentanil e lidocaína). Foram realizados 47 procedimentos anestésicos, sendo dez anestesias experimentais e 37 pertencentes a rotina hospitalar. Esta pesquisa foi dividida em três etapas. A primeira etapa estabeleceu a taxa de infusão de propofol com lidocaína e cetamina, correlacionando a taxa de infusão de propofol com variáveis dos pacientes e dos procedimentos, em 19 cavalos submetidos a cirurgias diversas. A segunda etapa avaliou variáveis cardiovasculares, respiratórias e hemodinâmicas em dez anestesias experimentais com utilização de infusão contínua de propofol ou isofluorano em associação à infusão contínua de remifentanil, para cavalos saudáveis em decúbito lateral e dorsal. A terceira etapa comparou a utilização de infusão contínua de propofol com o anestésico inalatório isofluorano em associação com infusão contínua de lidocaína para 18 cirurgias de laparotomia exploratória devido à cólica equina. Nas três etapas foram realizadas avaliações dos parâmetros fisiológicos, hemogasométricos, qualidade da indução anestésica, tempo e qualidade da recuperação anestésica e as apropriadas correlações. O requerimento de propofol foi maior em potros em comparação com cavalos adultos em cavalos anestesiados com propofol, lidocaína e cetamina. A associação de propofol com remifentanil em decúbito dorsal promoveu melhor estabilidade hemodinâmica em comparação com isofluorano e remifentanil. A associação de propofol e lidocaína em cavalos anestesiados para laparotomia exploratória foi semelhante para as variáveis cardiovasculares e recuperação anestésica, apesar de leve hipercapnia no grupo propofol e maior requerimento de dobutamina no grupo isofluorano. De forma geral o propofol produziu anestesia satisfatória, com boa estabilidade cardiovascular e hemodinâmica, apesar da recuperação anestésica mais longa após período prolongado de infusão, porém sem alterar a qualidade da recuperação. / Abstract: Equine anesthesia presents high rate of deaths compared to other animal species and human patients, partially because of the wide use of inhalational agents as a single anesthetic agent, resulting in significant cardiovascular and respiratory depression. The use of analgesics is essential for a balanced anesthesia, assisting in reduction of maintenance anesthetic, although there are restrictions due to particularities of the equine specie, lack of new options and analgesic associations.Total intravenous anesthesia (TIVA), with the use of analgesics and anesthetics exclusively intravenously, has propofol as a main agent and may be a good option to the use of volatile anesthetics. This study aimedto evaluate the use of continuous infusion of propofol for routine surgeries and experimental anestesias with different analgesics (lidocaine and ketamine, remifentanil and lidocaine). 47 anesthetic procedures were performed, ten experimental anesthesias and 37 clinical anesthesia. This study was divided into three parts.The first part established the required infusion rate of propofol with lidocaine and ketamine in 19 horses divided in foals and adult horses, undergoing surgeries. The second part assessed cardiovascular, respiratory and hemodynamic variables in ten experimental anesthesia with the use of continuous infusion of propofol or isoflurane in combination with continuous infusion of remifentanil for healthy horses in lateral and dorsal recumbency. The third part compared the use of continuous infusion of propofol to isoflurane in combination with continuous infusion of lidocaine for 18 exploratory laparotomy surgeries in horses with colic syndrome. In the three studies were evaluated physiological parameters, blood gas analysis, quality of induction of anesthesia, time and quality of anesthetic recovery and appropriate correlations. Propofol requirement was higher in foals compared to adult horses in anesthesia with propofol, lidocaine and ketamine. Propofol associated with remifentanil in dorsal recumbency showed better hemodynamic stability compared to isoflurane and remifentanil. The association of propofol and lidocaine for anesthetized horses for exploratory laparotomy showed anesthetic recovery and cardiovascular variables similar compared to isoflurane and remifentanil, although slight hypercapnia in propofol group and higher dobutamine application in isoflurane group. In general propofol produced satisfactory anesthesia with good cardiovascular and hemodynamic stability although longer anesthetic recovery after prolonged infusion, but without changing the quality of recovery.
44

Avaliação da influência da medicação pré-anestésica sobre os efeitos da anestesia geral intravenosa nos parâmetros endócrinos e metabólicos relacionados ao estresse em eqüinos

Castro Junior, Jarbas Francisco da Costa January 2003 (has links)
O estresse é considerado ao mesmo tempo um mecanismo de defesa contra diferentes fatores agressores e a causa de importantes alterações orgânicas que podem levar ao estabelecimento de estados mórbidos. A definição de estresse em animais é tema de controvérsia, no entanto a ativação do eixo hipotalâmico-hipofisário-adrenal (HHA) é utilizado como parâmetro para avaliação do grau de alteração imposto. Em eqüinos, a anestesia isoladamente pode desencadear a cascata de eventos ligados ao estresse, não necessitando como em outras espécies a participação de intervenções cirúrgicas. No entanto, a anestesia geral intravenosa têm sido considerada como menos agressiva e conseqüentemente não desencadeadora de estresse. No presente estudo foi avaliado uma combinação para indução anestésica, a tiletamina-zolazepam (TZ=1,1 mg.kg-1), tendo como medicação pré-anestésica a romifidina (80 µg.kg-1), utilizada isolada ou associada a acepromazina (0,08 mg.kg-1) ou diazepam (0,1 mg. .kg-1). A romifidina é um agonista adrenérgico α-2, de marcada ação sedativa e miorrelaxante. A acepromazina é um derivado fenotiazínico cuja ação tranqüilizante tem sido aplicada na combinação com diversos outros fármacos para indução anestésica. O diazepam é considerado o benzodiazepínico clássico, com atividade ansiolítica e miorrelaxante. Os três fármacos são de uso corrente na medicina veterinária eqüina. A tiletamina é uma ciclohexamina de ação semelhante à cetamina e é disponível comercialmente associada ao zolazepam, na proporção de 1:1. Foram utilizados neste trabalho 24 eqüinos de ambos os sexos, diferentes idades e raças, todos enquadrados na categoria ASA I (American Society of Anesthesiologists). Os animais foram divididos aleatoriamente em três grupos. Os grupos, foram definidos pela combinação pré-anestésica como RTZ (romifidina), ARTZ (acepromazina + romifidina) e DRTZ (diazepam + romifidina). Os fármacos foram administrados por via intravenosa. Entre a romifidina e TZ foi estabelecido um intervalo de 10 minutos em todos os grupos, entre a acepromazina e a romifidina um período de 30 minutos e, a partir da administração de diazepam, houve uma pausa de 3 horas até a romifidina. As colheitas de sangue para as dosagens hormonais foram realizadas em três tempos nos grupos RTZ e ARTZ. Antes de qualquer fármaco (P), após a administração da MPA (M) e 15 minutos após a indução (I). No grupo DRTZ, como se desejava avaliar o efeito do benzodiazepínico isolado, foi realizada uma quarta colheita antes da administração de romifidina (B). Para os demais parâmetros os tempos considerados foram P e I. Foram avaliados a concentração plasmática de ACTH e cortisol, a concentração sérica de glicose e lactato, freqüências cardíaca e respiratória, parâmetros hematológicos (eritrócitos, leucócitos, hemograma e hemoglobina), gasometria arterial, traçado eletrocardiográfico e tempo de imobilidade. Os dados foram analisados estatisticamente por ANOVA para medidas repetidas e teste t de Student. O nível de significância foi de α=0,05. Os resultados revelaram que a anestesia geral intravenosa com os protocolos propostos, não desencadeou a ativação do eixo HHA, exceção feita ao Grupo ARTZ. Os valores de ACTH diferiram entre o grupo DRTZ e os demais, sendo que neste houve valores inferiores. Não houve diferença estatística nos valores dos demais parâmetros com exceção da freqüência cardíaca que no grupo RTZ não revelou variações entre as colheitas. O tempo de imobilidade observado no grupo ARTZ foi superior aos demais.
45

Efeitos da associação de dexmedetomidina à ropivacaína 0,75% na anestesia peridural /

Salgado, Paula Fialho Saraiva. January 2008 (has links)
Orientador: Paulo do Nascimento Junior / Banca: Norma Sueli Pinheiro Módolo / Banca: Francisco Ricardo Marques Lobo / Resumo: Os efeitos clínicos e o potencial sinergismo entre a dexmedetomidina e a ropivacaína ainda não foram estudados em pacientes sob anestesia peridural. O objetivo deste estudo foi avaliar as características clínicas da anestesia peridural realizada com ropivacaína associada à dexmedetomidina. Método - Quarenta pacientes, estado físico ASA 1 ou 2, submetidos à correção cirúrgica de hérnia inguinal ou varizes de membros inferiores sob anestesia peridural, participaram deste estudo duplamente encoberto. Os pacientes foram divididos em: Grupo Controle (n = 20), ropivacaína 0,75%, 20 mL (150 mg); e Grupo Dexmedetomidina (n = 20), ropivacaína 0,75%, 20 mL (150 mg), mais dexmedetomidina, 1 mg.kg-1. As seguintes variáveis foram estudadas: tempo de latência do bloqueio sensitivo, nível (dermátomo) máximo de anestesia, tempo de duração dos bloqueios analgésico e motor, intensidade do bloqueio motor, nível de sedação, variáveis hemodinâmicas intrer- e pósoperatórias, analgesia pós-operatória e ocorrência de efeitos colaterais. Resultados - A dexmedetomidina não influenciou o tempo de latência da anestesia nem o nível máximo do bloqueio sensitivo (p > 0,05), mas prolongou o tempo de duração dos bloqueios analgésico e motor (p < 0,05) e da 8 analgesia pós-operatória (p < 0,05), além de determinar bloqueio motor de maior intensidade (p < 0,05). Os valores do índice bispectral foram menores no Grupo Dexmedetomidina (p < 0,05). Não houve diferença na incidência de hipotensão arterial e de bradicardia (p > 0,05). A ocorrência de efeitos colaterais (tremor, náuseas e SpO2 < 90%) foi baixa e semelhante entre os grupos (p > 0,05). Há sinergismo evidente entre a dexmedetomidina e a ropivacaína na anestesia peridural. A dexmedetomidina aumentou o tempo de duração dos bloqueios analgésico e motor, prolongou a analgesia pósoperatória, intensificou... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Clinical effects and the potential synergism between dexmedetomidine and ropivacaine have not been studied in patients undergoing epidural anesthesia. This study aimed to evaluate the clinical characteristics of the epidural anesthesia performed with 0.75% ropivacaine associated with dexmedetomidine. Methods - Forty patients ASA physical status 1 and 2, scheduled for hernia repair or varicose vein surgeries under epidural anesthesia, participated in this double-blinded study. They were assigned for: Control Group (n = 20), 0.75% ropivacaine, 20 mL (150 mg); and Dexmedetomidine Group (n = 20), 0.75% ropivacaine, 20 mL (150 mg), plus dexmedetomidine, 1 mg.kg-1. The following variables were studied: total analgesic block onset time, upper level of analgesia, analgesic and motor block duration time, intensity of motor block, consciousness status, intra and postoperative hemodynamics, postoperative analgesia and incidence of side effects. Results - Epidural dexmedetomidine did not affect onset time nor the upper level of anesthesia (p > 0.05) but prolonged sensory and motor block duration time (p < 0.05) and postoperative analgesia (p < 0.05), and resulted in a more intense motor block, as well (p < 0.05). Values of bispectral index were lower in 10 Dexmedetomidine Group (p < 0.05).There was no difference in incidence of hypotension and bradycardia (p > 0.05). Side effects occurrence (shivering, vomiting and SpO2 < 90%) was low and similar between groups (p > 0.05). There is a clear synergism between epidural dexmedetomidine and ropivacaine. Dexmedetomidine increased sensory and motor block duration time, prolonged postoperative analgesia, enhanced motor block intensity, and did not cause hemodynamic instability. Sedation not associated with hypoxemia is an advantage of the association between ropivacaine and dexmedetomidine in epidural anesthesia. / Mestre
46

Anestesia inalatória e anestesia balanceada e cirurgia toracica experimental em siunos

Pulz, Renato Silvano January 2006 (has links)
O presente trabalho teve por objetivo avaliar a utilização de protocolos de anestesia humana para suínos utilizados como modelo animal com fins de pesquisa médica. Dois grupos de suínos da raça landrace receberam diferentes protocolos anestésicos e foram submetidos a uma toracoscopia lateral. Os dois grupos de suínos receberam como medicação pré-anestésica (MPA), sulfato de atropina , na dose de 0,03 mg . kg-1, por via subcutânea, e midazolam, na dose de 0,5 mg . kg-1, por via intramuscular. O grupo I (anestesia inalatória), trinta minutos após, a anestesia foi induzida com a administração via intravenosa de 10 mg . kg-1 de tiopental sódico, administrado via intravenosa. A manutenção da anestesia foi realizada somente com isoflurano e oxigênio. No grupo II (anestesia balanceada), a anestesia foi induzida por uma associação de fentanil, na dose de 20 mcg . kg-1 , midazolan na dose de 0,5 mg . kg-1, administrados por via intravenosa, seguidos ainda da administração de tiopental sódico (5 mg . kg-1) e pancurônio (0,1 mg . kg- 1), imediatamente após, os suínos foram submetidos à intubação oro-traqueal e conectados ao respirador. A manutenção da anestesia foi realizada pela administração de oxigênio em fluxo constante de seis litros por minuto e isoflurano e pela administração contínua de fentanil (50 µg. kg-1. min. –1) e pancurônio (0,1 mg. kg-1) a cada 20 minutos. O ajuste na dose de infusão do fentanil foi realizado manualmente, pela regulagem do gotejamento. A concentração do isoflurano nos dois grupos variou conforme as variações nas freqüências cardíacas e pressão arterial média. Imediatamente após a indução os animais foram intubados por via orotraqueal e o tubo traqueal foi conectado ao respirador. Os animais foram ventilados com respirador (modelo BIRD®), recebendo uma associação de isoflurano e oxigênio. A freqüência respiratória foi regulada em 16 movimentos por minuto com uma pressão de 20 cm de H2O. Após a preparação pré-operatória, indução anestésica e cateterização da artéria femural, os suínos dos dois grupos foram posicionados em decúbito lateral esquerdo e submetidos à toracoscopia lateral. Foi realizada a exploração torácica, denominada como procedimento diagnóstico, simulando uma situação real. Após a síntese das aberturas o pneumotórax residual foi drenado com auxílio de uma seringa de 10 ml adaptada à válvula de três vias e catéter venoso. Não foi realizado procedimento cirúrgico, além da toracoscopia, para evitar possíveis interferências nos valores observados e que não tenham relação com a anestesia. As colheitas de dados nos dois grupos foram realizadas a cada 15 minutos após a cateterização da artéria femural , durante 60 minutos. Foram anotados e avaliados parâmetros monitorados rotineiramente no controle da anestesia geral. Foram observados aspectos relacionados a função cardiocirculatória, função respiratória, temperatura corporal interna e qualidade da recuperação anestésica. Foram realizados monitoramento da freqüência cardíaca, avaliação eletrocardiográfica, avaliação de oximetria de pulso e hemogasometria arterial. Nos parâmetros relacionados à função respiratória, verificou-se uma redução significativa nos valores médios da pressão parcial de O2 do grupo II. Imediatamente após a indução (T0) a PaO2 em mmHg no grupo I foi de 415,43 ± 47,35. O grupo II apresentou uma PaO2 em mmHg de 332,06 ± 55,81 em T0. Na PaCO2 verificou-se uma redução significativa nos valores médios em todos os tempos avaliados no grupo II. Nos parâmetros relacionados à função cardiocirculatória e temperatura corporal não ocorreram alterações significativas quando comparados os dois grupos, isto é, não sofreram influência dos diferentes protocolos. O parâmetro temperatura corporal interna apresentou uma redução significativa nos dois grupos, relacionada aos diferentes tempos avaliados e a duração da anestesia geral. No grupo II observouse uma recuperação anestésica mais prolongada e com sinais de agitação. Não ocorreram óbitos em nenhum dos grupos. Os dois protocolos comumente utilizados na anestesia humana permitiram a realização da cirurgia torácica experimental em suínos. / The present work had for objective to evaluate the use of anesthesia protocols human being for used swines as animal model with ends of medical research. Two groups of swines of the race Landrace had received different protocols anaesthetics and had been submitted to a lateral thoracoscopy. The two groups of swines had received as daily preanesthetically medication (MPA), atropine sulphate, in the dose of 0,03 mg. kg-1, for via subcutaneous, and Midazolam, in the 0,5 dose of mg. kg-1, for via intramuscular. Group I (inhalatory anesthesia), thirty minutes after, the anesthesia was induced with the administration via intravenous of 10 mg. kg-1 of Thiopental sodium, managed by intravenous. The maintenance of the anesthesia was only carried through with Isoflurane and oxygen. In group II (balanced anesthesia), the anesthesia was induced for a fentanil association, in the dose of 20 mcg. kg-1, Midazolam in the dose of 0,5 mg. kg-1, managed for via intravenous, followed still of the administration of Tiopental (5 mg. kg-1) and Pancuronium (0.1 mg. kg-1), immediately after, the swines had been submitted to the intubation endotracheal and connected to the respirator. The maintenance of the anesthesia was carried through with Isoflurane and oxygen and by the continuous administration of Fentanyl (50μg. kg-1. min.-1) and Pancuronium (0.1 mg. kg-1) to each 20 minutes. Immediately the induction the animals had been after intubated by via endotracheal and the tracheal pipe was connected to a respirator, receiving an association from Isoflurane and oxygen. The respiratory frequency was regulated in 16 movements per minute with a pressure of 20 cm of water. After the preparation pre-operatory, anesthetical induction and catheterization of the femural artery, the swines of the two groups had been located in left lateral decubitus and submitted to the lateral thoracoscopy. The thoracic exploration was carried through, called as disgnostic procedure, simulating a real situation. After the synthesis of the openings pneumotorax residual was drained with aid of a syringe of 10 ml adapted to the valve of three ways and to venous catheter. Surgical procedure was not carried through, beyond the thoracoscopy, to prevent possible interferences in the observed values and that they do not have relation with the anesthesia. The harvests of data in the two groups had been carried through to each 15 minutes after the catheterization of the femural artery, during 60 minutes. They had been written down and evaluated parameters monitored routinely in the control of the general anesthesia. The cardiocirculatory function, respiratory function, internal body temperature and quality of the anesthetically recovery had been observed related aspects. Monitoring of the cardiac frequency, electrocardiographic evaluation, evaluation of oximetry of pulse and arterial gasometry had been carried through. In the parameters related to the respiratory function, was verified a significant reduction in the average values of the partial pressure of O2 of group II Immediately after the induction (T0) the PaO2 in mmHg in group I was of 415,43 ± 47,35. Group II presented a PaO2 in mmHg of 332,06 ± 55,81 in T0. In the PaCO2 of it a significant reduction in the average values in all was verified the times evaluated in group II. In the parameters related to the cardiocirculatory function and body temperature significant alterations had not occurred when comparative the two groups, that is, had not suffered influence from the different protocols. The parameter internal body temperature presented a significant reduction in the two groups, related to the different evaluated times and the duration of the general anesthesia. In group II a drawn out anesthetical recovery and with agitation signals was observed more. Deaths in none of the groups had not occurred. The two protocols usually used in the anesthesia human being had allowed the accomplishment of the experimental thoracic surgery in swines.
47

Estudo comparativo da associação da mepivacaína 2% com epinefrina versus mepivacaína 2% com norepinefrina em seres humanos / Comparative study of the association of mepivacaine 2% with epinephrine versus 2% mepivacaine with norepinephrine in humans.

Viana, Fernando André Campos January 2012 (has links)
VIANA, Fernando André Campos. Estudo comparativo da associação da mepivacaína 2% com epinefrina versus mepivacaína 2% com norepinefrina em seres humanos. 2012. 154 f. Tese (Doutorado em Farmacologia) - Universidade Federal do Ceará. Faculdade de Medicina, Fortaleza, 2012. / Submitted by denise santos (denise.santos@ufc.br) on 2012-11-01T15:29:18Z No. of bitstreams: 1 2012_tese_facviana.pdf: 20241961 bytes, checksum: bcbbd47e505f5438393cf2fa96625a73 (MD5) / Rejected by Erika Fernandes(erikaleitefernandes@gmail.com), reason: on 2012-11-01T15:33:35Z (GMT) / Submitted by denise santos (denise.santos@ufc.br) on 2012-11-01T15:53:19Z No. of bitstreams: 1 2012_tese_facviana.pdf: 20241961 bytes, checksum: bcbbd47e505f5438393cf2fa96625a73 (MD5) / Approved for entry into archive by Erika Fernandes(erikaleitefernandes@gmail.com) on 2012-11-06T13:54:19Z (GMT) No. of bitstreams: 1 2012_tese_facviana.pdf: 20241961 bytes, checksum: bcbbd47e505f5438393cf2fa96625a73 (MD5) / Made available in DSpace on 2012-11-06T13:54:19Z (GMT). No. of bitstreams: 1 2012_tese_facviana.pdf: 20241961 bytes, checksum: bcbbd47e505f5438393cf2fa96625a73 (MD5) Previous issue date: 2012 / Local anesthetics are the most widely drugs used in dental practice. The present study aimed to report the clinical efficacy and safety of therapeutic Mepivacaine 2% with Epinephrine 1:100,000 (MEPI-E) and Mepivacaine 2% with 1:100,000 norepinephrine (MEPI-N) in infiltration anesthesia of upper canine teeth in healthy volunteers. We conducted a clinical trial, prospective, randomized, crossover, triple blind. Thirty patients were randomly and received either 0.6 ml of both anesthetic solution through terminal infiltrative anesthesia in canines. The degree of pain during anesthetic infiltration was made by visual analog scale of pain (VAE). The induction time was measured by measuring electrical test pulp thus the time required for ensuring the locking. The teeth were subjected to electrical tests in periodic cycles and evaluated by 60 minutes in order to verify the effectiveness of anesthesia in dental tissue. The prick test was used to measure the clinical efficacy in soft tissue, at the following sites: buccal gingiva, upper alveolar mucosa, superior labial mucosa and skin. We also observed vestibular-palatal diffusion of the anesthetic. Systolic and diastolic blood pressure, heart rate, oxygen saturation and blood glucose were used as parameters for assessing the systemic therapeutic safety. Established the significance level of 0.05 (5%) were used GraphPad Prism ® and SPSS ®. Were analyzed a total of 60 punctures anesthetic in 30 study volunteers. The MEPI-N group showed lower levels of pain and discomfort during the anesthetic infiltration, which was statistically significant (P = 0.0106) when compared to the MEPI-E. 86.7% when anesthetized with MEPI-N the electric test were negative a time ≤ 30 seconds, against 43.3% of MEPI group-E (P = 0.002). In evaluating the anesthetic efficacy pulp, statistically significant results were observed in intervals of 40, 50 and 60 minutes of evaluation (P = 0.031, P = 0.021, P = 0.039 respectively) showing greater power to the MEPI-N group, in analyzing the effectiveness anesthesia in the upper lip at 30, 35 and 40 minutes (P = 0.031) showed superiority was also attributed to MEPI-N solution. There was no statistical difference between groups in the analysis under the parameters of therapeutic safety. There was no statistical significance in the intergroup analysis in relation to systemic parameters. Intragroup analysis showed that the systolic and diastolic blood pressure, heart rate were significantly lower than baseline for some time in both groups. The mean glucose at 30 minutes was higher and statistically significant at baseline. Results indicate that anesthetic blocks with 2% Mepivacaine with 1:100,000 norepinephrine are able to provide a better standard anesthetic but without result in systemic changes. / Os anestésicos locais são as drogas mais amplamente utilizadas na prática odontológica. O presente estudo teve como objetivo reportar a eficácia clínica e a segurança terapêutica da Mepivacaína 2% com Epinefrina 1:100.000 (MEPI-E) e Mepivacaína 2% com Norepinefrina 1:100.000 (MEPI-N) em infiltração anestésica de dentes caninos superiores em voluntários saudáveis. Realizou-se um estudo do tipo ensaio clínico, prospectivo, randomizado, cruzado, triplo cego. Trinta pacientes foram randomizados e receberam 0,6 mL de ambas as soluções anestésicas, por meio de anestesia terminal infiltrativa, em caninos superiores. Foi avaliado o grau de dor durante a infiltração anestésica por meio da escala visual analógica de dor (EVA). O tempo de indução anestésica foi mensurado pelo teste elétrico pulpar mensurando assim, o tempo necessário para a efetivação do bloqueio. Os dentes foram submetidos a testes elétricos em ciclos periódicos e avaliados por 60 minutos com a finalidade de verificar a eficácia anestésica em tecido dentário. O teste de picada foi utilizado para mensurar a eficácia clínica em tecido mole, nos seguintes sítios: gengiva inserida vestibular, mucosa alveolar superior, mucosa labial superior e pele. Também foi verificada difusão vestíbulo-palatina da solução anestésica. Pressão arterial sistólica e diastólica, frequência cardíaca, saturação de oxigênio e glicemia serviram como parâmetros sistêmicos de avaliação da segurança terapêutica. Estabeleceu-se o nível de significância em 0,05 (5%), foram utilizados os software GraphPad Prism® e o software SPSS®. Foram analisados um total de 60 punções anestésicas em 30 voluntários do estudo. O grupo MEPI-N apresentou menor nível de dor e desconforto durante a infiltração anestésica, com diferença estatisticamente significante (P = 0,0106) quando comparado ao grupo MEPI-E. 86,7% dos pacientes quando anestesiados com MEPI-N se apresentaram negativos ao teste elétrico num tempo ≤ 30 segundos, contra 43,3% do grupo MEPI-E (P = 0,002). Na avaliação da eficácia anestésica pulpar, resultados estatisticamente significantes foram observados nos tempos de 40, 50 e 60 minutos de avaliação (P = 0,031, P = 0,021, P = 0,039 respectivamente) mostrando maior potência ao grupo MEPI-N, na análise da eficácia anestésica em lábio superior nos tempos 30, 35 e 40 minutos (P = 0,031) a superioridade também foi atribuída a solução MEPI-N. Não houve diferença estatística na análise intergrupos sob os parâmetros de segurança terapêutica. Não foi observada significância estatística na análise intergrupo em relação aos parâmetros sistêmicos. Na análise intragrupo observou-se que a pressão arterial sistólica e diastólica, a frequência cardíaca foram significantemente menores que a basal para alguns tempos em ambos os grupos. A média glicêmica aos 30 minutos foi superior e estatisticamente significante ao basal. Resultados apontam que bloqueios anestésicos com Mepivacaína 2% com Norepinefrina 1:100.000 são capazes de conferir um melhor padrão anestésico sem contudo resultar em alterações sistêmicas.
48

Avaliação da reação do paciente durante a administração de anestesia local com seringa convencional ou com controle de punção

Costa, Raquel Campelo Ferreira da January 2012 (has links)
COSTA, Raquel Campelo Ferreira da. Avaliação da reação do paciente durante a administração de anestesia local com seringa convencional ou com controle de punção. 2012. 51 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2012. / Submitted by denise santos (denise.santos@ufc.br) on 2013-02-15T15:46:30Z No. of bitstreams: 1 2012_dis_rcfcosta.pdf: 1221884 bytes, checksum: 0b10d92adf004802842c1c2630616342 (MD5) / Approved for entry into archive by Erika Fernandes(erikaleitefernandes@gmail.com) on 2013-02-18T15:46:34Z (GMT) No. of bitstreams: 1 2012_dis_rcfcosta.pdf: 1221884 bytes, checksum: 0b10d92adf004802842c1c2630616342 (MD5) / Made available in DSpace on 2013-02-18T15:46:34Z (GMT). No. of bitstreams: 1 2012_dis_rcfcosta.pdf: 1221884 bytes, checksum: 0b10d92adf004802842c1c2630616342 (MD5) Previous issue date: 2012 / A anestesia local, utilizada como procedimento de rotina em Odontologia para permitir a realização de um tratamento indolor, por si já apresenta algum grau de dor/desconforto ao paciente, contribuindo para aumentar o medo e a ansiedade no tratamento odontológico em crianças e adultos. Este trabalho teve como objetivo avaliar a reação do paciente durante a anestesia local com seringa convencional e com um dispositivo que controla a punção inicial da agulha. Para tanto a amostra foi composta por 57 crianças, entre nove e 13 anos de idade, de ambos os gêneros, dividida por randomização em dois grupos: G1 e G2, de acordo com o dispositivo utilizado na primeira sessão: seringa convencional ou dispositivo com controle da punção inicial da agulha. A técnica anestésica utilizada foi a anestesia infiltrativa terminal no sulco vestibular da maxila. O mesmo operador, odontopediatra, anestesiou todas as crianças com os dois dispositivos perfazendo um total de 114 sessões anestésicas, sendo cada criança seu próprio controle. Ao final da segunda sessão anestésica solicitou-se que a criança escolhesse o dispositivo de preferência. A avaliação foi realizada utilizando-se os seguintes métodos: Dental Subscale of the Children’s Fear Survey Schedule CFSS-DS, média da frequência de batimentos cardíacos através do uso de um oxímetro de pulso, Escala Comportamental de Frankl, Escala de Ansiedade Facial, Escala Análoga Visual e Escala SOM (Som, Olhos e Movimentos), em quatro momentos do atendimento odontológico, previamente determinados: sala de espera (SE), cadeira odontológica (CO), início da anestesia (IA) e final da anestesia (FA). De acordo com os resultados 72% da amostra demonstrou baixo nível de ansiedade (CFSS-DS) e predominância do comportamento definitivamente positivo (Escala de Frankl) em todos os momentos avaliados (SE, CO, IA e FA) com os dois dispositivos. Não houve diferença estatisticamente significante (P> 0,05) nas médias de dor relatadas pelas crianças entre os dois dispositivos testados. No entanto, houve alta correlação entre dor e ansiedade relatadas pela criança (P< 0,0001) e entre a ansiedade relatada e a dor observada pela escala SOM (P=0,003). Apesar de não ter sido estatisticamente significante, houve maior preferência das crianças pelo dispositivo com controle da punção inicial da agulha. Concluiu-se assim que a utilização do dispositivo com controle da punção inicial da agulha não promoveu diferença na reação entre as crianças do presente estudo em relação à seringa convencional, quanto à dor/desconforto e à ansiedade.
49

Avaliação da reação de crianças submetidas à anestesia odontológica local com seringa convencional e com desenho externo modificado / Evaluation of the reaction of children anesthetized with a traditional syringe and a modified syringe

Carvalho, Fernanda Matias de January 2012 (has links)
CARVALHO, Fernanda Matias de. Avaliação da reação de crianças submetidas à anestesia odontológica local com seringa convencional e com desenho externo modificado. 2012. 53 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2012. / Submitted by denise santos (denise.santos@ufc.br) on 2013-10-24T12:59:27Z No. of bitstreams: 1 2012_dis_fmcarvalho.pdf: 1213304 bytes, checksum: 80bfb30aef01704f8174b25fee9d1e98 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2013-10-24T13:00:01Z (GMT) No. of bitstreams: 1 2012_dis_fmcarvalho.pdf: 1213304 bytes, checksum: 80bfb30aef01704f8174b25fee9d1e98 (MD5) / Made available in DSpace on 2013-10-24T13:00:01Z (GMT). No. of bitstreams: 1 2012_dis_fmcarvalho.pdf: 1213304 bytes, checksum: 80bfb30aef01704f8174b25fee9d1e98 (MD5) Previous issue date: 2012 / Despite advances in Odontology, fear and anxiety regarding dentistry still affect a large number of people who, because of their fears, fail to seek treatment; this can result in low levels of oral health. The physical appearance of the instruments used by dentists seems to be a major cause of such fear and anxiety with regard to dentistry. The anesthetic syringe is the instrument that causes the strongest feelings of fear. So, the prevention of dental anxiety and patients fear should be one of the dentist’s highest priorities, this study aims to compare the reactions shown when children were anesthetized with a modified device and when they were anesthetized with a traditional syringe, and examine the results to see if a change in the external design of the anesthetic syringe can influence the levels of anxiety, fear and pain of patients. Sixty-four children aged 4-10 years were randomly assigned into two groups according to the device to be used in the first session of anesthesia. G1 (Traditional Syringe) and G2 (Modified syringe). Participants underwent two sessions and each patient was anesthetized with both devices. A single researcher performed anesthetic procedures, which were videotaped and the procedure consisted of infiltrative anesthesia in the posterior area of the maxilla. Due to the multidimensional nature of fear, anxiety and pain, a combination of tests was used to access them: Child Fear Survey Schedule - Dental Subscale - CFSS-DS, Facial Anxiety Scale-FAS, heart rate, the SEM scale Sound, Eyes and Motor, the Visual Analogue Scale (VAS) and the Frankl scale. These tests were applied in predefined situations as the waiting room (WR), the dental chair (DC), during the onset of anesthesia (OA) and end of anesthesia (EA). After the second session of anesthesia, children chose the device that they preferred. The results showed that most 78% children were classified as having a low level of anxiety (CFSS-DS). No significant difference was observed when comparing the traditional and modified devices. The syringe with a change in design was preferred by (57.8%) of the children. The anxious children reported more pain than non-anxious (p = 0.001) and their emotional state varied in different situations: WR, DC, OA and EA. (P <0.05). Thus, it was concluded that the appearance of the syringe is important, but not essential in order to control the anxiety, fear and pain which children suffer when undergoing dental anesthesia. / Apesar dos avanços da ciência, o medo e ansiedade, por razões odontológicas, ainda acometem uma grande quantidade de pessoas, comprometendo a procura por tratamento e resultando, ocasionalmente, em baixos níveis de saúde oral. A aparência física dos instrumentos parece ser um dos principais causadores de medo e ansiedade no meio odontológico, e a seringa anestésica é o instrumental que mais desencadeia estes sentimentos. Assim, diminuir a ansiedade e o medo do tratamento odontológico deveria ser uma das prioridades do cirurgião-dentista. Para tanto, a presente dissertação teve por objetivo comparar as reações apresentadas por crianças que foram anestesiadas com um dispositivo em formato lúdico e com uma seringa tradicional, com a finalidade de analisar se uma mudança no desenho externo da seringa anestésica seria capaz de influenciar os níveis de ansiedade, medo e dor dos pacientes. Sessenta e quatro crianças, com idade ente 4-10 anos, foram distribuídas aleatoriamente em dois grupos, de acordo com o dispositivo a ser utilizado na primeira sessão anestésica. G1 (Convencional) e G2 (Design modificado). Os participantes submeteram-se a duas sessões anestésicas, e cada paciente foi anestesiado com ambos dispositivos. Um único pesquisador, odontopediatra, realizou os procedimentos anestésicos que foram filmados e consistiram de anestesias terminais infiltrativas, na região posterior da maxila. Devido ao caráter multidimensional do medo, ansiedade e dor, uma combinação de testes foi utilizada para avaliá-los, como: O teste de medo da criança (Child Fear Survey Schedule – Dental Subscale - CFSS-DS), escala de ansiedade facial (Facial Anxiety Scale- FAS), frequência cardíaca, escala som, olhos e movimento (Sound, Eyes and Motor-SEM), escala visual analóga – Visual Analogue Scale (VAS) e escala Frankl. As escalas foram aplicadas em momentos predeterminados, como: sala de espera (SE), cadeira odontológica (CO), início da anestesia (IA) e final da anestesia (FA). Após a segunda sessão anestésica, as crianças escolheram o dispositivo que mais as agradou. Os resultados mostraram que 78% da amostra foi classificada como pouco ansiosa (CFSS-DS). Nenhuma diferença estatisticamente significante pôde ser observada nas diferentes escalas, ao comparar o dispositivo tradicional com o modificado. A seringa com mudança no design foi a preferida por 57,8% das crianças. As crianças ansiosas relataram mais dor que as não ansiosas (p=0,001) e o estado emocional variou nas diferentes situações: SE, CO, IA e FA. (p<0,05). Assim, concluiu-se que a aparência da seringa é importante, mas não é fundamental no controle da ansiedade, medo e dor de crianças submetidas à anestesia odontológica.
50

Avaliação comparativa em relação a dor de crianças submetidas à anestesia odontológica com e sem vibraçã / Comparative analysis regarding the pain of children under the dental anesthesia with and without vibration

Melo, Emanuelle Albuquerque Carvalho January 2014 (has links)
MELO, Emanuelle Albuquerque Carvalho. Avaliação comparativa em relação a dor de crianças submetidas à anestesia odontológica com e sem vibração. 2014. 67 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2014. / Submitted by denise santos (denise.santos@ufc.br) on 2014-02-14T16:23:48Z No. of bitstreams: 1 2014_dis_eacmelo.pdf: 2024084 bytes, checksum: 4d85ed308c4ae3a8de26a93820200f4b (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2014-02-14T16:24:59Z (GMT) No. of bitstreams: 1 2014_dis_eacmelo.pdf: 2024084 bytes, checksum: 4d85ed308c4ae3a8de26a93820200f4b (MD5) / Made available in DSpace on 2014-02-14T16:24:59Z (GMT). No. of bitstreams: 1 2014_dis_eacmelo.pdf: 2024084 bytes, checksum: 4d85ed308c4ae3a8de26a93820200f4b (MD5) Previous issue date: 2014 / The fear and anxiety during dental treatments are often related to pain regarding local dental anesthetic procedures. As there are many studies about the effect of vibration on pain analgesia, this thesis aimed to compare whether children anesthetized with a dental anesthetic device that produced micro-vibrations during the anesthetic procedure would behave differently when compared to the regular procedure. Thirty children, aged between 7 and 12 years underwent two sessions of local dental anesthesia each, with and without the vibration device. A single researcher, pediatric dentist, managed the anesthetic procedures that consisted of maxillary infiltration anesthesia and which were recorded on video. Due to the multidimensional nature of fear, anxiety and pain, multiple tests were used to evaluate them, such as Child Fear Survey Schedule – Dental Subscale – CFSS-DS, Facial Anxiety Scale – FAS , the SEM Scale Sound, Eyes and Motor, the Visual Analogue Scale (VAS) and the Frankl Scale. The scales were applied twice, before and after anesthesia. After the second anesthetic session, the preference of the children regarding the use or not of vibration was assessed and it was found that 90% of children preferred anesthesia using vibration. There was a statistically significant difference considering the Visual Analogue Scale (VAS) in the comparison of means (p = 0,04) considering a significance level of 5%. As a result, we concluded that the use of vibration seemed to result in a positive influence on the perception of the children regarding the anesthetic procedure, as almost the totality opted by the device with vibration, which lead us to the conclusion that the use of vibration resulted in a less painful local dental anesthesia. / O medo e a ansiedade durante os tratamentos odontológicos estão na maioria das vezes relacionados à dor do procedimento da anestesia local odontológica. Considerando que existem muitos estudos sobre a atuação da vibração na analgesia, esta dissertação teve por objetivo comparar as reações apresentadas por crianças ao serem anestesiadas com um dispositivo de anestesia local odontológica que produzia microvibrações durante o procedimento anestésico. Trinta crianças, sendo 15 do sexo feminino e 15 do sexo masculino, com idade entre sete e 12 anos submeteram-se a duas sessões anestésicas, e cada paciente recebeu dois tipos de anestesia: com e sem vibração. Um só pesquisador, odontopediatra, realizou os procedimentos anestésicos, que foram filmados e consistiram de anestesias terminais infiltrativas, na região posterior da maxila. Em razão do caráter multidimensional do medo, ansiedade e dor, utilizou-se uma combinação de testes avaliá-los, como: O Teste do Medo da Criança (Child Fear Survey Schedule – Dental Subscale – CFSS-DS), Escala de Ansiedade Facial (Facial Anxiety Scale – FAS), Escala Som, Olhos e Movimento (Sound, Eyes and Motor – SEM), Escala Visual Analóga – Visual Analogue Scale (VAS) e Escala Frankl. Aplicou-se as escalas em momentos prederteminados, os quais ocorreram antes e após o procedimento anestésico. Após a segunda sessão anestésica, buscou-se saber a preferência das crianças quanto ao uso ou não de vibração e verificou-se que 90% das crianças preferiram a anestesia utilizando-se vibração. Houve diferença estatisticamente significante na Escala Visual Análoga – Visual Analogue Scale (VAS) na comparação das médias (p = 0,04) para um critério de seleção a um nível de significância de 5%. Dessa forma, conclui-se que o uso da vibração pareceu exercer influência positiva sobre a percepção das crianças durante o procedimento de anestesia local, pois a maioria dos participantes da pesquisa optou pelo dispositivo com emprego da vibração, atrelando ao fato de que foi verificado que a anestesia local com vibração provoca menos dor, segundo a diferença estatisticamente significante da Escala Visual Análoga.

Page generated in 0.0792 seconds