• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 83
  • 11
  • 9
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 114
  • 63
  • 24
  • 17
  • 14
  • 14
  • 11
  • 10
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Perfil metabólico, pH abomasal, urinário e fecal e dosagem de pepsinogênio sérico em ovinos tratados com omeprazol oral / Metabolic profile, abomasal, urinary and fecal pH, serum pepsinogen dosage in sheep treated with oral omeprazole

Carolinne Broglio Deusdado 26 August 2016 (has links)
Para avaliar o efeito do uso oral de omeprazol em ruminantes adultos saudáveis, foram utilizados cinco ovinos machos, com dois anos de idade, hígidos e providos de cânula abomasal, que ou não receberam nada (grupo controle) ou receberam omeprazol oral em pasta, na dose de 4 mg/kg de peso vivo a cada 24 horas, durante 7 dias, em delineamento experimental de cross-over, com período de 'wash-out' de 7 dias. Diariamente os animais foram avaliados clinicamente e foram realizados o hemograma, a hemogasometria venosa; a mensuração dos eletrólitos, o perfil bioquímico, a concentração de pepsinogênio e o pH abomasal, urinário e fecal. Foi realizada, no último dia do período experimental a curva de 24 horas, com intervalo de duas horas, para o pH abomasal e o pepsinogênio sérico. Não houve efeito de tratamento para as variáveis analisadas, que permaneceram dentro do intervalo fisiológico para a espécie ovina. O uso do omeprazol na dose de 4 mg/kg de peso corporal durante sete dias, apesar de não aumentar o pH abomasal, diminuiu as concentrações de cálcio iônico e de cloro séricas / To evaluate the effect of oral omeprazole in healthy adult ruminants, five male sheep, two years old, healthy and provided with abomasal cannula, were used. Either received nothing (control group) or received oral omeprazole paste in dose of 4 mg /kg body weight every 24 hours for 7 days in experimental design of cross-over, with period of 'wash-out' of 7 days. Every day the animals were evaluated clinically and were performed the blood test, venous blood gas analysis; the measurement of electrolytes, biochemical profile, the concentration of pepsinogen and abomasal pH, urinary and fecal. It was held in last day trial period to 24 hours curve with an interval of two hours for the abomasal pH and serum pepsinogen. There was no treatment effect for the variables that remained within the physiological range for the sheep. The use of omeprazole at 4 mg / kg body weight for seven days, while not increasing the pH abomasal decreased the calcium ion concentration and serum chlorine
32

Modelagem para dimensionamento de tanque de escorva para instalações de bombeamento utilizando a Lei de Boyle

Bettini, Marcos de Oliveira [UNESP] 27 August 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-08-27Bitstream added on 2014-06-13T20:50:14Z : No. of bitstreams: 1 bettini_mo_me_jabo.pdf: 488030 bytes, checksum: a6e671590b570b472ce89e5ede065033 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A maioria das instalações de abastecimento de água utiliza bombas hidráulicas do tipo turbobombas. Esse tipo de bomba requer que o interior de sua carcaça e o da tubulação de sucção estejam preenchidos com água (escorvados), para que a sucção da água a partir do reservatório de captação possa ser efetivada. O escorvamento das bombas é conseguido instalando-as abaixo do nível de água do reservatório de captação (bomba afogada). Nos casos de instalações com bombas acima do nível do reservatório, há necessidade do uso de válvulas-de-pé, que têm partes móveis suscetíveis ao mau funcionamento por desgastes, quebras, sujeira ou outros problemas, que limitam a confiabilidade desse sistema, principalmente em caso de automação. Como alternativa ao uso da válvula-de-pé, foram estudados dois modelos de tanques escorva, testados no Laboratório de Hidráulica da FCAV - UNESP - Jaboticabal - SP. Avaliaram-se diferentes situações de altura manométrica de sucção, comprimento e diâmetro de tubulação de sucção e relações entre volume útil do tanque e volume do tubo de sucção, tendo-se concluído que: a) o volume do tanque de escorva é função do volume da tubulação de sucção e da altura manométrica de sucção; b) o volume do tanque de escorva pode ser calculado seguindo-se a Lei de Boyle, com uma percentagem de acréscimo no volume útil, que neste estudo foi cerca de 10% para o modelo 1 e cerca de 30% para o modelo 2. / The most of water supply installations uses hydraulic pumps type turbine pumps. This kind of pump must to have its casing body and suction pipe filled with water (primed) to be started. The priming can be done installing the pump underneath the suction reservoir water level. In the installations cases that the pump is above of water it is necessary to use foot valves to keep the pump primed. Foot valves have mobile parts, can be damaged or broke by use, dirty and others, that limits the reliability specially for automatic start-up of the system. As an alternative solution the current work in São Paulo State University Hidraulic Laboratory – Jaboticabal – Brazil, were evaluated two priming-tank models tested in different suction manometric heights, suction pipe diameters and relations between net tank volume and suction pipe volume. The conclusions show that: a) the priming tank volume is a function of the suction pipe volume and suction manometric height; b) the prime tank volume is calculated using Boyle equation with a percentage safety margin added in the net tank volume, that in this work was nearly to 10% for the model 1 and 30% for the model 2.
33

Bomba de calor para desumidificação e aquecimento do ar / Heat pump for dehumidifying and heating air

Luiz, Márcia Ramos 30 August 2007 (has links)
Submitted by Viviane Lima da Cunha (viviane@biblioteca.ufpb.br) on 2017-06-16T10:22:50Z No. of bitstreams: 1 arquivototal.pdf: 1008850 bytes, checksum: 2449c3ac92745b3cb932d4ea5dddd28b (MD5) / Made available in DSpace on 2017-06-16T10:22:50Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1008850 bytes, checksum: 2449c3ac92745b3cb932d4ea5dddd28b (MD5) Previous issue date: 2007-08-30 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Different forms of air treatment are used for food drying. It is the purpose of this work to describe both the implementation and instrumentation of a system of heat pump for dehumidifying and heating up the drying air under temperatures higher than room temperature but lower that those employed in resistance dryers promoting, in this way, better product quality. Our pump system consists of an evaporator, a condenser, a thermal expansion valve, and a fan. The heat pump makes use of the energy dissipated by both the condenser and the compressor to heat up the air dehumidified by the evaporator. Our device has been better characterized by its effectiveness in heating up the air as well as by its efficient, drying capacity. Sensors were installed at both the inlet and outlet of the device in order to control relative humidity, dry bulb temperature and velocity. Tests were accomplished to verify airflow velocity at 6,1 m/s and 5,7 m/s. For each case, measurements were taken every 15 min, with entering air parameters under atmospheric pressure with temperatures ranging from 27 and 32 ºC, and relative humidity ranging from 68 to 80%. Analyses of the same parameters were carried out at both the heat pump outlet and along the cooling cycle. An energy-exergetic analysis of the heat pump was completed. Simulations were made with the help of computer programs on EES (Engineering Equation Solver) platforms.For these simulations, the programs were developed based on the following: Law of Mass Conservation, and the First and Second Laws of Thermodynamics. It was then possible to put forward some suggestions for improving the drying process and its instrumentation. / Diversos tipos de tratamentos do ar têm sido utilizados para secagem de produtos alimentícios. Este trabalho, tem como objetivo a montagem e instrumentação de um sistema de bomba de calor para desumidificação e aquecimento do ar de secagem utilizando temperaturas maiores que a ambiente, porém menores que os secadores resistivos, o que favorece um produto com qualidade melhor. O sistema de bomba de calor consiste de um evaporador, um condensador, um compressor, uma válvula de expansão e um ventilador. A bomba de calor aproveita a energia dissipada pelo condensador e compressor para aquecer o ar desumidificado pelo evaporador. O aparato foi caracterizado pela verificação da capacidade de aquecimento do ar e sua eficiência para secagem. Foram instalados na entrada e na saída do equipamento, sensores de umidade relativa, de temperatura de bulbo seco e de velocidade. Os testes foram realizados para velocidades do fluxo de ar de 6,1 m/s e 5,7 m/s. Para cada caso, foram realizadas medições a cada 15 min, com parâmetros de entrada do ar na pressão atmosférica, temperatura entre 27 e 32 ºC e umidade relativa entre 68 e 80 %, e verificação dos mesmos parâmetros na saída da bomba de calor, como também do ciclo de refrigeração. Foi realizada uma análise energética e exergética da bomba de calor. As simulações foram feitas através de programas computacionais na plataforma EES (Engineering Equation Solver). Para estas simulações, foram desenvolvidos os programas baseados na Lei da Conservação da Massa, da Primeira e Segunda Leis da Termodinâmica e com os resultados encontrados são feitas sugestões para melhoria do processo e instrumentação deste.
34

Elaboração de um reator contínuo para síntese de biocombustível: avaliação experimental com sebo animal. / Elaboration of a continuous reactor for biofuel synthesis: experimental evaluation with animal tallow.

COSTA, Potí Oliveira Cortêz. 16 May 2018 (has links)
Submitted by Deyse Queiroz (deysequeirozz@hotmail.com) on 2018-05-16T14:53:03Z No. of bitstreams: 1 POTÍ OLIVEIRA CORTÊZ DOSTA - DISSERTAÇÃO PPGSA PROFISSIONAL 2015..pdf: 1109832 bytes, checksum: b9946c27427ba9fe3bba90b7b91d41cd (MD5) / Made available in DSpace on 2018-05-16T14:53:03Z (GMT). No. of bitstreams: 1 POTÍ OLIVEIRA CORTÊZ DOSTA - DISSERTAÇÃO PPGSA PROFISSIONAL 2015..pdf: 1109832 bytes, checksum: b9946c27427ba9fe3bba90b7b91d41cd (MD5) Previous issue date: 2015-07 / Em busca de alternativas para o aproveitamento de resíduos do abate animal foi estudado um protótipo de reator contínuo de custo-benefício acessível para uso popular na agroindustrial local, com fins de produzir biocombustível líquido. Bem como, avaliação experimental por meio deste aproveitamento com o sebo, adquirido nos abatedouros públicos e caseiros de Catolé do Rocha-PB, utilizando dois tipos de métodos, a saber: hidroesterificação e craqueamento térmico catalítico. O sistema foi construído em escala de laboratório, composto por materiais metálicos de aço inox e algumas conexões de silicone. O sistema foi composto por reator, trocador de calor e uma bomba periférica comercial de 1/4CV. O aquecimento foi efetuado por chama a gás, o fluxo, a temperatura e pressão foram monitoradas. O reator foi manufaturado resultando em um volume de 687,22 mL. A avaliação experimental do sistema proposto foi realizada introduzindo gordura animal, a qual foi extraída do sebo por duas técnicas, chapa elétrica e autoclave, buscando investigar o melhor rendimento. A autoclave foi mais significativa (75,7%). Posteriormente, a síntese do biocombustível com o método da hidroesterificação adotando o referido sistema, apresentou não conformidade operacional na conexão da saída do reator, visto que estas foram rompidas, devido à formação de vapor internamente, ocasionando retorno da mistura aquecida para a conexão com a bomba periférica. Esperava-se atingir temperatura de 260 ºC e pressão de 3bar, mas não foram atingidas. A segunda tentativa foi realizada buscando se atingir 200 ºC a 2bar, porém aos 157 ºC houve nova formação de refluxo. Diante deste fato, o sistema foi modificado, entre o reator e o trocador de calor a fim de se realizar um craqueamento termocatalítico, utilizando dois tipos de catalisadores independentemente, o carbonato de cálcio e a ferrita de níquel. Adotou-se a razão de 1:10 de catalisador/gordura injetados no sistema, pressão ambiente e temperatura acima de 600 ºC. Este método revelou bom funcionamento para o sistema idealizado, mas, ainda necessita ser aprimorado, em virtude do rendimento do bio-óleo ter sido inferior ao citado em literatura. Comparando a síntese entre os catalisadores o bio-óleo de carbonato de cálcio obteve melhor rendimento (49,51%), menor índice de acidez (1,45 mgKOH/g) porém o perfil térmico sugeriu maior presença de ácidos graxos combinados, moléculas de diacilglicerídeos e triacilglicerídeos. Já com ferrita de vii níquel teve menor rendimento 32,22%, maior índice acidez (5,36 mgKOH/g) e perfil térmico característico de apenas uma decomposição térmica sugerindo uma melhor ação catalítica. Ambos os bio-óleos apresentaram índice de acidez acima das normas da ANP. / In search of alternatives to recovery waste to animals slaughter, was studied a prototype of affordable continuous reactor for public use and local agribusiness, for purposes of producing liquid biofuels. As well, through the experimental evaluation of tallow use, acquired in public and homemade slaughterhouses Catolé Rocha-PB, using two types of methods, namely: hidroesterification and catalytic thermal cracking. The system was built on a laboratory scale, composed of metallic materials of stainless steel and some silicone connections. The system is composed of reactor, heat exchanger and pumps a commercial peripheral 1/4CV. Heating was affected by flame gas, and both flow with temperature and pressure were monitored. The reactor was manufactured resulting in a volume of 687.22 mL. The experimental evaluation of the system was carried out by introducing animal fat, which was extracted from tallow by two techniques, plates and autoclave techniques in order to investigate the best performance. The autoclave was more significant (75.7%). Thereafter, the biofuels synthesis was performed in the system, initially with the method of hidroesterification, in which one cannot observe operating line of the system, the reactor outlet connection, since these were broken due to formation of steam internally, causing returning the mixture heated for connecting to peripheral pump. Was expected reach 260 °C temperature and 3bar pressure, without success. A second attempt was carried out in order to achieve 2bar to 200 ºC, but at 157 ºC was new line of reflux. Given this fact, the system was modified between the reactor and the heat exchanger in order to hold a thermo catalytic cracking using two types of catalysts, independently, calcium carbonate and nickel ferrite. Adopted the ratio of 1:10 catalyst/fat injected into the system, ambient pressure and temperature above 600 °C. This method showed good run for the idealized system, but still needs to be improved since the yield of bio-oil was lower than that cited in the literature. Comparing the synthesis of the catalysts as calcium carbonate bio-oil obtained better yield (49.51%), acidity index (1.45 mgKOH/g), however the thermal profile suggested greater presence of fatty acids combined, diacilglicerídeos and triacilgerídeos molecules. Already with nickel ferrite had lower yield (32.22%), higher acidity index (5.36 mgKOH /g) and ix characteristic thermal profile of just one thermal decomposition suggesting a better catalytic action. Both bio-oils had acidity index above the standard of the ANP.
35

An?lise de confiabilidade de uma bomba centr?fuga: aplica??o na inje??o de ?gua para recupera??o de petr?leo

Santos, J?lio C?sar dos 17 September 2011 (has links)
Made available in DSpace on 2014-12-17T14:58:07Z (GMT). No. of bitstreams: 1 JulioCS_DISSERT.pdf: 3237837 bytes, checksum: 5158084ee6f945389663f9068eb38d4d (MD5) Previous issue date: 2011-09-17 / The oil industry`s need to produce with maximum efficiency, not to mention the safety and the environment aspects, encourages the optimization of processes. It makes them look for a level of excellence in acquisition of equipment, ensuring the quality without prejudice security of facilities and peoples. Knowing the reliability of equipment and that this stands for a system is fundamental to the production strategy to seeks the maximum return on investment. The reliability analysis techniques have been increasingly applied in the industry as strategy for predicting failures likelihood ensuring the integrity of processes. Some reliability theories underlie the decisions to use stochastic calculations to estimate equipment failure. This dissertation proposes two techniques associating qualitative (through expertise opinion) and quantitative data (European North Sea oil companies fault database, Ored) applied on centrifugal pump to water injection system for secondary oil recovery on two scenarios. The data were processed in reliability commercial software. As a result of hybridization, it was possible to determine the pump life cycle and what impact on production if it fails. The technique guides the best maintenance policy - important tool for strategic decisions on asset management. / A necessidade da ind?stria do petr?leo de produzir com o m?ximo de efici?ncia, sem esquecer os aspectos de seguran?a e meio ambiente, incentiva a otimiza??o dos processos produtivos, faz com que se busque atingir um n?vel de excel?ncia na aquisi??o de equipamentos, garantindo a qualidade sem preju?zo da seguran?a de instala??es e de pessoas. Conhecer a confiabilidade de um equipamento e o que esta representa para um sistema ? de fundamental import?ncia ? estrat?gia de produ??o quando se visa o m?ximo de retorno sobre o capital investido. As t?cnicas de an?lise de confiabilidade v?m sendo cada vez mais aplicadas na ind?stria como uma ferramenta estrat?gica para a predi??o da probabilidade de falhas e a garantia da integridade dos processos. Alguns fundamentos e teorias na ?rea de confiabilidade embasam as decis?es de se utilizar c?lculos estoc?sticos na estimativa de falhas de equipamentos. Esta disserta??o prop?e o uso de duas t?cnicas capazes de associar aspectos qualitativos (atrav?s de informa??es coletadas no campo com a opini?o de especialistas) e quantitativos (provenientes de bancos de dados de registros de falhas elaborados por empresas do segmento petrol?fero do mar do norte Europeu, mais conhecidos como Oreda). Este trabalho trata do uso dessas duas t?cnicas aplicadas em uma bomba centr?fuga, cujo sistema de inje??o de ?gua produzida ocorre em dois cen?rios poss?veis de opera??o : com manuten??o e sem manuten??o. Os dados obtidos nas avalia??es foram processados em software comercial de confiabilidade. Com o resultado desse hibridismo, foi poss?vel determinar o ciclo de vida da Bomba Centr?fuga e sua disponibilidade nesse per?odo e qual ser? o impacto na produ??o caso este venha a falhar. O uso dessa t?cnica permitir? orientar qual a melhor pol?tica de manuten??o ferramenta importante para a tomada de decis?es estrat?gicas na gest?o do ativo.
36

Desgaste de um rotor de ferro fundido cinzento revestido com camada de metal duro ap?s 1.000 horas de bombeamento de vinhoto operando na condi??o de cavita??o

Augusto, Ant?nio Roberto 01 September 2014 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-01-12T14:19:58Z No. of bitstreams: 1 AntonioRobertoAugusto_DISSERT.pdf: 15947966 bytes, checksum: 6137cc9dd87967a91d0ea2a7fd5913a0 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-01-17T13:19:05Z (GMT) No. of bitstreams: 1 AntonioRobertoAugusto_DISSERT.pdf: 15947966 bytes, checksum: 6137cc9dd87967a91d0ea2a7fd5913a0 (MD5) / Made available in DSpace on 2017-01-17T13:19:05Z (GMT). No. of bitstreams: 1 AntonioRobertoAugusto_DISSERT.pdf: 15947966 bytes, checksum: 6137cc9dd87967a91d0ea2a7fd5913a0 (MD5) Previous issue date: 2014-09-01 / A lideran?a mundial brasileira na obten??o de etanol derivado da cana de a??car pode ser associada ? produ??o do vinhoto, em uma raz?o de 10 a 18 litros de vinhoto para cada litro de etanol produzido durante o processo de destila??o. Nos cultivos da cana-de-a??car, esse vinhoto tem sido aplicado como adubo org?nico, onde o seu bombeamento ? um elemento cr?tico dessa cadeia produtiva. O objetivo deste trabalho foi investigar os principais mecanismos de desgaste de um rotor e de partes de uma bomba centr?fuga ap?s bombear vinhoto tratado em reator (pH 7,3?0.5). Um filme de 300?75 ?m de metal duro ? base de carboneto de tungst?nio-cobalto (WC-Co) foi aplicado ao rotor de ferro fundido cinzento da bomba atrav?s da t?cnica de aspers?o t?rmica HVOF. Considerando-se os trinta anos de experi?ncia do autor no projeto de sistemas de bombeamento, uma bancada para o bombeamento de vinhoto a 27?2oC foi desenvolvida em Laborat?rio para um servi?o de 1.000 horas atrav?s de ensaios durante dez horas di?rias e cont?nuas de uma bomba modelo INI 32-125 operando sob condi??es de cavita??o, conforme o c?lculo de NPSH. Um sistema de recircula??o do vinhoto foi adotado e controlado por uma v?lvula de descarga empregada comumente em processos industriais. Ap?s os ensaios, tanto o rotor revestido pelo metal duro como algumas partes n?o revestidas da bomba apresentaram um desgaste severo por cavita??o-eros?o, enquanto partes do rotor onde os efeitos da cavita??o s?o menores, o revestimento apresentou um desgaste moderado. / The Brazilian capability concerning to the world's leading producer of sugarcane ethanol can be joined together the vinasse production, which inherent amount discharged by distilling is from 10 to18 liters of vinasse per liter of ethanol produced. This vinasse has been applied in sugar-cane crops as organic fertilizer, where its pumping process is a critical element in this string. The aim of this work was investigate the main wear mechanisms of an impeller and parts of a centrifugal pump after pumping vinasse treated in reactor (pH 8,3?0,7). A tungsten carbide-cobalt (WC10Co4%Cr) film based hard metal of 360?35?m ?m was applied on the grey cast iron pump impeller by HVOF thermal aspersion. Based on the 30 years of experience of the author in the design and mounting of pumping systems, a test rig was developed in Laboratory for 1,000 hours of pumping tests of vinasse at 27?2oC for a continuous service during 10 hours by day for a pump model 32-125, working under cavitation conditions through the calculation of Net Positive Suction Head (NPSH), A recirculating system of the vinasse was adopted and controlled by a discharge valve usually employed in the industrial processes. After the tests, both the coated rotor as the uncoated parts of the pump showed severe wear by cavitation-erosion, while parts of the rotor where the effects of cavitation are smaller, the coating showed a moderate wear.
37

Associação entre o uso de inibidores da bomba de prótons e deficiência de magnésio : um corte transversal

Ascoli, Bruna Maria January 2012 (has links)
Introdução: Os inibidores de bomba de prótons (IBP) são medicamentos muito usados e estão indicados no tratamento de doenças pépticas. São drogas consideradas seguras, com pouca incidência de efeitos adversos. Entretanto há relatos recentes de séries de caso associando uso de IBP e deficiência de magnésio. O magnésio é um cátion de grande importância em diversos processos bioquímicos e a sua homeostase é regulada pela absorção intestinal, metabolismo ósseo e excreção renal. Objetivos: Devido ao pouco conhecimento atual em relação à associação entre hipomagnesemia e o uso crônico de IBP, o objetivo deste trabalho foi determinar a prevalência deste distúrbio eletrolítico e seus fatores associados em pacientes internados em duas equipes de Medicina Interna do Hospital de Clínicas de Porto Alegre (HCPA). Métodos: O estudo consistiu em um corte-transversal. Amostras de sangue e urina foram coletadas no período da manhã, após pelo menos 4 horas de jejum. Dados, tais como, idade, sexo, uso de IBP, hora e indicação de uso de IBP, o uso de outras medicações, e co-morbidades foram obtidos dos prontuários médicos. Pacientes com diarréia ou vômito, uso crônico de álcool, diabetes mellitus descompensado foram excluídos. Pacientes com uso crônico de laxantes, diuréticos e outras drogas relacionadas com a deficiência de magnésio, tais como a anfotericina B, aminoglicosídeos, e ciclosporina, também foram excluídos.Resultados: De setembro de 2010 a Junho de 2011 cerca de 800 pacientes foram admitidos na ala de emergência da medicina interna. Destes, 635 pacientes tinham critérios de exclusão, 14 pacientes se recusaram a participar, então 151 pacientes foram incluídos no estudo. Todos os pacientes tinham níveis normais de magnésio no soro. Não houve diferença entre a média dos níveis séricos de magnésio homens e mulheres. Não houve correlação entre a idade, níveis séricos de fósforo e potássio, com níveis séricos de magnésio. Albumina, creatinina, e cálcio foram positivamente correlacionados com níveis séricos de magnésio. Após a regressão linear múltipla, apenas os níveis séricos de albumina e creatinina foram independentemente associados com níveis séricos de magnésio. Quando a fração excrecional de Mg (FEMg) foi calculada após a exclusão dos pacientes que tinham níveis de creatinina sérica maiores que 1.3mg/dl, a média FEMg foi maior em usuários do PPI quando comparado com os outros pacientes apesar de magnésio no soro significa níveis foram semelhantes entre os grupos. Conclusão: A prevalência de hipomagnesemia foi menor do que a observada anteriormente. Isto pode ser devido aos critérios de exclusão deste estudo, que retirou pacientes com comorbidades, ou uso de drogas, comumente associados a hipomagnesemia. Os dados deste estudo mostraram que a associação entre uso IBP e hipomagnesemia é incomum, podendo ser devido a defeitos congênitos no metabolismo de magnésio, que em situações normais podem ser superados pelo organismo, mas na presença do IBP se torna evidente. Os mecanismos através dos quais esse efeito ocorre permanecem obscuros. As limitações deste estudo incluem a falta de um instrumento para medir a adesão ao uso do IBP e o tamanho da amostra. Nenhum paciente apresentou níveis baixos de magnésio, sugerindo que, para permitir o cálculo da prevalência desse efeito adverso, faz-se necessária uma amostra maior. / Background: Proton pump inhibitors (PPIs) are widely used and are indicated in the treatment of peptic diseases. They are considered safe, with low incidence of adverse effects. However there are recent reports of case series involving the use of PPI and magnesium deficiency. Magnesium is a cation of great importance in many biochemical processes and its homeostasis is regulated by intestinal absorption, bone metabolism and renal excretion. Objectives: Due to the limited knowledge regarding the association between hypomagnesemia and chronic use of PPIs, the objective of this study was to determine the prevalence of electrolyte disturbances and associated factors among hospitalized patients in two teams of Internal Medicine, Hospital de Clinicas de Porto Alegre (HCPA). Methods: A cross-sectional study was designed. Blood and urine samples were collected in the morning, after at least 4 hours of fasting. Data such as age, sex, use of PPIs, time and indication for use of PPIs, the use of other medications, and comorbidities were obtained from medical records. Patients with diarrhea or vomiting, chronic alcohol use, uncompensated diabetes mellitus were excluded. Patients with chronic use of laxatives, diuretics and other drugs related to magnesium deficiency, such as amphotericin B, aminoglycosides, and cyclosporine, were also excluded.Resultados: From September 2010 to June 2011 about 800 patients were admitted to the emergency ward of internal medicine. Of these, 635 patients had exclusion criteria, 14 patients refused to participate, so 151 patients were included in the study. All patients had normal levels of serum magnesium. There was no difference between the mean serum magnesium levels of men and women. There was no correlation between age, serum phosphorus and potassium levels with serum magnesium levels. Albumin, creatinine, and calcium were positively correlated with serum magnesium. After multiple linear regression analysis, only serum albumin and creatinine were independently associated with serum magnesium. When the fractional excretion of Mg (FEMg) was calculated after exclusion of patients who had serum creatinine greater than 1.3mg/dl, mean FEMg was higher in the PPI users compared with the non-users, although mean serum magnesium levels were similar between groups. Conclusion: The prevalence of hypomagnesemia was lower than that observed previously. This may be due to the exclusion criteria of this study that withdrew patients with comorbidities, or use of drugs, often associated with hypomagnesemia. Data from this study showed that the association between PPI use and hypomagnesemia is uncommon and may be due to defects in the metabolism of magnesium, which in normal situations can be overcome by the body but in the presence of IBP becomes evident. The mechanisms by which this effect occurs remain unclear. Limitations of this study include the lack of an instrument to measure adherence to the use of PPI and the sample size. No patient had low levels of magnesium, suggesting that, to allow the calculation of the prevalence of this adverse effect, it is necessary a larger sample.
38

Associação entre o uso de inibidores da bomba de prótons e deficiência de magnésio : um corte transversal

Ascoli, Bruna Maria January 2012 (has links)
Introdução: Os inibidores de bomba de prótons (IBP) são medicamentos muito usados e estão indicados no tratamento de doenças pépticas. São drogas consideradas seguras, com pouca incidência de efeitos adversos. Entretanto há relatos recentes de séries de caso associando uso de IBP e deficiência de magnésio. O magnésio é um cátion de grande importância em diversos processos bioquímicos e a sua homeostase é regulada pela absorção intestinal, metabolismo ósseo e excreção renal. Objetivos: Devido ao pouco conhecimento atual em relação à associação entre hipomagnesemia e o uso crônico de IBP, o objetivo deste trabalho foi determinar a prevalência deste distúrbio eletrolítico e seus fatores associados em pacientes internados em duas equipes de Medicina Interna do Hospital de Clínicas de Porto Alegre (HCPA). Métodos: O estudo consistiu em um corte-transversal. Amostras de sangue e urina foram coletadas no período da manhã, após pelo menos 4 horas de jejum. Dados, tais como, idade, sexo, uso de IBP, hora e indicação de uso de IBP, o uso de outras medicações, e co-morbidades foram obtidos dos prontuários médicos. Pacientes com diarréia ou vômito, uso crônico de álcool, diabetes mellitus descompensado foram excluídos. Pacientes com uso crônico de laxantes, diuréticos e outras drogas relacionadas com a deficiência de magnésio, tais como a anfotericina B, aminoglicosídeos, e ciclosporina, também foram excluídos.Resultados: De setembro de 2010 a Junho de 2011 cerca de 800 pacientes foram admitidos na ala de emergência da medicina interna. Destes, 635 pacientes tinham critérios de exclusão, 14 pacientes se recusaram a participar, então 151 pacientes foram incluídos no estudo. Todos os pacientes tinham níveis normais de magnésio no soro. Não houve diferença entre a média dos níveis séricos de magnésio homens e mulheres. Não houve correlação entre a idade, níveis séricos de fósforo e potássio, com níveis séricos de magnésio. Albumina, creatinina, e cálcio foram positivamente correlacionados com níveis séricos de magnésio. Após a regressão linear múltipla, apenas os níveis séricos de albumina e creatinina foram independentemente associados com níveis séricos de magnésio. Quando a fração excrecional de Mg (FEMg) foi calculada após a exclusão dos pacientes que tinham níveis de creatinina sérica maiores que 1.3mg/dl, a média FEMg foi maior em usuários do PPI quando comparado com os outros pacientes apesar de magnésio no soro significa níveis foram semelhantes entre os grupos. Conclusão: A prevalência de hipomagnesemia foi menor do que a observada anteriormente. Isto pode ser devido aos critérios de exclusão deste estudo, que retirou pacientes com comorbidades, ou uso de drogas, comumente associados a hipomagnesemia. Os dados deste estudo mostraram que a associação entre uso IBP e hipomagnesemia é incomum, podendo ser devido a defeitos congênitos no metabolismo de magnésio, que em situações normais podem ser superados pelo organismo, mas na presença do IBP se torna evidente. Os mecanismos através dos quais esse efeito ocorre permanecem obscuros. As limitações deste estudo incluem a falta de um instrumento para medir a adesão ao uso do IBP e o tamanho da amostra. Nenhum paciente apresentou níveis baixos de magnésio, sugerindo que, para permitir o cálculo da prevalência desse efeito adverso, faz-se necessária uma amostra maior. / Background: Proton pump inhibitors (PPIs) are widely used and are indicated in the treatment of peptic diseases. They are considered safe, with low incidence of adverse effects. However there are recent reports of case series involving the use of PPI and magnesium deficiency. Magnesium is a cation of great importance in many biochemical processes and its homeostasis is regulated by intestinal absorption, bone metabolism and renal excretion. Objectives: Due to the limited knowledge regarding the association between hypomagnesemia and chronic use of PPIs, the objective of this study was to determine the prevalence of electrolyte disturbances and associated factors among hospitalized patients in two teams of Internal Medicine, Hospital de Clinicas de Porto Alegre (HCPA). Methods: A cross-sectional study was designed. Blood and urine samples were collected in the morning, after at least 4 hours of fasting. Data such as age, sex, use of PPIs, time and indication for use of PPIs, the use of other medications, and comorbidities were obtained from medical records. Patients with diarrhea or vomiting, chronic alcohol use, uncompensated diabetes mellitus were excluded. Patients with chronic use of laxatives, diuretics and other drugs related to magnesium deficiency, such as amphotericin B, aminoglycosides, and cyclosporine, were also excluded.Resultados: From September 2010 to June 2011 about 800 patients were admitted to the emergency ward of internal medicine. Of these, 635 patients had exclusion criteria, 14 patients refused to participate, so 151 patients were included in the study. All patients had normal levels of serum magnesium. There was no difference between the mean serum magnesium levels of men and women. There was no correlation between age, serum phosphorus and potassium levels with serum magnesium levels. Albumin, creatinine, and calcium were positively correlated with serum magnesium. After multiple linear regression analysis, only serum albumin and creatinine were independently associated with serum magnesium. When the fractional excretion of Mg (FEMg) was calculated after exclusion of patients who had serum creatinine greater than 1.3mg/dl, mean FEMg was higher in the PPI users compared with the non-users, although mean serum magnesium levels were similar between groups. Conclusion: The prevalence of hypomagnesemia was lower than that observed previously. This may be due to the exclusion criteria of this study that withdrew patients with comorbidities, or use of drugs, often associated with hypomagnesemia. Data from this study showed that the association between PPI use and hypomagnesemia is uncommon and may be due to defects in the metabolism of magnesium, which in normal situations can be overcome by the body but in the presence of IBP becomes evident. The mechanisms by which this effect occurs remain unclear. Limitations of this study include the lack of an instrument to measure adherence to the use of PPI and the sample size. No patient had low levels of magnesium, suggesting that, to allow the calculation of the prevalence of this adverse effect, it is necessary a larger sample.
39

Desenvolvimento de um sistema de purificação de água com bomba de calor / Development of a water purification system with heat pump

Queiroz, Lorena Aires Lombardi 05 June 2011 (has links)
Orientador: Vivaldo Silveira Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-18T01:57:04Z (GMT). No. of bitstreams: 1 Queiroz_LorenaAiresLombardi_M.pdf: 3856550 bytes, checksum: 772ac0e513c805ef7e7a144496ffab9a (MD5) Previous issue date: 2011 / Resumo: O processo mais simples para que a água alcance pureza adequada é a destilação convencional, porém este método tem como inconvenientes seu alto gasto com energia elétrica e seu elevado consumo de água. Buscando alternativas para produzir água purificada com economia de energia elétrica e água de resfriamento, mas com produção quanto à pureza equivalente ao convencional, surge a possibilidade da elaboração de um sistema de purificação de água pela desumidificação do ar com o auxílio de uma bomba de calor. O equipamento projetado para a purificação de água opera segundo um ciclo termodinâmico de refrigeração e é composto por duas partes: uma bomba de calor por compressão de vapor, do tipo ar-ar acoplada em um duto de ar, e uma câmara, onde ocorre a umidificação do ar, com ar recirculado. Foram testados, ainda, dois tipos de umidificadores, com recheio de vidro e um nebulizador A água produzida pode ser considerada purificada já que apresentou valores de condutividade elétrica entre 4 e 5 µS/cm. A bomba de calor apresentou um melhor desempenho quando foi utilizado o nebulizador, já que os COP obtidos foram maiores do que os obtidos nos ensaios com recheio de vidro, referente à umidificação adiabática / Abstract: The simplest process for water to reach adequate purity is the conventional distillation, however this method has drawbacks such as their high expense with electric energy and their high water consumption. Searching alternatives to produce purified water with saving energy and water cooling, but with production as purity as conventional, there is the possibility of developing a system for purifying water by dehumidification the air with a heat pump. The equipment designed for water purification operates on a thermodynamic cycle of cooling and is composed of two parts: a heat pump vapor compression, the type air-air coupled into an air duct, and a chamber where it occurs humidifying the air, with recirculated air. Were tested also two types of humidifiers, with filling of glass and a sprayer. The water produced can be considered as purified, since it showed electrical conductivity values between 4 and 5 ms / cm. The heat pump showed a better performance when the spray was used, since the COP obtained were higher than those obtained in tests with a filling of glass on the adiabatic humidification / Mestrado / Engenharia de Alimentos / Mestre em Engenharia de Alimentos
40

ResistÃncia a azÃlicos em candida spp. de origem veterinÃria: um fenÃmeno mediado por bombas de efluxo / AZOLE RESISTANCE IN CANDIDA SPP. FROM VETERINARY SOURCES: AN EFFLUX-MEDIATED PHENOMENON

DÃbora Castelo Branco de Souza Collares Maia 15 December 2011 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / O monitoramento da sensibilidade antifÃngica em espÃcies de Candida de origem veterinÃria à uma prÃtica recente e os mecanismos envolvidos ainda nÃo foram completamente elucidados. Considerando que o arsenal de drogas antifÃngicas à limitado e que o fenÃmeno de resistÃncia tem se tornado mais freqÃente, a compreensÃo deste fenÃmeno e a busca por alternativas terapÃuticas se fazem necessÃrias. Dessa forma, o presente trabalho teve como objetivo monitorar a sensibilidade in vitro de Candida spp. oriundas de animais, com Ãnfase na resistÃncia aos azÃlicos mediada por bombas de efluxo e na avaliaÃÃo da atividade do imidazÃlico levamisol sobre o crescimento destas leveduras. Para tanto, em um primeiro momento, foram avaliados 126 isolados de Candida, sendo 19 C. albicans, 17 C. famata, 5 C. guilliermondii, 8 C. krusei, 29 C. parapsilosis, 48 C. tropicalis, dos quais 22 foram isolados de rapinantes, 32 de periquitos do sertÃo, 56 de papagaios, 7 de araras canindà e 3 de um ouriÃo-cacheiro. Todas as cepas foram submetidas ao teste de microdiluiÃÃo em caldo, ante a anfotericina B, itraconazol, fluconazol, segundo metodologia padronizada pelo Clinical Laboratory Standards Institute (documento M27-A3). As concentraÃÃes inibitÃrias mÃnimas (CIMs) variaram de 0,03125 a 2 Âg/mL, 0,125 a 250 Âg/mL e de 0,03125 a 125 Âg/mL para anfotericina B, fluconazol e itraconazol, respectivamente. Dos 126 isolados avaliados por microdiluiÃÃo, 33 (26,2%) foram resistentes aos azÃlicos, sendo 7 (5,6%) resistentes somente a fluconazol, 1 (0.8%) resistente somente ao itraconazol e 24 (19%) resistentes a ambas as drogas. Em um segundo momento, todas estas cepas resistentes aos derivados azÃlicos, mais 20 C. albicans e 3 C. tropicalis resgatadas da nossa coleÃÃo de leveduras resistentes de origem veterinÃria, foram submetidas ao teste de inibiÃÃo de bomba de efluxo com prometazina, perfazendo um total de 56 cepas resistentes a azÃlicos. Dessa forma, as CIMs de fluconazol e itraconazol sofreram reduÃÃes significativas de 2 a 250 e de 16 a 4000 vezes, respectivamente. Investigou-se, ainda, a atividade antifÃngica do levamisol contra 12 C. albicans, 12 C. krusei, 12 C. parapsilosis e 12 C. tropicalis, sendo obtidas CIMs e concentraÃÃes fungicidas mÃnimas que variaram de 0,58 a 2,34 mg/mL e de 2,34 a 9,37 mg/mL, respectivamente. Paralelamente, foi demonstrado que o levamisol inibe a formaÃÃo do biofilme de C. albicans e C. tropicalis, bem como interfere na manutenÃÃo do biofilme maduro. Os dados apontam que a resistÃncia aos derivados azÃlicos Ã, pelo menos em parte, mediada por bombas de efluxo, bem como demonstram o potencial antifÃngico do imidazÃlico levamisol e sua capacidade de inibir o biofilme de cepas de Candida spp. oriundas de animais. / Monitoring of the antifungal susceptibility of Candida species from veterinary sources is a recent practice and the mechanisms involved in antifungal resistance have not been completely elucidated. Considering that the antifungal arsenal is limited and that antifungal resistance has become more frequent, the comprehension of this phenomenon and the pursuit for therapeutic alternatives are necessary. Thus, the present work aimed at monitoring the in vitro susceptibility of Candida spp. isolated from animals, with emphasis on efflux pump-mediated azole resistance and on the evaluation of the effect of the imidazole levamisole on the growth of these yeasts. For such, in a first approach, 126 Candida isolates (19 C. albicans, 17 C. famata, 5 C. guilliermondii, 8 C. krusei, 29 C. parapsilosis, 48 C. tropicalis), out of which 22 were recovered from raptors, 32 from cactus parakeets, 56 from Amazon parrots, 7 from blue-and-gold macaws and 3 from a Brazilian porcupine. All isolates were submitted to broth microdilution test against amphotericin B, itraconazole and fluconazole, according to the methodology recommended by the Clinical Laboratory Standards Institute (document M27-A3). The MICs ranged from 0.03125 to 2 Âg/mL, 0.125 to 250 Âg/mL and 0.03125 to 125 Âg/mL for amphotericin B, fluconazole and itraconazole, respectively. Out of 126 evaluated isolates, 33 (26.2%) were resistant to azoles, with 7 (5.6%) isolates resistant to fluconazole, 1 (0.8%) isolate resistant to itraconazole and 24 (19%) resistant to both drugs. In a second approach, all these azole resistant isolates, plus 20 C. albicans and 3 C. tropicalis that were recovered from our collection of resistant yeasts from veterinary sources, were submitted to the efflux pump inhibition assay with promethazine, with a total of 56 azole resistant isolates. Thus, MICs for fluconazole and itraconazole significantly reduced from 2 to 250 times for fluconazole and from 16 to 4000 times for itraconazole. The antifungal activity of levamisole against 12 C. albicans, 12 C. krusei, 12 C. parapsilosis and 12 C. tropicalis, was also evaluated, and MICs and minimum fungicidal concentrations varying from 0.58 to 2.34 mg/mL and from 2.34 to 9.37 mg/mL were obtained, respectively. Parallelly, it was demonstrated that levamisole significantly inhibits biofilm formation and interferes with the maintenance of mature biofilms. These data show that azole resistance is partially mediated by efflux-pumps and demonstrate the antifungal potential of the imidazole levamisole and its capacity of inhibiting the biofilm of strains of Candida spp. from animals.

Page generated in 0.0336 seconds