• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 73
  • 35
  • 35
  • 32
  • 28
  • 26
  • 26
  • 25
  • 24
  • 24
  • 20
  • 11
  • 10
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Perfil audiológico de adultos com e sem hipertensão arterial / Audiological profile of adults with and without arterial hypertension

Soares, Mariana Aparecida 16 May 2014 (has links)
Introdução: Sabe-se que muitas pessoas sofrem de hipertensão arterial sistêmica (HAS) e indivíduos cada vez mais jovens estão apresentando este quadro. A HAS pode causar várias complicações na saúde geral do indivíduo, em virtude do comprometimento da circulação sanguínea, o que pode afetar até mesmo o sistema auditivo. Porém, os estudos encontrados na literatura, até o momento, são bastante controversos quanto à influência ou não da HAS no sistema auditivo periférico. Objetivos: Verificar se existe influência da hipertensão arterial no sistema auditivo periférico, por meio dos achados na audiometria de altas frequências, nas emissões otoacústicas transientes e produto de distorção, comparando grupos de indivíduos normoouvintes pela audiometria convencional, com e sem HAS; e identificar se alguma das variáveis referentes às avaliações realizadas pode ser utilizada para discriminar os indivíduos nos grupos com ou sem HAS. Método: Participaram deste estudo 40 sujeitos de 30 a 50 anos, divididos em grupos com e sem hipertensão arterial. Todos os indivíduos foram submetidos à meatoscopia, imitanciometria, audiometria tonal nas frequências de 250 Hz a 16000 Hz, logoaudiometria, emissões otoacústicas evocadas transientes e emissões otoacústicas produto de distorção. Resultados: Não foi observada diferença estatisticamente significante entre os grupos com e sem HAS na audiometria convencional e em altas frequências. Para as emissões otoacústicas evocados por estímulo transiente, houve tendência à diferença estatisticamente significante, com as respostas do grupo com HAS piores que do grupo sem HAS. Já as emissões otoacústicas produto de distorção, nas frequências de 1501, 2002 e 3003 Hz, apresentaram diferenças estatisticamente significantes, sendo que o grupo com HAS apresentou amplitudes menores. A análise discriminante mostrou que as variáveis das emissões otoacústicas produto de distorção foram as que melhor discriminaram os indivíduos com e sem HAS. Conclusão: Nossos achados sugerem presença de disfunção coclear em indivíduos com hipertensão arterial, uma vez que as respostas das emissões otoacústicas foram piores no grupo com HAS / Introduction: It is widely known that many people have systemic arterial hypertension (SAH) and, currently, the number of young people with such disease is increasing. SAH may cause a wide range of complications in the general health of an individual due to the involvement of blood circulation, which may affect the hearing system. Nevertheless, the reports found in the scientific field are still controversial regarding the influence of SAH on the peripheral auditory system. Purpose: To verify if there is any influence of SAH on the peripheral auditory system, through data from high frequency audiometry, transient-evoked otoacustic emissions and distortion-product otoacoustic emissions and compare such results to groups of typical hearing individuals, with and without SAH, who underwent the pure-tone audiometry test; and also investigate if any variable regarding the hearing assessment may be used to differentiate individuals with and without SAH. Methods: This study counted on 40 individuals aged between 30 and 50 years old, divided into groups with and without SAH. All individuals underwent the following procedures: otoscopy, imitanciometry, pure-tone audiometry in frequencies from 250Hz to 16000 Hz, logoaudiometry, transient-evoked otoacoustic emissions and distortion-product otoacoustic emissions. Results: There was found no significant statistically difference between the groups with and without SAH neither in pure-tone nor high-frequency audiometry. Regarding transient-evoked otoacustic emissions there was a tendency to a significant statistically difference once the SAH group showed lower results. Concerning distortion-product otoacustic emissions there was found significant statistically difference in the following frequencies: 1501, 2002 e 2003 Hz in which the SAH group showed lower results. Discriminant analysis pointed that variables of distortion-product otoacustic emissions best distinguished individuals with and without SAH. Conclusion: Data from this study suggest cochlear dysfunction in individuals with SAH since their results in otoacoustic emissions were lower than in the group with SAH
42

Telessaúde: sistematização e avaliação da eficácia da teleconsulta na programação e adaptação de aparelho de amplificação sonora individual / Audiology telehealth: systematization and evaluation of teleconsultation efficacy for hearing aid programming and fitting

Campos, Patricia Danieli 18 May 2011 (has links)
Uma sistemática de teleconsulta para o processo de programação, verificação e adaptação dos aparelhos de amplificação sonora individuais (AASI) foi desenvolvida e sua eficácia avaliada por meio de um estudo prospectivo, randomizado e cego. Participaram do estudo 50 deficientes auditivos (30 homens; 20 mulheres) candidatos ao uso do AASI, com idades variando entre 39 e 88 anos e média ISO dos limiares audiométricos entre 30 e 68,75dB. Os participantes foram alocados em dois grupos (randomização estratificada): controle (n=25), submetidos aos procedimentos face a face (F) e experimental (n=25) submetidos à teleconsulta (T). O procedimento F foi realizado pelo avaliador 1 em todos os participantes, incluindo: programação do AASI, medidas com microfone sonda (equipamento Unity PC Probe, estímulo speech noise, apresentado em 50, 65 e 80dBNPS) e orientação quanto ao uso e cuidados com o AASI. Para a teleconsulta o participante e um facilitador se posicionaram na sala junto aos equipamentos (ambiente de teste). O avaliador 1 posicionou-se em outra sala (ambiente remoto) com um notebook conectado à LAN USP. Webcams e headsets capturaram áudio e vídeo, transmitidos em tempo real pelo software Polycom PVX (384 kbps), também utilizado para compartilhamento de aplicativos. Por meio desse compartilhamento o avaliador 1 realizava todos os procedimentos diretamente no participante, com auxílio do facilitador. O tempo despendido para as consultas F e T foi cronometrado. Após as consultas o avaliador 2, cego quanto aos grupos, realizou a avaliação de percepção da fala (Hearing in Noise Test - HINT Brasil) para obter o limiar de reconhecimento de fala no silêncio (LRF) e a relação sinal/ruído (S/R) em que os participantes reconheciam 50% das sentenças apresentadas. Aproximadamente um mês após as consultas foi realizada (avaliador 2) a análise do tempo diário de uso do AASI (via datalogging do dispositivo) e do benefício e satisfação em vida diária (questionário International Outcome Inventory for Hearing Aids - IOI-HA). Maior tempo para a programação e verificação e menor tempo para orientação foi observado para o grupo experimental, sendo este estatisticamente significativo (teste t de Student). Não houve diferença entre grupos no tempo total do atendimento em minutos (82,2 controle e 81,3 experimental). A equiparação das medidas com microfone sonda aos respectivos targets foi similar para os dois grupos. Não houve diferença significativa (teste t) entre as médias do LRF no silêncio (56,24 controle e 51,78 experimental) e da relação S/R (4,94 controle e 4,17 experimental), o tempo médio de uso do AASI em horas (7,26 controle e 7,44 experimental) e das pontuações total e dos itens do questionário IOI-HA. Houve correlação (Spearman) positiva forte e significativa entre o tempo de uso do AASI e o tempo de uso informado pelo participante, para ambos os grupos. Para alguns participantes durante a teleconsulta houve interrupção da transmissão de áudio e vídeo que foi prontamente solucionada. Concluiu-se que a teleconsulta é um procedimento eficaz para a realização da programação, verificação do AASI e orientação de usuários quando, por algum motivo, serviços face a face não estiverem disponíveis. / A teleconsultation system for hearing aid (HA) programming, verification and fitting has been developed and its efficacy assessed through a prospective, randomized and blind study. Fifty hearing impaired individuals (30 men; 20 women), HA candidates, in the age range 39 - 88 years and ISO mean of audiometric thresholds between 30 and 68.75dBNA, participated in the study. The participants were divided into two groups (stratified randomization): control (n=25), submitted to face to face procedures (F) and experimental (n=25), submitted to teleconsultation (T). Procedure F was performed by evaluator 1 in all participants: HA programming, probe microphone measures (Unity PC Probe equipment, speech noise stimulus presented at 50, 65 and 80dBSPL) and HA use and care orientation. For the teleconsultation, the participant and a facilitator positioned themselves in the room with the equipment (test environment). Evaluator 1 stayed in another room (remote environment) with a notebook connected to the LAN USP. Webcams and headsets captured audio and video, transmitted in real time by software Polycom PVX (384 kbps), utilized as well for application sharing, through which evaluator 1 performed all the procedures directly in the patient, aided by the facilitator. The time spent for consultations F and T was recorded. Following the consultations, evaluator 2, blind to the groups, performed the speech perception assessment (Hearing in Noise Test - HINT Brazil) so as to obtain the speech reception threshold (SRT) in silence and the signal/noise ratio (S/N) in which the participants recognized 50% of the sentences presented. Nearly a month following the consultations the evaluator 2 carried out the analysis of daily time of HA use (via datalogging of the device) as well as benefit and satisfaction (questionnaire International Outcome Inventory for Hearing Aids - IOI-HA). An statistically significant (Students t test) greater time for the programming and verification and a smaller one for HA orientation were observed for the experimental group. No difference was found between the groups for the total consultation time in minutes (control: 82.2; experimental: 81.3). The real ear measures matching to targets were similar for the both groups. No significant difference was observed (Students t test) between the means of SRT in silence (56.24 control and 51.78 experimental) as well as the S/N ratio (4.94 control and 4.17 experimental), the daily amount HA use in hours (7.26 control and 7.44 experimental) and the IOI scores. For both groups there was a positive, strong and significant correlation (Spearman) between the daily amount of HA use (datalogging) and the reported HA use. For some participants, during the teleconsultation, the transmission of audio and video was interrupted, but readily restored. Conclusion: teleconsultation is an effective procedure for hearing aid programming, verification and fitting when face to face services are not available.
43

Aspectos epidemiológicos da saúde auditiva com ênfase na impactação do cerume em residentes de uma Instituição de longa permanência da cidade de Bauru, SP / Epidemiological aspects of hearing health with emphasis on cerumen impaction among residents in homes for aged of the city of Bauru, SP

Damasceno, Rafael José 22 April 2013 (has links)
O processo de envelhecimento compreende um fenômeno natural, marcado por mudanças orgânicas graduais, refletidas nas esferas cultural, social e emocional. Em particular, no campo sensorial, há as alterações auditivas, tal como a presbiacusia. Todavia, nesta temática das possíveis causas propulsoras da perda auditiva, um determinante por vezes menosprezado é a denominada impactação do cerume, coloquialmente definida como a rolha de cera. Aliado a estes, nesta faixa populacional, é considerada limitada os cuidados com a saúde auditiva. Assim, o objetivo deste trabalho foi realizar um levantamento epidemiológico sobre a saúde auditiva, enfatizando a presença da impactação do cerume, em idosos residentes em uma instituição de longa permanência da cidade de Bauru, SP. A amostra foi composta por 26 residentes de uma ILPI, os quais passaram por um questionário inicial sobre a saúde auditiva, além de uma inspeção do meato acústico externo, realizado pro uma fonoaudióloga. Nos resultados, pode-se observar uma considerável percepção de perda auditiva (34,6%) e otalgia (30,8%), além de um baixo percentual de residentes que realizam consultas ao fonoaudiólogo, bem como exames audiológicos. Com relação à higienização do meato acústico externo, 85% o efetuam, sendo que em 59% destes, a retirada do cerume é a motivação chave. Já, dentre os itens utilizados para tal procedimento, enquadram-se, as hastes flexíveis, toalha, fósforos, grampos e o dedo. Na inspeção, 54% apresentaram a impactação, sendo que em 19% apresentou-se bilateralmente. Dentro desta temática, ressalta-se que só houve diferença estatisticamente significante entre a impactação do cerume e o uso de grampos. Deste modo, pode-se concluir que houve uma elevada incidência da impactação do cerume nos residentes, os quais realizam a higienização do meato acústico externo de maneira errônea. Destaque também para o baixo índice de consultas fonoaudiológicas e exames audiológicos. / The aging process includes a natural phenomenon marked by gradual organic change, reflected in the cultural, social and emotional aspects. In particular, the sensory field, there are the hearing disorders such as presbyacusis. However, the possible causes of hearing loss propulsion, a sometimes overlooked determinant is called cerumen impaction. In addition to these, in this age group, is considered limited the health care hearing. So, the objective of this study was perform an epidemiological survey on hearing health, emphasizing the presence of cerumen impaction in elderly residents of an ILPI from the city of Bauru, SP. The sample was composed of 26 home residents, who underwent an initial questionnaire about hearing health, and an inspection of the external ear canal. In the results, could observe a considerable awareness of hearing loss (34,6%) and pain (30,8%), and a low percentage of residents who hold consultations to speech language pathologist and audiological tests. Regarding the cleaning of the external auditory canal, 85% made it and in 59% of these, the removal of cerumen is the key motivation. Already, among the items used for this procedure there were fit, flexible rods, towel, matches, staples and fingers. In the inspection, 54% had impaction, and in 19% it was bilateral. Besides these, there was only a statistically significant difference between the cerumen impaction and the use for staples. Therefore, were concludes that there was a high incidence of cerumen impaction of the residents, which perform the cleaning of the ear canal erroneously. Highlight for the low level of visits speech language pathologist to and audiological tests.
44

Aspectos epidemiológicos da saúde auditiva com ênfase na impactação do cerume em residentes de uma Instituição de longa permanência da cidade de Bauru, SP / Epidemiological aspects of hearing health with emphasis on cerumen impaction among residents in homes for aged of the city of Bauru, SP

Rafael José Damasceno 22 April 2013 (has links)
O processo de envelhecimento compreende um fenômeno natural, marcado por mudanças orgânicas graduais, refletidas nas esferas cultural, social e emocional. Em particular, no campo sensorial, há as alterações auditivas, tal como a presbiacusia. Todavia, nesta temática das possíveis causas propulsoras da perda auditiva, um determinante por vezes menosprezado é a denominada impactação do cerume, coloquialmente definida como a rolha de cera. Aliado a estes, nesta faixa populacional, é considerada limitada os cuidados com a saúde auditiva. Assim, o objetivo deste trabalho foi realizar um levantamento epidemiológico sobre a saúde auditiva, enfatizando a presença da impactação do cerume, em idosos residentes em uma instituição de longa permanência da cidade de Bauru, SP. A amostra foi composta por 26 residentes de uma ILPI, os quais passaram por um questionário inicial sobre a saúde auditiva, além de uma inspeção do meato acústico externo, realizado pro uma fonoaudióloga. Nos resultados, pode-se observar uma considerável percepção de perda auditiva (34,6%) e otalgia (30,8%), além de um baixo percentual de residentes que realizam consultas ao fonoaudiólogo, bem como exames audiológicos. Com relação à higienização do meato acústico externo, 85% o efetuam, sendo que em 59% destes, a retirada do cerume é a motivação chave. Já, dentre os itens utilizados para tal procedimento, enquadram-se, as hastes flexíveis, toalha, fósforos, grampos e o dedo. Na inspeção, 54% apresentaram a impactação, sendo que em 19% apresentou-se bilateralmente. Dentro desta temática, ressalta-se que só houve diferença estatisticamente significante entre a impactação do cerume e o uso de grampos. Deste modo, pode-se concluir que houve uma elevada incidência da impactação do cerume nos residentes, os quais realizam a higienização do meato acústico externo de maneira errônea. Destaque também para o baixo índice de consultas fonoaudiológicas e exames audiológicos. / The aging process includes a natural phenomenon marked by gradual organic change, reflected in the cultural, social and emotional aspects. In particular, the sensory field, there are the hearing disorders such as presbyacusis. However, the possible causes of hearing loss propulsion, a sometimes overlooked determinant is called cerumen impaction. In addition to these, in this age group, is considered limited the health care hearing. So, the objective of this study was perform an epidemiological survey on hearing health, emphasizing the presence of cerumen impaction in elderly residents of an ILPI from the city of Bauru, SP. The sample was composed of 26 home residents, who underwent an initial questionnaire about hearing health, and an inspection of the external ear canal. In the results, could observe a considerable awareness of hearing loss (34,6%) and pain (30,8%), and a low percentage of residents who hold consultations to speech language pathologist and audiological tests. Regarding the cleaning of the external auditory canal, 85% made it and in 59% of these, the removal of cerumen is the key motivation. Already, among the items used for this procedure there were fit, flexible rods, towel, matches, staples and fingers. In the inspection, 54% had impaction, and in 19% it was bilateral. Besides these, there was only a statistically significant difference between the cerumen impaction and the use for staples. Therefore, were concludes that there was a high incidence of cerumen impaction of the residents, which perform the cleaning of the ear canal erroneously. Highlight for the low level of visits speech language pathologist to and audiological tests.
45

Processo de introdução de triagem auditiva neonatal em um hospital filantrópico de Belo Horizonte

Abreu, Ana Célia Pereira de 28 August 2007 (has links)
Made available in DSpace on 2016-04-27T18:12:23Z (GMT). No. of bitstreams: 1 Ana Celia Pereira de Abreu.pdf: 220373 bytes, checksum: ff97f4050143452b4ea098dc1bf2b92f (MD5) Previous issue date: 2007-08-28 / The early diagnosis of auditory deficiencies is one of the decisive factors for the better development of the language functions of a deficient child. It is during childhood that the neurological maturation occurs, thus favoring the development of the basic perceptive abilities, as well as of language itself. Given the importance the early auditory deficiency diagnosis, programmes of universal neonatal hearing screening have been proposed world-wide. With the aim of implementing a neonatal hearing screening programme that has an efficient protocol, this study describes the findings of a hearing screening programme conducted with 140 babies born at the Hospital Evangélico de Belo Horizonte in the period between April and June 2005, utilizing two forms of scheduling: hearing screening conducted 15 days after hospital release and hearing screening conducted immediately after hospital release. The methodology utilized in the study includes: anamnesis of the prenatal, neonatal and postnatal conducted through interviews with the mothers, hearing screening using Transient Evoked Otoacoustic Emissions, Distortion Product Otoacoustic Emissions and research of the Eye-Blink Reflex (EBR). Of the 228 (100%) babies born in this period at the hospital, of which 138 (65,7%) were born in April and 72 (34,3%) in June, 210 (92,1%) have been recruited to have the hearing screening test administered. In the April group hearing screening was scheduled for 15 days after hospital release and in the June group hearing screening was scheduled immediately after hospital release. Of the 210 (100%) babies recruited, 140 (66,6%) attended triage, of which 70 (50,7%) belonged to the 15-day group and 70 (97,2%) to the Release group. Of the 70 (100%) evaluated babies in the 15-day group, 6 (8,5%) have presented indicators of risk of auditory deficiency; and of the 70 (100%) evaluated babies in the Release group, 6 (8,5%) have also presented indicators of risk auditory deficiency. Of all the babies evaluated, 140 (100%) presented EBR. In the research of both the transient evoked and distortion product otoacoustic emissions, 2 babies (2,9%) of the 15-day group have failed the evaluation, and in the Release group 22 (31,4%) have also failed. The findings of this study have demonstrated that the failure rate of the 15-day group in the otoacoustic emission test is lower when compared to the rate of the Release Group, however the consent to the test went higher in this group, given that the ease of having the test performed at the moment of release does not require the mother to return to the hospital / O diagnóstico precoce da deficiência auditiva é um dos fatores decisivos para o melhor desenvolvimento da linguagem da criança com deficiência. É na infância que ocorre a maturação neurológica, favorecendo o desenvolvimento das habilidades perceptivas básicas, bem como a linguagem. Tendo em vista a importância do diagnóstico precoce da deficiência auditiva, programas de triagem auditiva neonatal universal têm sido propostos mundialmente. Com o objetivo de implantar um programa de triagem auditiva neonatal com um protocolo eficiente, este estudo descreve os achados de um programa de triagem auditiva, realizado em 140 bebês nascidos no Hospital Evangélico de Belo Horizonte no período de Abril e Junho de 2005, em duas formas de agendamento: triagem auditiva realizada 15 dias após a alta hospitalar e triagem auditiva realizada imediatamente após a alta hospitalar. A metodologia utilizada no estudo incluiu: anamnese dos períodos pré-natal, neonatal e pós- natal, realizada por meio de entrevistas com as mães; triagem auditiva realizada com Emissões Otoacústicas Transientes, Emissões Otoacústicas Produto de Distorção e pesquisa do Reflexo Cócleo Palpebral (RCP). Dos 228 (100%) bebês que nasceram neste período no hospital, foram recrutados para realizar a triagem auditiva 210 (92,1%), sendo 138 (65,7%) nascidos em abril e 72 (34,3%) nascidos em junho. No grupo abril a triagem auditiva foi marcada para 15 dias após a alta hospitalar e no grupo junho a triagem auditiva foi marcada imediatamente após a alta hospitalar. Dos 210 (100%) bebês recrutados compareceram para triagem 140 (66,6%), sendo 70 bebês (50,7%) do grupo 15 dias e 70 bebês (97,2%) do grupo alta. Dos 70 (100%) bebês avaliados no grupo 15 dias, 6 (8,5%) apresentaram indicadores de risco para deficiência auditiva; e dos 70 (100%) bebês avaliados no grupo alta, 6 (8,5%) apresentaram também indicadores de risco para deficiência auditiva. De todos os bebês avaliados, 140 (100%) apresentaram RCP. Na pesquisa das emissões otoacústicas, tanto transiente quanto produto de distorção, no grupo 15 dias 2 bebês (2,9%) falharam e no grupo alta 22 (31,4%) também falharam. Os achados deste estudo demonstraram que no grupo 15 dias o índice de falha no exame de emissões otoacústicas é menor quando comparado ao grupo alta; porém, a adesão ao exame foi maior neste grupo, pois a facilidade em realizar o exame no momento da alta não exige que a mãe retorne ao hospital
46

Estudo da via auditiva em cães beagles por meio de potenciais auditivos de tronco encefálico

Stefanello, Carine Ribas January 2017 (has links)
O teste de potencial auditivo de tronco encefálico (PEATE) permite captar e registrar as atividades elétricas do sistema auditivo, desde a cóclea até o tronco encefálico. No Braisl ainda é pouco utilizado, e no Sul do país ainda não é realizado em animas.O objetivo deste trabalho foi identificar os valores absolutos de latência, interpicos, amplitudes, comparar as polaridades de compressão e rarefação e conhecer o limiar auditivo em onze cães hígidos da raça Beagle. Os cães passaram por exame físico e neurológico e após foram sedados e submetidos a otoscopia e ao exame de Potencial Auditivo de Tronco Encefálico (PEATE). Foram utilizados eletrodos de superfície e fones de inserção, o estimulo utilizado foi o clique com estimulação bilateral. O teste foi iniciado com a intensidade de 90 dB SPL com polaridade condensada. Realizava-se na sequência mais uma pesquisa em 90 dB SPL com polaridade rarefeita. Após, foi feito o exame com diminuição da intensidade de 10 dB SPL em 10 dB SPL, sendo todas as pesquisas feitas com polaridade condensada, para a pesquisa dos limiares auditivos. A interpretação do PEATE, foi realizada pela avaliação das ondas I, III e IV, pela identificação das latências absolutas e interpicos, pesquisa do limiar auditivo e comparação entre polaridades. Na latência da onda I com polaridade rarefeita em 90 dB SPL, os valores médios de latência absoluta da onda I foram significativamente maiores na orelha esquerda (p=0,037*). Dados relativos à latência absoluta da onda V evidenciou que na orelha direita a latência foi significativamente menor na intensidade de 70 dB SPL, e não houve presença de onda V na orelha esquerda em 40 dB SPL. Não houveram diferenças significativas nas latências dos interpicos entre as orelhas direita e esquerda, com polaridade condensada e rarefeita. Os valores das medianas das amplitudes I, III e V com 90 dB SPL em compressão e rarefação, não diferiram estatisticamente. Concluiu-se que o nível de resposta mínimo se encontrou entre 40 dB SPL e 80 dB SPL. / The Brainstem Auditory Evoked Potential (BAEP) capture and record the electrical activity of the auditory system, from the cochlea to the brainstem. The Brazil is still little used, and in the South of the country is not yet done in animals. The objective of this study was to identify the absolute values of latency, interpeaks, amplitudes, compare the polarities of compression and rarefaction and to know the auditory threshold in eleven healthy beagle dogs. The dogs underwent physical and neurological examination and were sedated and submitted to otoscopy and Brainstem Auditory Evoked Potential (BAEP). Surface electrodes and insertion headphones were used, the stimulus used was the click with bilateral stimulation. The test was started with 90 dB SPL intensity with condensed polarity. Further research was conducted on 90 dB SPL with rarefied polarity. After that, the test was performed with sequential reductions of 10 dB SPL intensity, and all the research for the auditory thresholds was done with condensed polarity. The interpretation of BAEP was performed by the evaluation of waves I, III and IV, by the identification of the absolute and interpeak latencies, auditory threshold research and comparison between polarities. In wave I latency with a rarefied polarity of 90 dB SPL, the mean absolute values of wave I latency were significantly higher in the left ear (p = 0.037*). Data on absolute V wave latency showed that, in the right ear, the latency was significantly lower in the intensity of 70 dB SPL, and there was no presence of V wave in the left ear in 40 dB SPL. There were no statistically significant differences in the interpeak latencies between the right and left ears, with condensed and rarefied polarity. The values of the medians of amplitudes I, III and V with 90 dB SPL in compression and rarefaction did not differ statistically. The minimum response level was found between 40 dB SPL and 80 dB SPL.
47

Cultura, linguagem e fonoaudiologia: uma escuta do discurso familiar no contexto da saude publica

Lopes, Stella Maris Brum. January 2001 (has links) (PDF)
Mestre -- Universidade de Sao Paulo. Faculdade de Saude Publica. Departamento de Pratica de Saude Publica, Sao Paulo, 2001.
48

Estudo da via auditiva em cães beagles por meio de potenciais auditivos de tronco encefálico

Stefanello, Carine Ribas January 2017 (has links)
O teste de potencial auditivo de tronco encefálico (PEATE) permite captar e registrar as atividades elétricas do sistema auditivo, desde a cóclea até o tronco encefálico. No Braisl ainda é pouco utilizado, e no Sul do país ainda não é realizado em animas.O objetivo deste trabalho foi identificar os valores absolutos de latência, interpicos, amplitudes, comparar as polaridades de compressão e rarefação e conhecer o limiar auditivo em onze cães hígidos da raça Beagle. Os cães passaram por exame físico e neurológico e após foram sedados e submetidos a otoscopia e ao exame de Potencial Auditivo de Tronco Encefálico (PEATE). Foram utilizados eletrodos de superfície e fones de inserção, o estimulo utilizado foi o clique com estimulação bilateral. O teste foi iniciado com a intensidade de 90 dB SPL com polaridade condensada. Realizava-se na sequência mais uma pesquisa em 90 dB SPL com polaridade rarefeita. Após, foi feito o exame com diminuição da intensidade de 10 dB SPL em 10 dB SPL, sendo todas as pesquisas feitas com polaridade condensada, para a pesquisa dos limiares auditivos. A interpretação do PEATE, foi realizada pela avaliação das ondas I, III e IV, pela identificação das latências absolutas e interpicos, pesquisa do limiar auditivo e comparação entre polaridades. Na latência da onda I com polaridade rarefeita em 90 dB SPL, os valores médios de latência absoluta da onda I foram significativamente maiores na orelha esquerda (p=0,037*). Dados relativos à latência absoluta da onda V evidenciou que na orelha direita a latência foi significativamente menor na intensidade de 70 dB SPL, e não houve presença de onda V na orelha esquerda em 40 dB SPL. Não houveram diferenças significativas nas latências dos interpicos entre as orelhas direita e esquerda, com polaridade condensada e rarefeita. Os valores das medianas das amplitudes I, III e V com 90 dB SPL em compressão e rarefação, não diferiram estatisticamente. Concluiu-se que o nível de resposta mínimo se encontrou entre 40 dB SPL e 80 dB SPL. / The Brainstem Auditory Evoked Potential (BAEP) capture and record the electrical activity of the auditory system, from the cochlea to the brainstem. The Brazil is still little used, and in the South of the country is not yet done in animals. The objective of this study was to identify the absolute values of latency, interpeaks, amplitudes, compare the polarities of compression and rarefaction and to know the auditory threshold in eleven healthy beagle dogs. The dogs underwent physical and neurological examination and were sedated and submitted to otoscopy and Brainstem Auditory Evoked Potential (BAEP). Surface electrodes and insertion headphones were used, the stimulus used was the click with bilateral stimulation. The test was started with 90 dB SPL intensity with condensed polarity. Further research was conducted on 90 dB SPL with rarefied polarity. After that, the test was performed with sequential reductions of 10 dB SPL intensity, and all the research for the auditory thresholds was done with condensed polarity. The interpretation of BAEP was performed by the evaluation of waves I, III and IV, by the identification of the absolute and interpeak latencies, auditory threshold research and comparison between polarities. In wave I latency with a rarefied polarity of 90 dB SPL, the mean absolute values of wave I latency were significantly higher in the left ear (p = 0.037*). Data on absolute V wave latency showed that, in the right ear, the latency was significantly lower in the intensity of 70 dB SPL, and there was no presence of V wave in the left ear in 40 dB SPL. There were no statistically significant differences in the interpeak latencies between the right and left ears, with condensed and rarefied polarity. The values of the medians of amplitudes I, III and V with 90 dB SPL in compression and rarefaction did not differ statistically. The minimum response level was found between 40 dB SPL and 80 dB SPL.
49

Análise dos níveis de pressão sonora produzidos pelos equipamentos odontológicos e sua relação com a ocorrência de alterações auditivas em cirurgiões-dentistas

Januário, Ana Cláudia January 2000 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia de Produção. / Made available in DSpace on 2013-07-15T21:36:03Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T16:01:57Z : No. of bitstreams: 1 185218.pdf: 36690667 bytes, checksum: afba2aae57488aa92adcf81d502ceb62 (MD5) / Provavelmente a grande maioria, se não todas, as pessoas já se submeteu à experiência de aguardar atendimento odontológico na sala de espera de um consultório dentário. Ao ouvir o som produzido pelos equipamentos dentários sentem um certo desconforto e por que não dizer medo, não do barulho em si, mas pela estreita relação deste com a sensação dolorosa. O que as pessoas não se dão conta, incluindo os próprios cirurgiões - dentistas é do perigo que o temido "barulhinho das brocas dentárias", representa à integridade física das pessoas que a ele se expõem. A presente pesquisa revela dados importantíssimos, que indicam a presença de alterações irreparáveis à saúde de cirurgiões - dentistas, principalmente, ao sentido da audição, que levam a crer na relação destes, com a exposição aos elevados níveis de pressão sonora- NPS dB(A) produzidos pelos equipamentos odontológicos. O estudo demonstra que, os níveis de ruído produzido pelos equipamentos odontológicos observados sugerem, um ambiente de risco aos cirurgiões dentistas, onde 16% da população atingida apresentou alguma alteração auditiva permanente e 64% dos examinados apresentaram alteração significativa do limiar auditivo no exame realizado sem repouso acústico, ou melhor, após a jornada de trabalho e apenas 20 % dos dentistas não apresentaram modificação de limiar auditivo após a exposição ao ruído dos equipamentos dentários.
50

Perfil audiológico de adultos com e sem hipertensão arterial / Audiological profile of adults with and without arterial hypertension

Mariana Aparecida Soares 16 May 2014 (has links)
Introdução: Sabe-se que muitas pessoas sofrem de hipertensão arterial sistêmica (HAS) e indivíduos cada vez mais jovens estão apresentando este quadro. A HAS pode causar várias complicações na saúde geral do indivíduo, em virtude do comprometimento da circulação sanguínea, o que pode afetar até mesmo o sistema auditivo. Porém, os estudos encontrados na literatura, até o momento, são bastante controversos quanto à influência ou não da HAS no sistema auditivo periférico. Objetivos: Verificar se existe influência da hipertensão arterial no sistema auditivo periférico, por meio dos achados na audiometria de altas frequências, nas emissões otoacústicas transientes e produto de distorção, comparando grupos de indivíduos normoouvintes pela audiometria convencional, com e sem HAS; e identificar se alguma das variáveis referentes às avaliações realizadas pode ser utilizada para discriminar os indivíduos nos grupos com ou sem HAS. Método: Participaram deste estudo 40 sujeitos de 30 a 50 anos, divididos em grupos com e sem hipertensão arterial. Todos os indivíduos foram submetidos à meatoscopia, imitanciometria, audiometria tonal nas frequências de 250 Hz a 16000 Hz, logoaudiometria, emissões otoacústicas evocadas transientes e emissões otoacústicas produto de distorção. Resultados: Não foi observada diferença estatisticamente significante entre os grupos com e sem HAS na audiometria convencional e em altas frequências. Para as emissões otoacústicas evocados por estímulo transiente, houve tendência à diferença estatisticamente significante, com as respostas do grupo com HAS piores que do grupo sem HAS. Já as emissões otoacústicas produto de distorção, nas frequências de 1501, 2002 e 3003 Hz, apresentaram diferenças estatisticamente significantes, sendo que o grupo com HAS apresentou amplitudes menores. A análise discriminante mostrou que as variáveis das emissões otoacústicas produto de distorção foram as que melhor discriminaram os indivíduos com e sem HAS. Conclusão: Nossos achados sugerem presença de disfunção coclear em indivíduos com hipertensão arterial, uma vez que as respostas das emissões otoacústicas foram piores no grupo com HAS / Introduction: It is widely known that many people have systemic arterial hypertension (SAH) and, currently, the number of young people with such disease is increasing. SAH may cause a wide range of complications in the general health of an individual due to the involvement of blood circulation, which may affect the hearing system. Nevertheless, the reports found in the scientific field are still controversial regarding the influence of SAH on the peripheral auditory system. Purpose: To verify if there is any influence of SAH on the peripheral auditory system, through data from high frequency audiometry, transient-evoked otoacustic emissions and distortion-product otoacoustic emissions and compare such results to groups of typical hearing individuals, with and without SAH, who underwent the pure-tone audiometry test; and also investigate if any variable regarding the hearing assessment may be used to differentiate individuals with and without SAH. Methods: This study counted on 40 individuals aged between 30 and 50 years old, divided into groups with and without SAH. All individuals underwent the following procedures: otoscopy, imitanciometry, pure-tone audiometry in frequencies from 250Hz to 16000 Hz, logoaudiometry, transient-evoked otoacoustic emissions and distortion-product otoacoustic emissions. Results: There was found no significant statistically difference between the groups with and without SAH neither in pure-tone nor high-frequency audiometry. Regarding transient-evoked otoacustic emissions there was a tendency to a significant statistically difference once the SAH group showed lower results. Concerning distortion-product otoacustic emissions there was found significant statistically difference in the following frequencies: 1501, 2002 e 2003 Hz in which the SAH group showed lower results. Discriminant analysis pointed that variables of distortion-product otoacustic emissions best distinguished individuals with and without SAH. Conclusion: Data from this study suggest cochlear dysfunction in individuals with SAH since their results in otoacoustic emissions were lower than in the group with SAH

Page generated in 0.0375 seconds