• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 305
  • 112
  • 60
  • 14
  • 11
  • 10
  • 10
  • 10
  • 10
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • Tagged with
  • 606
  • 241
  • 207
  • 162
  • 123
  • 118
  • 103
  • 85
  • 82
  • 80
  • 72
  • 69
  • 58
  • 55
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Influencia de diferentes formulações de agentes clareadores nas propriedades fisicas e quimicas do esmalte e dentina / Influence of different formulations of bleaching agents on enamel and dentin physical and chemical properties

Cavalli, Vanessa, 1977- 31 January 2007 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T06:09:23Z (GMT). No. of bitstreams: 1 Cavalli_Vanessa_D.pdf: 23996439 bytes, checksum: 05d01cea80d0ce7dd869bda3fee7de31 (MD5) Previous issue date: 2007 / Resumo: Desde a introdução da técnica de clareamento caseiro utilizando-se peróxido de carbamida (PC) a 10% estudos têm verificado os efeitos do agente clareador na superfície do esmalte humano erupcionado. Evidências demonstram que o peróxido de carbamida é capaz de alterar a composição e morfologia desse substrato. Com o intuito de diminuir os efeitos adversos dos agentes clareadores na superfície do esmalte dental, fluoretos e outros íons têm sido incluídos na formulação do agente clareador. No entanto, poucos estudados foram realizados sobre os efeitos desses agentes contendo aditivos na superfície do esmalte hígido ou com lesões artificiais de cárie. Assim, o objetivo desse trabalho foi avaliar as alterações na superfície do esmalte hígido ou com lesões de mancha branca após o tratamento com agentes clareadores à base de peróxido de carbamida 10% com ou sem adição de íons fluoreto (F) ou cálcio (Ca). Blocos de esmalte da superfície vestibular e lingual de terceiros molares humanos foram obtidos e preparados para determinação da microdureza de superfície inicial. Após seleção dos espécimes, metade foi submetida à desmineralização para indução de lesão de cárie subsuperficial (mancha branca) do esmalte. Foi realizada nova análise de microdureza de superfície e a determinação da concentração de fosfato na superfície do esmalte através da Espectroscopia Raman com Transformada de Fourier (ERTF), tanto das amostras hígidas quanto das desmineralizadas. Os corpos de prova hígidos e com lesão de cárie subsuperficial foram divididos aleatoriamente em seisgrupos experimentais (n=10): (PLA) Placebo; (WHI) Whiteness® (10% PC); (OPA) Opalescence F¿ (10% PC+0,11% F); (PN) Pola Night F¿ (10% PC+ 0,11% F) e agentes clareadores experimentais (F) 10% PC + 0,5% F e (Ca) 10% PC + 0,2% Ca. O tratamento clareador foi realizado durante 6 horas diárias e após cada sessão, os espécimes foram mantidos em solução remineralizante até a próxima aplicação do gel. Os tratamentos clareadores tiveram duração de 12 dias. No 1º, 6º e 12º dias de tratamento clareador, foram realizadas determinações da microdureza de superfície de todos os espécimes e obtidas as soluções de enxágüe para determinação da concentração de cálcio, flúor e fósforo inorgânico por meio dos métodos de espectroscopia de absorção atômica, eletrodo específico e análise colorimétrica, respectivamente. Após os 12 dias de tratamento clareador, nova determinação de ERTF foi realizada e os espécimes foram preparados para determinação da microdureza do esmalte seccionado longitudinalmente e microscopia de luz polarizada. Os resultados obtidos indicam que houve diminuição da microdureza do esmalte hígido e com lesão de cárie após o tratamento clareador, sendo que o grupo WHI, sem aditivos, provocou a maior perda mineral da superfície de esmalte hígido e com lesão de cárie subsuperficial. As análises químicas comprovaram a diminuição da concentração de íons da superfície de esmalte devido ao aumento de íons cálcio, flúor e fósforo inorgânico na solução de enxágüe. A microdureza interna e a microscopia de luz polarizada indicaram maior desmineralização para os substratos tratados com o agente WHI. Os agentes contendo altas concentrações de cálcio apresentaram bom desempenho no esmalte hígido, enquanto os agentes contendo altas concentrações de flúor foram importantes para as propriedades químicas do esmalte com lesão de cárie subsuperficial. Parte B: Efeitos de agentes clareadores intracoronários na superfície dentinária. O objetivo desse estudo foi verificar a influência de quatro agentes para clareamento de dentes não-vitais no substrato dentinário hígido ou pré-condicionado. Incisivos bovinos foram preparados para o tratamento clareador intracoronário. Metade dos elementos dentais foram submetidos internamente ao condicionamento prévio com ácido fosfórico 37% durante 15 segundos. Os incisivos hígidos e pré-condicionados foram divididos aleatoriamente em 5 grupos experimentais: (C) Controle ¿ sem tratamento clareador; (PH 35%) Peróxido de hidrogênio 35%; (PH 25%) Peróxido de hidrogênio 25%; (PC 35%) Peróxido de carbamida 35% e (PS) Perborato de Sódio e água destilada. Os clareadores foram aplicados em 4 sessões com intervalo de 72 horas entre as aplicações. Entre as aplicações os elementos eram mantidos em recipientes individuais em ambiente com 100% de umidade relativa. O grupo controle não sofreu tratamento clareador e permaneceu em umidade relativa durante o período correspondente ao tratamento clareador. Para a determinação da resistência coesiva e análise morfológica da dentina clareada, imediatamente após o tratamento clareador, foram obtidos espécimes da dentina vestibular interna. De cada bloco foram obtidas fatias de dentina (0,8 mm de espessura). Foi realizada uma constrição na região da dentina interna de cada fatia para redução da região central, produzindo uma área de secção transversal de 0,7 mm2. Após 24 horas de imersão em água, os espécimes foram testados através de ensaio de microtração. Os resultados obtidos foram estatisticamente analisados. Blocos adicionais de cada grupo foram preparados para a avaliação da estrutura da dentina intacta ou desmineralizada clareada, através da Microscopia de Transmissão Eletrônica (MET). Os resultados da primeira parte da pesquisa indicam que a resistência à tração (RT) da dentina intacta e pré-condicionada diminuiu após todos os tratamentos com agentes intracoronários. Foram observadas alterações morfológicas através da análise ultra-estrutural do substrato clareado. Na segunda parte dessa pesquisa, foi determinada a resistência de união (RU) da dentina-compósito após o tratamento clareador. A RU foi determinada imediatamente, 7 dias e 14 dias após o tratamento clareador interno. Após a realização dos tratamentos clareadores intracoronários descritos anteriormente, blocos da dentina interna foram obtidos e aleatoriamente subdivididos em três grupos: (0) RU imediatamente após tratamento clareador; (7) RU testada após 7 dias do término do tratamento clareador e (14) RU à dentina testada após 14 dias do término do tratamento clareador. Os blocos de dentina eram armazenados em solução remineralizante durante o período de espera e 24 horas antes do teste de microtração, eram removidos da solução e preparados para a microtração. Os blocos foram tratados com sistema adesivo de passo único com condicionamento ácido prévio e um bloco de compósito foi construído na superfície dentinária para o ensaio de microtração. Espécimes de cada grupo foram preparados para a avaliação da nanoinfiltração na dentina intacta ou pré-condicionada clareada, através da MET. Os resultados indicam que houve diminuição da resistência de união da dentina intacta e pré-condicionada tratada com agentes clareadores intracoronários, imediatamente após o tratamento. Decorridos 14 dias do tratamento clareador, a dentina intacta clareada apresentou aumento da resistência de união em todos os grupos, enquanto na dentina pré-condicionada previamente ao tratamento clareador, apenas o grupo tratado com perborato de sódio apresentou aumento de resistência de união semelhante ao controle. A interface adesiva demonstrou nanoinfiltração imediatamente após o tratamento clareador, em todos os grupos observados (dentina intacta e précondicionada), sendo que após 14 dias do término do tratamento clareador, foi observado diminuição no padrão de nanoinfiltração desta interface / Abstract: Section A: Effects of bleaching agents on dental enamel Since the introduction of the nightguard vital bleaching technique using 10% carbamide peroxide (10% CP), reports have evaluated the effects of bleaching agents on human enamel. Evidences show that CP is able to alter the composition and morphology of enamel substrate. In order to reduce the adverse effects produced by these agents on enamel surface, manufactures have added fluoride and other ions in the bleaching agent formulation. However, little is known about the effects of these agents on sound and early caries affected enamel. Therefore, the aim of this study is to evaluate sound and early caries affected enamel 10% CP bleaching with the addition or not of fluoride and calcium ions. Enamel fragments obtained from bucal and lingual third molars surfaces were used and prepared to initial microhardness measurement. After selection of the specimens, half of them were submitted to enamel demineralization in order to produce early caries on this substrate. A new microhardness measurement was performed after enamel demineralization and the phosphate concentration of sound and demineralized enamel was determined by means of Fourier Transformed Raman Spectroscopy (FTRS). Sound and early caries affected enamel were randomly divided into six experimental groups (n=10): (PLA) Placebo; (W) Whiteness (10% PC); (O) Opalescence F (10% PC); (PN) Pola Night F(10% PC) and experimental bleaching agents (F) 10% PC + 0.5% F e (Ca) 10% PC + 0.2% Ca. Bleaching was carried out during 6 hours a day and after each application, specimens were kept in remineralizing solution until the next bleaching application. Bleaching treatment was performed during 12 days. On the 1st, 6th and 12th days of bleaching, microhardness measurements were performed and the rinsing water was used to determine the concentration of fluoride, calcium and inorganic phosphate by means of ion-selective electrode, atomic absorption spectroscopy and colorimetric analysis, respectively. After 12 days of bleaching, new FTRS analysis was performed and specimens were prepared to cross-sectional microhardness measurement and polarized light microscopy. The results showed that there was a decrease on sound and demineralized enamel microhardnessa after bleaching, specially when enamel was submitted to 10% CP application with no ionsaddition in its composition (Whiteness 10%). Chemical analysis indicated that there was a decrease in the ion concentration of sound and demineralized enamel after bleaching due to an increase in the content of calcium, fluoride and inorganic phosphorus in the rinsing water solution. Cross-sectional microhardness and polarized light microscopy confirmed the demineralization of enamel submitted to 10% CP with no fluoride or calcium additin (Whiteness 10%). High-concentrated calcium bleaching agent controlled demineralization on sound enamel, whereas, high-concentrated fluoride agent was important for the physical properties of early caries affected enamel Section B: Effects of intracoronal bleaching agents on dentin surface The aim of this study was to verify the influence of four intra-coronal bleaching agents on sound and etched dentin. Bovine incisors were prepared to intracoronal bleachingtreatment. Half of them were submitted to previous demineralization with 37% phosphoric acid for 15 seconds. The sound and etched incisors were randomly divided into 5 experimental groups: (C) Control ¿ no bleaching treatment; (PH 35%) hydrogen peroxide 35%; (PH 25%) hydrogen peroxide 25%; (PC 35%) carbamide peroxide 35% e (PS) sodium perborate mixed with distilled water. Bleaching agents were applied to the pulp chamber 4 times with a 72-hour interval among applications. Specimens were kept in individual recipients in humidity during bleaching. Control group was not bleached and remained in relative humidity during bleaching treatment. In order to determine the ultimate strength and structure of bleached intern dentin, immediately after bleaching, dentin fragments were obtained from internal bucal dentin. From each fragment, slices (0,8 mm thick) were obtained. Trimming was performed in the central area of each slice to produce a cross-sectional central area of 0,7mm2. After 24 hours, the ultimate strength of specimens was tested by means of microtensile test. Results were statistically analyzed. Additional fragments were treated and prepared to evaluation of sound and etched bleached dentin, through Transmission Electron Microscopy (TEM). The results of the first part of the study indicated that sound and etched ultimate strength decreased after intracoronal bleaching. Morphological alterations were observed through ultra-structural analysis (TEM). The second part of the research determined the bond strength of resin-dentin after bleaching. Bond strength was determined immediately, 7 and 14 days after intracoronal bleaching. After treatment of the specimens, according to previous descriptions, fragments obtained from bucal dentin were randomly divided into 3 groups: (0) Bond strength immediately after treatment; (7) Bond strength 7 days after bleaching treatment; (14) Bond strength 14 days after bleaching treatment. Specimens were kept in remineralizing solution and 24 hours before testing, they were removed from the solution and prepared to microtensile test. The fragments were restored with one-step total acid conditioning adhesive system and a composite block was build up on dentin surface to microtensile test.Results obtained were statistically analyzed. Additional specimens from each group were prepared to nanoleakage evaluation of sound and etched bleached dentin, by means of TEM. Bond strength of sound and etched bleached dentin decreased immediately after intracoronal bleaching. After 14 days of bleaching treatment, bond strength of sound bleached dentin increased for all groups, whereas for etched bleached dentin, sodium perborate was the only group with bond strength similar to control group. Sound and etched dentin of all treated and not-treated groups, presented nanoleakage immediately after bleaching. After 14 days, nanoleakage decreased for all groups tested. / Doutorado / Dentística / Doutor em Clínica Odontológica
192

Avaliação da eficacia de clareamento e do aumento de temperatura de fraqmentos dentais submetidos a tres sistemas clareadores, catalisados por diferentes fontes de lus / Influence of different light sources on the temperature rise and effectiveness of three bleaching agents

Lima, Débora Alves Nunes Leite, 1978- 14 August 2018 (has links)
Orientador: Jose Roberto Lovadino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T19:37:51Z (GMT). No. of bitstreams: 1 Lima_DeboraAlvesNunesLeite_M.pdf: 1094149 bytes, checksum: 7115932ab994079522229871a69214ce (MD5) Previous issue date: 2005 / Mestrado / Dentística / Mestre em Clínica Odontológica
193

Avaliação de diferentes catalisadoores no clareamento dental : estudo in vitro / Evaluation of different on tooth bleaching : in vitro study

Lima, Débora Alves Nunes Leite, 1978- 02 July 2008 (has links)
Orientador: Jose Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-11T12:44:55Z (GMT). No. of bitstreams: 1 Lima_DeboraAlvesNunesLeite_D.pdf: 595978 bytes, checksum: 9c2784969f094e3cb150fb69f46744b1 (MD5) Previous issue date: 2008 / Resumo: O objetivo deste estudo ¿in vitro¿ foi avaliar a eficácia do clareamento dental através da utilização de um gel contendo peróxido de hidrogênio em alta concentração associado a diferentes agentes catalisadores físicos e químicos. Para isso, o estudo foi dividido em 2 experimentos. Experimento 1- avaliou a eficácia do clareamento após tratamento com peróxido de hidrogênio 35 % (Whiteness HP Maxx) ativado por diferentes fontes de luz: Lâmpada halógena (no modo convencional e clareamento) (Optilux 501C, Demetron/Kerr), LED 1° geração (Ultrablue IV, DMC), LED/ laser de diodo (Ultrablue IV, DMC), LED 2° geração (no modo alta potência) (Bluephase 16i, Ivoclar Vivadent) e nenhuma fonte de luz (grupo controle); Experimento 2- avaliou a eficácia do clareamento em consultório ativado com catalisadores químicos e/ou físico: G1- peróxido de hidrogênio 35 % (Whiteness HP Maxx) + 20 % hidróxido de sódio; G2- peróxido de hidrogênio 35 % + 7 % bicarbonato de sódio; G3- peróxido de hidrogênio 38 % (Opalescence Xtra Boost); G4: peróxido de hidrogênio 35 % + lâmpada halógena; G5: peróxido de hidrogênio 35 % + 20 % hidróxido de sódio + lâmpada halógena; G6: peróxido de hidrogênio 35 % + 7 % bicarbonato de sódio + lâmpada halógena; G7: peróxido de hidrogênio 38 % + lâmpada halógena e G8: peróxido de hidrogênio 35 %. Para tanto, fragmentos dentais foram obtidos de terceiros molares humanos e aleatoriamente distribuídos em grupos (n=5) de acordo com o tratamento estipulado. A eficácia do clareamento foi avaliada através de um espectrofotômetro. Para tratar os fragmentos, foram realizadas três sessões de clareamento (sessões 1 a 3). Os resultados foram submetidos à Análise de Variância, seguido do Teste de Tukey (p<0,05). Verificou-se que, para ambas as fases, os grupos ativados e não ativados pelos diferentes sistemas catalisadores não diferiram significativamente entre si. Dessa forma, os sistemas catalisadores não melhoraram a efetividade do tratamento clareador de alta concentração / Abstract: The aim of this in vitro study was to evaluate the bleaching efficacy of high concentration bleaching agents activated by chemical or physical catalysts. For this, this study was divided in two parts: Experiment 1- evaluated the efficacy of tooth whitening after treatment with 35 % hydrogen peroxide (Whiteness HP Maxx) activated by different light-curing units: Halogen lamp (Conventional and Bleach mode) (Optilux 501C, Demetron/Kerr), LED 1st generation (Ultrablue IV, DMC), LED/ diode laser (Ultrablue IV, DMC), LED 2nd generation (Bluephase 16i, Ivoclar Vivadent) , and no light source (control group); Experiment 2- analysis of chemical and physical catalysts: G1- 35 % hydrogen peroxide (Whiteness HP Maxx) + 20 % sodium hydroxide; G2- 35 % hydrogen peroxide + 7 % sodium bicarbonate; G3- 38 % hydrogen peroxide (Opalescence Xtra Boost); G4: 35 % hydrogen peroxide + Halogen lamp; G5: 35 % hydrogen peroxide + 20 % sodium hydroxide + halogen lamp; G6: 35 % hydrogen peroxide + 7 % sodium bicarbonate + halogen lamp; G7: 38 % hydrogen peroxide + halogen lamp and G8: 35 % hydrogen peroxide. Blocks obtained from human molars were randomly divided into groups (n=5) in accordance with bleaching treatments. The efficacy of bleaching was measured using a spectrophotometer. Three bleaching sessions were performed (sessions 1 to 3). The results were submitted to ANOVA followed by the Tukey test (p<0.05). For both experiments, activated vs. non-activated bleaching did not differ significantly for all the times tested. In conclusion, the activating systems did not improve the whitening effectiveness / Doutorado / Dentística / Doutor em Clínica Odontológica
194

Avaliação clínica de diferentes técnicas de clareamento de dentes polpados quanto à efetividade durante 12 meses / Clinical evaluation of effectiveness for different techniques of extrinsic bleaching

Juliana Felippi David e Goés de Azevedo 30 September 2009 (has links)
Objetivos: Este estudo in vivo avaliou comparativamente diferentes técnicas de clareamento de dentes polpados, quanto ao grau de mudança de cor e estabilidade do tratamento num período de doze meses, sensibilidade dentinária e o condicionamento ácido prévio ao clareamento. Métodos: Quarenta e cinco voluntários foram selecionados, de acordo com os critérios de inclusão e exclusão, e divididos aleatoriamente em 5 grupos (n=15). No clareamento em consultório, apenas na hemi-arcada direita (inferior e superior), o gel clareador foi ativado com uma fonte de luz híbrida enquanto no outro lado o gel não foi ativado, assim um mesmo voluntário participou de dois grupos. Além disso, um primeiro pré-molar superior direito ou esquerdo foi condicionado previamente ao clareamento com ácido fosfórico a 37% durante 15s. G1- Lase Peroxide (DMC Equipamentos), a base de peróxido de hidrogênio (PH) a 35% + duas ativações do gel com luz híbrida (LED e Laser de Diodo) (Whitening Lase II DMC Equipamentos) por três minutos e intervalo de 1min; em três aplicações; G2- Lase Peroxide em três aplicações de 15min e intervalos de 15mim; G3 - Opalescence Xtra Boost (Ultradent), a base de PH a 38% + duas ativações do gel com luz híbrida por três minutos e intervalo de 1min; em três aplicações; G4- Opalescence Xtra Boost em três aplicações de 15min e intervalos de 15mim; G5 - Opalescence PF (Ultradent), a base de peróxido de carbamida (PC) a 15%, 2 horas diárias por 10 dias. A avaliação da cor quantitativamente foi realizada com o espectofotômetro Vita EasyShade (Vita), antes do clareamento e após 24horas, 1 semana, 6 e 12 meses. A diferença de cor (_E) foi mensurada através do programa CIELab. A sensibilidade dentinária foi avaliada por meio do questionário VAS antes, imediatamente após o clareamento, 24 horas e uma semana. Resultados: A análise estatística não revelou nenhuma diferença estatística significante entre os grupos com e sem ativação do gel com luz híbrida. Diferença estatística foi observada entre os resultados após 24h, 1 semana e 1, 6 e 12 meses para todos os grupos experimentais. O clareamento em consultório utilizando o Lase Peroxide mostrou um aumento significante na sensibilidade quando comparado com o clareamento caseiro. O Lase Peroxida utilizado com luz híbrida e condicionamento prévio do esmalte demonstrou aumento significante da alteração de cor. Conclusão: Pode-se concluir que todas as técnicas e agentes clareadores usados são efetivos no clareamento dental. O uso de condicionamento ácido prévio ao clareamento aumenta o grau clareamento dos dentes. / Objectives: This study was evaluated color change and stability and tooth sensitivity in patients submitted to different bleaching techniques. Methods: Forty five patients were selected according to inclusion/exclusion criteria and divided in five groups (n=15). A half-mouth design was conducted to compare two in-office bleaching techniques with the same product and the effect of acid condition before treatment. G1: 35% hydrogen peroxide (HP) (Lase Peroxide, DMC Equipments) + hybrid light (LED + Diode Laser) Whitening Lase II (DMC equipments); G2: 35%HP; G3: 38%HP, X-tra Boost (Ultradent) + hybrid light; G4: 38%HP and G5: 20% Carbamide Peroxide (PC), Opalescence PF (Ultradent). For G1 and G2, PH was applied on the enamel surface for three consecutive times and activated by hybrid light during 6 min; G2 and G4, PH was applied on the enamel surface for three consecutive times during 15min and interval of 15min; G5, 15% PC for 2 hours daily during 10 days at home. The spectrophotometer VITA Easyshade (VITA) was used for color change, before the treatment and 24h, 1 week, 1, 6 and 12 months after. Color differences (_E) were assessed by means of the CIELab Program. VAS questioner was used for sensitivity tooth before the treatment and immediately, 24h and 1 week after. Results: The statistical analysis did not reveal any significant difference between activated or not by hybrid light. Statistical difference was observed between the results after 24h, 1 week and 1, 6 and 12 months, for both experimental groups. In-office bleaching with Lase Peroxide showed significant increase tooth sensitivity compared to home bleaching. Lase Peroxide with hybrid light and acid condition showed a significant increase in color change. Conclusion: It could be concluded that all the techniques and bleaching agents used are effective for dental bleaching. The use of acid condition before bleaching increase color chance.
195

Estudo in vitro da variação do pH de agentes clareadores e seu efeito sobre o desgaste e rugosidade superficial do esmalte bovino após escovação simulada / Variation of pH bleaching gels, wear and roughness of bovine enamel after tooth brushing abrasion test.

Ana Carolina Trentino 20 May 2011 (has links)
Este estudo in vitro avaliou a variação do pH de géis clareadores à base de peróxido de hidrogênio de diferentes concentrações e seu efeito sobre o esmalte bovino submetido à escovação simulada. Fragmentos de esmalte de dentes bovinos com 1,5cm x 0,5cm x 0,4cm, receberam o tratamento clareador e a escovação em uma metade, ficando a outra como controle; foram divididos aleatoriamente em nove grupos (n=10): G1 = controle; G2 = Whiteness HP 35% - 3 sessões (3x15); G3 = Whiteness HP 35% - 3 sessões (1x45); G4 = Lase Peroxide 35% - 1 sessão (4x730) + ativação com luz híbrida LED/Laser; G5 = Lase Peroxide 25% - 1 sessão (4x730) + ativação com luz híbrida LED/Laser; G6 = Lase Peroxide 15% - 1 sessão (4x730) + ativação com luz híbrida LED/Laser; G7 = Whitegold Office 35% - 3 sessões (1x45); G8 = Whiteness HP Blue Calcium 35% - 3 sessões (1x40); G9 = Whiteness HP Blue Calcium 20% - 3 sessões (1x50). A rugosidade aritmética (Ra) inicial, após clareamento e após escovação foi determinada pela média (µm) de 3 leituras com o rugosímetro Hommel Tester T 1000. Os valores de pH foram determinados pelo peagômetro digital Sentron Model 1001 nos tempos inicial e final independente do número de aplicações ou de sessões. Os espécimes foram armazenados em saliva artificial por 7 dias, submetidos à 100.000 ciclos de escovação simulada. Após 24 horas o desgaste superficial foi determinado (µm) novamente com o rugosímetro Hommel Tester T1000. Os dados da análise de pH foram submetidos a ANOVA um critério e teste de Tukey (p<0,05) com diferenças estatísticas. O teste de Kruskal Wallis e Dunn (p<0,05) aplicado sobre a variação da rugosidade e desgaste apontou diferenças estatísticas entre os grupos. Os géis clareadores apresentaram uma tendência de diminuição dos valores de pH do tempo inicial para o tempo final. Os géis clareadores apresentaram um tendência de diminuição dos valores de pH do tempo inicial para o tempo final, assim como os géis com valores de pH mais próximos dos valores ácidos tendem a levar a superfície do esmalte à uma maior susceptibilidade ao aumento da rugosidade e desgaste superficial, quando submetido à escovação simulada. / This in vitro study evaluated the variation of the pH of bleaching gels, roughness and the wear on bovine enamel, after various in office bleaching protocols and brushing. Ninety fragments of enamel, measuring 15mm x 5mm, were randomly divided into nine groups (n=10) according to bleaching procedure: G1: control; G2: 35% hydrogen peroxide (HP) (Whiteness HP, FGM) 3x15, 3 sessions with one week between each; G3: 35% HP (Whiteness HP, FGM) 1x45, in 3 sessions; G4: 35% HP (Lase Peroxide, DMC) + hybrid light (HL) (LED/Diode laser, Whitening Lase II, DMC Equipments), 4x730 (6 of HL activation), in 1 session; G5: 25% HP (Lase Peroxide II, DMC) + HL, 4x730 (6 of HL activation), in 1 session; G6: 15% HP (Lase Peroxide Light, DMC) 4x730 (6 of HL activation), in 1 session; G7: 35% HP (Whitegold Office, Dentsply) 3x15, in 3 sessions; G8: 35% HP (Whiteness HP Blue Calcium, FGM) 1x40, in 3 sessions; G9: 20% HP (Whiteness HP Blue Calcium, FGM) 1x50, in 3 sessions. The pH values were determined using a pH meter (Sentron Model 1001, Sentron) during the initial and final gel application times. The surface roughness (Ra) was evaluated with a rugosimeter (Hommel Tester T 1000) before and after bleaching, and after brushing (100,000 strokes). The rugosimeter was used to evaluate wear surface after 24 hours brushing. The data were submitted to one-way ANOVA and Tukey tests for pH values, Kruskall Wallis and Dunns test in relation to wear and surface roughness (p<0.05). It could be concluded that the pH values tended to decrease from the initial to final bleaching. After tooth brushing, bleaching procedures with highly acidic products provided a significant increase in enamel wear and surface roughness.
196

Desproteinização do esmalte associada à técnica de remineralização no clareamento em consultório / Enamel deproteinization associated to remineralization technique on in-office bleaching

Mauricio Neves Gomes 27 September 2011 (has links)
Objetivo: avaliar cor, brilho, rugosidade e alterações ultraestruturais do esmalte dental clareado com peróxido de hidrogênio a 35 %, submetido ao tratamento prévio com agente desproteinizante, ou ao tratamento posterior com o agente remineralizador fosforopeptídeo de caseína/fosfato de cálcio amorfo (ACP-CPP). Material e Métodos: Os grupos experimentais foram: GC (controle/consultório): H2O2 a 35 % - 4 sessões de 8 min; GE1 (primer+consultório): NaOCl 5,25 % por 1 min, aplicação do H2O2 a 35 % como no GC; e GE2 (consultório+ACP): GC + ACP-CPP diariamente por 7 dias. Fragmentos contendo esmalte e dentina (n=8), obtidos de dentes bovinos, foram utilizados para avaliar cor, brilho e a rugosidade. Alteração de cor (E), parâmetros L* e b* foram determinados com colorímetro e o brilho superficial com glossímetro antes, imediatamente após (1h), 4 e 7 dias após o tratamento. Parâmetros de rugosidades, Ra, Rt e RSm, foram obtidos com perfilômetro de contato antes, imediatamente após o tratamento e 7 dias após os tratamentos. Os resultados de E, brilho superficial e rugosidade foram avaliados separadamente usando ANOVA 2 fatores e teste de Tukey (p=0,05). Para avaliar a alteração ultraestrutural, dentes pré-molares humanos, seccionados nos sentidos vestibulo-lingual e mesio distal foram observados em microscópio eletrônico de varredura, por emissão de campo, e realizada a quantificação de elementos químicos por EDS. Análise tridimensional da estrutura do esmalte foi realizada por microtomografia computadorizada (micro-CT) com resolução 11,24 m (n=8). Foram realizadas análises dos parâmetros estruturais: espessura estrutural (St.Th.), separação estrutural (St.Sp.) e índice de fragmentação (Fr.I.) antes e após os tratamentos em duas regiões: ROI 1= 56,2 m e ROI 2= 110,2 m, ambas a partir da superfície vestibular. Foi utilizado o teste t pareado para análise estatística de cada parâmetro estrutural. Resultados: Não houve diferença estatística entre os diferentes tratamentos de superfície para E, Ra e RSm. Imediatamente após o clareamento (1h) ocorreu maior aumento do L* e queda do brilho superficial que se manteve por 7 dias. O uso de agente desproteinizante em dentes bovinos não acentuou a redução do brilho do esmalte, mas a aplicação de ACP-CPP acarretou em maior perda brilho e aumento nos valores de rugosidade após 7 dias para Rt. A aplicação do agente desproteinizante previamente ao clareamento em dente humano revelou uma superfície mais lisa, sem alterar os parâmetros estruturais. Há uma maior quantidade de cálcio, formação de um manto de recobrimento após aplicação de ACP-CPP em torno dos prismas de esmalte, aumento de St.Th de 4,1m, menor espaçamento entre os cristais de hidroxiapatita e redução de St.Sp em 0,8 m e de Fr.I em 0,01 no ROI-1 após 7 dias. Conclusão: O uso de agente desproteinizante não altera a cor, brilho e a ultraestrutura inorgânica. A aplicação de ACP-CPP após a técnica de clareamento de consultório não contribui para alteração de cor, mas reduz o brilho e altera a ultraestrutura da porção mais externa do esmalte após 7 dias / Purpose: To evaluate color, gloss, roughness and ultrastructural changes of enamel bleached with 35% hydrogen peroxide, subjected to previous treatment with deproteinized agent, or later treatment with remineralizing agent casein phosphopeptide-amorphous calcium phosphate (CPP-ACP). Materials and Methods: The experimental groups were: GC (control + in-office): 35% H2O2 - 4 sessions of 8 min; GE1(primer+in-office): 5.25% NaOCl during 1 min before the application of 35% H2O2 as done in GC, and GE2 (in-office+ACP-CPP): GC + ACP-CPP, daily applied during 7 days. Enamel and dentin blocks (n=8), obtained from bovine tooth, were used to evaluate color, gloss and roughness. Color changes (E), L* and b* parameters were done with a colorimeter and surface gloss with a glossimeter, before, immediately after (1h), 4 and 7 days after treatment. Roughness parameters, Ra, RT and Rsm, were done with a contact perfilometer before, immediately after and 7 days after treatments. ANOVA two-way and Tukeys test were performed to evaluate E, gloss and roughness separately (p=0.05). To access human pre-molar ultrastructural changes, teeth were cross-sectioned buccal-lingual and disto-mesio observed by scanning electron microscope, field emission gun, EDS to quantify chemical elements. Enamel three-dimensional images were analysed with microcomputed tomography (micro-CT) with resolution 11,24m (n=8). Structural parameters were analyzed: structural thickness (St.Th.), structural separation (St.Sp.) and fragmentation index (Fr.I.) before and after treatments in two regions of interest:ROI 1= 56,2m and ROI 2= 110,2 m, both from buccal surface. Paired t-test was done for analyses of each structural parameter. Results: There was no statistical difference among surface treatments to E, Ra and Rsm. Immediately after bleaching (1h) occured highest L* increase and decrease of surface gloss which remained until 7 days. Deproteinized agent applied on bovine tooth not emphasized enamel gloss reduction, but the CPP-ACP has resulted in a higher gloss reduction and roughness increase (Rt parameter) after 7 days. Deproteinized agent application previous to in- office bleaching observed a smooth surface, without structural parameters changes. There is a greater calcium quantity, forming a cover mantle after CPP-ACP application around enamel prisms, St.Th increase of 4,1m, less spacing between hydroxyapatite crystals and reductions of St.Sp of 0,8 m and Fr.I of 0,01 on ROI-1 after 7 days. Conclusion: Application of deproteinized agent does not change bovine enamel color, gloss and human enamel inorganic ultrastructure. CPP-ACP application after in-office bleaching does not contribute to color change, but decrease gloss of bovine enamel and change human enamel outermost ultrastructure portion after 7 days.
197

Monitoramento do processo de desmineralização e remineralização do esmalte dental humano durante e após o clareamento dental / Monitoring de-remineralizaton process on human enamel during and after dental bleaching

Alessandra Pereira de Andrade 25 August 2009 (has links)
Este estudo in situ tem como proposta geral monitorar os processos de desmineralização e remineralização do esmalte dental humano durante e após o clareamento dental e como objetivos específicos: avaliar se o processo de desmineralização e remineralização do esmalte dental é influenciado pela utilização de agentes clareadores com diferentes composições e estimar o período necessário para que o esmalte dental clareado atinja os níveis de mineralização evidenciados anteriormente ao início do tratamento clareador. Dez voluntários participaram deste estudo utilizando dispositivos intra-orais contendo quatro fragmentos de esmalte dental humano cada que foram submetidos aos seguintes tratamentos: G1 - peróxido de hidrogênio 35% (Pola Office, SDI); G2 - peróxido de hidrogênio 7,5% (Pola Day, SDI); G3 - peróxido de hidrogênio 7,5% (Day White ACP, Discus Dental); G4 - ácido fosfórico 35% (Condicionador de ácido fosfórico 3M ESPE Scotchbond 3M ESPE). O período do estudo compreendeu 21 dias entre tratamento e monitoramento que foi realizado pelo método de fluorescência do tecido dental com o auxílio do equipamento QLF System. A análise estatística realizada pelo teste estatístico de ANOVA 2 fatores para mensurações repetidas e o teste de Tukey revelou haver diferenças estatísticas entre os tratamentos realizados e entre os tempos de mensuração. Após a realização do monitoramento do conteúdo mineral do esmalte dental durante e posteriormente ao término do tratamento clareador pode-se constatar que os agentes clareadores que apresentam composições químicas distintas ocasionaram diferentes níveis de desmineralização no esmalte dental humano, sendo que o composto ACP presente em um dos géis clareadores utilizados foi capaz de reduzir o processo de desmineralização durante o período de tratamento clareador. O período necessário para que o esmalte dental clareado atingisse os níveis de mineralização iniciais variaram em função do clareador utilizado, porém apenas o agente clareador que contém o composto ACP foi capaz de remineralizar completamente após 21 dias. / The overall proposal of this in situ study is to monitor the demineralization and remineralization process of human enamel during and after dental bleaching and its specific objectives are: to assess whether the process of demineralization and remineralization of enamel is influenced by the use of bleaching agents with different composition and estimate the time required to bleached enamel reaches the levels of mineralization observed prior to bleaching treatment. Ten volunteers participated of this study wearing intraoral devices containing four fragments of human enamel submitted to the following treatments: G1 - 35% hydrogen peroxide (Pola Office, SDI), G2 - 7.5% hydrogen peroxide (Pola Day, SDI); G3 - 7.5% hydrogen peroxide (Day White ACP, Discus Dental); G4 - 35% phosphoric acid (Scotchbond 3M ESPE, 3M ESPE). The study period comprised 21 days of treatment and monitoring. Monitoring was conducted by the quantitative light fluorescence method, with QLF System. Statistical analysis performed by the statistical two-way ANOVA for repeated measurements and Tukey tests demonstrated differences between treatments and between measurement times. Monitoring the enamel mineral content during and after the end of the bleaching treatment revealed that the bleaching agents with different chemical compositions resulted in different levels of human enamel demineralization and that, the ACP compound present in one of the bleaching agents used was able to reduce the demineralization process during the bleaching treatment. Time required for the bleaching human enamel reaches the initial levels of mineralization varied depending on the bleaching agent used, but only the bleaching agent containing ACP was able to completely remineralize enamel after 21 days.
198

Influência de materiais bioativos sobre a dureza, ultraestrutura e conteúdo mineral de dentes clareados: estudo in situ / Changes after whitening: bioactive materials benefits- in situ study

Helena Burlamaqui Pinheiro 03 August 2012 (has links)
Objetivo: Investigar in situ a influência de materiais bioativos sobre a superfície do esmalte e dentina clareados, utilizando o teste de dureza Knoop (KHN), microscópio por emissão de campo (FEG) e quantificação do conteúdo mineral por fluorescência do substrato dental (QLF). Material e Métodos: Vinte molares humanos intactos foram selecionados. Para KHN e FEG, foram necessários 10 dentes. Foram obtidos 6 espécimes da porção cervical de cada dente, contendo esmalte e dentina, e distribuídos entre os 5 grupos experimentais, mais um controle (n=10). O grupo controle (sem tratamento) foi utilizado para o FEG, pois neste tipo de análise há destruição da amostra, não sendo possível a utilização de um mesmo espécime para obtenção de imagens nas fases antes e após o tratamento. Para o teste de dureza, as fatias tiveram os valores iniciais de dureza do esmalte e dentina medidos. Para o QLF, foram usados outros 10 dentes. Cada um foi seccionado em 5 fragmentos de esmalte superficial, retirados da porção coronária de cada dente. Metade de cada espécime foi protegida com verniz e a outra metade serviu para entrar em contato com os diversos tratamentos. Os fragmentos tiveram a quantificação mineral inicial medida pelo QLF. Todos os espécimes foram montados em retentores palatinos intraorais e usados por 10 voluntários durante 24h/dia, por 14 dias. Em cada dispositivo, eram aplicados os 5 diferentes tratamentos: 1: Opal, tratamento clareador com peróxido de carbamida (PC) 15% - Opalescence PF, Ultradent; 2: NiteWhite ACP, PC16% (Philips); 3: Opal + Bio (Biosilicato®, Vitrovita) misturados; 4: Opal Bio (Biosilicato® aplicado por 5 min, 1 vez por semana após clareamento); 5: Opal Rel ACP, Relief ACP (Philips) aplicado por 30 min por dia após clareamento. Em seguida, foram realizadas análises finais de KHN, FEG e QLF. Resultados: A análise estatística revelou que no grupo Opal houve redução significante dos valores de dureza em esmalte. No grupo Opal Bio, a aplicação do material bioativo não foi capaz de evitar a desmineralização do esmalte. Para os demais grupos, não houve alteração dos valores de dureza. Na dentina, o grupo Opal também causou diminuição na dureza. Nos grupos Opal Bio e Opal Rel ACP, a aplicação dos dois materiais bioativos não foi suficiente para evitar diminuição dos valores de dureza em dentina. Já nos grupos NW ACP e Opal + Bio, não foi observada desmineralização desse substrato. Os dados de dureza refletem os resultados observados na análise ultraestrutural do esmalte e da dentina, em que os grupos NW ACP e Opal + Bio apresentaram os melhores desempenhos em relação aos demais grupos. A análise por QLF não apresentou sensibilidade para detectar diferenças estatisticamente significantes entre os grupos e nem entre as fases inicial e final em nenhum dos grupos. Conclusão: No grupo Opal, observa-se desmineralização do esmalte e dentina clareados. A aplicação de Biosilicato® 1x por semana não foi suficiente para evitar alterações em esmalte e dentina. Relief ACP, aplicado diariamente após o tratamento clareador, foi capaz de evitar alterações em esmalte, mas não em dentina. A mistura de um gel clareador com um agente bioativo, como acontece nos grupos NW ACP e Opal + Bio, teve influência positiva em relação à dureza e morfologia da estrutura dental evitando sua desmineralização; nesses dois grupos, foram observados os melhores resultados tanto de dureza, quanto na análise ultraestrutural. / Objective: To Investigate in situ the influence of bioactive materials on whitened enamel and dentin surfaces using Knoop hardness test (KHN), field emission microscope (FEG) and quantitative light-induced fluorescence (QLF). Material and Methods: Twenty intact human molars were selected. Ten teeth for KHN and FEG were used. Six specimens were obtained from the cervical portion of each tooth, containing enamel and dentin. The slices were distributed into five experimental groups and one control (n=10). The control group (no treatment) was used for the FEG images, as this type of analysis destroys the sample, making it impossible to use the same specimens for before and after treatment images. For the hardness test, the enamel and dentin baseline Knoop hardness were measured for each slice for the control group and the five experimental groups. For QLF the other 10 teeth were used, each one sectioned into 5 superficial enamel slices. Half of each specimen was protected with varnish and the other half used to be in contact with the different treatments. The specimens had their baseline mineral content values measured by QLF. All specimens were mounted on intra-oral palatal retainers, which were used by 10 volunteers during 24h/day for 14 days. On each retainer five different treatments were applied: 1: Opal, whitening treatment (WT) with Opalescence PF, 15% carbamide peroxide (CP) (Ultradent); 2: NW ACP, whitening treatment with NiteWhite ACP, 16% CP (Philips); 3: Opal + Bio (Biosilicate®, Vitrovita) mixed; 4: Opal Bio (Biosilicate® applied for 5 minutes once a week after WT; 5: Opal Rel ACP, Relief ACP (Philips) applied 30 min per day after WT. Afterward, further KHN, FEG and QLF analysis were performed. Results: A statistical analyses revealed that the Opal group had a significant enamel hardness decrease. In the Opal Bio group, the application of the bioactive material was not able to prevent enamel demineralization. For the other groups changes in the hardness values were not observed. The Opal group also caused hardness decrease in the dentin. In the Opal Bio and Opal Rel ACP groups the application of the two bioactive materials was not enough to prevent the dentin hardness decrease. In the NW ACP and Opal + Bio groups demineralization of the substrate was not observed. The hardness data reflect the results observed in the ultra structural analysis of enamel and dentin, which groups NW ACP and Opal + Bio showed better performance compared to other groups. The QLF analysis was not sensitive enough to detect statistically significant differences between groups or between the initial and final phases in either groups. Conclusion: Enamel and dentin demineralization was observed for the Opal group. The application of Biosilicato® once a week was not enough to prevent enamel and dentin alterations. Relief ACP, applied daily after the whitening treatment, prevented changes in enamel but not in the dentin samples. The bioactive materials, when incorporated in the whitening gel (NW ACP and Opal + Bio groups), deliver positive benefits for tooth hardness and morphology, preventing demineralization; in both groups better hardness and morphology results were observed.
199

Avaliação da eficácia de agentes clareadores em diferentes temperaturas no esmalte e dentina = Effectiveness of bleaching agents at different temperatures on enamel and dentin / Effectiveness of bleaching agents at different temperatures on enamel and dentin

D'Arce, Maria Beatriz Freitas, 1976- 07 May 2013 (has links)
Orientador: Débora Alves Nunes Leite Lima / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T00:08:03Z (GMT). No. of bitstreams: 1 D'Arce_MariaBeatrizFreitas_D.pdf: 1270067 bytes, checksum: 7681e880d0d8a3c1dc2b3f8cfa2af016 (MD5) Previous issue date: 2013 / Resumo: O objetivo deste estudo foi avaliar a mudança de cor do esmalte e dentina após clareamento com géis de alta e baixa concentração em diferentes temperaturas. Cinquenta fragmentos dentais bovinos foram pigmentados em uma solução de chá preto. As amostras foram distribuídas aleatoriamente em 10 grupos (n=5) de acordo com o protocolo de clareamento: peróxido de carbamida 10% (PC) 4h/dia por 21 dias; peróxido de hidrogênio 6% (PH) com cálcio 1:30h/dia por 21 dias; PH 20% com cálcio 50 min/sessão com intervalo de 7 dias (3 sessões); HP 35% Blue com cálcio 40 min/sessão com 7 dias de intervalo (3 sessões); HP 35% Maxx 3x15 min/sessão com intervalo de 7 dias (3 sessões), e da temperatura de 22ºC e 41ºC. As amostras foram armazenadas em saliva artificial durante o todo experimento. A mudança de cor foi avaliada por meio de um espectrofotômetro (Konica Minolta CM 700d, Japan) e os dados expressos nos valores do sistema CIE Lab. As leituras de cor do esmalte e dentina foram feitas após a pigmentação e após o final de cada semana de clareamento. Ainda, a superfície de esmalte de 3 amostras de cada grupo foram avaliadas por meio de Microscopia Eletrônica de Varredura (MEV). Para a coordenada L*, os dados foram analisados por medidas repetidas e teste de Tukey-Krammer (5% de nível de significância) e os valores de ?E foram submetidos ao teste ANOVA 2 way e teste de Tukey (5% de nível de significância). Não houve diferença estatística significante entre as temperaturas avaliadas de 22ºC e 41ºC. À 22ºC, o PH 20% com cálcio mostrou os menores médias de reflectância diferindo estatisticamente de PC 10% e PH 6% com cálcio nas superfícies de esmalte e dentina. À 41ºC, nenhuma diferença estatística entre os agentes clareadores foi observada após três semanas de tratamento. O peróxido de hidrogênio 20% com cálcio foi menos efetivo na temperatura ambiente no esmalte e na dentina. Entretanto, a temperatura de 41ºC melhorou a eficácia deste agente clareador. Foram observadas alterações morfológicas na superfície de esmalte após o uso dos agentes clareadores, sendo que as maiores alterações ocorreram nos grupos tratados com géis com baixo pH / Abstract: The aim of this study was to evaluate the enamel and dentin color changes after bleaching using low- and high-concentration gels at different temperatures. Fifty bovine teeth fragments were stained in a black tea solution. The samples were randomly placed in 10 groups (n=5) according to the bleaching protocol: 10% carbamide peroxide (CP) 4h/day for 21 days; 6% hydrogen peroxide (HP) with calcium 1.30h/day for 21 days; 20% HP with calcium 50 min/session with seven-day intervals (3 sessions); 35% HP Blue with calcium 40 min/session with seven-day intervals (3 sessions); 35% HP Maxx 3x15 min/session with seven-day intervals (3 sessions), and a gel temperature of 22ºC and 41ºC. The samples were stored in artificial saliva at all times during the experiment. Color change effectiveness was evaluated using a spectrophotometer (Konica Minolta CM 700d, Japan) and data was expressed in CIE Lab System values. The enamel and dentin color measurements were made after staining and at the end of each week of bleaching sessions. In addition, three enamel surface samples from each group were evaluated using a scanning electronic microscope (SEM). For the L* coordinate, data was analyzed by repeated-measures and Tukey-Krammer Test (5% significance level) and ?E values were submitted to ANOVA 2-ways and Tukey tests (5% significance level). There were no statistical differences between the evaluated temperatures 22ºC and 41ºC. At 22ºC, the 20% HP with calcium showed the lowest reflectance means differing statistically from 10% CP and 6% HP with calcium on the enamel and dentin surfaces. At 41ºC, no statistical difference among bleaching agents was observed after three weeks of treatment. The 20% hydrogen peroxide with calcium was less effective at room temperature on enamel and dentin. However, the temperature at 41ºC improved the efficacy of this bleaching agent. Morphology changes on enamel surface were observed after using the bleaching agents, being more pronounced in the groups treated with low pH gels and high-concentration agents / Doutorado / Dentística / Doutora em Clínica Odontológica
200

Avaliação da alteração de cor de fragmentos dentais bovinos com diferentes espessuras e diferentes protocolos de clareamento / Color change evaluation of bovine dental fragments with different thicknesses and different bleaching protocols

D'Arce, Maria Beatriz Freitas, 1976- 18 August 2018 (has links)
Orientadores: José Roberto Lovadino, Débora Alves Nunes Leite Lima / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T18:39:32Z (GMT). No. of bitstreams: 1 D'Arce_MariaBeatrizFreitas_M.pdf: 969300 bytes, checksum: 3f731d566940391460ee1537cf2b7d4e (MD5) Previous issue date: 2011 / Resumo: O objetivo deste estudo foi avaliar a efetividade de géis clareadores de alta e baixa concentração no esmalte e dentina profunda. Foram utilizados 50 fragmentos dentais bovinos previamente manchados em solução de chá preto (6 dias) e divididos aleatoriamente em 10 grupos (n=5), de acordo a espessura do fragmento dental (2 mm e 3,5 mm) e com o agente clareador: Peróxido de Carbamida (PC) 10% (4h diárias / 21 dias); Peróxido de Hidrogênio (PH) 6% com cálcio (1:30h diária / 21 dias); PH 20% com cálcio (50 min por sessão / 3 sessões com 7 dias de intervalo); PH35% (3 x 15 min por sessão / 3 sessões com intervalo de 7 dias ); PH35% com cálcio (40 min por sessão / 3 sessões com intervalo de 7 dias). As amostras foram armazenadas em saliva artificial durante as 3 semanas de tratamento. A eficácia do tratamento clareador foi avaliada através de um espectrofotômetro (Konica Minolta CM 700d, Japan) e os resultados expressos nas normas do sistema CIE Lab. As leituras de cor do esmalte e dentina foram realizadas antes do manchamento, após o manchamento e após cada semana do tratamento clareador. Para a coordenada L* foi aplicado o teste de Tukey-Kramer (p<0,05). Para variável ?E foi aplicada análise de variância em esquema de parcelas subdivididas e teste de Tukey (p<0,05). Os resultados demonstraram que o clareamento do esmalte não dependeu da concentração do gel clareador. Para o clareamento da porção mais profunda da dentina, PH20% com cálcio e PH35% com cálcio apresentaram os menores valores de reflectância diferindo estatisticamente de PC10%. O peróxido de hidrogênio em altas concentrações com cálcio apresentou menor eficácia no clareamento em profundidade em relação ao peróxido de carbamida 10% / Abstract: This study evaluated the effectiveness of low- and high-concentration bleaching agents on enamel and deep dentin. Fifty stained bovine incisors fragments were randomized and placed into 10 groups (n=5), according to the sample thicknesses (2.0 mm or 3.5 mm) and bleaching agent: 10% carbamide peroxide (CP) (4 h a day/21 days); 6% hydrogen peroxide (HP) with calcium (1:30 h a day/21 days); HP 20% with calcium (50 min a day/3 sessions with a 7-day interval); HP 35% (3 x 15 min a day/3 sessions with a 7-day interval); HP 35% with calcium (40 min a day/3 sessions with a 7-day interval). The samples were stored in artificial saliva during the experiment. The efficacy of bleaching was measured using a spectrophotometer (Konica Minolta CM 700d, Japan) and the data was expressed in CIE Lab System values. The color measurement was evaluated during the initial analysis, after artificially staining with black tea and after each of the bleaching weeks. The L* coordinate data was submitted to analysis of variance and Tukey-Kramer tests (?=0.05) and the ?E values data was submitted for analysis of variance in a split-plot ANOVA and Tukey's test (?=0.05). The results demonstrated that none of the bleaching agents tested differed from the reflectance values on the enamel surface. For deep dentin, HP 20% with calcium and HP 35% with calcium showed the lowest reflectance values, which differed from CP 10%. The efficacy of bleaching the enamel surface was independent of gel concentration used. The high concentration hydrogen peroxide with calcium was less effective in deep dentin than the 10% carbamide peroxide / Mestrado / Dentística / Mestre em Clínica Odontológica

Page generated in 0.0656 seconds