• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 405
  • 177
  • 31
  • 2
  • 1
  • Tagged with
  • 740
  • 740
  • 526
  • 109
  • 108
  • 94
  • 89
  • 88
  • 76
  • 70
  • 64
  • 64
  • 64
  • 61
  • 59
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Energianvändning och termisk tröghet i småhus med massivträkonstruktioner

Enarsson, Johanna January 2023 (has links)
I Sverige står byggbranschen för en energianvändning som motsvarar omkring 40% av den totala energianvändningen. Av en byggnads energianvändning sker den största andelen under driftsfasen. För att förbättra byggnaders prestanda har fokus legat på att erhålla låga U-värden för klimatskalet, framför allt genom ökad isolering. Ett problem som finns är dock att byggnaders förväntade energiprestanda inte alltid stämmer överens med den uppmätta prestandan. En faktor som skulle kunna minska en byggnads energibehov är värmetrögheten. Vid framtagning av en byggnads förväntade energibehov ingår värmetrögheten i form av en tidskonstant, som beskriver byggnaders förmåga att klara av tillfälliga temperaturförändringar utomhus utan att inomhustemperaturen ändras avsevärt. Det har dock visat sig vara svår att bestämma värmetrögheten samt dess påverkan på energianvändningen. Allt eftersom nya tekniker utvecklas med nya typer av konstruktioner som frångår det traditionella är det av intresse att analysera hur en byggnads förväntade energibehov enligt de metoder som används idag stämmer överens med den uppmätta energianvändningen, samt om värmetrögheten kan vara en faktor som påverkar den uppmätta energianvändningen. Syftet med detta arbete har varit att analysera energianvändningen för byggnader med icke-traditionella väggstommar av massivträ, för att jämföra den förväntade energianvändningen mot den uppmätta med två av de metoder som finns idag. För att göra en jämförelse mellan teoretisk och uppmätt energianvändning har en fallstudie genomförts där två villor med samma typ av väggstommar har analyserats. Villornas förväntade energianvändning har tagits fram genom beräkningar samt simuleringsprogram. Att använda två olika tillvägagångssätt har givit möjlighet att jämföra olika verktyg för att bestämma en byggnads förväntade energianvändning. Resultatet från studien har som tidigare studier visat på en skillnad mellan förväntad och uppmätt energianvändning, där det visat sig vara en svårighet att applicera värmetrögheten i energiberäkningar med de metoder som används idag. För att bestämma värmetrögheten för olika dimensioner av det studerade väggelementet har ett experiment genomförts med syfte att mäta tidskonstanten. Experimentet har utförts i en klimatkammare där lådor med väggelementen som samtliga omslutande delar har testats. Resultatet har visat på att det faktiska värdet för tidskonstanten frångår de förväntade värden som tagits fram genom beräkningsmetoder, där värmetrögheten för det väggelement som utgör stommen för de studerade villorna är högre än vad som används i beräkningar idag. Detta har givit indikationer på att de metoder som används idag inte är tillräckligt anpassade för nya typer av väggstommar, vilket skulle kunna bidra till att det förväntade energibehovet inte stämmer överens med det faktiska. Studien har visat på en alternativ metod att bestämma värmetrögheten för ett väggelement, samt givit indikationer på att fler studier inom ämnet skulle behöva genomföras för att på ett bättre sätt koppla samt ta hänsyn till värmetrögheten i energiberäkningar. / The energy use in the construction industry's in Sweden corresponds to about 40% of the total energy consumption. The largest share of a building's energy use takes place during the operational phase. In order to improve the performance of buildings the focus has been on obtaining low U-values for the building envelope, primarily through increased insulation. However, there is a problem that the expected energy performance of buildings does not always correspond to the measured performance. A factor that could reduce a building's energy needs is thermal inertia. When producing a building's expected energy needs, the thermal inertia is included in the form of a time constant, which describes the ability of buildings to cope with temporary temperature changes outside without the indoor temperature changing significantly. However, it has proven to be difficult to determine thermal inertia and its impact on energy use. As new technologies are developed with new types of constructions that depart from the traditional, it is of interest to analyze how a building's expected energy needs according to the methods used today match the measured energy use, and whether thermal inertia can be a factor that affects the measured energy use. The purpose of this work has been to analyze the energy use of buildings with non-traditional solid wood wall frames, to compare the expected energy use against the measured, using two of the methods available today. The comparison between theoretical and measured energy use  has been done through a case study, where two villas with the same type of wall frames have been analysed. The villas' expected energy use has been developed through calculations and simulation programs. Using two different approaches has provided the opportunity to compare different tools to determine a building's expected energy use. The results of the study have, like previous studies, shown a difference between expected and measured energy use, where it has proven to be a difficulty to apply thermal inertia in energy calculations with the methods used today. In order to determine the thermal inertia for different dimensions of the studied wall element, an experiment has been carried out with the aim of measuring the time constant. The experiment has been carried out in a climate chamber where boxes with the wall elements as all enclosing parts have been tested. The result has shown that the actual value of the time constant deviates from the expected values obtained through calculation methods, where the thermal inertia of the wall element that forms the frame of the studied villas is higher than what is used in calculations today. The study has shown an alternative method for determining the thermal inertia of a wall element, as well as giving indications that more studies in the subject would need to be done in order to in a better way connect and take thermal inertia into account in energy calculations.
252

Animate form through low tech wood construction

Bölin, Eric January 2018 (has links)
How can we build small scale dynamic shapes with what we have? This project will present a method to build your own free form wooden structure without relying on high-tech computer programs or custom made parts from expensive factories.
253

Nybyggnation av en fastighet till temporära bostäder i ett ljudutsatt område / New construction on a property for temporary housing in a sound polluted area

Birger, Anna, Holmstedter, Christian January 2019 (has links)
I takt med en ökad globalisering och expandering av de större städerna så har det avgått allt fler flyg till och från Sverige, vägar har byggts ut och allt fler platser som är exponerade för trafikbuller har tillkommit. Detta är ett stort problem då buller kan ha förödande effekter på människors hälsa. Som svar på detta problem har bl.a. BBR uppfört krav på fastigheter beroende på dess användningstyp. Kravet är restriktioner gällande bullernivåer vid en byggnads yttre fasad där permanenta bostäder har det högsta kravet på en låg bullernivå. Vid de allt mer ljudexponerade platserna så nekas bygglov regelbundet då de potentiella fastigheterna inte möter detta krav. Då det rör sig mer folk i Sverige, t.ex. via affärsresor, både inrikes och utrikes, så skapas en efterfrågan på temporära bostäder där människor kan vistas tillfälligt upp till 6 månader. På senare tid har allt fler projekt startats upp där man utnyttjar läget av bullerutsatta platser för att etablera verksamheter tillägnat åt temporära bostäder. Detta eftersom temporära bostäder inte ställer samma höga krav på bullernivåer som permanenta bostäder gör. Examensarbetet undersöker de problem och förutsättningar som finns vid en bullerutsatt plats för att senare gestalta ett förslag på ett temporärt boende som håller de gällande krav och bestämmelser som finns vid uppförandet av en sådan byggnad i det aktuella läget. Arbetet avgränsades till Stockholms län och de arkitektoniska samt vissa byggtekniska detaljer projekterades fram. Inga egna bullermätningar gjordes då mätnoggrannheten på de egna verktygen var låg. Utifrån de förutsättningar och kunskaper som gavs från platsanalysen och den teoretiska referensramen så projekterades ett gestaltningsförslag på ett lägenhetshotell fram på en fastighet precis intill Arlanda flygplats där bullernivåerna överskred BBR:s riktlinjer gällande bullernivåer vid permanenta boendens fasad. Resultatet blev en tung betongkonstruktion med tjocka partier isolering samt vegetation på fasad och tak. Byggnaden utnyttjade det aktuella läget för fastigheten och placerades vid kringliggande vegetation som har ett naturligt bullerreducerande skydd. Examensarbetet lämnade dock kvar frågor som förblev obesvarade. Stod byggnaden emot fastighetsägarens höga krav för ljusinsläpp och design? Hur mycket ljudreducerande agerade den omkringliggande vegetationen? Var det mer lämpligt att bygga på bredden snarare än höjden? Detta lämnar rum för vidare undersökning kring problematiken eventuella och lösningar vid nybyggnation i bullriga miljöer. / With the increased globalization and expansion of larger cities, we’ve seen an increase in flight traffic around the airports in Sweden. At the same time, cities are getting more populated which leads to more roads that are being built to strengthen the communications between the cities. A consequence of this expansion is that more areas are being affected by sound pollution. This is a huge problem as sound pollution may have devastating consequences on the health of people being exposed by it. To counteract the exposure of sound pollution, Boverket (the national Board of Housing), has created specific regulations on real estate’s regarding the accepted levels of sound exposure for buildings. The allowed level of sound exposure are stricter to buildings that are meant to be permanently inhabited as the inhabitants run greater risk of health issues the longer they are exposed by it. As there are more people traveling across Sweden on e.g. business trips, there has been an increase in demand of temporary housing where people are allowed stay for up to 6 months. Just recently, plenty of new projects are taking advantage over the set regulations by the National Board of Housing because the regulations for sound exposure are lower on temporary housing. This thesis will investigate the possibilities regarding projecting a building meant for temporary housing in a sound polluted area. The project is limited to the Stockholm county and focus mainly on the architectural point of view in projecting a building. A projected architectural proposal of an apartment hotel on a property right next to Arlanda airport was made from the information that was provided by the site analysis and the theoretical framework. The property was located in an area where the sound exposure was above the regulations of maximum sound pollution by the facade of building meant for permanent housing. The result was a heavy constructed concrete building with thick layers of insulation and vegetation on the outside walls and roofs. The building was placed in an area where it was surrounded natural vegetation to improve the reduction of sound pollution. The thesis left a few unanswered questions however: Did the projected building meet the requirements of the property owners regarding architecture and lighting? By how much does the surrounding vegetation actually reduce sound pollution? Would it be more efficient to increase the width of the building rather than the height? These questions leaves room for further studies regarding the issues and how to solve them when projecting buildings in a highly sound polluted area.
254

Seismic Performance of Unreinforced Masonry Walls Retrofitted with Post-tensioning Tendons

Lazzarini, Daniel Louis 01 June 2009 (has links) (PDF)
Unreinforced masonry (URM) structures have historically been regarded as structurally unsound in response to seismic events. The tendency for URM walls to collapse out-of-plane in a brittle manner is continually cause for concern. Retrofit of these walls is necessary in order to prevent severe damage and injury to occupants. This paper is concerned with the retrofit of unreinforced masonry (URM) walls in response to out-of-plane loading. A retrofit design was developed and verified through structural testing. The selected retrofit technique incorporates vertical coring of URM walls to allow for the insertion of a single post-tensioning (PT) tendon. Tendons are spaced at a regular interval and anchored at the top of the wall parapet and at the lower diaphragm level. Tensioning of the tendons imparts a compressive stress to the wall that effectively increases the wall cracking moment strength, ultimate moment strength and displacement capacity. Additionally, the insertion of PT tendons allows the wall to behave in a ductile manner in response to out-of-plane ground motion. Extensive research was conducted in order to accurately portray the material properties and construction methods of unreinforced masonry walls in San Luis Obispo, California. Various mortar mix designs were generated and tested so that a mix design could be selected to best reflect the target URM structures. Seismic parameters were generated to reflect a URM structure in San Luis Obispo. An unreinforced masonry wall was constructed by a professional mason using the established mortar mix proportions and salvaged bricks from the 1920 era. Having a pin-pin unsupported height of 11 feet, the wall constructed for testing was reflective of the configuration of URM walls in many downtown San Luis Obispo structures. The wall was loaded in the out-of-plane direction by 4 equal point loads mimicking a uniformly distributed load. The testing program consisted of cycling the wall through target internal moments and target displacements. It was verified through testing that post-tensioning tendons can be successfully introduced in URM walls to resist out-of-plane bending. Testing showed that the addition of PT tendons significantly increased the wall’s cracking moment capacity, giving it the elastic strength to resist twice the forces imposed by the design-level ground motion. PT tendons also increased the nominal strength of the wall, allowing the wall to achieve large displacements without collapse. It was also found that PT tendons provided a restoring force to the wall returning it to almost no residual displacement after each displacement cycle. Thus, the URM wall retrofitted with PT tendons demonstrated significant integrity as a structural system, providing for improved strength and ductility with no residual displacement.
255

Developing Dendrifrom Facades Using Flow Nets as a Design Aid

Houston, Jonas H. 01 December 2011 (has links) (PDF)
This thesis highlights a method of arriving at form that minimizes the need for high end technology and complex mathematical models, yet has structural principles of load flow at the highlighted methods core. Similar to how graphical statics assisted earlier architects and engineers to arrive at form by relating form and forces, this thesis suggests a method of form finding that relates the flow of stresses within solid masses to possible load-bearing façades. Looking to nature, where an abundance of efficient structural solutions can be found, this thesis focuses on a tree-like structural form called the dendriform. In doing so, this thesis explores the idea that through an understanding of typical load flow patterns and the removal of minimally stressed material of the solid body, dendriforms can be revealed that qualitatively exemplify load flow yet maintain an architectural aesthetic.
256

En kvantitativ utvärdering av ett lågenergihus i subarktiskt klimat : – gällande energianvändning, inomhusklimat och fuktvandring

Gustavsson, Jonathan January 2020 (has links)
Low-energy houses are a good concept for reducing energy use during the building's use. Especially when studies have shown economic profitability in buildings that meet the requirements for the definition of low-energy houses - that the energy performance is at least 25% better than the building standard from the Swedish National Board of Housing, Building and Planning. The investment cost of houses with low energy performance is higher, but the economic profitability is achieved under the reduced operating costs. However, it can be difficult to ensure the quality of all new construction techniques and installations, which can lead to worse energy performance than projected values ​​show. To maintain economic profitability, buildings must be maintained throughout their lifetime without unexpected costs to a greater extent. Moisture damage, which can seriously damage the construction and add odors that lead to a bad indoor climate, has over time caused great costs in our buildings. Poor indoor climate can have consequences that create or strengthen mental and physical symptoms. This is something we want to counteract with knowledge of how the indoor climate is in use. In Sweden, most evaluations of low-energy houses have treated houses in the southern parts of the country. There are large climate differences across the country. Construction techniques that are proven to work in the south, do not always perform as well in the north. In the northernmost parts, there is a subarctic climate - where the average temperature exceeds  for a maximum of three months a year. The purpose of this study is to evaluate a low-energy house in a subarctic climate and make a contribution to increased knowledge regarding the type of building in this climate. To achieve the project's goal, to map the house's performance in terms of energy use, indoor climate and moisture migration, literature and case studies have been carried out. These studies are aimed at one of four apartment buildings that are located in the northernmost parts of Sweden and have been built according to a concept with environmental thinking in focus. The evaluation is based on previously performed field measurements during 2016/2017 as well as a survey of residents in the case study building and its three adjacent almost identical houses. The energy performance in operation turns out to exceed the projected value. The house is designed with very small margins for the construction year's low-energy house requirements. Requirements from the Swedish National Board of Housing, Building and Planning are achieved, but the specific energy use of buildings exceeds the low-energy house requirement and achieves energy class C according to the Lågans definition. If the house's energy performance is set against today's stricter requirements and with the new calculation method with primary energy, it will not be able to achieve class C. Possible causes can be heat losses related to the house's supply air system and storage of domestic hot water. To evaluate the indoor climate, the thermal climate, humidity and carbon dioxide content of the house are studied. This is weighed together with the survey about the living experience of residents. The case study building is considered to perform well regarding the indoor climate, as no critical values ​​have been identified according to the field measurement and very little dissatisfaction from the survey study. The moisture content of the house's wall construction exceeds the critical moisture condition several times in all facades during parts of the year. There is no risk of microbial growth as this is during very short periods or periods where the corresponding temperature in the wall is too low. However, inactive measurement periods during the holiday season in the summer creates uncertainties. There may be value in continued control that runs continuously over the warmer period of the year. The general conclusion from the evaluation of the low-energy house is positive. A good concept with the environment in focus that has also tested modern technical solutions in the northern parts of the country.
257

Utilization of Rubber and Plastic Waste as  A Partial Replacement of Aggregate for  Improved Sound Insulation

Chabuk, Nooralhuda January 2022 (has links)
Globally, billions of tons of rubber and plastic waste are produced annually, and because these wastes degrade so slowly (about 450 years for plastic bottles and 80 years for tire rubbers), they are extremely difficult to dispose of. As a result, utilizing these wastes directly in building materials can significantly reduce the environmental load while also increasing the sustainability of the building material. This study compares the roles and effects of using recycled plastic and rubber as aggregates on the properties as well as the performance of concrete. This research focuses on sound insulation properties in particular. Each artificial polymer material of rubber and plastic has a special structure but consists of the same essential components. Plastic and rubber wastes, replacing fine/coarse aggregates are determined by their sort, size, replacement content, and shape. Plastic-based aggregates generally reduce the concrete's workability, but the impact of rubber-based aggregates is mostly influenced by their size and replacement amount. The main objective of this study is to review the evaluation of the sound insulating properties of concrete containing particles of plastic and rubber wastes based on their size, replacement amount, shape, and other factors. For the recycled PET, the results showed that the best percentage of recycled PET fibers mixed with ordinary concrete was in the range of 0.5 – 1.5% compared with other percentages. Low values in the range of 0.5 - 2%, especially 0.5%, of recycled PET mixed with concrete demonstrated the best value in terms of compressive strength compared with ordinary concrete. For the recycled rubber aggregate, the improved sound loss transmission for coarse crumb rubber was higher than the sound loss when using the same percentage of fine crumb. This could belong to that the coarse aggregate caused the voids to appear and increased the porosity in the system compared with the fine aggregate. When these aggregates were included the sound absorption can be improved drastically. The compressive strength of the samples containing fine crumbs of rubber was decreased compared to the control concrete sample without added rubber.   Many previous studies found a clear drop in compressive strength when using a fine rubber aggregate compared with coarse rubber aggregate. Generally, when adding a higher percentage of rubber, the sound absorption coefficient increased, while the compressive strength decreased.  Many researchers found that the thermal insulation increased when adding higher percentages of plastic and rubber waste to concrete. The degree of thermal insulation improvement for mixing concrete with plastic and rubber is also determined by the shape of the pieces. The density of concrete decreased as the percentage of plastic and rubber particles in the mixture increased.
258

LJUDMILJÖN I MILJONPROGRAMMET : En fallstudie om hur renovering och förtätning kan skapa en bättre inre- och yttre miljö

Partelow, Alexandra, Andersson, Frida January 2023 (has links)
Buller har utifrån forskning visat på en stor påverkan av människors hälsa och är dessutom den miljöstörning flest människor utsätts för i Sverige. Vidare kan buller ge upphov till problem med hjärt-och kärlsjukdomar samt bidra till sömn- och koncentrationssvårigheter. Trafikbuller är den vanligaste ljudkällan och med utgångspunkt i kartläggningar för vägtrafikbuller, anses boendemiljöer tillhörandetvå miljoner svenskar inte uppnå riktlinjer för buller i utomhusmiljön. Ljudkrav har funnits sedan slutetpå 1940-talet under olika namn och regelsamlingar. Byggnadsstadga, BABS 60 och Svensk byggnorm67 var de regelverk som tillämpades under miljonprogrammet, då en miljon bostäder uppfördes underår 1965 och 1974. Miljonprogrammets fastigheter är nu över 50 år och byggnadernas tekniska livslängdbörjar närma sig slutet där ungefär 165 000 av miljonprogrammets bostäder behöver upprustas. Isamband med en renovering är det aktuellt att beakta ljudisoleringen för att åstadkomma byggnadersom uppfyller dagens ljudkrav. Kvartersstrukturen för miljonprogrammets flerbostadshus är ofta öppenmed stora avstånd mellan huskropparna samt outnyttjade ytor vilka kan locka till förtätning. Syftet medexamensarbetet är därav att utreda akustiska utmaningar kopplat till arkitektur, byggteknik, gårdsmiljöoch omgivning för att kunna skapa en bättre ljudmiljö vid en renovering och förtätning i ettbostadsområde från miljonprogrammet. Studien innefattar en litteraturstudie inom områdena arkitektur, akustik, ljudkrav, renovering ochförtätning för att skapa en teoretisk grund. Vidare grundar sig studien i en fallstudie för ettmiljonprogramsområde i Malmö, bestående av platsanalyser utifrån metoderna Serial vision, Lynch ochGehl samt ljudanalyser i form av ljudmätningar och subjektiva upplevelser av ljudmiljön.Konceptutvecklingen baseras på teori, bullerkartläggning samt platsens förutsättningar vilketvidareutvecklas genom att ta hänsyn till platsanalysernas resultat. Två av fallstudiensbyggnadskonstruktioner undersöktes för att genomföra simuleringar och beräkningar att jämföra mednuvarande ljudkrav och riktvärden. Utifrån teori, fallstudie och beräkningsresultat prövades ochutvärderades olika åtgärder i syfte att uppfylla dagens ljudkrav och skapa en bättre inre- och yttreljudmiljö. Studiens resultat visar på att lägenhetsavskiljande innerväggar samt bjälklag i betong uppfyller ljudklassC för ljudnivåskillnad enligt nuvarande ljudkrav, däremot uppfyller inte bjälklagen kravvärdena förstegljudsnivå. Vidare uppfyller bostäderna kravställningen för ljudisolering mot yttre ljudkällor utifrånstudiens ljudmätningar. Med Malmö stads bullerkartläggning som utgångspunkt överstiger denberäknade inomhusljudnivån kravvärdet för tre av nio fall. Ett tidstypiskt bostadsområde, med öppenbebyggelsestruktur och omgivande trafikleder uppfyller inte riktvärdena gällande ekvivalent ljudnivåvid uteplatser utifrån utförda ljudmätningar. Däremot uppfylls riktvärdet för den maximala ljudnivånvid uteplatser. Slutligen uppfyller även fasadmätningarna riktvärdet vid fasad. Åtgärdsförslagen i form av stegljudsdämpande skikt förbättrar stegljudsnivån så att ljudklass C eller Buppnås. Förtätningsförslaget medför att ljudnivån inom området generellt minskar med 10 dB. Befintligbebyggelse skärmas av genom att ny bebyggelse placeras parallellt med trafikleden, uppförda i tvåförskjutna rader för att minska bullerspridning in till gårdarna. Även fönsterfria gavlar nyttjas därtillbyggnader ansluter mot den befintliga bebyggelsen och skapar en effektiv bulleravskärmning. För attskapa en ljuddämpad sida för samtliga tillbyggnader i förtätningsförslaget krävs ytterliga åtgärder i formav till exempel akustikskärmar. Utifrån studiens bullerkartläggning medför förtätningen att de befintligauteplatserna uppfyller riktvärdena för ekvivalent ljudnivå. Eftersom ljudnivån inom området minskarantas ljudmiljön även upplevas betydligt mer behaglig. De sänkta ljudnivåerna vid fasaderna skapar ävenstörre marginaler till kravställningen gällande ljudisolering mot yttre ljudkällor. Utöver förbättradeakustiska aspekter medför förtätningen förändrade gårdsbildningar där platsens positiva kvaliteter värnatsom.
259

Erfarenhetsåterföring inom den projektbaserade byggbranschen : En intervjustudie av två besläktade projekt

Lundin, Ludvig January 2023 (has links)
Byggbranschen idag har stora utmaningar med slöseri av resurser och återkommande fel under produktionsfasen nämns som ett allvarligt problem. Genom att utveckla entreprenörers erfarenhetsåterföring kan den projektbaserade branschen på sikt minska det totala svinnet. Denna studie syftar till att undersöka de aktiviteter som en svensk entreprenör genomför under två projekt. Målet är att presentera rekommendationer om hur projektbaserade entreprenörer inom byggbranschen bör lägga upp processen för genomförandet av erfarenhetsåterföring. Detta ska svaras på genom två frågeställningar: 1.     Hur har erfarenhetsåterföringen gått till i den undersökta intervjustudien av två besläktade projekt? 2.     Vad karaktäriserar en god erfarenhetsåterföring inom en projektbaserad organisation? En litteraturstudie visade på kunskap och organisatoriskt lärande som de bakomliggande begreppen som styr erfarenhetsåterföringen. Undersökningen gjordes sedan som en intervjustudie baserad på intervjuer av tjänstepersoner som är involverade i det dagliga arbetet på byggarbetsplatsen. De fick berätta om det arbetet som genomförs för att ta vara på de kunskaper som produceras under projekten och föra vidare det i organisationen. De aktiviteter som identifierades under intervjuerna analyserades genom teoretisk tematisk analys. Olika delar av organisatoriskt lärande; förvärv av kunskap, distribution av information, tolkning av information och organisatoriskt minne; låg som grund för tematiseringen av de olika aktiviteterna. Totalt identifierades under intervjuerna tolv aktiviteter som ansågs ha en påverkan på projektens erfarenhetsåterföring. Tre tematiserades som förvärv av kunskap, en som distribution av information, tre som tolkning av information och fem som organisatoriskt minne. Med hjälp av en identifierad definition av erfarenhetsåterföring kunde sedan antalet aktiviteter som faktiskt utgör erfarenhetsåterföring i de aktuella projekten begränsas till tio stycken. Dessa aktiviteter bidrog i olika omfattning positivt till organisationens framtida resultat. För att klara av att genomföra en effektiv erfarenhetsåterföring i byggbranschen kunde denna studie konstatera att mängden dokumentation och information som förs vidare från ett enskilt projekt kraftigt behöver begränsas. Om lärdomar och kunskaper på ett användbart sätt ska gå att förmedla från ett projekt vidare i organisationen är det vara nödvändigt att begränsa informationsflödet. Genom att fokusera projektets lärande på en enstaka eller ett fåtal pilotundersökningar går det att skapa bättre strukturer och mer genomtänkta metoder för analyser och tolkningar. Med detta tillvägagångssätt kommer en hel del information att ignoreras under projektets gång, men det säkerställer kvalitén på det som faktiskt distribueras vidare i organisationen.
260

Optimization of Material Cost and Carbon Footprint of Flat Reinforced Concrete Slabs with Simple Steel Piles : Designed according to Eurocode and Swedish appendix EKS / Kostnad och växthusgasutsläpps optimering av betonggrund med stålpålar : Med hänsyn till Eurokod och EKS

Lönn, Oskar January 2023 (has links)
When designing reinforced concrete (RC) slabs with steel piles various variables must be considered, from the internal force to the distance of piles. An endless number of designs are possible, leaving space for optimizing designs. The purpose of this thesis is to analyze how different variables may affect the design and how to design for different situations. With the rising interest of the environmental impact of constructions the thesis will analyze both optimal cost and carbon footprint. The analysis is limited to the materials cost and carbon footprint excluding transportation and construction work. To analyze optimized design a method was created to calculate RC slabs using minimum amount of material. Limitations were made analyzing a range of pile distances, acting live loads, pile length, and slab thicknesses. The method used a finite element analysis software to analyze internal forces after creep and crack. A code was programmed to execute the method and extracted results presented as graphs. The results indicated that the smallest slab thickness is the optimal design up to a certain pile distancing. The curve of cost and carbon footprint dependent on the slab thickness flattens out with an increased pile distance. When pile distance is the variable of cost and carbon footprint, an exponential curve is found. The pile length impact on the result is found more prominent for lower live loads. When the slab is exposed to the highest live load (20 MPa) the optimal design is found at the lowest pile distance (2 meters). In general cost and carbon footprint is affected equally. However, there are differences in the results as materials have different ratios between cost and carbon footprint. When designing according to pile distance a shorter distance is more optimal for cost than the carbon footprint.

Page generated in 0.0872 seconds