• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 27
  • 27
  • 27
  • 26
  • 25
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 109
  • 96
  • 50
  • 41
  • 37
  • 27
  • 19
  • 19
  • 18
  • 16
  • 15
  • 15
  • 15
  • 14
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Relação entre a modulação autonômica cardíaca no repouso supino e ortostático e o decremento cronotrópico após o teste de esforço máximo em indivíduos normais

Molina, Guilherme Eckhardt 25 July 2013 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Medicina, Doutorado em Ciências Médicas, Laboratório Cardiovascular, 2013. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-09-17T13:04:16Z No. of bitstreams: 1 2013_GuilhermeEckhardtMolina.pdf: 4819862 bytes, checksum: e63535236f844d504418336c1953fb64 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-10-16T15:10:48Z (GMT) No. of bitstreams: 1 2013_GuilhermeEckhardtMolina.pdf: 4819862 bytes, checksum: e63535236f844d504418336c1953fb64 (MD5) / Made available in DSpace on 2013-10-16T15:10:48Z (GMT). No. of bitstreams: 1 2013_GuilhermeEckhardtMolina.pdf: 4819862 bytes, checksum: e63535236f844d504418336c1953fb64 (MD5) / Introdução: Os mecanismos fisiológicos envolvidos na modulação autonômica cardíaca durante o período de decremento da freqüência cardíaca após o teste de esforço (FCR) é um assunto controverso e pouco explorado, considerando as adaptações cardiovasculares e a análise do risco prognóstico em diversas populações com condições clínicas e funcionais distintas. Objetivos: Correlacionar a FCR com a função autonômica cardíaca obtida na condição de repouso supino e ortostático e com a alteração da modulação autonômica cardíaca obtida por meio da mudança postural ativa da posição supina para a posição ortostática Indivíduos e Métodos: Foram avaliados 31 homens (n=31), adultos e clinicamente normais. A FCR no 1º, 3º e 5º minutos de recuperação após o teste de esforço foi correlacionada com as variáveis obtidas por meio das análises, temporal, espectral, tempo-frequencial e de Poincaré da variabilidade da frequência cardíaca (VFC). A VFC foi obtida por meio do registro curto de 5 minutos nas posições, supina e ortostática. Para realização das análises, utilizou-se a correlação de Spearman no qual foi considerado o nível de significância de 5%. Resultados: Verificou-se a predominância parassimpática na posição supina no repouso. Na posição ortostática, verificou-se a retirada da modulação parassimpática com aumento da modulação simpática. A mediana (quartis) da FCR obtida no 1ºmin de recuperação (26; 20.2-32.5 bpm) não correlacionou-se com a VFC em ambas as posturas, supina e/ou ortostática (p=0.15-0.98) ou com a mudança postural ativa (p=0.07-0.88). A FCR no 3º (61; 56 - 64.7 bpm) e 5º (68; 62-73 bpm) minutos de recuperação não correlacionaram-se com a VFC na posição supina (p=0.05-0.98). A VFC na posição ortostática e o 3º e 5º minutos de recuperação correlacionaram-se inversamente com os índices parassimpáticos (p=0.01-0.04) e diretamente com os índices simpáticos, somente no 5º minuto de recuperação (p=0.04). Na postura ortostática, verificou-se a correlação direta da diminuição dos índices de modulação parassimpática com o 3º e 5º minutos de recuperação (p=0.0009-0.05), e não foi verificada correlação da modificação dos índices simpáticos (p=0.28-0.99) com a recuperação após o esforço. Conclusões: A FCR no 3º e 5º minutos de recuperação após o esforço correlaciona inversamente com os índices parassimpáticos obtidos na posição ortostática na condição de repouso e diretamente com a diminuição da atividade parassimpática associada com a mudança postural, enquanto verificou-se correlação oposta entre a FCR e os índices simpáticos. ______________________________________________________________________________ ABSTRACT / Background: The autonomic modulation of post-exercise heart rate recovery (HRR) is an incompletely explored issue regarding cardiovascular adaptation and prognosis. Objective: To correlate the HRR with autonomic modulation both at rest and on standing up. Methods: HRR at 1, 3 and 5 min following maximal treadmill exercise and 5-min time- and frequency-domain and time-frequency analysis and Poincaré plot - heart rate variability (HRV) in resting supine and standing positions were correlated in 31 healthy young males using Spearman’s correlation, which was considered significant at a p<0.05. Results: Predominantly parasympathetic modulation was observed in the resting supine position. In the orthostatic position, both prominent parasympathetic withdrawal and asympathetic enhancement was observed. The median (quartiles) HRR at 1 min (26; 20.2-32.5 bpm) showed no correlation with HRV in both postures (p=0.15-0.98) or with the changes on standing up (p=0.07-0.88). HRR at 3 min (61; 56-64.7 bpm) and 5 min (68; 62-73 bpm) also no correlated with the supine HRV (p=0.05-0.98). With the orthostatic HRV, the 3 and 5 min HRR inversely correlated with the parasympathetic (p=0.01-0.04) and directly with the sympathetic indices at 5 min only (p=0.04). A direct correlation of HRR with the orthostatic decrease in parasympathetic indices occurred at 3 min and 5 min (p=0.0009-0.05), but no correlation with the change in sympathetic indices was found (p=0.28-0.99). Conclusion: HRR at 3 and 5 min only was inversely correlated with resting orthostatic parasympathetic modulation and directly correlated with the decrease in parasympathetic activity associated with standing up, while opposite correlations were found between HRR and the sympathetic modulation.
2

Sistema de monitoramento e análise da variabilidade de curto prazo da frequência cardíaca fetal /

Ishizava, Osvaldo. January 2016 (has links)
Orientador: Alexandre César Rodrigues da Silva / Coorientador: Aledir Silveira Pereira / Banca: Rodrigo Capobianco Guido / Banca: Guaraci Silveira Garcia / Resumo: O objetivo principal da avaliação fetal anteparto por meio da variabilidade de curto prazo (VCP) da frequência cardíaca fetal (FCF) é auxiliar no monitoramento fetal em gestações normais e de risco, evitando maior número de morte-fetal, atuando de forma preventiva evitando que gestantes e fetos sofram durante a gestação. O Sistema de Monitoramento e Análise da Variabilidade a Curto Prazo da Frequência Cardíaca Fetal proposto é um método não invasivo oferecendo recursos acessíveis para que especialistas obtenham mais informações, para que gestantes normais e com gravidez de alto risco tenham maior segurança em suas gestações. Poderá atuar de forma remota, preventiva e acessível a todas gestantes, eliminando as dificuldades oferecidas pelo estresse da vida moderna causados pela locomoção até as clínicas e hospitais, eliminando também o risco para sua saúde com a circulação em ambientes hospitalares para realização de exames cardiotocográficos durante o anteparto. Atualmente vivemos em mundo globalizado onde os recursos de comunicação sem fio são acessíveis, rápidos e seguros. O sistema proposto poderá ser implantado em dispositivos de processamento remoto, disponibilizando para obstetras e ginecologistas a análise de exames da FCF e VCP em tempo real, sem a necessidade da remoção da gestante do estado de repouso no conforto do lar para a clínicas ou hospitais. Ampliando ainda, as possibilidades de gestações de sucesso com a redução dos procedimentos atuais causando deslocamentos e estresse, reduz-se também as possibilidades que estes transtornos causem maior sofrimento fetal / Abstract: The main objective of fetal assessment antepartum through short-term variability (STV) of the fetal heart rate (FHR) is to assist in fetal monitoring in normal and risk pregnancies, avoiding more fetal deaths, acting preventively in preventing pregnant women and fetuses to suffer during pregnancy. The proposed Fetal Heart Rate Short-term Variability Analysis and Monitoring System is a noninvasivemethod, which offers accessible resources for specialists to get more information so that healthy pregnant women and high-risk pregnancies have security increased in their pregnancies. It may act in a remote, preventive and acesssible way to all pregnant women, by eliminating the difficulties offered by the stress of modern life caused by transporting to clinics and hospitals, also eliminating the risk to their health with the circulation in hospitals for performing cardiotocography tests during the antepartum. As we have currently lived in a globalized world, where wireless communication resources are cheap, fast and safe, the proposed system can be deployed in remote processing devices, providing obstetricians and gynecologists examination analysis of FHR and STV in real time without the need of pregnant women to leave the resting state in the comfort of their home, to go to clinics or hospitals and also expanding the chances of successful pregnancies by reducing current procedures which cause displacement and stress as well as reducing up the possibilities of these disorders to cause increased fetal distress / Mestre
3

Avaliação eletrocardiográfica em fêmeas prenhes, fetos e neonatos equinos da raça Paint Horse

Alfonso, Angélica. January 2015 (has links)
Orientador: Maria Lucia Gomes Lourenço / Resumo: Atualmente, observamos uma maior necessidade de uma assistência adequada tanto pré-natal, quanto neonatal com o intuito de se reduzir a mortalidade de recém-nascidos, principalmente de animais com elevado valor genético e zootécnico. O exame eletrocardiográfico pode se revelar como ferramenta importante em neonatologia equina, visto que permite a determinação da frequência cardíaca, do ritmo cardíaco, distúrbios de condução e obtenção de índices de variabilidade da frequência cardíaca. Este trabalho visou retratar o comportamento dos parâmetros eletrocardiográficos em éguas prenhes, fetos e potros neonatos, com o intuito de determinar se a frequência cardíaca (FC) e os índices de variabilidade da frequência cardíaca (VFC) materna e fetal são indicativos da proximidade do parto; determinar viabilidade fetal e neonatal, e descrever a evolução do desenvolvimento do sistema nervoso autônomo durante este período, bem como detectar as particularidades na dinâmica eletrocardiográfica durante o período neonatal nos equinos da raça Paint Horse. Foram avaliados 20 éguas, 20 fetos e 20 potros cujos exames eletrocardiográficos maternos e fetais foram realizados entre 15 e sete dias pré-parto. Quanto ao eletrocardiograma neonatal, os momentos a serem avaliados foram: ao nascimento, quatro, oito, 12, 16, 20, 24, 36 e 48 horas pós parto e posteriormente uma vez por semana até os 35 dias de idade. Os resultados obtidos da VFC fetal e neonatal do presente estudo, quando comparados aos materno... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Currently, we observe an increased need for adequate assistance both prenatal, neonatal as aiming to reduce mortality of newborns, mainly animals with high genetic and livestock value. The electrocardiogram can represent an important tool in equine neonatology, since this test allows the determination of heart rate, cardiac rhythm, disturbances of conduction and obtaining indexes of heart rate variability. This study aimed to represent the behavior of electrocardiographic parameters in mares, fetuses and newborn foals, in order to determine whether the heart rate (HR) and indexes of heart rate variability (HRV) of the mare and the fetuses are indicative of birth proximity; to determine the fetal and neonatal viability, to describe the evolution of the development of the autonomic nervous system during this period, and to detect the particulars in the electrocardiographic dynamic during the neonatal period in foals of Paint Horse breed. There were 20 mares, 20 fetuses and 20 newborn foals, whose maternal and fetal electrocardiographic examinations were performed at, approximately, 15 and 07 days prepartum. The neonatal electrocardiogram occurred: at birth, four, eight, 12, 16, 20, 24, 36 and 48 hours after delivery and thereafter once per week until 35 days of age. The results of fetal and neonatal HRV of the present study, when compared to maternal indicated the parasympathetic dominance during fetal and neonatal sympathetic dominance during to the third and / or fourth weeks... (Complete abstract click electronic access below) / Mestre
4

Efeito da duração do intervalo em saltos verticais : relações entre trabalho realizado e duração até a exaustão /

Pereira, Gleber. January 2004 (has links)
Orientador: Eduardo Kokubun / Banca: André Luiz Félix Rodacki / Banca: Emerson Franchini / Resumo: O objetivo deste estudo foi verificar se o modelo da potência crítica se ajusta para saltos verticais. Após a determinação da altura máxima de salto vertical, dez participantes realizaram saltos verticais, com movimento semelhante ao bloqueio no voleibol com contra-movimento, até a exaustão em três intervalos de tempo diferentes (entre 4 e 7 s). No 5º, 6º e 7º dias foram executados saltos verticais na intensidade correspondente ao intervalo crítico ( tc) e 5% abaixo e acima. O teste era interrompido quando o participante não pôde mais alcançar uma altura pré-estabelecida por três vezes consecutivas, e em seguida medida a concentração de lactato sangüíneo, freqüência cardíaca, tempo até a exaustão e número de saltos verticais realizados. Uma plataforma de força foi utilizada para captar a força de reação do solo vertical, possibilitando posteriormente o cálculo do impulso concêntrico e da altura do salto vertical. Foi assumido que o trabalho externo total para elevar o centro de massa nos saltos verticais poderia ser expresso pela somatória dos impulsos concêntricos ( I) ou pelo número de saltos verticais multiplicados pela altura do salto vertical pré-fixada ( H). Os dados foram ajustados com os procedimentos de regressão linear e não linear para resolver as equações do modelo da potência crítica (PCrit) e determinar as estimativas da PCrit, da capacidade de trabalho anaeróbio e do tc para cada modelo matemático (não linear potência-tempo, linear trabalho-tempo e linear potência-1/tempo) e método ( I e H). Os resultados indicaram que (a)as sessões utilizadas para determinar o tc foram exaustivas e similares; (b)houve relação entre trabalho externo realizado em saltos verticais medido pela plataforma de força e pelo número de saltos verticais em diferentes intervalos com a duração do exercício até a exaustão... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this study was to verify if the critical power (CP) model fits to vertical jump. The maximum jump height of ten subjects were determined. During following days, the subjects performed vertical jumps until exhaustion, simulating volleyball block with countermovement, with three different time intervals between jumps (between 4 and 7 seconds). In 5º, 6º and 7º days the subjects performed jumps at ?tc (critical interval) and 5% below and above it, until they could not reach pre-established height for three consecutive times. Blood lactate, heart rate, time to exhaustion and number of jump performed at the end of exercise were measured. The concentric impulse and jump height were measured by vertical ground reaction force at force platform. It was assumed that the total external work to elevate body center of mass, would be expressed as the somatory of the concentric impulses ( I) or the total jumps performed multiplied by the pre-established jump height ( H). The data were fitted to the three mathematics equations of the CP model (non-linear power-time, linear work-time and linear power-1/time). The results indicated that (a)the sessions used to determine tc were exhaustive and similar; (b)there was relationship between the total external work in vertical jump measured in both methods (force platform and number of vertical jump performed under different intervals) with the time to exhaustion; (c)the tc values estimated by the two methods were similar and; (d)the physiologic of responses to vertical jumps performed at tc intensity were similar to that observed in continuous exercise performed at CP intensity. Therefore, it was concluded that the critical power model fits to vertical jump. / Mestre
5

Investigação dos efeitos de anestesia sobre a variabilidade cardíaca

Okida, Sérgio January 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2012 / Made available in DSpace on 2013-06-26T00:48:33Z (GMT). No. of bitstreams: 1 312308.pdf: 2734359 bytes, checksum: 6b34b2bbf365bac46a50fbea30e60ae8 (MD5) / Dada a grande variabilidade da resposta fisiológica, um determinado volume de anestésico pode ser insuficiente para determinado indivíduo e ser excessivo para outro. Estudos realizados em vários países relatam uma taxa de 0,1% a 0,2% de retomada da consciência com lembranças de eventos durante cirurgia sob anestesia geral. O despertar peroperatório pode provocar síndrome pós-traumática, com graves sequelas psicológicas para o paciente. Existem também, os casos opostos, onde o excesso de anestésico, tardiamente percebido, acarreta dano cerebral. Pacientes excessivamente anestesiados demoram mais para receber alta, aumentando assim, o custo da internação hospitalar. Um crescente número de estudos vem sendo realizado para avaliar as alterações na variabilidade do ritmo cardíaco (VRC) durante anestesia. Estes estudos utilizam diferentes anestésicos, procedimentos, métodos de processamento e análise de sinais. A finalidade é obter índices que possam determinar o nível de profundidade anestésica. No entanto, os resultados obtidos ainda não são conclusivos. Este trabalho investiga a VRC em 11 pacientes anestesiados com o nível de profundidade anestésica monitorada por meio do índice BIS. Para tal, utiliza medidas de defasamento entre a série RR e volume pulmonar, bem como realiza modelamento multivariáveis da VRC. A partir dos resultados obtidos para esta pequena amostra, observou-se que a estabilidade do defasamento indica que o sistema nervoso autônomo não se encontra bloqueado. A extensão deste estudo para um maior número de pacientes pode permitir que a medida de defasamento seja incorporada a monitores de profundidade anestésica como um índice auxiliar de analgesia.<br> / Abstract : Due to the large variability of physiological responses, a given quantity of anesthetic may be insufficient for some individuals and ex-cessive for others. During surgery under general anesthesia, studies carried out in several countries reported a rate of consciousness recov-ery, in which the patients had memories of the events, between 0.1% and 0.2%. The per-operative wakeup may cause post-traumatic syn-drome with serious psychological consequences for the patients. There are also opposite cases when the excess of anesthetic causes brain dam-ages. Patients who receive anesthetics in excess remain longer under medical care, increasing the hospitalization costs. Recent studies have assessed changes of the heart rate variability (HRV) during anesthesia. These works employed different anesthetics, procedures and methods for signal processing and data analysis. Their purpose was to obtain indexes that could determine the level of anesthet-ic depth. However, the results obtained so far are not conclusive. This work investigated the HRV of 11 patients who had their an-esthetic depth monitored by the BIS index. Phase shift measurements between the RR and lung volume waveform and multivariate modeling of the HRV were carried out. From the obtained results for this small number of subjects, it was found that the phase shift stability between the RR and lung volume waveform points out that the autonomic nerv-ous system is not blocked. The extension of this study to a larger num-ber of patients may allow the monitoring of such phase shift to be used as an anesthetic index of analgesia.
6

Efeitos das catecolaminas sobre a reposição volêmica com solução fisiológica. Repercussão sobre a variabilidade da frequência cardíaca de coelhos submetidos à hemorragia: estudo por análise espectral

Moraes, José Mariano Soares de [UNESP] 01 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-01Bitstream added on 2014-06-13T18:46:38Z : No. of bitstreams: 1 moraes_jms_dr_botfm.pdf: 700799 bytes, checksum: fc4d9acf6b612dcd147bd547fbffdcbe (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Efeitos das catecolaminas sobre a reposi çãoo vol êmica com solu ção fisiol ógica. Repercuss ão sobre a variabilidade da frequ ência card íaca de coelhos submetidos à hemorragia. Estudo por an álise espectral. Verificar os efeitos de diferentes catecolaminas sobre a expans ão volê mica e sobre o sistema nervoso autonô mico em coelhos submetidos à hemorragia. Foram estudados 24 coelhos, submetidos à hemorragia (25% da volemia), distribu ídos aleatoriamente em quatro grupos experimentais, conforme o tipo de reposi ção vol êmica realizada. Grupo HEMO - reposi ção com o pr óprio sangue com volume igual ao retirado. Grupo SF - reposiçã o com solu çã o fisiol ógica (SF) em volume correspondente a tr ês vezes o volume de sangue retirado. Grupo ISP - reposi ção com SF em volume correspondente a tr ês vezes o volume de sangue retirado, e Isoprenalina na dose de 0,1 g.kg-1.min-1, e Grupo FNL – reposi çã o com SF em volume correspondente a tr ês vezes o volume de sangue retirado, e Fenilefrina na dose de 3,0 g.kg-1.min-1. Durante o experimento, foram monitoradas as seguintes vari áveis: hemató crito (para avalia çã o da retençã o intravascular da soluçã o cristaloide), diurese, press ção venosa central (PVC) e pressão arterial mé dia (PAM). Tamb ém foi feito o registro cont ínuo da onda da press ão arterial donde analisando-se o pico sist ólico aferiu-se a variabilidade da frequ ência card íaca (VFC) nos per íodos correspondentes à: basal, hemorr ágico, infus ção de catecolaminas e controle pó s-reposi ção vol êmica. A reposi çã o com SF associado a catecolaminas α ou β agonistas n ão demonstrou diferen ças no que tange reten ção intravascular comparando-se reposi çã o isolada com SF. A diurese total foi maior no grupo FNL quando comparando-se... / The effect of catecholamines over volemic reposition with saline solution and its effects on the heart rate variability on rabbits subjected to hemorrhage. Research through Spectral Analysis. To check the effects of different catecholamines on the volemic expansion and on the autonomic nervous system of rabbits subjected to hemorrhage. 24 rabbits were studied, subjected to hemorrhage (25% volemia), randomly distributed in four experimental groups, according to the type of volemic reposition done. HEMO Group: Reposition administered with the animal’s own blood, in the same amount of blood taken out. Saline Solution (SS) Group: Reposition with SS, three times the amount of blood withdrawn. Isoprenaline (ISP) Group: Reposition with SS, three times the amount of blood taken out, and Isoprenaline at 0,1 g.kg-1.min-1; and Phenylephrine (PHN) Group: Reposition with SS three times the amount of blood withdrawn, and Phenylephrine at 3,0 g.kg-1.min- 1. During the experiment, the following variables were monitored: hematocrit (to evaluate intravascular retention of the crystalloid solution), diuresis, central venous pressure and medium blood pressure. The blood pressure curve was also checked and by examining the systolic peak, the heart rate variability was verified during these different stages: basal, hemorrhagic, catecholamine infusion and post volemic reposition control. The reposition done with SS mixed in agonist α or β catecholamine did not demonstrate differences in intravascular retention, when comparing to isolated reposition with SS. Total diuresis was bigger in the PHN Group than in the HEMO Group. The Central Venous Pressure was significantly higher in the group where volemic reposition with SS was administered, when comparing it to the group where PHN was used. The HRV research showed that the physiological response of the autonomic nervous system in the PHN group... (Complete abstract click electronic access below)
7

Função autonômica cardíaca e desempenho no exercício resistido em indivíduos com doença de Parkinson

Santos, Tácio Rodrigues da Silva 16 June 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Educação Física, Programa de Pós-Graduação Strictu-Sensu em Educação Física, 2014. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2014-09-04T13:45:43Z No. of bitstreams: 1 2014_TacioRodriguesSilvaSantos.pdf: 3980570 bytes, checksum: 2e3a60703d705fbea99b8c9364246e02 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-09-05T13:50:48Z (GMT) No. of bitstreams: 1 2014_TacioRodriguesSilvaSantos.pdf: 3980570 bytes, checksum: 2e3a60703d705fbea99b8c9364246e02 (MD5) / Made available in DSpace on 2014-09-05T13:50:48Z (GMT). No. of bitstreams: 1 2014_TacioRodriguesSilvaSantos.pdf: 3980570 bytes, checksum: 2e3a60703d705fbea99b8c9364246e02 (MD5) / A disautonomia é um dos sintomas não motores mais incapacitantes da doença de Parkinson, pois incide na função autonômica cardíaca, resultando em falência da atividade simpática. Indivíduos com doença de Parkinson que apresentam falência da atividade simpática alcançam um menor desempenho no exercício físico, que é parte integrante do tratamento desta patologia. Entretanto, em nosso conhecimento, esta questão foi investigada apenas no exercício aeróbio. Como o exercício resistido é a classe de exercício físico que proporciona mais benefícios a indivíduos com doença de Parkinson, o objetivo do presente estudo foi analisar a função autonômica e o desempenho no exercício resistido em indivíduos com doença de Parkinson. Para tanto, 14 indivíduos com doença de Parkinson foram submetidos a uma avaliação da função autonômica cardíaca pela variabilidade da frequência cardíaca e divididos em simpaticotônicos (n = 9) e vagotônicos (n = 5). Posteriormente, foi analisada a ocorrência de hipotensão ortostática em repouso e após o exercício resistido; e o desempenho no exercício resistido (três séries de 12 a 15 repetições no exercício pressão de pernas). O grupo simpaticotônico apresentou hipotensão ortostática na pressão arterial sistólica em repouso (118 mmHg vs. 98 mmHg; p = 0,02), e o grupo vagotônico apresentou hipotensão ortostática na pressão arterial diastólica após o exercício resistido (86 mmHg vs. 73 mmHg; p = 0,03). O grupo simpaticotônico realizou um volume de treino maior que o grupo vagotônico (2.250 kg vs. 900 kg; p = 0,02) mesmo sem haver diferença entre a Percepção Subjetiva de Esforço dos grupos (8 pontos vs. 8 pontos; p = 0,47) ou entre as características demográficas e clinimétricas. Neste sentido, podemos concluir que indivíduos com doença de Parkinson que apresentam falência da atividade simpática alcançam um menor desempenho no exercício resistido em relação àqueles que não apresentam este quadro. ______________________________________________________________________________ ABSTRACT / Dysautonomia is one of the most prejudicial non motor symptoms of Parkinson's disease because it affects the cardiac autonomic function and results in sympathetic failure. Individuals with Parkinson's disease with sympathetic failure showed a worst performance during the physical exercise, which is part of the treatment. In our knowledge, this question was investigated only in the aerobic exercise. As the resistance exercise is the type of physical exercise that promotes more benefits to individuals with Parkinson's disease, the purpose of the present study was to analyze the cardiac autonomic function and the performance in resistance exercise in individuals with Parkinson's disease. A group of 14 individuals with Parkinson's disease was submitted to a cardiac autonomic function evaluation by the heart rate variability and was divided into sympathetic group (n = 9) and parasympathetic group (n = 5). The orthostatic hypotension occurrence was analyzed at rest and after the resistance exercise. The performance in resistance exercise was also analyzed (three sets of 12 to 15 repetitions in the leg press exercise). The sympathetic group had orthostatic hypotension in systolic blood pressure at rest (118 mmHg vs. 98 mmHg; p = 0,02), and the parasympathetic group had orthostatic hypotension after the resistance exercise (86 mmHg vs. 73 mmHg; p = 0,03). The sympathetic group realized a training volume greater than parasympathetic group (2.250 kg vs. 900 kg; p = 0,02), but there was no difference between the groups for perceived exertion (8 points vs. 8 points; p = 0,47) and for the demographic and the clinimetric characteristics. In conclusion, individuals with Parkinson's disease with sympathetic failure showed a worst performance in resistance exercise in relation with the no sympathetic failure ones.
8

Estudo do controle autonomico da frequencia cardiaca em ciclistas e sedentarios

Martinelli, Fabiana Spina 07 June 2001 (has links)
Orientador: Lourenço Gallo Junior / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-07-28T11:15:22Z (GMT). No. of bitstreams: 1 Martinelli_FabianaSpina_D.pdf: 7310467 bytes, checksum: 1ca766b7be62f62653cdf73036819d12 (MD5) Previous issue date: 2001 / Resumo: O principal objetivo deste trabalho foi estudar o controle autonômico da freqüência cardíaca (FC) em indivíduos com diferentes graus de capacidade física aeróbia, durante as seguintes condições: repouso, Manobra de Valsalva (MV), Arritmia Sinusal Respiratória (ASR) e Manobra Postural Passiva (MPP). Participaram deste estudo transversal um grupo de indivíduos sedentários (grupo S), que não praticavam atividade física regular há pelo menos 1 ano e, um grupo de atletas ciclistas (grupo C), que praticavam esta modalidade há pelo menos 1 ano. Para avaliação da capacidade aeróbia e do controle autonômico da FC foram realizados os seguintes procedimentos: teste de esforço físico dinâmico, Manobra de Valsalva, Arritmia Sinusal Respiratória e Manobra Postural Passiva. Nas condições de repouso e durante a MPP foi também realizado o estudo da variabilidade da FC (VFC) nos domínios do tempo (DT) e da freqüência (DF). O grupo C apresentou capacidade aeróbia superior ao grupo S, expressa por maiores valores do consumo de oxigênio e potência de esforço, no limiar de anaerobiose e no pico do esforço (p<O,O5). A freqüência cardíaca de repouso foi menor nos atletas em relação aos sedentários (p<O,O5) o que parece ter sido causado pela diminuição da freqüência cardíaca intrínseca. Os valores da Taxa de Valsalva e da Diferença de Valsalva não foram estatisticamente diferentes entre os grupos, sugerindo que o TFA não promoveu adaptações autonômicas cardiovasculares significativas a ponto de serem observadas durante a manobra de Valsalva. Apesar da Arritmia Sinusal Respiratória ter sido maior nos sedentários, os demais dados deste trabalho não permitem afirmar a existência de uma maior atividade vagal neste grupo. Este resultado pode ter sido causado por problemas metodológicos e de planejamento experimental. Os atletas apresentaram menores valores de FC até o vigésimo minuto da MPP quando comparados com o grupo de sedentários, o que parece estar relacionado à redução da freqüência cardíaca intrínseca. As variações da FC durante esta manobra, calculadas pelos deltas de FC, não foram estatisticamente diferentes entre os grupos. A VFC em repouso e durante a Manobra Postural Passiva não foi estatisticamente diferente entre os sedentários e atletas, indicando que o TFA não alterou quantitativamente as atividades autonômicas simpática e vagal sobre o coração / Abstract: The main purpose of this work was to study the heart rate (HR) control in subjects with different aerobic capacities, during the following situations: resting, Valsalva Maneuver (VM), Respiratory 8inus Arrhythmia (R8A) and Head-up Tilt (HUT). Participated of this cross-sectional study a group of sedentary subjects (8 group), that didn't practice any regular physical activity for at least 1 year, and a group of cyclist athletes (C group), engaged in this modality for at least 1 year. The following tests were realized to evaluate the aerobic capacity and the HR autonomic control of the groups: dynamic exerci se test, Valsalva Maneuver (VM), Respiratory 8inus Arrhythmia (R8A) and Head-up Tilt (HUT). During rest and HUT the heart rate variability (HRV) was analyzed in the time (TD) and frequency (FD) domains. The C group presented higher aerobic capacity compared with 8 group, expressed by higher values of oxygen uptake and work load, at anaerobic threshold and exercise peak conditions (p<O.O5). The resting HR was lower in athletes compared with nonathletes (p<O.O5), which seems to be related to intrinsic HR reduction. The Valsalva Ratio and the Valsalva Difference values were not statistically different between groups, suggesting that aerobic physical training didn't induce significative cardiovascular autonomic adaptations which could be observed during the Valsalva maneuver. Besides the higher Respiratory Sinus Arrhythmia in the S group (p<O.O5), the other results presented in this work suggest that this group doesn't have higher vagal activity compared with C group. This result could be caused by methodological and experimental problems. The athletes presented lower values of HR until the 20th minute of HUT when compared with S group, which seems to be related to the athletes' lower intrinsic HR. The HR variations during this maneuver, calculated by HR deltas, were not statistically significant when groups were compared. The HRV during rest and HUT weren't statistically different between athletes and sedentary subjects, suggesting that aerobic physical training didn't change quantitatively the sympathetic and parasympathetic activities on the sinus node / Doutorado / Fisiologia / Doutor em Biologia Funcional e Molecular
9

O estudo dos disturbios do ritmo cardiaco na hipertrofia ventricular esquerda secundaria a hipertensão arterial sistemica

Pinho, Claudio 15 December 1992 (has links)
Orientador : Luiz A. K. Bittencourt / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-17T10:56:25Z (GMT). No. of bitstreams: 1 Pinho_Claudio_D.pdf: 5614304 bytes, checksum: d37bb769a80a1bb157b42c18a66a4873 (MD5) Previous issue date: 1992 / Resumo: Foram estudados os distúrbios do ritmo cardíaco em setenta e dois pacientes com hipertensão arterial sistêmico, separados por sexo e pela presença ou ausência de hiperdrofia ventricular esquerda ao ecocordiograma bidimensional. Os dados obtidos do holter revelaram que a ocorrência de um número superior a quinhentas extrossístoles nas vinte e quatro horas ou atividade repetitiva ventricular ou taquicardia ventricular, estiveram relacionadas à presença de hipertrofia ventricular esquerda. A positividade do eletrocardiograma de altas resolução (análise temporal) e presença de taquicardia ventricular não sustentada teve forte correlação no grupo de pacientes do sexo masculino com hipertensão arterial sistêmica e hipertrofia ventricular esquerda; a análise espectrotemporal foi concordante com esse achado. É feita uma proposta para a explicação do mecanismo arritmogênico da hipertrofia ventricular esquerda bem como de um algoritmo de avaliação e conduta nos pacientes hipertensos com hipertrofia ventricular esquerda e distúrbios do ritmo cardíaco / Abstract: Not informed / Doutorado / Doutor em Clínica Médica
10

Efeitos do treinamento do método Pilates na modulação autonômica da frequência cardíaca e na composição corporal : um ensaio clínico randomizado e uma revisão sistemática com meta-análise /

Cavina, Allysiê Priscilla de Souza. January 2019 (has links)
Orientador: Franciele Marques Vanderlei / Banca: Diego Giulliano Destro Christófaro / Banca: Ana Clara Campagnolo Gonçalves Toledo / Resumo: The objective of the present dissertation was to verify the effect of the training of the Pilates method on the autonomic modulation of heart rate, besides presenting a systematic review with meta-analysis on the effectiveness of the Pilates method in body composition. Methods: The clinical trial consisted of 47 healthy men aged 18 to 35 years were analyzed. Participants were divided into two groups: Pilates group (GP) and control group (CG). The GP performed 36 sessions of the Pilates method for approximately 60 minutes each session and often three times a week. For the Systematic Review, the studies were selected using seven databases (MEDLINE, EMBASE, SportDiscus, PEDro, SciELO, CINAHAL and The Cochrane Library), from the oldest record of each database until the 28th of March of 2018. Results: In the clinical trial, there was an interaction of moments versus groups for the GP in the SDNN indices (p = 0.021), LF [ms2] (p = 0.016) and SD2 (p = 0.011) in addition, there was a statistically significant (p <0.05) increase in GP delta values when compared to CG for the overall HRV indices. Twelve eligible studies were chosen for the systematic review. The main findings of this review were that, when analyzed without distinction of population, the Pilates method was more effective than the conditions of comparison only for abdominal circumference (seven studies, n = 295; SMD = 0.24, 95% CI, 01, 0.48], p = 0.04, I 2 = 0%,). In the exploratory analysis for the elderly population, ... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre

Page generated in 0.0897 seconds