Spelling suggestions: "subject:"bicarbonate dde sócio"" "subject:"bicarbonate dde audio""
21 |
INTERAÇÃO DA ALCALINIDADE E DENSIDADE DE ESTOCAGEM EM JUVENIS DE JUNDIÁ Rhamdia quelen (HEPTAPTERIDAE) / INTERACTION OF ALCALINITY AND STOCKING DENSITY FOR SILVER CATFISH Rhamdia quelen JUVENILES (HEPTAPTERIDAE)Andrade, Luciana Segura de 15 August 2005 (has links)
To evaluate interaction of water alkalinity and stocking density on body ionic levels, survival, growth and behavior of silver catfish, Rhamdia quelen, juveniles, a short-term experiment (96 h) analyzed the effect of three alkalinity levels (30, 80 and 130 mg/L CaCO3) and four stocking densities (4, 8, 16, and 24 g/L). In addition, a growth experiment of 30 days verified the effect of three stocking densities (4, 8, 16 g/L) and the same alkalinity levels. Survival and body ionic levels were not significantly affected in the short-term experiment, but after 30 days survival was significantly reduced in the group maintained at the stocking density of 16 g/L and 30 mg/L CaCO3. However, this treatment provided higher weight and specific growth rate compared to the treatment with the highest alkalinity and the same stocking density. The time of capture of the food, in both experiments, was faster in the treatments of high stocking density. In the short-term experiment fish remained mainly in the bottom, and the reduction of stocking density increased swimming speed. The color of the animals was significantly clearer in the lowest densities of the growth experiment. Agonistic side behaviors prevailed in the lowest alkalinities of the stocking density of 8 g/L, and cannibalism occurred only in the stocking density of 8 g/L and alkalinity of 130 mg/L CaCO3 of the growth experiment. The stocking density of 16 g/L and alkalinity of 80 mg/L CaCO3 seems to be the most appropriate for silver catfish juveniles growth in these experimental conditions. / Com o objetivo de avaliar a interação da alcalinidade da água com diferentes densidades de estocagem sobre os níveis iônicos corporais, sobrevivência, crescimento e comportamento de juvenis de jundiá, Rhamdia quelen, delineou-se um experimento de curta duração (96 h) com três níveis de alcalinidade (30, 80 e 130 mg/L CaCO3) e quatro densidades de estocagem (4, 8, 16 e 24 g/L). Além disso, em um experimento de crescimento (30 dias) testou-se três densidades de estocagem (4, 8, 16 g/L) e as mesmas alcalinidades. A sobrevivência e os níveis iônicos corporais não foram afetados no experimento de curta duração, mas após 30 dias a sobrevivência foi reduzida no tratamento de maior densidade e menor alcalinidade. Este mesmo tratamento foi o que obteve melhores resultados de peso e taxa de crescimento específico em relação à maior alcalinidade da mesma densidade. O tempo de captura do alimento, em ambos experimentos, foi mais curto nos tratamentos de maior densidade. No experimento de curta duração os peixes se concentravam mais no fundo à medida que se diminuía a densidade de estocagem e com o aumento desta aumentou a velocidade de natação. A coloração dos animais foi significativamente mais clara nas menores densidades do experimento de crescimento. Confrontos laterais predominaram nas menores alcalinidades da densidade de 8 g/L, canibalismos ocorreram apenas na densidade de 8 g/L e alcalinidade de 130 mg/L CaCO3 do experimento de crescimento. A utilização da densidade de estocagem de 16 g/L e alcalinidade de 80 mg/L CaCO3 é a mais adequada para o cultivo de juvenis de jundiá nestas condições experimentais.
|
22 |
Hidratação com bicarbonato de sódio na prevenção de nefropatia induzida por contraste : estudo clínico multicêntricoGomes, Vitor Osório January 2009 (has links)
Introdução: Nefropatia induzida por contraste (NIC) está associada a piores desfechos intra-hospitalar e a longo prazo. Estudos recentes sugerem que hidratação com bicarbonato de sódio possa ser útil na sua prevenção; no entanto, essa medida de prevenção de NIC não foi, ainda, avaliada em pacientes diabéticos. Método: Subanálise de um estudo multicêntrico envolvendo 301 pacientes com creatinina sérica ≥ 1,2 mg/dl ou depuração de creatinina endógena (DCE) < 50 ml/min submetidos a cineangiocoronariografia ou angioplastia coronária, randomizados para receber hidratação com bicarbonato de sódio ou solução salina (soro fisiológico – SF) a 0,9%. Todos os procedimentos foram realizados com contraste iônico de baixa osmolaridade. Os desfechos avaliados foram incidência de NIC (definida como aumento de 0,5 mg/dl) e variação da creatinina e da DCE em 48 horas após o procedimento. Da totalidade de pacientes, 87 tinham diabetes melito e foram incluídos nesse subestudo. Resultados: Não houve diferença entre os grupos em relação a características demográficas, volume de contraste e níveis basais de creatinina e DCE. Entre os pacientes avaliados, 8 desenvolveram NIC: 4 (9,8%) pacientes no grupo bicarbonato e 4 (8,9%) no grupo SF 0,9% (p = 0,9). A variação da creatinina sérica e da DCE foi similar entre os grupos. Conclusão: Hidratação com bicarbonato de sódio não demonstrou benefício em reduzir a incidência de NIC em pacientes diabéticos submetidos a cateterismo cardíaco ou angioplastia coronária em comparação à hidratação com SF 0,9%. / Background: Contrast-induced nephropathy (CIN) is associated with worse clinical outcomes both at short and long-term follow-up. Recent evidence indicates that intravenous hydration with sodium-bicarbonate may reduce the incidence of CIN. However, this strategy has not been reported in diabetic patients. Methods: Sub-analysis of a multicenter study involving 301 patients with serum creatinine ≥ 1,2 mg/dL or creatinine clearance < 50 mL/min submitted to coronary angiography or percutaneous coronary intervention and randomized to intravenous hydration with sodium-bicarbonate or normal saline. All patients received low-osmolar contrast media. We assessed the incidence of CIN (defined as creatinine increase ≥ 0,5 mg/dL), and the average change in creatinine and creatinine clearance 48 hours after the procedure. A total of 87 diabetic patients were analyzed. Results: There was no difference between groups regarding baseline characteristics, contrast volume used, baseline creatinine levels and creatinine clearance. Eight patients presented CIN: 4 (9.8%) in the bicarbonate group and 4 (8.9%) in the saline group (p = 0.9). The average change in serum creatinine and creatinine clearance were similar between groups. Conclusion: Intravenous hydration with sodium-bicarbonate did not reduce the incidence of CIN in diabetic patients undergoing coronary angiography or percutaneous coronary intervention as compared to hydration with normal saline.
|
23 |
Obtenção de micropartículas lipídicas contendo bicarbonato de sódio por spray cooling e de bicarbonato de sódio aglomerado por melt agglomeration em leito vibrofluidizado / The obtaining of lipid microparticles containing sodium bicarbonate by spray cooling and the obtaining of sodium bicarbonate agglomerated by melt agglomeration in vibrofluidized bedPilarski, Emmanuelle, 1979- 19 August 2018 (has links)
Orientadores: Fernanda Paula Collares Queiroz, Sandra Cristina dos Santos Rocha / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-19T14:22:43Z (GMT). No. of bitstreams: 1
Pilarski_Emmanuelle_D.pdf: 13352787 bytes, checksum: 0ecea335c03bb27966c47554b420caee (MD5)
Previous issue date: 2012 / Resumo: O presente trabalho teve como objetivo o desenvolvimento de (i) micropartículas lipídicas contendo bicarbonato de sódio pelo processo de spray cooling e de (ii) aglomerados de bicarbonato de sódio, utilizando-se do processo de melt agglomeration em leito vibrofluidizado. Essas tecnologias foram aplicadas com o intuito de melhorar a estabilidade desse material, uma vez que o mesmo se decompõe na presença de umidade/ou temperaturas mais elevadas. Uma mistura lipídica composta por gordura de palma totalmente hidrogenada (GPTH) e óleo de palma refinado (OP) foi empregada como material de parede/ligante que atendeu ao requisito de ponto de fusão de 55 ºC, com a proporção de 57,5 e 42,5 %, respectivamente. No processo de spray cooling, foi realizado um Delineamento Composto Central Rotacional (DCCR), com 11 ensaios, para cada um dos três diâmetros de abertura de bico atomizador estudados (??igual a 1,0; 1,2 e 1,5 mm), totalizando 33 experimentos, a fim de se avaliar o efeito da temperatura de entrada da dispersão (Te) (65 a 85 ºC) e da pressão de atomização (Pat) (1,0 a 2,0 kgf/cm2) sobre as seguintes variáveis dependentes: (i) eficiência de microencapsulação (EM, % de CO2), (ii), quantidade de bicarbonato de sódio superficial (BSS, % de CO2) e (iii) rendimento (R, em %). As micropartículas apresentaram formato esférico e estrutura de superfície irregular para os ensaios realizados. A análise estatística dos resultados mostrou que para ??= 1,0 mm, um aumento nos níveis da Te e da Pat ocasionou um decréscimo da EM; para o ??= 1,2 mm, o aumento da Te ocasionou uma melhoria nessa resposta, entretanto, a Pat quando aumentada acarretou na sua diminuição. Para o ??= 1,5 mm, essas duas variáveis apresentaram menores efeitos, onde o aumento da Pat favoreceu a EM e o aumento da Te, a sua diminuição. A Te exerceu efeito positivo no R para o ??= 1,0 mm, sem influência nessa resposta para os diâmetros 1,2 e 1,5 mm, enquanto que a Pat teve efeito positivo para ??igual a 1,0 e 1,5 mm (termo linear) e negativo para o termo quadrático deste último. Pela combinação das respostas obtidas, verificou-se que o ensaio 4, diâmetro de bico atomizador (??= 1,5 mm), altas temperatura de entrada e de pressão de atomização (Te = 82 ºC e Pat = 1,85 kgf/cm2) apresentou o melhor desempenho (eficiência 3,18 %; quantidade de bicarbonato de sódio superficial 0,17 % e rendimento 80,0 %) quando comparado com os outros diâmetros de abertura. No processamento em leito vibrofluidizado, foi realizado um DCCR, totalizando 17 ensaios, com o objetivo de avaliar o efeito das variáveis: (i) pressão de atomização (5,0 a 15,0 Psig), (ii) frequência de vibração (186 a 354 rpm) e (iii) amplitude de vibração (0,40 a 2,00 cm), sobre as variáveis dependentes (i): rendimento R (%), (ii) eficiência da aglomeração Eagl (% CO2), para as frações granulométricas de 300, 600 e 840 µm, (iii) crescimento de partícula C3,3 (%) e (iv) índice de torrões Itor (%). O material aglomerado apresentou ampla distribuição de tamanho e a nucleação dos aglomerados ocorreu pelo mecanismo de imersão. Os aglomerados apresentaram Eagl diferentes para as frações avaliadas, sendo que a maior eficiência foi observada para a fração 840 µm, seguida das frações 600 e 300 µm. Contudo, através da comparação entre a Eagl e o C3,3, observou-se que a proteção não depende somente do tamanho da partícula, mas mais importante que isso é o mecanismo de formação do aglomerado, demonstrando a complexidade do processo. Com relação à proteção do material (avaliada pela Eagl), o efeito da pressão, da frequência e da amplitude foi positivo para as frações de 300 µm e 600 e 840 µm (termos quadráticos). Pela combinação das respostas, o ensaio que apresentou melhor desempenho no leito vibrofluidizado foi a de fração 840 µm, cujos parâmetros estavam fixados em baixos valores de pressão e frequência e alta amplitude. Os resultados demonstraram que ocorreu a proteção do bicarbonato de sódio contra a liberação de CO2 para ambos os processos estudados. As técnicas demonstraram grande potencial na produção desses materiais (bicarbonato de sódio microencapsulado e bicarbonato de sódio aglomerado), que se mostram viáveis para serem utilizados na formulação de um novo fermento químico, constituído pelo bicarbonato de sódio microencapsulado ou aglomerado e pelo componente ácido, sem a necessidade do agente inerte (amido) como separador físico / Abstract: This work had the objective of developing: (i) lipid microparticles containing sodium bicarbonate obtained by spray cooling process, and (ii) sodium bicarbonate agglomeration, obtained by melt agglomeration process in a vibrofluidized bed. These technologies were applied with the objective of improving the material stability, since it decomposes in the presence of humidity and/or higher temperatures. A lipid mixture composed of 57.5 % fully hydrogenated palm fat and 42.5 % refined palm oil, whose melting point is 55 ºC, was used. In the spray cooling process, a Central Composite Rotatable Design (CCRD) was applied, with 11 trials for each of the three nozzle atomizer diameters (?) studied (??= 1.0, 1.2 and 1.5 mm). Thirty three experiments were conducted with the objective of evaluating inlet temperature on the dispersion (65 to 85 ºC) and pressure atomization (1.0 to 2.0 kgf/cm2) on the following dependent variables: (i) microencapsulation efficiency (% CO2), (ii) amount of sodium bicarbonate on the surface (% CO2) and (iii) yield (%). The microparticles presented spherical shape and irregular surface. Statistical analysis showed that for ??= 1.0 mm and increases in levels of temperature on the dispersion and pressure atomization, the microencapsulation efficiency dropped. For ??= 1.2 mm, an increase in temperature on the dispersion led to an improvement in this response, however, when pressure atomization was increased, the microencapsulation efficiency fell. For ??= 1.5 mm, these two variables presented smaller effects, on the other hand, an increase in pressure atomization favored the microencapsulation efficiency. Increasing temperature on the dispersion, reduced the microencapsulation efficiency. Temperature on the dispersion presented a positive effect on yield for ??= 1.0 mm (this had no effect on the response for 1.2 and 1.5 mm diameters), while pressure atomization had a positive effect for d = 1.0 and 1.5 mm (linear term), its quadratic term had a negative effect on yield. By combining of dependent variables, it was found for ??= 1.5 mm, test 4, higher temperature on the dispersion and pressure atomization, presented the best performance (3.18 % higher efficiency, 0.17 % lower amount of surface sodium bicarbonate pressure and 80.0 % yield) when compared with the other diameters. In the vibrofluidized bed process, a CCRD was conducted, totaling 17 trials, to assess the effect of these independent variables: (i) atomization pressure (5.0 to 15.0 Psig), (ii) vibration frequency (186 to 354 rpm) and (iii) vibration amplitude (0.40 to 2.00 cm) on the dependent variables: (i) yield (%), (ii) agglomeration efficiency (% CO2), for the particle size fractions of 300, 600 and 840 µm (iii) particle growth (%) and (iv) lump. The agglomerated material presented ample size distribution and the nucleation mechanism occurred by immersion. The agglomeration efficiency presented different values for each fractions tested (300 µm <600 µm <840 µm). However, a comparison of agglomeration efficiency and particle growth, demonstrated that protection depends not only on particle size, but more on the formation mechanism of agglomeration particles, demonstrating its complexity. With regard to the protection of the material (assessed by agglomeration efficiency), the effect of pressure was positive for 300, 600 µm, and 840 µm fractions (quadratic terms), while the frequency had a positive effect for the three fractions. With respect to amplitude, the effect was positive on the larger particle size fractions. Considering all answers, the test that produced the best performance in the vibrofluidized bed was 840 µm fraction, whose parameters were set at low pressure and frequency values and high amplitude. The results showed that there was protection of sodium bicarbonate against the release of CO2 for both processes studied. The techniques demonstrated great potential in the production of these materials (microencapsulated sodium bicarbonate and agglomerated sodium bicarbonate particles), thus demonstrating its viability for use in the formulation of a new baking powder. A new baking soda, consisting of microencapsuled sodium bicarbonate or agglomerated and another acid compound, without the need for an inert agent (starch) as physical separator / Doutorado / Tecnologia de Alimentos / Doutor em Tecnologia de Alimentos
|
24 |
Ingestão de bicarbonato de sódio e cloreto de amônio e seus efeitos sobre o ritmo de prova, desempenho e equilíbrio ácido-base em um teste contrarrelógio de ciclismo de 4km / Sodium bicarbonate and ammonium chloride ingestion and their effects on pacing, performance and acid-base balance during a 4-km cycling time trialOliveira, Carlos Rafaell Correia de 09 June 2016 (has links)
Nós determinamos a influência da alcalose e acidose metabólica induzida sobre o ritmo de prova, gasto energético e desempenho durante um teste contrarrelógio de ciclismo de 4 km (TCR). Após um estudo preliminar (N=7) determinando as doses ótimas de cloreto de amônio (NH4Cl), bicarbonato de sódio (NaHCO3) e placebo (carbonato de cálcio, CaCO3), 11 ciclistas amadores realizaram um TCR de 4 km 100 min após ingerirem 0,15 g·kg-1 de NH4Cl, 0,3 g·kg-1 de NaHCO3 ou 0,15 g·kg-1 de CaCO3 (desenho de medidas repetidas, contrabalançado e duplo-cego). Comparado com placebo, a ingestão de NaHCO3 resultou em uma alcalose sanguínea pré-exercício (pH: + 0,06 ± 0,04, [HCO3-]: + 4,7 ± 2,6 mmol?L-1, excess de base: + 4,6 ± 2,4 mmol?L-1, P<0,05), enquanto que o NH4Cl resultou em uma acidose sanguínea (pH: - 0,05 ± 0,04, [HCO3-]: - 5,5 ± 2,9 mmol?L-1, excesso de base: - 5,3 ± 2,5 mmol?L-1, P<0.05), com essas diferenças permanecendo durante todo o teste. Apesar de nenhum desconforto gastrointestinal severo, os participantes adotaram um ritmo de prova significativamente mais conservador em NH4Cl comparado com placebo e NaHCO3, que foi acompanhado por uma redução na taxa de gasto energético anaeróbio (~ -14 %, P<0,05) e menor trabalho anaeróbio total (~ -13 %, P<0,05). Consequentemente, o desempenho foi prejudicado em NH4Cl (~ -7 %) comparado com as demais condições (P<0,05). O lactato plasmático, VCO2 e a PetCO2 foram menores e a VE/VCO2 maior durante o TCR em acidose do que em placebo e alcalose (P<0,05). Entretanto, não houve diferença para essas variáveis entre placebo e NaHCO3 (P<0,05). A acidose metabólica induzida diminuiu o ritmo de prova e o metabolismo anaeróbio, além de prejudicar o desempenho durante um TCR de 4 km, independente de desconforto gastrointestinal / We determined the influence of induced metabolic alkalosis and metabolic acidosis on pacing, energy expenditure and performance during a 4-km cycling time trial (TT). After a preliminary study (N=7) determining the optimal ammonium chloride (NH4Cl), sodium bicarbonate (NaHCO3), and placebo (calcium carbonate, CaCO3) doses, 11 amateur cyclists performed a 4-km TT 100 min after ingesting either 0.15 g·kg-1 of body mass of NH4Cl, 0.3 g·kg-1 of NaHCO3 or 0.15 g·kg-1 of CaCO3 (double-blind, counterbalanced and repeated-measures design). Compared with placebo, the NaHCO3 ingestion resulted in a pre exercise blood alkalosis (pH: +0.06 ± 0.04, [HCO3-]: +4.7 ± 2.6 mmol?L-1, base excess: +4.6 ± 2.4 mmol?L-1, P<0.05), while NH4Cl resulted in a blood acidosis (pH: -0.05 ± 0.04, [HCO3-]: -5.5 ± 2.9 mmol?L-1, base excess: -5.3 ± 2.5 mmol?L-1, P<0.05), with these differences remaining throughout the trial. Despite no gastrointestinal distress, participants adopted a significant more conservative pacing in NH4Cl compared with placebo and NaHCO3, which was accompanied by a reduced anaerobic energy expenditure rate (~ -14 %, P<0.05) and lower total anaerobic work (~ -13 %, P<0.05). Consequently, the performance was less in NH4Cl (~ -7 %) compared with other conditions (P<0.05). Plasma lactate, VCO2 and PetCO2 were lower and the VE/VCO2 higher during the TT in acidosis than in placebo and alkalosis (P<0.05). However, there was no difference for these variables between placebo and NaHCO3 (P>0.05). Induced metabolic acidosis slows pacing, decreases anaerobic metabolism and impairs performance during a 4-km TT, independent of gastrointestinal distress
|
25 |
Efeito in situ de uma solução de bicarbonato de sódio em esmalte dental após simulação de desafios erosivos endógenos / In situ effect of a sodium bicarbonate solution on enamel after simulation of endogenous dental erosion.Messias, Danielle Cristine Furtado 10 February 2010 (has links)
Uma das medidas recomendadas para o controle da progressão de lesões de erosão dental de origem intrínseca é o enxágüe bucal com solução de bicarbonato de sódio, visando à neutralização de ácidos gástricos presentes na boca. Contudo, a prescrição de tal solução faz-se em bases empíricas. Assim, este estudo avaliou, através de um modelo in situ, o efeito de uma solução de bicarbonato de sódio no controle da erosão dental causada por desafios ácidos endógenos. Este estudo caracterizou-se por um experimento do tipo cross-over 2x2, composto por duas fases experimentais de 5 dias cada. Após um período de lead-in de 2 dias, quatorze voluntários utilizaram dispositivos intrabucais contendo, em cada lado (direito e esquerdo), um fragmento de esmalte bovino polido, esterilizado e delimitado de modo a obter áreas hígidas de referência. Duas vezes ao dia, um dos espécimes foi exposto, ex-vivo, à solução de ácido clorídrico (0,01 M, pH = 2) por 2 min. Imediatamente após, os aparelhos foram reinseridos na boca e os voluntários realizaram enxágüe bucal com solução de bicarbonato de sódio ou água deionizada por 1 min. Após um período de wash-out de 2 dias, os voluntários iniciaram a segunda fase empregando a substância alternativa para o enxágüe bucal. Ao término das duas etapas, foram avaliadas a profundidade de desgaste através de perfilometria ótica e a microdureza Knoop. ANOVA e o teste de Tukey demonstraram que o desgaste do esmalte foi significativamente reduzido quando se empregou a solução de bicarbonato de sódio para o enxágüe bucal. Para a microdureza, ANOVA demonstrou apenas presença de diferença significativa em função da condição do substrato (p < 0,0001). Os espécimes erodidos apresentaram valores de microdureza significativamente menores do que o grupo não submetido ao desafio ácido. O enxágüe bucal com solução de bicarbonato de sódio controlou a erosão no esmalte submetido a simulações de episódios erosivos endógenos. / One of the recommended measures to control dental erosion of intrinsic origin is the oral rinse with sodium bicarbonate solution, which has been suggested to neutralize the gastric acid regurgitated into the oral cavity. However, the efficacy of this prescription has not yet been proved. Therefore, the aim of this study was to evaluate in situ the effect of a sodium bicarbonate rinse in the control of dental erosion in enamel exposed to gastric acid-like solution. This study comprised two experimental legs. After a 2-day lead-in period, fourteen volunteers wore palatal devices containing two polished, sterilized enamel slabs. Throughout the experimental period of 5-d, one of the two specimens was exposed twice daily extra-orally to hydrochloric acid solution (0,01 M, pH=2) for 2 min. Immediately after, devices were reinserted in the mouth and volunteers rinsed their oral cavity with a sodium bicarbonate solution or deionized water for 60s. In the second leg of this study, after a 2-day washout period, appliances were refilled with a new set of enamel specimens and participants were crossed over to receive the alternate rinse. The wear depth accessed using optical profilometry and Knoop surface microhardness were evaluated. Analysis of Variance (ANOVA) and Tukey\'s test demonstrated that wear of enamel was significantly reduced when a sodium bicarbonate solution was used to rinse the oral cavity following erosive episodes. For microhardness, ANOVA demonstrated only significant differences in function of the enamel condition (p < 0,0001). The eroded specimens presented microhardness values significantly lower than the group not submitted to the acid challenge. Sodium bicarbonate rinse controlled erosion of enamel caused by gastric acid-like solution.
|
26 |
Efeito de antioxidantes na resistência adesiva à microtração do esmalte bovino clareado após 7 dias e 6 meses de armazenamento / Effect of antioxidants on bleached enamel microtensile bond strength after 7 days and 6 months storageFalcão, Marina Studart Alencar 28 February 2013 (has links)
Este estudo in vitro avaliou o efeito do bicarbonato de sódio 10% (BS) e do hidrogel de ascorbato de sódio 10% (AS) na resistência adesiva à microtração de uma resina composta unida à superfície de esmalte bovino clareado com peróxido de hidrogênio 35% (PH). Cento e vinte superfícies de esmalte vestibular com dimensões de 4mmX4mm de incisivos bovinos foram planificadas e separadas em cinco grupos: C - não clareado e restaurado; OI - clareado com PH e restaurado imediatamente; O7 - clareado com PH, armazenado por 7 dias em água destilada e restaurado; OBS - clareado com PH, BS 10% durante 5 min e restaurado; OAS - clareado com PH, AS 10% durante 15 min e restaurado. O gel de PH (Total Blanc Office, Nova DFL) foi aplicado duas vezes de 20 minutos em cada espécime e as restaurações foram confeccionadas com sistema adesivo restaurador (Natural Bond DE + Natural Look, Nova DFL). Após uma semana, os espécimes foram seccionados para obtenção de palitos com 1,00 mm2 de área média e submetidos ao teste de microtração em máquina de teste universal a 0,5mm/min, imediatamente e após 6 meses. As falhas foram avaliadas em estereomicroscópio digital (200x) e classificadas em: adesiva, coesiva em esmalte, coesiva em resina e mista. Os dados foram analisados por ANOVA a dois critérios e teste de Tukey para comparações múltiplas (p<0,05). Os valores médios de resistência adesiva (MPa ± DP; imediatamente / 6 meses) foram: C (24,22 ± 7,74 Ba / 20,13 ± 6,43 BCa); OI (18,29 ± 5,88 Ca / 25,85 ± 5,23 Ab); O7 (40,88 ± 7,95 Aa / 24,61 ± 7,83 ABb); OBS (19,95 ± 5,67 BCa / 15,94 ± 5,57 CDa); OAS (24,43 ± 6,43 Ba / 13,69 ± 5,58 Db). Das estratégias antioxidantes avaliadas após 7 dias, os grupos OAS e OBS não diferiram estatisticamente do grupo C, nem OBS diferiu estatisticamente do grupo OI. Nesse período de avaliação, somente o grupo O7 apresentou diferença significativa em relação aos demais grupos. Após 6 meses de envelhecimento, apenas O7 e OBS apresentaram desempenho semelhante estatisticamente ao grupo C. O percentual de falhas (7 dias / 6 meses) foi: adesiva (65,26% / 67,06%); coesiva em esmalte (14,74% / 24,71%); coesiva em resina (1,58% / 2,35%); mista (18,42% / 5,88%). Em função dos resultados apresentados, a estratégia mais segura é aguardar 7 dias após o clareamento para a realização de restaurações adesivas. Quando não for possível aguardar este tempo, a aplicação de bicarbonato de sódio 10% por 5 minutos sobre o esmalte clareado deve ser feita. / This \"in vitro\" study evaluated the effect of 10% sodium bicarbonate (SB) and 10% sodium ascorbate (SA) hydrogel on the composite resin microtensile bond strength of bleached bovine enamel with 35% hydrogen peroxide (HP). One hundred and twenty buccal enamel surfaces with dimensions of 4mmX4mm of bovine incisors were flattened and separated into five groups: C - not bleached and restored, OI - bleached with HP and immediately restored; O7 - bleached with HP, stored for 7 days in distilled water and restored; OBS - bleached with HP, 10% SB for 5 min and restored; OAS - bleached with HP, 10% SA for 15 min and restored. HP gel (Total Blanc Office, Nova DFL) was applied twice for 20 minutes on each specimen and the restorations were performed with an adhesive restorative system (Natural Bond DE + Natural Look, Nova DFL). After a week, the specimens were sectioned into sticks with a 1.00 mm2 average area and submitted to a microtensile test in a universal testing machine at 0.5 mm/min, immediately and after 6 months. The failures were evaluated in a digital stereoscope (200x) and classified as: adhesive, cohesive in enamel, cohesive in resin and mixed. Data was analyzed by two-way ANOVA and Tukey\'s test for multiple comparisons (p <0.05). The average values of the bond strength (MPa ± SD; immediately / 6 months) were: C (24.22 ± 7.74 Ba / 20.13 ± 6.43 BCa) OI (18.29 ± 5.88 Ca / 25.85 ± 5.23 Ab); O7 (40.88 ± 7.95 Aa / 24.61 ± 7.83 ABb), OBS (19.95 ± 5.67 BCa / 15.94 ± 5.57 CDa), OAS (24.43 ± 6.43 Ba / 13.69 ± 5.58 Db). Among the antioxidant strategies evaluated after 7 days, the OAS and OBS groups did not differ from group C and neither OBS group differed from the OI group. In the same evaluation period, only the O7 group presented a significant difference compared to the other groups. After 6 months of aging, only the O7 and OBS groups performed statistically similar to group C. The percentage of failures (7 days / 6 months) was: adhesive (65.26% / 67.06%); cohesive in enamel (14.74% / 24.71%); cohesive in resin (1.58% / 2.35%); mixed (18.42% / 5.88%). According to the results presented, the safety strategy is waiting 7 days after bleaching for the adhesive restorative procedures. When this waiting period is not possible, 10% sodium bicarbonate should be applied for 5 minutes on the bleached enamel.
|
27 |
Ingestão de bicarbonato de sódio e cloreto de amônio e seus efeitos sobre o ritmo de prova, desempenho e equilíbrio ácido-base em um teste contrarrelógio de ciclismo de 4km / Sodium bicarbonate and ammonium chloride ingestion and their effects on pacing, performance and acid-base balance during a 4-km cycling time trialCarlos Rafaell Correia de Oliveira 09 June 2016 (has links)
Nós determinamos a influência da alcalose e acidose metabólica induzida sobre o ritmo de prova, gasto energético e desempenho durante um teste contrarrelógio de ciclismo de 4 km (TCR). Após um estudo preliminar (N=7) determinando as doses ótimas de cloreto de amônio (NH4Cl), bicarbonato de sódio (NaHCO3) e placebo (carbonato de cálcio, CaCO3), 11 ciclistas amadores realizaram um TCR de 4 km 100 min após ingerirem 0,15 g·kg-1 de NH4Cl, 0,3 g·kg-1 de NaHCO3 ou 0,15 g·kg-1 de CaCO3 (desenho de medidas repetidas, contrabalançado e duplo-cego). Comparado com placebo, a ingestão de NaHCO3 resultou em uma alcalose sanguínea pré-exercício (pH: + 0,06 ± 0,04, [HCO3-]: + 4,7 ± 2,6 mmol?L-1, excess de base: + 4,6 ± 2,4 mmol?L-1, P<0,05), enquanto que o NH4Cl resultou em uma acidose sanguínea (pH: - 0,05 ± 0,04, [HCO3-]: - 5,5 ± 2,9 mmol?L-1, excesso de base: - 5,3 ± 2,5 mmol?L-1, P<0.05), com essas diferenças permanecendo durante todo o teste. Apesar de nenhum desconforto gastrointestinal severo, os participantes adotaram um ritmo de prova significativamente mais conservador em NH4Cl comparado com placebo e NaHCO3, que foi acompanhado por uma redução na taxa de gasto energético anaeróbio (~ -14 %, P<0,05) e menor trabalho anaeróbio total (~ -13 %, P<0,05). Consequentemente, o desempenho foi prejudicado em NH4Cl (~ -7 %) comparado com as demais condições (P<0,05). O lactato plasmático, VCO2 e a PetCO2 foram menores e a VE/VCO2 maior durante o TCR em acidose do que em placebo e alcalose (P<0,05). Entretanto, não houve diferença para essas variáveis entre placebo e NaHCO3 (P<0,05). A acidose metabólica induzida diminuiu o ritmo de prova e o metabolismo anaeróbio, além de prejudicar o desempenho durante um TCR de 4 km, independente de desconforto gastrointestinal / We determined the influence of induced metabolic alkalosis and metabolic acidosis on pacing, energy expenditure and performance during a 4-km cycling time trial (TT). After a preliminary study (N=7) determining the optimal ammonium chloride (NH4Cl), sodium bicarbonate (NaHCO3), and placebo (calcium carbonate, CaCO3) doses, 11 amateur cyclists performed a 4-km TT 100 min after ingesting either 0.15 g·kg-1 of body mass of NH4Cl, 0.3 g·kg-1 of NaHCO3 or 0.15 g·kg-1 of CaCO3 (double-blind, counterbalanced and repeated-measures design). Compared with placebo, the NaHCO3 ingestion resulted in a pre exercise blood alkalosis (pH: +0.06 ± 0.04, [HCO3-]: +4.7 ± 2.6 mmol?L-1, base excess: +4.6 ± 2.4 mmol?L-1, P<0.05), while NH4Cl resulted in a blood acidosis (pH: -0.05 ± 0.04, [HCO3-]: -5.5 ± 2.9 mmol?L-1, base excess: -5.3 ± 2.5 mmol?L-1, P<0.05), with these differences remaining throughout the trial. Despite no gastrointestinal distress, participants adopted a significant more conservative pacing in NH4Cl compared with placebo and NaHCO3, which was accompanied by a reduced anaerobic energy expenditure rate (~ -14 %, P<0.05) and lower total anaerobic work (~ -13 %, P<0.05). Consequently, the performance was less in NH4Cl (~ -7 %) compared with other conditions (P<0.05). Plasma lactate, VCO2 and PetCO2 were lower and the VE/VCO2 higher during the TT in acidosis than in placebo and alkalosis (P<0.05). However, there was no difference for these variables between placebo and NaHCO3 (P>0.05). Induced metabolic acidosis slows pacing, decreases anaerobic metabolism and impairs performance during a 4-km TT, independent of gastrointestinal distress
|
28 |
ESTRATÉGIAS PARA A REMOÇÃO DE PIGMENTOS DEPOSITADOS SOBRE BRÁQUETES ESTÉTICOS / STRATEGIES FOR REMOVAL OF PIGMENTS DEPOSITED ON AESTHETIC BRACKETSOtero, Laura Meireles 25 July 2016 (has links)
The aim of this study was to evaluate the efficiency of cleaning methods in removing pigment deposited on aesthetic brackets, after immersion in coffee. We selected 160 premolar brackets (80 monocrystalline and polycrystalline 80). The brackets were fixed on a glass blade and soon, thereafter, color measurement was performed using a spectrophotometer (T0). For each means of immersion, 80 brackets were selected (40 for each type of ceramic). Soon after staining (30 days of immersion), new color measurements were made (T1). Subsequently, the specimens were divided randomly into four groups for brushing, bleaching, blasting with sodium bicarbonate jet and sodium bicarbonate jet followed by bleaching. New color measurements were made after each cleaning method was used (T2). The color change of the brackets was evaluated according to two formulae, i.e., CIELAB and CIEDE2000. The differences between the average ΔE according to treatment, bracket, and solution were evaluated by linear regression analysis. The greatest staining was caused by coffee. The crystalline structure did not influence the color change. The methods with lower averages of ΔE for coffee were sodium bicarbonate jet followed by bleaching and bleaching, followed by the group that received brushing and sodium bicarbonate jet (both CIELAB as to CIEDE2000). The CIEDE2000 formula was more sensitive in detecting non-acceptable and perceptible differences in color when compared with the CIELAB formula. It was concluded that the most effective methods to remove pigment deposited on aesthetic brackets are sodium bicarbonate jet followed by bleaching and bleaching alone. / O objetivo desse estudo foi avaliar a eficiência dos métodos de limpeza na remoção de pigmentos depositados sobre bráquetes estéticos, após imersão em café. Foram selecionados 160 bráquetes (80 monocristalinos e 80 policristalinos) de pré-molares superiores. Os bráquetes foram fixados em uma lâmina de vidro e logo depois a mensuração de cor foi realizada com um espectrofotômetro (T0). Cada meio de imersão (café ou saliva) continha 80 bráquetes (40 para cada tipo de cerâmica). Logo após a coloração (30 dias de imersão) novas aferições foram feitas (T1). Posteriormente, os espécimes foram divididos randomicamente em 4 grupos: Grupo 1 Escovação; Grupo 2 Clareamento; Grupo 3 Jateamento com bicarbonato de sódio; Grupo 4 Jateamento com bicarbonato de sódio seguido de Clareamento. Novas aferições foram feitas depois de cada método de limpeza (T2). A variação da cor dos bráquetes foi avaliada de acordo com 2 fórmulas: CIELAB E CIEDE2000. As diferenças entre as médias de ΔE de acordo com o tratamento, braquete e solução foram avaliadas através de análise de regressão linear. O café promoveu maior manchamento. A estrutura cristalina não influenciou na alteração de cor. Os métodos com menores médias de ΔE, no café, foram o jateamento com posterior clareamento e o clareamento sozinho, seguido dos grupos que receberam jateamento e escovação (tanto para CIELAB quanto para CIEDE2000). A fórmula CIEDE2000 foi mais sensível em detectar diferenças de cor não-aceitáveis e perceptíveis quando comparado à fórmula CIELAB. Conclui-se que os métodos mais eficazes na remoção de pigmentos depositados sobre bráquetes estéticos são o jateamento com bicarbonato de sódio com posterior clareamento e o clareamento sozinho.
|
29 |
Suplementação com bicarbonato de sódio: influência sobre o desempenho, respostas fisiológicas e neuromusculares durante e após exercício supramáximo no ciclismo / Sodium bicarbonate supplementation: effect on physiological and neuromuscular performance during and after supramaximal exercises in cyclingSchlickmann, Jardel 23 April 2012 (has links)
Made available in DSpace on 2016-12-06T17:06:50Z (GMT). No. of bitstreams: 1
Jardel Schlickmann.pdf: 828069 bytes, checksum: 28142f1471dd5fe8cbc06d71583812dd (MD5)
Previous issue date: 2012-04-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this study was to determine whether supplementation with sodium bicarbonate (NaHCO3) changes in performance during supramaximal cycling exercise (ESupra), the cardiorespiratory variables and subsequent isometric muscle strength (IMS). The study include 8 male subjects, physically active (23,0±4,01years; 54,69±6,51ml/kg/min-1). The subjects underwent an all out ESupra at 1min in cycle ergometer with load 0,075 kg/weight, after ingestion of solution 0,3g/kg with NaHCO3 or placebo (PLAC) with 0,045g/kg NaCl. After performed the IMS for the upper and lower limbs. The NaHCO3 did not affect the ESupra (497,45±52,47W) compared with PLAC (497,97±60,15W). There were no effects of the ESupra or NaHCO3 ingestion of the test IMS for the elbow flexors (NaHCO3 pre 38,4±6,6kgf and post 36,7±7,8kgf; PLAC pre 37,1±6,8kgf and post 36,2±8,0kgf), as well as for IMS the knee extensors (NaHCO3 pre 84,68±12,36kgf and after 80,28±11,88kgf; PLAC pre 87,04±16,38kgf and after 81,20±13,41kgf). In relation the physiological responses was observed a significant increase at the end of the ESupra only to VCO2 (4,93±0,47l/min) in the condition NaHCO3 compared to PLAC (4,44±0,28l/min). No differences were observed for VO2, VE and VCO2 at anytime during recovery. Lactate concentrations were differently to blood condition NaHCO3 compared to PLAC from the second minute after the ESupra. Before these results, it is likely that the increase in blood lactate concentration after ingestions of NaHCO3 was due to increased release of lactate exercised by muscle and/or by decreasing the absorption in other tissues, since not presented evidence of increased production during exercise (i.e. improved performance). Moreover, the largest peak value during the VCO2 in ESupra suggest a lager buffering H+ generated by supplementation with NaHCO3. Despite evidence to demonstrate the action of NaHCO3 on acid-base balance and transport of lactate the administration of the alkaloid did not favor the performance of 1min ESupra or the IMS of the upper and lower limbs in active individuals. / O objetivo deste estudo foi verificar se a suplementação com bicarbonato de sódio (NaHCO3) altera o desempenho durante exercícios supramáximos no ciclismo (ESupra), as variáveis cardiorrespiratórias, e a força muscular isométrica subseqüente. Participaram deste estudo 8 sujeitos do sexo masculino, fisicamente ativos (23,0±4,01anos; 54,69±6,51ml/kg/min-1). Os voluntários foram submetidos a um ESupra de 1min no cicloergômetro, com carga 0,075 kg/peso, após a ingestão de uma solução com 0,3g/kg NaHCO3 ou placebo (PLAC) com 0,045g/kg de NaCl. Em seguida realizaram os testes de força máxima isométrica (FMI) para os membros superiores e inferiores. O NaHCO3 não teve efeito sobre o desempenho no ESupra (497,45±52,47W) comparado ao PLAC (497,97±60,15W). Não foram observados efeitos do ESupra nem da ingestão do NaHCO3 no teste para FMI dos flexores do cotovelo (NaHCO3 pré 38,4±6,6kgf e pós 36,7±7,8kgf; PLAC pré 37,1±6,8kgf e pós 36,2±8,0kgf), como também para a FMI dos extensores do joelho (NaHCO3 pré 84,68±12,36kgf e pós 80,28±11,88kgf; PLAC pré 87,04±16,38kgf e pós 81,20±13,41kgf). Em relação às respostas fisiológicas foi observado um aumento significativo durante o ESupra apenas para o pico de VCO2 (4,93±0,47l/min) na condição NaHCO3 comparado com o PLAC (4,44±0,28l/min), sem diferenças significativas para essa variável durante a recuperação. Não foram observadas diferenças significativas para o VO2 e VE em qualquer momento durante a recuperação. As concentrações de lactato sanguíneo foram diferentes para condição NaHCO3 quando comparado com o PLAC à partir do segundo minuto após o ESupra até o final dos 30min de recuperação. Diante dos resultados encontrados, é provável que o aumento na concentração do lactato sanguíneo após ingestão de NaHCO3 seja decorrente da maior liberação do íon pela musculatura exercitada e/ou pela diminuição da absorção nos outros tecidos, uma vez que não foram apresentados indícios de uma maior produção durante o exercício (i.e. melhora na performance). Além disso, o maior valor de VCO2 pico durante o ESupra sugere um maior tamponamento do H+ gerado pela suplementação com NaHCO3. Apesar de demonstrarmos indícios da ação do bicarbonato sobre o equilíbrio acidobásico e no transporte de lactato, a administração do alcalóide não favoreceu o ESupra de 1min no ciclismo nem a força máxima isométrica de membros superiores e inferiores em indivíduos ativos.
|
30 |
Efeito de antioxidantes na resistência adesiva à microtração do esmalte bovino clareado após 7 dias e 6 meses de armazenamento / Effect of antioxidants on bleached enamel microtensile bond strength after 7 days and 6 months storageMarina Studart Alencar Falcão 28 February 2013 (has links)
Este estudo in vitro avaliou o efeito do bicarbonato de sódio 10% (BS) e do hidrogel de ascorbato de sódio 10% (AS) na resistência adesiva à microtração de uma resina composta unida à superfície de esmalte bovino clareado com peróxido de hidrogênio 35% (PH). Cento e vinte superfícies de esmalte vestibular com dimensões de 4mmX4mm de incisivos bovinos foram planificadas e separadas em cinco grupos: C - não clareado e restaurado; OI - clareado com PH e restaurado imediatamente; O7 - clareado com PH, armazenado por 7 dias em água destilada e restaurado; OBS - clareado com PH, BS 10% durante 5 min e restaurado; OAS - clareado com PH, AS 10% durante 15 min e restaurado. O gel de PH (Total Blanc Office, Nova DFL) foi aplicado duas vezes de 20 minutos em cada espécime e as restaurações foram confeccionadas com sistema adesivo restaurador (Natural Bond DE + Natural Look, Nova DFL). Após uma semana, os espécimes foram seccionados para obtenção de palitos com 1,00 mm2 de área média e submetidos ao teste de microtração em máquina de teste universal a 0,5mm/min, imediatamente e após 6 meses. As falhas foram avaliadas em estereomicroscópio digital (200x) e classificadas em: adesiva, coesiva em esmalte, coesiva em resina e mista. Os dados foram analisados por ANOVA a dois critérios e teste de Tukey para comparações múltiplas (p<0,05). Os valores médios de resistência adesiva (MPa ± DP; imediatamente / 6 meses) foram: C (24,22 ± 7,74 Ba / 20,13 ± 6,43 BCa); OI (18,29 ± 5,88 Ca / 25,85 ± 5,23 Ab); O7 (40,88 ± 7,95 Aa / 24,61 ± 7,83 ABb); OBS (19,95 ± 5,67 BCa / 15,94 ± 5,57 CDa); OAS (24,43 ± 6,43 Ba / 13,69 ± 5,58 Db). Das estratégias antioxidantes avaliadas após 7 dias, os grupos OAS e OBS não diferiram estatisticamente do grupo C, nem OBS diferiu estatisticamente do grupo OI. Nesse período de avaliação, somente o grupo O7 apresentou diferença significativa em relação aos demais grupos. Após 6 meses de envelhecimento, apenas O7 e OBS apresentaram desempenho semelhante estatisticamente ao grupo C. O percentual de falhas (7 dias / 6 meses) foi: adesiva (65,26% / 67,06%); coesiva em esmalte (14,74% / 24,71%); coesiva em resina (1,58% / 2,35%); mista (18,42% / 5,88%). Em função dos resultados apresentados, a estratégia mais segura é aguardar 7 dias após o clareamento para a realização de restaurações adesivas. Quando não for possível aguardar este tempo, a aplicação de bicarbonato de sódio 10% por 5 minutos sobre o esmalte clareado deve ser feita. / This \"in vitro\" study evaluated the effect of 10% sodium bicarbonate (SB) and 10% sodium ascorbate (SA) hydrogel on the composite resin microtensile bond strength of bleached bovine enamel with 35% hydrogen peroxide (HP). One hundred and twenty buccal enamel surfaces with dimensions of 4mmX4mm of bovine incisors were flattened and separated into five groups: C - not bleached and restored, OI - bleached with HP and immediately restored; O7 - bleached with HP, stored for 7 days in distilled water and restored; OBS - bleached with HP, 10% SB for 5 min and restored; OAS - bleached with HP, 10% SA for 15 min and restored. HP gel (Total Blanc Office, Nova DFL) was applied twice for 20 minutes on each specimen and the restorations were performed with an adhesive restorative system (Natural Bond DE + Natural Look, Nova DFL). After a week, the specimens were sectioned into sticks with a 1.00 mm2 average area and submitted to a microtensile test in a universal testing machine at 0.5 mm/min, immediately and after 6 months. The failures were evaluated in a digital stereoscope (200x) and classified as: adhesive, cohesive in enamel, cohesive in resin and mixed. Data was analyzed by two-way ANOVA and Tukey\'s test for multiple comparisons (p <0.05). The average values of the bond strength (MPa ± SD; immediately / 6 months) were: C (24.22 ± 7.74 Ba / 20.13 ± 6.43 BCa) OI (18.29 ± 5.88 Ca / 25.85 ± 5.23 Ab); O7 (40.88 ± 7.95 Aa / 24.61 ± 7.83 ABb), OBS (19.95 ± 5.67 BCa / 15.94 ± 5.57 CDa), OAS (24.43 ± 6.43 Ba / 13.69 ± 5.58 Db). Among the antioxidant strategies evaluated after 7 days, the OAS and OBS groups did not differ from group C and neither OBS group differed from the OI group. In the same evaluation period, only the O7 group presented a significant difference compared to the other groups. After 6 months of aging, only the O7 and OBS groups performed statistically similar to group C. The percentage of failures (7 days / 6 months) was: adhesive (65.26% / 67.06%); cohesive in enamel (14.74% / 24.71%); cohesive in resin (1.58% / 2.35%); mixed (18.42% / 5.88%). According to the results presented, the safety strategy is waiting 7 days after bleaching for the adhesive restorative procedures. When this waiting period is not possible, 10% sodium bicarbonate should be applied for 5 minutes on the bleached enamel.
|
Page generated in 0.1041 seconds