• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 83
  • 10
  • 9
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 113
  • 62
  • 24
  • 17
  • 14
  • 14
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo do efeito magnetohidrodinâmico em um eletrólito a partir do uso de um dispositivo ejetor eletromagnético / Study of MHD effect on an electrolyte solution, using an electromagnetic ejector device

Luciano Pires Aoki 18 July 2011 (has links)
A magnetohidrodinâmica, ou simplesmente MHD, é um campo da ciência que estuda os movimentos de fluidos condutores submetidos a forças eletromagnéticas e une conceitos da fluidodinâmica e eletromagnetismo. Nos últimos anos, a MHD vem sendo aplicada em diversas áreas tecnológicas, desde a propulsão eletromagnética até dispositivos biológicos. Neste trabalho, são mostradas a construção e a operação de um dispositivo MHD, um canal retangular preenchido com um fluido eletrolítico conhecido como macrobomba, isento de partes mecânicas móveis. Os imãs geram um campo magnético externo e os eletrodos criam um campo elétrico, perpendicular ao escoamento, que move o fluido. O modelo MHD é calculado a partir das equações de Navier Stokes acopladas às equações de Maxwell para um fluido incompressível newtoniano. As forças eletromagnéticas que surgem resultam do produto vetorial da densidade de corrente e da densidade de fluxo magnético - essa é a força de Lorentz. Os resultados são apresentados em simulações 3D numéricas, assim como em dados experimentais. O objetivo é relacionar o campo magnético com o elétrico e com a quantidade de movimento produzida, e calcular a densidade de corrente e o perfil de pressão e de velocidade. Um perfil U e M de pressões e velocidades é esperado no experimento. Dados experimentais e computacionais são comparados para validação e posterior uso para futuros trabalhos. / Magnetohydrodynamics or simply (MHD) is a field of science that studies the movement of conductive fluids subjected to electromagnetic forces. Such a phenomenon brings together concepts of fluid dynamics and electromagnetism. Over the years, MHD has been encountered in a wide area of technological applications electromagnetic propulsion to biological devices. The present work didactically shows the construction (materials and equipment) and operation of an MHD device; a rectangular closed circuit filled with an electrolyte fluid, known as macro pumps, where a permanent magnet generates a magnetic field and electrodes generate the electric field, perpendicular to the flow, moving the fluid. The MHD model has been derived from the Navier-Stokes equation and coupled with the Maxwell equations for Newtonian incompressible fluid. Electric and magnetic components engaged in the test chamber assist in creating the propulsion of the electrolyte fluid. The electromagnetic forces that arise are due to the cross product between the vector density of current and the vector density of magnetic field applied. This is the Lorentz force. Results are present of 3D numerical MHD simulation for Newtonian fluid as well as experimental data. The goal is to relate the magnetic field with the electric field and the amounts of movement produced, and calculate de current density and fluid´s pressure and velocity. An u-shaped and m-shaped velocity and pressure profiles are expected in the experiment. Computational and experimental data are compared for validation and future analysis.
22

Hiroshima: a catástrofe atômica e suas testemunhas / Hiroshima: the atomic attack and its witnesses

Nakagawa, Cristiane Izumi 25 August 2014 (has links)
Ao longo das duas Guerras Mundiais, observou-se o rompimento da humanidade com as normas de conduta inauguradas pelo Iluminismo, legitimando a violência como algo intrínseco à sociedade moderna. Essa mudança de valores foi acompanhada pelo crescente investimento científico e tecnológico, que atingiu um elevado desenvolvimento durante o século XX e trouxe, como um de seus resultados, os maiores genocídios realizados pelos Estados autoritários em nome de seus interesses políticos e econômicos. A barbárie nos leva a considerar um elemento para a reflexão: as testemunhas. Essas corporificam a necessidade de um resgate da humanização, da retomada dos valores morais perdidos com a banalização da violência. Assim, o testemunho confronta a história e demonstra que o desenvolvimento tecnológico não é sinônimo de desenvolvimento humano. Pelo contrário, permitem questionar a verdadeira intenção das nações que, em busca de hegemonia, destroem maciçamente populações inteiras. Nesse contexto, emergem as seguintes questões: o que é o testemunho e qual a sua importância para a sociedade moderna? O que levou, historicamente, ao surgimento das testemunhas? Qual o contexto histórico que proporcionou o desenvolvimento da bomba atômica? Por que houve a necessidade, por parte das nações em guerra, de exterminarem milhares de pessoas, principalmente civis? Qual a consequência do rompimento das normas de civilidade pelas duas Guerras Mundiais? Para responder a essas perguntas, investigou-se o Museu Memorial da Paz de Hiroshima no que diz respeito a sua exposição permanente, seus objetivos no que se refere à luta contra o esquecimento da catástrofe atômica e à coleta de testemunhos. Após esse primeiro momento da pesquisa, procedeu-se ao estudo do contexto histórico que culminou nas atrocidades cometidas ao longo das duas Grandes Guerras, os resultados dos extermínios em massa para a sociedade moderna e, finalmente, o estudo sobre o trauma e o testemunho em relação aos sobreviventes do bombardeio atômico de Hiroshima / Throughout the two World Wars, a disruption between humankind and the standards of conduct inaugurated by the Enlightenment was observed, legitimizing violence as something intrinsic to modern society. This change in values was followed by the increasing scientific and technological investment, which reached a high development during the twentieth century and brought, as one of its results, the greatest genocides carried out by the authoritarian States on behalf of their political and economic interests. The barbarism leads us to consider an element for reflection: the witnesses. They embody the need for redemption of humanization and the resumption of the moral values, both lost in the trivialization of violence. Thus, the testimony confronts history and shows that technological development is not a synonymous for human development. On the contrary, they allow us to question the true intent of the nations that, in their quest for domination, massively destroy entire populations. In this context, the following questions arise: what is the testimony and what is its importance to modern society? Historically, what had led to the appearance of witnesses? What is the historical context that provided the development of the atomic bomb? Why was there the need, by the nations at war, to exterminate thousands of people, mainly civilians? What is the consequence of breaking the rules of civility by the two World Wars? To answer these questions, the Hiroshima Peace Memorial Museum was investigated regarding its permanent exhibition, its goals regarding the struggle against forgetting the atomic disaster and the gathering of testimonies. After this first stage of the research, it was proceeded the study of the historical context that culminated in the atrocities committed during the two Great Wars, the results for modern society of the mass exterminations and finally, the study of trauma and testimony regarding the survivors of the Hiroshima atomic bombing
23

Avalia????o de muta????es associadas a resist??ncia a Tigeciclina em isolados cl??nicos de Klebsiella pneumoniae produtoras de Carbapenemase do tipo KPC

Figueiredo, Fernanda Nomiyama 06 March 2018 (has links)
Submitted by Sara Ribeiro (sara.ribeiro@ucb.br) on 2018-04-16T14:40:02Z No. of bitstreams: 1 FernandaNomiyamaFigueiredoDissertacao2018.pdf: 2178476 bytes, checksum: 23f38c14567d00ff189eaef20f904495 (MD5) / Approved for entry into archive by Sara Ribeiro (sara.ribeiro@ucb.br) on 2018-04-16T14:40:47Z (GMT) No. of bitstreams: 1 FernandaNomiyamaFigueiredoDissertacao2018.pdf: 2178476 bytes, checksum: 23f38c14567d00ff189eaef20f904495 (MD5) / Made available in DSpace on 2018-04-16T14:40:47Z (GMT). No. of bitstreams: 1 FernandaNomiyamaFigueiredoDissertacao2018.pdf: 2178476 bytes, checksum: 23f38c14567d00ff189eaef20f904495 (MD5) Previous issue date: 2018-03-06 / Klebsiella pneumoniae is one of the main bacterial agents that may cause infections related to health care assistance. K. pneumoniae frequently carries the resistance gene K. pneumoniae carbapenemase (KPC). Currently, tigecycline can be considered one of the last therapeutic options for KPC, but reports of tigecycline-resistant KPC isolates are on the rise, being indicated as most common mechanism the increased AcrAB-TolC efflux pump system expression. However, molecular tigecycline resistance mechanisms associated to AcrAB-TolC still remains obscure. Thus, the main goal of this study was to verify if tigecycline resistance can be related to the presence of mutations in the regulatory genes of AcrAB-TolC, AcrR and RamR. Therefore, 32 K. pneumoniae isolates were used, identification and antibiogram performed using Vitek 2 systems. The minimum inhibitory concentrations were confirmed using E-test. Primers were designed in order to verify mutations within AcrR and RamR genes. PCR analysis showed that the mutations found within these genes were transversions (94% for AcrR and 90% for RamR) and transitions (6% for AcrR and 10% for RamR). Nevertheless among the mutations, no distinction between tigecycline susceptible and resistant isolates was found. Some of the transversions caused change in the amino acid encoding 6 in AcrR and 15 in RamR. Presence of these types of mutations evaluation can be seen as the first bacterial resistance study step, as it may be caused by oxidative damage for bacterial DNA, frequently caused by antibiotic selective pressure. Tigecycline resistance found in this study`s clinical isolates may be associated to alterations in another genes that can trigger mechanisms associated to this antibiotic. / Klebsiella pneumoniae consiste em um dos principais agentes bacterianos causadores de infec????es relacionadas ?? assist??ncia ?? sa??de (IRAS). K. pneumoniae carrega frequentemente o gene de resist??ncia K. pneumoniae carbapenemase (KPC). Atualmente, a tigeciclina pode ser considerada uma das ??ltimas op????es terap??uticas para KPC, mas os relatos de isolados de KPC resistentes a tigecilina est??o em ascens??o, sendo a hiperexpress??o da bomba de efluxo AcrAB-TolC indicado como mecanismo mais comum. No entanto, os mecanismos moleculares de resist??ncia ?? tigeciclina associada ao AcrAB-TolC permanecem obscuros. Desta forma o objetivo deste trabalho foi verificar se a resist??ncia a tigeciclina pode estar relacionada ?? presen??a de muta????es nos genes ArcR e RamR, reguladores de AcrAB-TolC. Para tanto, 32 isolados de K. pneumoniae foram utilizados, sendo a identifica????o e o antibiograma feitos utilizando o sistema Vitek 2. A confirma????o das concentra????es inibit??rias m??nimas (CIMs) foram realizadas por E-test. Iniciadores foram desenhados para verifica????o de muta????es nos genes (AcrR e RamR). As an??lises por PCR mostraram que as muta????es encontradas nos genes AcrR e RamR foram substitui????es por transvers??o (94% e 90% para AcrR e RamR respectivamente) e transi????o (6% e 10% para AcrR e RamR respectivamente), por??m n??o foi identificada distin????o da presen??a de muta????es entre isolados sens??veis e resistentes a tigeciclina. Algumas tranvers??es ocasionaram mudan??a na codifica????o do amino??cido, sendo 6 em AcrR e 15 em RamR. A avalia????o da presen??a desses tipos de muta????es consiste em um primeiro passo para o estudo da resist??ncia bacteriana, j?? que pode ser causada por dano oxidativo ao DNA bacteriano, frequentemente ocasionado por press??o seletiva dos antibi??ticos. A resist??ncia a tigeciclina encontrada nos isolados cl??nicos do presente estudo, provavelmente pode estar associada a altera????es em outros genes desencadeadores de mecanismos de resist??ncia a tigeciclina.
24

Perfil metabólico, pH abomasal, urinário e fecal e dosagem de pepsinogênio sérico em ovinos tratados com omeprazol oral / Metabolic profile, abomasal, urinary and fecal pH, serum pepsinogen dosage in sheep treated with oral omeprazole

Deusdado, Carolinne Broglio 26 August 2016 (has links)
Para avaliar o efeito do uso oral de omeprazol em ruminantes adultos saudáveis, foram utilizados cinco ovinos machos, com dois anos de idade, hígidos e providos de cânula abomasal, que ou não receberam nada (grupo controle) ou receberam omeprazol oral em pasta, na dose de 4 mg/kg de peso vivo a cada 24 horas, durante 7 dias, em delineamento experimental de cross-over, com período de 'wash-out' de 7 dias. Diariamente os animais foram avaliados clinicamente e foram realizados o hemograma, a hemogasometria venosa; a mensuração dos eletrólitos, o perfil bioquímico, a concentração de pepsinogênio e o pH abomasal, urinário e fecal. Foi realizada, no último dia do período experimental a curva de 24 horas, com intervalo de duas horas, para o pH abomasal e o pepsinogênio sérico. Não houve efeito de tratamento para as variáveis analisadas, que permaneceram dentro do intervalo fisiológico para a espécie ovina. O uso do omeprazol na dose de 4 mg/kg de peso corporal durante sete dias, apesar de não aumentar o pH abomasal, diminuiu as concentrações de cálcio iônico e de cloro séricas / To evaluate the effect of oral omeprazole in healthy adult ruminants, five male sheep, two years old, healthy and provided with abomasal cannula, were used. Either received nothing (control group) or received oral omeprazole paste in dose of 4 mg /kg body weight every 24 hours for 7 days in experimental design of cross-over, with period of 'wash-out' of 7 days. Every day the animals were evaluated clinically and were performed the blood test, venous blood gas analysis; the measurement of electrolytes, biochemical profile, the concentration of pepsinogen and abomasal pH, urinary and fecal. It was held in last day trial period to 24 hours curve with an interval of two hours for the abomasal pH and serum pepsinogen. There was no treatment effect for the variables that remained within the physiological range for the sheep. The use of omeprazole at 4 mg / kg body weight for seven days, while not increasing the pH abomasal decreased the calcium ion concentration and serum chlorine
25

Bomba de calor ar/ar como sistema alternativo no aquecimento de aviários / Heat pump air/air as a heating alternative system in avian.

Tessaro, Alcione Rodrigo 21 September 2011 (has links)
Made available in DSpace on 2017-07-10T15:14:42Z (GMT). No. of bitstreams: 1 Tessaro_Texto_Completo.pdf: 1100731 bytes, checksum: a25e34be9cb4e5f90fe05aef925878f7 (MD5) Previous issue date: 2011-09-21 / This research aimed to create two prototypes for general heating of aviary cutting the first prototype mounted from a heat pump air/air, and the second prototype mounted from passing an electric heater. As a specific objective to assess the energy performance of prototype 1 simulating various scenarios of temperature and air velocities of passage in its condenser, and compare this performance with the electrical efficiency of the prototype 2. The experiment was conducted at the Experimental Station of agro-meteorological State University of West of Paraná, Cascavel Campus, a Latitude 24º 59' South, Longitude 53º 26' West and altitude of 682 m in the period june-july 2011. From the data collected in prototypes 1 and 2 were calculated their coefficient of performance and energy efficiency. The survey results showed that the coefficient of performance heat pump prototype 1 ranged from 1.22 to 2.58 as a function of temperature of -3 to 30°C in its evaporator and varying the speed of air passing through your condenser. The best efficiency achieved by the prototype 2 was 0.96. Comparing the prototype, it was found that prototype 1 consumed 54% less electricity to produce the same amount of heat that the prototype 2, considering the same conditions of temperature and air velocity of passage. In relation to its applicability poultry, it was estimated that prototype 1 is able to meet the calorific requirement and temperature of a batch of up to 396 chicks in its initial phase, while the prototype 2 supply a maximum of up to 148 chicks. To this end, it was concluded that the prototype 1 in this work, assembled from a heat pump air/air, demonstrated technically be a new alternative system for heating of poultry cut because its technology employed is energy-efficient, also achieved the characteristics of zootechnical from temperature and air velocities required in an aviary of court. / A presente pesquisa teve como objetivo geral criar dois protótipos para aquecimento de aviário de corte, o primeiro protótipo montado a partir de uma bomba de calor ar/ar, e o segundo protótipo montado a partir de um aquecedor elétrico de passagem. Como objetivo especifico avaliar o desempenho energético do protótipo 1 simulando diversas situações possíveis de temperatura ambiente e velocidades do ar de passagem em seu condensador, e comparar esse desempenho com a eficiência elétrica do protótipo 2. O experimento foi conduzido na Estação Experimental Agro-meteorológica da Universidade Estadual do Oeste do Paraná, Campus de Cascavel, a uma Latitude 24º59 Sul, Longitude de 53º26 Oeste e altitude de 682 m, no período de junho a julho de 2011. A partir dos dados coletados nos protótipos 1 e 2 foram calculados os seus respectivos coeficiente de desempenho e eficiência energética. Os resultados da pesquisa mostraram que o coeficiente de desempenho da bomba de calor do protótipo 1 variou de 1,22 à 2,58 em função da variação da temperatura de -3 à 30oC no seu evaporador e da variação da velocidade do ar de passagem pelo seu condensador. A melhor eficiência alcançada pelo protótipo 2 foi 0,96. Na comparação entre os protótipos, verificou-se que o protótipo 1 consumiu 54% menos energia elétrica para produzir a mesma quantidade de calor que o protótipo 2, considerando as mesmas condições de temperatura ambiente e velocidade do ar de passagem aplicada. Em relação a sua aplicabilidade avícola, estimou-se que o protótipo 1 é capaz de suprir as necessidades caloríficas e de temperatura de um lote de até 396 pintainhos, em sua fase inicial, enquanto o protótipo 2 supri um máximo de até 148 pintainhos. Para tanto, concluiu-se neste trabalho que o protótipo 1, montado a partir de uma bomba de calor ar/ar demonstrou ser tecnicamente um novo sistema alternativo no aquecimento de aviários de corte, pois sua tecnologia empregada é energeticamente eficiente, além de alcançar as características zootécnicas de temperatura e velocidades do ar exigidas em um aviário de corte.
26

Bomba de calor ar/ar como sistema alternativo no aquecimento de aviários / Heat pump air/air as a heating alternative system in avian

Rodrigo Tessaro, Alcione 21 September 2011 (has links)
Made available in DSpace on 2017-07-10T15:14:42Z (GMT). No. of bitstreams: 1 Alcione Rodrigo Tessaro.pdf: 1100733 bytes, checksum: 63be0e820d7b5f4c86fcab5ed0bf8617 (MD5) Previous issue date: 2011-09-21 / This research aimed to create two prototypes for general heating of aviary cutting the first prototype mounted from a heat pump air/air, and the second prototype mounted from passing an electric heater. As a specific objective to assess the energy performance of prototype 1 simulating various scenarios of temperature and air velocities of passage in its condenser, and compare this performance with the electrical efficiency of the prototype 2. The experiment was conducted at the Experimental Station of agro-meteorological State University of West of Paraná, Cascavel Campus, a Latitude 24º 59' South, Longitude 53º 26' West and altitude of 682 m in the period june-july 2011. From the data collected in prototypes 1 and 2 were calculated their coefficient of performance and energy efficiency. The survey results showed that the coefficient of performance heat pump prototype 1 ranged from 1.22 to 2.58 as a function of temperature of -3 to 30°C in its evaporator and varying the speed of air passing through your condenser. The best efficiency achieved by the prototype 2 was 0.96. Comparing the prototype, it was found that prototype 1 consumed 54% less electricity to produce the same amount of heat that the prototype 2, considering the same conditions of temperature and air velocity of passage. In relation to its applicability poultry, it was estimated that prototype 1 is able to meet the calorific requirement and temperature of a batch of up to 396 chicks in its initial phase, while the prototype 2 supply a maximum of up to 148 chicks. To this end, it was concluded that the prototype 1 in this work, assembled from a heat pump air/air, demonstrated technically be a new alternative system for heating of poultry cut because its technology employed is energy-efficient, also achieved the characteristics of zootechnical from temperature and air velocities required in an aviary of court. / A presente pesquisa teve como objetivo geral criar dois protótipos para aquecimento de aviário de corte, o primeiro protótipo montado a partir de uma bomba de calor ar/ar, e o segundo protótipo montado a partir de um aquecedor elétrico de passagem. Como objetivo especifico avaliar o desempenho energético do protótipo 1 simulando diversas situações possíveis de temperatura ambiente e velocidades do ar de passagem em seu condensador, e comparar esse desempenho com a eficiência elétrica do protótipo 2. O experimento foi conduzido na Estação Experimental Agro-meteorológica da Universidade Estadual do Oeste do Paraná, Campus de Cascavel, a uma Latitude 24º59 Sul, Longitude de 53º26 Oeste e altitude de 682 m, no período de junho a julho de 2011. A partir dos dados coletados nos protótipos 1 e 2 foram calculados os seus respectivos coeficiente de desempenho e eficiência energética. Os resultados da pesquisa mostraram que o coeficiente de desempenho da bomba de calor do protótipo 1 variou de 1,22 à 2,58 em função da variação da temperatura de -3 à 30oC no seu evaporador e da variação da velocidade do ar de passagem pelo seu condensador. A melhor eficiência alcançada pelo protótipo 2 foi 0,96. Na comparação entre os protótipos, verificou-se que o protótipo 1 consumiu 54% menos energia elétrica para produzir a mesma quantidade de calor que o protótipo 2, considerando as mesmas condições de temperatura ambiente e velocidade do ar de passagem aplicada. Em relação a sua aplicabilidade avícola, estimou-se que o protótipo 1 é capaz de suprir as necessidades caloríficas e de temperatura de um lote de até 396 pintainhos, em sua fase inicial, enquanto o protótipo 2 supri um máximo de até 148 pintainhos. Para tanto, concluiu-se neste trabalho que o protótipo 1, montado a partir de uma bomba de calor ar/ar demonstrou ser tecnicamente um novo sistema alternativo no aquecimento de aviários de corte, pois sua tecnologia empregada é energeticamente eficiente, além de alcançar as características zootécnicas de temperatura e velocidades do ar exigidas em um aviário de corte.
27

Análisis de la energía geotérmica de baja temperatura en terrenos volcánicos. Aplicaciones a la construcción en Tenerife

Expósito Martín, María del Cristo 18 December 2015 (has links)
La energía geotérmica constituye una fuente inagotable de energía que puede ser extraída de la tierra por medio de bombeo de fluidos calentados en su interior, aprovechando su gran inercia térmica. Este intercambio de calor se realiza para proyectos geotérmicos de baja entalpía en pozos de energía o bien por medio del uso de aguas subterráneas. Para hacer uso del calor extraído es necesario integrar el sistema con una bomba de calor, que actuará como intermediaria entre el sistema de intercambio de calor o colector y sistema de distribución interno de la vivienda, aportando el complemento de energía necesario para acondicionar térmicamente el hogar. Este estudio consiste en el análisis y evaluación técnica, económica y legal de varias instalaciones geotérmicas de baja entalpía que se encuentran en funcionamiento, utilizadas para climatización de piscinas y aire acondicionado, en edificios dedicados al sector servicios como Hoteles, Centros Comerciales; y en un estudio de viabilidad en una Bodega en la que se propone la utilización de la energía geotérmica para la producción de frío y calor tanto para la obtención de vino como para la climatización y ACS en zonas varias. Los estudios se han realizado en la Isla de Lanzarote en lugar de la Isla de Tenerife ya que es donde podemos encontrar un mayor número de instalaciones de este tipo. No tenemos conocimiento de instalaciones de geotermia somera en la Isla de Tenerife, aunque vemos que es factible su utilización. La investigación incluye el seguimiento de varias instalaciones geotérmicas de baja temperatura mediante pozos que se encuentran en funcionamiento desde hace algunos años. Se llega a la conclusión de que técnicamente los sistemas geotérmicos de baja entalpía utilizados son factibles y permiten reducir costos. Los sistemas que utilizan aguas subterráneas, sistemas geotérmicos abiertos, presentan ventajas frente a los sistemas geotérmicos cerrados verticales, por tener costos iniciales que generalmente suelen ser menores. En España no existe ninguna Ley de Geotermia que regularice el uso del recurso geotérmico otorgando concesiones de exploración y explotación. La regulación en el caso de utilizar aguas subterráneas la tenemos en el Consejo Regulador de Aguas.
28

[en] DEVELOPMENT OF AN AUTOMOTIVE AIR CONDITIONING SYSTEM FOR HEATING AND COOLING / [pt] DESENVOLVIMENTO DE SISTEMA CLIMATIZADOR AUTOMOTIVO PARA AQUECIMENTO E RESFRIAMENTO

SERGIO LIBANIO DE CAMPOS 25 May 2015 (has links)
[pt] Sistemas condicionadores de ar automotivos têm sido extensivamente estudados, buscando melhor eficiência de resfriamento e redução do consumo de combustível. O presente trabalho tem como objetivo o estudo de um sistema condicionador de ar automotivo operando nos modos de resfriamento e aquecimento, este último atendendo às necessidades de conforto em dias frios nos veículos elétricos, os quais não apresentam calor de rejeito do motor, como nos veículos convencionais. Para tal foi projetado e montado, no Laboratório de Refrigeração, Condicionamento de Ar e Criogenia da PUC-Rio, um aparato experimental composto por duas câmaras de temperatura e umidade controladas, uma simulando o compartimento de passageiros e a outra, o ambiente externo. Um típico sistema condicionador de ar automotivo, composto por componentes comercialmente disponíveis e utilizados nos veículos atuais, foi dotado de válvulas direcionais, permitindo a inversão do ciclo de compressão de vapor do modo de resfriamento para o modo de aquecimento, operando neste último como bomba de calor. Dados experimentais foram levantados sob operação em regime permanente e transiente (período de partida), com temperaturas entre – 5 graus Celcius e 45 graus Celcius. Para o modo de resfriamento, seguiu-se a norma SAE J2765 e, para o de aquecimento, na ausência de normas, foram cobertas as operações em modos de recirculação do ar da cabine e de renovação com ar externo, entre as temperaturas de -5 graus Celcius e 10 graus Celcius. Foi também realizada uma simulação numérica, validada pelos dados experimentais, utilizando as equações fundamentais da termodinâmica e transferência de calor. O sistema testado mostrou-se viável na aplicação em veículos elétricos, uma vez que nestes o calor de rejeito previsto (regeneração de frenagem e efeito Joule na eletrônica de potência) não é suficiente para o conforto térmico em dias frios. Demonstrou-se que a bomba de calor consome menos energia que resistências as elétricas atualmente utilizadas. / [en] Automotive air conditioning systems have been extensively studied, searching for better cooling efficiency and reduced fuel consumption. The present work aims to study a system of automotive air conditioner operating in cooling and heating modes, the latter satisfies the needs of comfort on cold days in electrical vehicles, which do not include waste heat from the engine as the conventional vehicles. To this was designed and assembled in the Refrigeration, Air Conditioning and Cryogenics Laboratory, in Puc-Rio, an experimental apparatus consists of two chambers with temperature and humidity controlled, one, simulating the passenger compartment and the other, the external environment. A typical automotive air conditioning system, composed of commercially available components used in current vehicles is provided with a directional valve, allowing the inversion of vapor compression cooling mode to the heating mode cycle, the latter operating as a heat pump.
29

O uso da bomba de infusão inteligente em pacientes hospitalizados

Batiston, Michele Cristina January 2018 (has links)
Orientador: Silvana Andrea Molina Lima / Resumo: O objetivo deste trabalho foi avaliar a evidência científica disponível sobre o uso das bombas de infusão inteligentes em pacientes hospitalizados. Foi realizado um estudo, de acordo com Diretrizes Metodológicas propostas pelo Ministério da Saúde para a elaboração de pareceres técnico-científicos (PTC). Foi realizada uma busca até 14 de novembro de 2017 nas bases de dados The Cochrane Library, EMBASE, PubMed, Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS) e de Avaliações de Tecnologias de Saúde (ATS), não houve restrição de idioma e ano de publicação do artigo. Os resultados das bases de dados foram agrupados e eliminados os estudos em duplicatas. Em seguida, aplicados os critérios de elegibilidade para os títulos e resumos, restando 51 estudos para leitura completa. Após leitura dos artigos na íntegra, foram selecionados 6 estudos, que incluíram revisão sistemática sem metanálise, três estudos observacionais sem comparador e dois estudos observacionais do tipo antes e depois. Os estudos não apresentaram dados conclusivos para redução do número de eventos ocorridos. Para a interceptação de erros/prevenção de erros, os estudos demonstraram que a bomba inteligente interceptou e impediu diversos erros como frequência, dose e programação erradas. Para os custos, o estudo de revisão sistemática sem metanálise inclui um estudo que apresentou redução de custos da Bomba de Infusão Inteligente pelos possíveis eventos adversos evitáveis. A recomendação é incerta,... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Title: Intelligent Infusion Pump versus Conventional Infusion Pump: Comparison of cost and safety. Recommendation for the use of technology: ( ) In favor of (X) Uncertain ( ) Against Brief justification for the recommendation: Studies with little scientific evidence, the costs with the materials, the need to qualify, the construction of a library, among other strategies. Population: Patients hospitalized Technology: Intelligent Infusion Pumps Comparator: Conventional Infusion Pumps Search and analysis of scientific evidence: A search was performed to 2017, November 14 in the databases The Cochrane Library, EMBASE, PubMed and Latin American, Caribbean Literature in Health Sciences (LILACS) and the Health Technology Assessment (ATS). There was no language restriction and year of publication of the article. The results of the databases were grouped and the duplicate studies were eliminated. Then, the eligibility criteria for titles and abstracts were applied, leaving 51 studies for complete reading. After reading the articles in full, 06 studies were selected. Summary of results of selected studies: Six studies were included: one systematic review without meta-analysis, three observational studies without comparator, and two before-after observational studies. The studies did not present conclusive data to reduce the number of events that occurred. For error interception / error prevention, studies have shown that the smart pump intercepted and prevented various errors such as f... (Complete abstract click electronic access below) / Mestre
30

Associação entre o uso de inibidores da bomba de prótons e deficiência de magnésio : um corte transversal

Ascoli, Bruna Maria January 2012 (has links)
Introdução: Os inibidores de bomba de prótons (IBP) são medicamentos muito usados e estão indicados no tratamento de doenças pépticas. São drogas consideradas seguras, com pouca incidência de efeitos adversos. Entretanto há relatos recentes de séries de caso associando uso de IBP e deficiência de magnésio. O magnésio é um cátion de grande importância em diversos processos bioquímicos e a sua homeostase é regulada pela absorção intestinal, metabolismo ósseo e excreção renal. Objetivos: Devido ao pouco conhecimento atual em relação à associação entre hipomagnesemia e o uso crônico de IBP, o objetivo deste trabalho foi determinar a prevalência deste distúrbio eletrolítico e seus fatores associados em pacientes internados em duas equipes de Medicina Interna do Hospital de Clínicas de Porto Alegre (HCPA). Métodos: O estudo consistiu em um corte-transversal. Amostras de sangue e urina foram coletadas no período da manhã, após pelo menos 4 horas de jejum. Dados, tais como, idade, sexo, uso de IBP, hora e indicação de uso de IBP, o uso de outras medicações, e co-morbidades foram obtidos dos prontuários médicos. Pacientes com diarréia ou vômito, uso crônico de álcool, diabetes mellitus descompensado foram excluídos. Pacientes com uso crônico de laxantes, diuréticos e outras drogas relacionadas com a deficiência de magnésio, tais como a anfotericina B, aminoglicosídeos, e ciclosporina, também foram excluídos.Resultados: De setembro de 2010 a Junho de 2011 cerca de 800 pacientes foram admitidos na ala de emergência da medicina interna. Destes, 635 pacientes tinham critérios de exclusão, 14 pacientes se recusaram a participar, então 151 pacientes foram incluídos no estudo. Todos os pacientes tinham níveis normais de magnésio no soro. Não houve diferença entre a média dos níveis séricos de magnésio homens e mulheres. Não houve correlação entre a idade, níveis séricos de fósforo e potássio, com níveis séricos de magnésio. Albumina, creatinina, e cálcio foram positivamente correlacionados com níveis séricos de magnésio. Após a regressão linear múltipla, apenas os níveis séricos de albumina e creatinina foram independentemente associados com níveis séricos de magnésio. Quando a fração excrecional de Mg (FEMg) foi calculada após a exclusão dos pacientes que tinham níveis de creatinina sérica maiores que 1.3mg/dl, a média FEMg foi maior em usuários do PPI quando comparado com os outros pacientes apesar de magnésio no soro significa níveis foram semelhantes entre os grupos. Conclusão: A prevalência de hipomagnesemia foi menor do que a observada anteriormente. Isto pode ser devido aos critérios de exclusão deste estudo, que retirou pacientes com comorbidades, ou uso de drogas, comumente associados a hipomagnesemia. Os dados deste estudo mostraram que a associação entre uso IBP e hipomagnesemia é incomum, podendo ser devido a defeitos congênitos no metabolismo de magnésio, que em situações normais podem ser superados pelo organismo, mas na presença do IBP se torna evidente. Os mecanismos através dos quais esse efeito ocorre permanecem obscuros. As limitações deste estudo incluem a falta de um instrumento para medir a adesão ao uso do IBP e o tamanho da amostra. Nenhum paciente apresentou níveis baixos de magnésio, sugerindo que, para permitir o cálculo da prevalência desse efeito adverso, faz-se necessária uma amostra maior. / Background: Proton pump inhibitors (PPIs) are widely used and are indicated in the treatment of peptic diseases. They are considered safe, with low incidence of adverse effects. However there are recent reports of case series involving the use of PPI and magnesium deficiency. Magnesium is a cation of great importance in many biochemical processes and its homeostasis is regulated by intestinal absorption, bone metabolism and renal excretion. Objectives: Due to the limited knowledge regarding the association between hypomagnesemia and chronic use of PPIs, the objective of this study was to determine the prevalence of electrolyte disturbances and associated factors among hospitalized patients in two teams of Internal Medicine, Hospital de Clinicas de Porto Alegre (HCPA). Methods: A cross-sectional study was designed. Blood and urine samples were collected in the morning, after at least 4 hours of fasting. Data such as age, sex, use of PPIs, time and indication for use of PPIs, the use of other medications, and comorbidities were obtained from medical records. Patients with diarrhea or vomiting, chronic alcohol use, uncompensated diabetes mellitus were excluded. Patients with chronic use of laxatives, diuretics and other drugs related to magnesium deficiency, such as amphotericin B, aminoglycosides, and cyclosporine, were also excluded.Resultados: From September 2010 to June 2011 about 800 patients were admitted to the emergency ward of internal medicine. Of these, 635 patients had exclusion criteria, 14 patients refused to participate, so 151 patients were included in the study. All patients had normal levels of serum magnesium. There was no difference between the mean serum magnesium levels of men and women. There was no correlation between age, serum phosphorus and potassium levels with serum magnesium levels. Albumin, creatinine, and calcium were positively correlated with serum magnesium. After multiple linear regression analysis, only serum albumin and creatinine were independently associated with serum magnesium. When the fractional excretion of Mg (FEMg) was calculated after exclusion of patients who had serum creatinine greater than 1.3mg/dl, mean FEMg was higher in the PPI users compared with the non-users, although mean serum magnesium levels were similar between groups. Conclusion: The prevalence of hypomagnesemia was lower than that observed previously. This may be due to the exclusion criteria of this study that withdrew patients with comorbidities, or use of drugs, often associated with hypomagnesemia. Data from this study showed that the association between PPI use and hypomagnesemia is uncommon and may be due to defects in the metabolism of magnesium, which in normal situations can be overcome by the body but in the presence of IBP becomes evident. The mechanisms by which this effect occurs remain unclear. Limitations of this study include the lack of an instrument to measure adherence to the use of PPI and the sample size. No patient had low levels of magnesium, suggesting that, to allow the calculation of the prevalence of this adverse effect, it is necessary a larger sample.

Page generated in 0.0494 seconds