• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 259
  • 15
  • 6
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 292
  • 154
  • 64
  • 61
  • 58
  • 42
  • 36
  • 35
  • 35
  • 35
  • 35
  • 32
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Estudo te?rico das propriedades eletr?nicas e termodin?micas de nanofitas quasiperi?dicas BCN

Pedreira, Danilo Oliveira 19 February 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-08-25T20:38:32Z No. of bitstreams: 1 DaniloOliveiraPedreira_TESE.pdf: 7943420 bytes, checksum: 3266c07efadf03619e0cc898cba272f8 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-08-25T23:57:40Z (GMT) No. of bitstreams: 1 DaniloOliveiraPedreira_TESE.pdf: 7943420 bytes, checksum: 3266c07efadf03619e0cc898cba272f8 (MD5) / Made available in DSpace on 2016-08-25T23:57:40Z (GMT). No. of bitstreams: 1 DaniloOliveiraPedreira_TESE.pdf: 7943420 bytes, checksum: 3266c07efadf03619e0cc898cba272f8 (MD5) Previous issue date: 2016-02-19 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Materiais em nanoescala compostos por ?tomos de boro, carbono e nitrog?nio apresentam propriedades ?nicas e podem ser ?teis no desenvolvimento de novas tecnologias. Nesta tese, investigamos algumas propriedades de nanofitas BCN com arranjo quasiperi?dico dado por uma sequ?ncia Fibonacci. Analisamos propriedades como: estabilidade estrutural, densidade eletr?nica de estados, calor espec?fico eletr?nico, estrutura de bandas e gap de energia. Realizamos c?lculos de primeiros princ?pios baseados na teoria do funcional da densidade implementado como no c?digo SIESTA. Os resultados mostraram que nanofitas com maior gera??o Fibonacci tendem a apresentar um valor fixo para a energia de forma??o. A densidade eletr?nica de estados foi utilizada para calcular o calor espec?fico. Encontramos um comportamento oscilat?rio do calor espec?fico eletr?nico, para o regime de baixas temperaturas. Analisamos a estrutura de bandas para determinar o gap de energia. O gap de energia apresenta oscila??es como fun??o do ?ndice n da gera??o Fibonacci. Nosso trabalho sugere que uma escolha apropriada dos blocos de constru??o da sequ?ncia quasiperi?dica do material pode levar a um controle do gap de energia para nanofitas quasiperi?dicas. / Nanoscale materials composed of boron, nitrogen, and carbon have unique properties and may be useful in new technologies. In this thesis, we investigate some properties of BCN nanoribbons constructed according to the Fibonacci quasiperiodic sequence. We analyze properties such as structural stability, electronic density of states, electronic specific heat, band structure, and energy band gap. We have performed first-principles calculations based on density functional theory implemented in the SIESTA code. The results showed that nanoribbons present a fixed value of the formation energy. The electronic density of states was used to calculate the specific heat. We found an oscillatory behavior of the electronic specific heat, in the low temperature regime. We analyze the electronic band structure to determine the energy band gap. The energy band gap oscillates as a function of the Fibonacci generation index n. Our work suggest that appropriate choice of the building block materials of the quasiperiodic sequence, may lead to a tuneable band gap of the quasiperiodic nanoribbons.
52

Relação microestrutura e propriedades de aços ao boro tratados termicamente

Suski, Cássio Aurélio January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Ciência e Engenharia de Materiais / Made available in DSpace on 2012-10-26T02:22:53Z (GMT). No. of bitstreams: 0Bitstream added on 2013-07-16T20:44:43Z : No. of bitstreams: 1 299907.pdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / A adição de baixos teores de boro nos aços baixo e médio carbono apresenta a característica de aumentar a temperabilidade por atuar na redução da energia livre nos contornos de grão austenítico devido à segregação de átomos de boro nos contornos, reduzindo a formação de ferrita pró-eutetóide. A composição química, a temperatura de austenitização, temperatura de revenido e a velocidade de resfriamento influenciam consideravelmente no efeito do boro no aumento da temperabilidade. O tratamento térmico de têmpera de componentes fabricados em aço ao boro possui alguns fatores que influenciam na escolha das temperaturas de austenitização. Dentre estes fatores há a necessidade de se obter a microestrutura martensítica através de temperaturas que minimizem a degradação do forno de tratamento térmico. Os objetivos desta tese foram estudar o efeito da temperatura de austenitização na precipitação de carbonetos/borocarbonetos e nas propriedades mecânicas dos aços ao boro PL22 e 15BCr30 após têmpera e revenido e a correlação entre as microestruturas obtidas, propriedades mecânicas e temperabilidade. Para avaliar o efeito da temperatura de austenitização e a solubilização do boro foram utilizadas três temperaturas, uma a comumente utilizada na indústria (870ºC - pouco acima da linha Ac3), uma temperatura um pouco acima da temperatura usual (1050ºC) e outra bastante acima (1200ºC). Observou-se inicialmente que o tamanho de grão austenítico aumenta com a temperatura de austenitização após têmpera e revenido. As análises de microestrutura mostraram que a maior porcentagem de martensita foi obtida com a temperatura de austenitização de 1050ºC, devido à redução da energia livre nos contornos de grão austenítico que reduz a nucleação de ferrita. Na temperatura de austenitização de 870ºC a menor quantidade de martensita foi atribuída à baixa porcentagem de boro em solução e a 1200ºC à maior segregação de não-equilíbrio de boro nos contornos de grão, indicada pela precipitação de borocarbonetos. Nas análises realizadas por microscopia eletrônica de transmissão foi observado a presença de borocarbonetos Fe23(C,B)6 em todas as condições de austenitização, tanto na matriz, quanto nos contornos de grão, porém uma menor quantidade para a austenitização à 1050ºC, proporcionando um melhor efeito do boro no aumento da temperabilidade para esta condição. Finalmente, foram comparados os resultados das propriedades mecânicas com a microestrutura encontrada nos dois aços ao boro. Os resultados mostraram boa concordância entre os valores obtidos nos ensaios e as porcentagens de martensita e a presença de borocarbonetos. Os limites de escoamento e resistência obtidos a partir da austenitização a 1050ºC apresentaram os maiores valores devido ao maior percentual de martensita que está relacionado à menor segregação total de boro nesta condição.
53

Desenvolvimento de metodologia eletroanalítica para a determinação de sulfonamidas empregando eletrodo de diamente dopado com boro

Silveira, Cristine Durante de Souza January 2008 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-graduação em Química / Made available in DSpace on 2012-10-24T03:23:35Z (GMT). No. of bitstreams: 1 249542.pdf: 737178 bytes, checksum: 271e6588074b30cc46cc57ede6806e31 (MD5) / A sulfadiazina e a sulfametoxazol foram eletroanaliticamente quantificadas utilizando a voltametria de onda quadrada (VOQ) com o eletrodo de diamante dopado com boro (BDD). A determinação eletroanalítica da sulfadiazina foi feita em etanol/H2SO4 0,5 mol L-1 50/50 v/v, e a determinação da sulfametoxazol foi feita em etanol/tampão fosfato 0,05 mol L-1 50/50 v/v em pH 5,7. As sulfas apresentaram somente um pico de oxidação em aproximadamente +1,1 V/ECS com características irreversíveis, o qual foi utilizado como resposta analítica. A curva analítica foi obtida no intervalo de concentração de 2,91x10-5 a 9,09x10-5 mol L-1 (r = 0,9995) para a sulfadiazina e de 9,90x10-5 a 6,54x10-4 mol L-1 (r = 0,9954) em etanol/H2SO4 0,5 mol L-1 e 1,48x10-5 a 6,67x10-5 mol L-1 (r = 0,9967) em etanol/tampão fosfato 0,05 mol L-1 para a sulfametoxazol. O limite de detecção foi 2,51x10-6 mol L-1 para a sulfadiazina e 2,95x10-5 e 2,52x10-7 mol L-1 para a sulfametoxazol. Soluções padrão dos compostos estudados foram adicionadas em soluções preparadas de produtos farmacêuticos. A recuperação variou de 95 a 104% para ambas sulfonamidas, indicando a não interferência da matriz sobre os resultados analíticos. A exatidão da metodologia eletroanalítica desenvolvida foi também comparada com o método oficial (HPLC). O erro relativo percentual entre o método oficial e o método proposto foi de -4,31% para a sulfadiazina e +0,79% para a sulfametoxazol. Os dados sugerem que o método desenvolvido pode ser usado alternativamente ao método oficial para determinação eletroanalítica de sulfas em formulações farmacêuticas e outros produtos. Sulfadiazine and sulfamethoxazole were electroanalytically quantified by square-wave voltammetry (SWV) at a boron-doped diamond (BDD) electrode. The determination of sulfadiazine was obtained in an ethanol/0.5 mol L-1 H2SO4 50/50 (v/v) solution and sulfamethoxazole in an ethanol/pH 5.7 phosphate buffer 50/50 (v/v) solution. Both sulfonamides showed a well-resolved irreversible oxidation peak at around +1.1 V/SCE, which was used as analytical response. Excellent calibration curves were obtained in the concentration ranges of 2.91x10-5 to 9.09x10-5 mol L-1 (r = 0.9995) for sulfadiazine and 9.90x10-5 to 6.54x10-4 mol L-1 (r = 0.9954) in an ethanol/0.5 mol L-1 H2SO4 and 1.48x10-5 a 6.67x10-5 mol L-1 (r = 0.9967) in an ethanol/pH 5.7 phosphate buffer for sulfamethoxazole. Detection limits of 2.51x10-6 mol L-1 were found for sulfadiazine and 2.95x10-5 and 2.52x10-7 mol L-1 were found for sulfamethoxazole. Standard solutions of studied compounds were spiked in real samples prepared from tablets of commercial pharmaceutical products. The recovery varied from 95 to 104% for both sulfonamides in all analyzed real samples, indicating no interferences of matrixes on the analytical results. The accuracy of the developed electroanalytical methodology was also compared to HPLC official method. Percent relative error between the official and proposed methods was -4.31% for sulfadiazine and +0.79% for sulfamethoxazole. The data suggest a potential and interesting alternative method for electroanalytical determination of sulfa drugs in pharmaceutical and other products.
54

[en] BORON REMOVAL FROM OIL PRODUCTION WASTEWATER AND EFFLUENTS BY ADSORPTION / [pt] REMOÇÃO DE BORO DE ÁGUAS E EFLUENTES DE PETRÓLEO POR ADSORÇÃO

JAVIER PAUL MONTALVO ANDIA 18 November 2009 (has links)
[pt] A presença de boro nas águas em geral tem se incrementado de forma contínua e paralela ao desenvolvimento industrial. Da mesma forma, os efeitos prejudiciais aos organismos vivos tem aumentado, especialmente sobre as plantas onde a faixa entre a deficiência e a toxicidade é muito curta. No presente trabalho foi investigado o efeito das diferentes variáveis de operação, na cinética e na termodinâmica de um processo de adsorção de boro com MgO a partir de águas e efluentes gerados na produção de petróleo. Os resultados obtidos mostram que o processo de adsorção é viável, e alcança eficiências em torno de 80% (em pH = 10; concentração de MgO-500 = 40 g.L(-1) (área superficial = 1259 m2), temperatura = 25oC, agitação =150 rpm e tempo = 60 min.). O processo é fortemente influenciado pelo pH, e também pela área superficial (tamanho de partícula) do adsorvente, concentração inicial do boro, salinidade da solução, e pela a presença de outros íons na solução. A temperatura também tem um efeito positivo no processo. A remoção de boro com MgO foi quantitativamente avaliada usando isotermas de adsorção.. Verificou-se que o processo se ajusta melhor à isoterma de Freundlich. A constante da isoterma de Freundlich, Kad (mg.g(-1)) = 0,57 foi maior em comparação a outras Kad obtidas na adsorção de boro com outros adsorventes. Finalmente, os parâmetros cinéticos e termodinâmicos do processo calculados indicam que o processo acontece de forma espontânea e é cineticamente bem representado por um modelo de pseudo segunda ordem. / [en] The presence of boron in waters has increased continually and in parallel to the industrial development. And also, the harmful effects to the organisms and living creatures has increased as well, especially on plants, where the gap between the deficiency and the toxicity is very short. In the present work it was investigated the effects of different operating variables in, the kinetics and in the thermodynamics of a process of boron adsorption with MgO from wastewaters generated in the production of oil. The results show that the adsorption process is feasible, and reaches efficiencies around 80%, in the following conditions: pH = 10; MgO-500 concentration = 40 g.L(-1) (surface area: 1259 m2); temperature: = 25oC; stirring = 150 rpm and time = 60 min. The process is strongly influenced by pH, and also by the superficial adsorbent area (particle size), initial concentration of boron, salinity of the solution, and the presence of others ions in the solution. The temperature also has a positive effect in the process. The removal of boron with MgO was evaluated quantitatively using adsorption isotherms. It was shown that the process is better adjusted by the Freundlich isotherm. The constant of the Freundlich isotherm, Kad (mg.g(-1)) = 0,57 was bigger in comparison to other Kad gotten in the adsorption of boron with other adsorbents. Finally, the kinetic and thermodynamic parameters of the process indicate that the process is spontaneous, and is kinetically well represented by a pseudo second-order model.
55

Sinterização de carbeto de boro com alta resistência ao desgaste

Turatti, Águeda Maria January 2009 (has links)
O carbeto de boro (B4C) é um material cerâmico de alta dureza e baixa massa específica com uma grande potencialidade de aplicação tecnológica. Contudo, há uma grande dificuldade na produção de sinterizados com alta massa específica e boas propriedades mecânicas pelo uso de técnicas convencionais de sinterização. Neste trabalho, foi investigada a influência de vários parâmetros (granulometria do pó de partida, adição de carbono e ligantes orgânicos, temperatura máxima e taxa de aquecimento) na sinterização do carbeto de boro. Foram utilizadas técnicas de sinterização à pressão ambiente e de sinterização sob pressões ultra-elevadas. Amostras cilíndricas, com 15 mm de diâmetro e entre 3 e 7 mm de espessura, foram sinterizadas à pressão ambiente em atmosfera de Argônio a 2150ºC, 2200ºC e 2250ºC por 120 minutos, com taxas de aquecimento de 25 e de 30ºC/min. Amostras de 3 mm de diâmetro e 2,5 mm de espessura foram processadas a 4 GPa durante 10 minutos em diferentes temperaturas de sinterização (1000°C, 1500ºC e 1700°C). O principal objetivo tecnológico do trabalho foi desenvolver e otimizar uma sistemática de conformação e sinterização para a produção de peças de carbeto de boro, com diferentes geometrias, e alta dureza e alta resistência ao desgaste. A composição de fases e a microestrutura dos compactos foram investigadas por difração de raios X, espectroscopia Raman, microscopia óptica e microscopia eletrônica de varredura. As propriedades mecânicas foram avaliadas por medidas de massa específica, dureza Vickers e resistência ao desgaste abrasivo. Os resultados de massa específica obtidos para os sinterizados à pressão ambiente a partir de um pó mais grosso (< 3 mm) foram, de forma não usual, superiores aos encontrados para os produzidos com um pó mais fino (< 1 mm), obtendo-se valores máximos de 2,42 g/cm3 para o pó grosso e 2,33 g/cm3 para o pó fino. As medidas de dureza resultaram valores máximos de 21 GPa, tanto para o pó mais fino quanto para o pó mais grosso, no caso de sinterizados produzidos a partir de uma mistura com ligantes. Quando não foram usados ligantes, no caso do pó mais grosso, valores de resistência ao desgaste abrasivo muito próximos ao de uma peça comercial e uma dureza de 27 GPa, foram obtidos por sinterização à pressão ambiente. A produção de compactos bem densificados e com propriedades mecânicas superiores foi associada à remoção efetiva de fases óxidas do pó de partida. A presença dessas fases influencia fortemente a cinética de crescimento de grãos durante a sinterização do carbeto de boro. Os compactos produzidos sob pressões ultra-elevadas apresentaram valores máximos de dureza de 15 GPa para o pó mais grosso e 20 GPa para o pó mais fino. Esses resultados obtidos abrem perspectivas bastante interessantes de utilização da técnica de pressões ultra-elevadas na sinterização de carbeto de boro, com a aplicação de temperaturas e tempos bem menores do que os empregados convencionalmente. / Boron carbide (B4C) is a high hardness, low-density ceramic material with a great potential for technological application. However, the production of sintered bodies with high densification and good mechanical properties is very difficult when conventional sintering techniques are used. In this study, we investigated the influence of different sintering conditions (size of the carbide powder, addition of carbon and organic binders, maximum temperature and heating rate) on the properties of boron carbide sintered at ambient pressure or under ultra-high pressure. Cylindrical samples, 15 mm in diameter and 3 to 7 mm thick, were sintered at ambient pressure in an argon atmosphere and temperatures of 2150°C, 2200°C and 2250°C for 120 minutes, using heating rates of 25 and 30°C/min. Samples of 3 mm in diameter and 2.5 mm in thickness were processed at 4 GPa and different sintering temperatures (1000°C, 1500°C and 1700°C) for 10 minutes. The main technological goal of this study was the development of a sintering procedure to produce different geometries of boron carbide compacts with high hardness and high wear resistance. The phase composition and the microstructure of the samples were investigated by x-ray diffraction, Raman spectroscopy, optical microscopy and scanning electron microscopy. The sintered bodies were characterized by density, hardness and abrasive wear resistance measurements. In an unusual way, the density values obtained for the compacts sintered at ambient pressure from a coarser powder (< 3 mm) were higher than those found for the compacts produced from a finer powder (< 1 mm). The highest density values were 2.42 g/cm3 for the coarse powder and 2.33 g/cm3 for the fine powder. The maximum obtained hardness for the sintered bodies produced from a mixture with organic binders was 21 GPa, both for the fine and the coarse powder. When no binders were used, a hardness of 27 GPa associated to a high wear resistance was obtained for compacts sintered at ambient pressure using the coarse powder. The success in the production of high-density compacts with superior mechanical properties was associated to an efficient removal of oxides phases from the starting powder. The presence of these phases strongly affects the grain growth kinetics during the sintering of boron carbide. The compacts produced under ultra-high pressures showed a maximum hardness of 15 GPa for the coarse powder and 20 GPa for the fine powder. The obtained results indicate that the employment of ultra-high pressure techniques can be very interesting for the production of high-quality sintered boron carbide, as they enable the use of much lower temperatures and shorter sintering times than in conventional techniques.
56

Desenvolvimento de metodologia eletroanalítica para determinação de dipirona em amostras de medicamentos, de aguas naturais e de urina humana. / Development of eletroanalytic methodology for determination of dipirone in samples of medicines, natural waters and human urine.

Gomes, Rayane Nunes January 2017 (has links)
GOMES, Rayane Nunes. Desenvolvimento de metodologia eletroanalítica para determinação de dipirona em amostras de medicamentos, de águas naturais e de urina humana. 2017. 79 f. Dissertação (Mestrado em Química)-Universidade Federal do Ceará, Fortaleza, 2017. / Submitted by Anderson Silva Pereira (anderson.pereiraaa@gmail.com) on 2017-03-22T17:44:57Z No. of bitstreams: 1 2017_dis_rngomes.pdf: 1528322 bytes, checksum: 90dc687ae811894f269f57cdac9dd862 (MD5) / Approved for entry into archive by Jairo Viana (jairo@ufc.br) on 2017-03-23T18:21:31Z (GMT) No. of bitstreams: 1 2017_dis_rngomes.pdf: 1528322 bytes, checksum: 90dc687ae811894f269f57cdac9dd862 (MD5) / Made available in DSpace on 2017-03-23T18:21:31Z (GMT). No. of bitstreams: 1 2017_dis_rngomes.pdf: 1528322 bytes, checksum: 90dc687ae811894f269f57cdac9dd862 (MD5) Previous issue date: 2017 / The present work describes the development of an electroanalytical methodology using boron doped diamond electrode (BDDE) associated to the square wave voltammetry (SWV) technique for the determination of dipyrone (DIP) in commercial formulations, waters of the Gavião dam, Acarape of the Meio and in human urine. By means of the cyclic voltammetric (CV) technique, it was verified that the oxidation of the DIP on the surface of the BDDE presents irreversible behavior, diffusional control, as well as a reaction mechanism with the participation of protons. Both CV and SWV were calculated, respectively, 0.19 and 0.11 as values for the load transfer coefficient. Once the optimized reaction conditions were established, which were BR buffer pH 7.0 as support electrolyte and the parameters f = 100 s−1, a = 25 mV and ΔEs = 2 mV, analytical curves were constructed, determined as region linear regression analysis of 1.0 × 10−6 to 6.5 × 10−5 mol L−1 and the limits of detection (LD) and quantification (LQ) values were respectively 2.64 × 10−7 and 8.80 × 10−7 mol L−1. Regarding the repeatability and reproducibility tests, the results in terms of relative standard deviations (RSD) were below 2.5%. Aiming to evaluate the applicability of the proposed methodology, studies of recovery of DIP present in the drug in the form of an oral solution in a buffer of BR pH 7.0 were carried out, as well as were carried out in this electrolyte prepared with waters of the Gavião dam, Acarape of the Meio and in electrolyte containing human urine. The mean recovery percentage, followed by the respective DPR value obtained for the recovery studies involving DIP oral solution in buffer pH 7.0, waters of the Gavião dam, Acarape of the Meio and human urine were, Respectively, 108.33 % (DPR 2.67 %); 117.33 % (DPR 2.15 %); 91.00 % (DPR 1.98 %) and 104.00 (DPR 1.92 %). The results of the recovery trials using iodometric titration by means of the methodology proposed by the brazilian pharmacopoeia, with some adaptations, being analyzed DIP oral solution, waters of the Gavião dam, Acarape of the Meio and human urine were, respectively, 100.10 % (DPR 2.86 %); 106.86 % (DPR 2.41 %); 93.34 % (DPR 1.77%) and 104.57 % (DPR 0.76 %). These results, when compared statistically with the results obtained using the VOQ technique, indicated, according to Student's t test, that there was no significant difference between the mean recovery percentage faced, which proved the efficiency of the electroanalytical methodology developed in this work for The determination of DIP in the matrices tested. / O presente trabalho descreve o desenvolvimento de uma metodologia eletroanalítica utilizando eletrodo de diamante dopado com boro (EDDB) associado à técnica de voltametria de onda quadrada (VOQ) para determinação de dipirona (DIP) em formulações comerciais, águas do açude Gavião, águas do açude Acarape do Meio e em urina humana. Por meio dos estudos utilizando a técnica de voltametria cíclica (VC), foi verificado que a oxidação da DIP na superfície do EDDB apresenta comportamento irreversível, controle difusional, assim como, mecanismo reacional com a participação de prótons. Tanto por VC quanto por VOQ foi calculado, respectivamente, 0,19 e 0,11 como valores para o coeficiente de transferência de carga. Depois de estabelecidas as condições experimentais otimizadas, que foram tampão BR pH 7,0 como eletrólito de suporte e os parâmetros f = 100 s−1, a = 25 mV e ΔEs = 2 mV, construiu-se curvas analíticas obtendo região linear de 1,0 × 10−6 a 6,5 × 10−5 mol L−1 e os valores dos limites de detecção (LD) e de quantificação (LQ) foram respectivamente iguais a 2,64 × 10–7 e 8,80 × 10−7 mol L−1. Quanto aos ensaios de repetibilidade e reprodutibilidade, os resultados em termos de desvio padrão relativo (DPR) apresentaram-se abaixo de 2,5 %. Visando avaliar a aplicabilidade da metodologia proposta foram realizados estudos de recuperação de DIP presente no medicamento na forma de solução oral em meio de tampão BR pH 7,0, assim como foram realizados em meio deste eletrólito preparado com águas do açude Gavião e do Açude Acarape do Meio e em eletrólito contendo urina humana. A taxa média de recuperação, seguido do seu respectivo valor de DPR, obtido para os estudos de recuperação envolvendo solução oral DIP em meio de tampão BR pH 7,0, águas dos açudes Gavião, águas do açude Acarape do Meio e urina humana foram, respectivamente, 108,33 % (DPR 2,67 %); 117,33 % (DPR 2,15 %); 91,00 % (DPR 1,98 %) e 104,00 (DPR 1,92 %). Os resultados dos ensaios de recuperação utilizando titulação iodométrica por meio da metodologia proposta pela Farmacopeia Brasileira, com algumas adaptações, sendo analisada solução oral DIP, águas dos açudes Gavião, águas do açude Acarape do Meio e urina humana foram, respectivamente, 100,10 % (DPR 2,86 %); 106,86 % (DPR 2,41 %); 93,34 % (DPR 1,77 %) e 104,57 % (DPR 0,76 %). Esses resultados, quando comparados estatisticamente com os resultados alcançados utilizando a técnica de VOQ, indicaram, segundo o teste t de Student, que não existia diferença significativa entre as taxas médias de recuperação confrontadas, o que comprovava a eficiência da metodologia eletroanalítica desenvolvida neste trabalho para a determinação de DIP nas matrizes testadas.
57

Comportamento de cultivares de algodão em resposta a doses de boro no solo / Cotton cultivars behaviour in answer to boron dosages on soil

Medeiros, Joaci Franklin de 26 February 2003 (has links)
Submitted by Nathália Faria da Silva (nathaliafsilva.ufv@gmail.com) on 2017-06-22T13:14:25Z No. of bitstreams: 1 texto completo.pdf: 400349 bytes, checksum: 0f885d0e3e8f396e57fd90379f9b8634 (MD5) / Made available in DSpace on 2017-06-22T13:14:25Z (GMT). No. of bitstreams: 1 texto completo.pdf: 400349 bytes, checksum: 0f885d0e3e8f396e57fd90379f9b8634 (MD5) Previous issue date: 2003-02-26 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / O conhecimento do comportamento das cultivares de algodoeiro quanto à tolerância à falta ou ao excesso de boro é relevante para orientar recomendações de corretivos e fertilizantes, escolha de cultivares e programas de melhoramento genético. Assim, o objetivo deste trabalho foi avaliar o comportamento de cultivares de algodoeiro herbáceo (Gossypium hirsutum L.) em resposta a doses de boro no solo. O experimento foi conduzido na Embrapa Algodão sob condições de casa de vegetação. Adotou-se o delineamento inteiramente casualizado, com os tratamentos arranjados em esquema fatorial 6 x 5, correspondendo a 6 doses de boro (0,0; 0,5; 1,0; 1,5; 2,0; e 3,0 mg dm -3 ) e 5 cultivares de algodoeiro herbáceo (CNPA 8H, BRS Aroeira, BRS Antares, BRS Sucupira e BRS Ipê), com 3 repetições. Utilizaram-se 90 vasos de plástico com 7 dm 3 de solo cada. No dia do plantio, o solo recebeu as doses de boro na forma de H 3 BO 3 , aplicadas em solução. Adicionalmente, realizou-se a adubação básica comum a todos os tratamentos. De modo geral, as doses de boro utilizadas não influenciaram as variáveis estudadas para as condições do experimento, com exceção dos teores de boro no limbo foliar. A capacidade de utilização de boro pelas cultivares de algodoeiro apresentou a seguinte ordem: BRS Aroeira > CNPA 8H e BRS Antares > BRS Ipê e BRS Sucupira. A concentração de boro no limbo foliar aumentou linearmente para as cultivares CNPA 8H e BRS Aroeira, enquanto, que para as cultivares BRS Ipê e BRS Sucupira esse aumento foi de forma quadrático. Para a cultivar BRS Ipê o ponto de máximo para teor de boro foliar com seu respectivo valor para a dose de B adicionada foi de 48,0 mg kg -1 de B e 2,5 mg dm -3 , enquanto, que para a cultivar BRS Sucupira foi de 45,7 mg kg -1 de B e 1,5 mg dm -3 . Sintomas de deficiência de B foram observados nos tratamentos em que não se utilizou este micronutriente na adubação independente da cultivar estudada. Para as doses de B utilizadas não foram observados nas cultivares de algodão estudadas sintomas de fitotoxidade. / The knowledgement of cotton cultivars’ behaviour with respect to the tolerancy to lack or excess of boron is relevant to orient fertilizers and correctives recommendations, choose of cultivars and breeding. Then, the aim of this work was to evaluate the behaviour of upland cotton (Gossypium hirsutum L.) cultivars in answer to different boron dosages on the soil. This work was developed at Embrapa Algodão under greenhouse conditions. The experimental design adopted was completely randomized with treatments arranged in a 6 x 5 factorial, i.e., 6 boron levels (0.0, 0.5, 1.0, 1.5, 2.0, and 3.0 mg dm -3 ) applied as solution boric acid, and 5 cotton cultivars (CNPA 8H, BRS Aroeira, BRS Antares, BRS Sucupira and BRS Ipê), with 3 replications. Ninety plastic containers with 7 dm 3 of soil were used. In general, the boron dosages used did not present difference at the studied variables into the experiment conditions, excepting to the leaf boron levels. The boron usage capability by the cotton cultivars were as follows: BRS Aroeira > CNPA 8H and BRS Antares > BRS Ipê and BRS Sucupira. Leaf boron level increased linearly in cultivars CNPA 8H and BRS Aroeira while for cultivars BRS Ipê and BRS Sucupira the effect was quadratic. To BRS Ipê cultivar, the highest boron level and its respective dosage added to the soil were 48,0 mg kg -1 and 2,5 mg dm -3 respectively, while BRS Sucupira values were 45,7 mg kg -1 and 1,5 mg dm -3 . Symptoms of boron deficiency were observed in treatments which did not receive the nutrient, independent of the cultivar. Were not observed toxity by the cotton plants studied using the boron dosages of this work.
58

Otimização multivariada e validação de métodos para a determinação de boro, enxofre, fósforo e molibdênio em fertilizante mineral por ICP OES

Oliveira, Tiago Charão de January 2016 (has links)
Neste trabalho foram desenvolvidos e validados métodos de determinação de boro, enxofre, fósforo e molibdênio em fertilizante mineral e enxofre elementar em formulação comercial, por ICP OES. As condições de preparação das amostras foram otimizadas mediante metodologia multivariada, utilizando-se matriz Doehlert. A decomposição da amostra em sistema fechado, com o auxílio de radiação micro-ondas, mostrou-se necessária somente para a determinação de enxofre na formulação comercial. As condições consideradas ótimas, pela mesma abordagem multivariada, para a potência do plasma, pressão do gás de nebulização e vazão da solução da amostra nas determinações por ICP OES foram 1,50 kW, 180 kPa e 2,4 mL min-1, respectivamente. O método mostrou-se seletivo, exceto para a interferência do cobre no sinal do fósforo (213,618 nm) e do citrato neutro de amônio (CNA) para todos os elementos. Foram obtidas curvas analíticas com boa linearidade, normalidade, homocedasticidade dos resíduos e inexistência de auto correlação. Os limites de quantificação teóricos, segundo os métodos propostos são: 0,042% (m/m) de enxofre (extraído mediante aquecimento por radiação microondas em frasco fechado); 0,030% (m/m) de boro (extração em frasco aberto e aquecimento sob ebulição em chapa metálica); 0,010 % (m/m) de fósforo (extração com CNA + H2O), medido em 213,618 nm; 0,118 % (m/m) de fósforo (extração com CNA + H2O), medido em 213,547 nm; 0,0050% (m/m) de molibdênio (extração em frasco aberto e aquecimento sob ebulição em chapa metálica). As incertezas relativas estimadas segundo a metodologia Bottom-Up foram: 7,1% para o boro; 4,3% para o enxofre; 7,6% para o molibdênio; 7,4% para o fósforo medido em 213,618 nm e 7,8% quando medido em 213,547 nm. Os principais fatores de incerteza identificados foram: precisão intermediária, recuperação do analito, regressão linear da curva analítica e a incerteza herdada do volume medido/liberado pelos aparelhos volumétricos utilizados (vidrarias e micropipetas). Foram obtidos resultados satisfatórios nas análises de materiais de referência, amostras analisadas em programas interlaboratoriais e nos testes de recuperação do enxofre, demonstrando a adequação dos métodos propostos para o uso em rotina. / This study deals with the development and validation of methods for boron, sulfur, phosphorus and molybdenum determination in mineral fertilizer and elemental sulfur in commercial formulation by inductively coupled plasma optical emission spectrometry (ICP OES). The sample preparation conditions/procedures were optimized by a multivariate approach, using a Doehlert matrix. The plasma power, nebulizer gas pressure and peristaltic pump speed used in ICP OES determinations were 1.50 kW, 180 kPa and 24 rpm (2.4 mL min-1) respectively, which were optimized following the same multivariate approach (using a Doehlert matrix). For sulfur determination in commercial formulation of sulfur, the sample decomposition needed to be carried out in closed flask and assisted by microwave radiation. The methods proved to be interference-free, excepting spectral interference of copper on phosphorus 213.618 nm and non-spectral interference by neutral ammonium citrate (NAC) on all investigated elements. Calibration curves with good linearity, normality, homoscedasticity of residues and without autocorrelation were obtained. The theoretical limits of quantification of the developed and validated methods are: 0.042% (m/m) of sulfur (extracted in closed flask in microwave oven); 0.030% (m/m) of boron (extraction in open flask and heating on hot plate); 0.010% (m/m) of phosphorus (extraction by NAC + H2O), measured in 213.618 nm; 0.118% (m/m) of phosphorus (extraction by NAC + H2O), measured in 213.547 nm and 0.0050% (m/m) of molybdenum (extraction in open flask and heating on hot plate). The uncertainties of the methods estimated by the Bottom-Up approach were: 7.1% for boron; 4.3% for sulfur; 7.6% for molybdenum; 7.4% for phosphorus 213.618 nm and 7.8% for phosphorus 213.547 nm. The main factors of uncertainty identified were: intermediate precision, analyte recovery, linear regression for calibration curve and the inherited uncertainty of the measured/released volume by volumetric devices used (laboratory glassware and micropipettes). Satisfactory results were found in the analysis of certified reference materials, samples analyzed in inter-laboratory comparison programs and sulfur recovery in spiked sample of commercial formulation of sulfur. These results obtained demonstrated that the proposed methods are suitable for routine analysis of mineral fertilizer and commercial sulfur formulation.
59

Proposta de uma rotina de análise usando o eletrodo de diamante dopado com boro para determinação simultânea de metais traço em água de coco

ROSA, T. R. 31 August 2015 (has links)
Made available in DSpace on 2016-08-29T15:35:40Z (GMT). No. of bitstreams: 1 tese_9156_Thalles Ramon Rosa.pdf: 4051801 bytes, checksum: 19de1ca952cfa21664f9d23e6384c604 (MD5) Previous issue date: 2015-08-31 / A combinação da voltametria de redissolução anódica usando onda quadrada (SWASV) com o eletrodo de diamante dopado com boro (DDB) foi proposta para a determinação simultânea de Zn, Cd, Pb e Cu livre e total em água de coco natural e industrializada. Os valores ótimos e/ou escolhidos a partir do planejamento experimental para essa técnica foram: -1500 mV e 240 s para o potencial e tempo de pré-concentração; 0,206 mol L^(-1) para a concentração do tampão acetato pH 4,7; 11,56 mV para o incremento do potencial; 55 mV e 100 Hz para a amplitude de pulso e frequência. A aplicação da SWASV na amostra industrializada de água de coco I (IA), sem digestão prévia, forneceu concentrações livres de Zn e Cu iguais a 76,8±4,2 e 7,7±0,6 &#956;g L^(-1), respectivamente. Comparando com a técnica ICP OES, essas concentrações foram 0,33 (230±2 &#956;g L^(-1)) de Zn e 1,54 (5,0±0,5 &#956;g L^(-1)) do Cu. Nesta determinação, as concentrações de Cd e Pb foram menores que os respectivos &#12310;LD&#12311;_(ICP OES), 0,25 e 1,6 &#956;g L^(-1). Por outro lado, uma determinação da concentração total desses analitos foi obtida após uma digestão assistida por ultrassom. Neste método, foram usados 1,00 mL da amostra de água de coco natural A, 0,8 mL de H2O2 (37%, v/v) e 0,6 mL HCl (35%, v/v). Após aplicação da SWASV na amostra digerida, os valores de concentração para Zn e Cu foram 1,02 e 0,46 em relação aos valores obtidos por ICP OES. Novamente, Cd e Pb foram menores que o LD de ambas as técnicas. Alternativamente, foram realizados estudos preliminares aplicando a SWASV, com as mesmas variáveis citadas anteriormente, porém empregando o tampão amoniacal pH 8,0 em substituição ao tampão acetato pH 4,7, para determinar a concentração dos quatro metais em uma amostra natural E (NE) digerida. Os resultados obtidos para Zn e Cu foram, respectivamente, 192,6±17 (1,04 do ICP OES) e 13±3 &#956;g L^(-1) (<1,6 &#956;g L^(-1), &#12310;LD&#12311;_(ICP OES)), com destaque para a grande sensibilidade obtida para o Cu. Ao final desses estudos, podemos constatar que o uso do eletrodo de diamante dopado com boro em conjunto com a SWASV é uma ferramenta analítica sensível e versátil, que abre novas possibilidades para a determinação de metais traço em amostras naturais e digeridas.
60

Análise e monitoramento da retificação do ferro fundido nodular com rebolos de nitreto de boro cúbico (CBN)

Taborga, Jeshael Denis Morales January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica. / Made available in DSpace on 2012-10-20T00:07:41Z (GMT). No. of bitstreams: 0 / Neste trabalho se apresenta a análise e monitoramento da retificação do ferro fundido nodular utilizando rebolos CBN com ligante de resina mediante a retificação cilíndrica de mergulho. Para monitorar o processo preparou-se uma bancada de ensaios composta por sensores de medição de corrente por efeito Hall e um sensor de emissão acústica (E.A) rotacional sem contato, interligados a um computador mediante uma placa de aquisição de dados e seu respetivo software de aquisição e armazenamento. Para analisar o processo, são utilizadas grandezas como: desgaste, rugosidade, sinais de corrente, sinais de emissão acústica, variando-se os parâmetros de entrada na retificação. Os sinais de corrente e emissão acústica são analisados mediante um software de tratamento de sinais desenvolvido em LabViewÒ. Para o perfilamento do rebolo é utilizado um rolo dressador, e para a afiação, blocos de oxido de alumínio (Al2O3) que são acionados por um dispositivo hidro-pneúmatico. Este dispositivo é equipado com um sistema pinhão-cremalheira, um encoder rotacional e um tacômetro que permitem determinar a velocidade de avanço e a profundidade consumida do bloco de Al2O3. Este sistema é também ligado à bancada de ensaios, permitindo monitorar sinais de corrente e E.A durante a afiação e conhecer o volume necessário que deve ser consumido do bloco de Al2O3 para afiar o rebolo. No trabalho, comprovou-se que o monitoramento, o tratamento e análise dos sinais junto com grandezas obtidas como o desgaste e rugosidade são ferramentas úteis para analisar o processo de retificação.

Page generated in 0.143 seconds