• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 13
  • 6
  • 4
  • 2
  • 1
  • Tagged with
  • 45
  • 9
  • 8
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Assessment of strength, stiffness, and deformation capacity of concrete squat walls reinforced with GFRP bars / Évaluation de la résistance, la rigidité et la capacité en déformation des voiles courts en béton armé d’armature en PRFV

Arafa, Ahmed January 2017 (has links)
Abstract : The present study addressed the feasibility of reinforced-concrete squat walls totally reinforced with GFRP bars to attain reasonable strength and drift requirements as specified in different codes. Nine large-scale squat walls with aspect ratio (height to length ratio) of 1.33—one reinforced with steel bars (as reference specimen) and eight totally reinforced with GFRP bars—were constructed and tested to failure under quasi-static reversed cyclic lateral loading. The key studied parameters were: (1) use of bidiagonal web reinforcement; (2) use of bidiagonal sliding reinforcement; and (3) web reinforcement configuration (horizontal and/or vertical) and ratio. The reported test results clearly revealed that GFRP-reinforced concrete (RC) squat walls have a satisfactory strength and stable cyclic behavior as well as self-centering ability that assisted in avoiding sliding shear that occurred in the companion steel-reinforced wall following steel yielding. The results are promising regarding using GFRP-reinforced squat walls in areas prone to seismic risk where environmental conditions are adverse to steel reinforcement. Bidiagonal web reinforcement was shown to be more effective than conventional web reinforcement in controlling shear-cracks width. Using bidiagonal sliding reinforcement was demonstrated to be not necessary to prevent sliding shear. The horizontal web reinforcement ratio was found to have a significant effect in enhancing the ultimate strength and deformation capacity as long as the failure is dominant by diagonal tension. Existence of both horizontal and vertical web reinforcement was shown to be essential for cracks recovery. Assessment of the ultimate strengths using the available FRP-reinforced elements code and guidelines (CSA S806-12 and ACI 440.1R-15) was conducted and some recommendations were proposed to attain a reasonable estimation of ultimate strengths. Given their importance in estimating the walls’ later displacement, the effective flexural and shear stiffness of the investigated walls were evaluated. It was found that the cracked shear stiffness could be estimated based on the truss model; while the flexural stiffness can be estimated based on the available expressions in FRP-reinforced elements codes and guidelines. Based on a regression analysis, a simple model that directly correlates the flexural and shear stiffness degradation of the test walls to their top lateral drift was also proposed. / Résumé : La présente étude traite de la faisabilité de voiles courts en béton armé totalement renforcés avec des barres de polymères renforcés de fibres de verre (PRFV), obtenant une résistance et un déplacement latéral raisonnable par rapport aux exigences spécifiées dans divers codes. Neuf voiles à grande échelle ont été construits: un renforcé avec des barres d'acier (comme spécimen de référence) et huit renforcés totalement avec des barres de PRFV. Les voiles ont été testés jusqu’à la rupture sous une charge quasi-statique latérale cyclique inversée. Les voiles ont une hauteur de 2000 mm, une largeur de 1500 mm (élancement 2000 mm/1500 mm = 1,33) et une épaisseur de 200 mm. Les paramètres testés sont : 1) armature bi-diagonale dans l’âme; 2) armature bi-diagonale dans l’encastrement du mur à la fondation (zone de glissement); 3) configuration d’armature verticale et horizontale réparties dans l’âme et taux d’armature. Les résultats des essais ont clairement montré que les voiles courts en béton armé de PRFV ont une résistance satisfaisante et un comportement cyclique stable ainsi qu'une capacité d'auto-centrage qui ont aidé à éviter la rupture par glissement à l’encastrement (sliding shear). Ce mode de rupture (sliding shear) s’est produit pour le voile de référence armé d’acier après la plastification de l’armature. Les résultats sont prometteurs concernant l'utilisation de voiles en béton armé de PRFV dans les régions sismiques dans lesquelles les conditions environnementales sont défavorables à l’armature d’acier (corrosion). L’armature bi-diagonale en PRFV dans l’âme s’est avérée plus efficace pour le contrôle des largeurs de fissures de cisaillement comparativement à l’armature répartie dans l’âme. L'utilisation d'un renforcement de cisaillement bi-diagonal a été démontrée comme n'étant pas nécessaire dans les voiles courts en béton armé de PRFV pour prévenir la rupture par glissement à l’encastrement (shear sliding). Par ailleurs, les résultats d’essais ont montré que le taux d’armature horizontale répartie dans l’âme a un effet significatif sur l’augmentation de la résistance et la capacité en déformation des voiles dont la rupture par effort tranchant se fait par des fissures diagonales (tension failure). L'existence d’armature verticale et horizontale répartie dans l’âme du voile en béton armé de PRFV s'est révélée essentielle pour l’ouverture et la fermeture des fissures au cours des chargements cycliques. Les normes calcul CSA S806-12 et ACI 440.1R-15 ont été utilisées pour évaluer la résistance au cisaillement des voiles courts en béton armé de PRFV. Certaines recommandations ont été proposées pour obtenir une estimation raisonnable des forces ultimes. Compte tenu de leur importance dans l'estimation du déplacement latérale des voiles, la rigidité effective en flexion et en cisaillement des voiles étudiés a été évaluée. On a constaté que la raideur de cisaillement du béton fissuré pourrait être estimée en utilisant le modèle de treillis. La rigidité à la flexion peut être, quant à elle, estimée en fonction des expressions disponibles dans les normes et les guides de conception de membrures en béton armé avec des barres en PRFV. Sur la base d'une analyse de régression, un modèle simple qui corrèle directement la dégradation de la rigidité en flexion et en cisaillement des voiles courts en béton armé de PRFV testés avec le déplacement latérale dans la partie supérieure des voiles a également été proposé.
42

Tlakové ztráty armatur otopných soustav / Pressure loss valves in heating systems

Náglová, Michaela January 2017 (has links)
The theoretical part of the thesis deals with the hydraulics of heating systems. The aim of the project is a design of the heating and hot water preparation system for an apartment building. The building has 6 above-ground floors and 2 underground floors. Two different options of heating systems were designed, comparison and results are presented in the thesis. In the first case the heat source during the winter season and for water heating, where chosen two gas condensing boilers, situated in separated room on the second underground floor. In the second case, each apartment has its own gas condensing boiler. The experimental part of the project deals with measurements of pressure losses in water armatures used in heating systems. The aim of this part is the determination of coefficients of added resistance for uncontrolled elements, which are normally presented as tabular value. In thesis are presented results for a ball valve, backflow preventer, filter, for slide valve and thermostatic valve. Measurements for thermostatic valve where done with different settings and results are compared with parameters listed in the datasheet.
43

Contamination Level Detection of Hydraulic Pressure Filters in Forklifts : using only pump motor currents and load pressure measurements

Sehlstedt, Robert, Sellén, Erik January 2022 (has links)
With the advent of Industry 4.0 and the Internet of Things, collecting data on Cyber-Physical systems has become the norm practice in large scale industries. By collectingrelevant data, it is possible to monitor the health status of whole systems or specificcomponents within them. Such practices allow for historical maintenance strategies suchas reactive maintenance or preventive maintenance to be phased out.In this thesis two separate algorithms are presented, both designed to identify contaminationlevels in the hydraulic pressure filters of forklifts. Furthermore, in contrast torelevant literature for similar applications only sensory data from the hydraulic pump’smotor current and hydraulic fluid pressure at the load was used. More specifically, theproposed algorithms are based on trends observed in the relationship between the measurementsand how it changes over time. The algorithms were evaluated on data fromfour forklifts used in Toyota’s factory. The forklifts had been collecting data while usedin production for over a year.The results indicate strong evidence that both algorithms can be used to detect degradationin the hydraulic system. This is especially true for one forklift where it was knownthat the damage at the time of replacement was substantial. However, it cannot be trulyestablished without further testing whether the algorithms detect degradation in the filteror pump.
44

Les agglomérations "secondaires" gallo-romaines dans le Massif Central : (cités des arvernes, vellaves, gabales, rutenes, cadurques et lémovices), 1er siècle avant J.-C. - Ve siècle après J.-C. / Gallo-Roman "secondary" agglomerations in the Massif Central

Baret, Florian 08 June 2015 (has links)
Parmi les formes d’organisation de l’habitat antique, il en est une qui est longtemps restée en retrait dans la recherche archéologique française. Les agglomérations antiques, qui correspondent à des formes très variées d’habitat groupé, suscitent un intérêt majeur depuis une vingtaine d’années.L’étude historiographique, à l’échelle de la Gaule, fait ressortir un espace en marge des recherches, celui des cités du Massif central. Cette thèse propose donc d’étudier les agglomérations antiques des cités arverne, vellave, gabale, rutène, cadurque et lémovice entre le Ier s. av. J.-C. et le Ve s. ap. J.-C. Les objectifs sont multiples. Il a été nécessaire dans un premier temps d’établir un corpus de sites à partir de la bibliographie régionale. Celui-ci est composé de notices normalisées au sein desquelles l’ensemble des données actuellement disponibles a été présenté. Pour répondre aux questions d’organisation spatiale et de classification, les données bibliographiques recueillies, complétées par des opérations de terrain (prospections terrestres, aériennes, géophysiques, relevés topographiques), ont été synthétisées à partir d’une série de descripteurs archéologiques développés sur le modèle d’Archaeomedes. L’emploi de ces descripteurs a permis la mise en œuvre d’analyses statistiques multivariées afin de dépasser le simple classement par niveaux de fiabilité (sites rejetés, agglomérations hypothétiques, agglomérations avérées). C’est sur la base de la classification retenue après différents tests et sur la hiérarchie urbaine proposée que les analyses spatiales et morphologiques permettent de brosser un tableau complet de l’armature urbaine des cités antiques du Massif central.Les résultats obtenus ont permis d’exposer et de comprendre à la fois les relations entre les agglomérations et le milieu naturel mais aussi avec leur environnement archéologique par l’étude de leurs relations avec l’habitat rural, les chefs-lieux, les limites des cités, leur territoire théorique, les axes de communications terrestres et fluviaux. En changeant d’échelle, l’analyse interne des agglomérations permet d’appréhender à la fois leur morphologie générale mais aussi la place des édifices monumentaux au sein des agglomérations et au sein des cités, le rôle de l’artisanat, les aménagements hydrauliques, … Pour l’analyse de l’armature urbaine, la thèse prend nécessairement en compte l’évolution chronologique des agglomérations à travers leur origine protohistorique, leur évolution durant l’Antiquité et leur devenir au début du Moyen Âge.Pour mener à bien ce travail, il a été nécessaire de croiser les approches documentaires (bibliographie, opérations de terrains), de croiser les échelles d’analyse (du site au Massif central) et de comparer les résultats à ceux des régions voisines. Passées, les analyses statistiques, c’est à partir d’un SIG et d’une base de données que l’ensemble des synthèses a pu être mené.Cette thèse constitue la première synthèse sur les agglomérations antiques des cités du Massif central. Les résultats mettent en avant l’importance des agglomérations dans le système de peuplement et des armatures urbaines variables entre les cités mais qui semblent structurées en partie par le relief et les axes de communications. Les fonctions présentes au sein des agglomérations, si elles sont variées et récurrentes, montrent des spécificités entre les cités mais aussi une hétérogénéité au sein de chacune d’elles. Enfin, l’analyse chronologique montre une réduction du nombre des agglomérations à partir du IIIe siècle mais pas leur disparition. De même, de nouvelles formes d’habitats groupés apparaissent à partir du IVe siècle attestant non pas une crise mais une évolution dans l’organisation urbaine des cités pour répondre à de nouveaux besoins. / Among the forms of organization one can observe in the ancient habitat, there is one particular structure that has been slightly ignored by French archeologists: the lesser urbanized settlements. However, in the last twenty years, small towns have attracted renewed interest.A historiographical study of the Gaul territory highlighted a less studied group of population: the ancient peoples of the Massif Central. In this thesis we intend to have a closer look at such populations as the Arvernes, the Vellaves, the Gabales, the Rutenes, the Cadurques, and the Lemovices from 1st century B.C. - 5th century A.D. We first established a corpus of sites starting with the study of the regional bibliography, which enabled us to create records for each area. We completed this first approach with several field operations such as ground, aerial, geophysical and topographical surveys. All those data were synthesized in a series of archaeological descriptors developed using the Archaeomedes model.The use of such descriptors enabled us to develop some statistical analyses and go beyond the simple reliability factor (which allows the distinction between rejected sites, hypothetical and true urbanized clusters). On the basis of our tested and proven classification, keeping in mind the suggested urban hierarchy and with the help of our spatial and morphological analyses, we were able to obtain a more complete picture of the urban framework of the ancient cities of the Massif Central.The data collected allowed us to better apprehend and understand the relation between such urban clusters and their natural environment, but also to place them in an archaeological context by studying the links between rural housing, the ancient administrative structure (chef-lieu), the city and territory limits, and the major communication routes (land and water). Through a multi-scale study of those population clusters, we were able to determine their general structure, to look at the role of local crafts and trade but also the place of major buildings, and waterworks. We took specific care to the chronological evolution in thosesmall towns by looking at them from their protohistoric beginnings through Antiquity and until early medieval times.While we cross-referenced all the different sources (bibliography and field surveys) and the analysis scales within the Massif Central, we also did a cross-comparison with other neighboring areas in order to validate such work. Besides the statistical data, we used the Geographic Information System and our database to reach our conclusions.This thesis aims at uncovering the reality of those ancient population clusters present in the Massif Central. Our results showed clearly the importance of those in the settlement system, their different forms structured according to the local geography and major trade routes. The functions/positions available in small towns were varied and recurrent but also corresponded to specific trades within each structure while remaining homogeneous.Through our chronological analysis we were able to point out a significant reduction in their numbers starting in the third century, though not their disappearing. In the 4th century new types of population clusters appeared, not as a response to an acute crisis, but more as a result of an evolution called on by new needs.
45

Theoretical and experimental studies on early reinforced concrete structures: contribution to the analysis of the bearing capacity of the Hennebique system / Etudes théoriques et expérimentales des constructions en béton armé de première génération: contribution à l'analyse de la capacité portante du système Hennebique

Hellebois, Armande 02 July 2013 (has links)
In the framework of the conservation of early reinforced concrete structures from the last third of the 19th century up to 1914, this research deals with superstructures (excluding foundations, roads, pipes, etc.) in reinforced concrete (in the modern sense of the term – i.e. concrete made with artificial cement and rebars supplying tensile strength; thus, the combination of a metal profile embedded in concrete is excluded). The development of reinforced concrete as a building material started around 1880 and became widespread around the time of the First World War. Some of the structures concerned are listed as heritage properties today. Therefore they deserve specific and careful study to ensure long-term preservation of their historic, architectural, technical and socio-economic value. They bear witness to a period in construction history when reinforced concrete was a new material. The outbreak of the First World War marked the end of the initial period of innovation, exploration and experimentation. By then, reinforced concrete had become widely accepted and adopted as a suitable and effective building material. However, present-day attempts at restoration often prove inadequate, due to incomplete understanding of this period of construction and the characteristics of the first generation of reinforced concrete. If the causes of degradation are incorrectly diagnosed, the repairs are likely to be inappropriate. Moreover, the number of reinforced concrete structures requiring repair work is currently increasing with the natural ageing of the material. This phenomenon will continue to grow in the coming years.<p><p>With this in mind, the present research aims at identifying the specific structural characteristics of reinforced concrete structures erected before the First World War. Several axes of investigation were pursued in this PhD research and have resulted in the main observations detailed below. <p>- Based on a case study of the region of Brussels (Belgium), a database of structures built in reinforced concrete prior to 1914 was drawn up in order to place the material in its historical and geographical context. The inventory currently contains 507 examples and provides a panorama of the uses of reinforced concrete, ranging from numerous foundations and slabs to a complete structure from the end of the 1890s. This list is supplemented by a survey of a total of 605 patents filed for reinforced concrete in Belgium before the First World War. The early development of reinforced concrete was strongly related to national patenting, with a considerable number of systems being patented by private inventors for commercial purposes. Reinforced concrete profoundly transformed the building industry. All the professions working with the composite material had to change their approach, from the planning stage through to execution on the site. From the viewpoint of construction history, all these modifications make the time of the advent of reinforced concrete a particularly fruitful period to study. <p>- From the survey of early reinforced concrete structures in Brussels and the database of Belgian patents, the supremacy of the Frenchman François Hennebique and his system on the Brussels market for reinforced concrete (and, by extension, on the Belgian market) before 1914 is incontestable. This commercial achievement resulted from a combination of factors: an efficient structural system, meticulous attention to the quality of on-site reinforced concrete execution, and the commercial acumen to develop the business through advertising and other media. The well-known Hennebique system represents a monolithic structure including slabs, beams and columns. In fact, this system changed over the decades of operation of Hennebique’s company, not so much in relation to the design methods (his original semi-empirical method continued to be used) but particularly in practical terms (the type and location of the rebars among others). The evolution of the system is analysed by means of technical drawings from about 30 Belgian projects designed by Hennebique between 1900 and 1930. <p>- After the building contractors, who had been the first to believe in the structural and economic potential of reinforced concrete, engineers invented the calculation models and architects started developing new shapes. The Belgian engineer Paul Christophe was among the first theorists of reinforced concrete. The publication of his book Le béton armé et ses applications in 1899 is internationally recognised as a milestone in the rational modelling of structural reinforced concrete elements. Prior to the present study, details of his life and work remained largely uninvestigated, but the discovery of large parts of his personal archives has allowed clarification of his role in the popularisation of reinforced concrete, especially at the theoretical level.<p>- Reinforced concrete structures around the beginning of the 20th century were initially governed by empirical models of calculation (and execution) developed by the individual constructors. Gradually, reinforced concrete standards, published between 1904 and 1923 and based on working stress analysis and elastic modular ratio theory, replaced the utility of the patented systems. The different theoretical approaches are briefly described in this research. Mastering the theoretical assumptions and calculation methods used at the time represents the first step towards an appreciation of the structural behaviour and the possible weaknesses that can be expected.<p>- A review, based on literature published at that time, of the properties of the components of reinforced concrete allows identification of the characteristic materials used in the concrete matrix and the metal reinforcements. The execution process and the available technological tools for erecting a reinforced concrete structure are also addressed, as these would have had a direct influence on the quality of construction. Non-destructive and destructive experimental laboratory tests were performed on original samples, mainly removed from the Colo-Hugues viaduct (1904, Braine-l’Alleud, Hennebique system) in order to assess the mechanical properties, chemical features and durability issues for concrete and ferrous reinforcements. Comparing the results obtained using different techniques also makes it possible to determine the extent to which these techniques are reliable for the appraisal of early reinforced concrete structures. <p>- The structural efficiency of the Hennebique system is assessed based on an understanding of the principles of Hennebique’s semi-empirical method of calculation, but also – and primarily – by means of observations from experimental tests carried out on full-sized beams removed from the Colo-Hugues viaduct. Analysing and understanding the behaviour of the new composite material was a critical issue for promoting the use of reinforced concrete at the beginning of the 20th century. Today, what is required is a re-assessment of its structural behaviour. Three bending tests up to failure in simply supported conditions were performed at the BATir Department of the Université libre de Bruxelles on T-beams from the Colo-Hugues viaduct. This case study is representative of the majority of Hennebique structures, because the typical continuous straight T-beam is the main structural element of any Hennebique structure (bridge, building, etc.). The first test is a four-point bending test on a complete span (6 m) of the viaduct to obtain the response of the central part under positive bending moment. The flexural failure was ductile and occurred through yielding of the reinforcements followed by crushing of the concrete at mid-span. The second and third tests are three-point bending tests on 4 m long specimens centred on the column, representing the behaviour of the beam around the supports. These showed a sudden slipping failure due to loss of the adhesive bond between rebars. The results of these three experiments combined reproduce the actual behaviour of the viaduct in service. The bearing capacity of the Hennebique system in service and at ultimate has been demonstrated, at least for one loading case. These experimental tests provide essential data for a better understanding of the mechanisms of failure and reveal the main weaknesses of the Hennebique T-beam. Two strengthening solutions are suggested as supplementary information. <p>- The pathologies observed in early reinforced concrete structures (honeycombs, corrosion of the rebars, and so on) are mainly attributable to the tools and techniques that the builders had at their disposal (handmade compaction, high water-to-cement ratio, etc.) and by the limited contemporary knowledge of the physical and chemical phenomena, especially with regard to long-term effects. In fact, the concrete quality of the viaduct is surprisingly satisfactory despite its great age, due to the fact that the whole structure was covered with plaster, like the majority of reinforced concrete structures designed at that time.<p><p>This research establishes that reinforced concrete structures from 1880 to 1914 differ from later reinforced concrete structures. Taking into consideration the features of early reinforced concrete structures will contribute to ensuring sustainable conservation with limited intervention, thus preserving as much as possible of the original structure when restoration work is undertaken. Working on existing buildings often requires a multidisciplinary and holistic approach. The present study could thus be extended in various areas. For example, other structural aspects could be studied more in depth, such as demonstration of the shear strength of the Hennebique system or detailed consideration of the reinforcements (low adherence, particular anchorage devices, etc.)/<p>C'est dans le cadre de la conservation, au sens large du terme, que s'inscrit cette recherche sur les constructions en béton armé de première génération, c'est-à-dire de la fin du 19ème siècle au début du 20ème siècle. Cette recherche traite uniquement des superstructures, à l'exclusion des fondations, routes, tuyaux, etc. et en béton armé au sens moderne du terme, c'est-à-dire un béton réalisé à base de ciment artificiel et dont les armatures interviennent surtout pour reprendre les efforts de traction, ce qui exclut par exemple les utilisations de poutrelles métalliques enrobées de béton. Certains de ces ouvrages, réalisés entre 1880 et 1914, font aujourd'hui partie intégrante du patrimoine bâti, pour leurs valeurs architecturale, historique, technique ou aussi socio-économique. Ils jalonnent désormais l'histoire de la construction comme témoins d'une époque où le béton armé était un matériau nouveau. La Première Guerre mondiale marque la fin de cette période de premières innovations, d'explorations et d'expérimentations. Elle entérine l'acceptation et la diffusion du béton armé comme matériau de construction à part entière. Cependant, ainsi que le montrent certains projets de restauration actuels aux interventions inadéquates, il y a encore une méconnaissance des spécificités du béton armé de cette époque. Les causes de leurs dégradations mal diagnostiquées sont traitées de façon inappropriée. Or, dans les prochaines années, nombre de structures en béton armé construites dans la première moitié du 20ème siècle seront amenées à subir une rénovation suite au vieillissement naturel du matériau. C'est pourquoi pour conserver au mieux ces structures, il est indispensable d'étudier en détails leurs caractéristiques techniques pour ensuite intervenir, si nécessaire, de façon précise et adaptée.<p><p>Ce doctorat s'attèle donc à identifier les particularités des constructions en béton armé construites avant l'avènement de la Première Guerre mondiale, et plus spécifiquement à étudier leurs aspects structuraux. Plusieurs axes de recherche ont été développés et ont abouti aux principaux résultats suivants. <p>- Basé sur le cas de la région de Bruxelles-Capitale (Belgique), un inventaire des interventions en béton armé, construites avant 1914, a été dressé pour replacer le matériau dans son contexte historique et géographique. Cette base de données, comprenant 507 biens jusqu'à présent, illustre les types d'utilisation du béton armé dans la construction au début du 20ème siècle, d'abord des fondations ou simples planchers, jusqu'à une structure monolithique complète dès la fin des années 1890. Cet inventaire est complété par le relevé détaillé des brevets, au nombre de 605, déposés à ce sujet en Belgique avant la Première Guerre mondiale. Les brevets ont joué un rôle fondamental dans le développement du béton armé. Celui-ci était, en effet, régi par un foisonnement de systèmes commerciaux, majoritairement brevetés. L'introduction du béton armé a transformé en profondeur le secteur de la construction et notamment les professions liées tant à la phase de conception qu'au chantier lui-même. Du point de vue de l'histoire de la construction, toutes ces mutations font de l'avènement du béton armé une période historique riche. <p>- A la lecture du panorama offert par les inventaires des constructions et des brevets, la prééminence de la compagnie du Français François Hennebique, et donc de son système, sur le marché bruxellois (et par extrapolation sur le marché belge) du béton armé avant 1914 est indéniable. La réussite commerciale de Hennebique résulte d'une combinaison de facteurs: un système efficace sur le plan structural, une qualité d'exécution de béton coulé en place fiable et méticuleuse ainsi qu'un sens développé des affaires, en maîtrisant l'art de la promotion et de la publicité notamment. Le système bien connu de Hennebique comprend un ensemble monolithique formé par des dalles (hourdis), poutres et colonnes. Ce système a, en réalité, évolué dans le temps, pas tant d'un point de vue théorique (les calculs de dimensionnement sont les mêmes) mais plutôt pratique (positionnement, type d'armatures, etc.). Cette évolution a été observée par l'étude d'une trentaine de cas pratiques exécutés par Hennebique entre 1900 et 1930 en Belgique.<p>- Après les entrepreneurs, qui ont été les premiers à croire aux nouvelles possibilités constructives qu'offre le béton armé ainsi qu'à son succès commercial, les ingénieurs en inventent les principes de calcul et les architectes en révolutionnent les formes. L'ingénieur belge Paul Christophe fut parmi les premiers théoriciens du béton armé. La publication de son ouvrage Le béton armé et ses applications en 1899 constitue une étape importante, et internationalement reconnue, pour le dimensionnement rationnel d'éléments structuraux en béton armé. Jusqu'à la présente recherche, sa vie et son œuvre étaient restées assez confidentielles mais la découverte d'une partie de ses archives personnelles a permis de clarifier son rôle dans la diffusion, surtout théorique, du béton armé. <p>- Les structures en béton armé d'avant la Première Guerre mondiale furent d'abord gouvernées par des méthodes empiriques de dimensionnement (et d'exécution) développées par chaque constructeur. L'apparition des premières règlementations entre 1904 et 1923, basées sur une analyse en contraintes admissibles et la théorie du coefficient d'équivalence, remplace ensuite peu-à-peu l'utilité des systèmes brevetés. Les différentes approches théoriques sont brièvement décrites dans cette recherche. Maitriser les hypothèses et les méthodes de calculs employées à l'époque est, en effet, une première étape pour comprendre le fonctionnement structural prévu et les potentielles défaillances de dimensionnement. <p>- A travers une lecture attentive de la littérature publiée à cette période, les matériaux intervenants dans la fabrication du béton armé (c'est-à-dire le béton et les armatures) et utilisés couramment au début du 20ème siècle ont été identifiés ainsi que les moyens disponibles à cette époque pour produire des structures en béton armé. Des méthodes d'essais non-destructives et destructives ont été appliquées principalement, sur le viaduc Colo-Hugues (1904, Braine-l'Alleud, système Hennebique) afin d'évaluer les caractéristiques mécaniques, les propriétés chimiques et la durabilité tant du béton que des renforcements métalliques. Comparer les résultats de ces différentes méthodes permet d'aborder les limites d'utilisation de ces techniques, lorsqu'il s'agit d'évaluer structuralement des bétons armés de première génération. <p>- Grâce à la compréhension des principes, semi-empiriques, de dimensionnement appliqués par le bureau Hennebique en son temps mais surtout grâce aux observations déduites des essais expérimentaux réalisés sur des poutres de grandeur réelle, prélevées sur le viaduc Colo-Hugues, le fonctionnement structural réel du système Hennebique est évalué. Comprendre et modéliser le comportement du nouveau matériau composite fut une problématique fondamentale pour accroître l'usage du béton armé au début du 20ème siècle. Actuellement, il s'agit de réévaluer le comportement de ces structures. Trois essais jusqu'à rupture ont été menés, au département BATir de l'Université libre de Bruxelles, sur des poutres à gousset en T provenant du viaduc Colo-Hugues en conditions isostatiques et soumises à flexion. Ce viaduc des chemins de fer vicinaux est un cas d'étude représentatif de la majorité des constructions Hennebique, car la poutre de section en T est la structure typique du système Hennebique, utilisée tant dans les ouvrages d'art que dans les bâtiments. Le premier essai est une flexion 4 points sur une travée complète du viaduc (6 m de portée) pour obtenir la réponse en zone de moment maximum positif. La rupture ductile a eu lieu par plastification des armatures suivie d'un écrasement du béton en zone centrale, c'est-à-dire dans la zone la plus sollicitée. Deux éléments identiques de longueur de 4 m ont été essayés en flexion 3 points pour représenter le comportement sur appuis. La rupture de ces deux dernières expériences s'est produite suite à un glissement des armatures sur appuis (goussets à côté de la colonne). Il s'agit donc d'une rupture à caractère fragile. Les trois essais combinés représentent correctement la structure hyperstatique du viaduc dans son fonctionnement en service. La capacité portante réelle du système Hennebique en service et à l'état limite ultime, du moins dans un cas de chargement, a pu être expliquée. Ces essais fournissent les données essentielles pour estimer l'efficacité structurale du système Hennebique et identifier ses faiblesses. Deux solutions de renforcement sont proposées en complément d'information.<p>- Les pathologies observées dans les bétons armés datant du début du 20ème siècle (nids de graviers, corrosion des armatures, etc.) sont, la plupart du temps, causées par les outils sommaires à la disposition des constructeurs (vibration à la main, rapport eau/ciment plus élevé qu'aujourd'hui, etc.) et par une connaissance limitée des phénomènes physiques et chimiques, surtout à long terme. En fait, la qualité du béton du viaduc Colo-Hugues est particulièrement satisfaisante malgré l'âge avancé du béton, grâce notamment à l'enduit recouvrant l'ensemble du viaduc, ce qui est le cas pour la majorité des structures de la période étudiée.<p><p>Cette recherche démontre que les constructions en béton armé datant de 1880 à 1914 diffèrent des ouvrages postérieurs en béton armé et qu'il serait utile pour leur restauration de tenir compte de ces spécificités. La connaissance approfondie des particularités des constructions en béton armé de première génération permettra, espérons-le, de contribuer à leur longévité en intervenant le moins possible sur les structures d'origine. Etant donné que l'étude des structures existantes nécessite le plus souvent une approche pluridisciplinaire, ce travail pourrait être poursuivi dans plusieurs domaines variés. Il resterait notamment à approfondir d'autres aspects de stabilité, comme par exemple la démonstration de l'efficacité à l'effort tranchant du système Hennebique ou encore la prise en considération plus détaillée des armatures (adhérence limitée, forme d'ancrage particulier, etc.). / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished

Page generated in 0.0629 seconds