Spelling suggestions: "subject:"bracket""
171 |
Une évaluation de la dimension de la lumière de boîtiers 0,018″ provenant de quatre différents manufacturiers. Existe-t-il un standard dans l’industrie?Richard, Laurent A. 04 1900 (has links)
Introduction: The objective of this experimental research was to evaluate the slot’s vertical dimension and profile of four different 0.018″ self-ligating brackets and to identify the level of tolerance accepted by manufacturers during the fabrication process. It was then possible to calculate and compare the torque play of those brackets using the measured values and the nominal values.
Material and Methods: Twenty-five 0.018″ self-ligating brackets of upper left central incisors from the following manufacturers, Speed® (Strite Industries, Cambridge, Ontario, Canada), InOvationR® (GAC, Bohemia, NY, USA), CarriereLX® (Ortho Organizers, Carlsbad, CA, USA) and SmartClip® (3M Unitek, Monrovia, CA, USA), were evaluated using electron microscopy with 150X images. The height of each bracket was measured at every 100 microns of depth from the lingual wall at five different levels. A Student T test was then used to compare our results with the manufacturer’s stated value of 0.018″. To determine if there was a significant difference between the four manufacturers, analysis of variance (ANOVA) was performed at the significance level of p<0.05. The torque play was then calculated using geometrical formulas.
Results: On average, Speed brackets were oversized by 2.7%[MV 0.0185″ (SD:0.002)], InOvationR by 3.7% [MV 0.0187″ (SD:0.002)], CarriereLX by 3.2% [MV 0.0186″ (SD:0.002)] and SmartClipSL by 5.0% [MV 0.0189″ (SD:0.002)]. The height of all brackets was significantly higher than the nominal value of 0.018″ (p<0.001). The slot of SmartClip brackets was significantly larger than those of the other three manufacturers (p<0.001). None of the brackets studied had parallel gingival and occlusal walls; some were convergent and others divergent. These variations can induce a torque play up to 4.5 degrees with a 0.017″x0.025″ wire and 8.0 degrees with a 0.016″x0.022″ wire.
Conclusion: All studied brackets were oversized. None of the brackets studied had parallel gingival and occlusal walls and there was no standard between manufacturers for the geometry of their slots. These variations can cause a slight increase of the torque play between the wire and the bracket compared with the nominal value. / Introduction : Cette recherche a été une étude expérimentale conduite en laboratoire visant à évaluer la dimension verticale ainsi que la géométrie de la lumière de différents boîtiers auto-ligaturants populaires de grandeur 0,018″. Par la suite, il a été possible de calculer mathématiquement la perte de torque engendrée par ces variations.
Matériel et méthode : Vingt-cinq boîtiers auto-ligaturants d’incisive centrale supérieure gauche de quatre différents manufacturiers, Speed® (Strite Industries, Cambridge, Ontario, Canada), InOvationR® (GAC, Bohemia, NY, USA), CarriereLX® (Ortho Organizers, Carlsbad, CA, USA) et SmartClip SL® (3M Unitek, Monrovia, CA, USA), ont été évalués en utilisant un microscope à balayage électronique à un grossissement de 150X. La hauteur de la lumière a été mesurée à tous les 100 microns de profondeur à cinq différents niveaux, permettant ainsi d’établir sa hauteur moyenne et d’évaluer le parallélisme de ses parois. Le test T de Student a été utilisé pour déterminer si ces valeurs étaient statistiquement significatives comparativement à la valeur de référence de 0,018″. Un test de variance (ANOVA), avec un seuil de signification p<0,05, a été utilisé pour comparer les boîtiers des différents manufacturiers entre eux. La perte de torque a, par la suite, été calculée théoriquement à l’aide de formules géométriques en fonction d’un fil donné.
Résultats : En moyenne, la lumière des boîtiers Speed était surdimensionnée de 2,7% [VM : 0,0185″ (DS : 0,002)], InOvationR de 3,7% [VM 0,0187″ (DS : 0,002)], CarriereLX de 3,2% [VM 0,0186″ (DS : 0,002)] et SmartClip SL de 5,0% [VM 0,0189″ (DS : 0,002)]. La hauteur moyenne des quatre types de boîtiers a démontré une différence statistiquement significative par rapport à la valeur de référence de 0,018″ (p<0,001). Il existe également une différence statistiquement significative entre la hauteur moyenne des boîtiers SmartClip et celle des trois autres manufacturiers (p<0,001). Aucun des boîtiers étudiés n’avait les parois gingivales et occlusales parallèles, certaines étaient divergentes, d’autres convergentes. Ces variations peuvent engendrer cliniquement une perte de torque jusqu’à 4,5 degrés avec un fil 0,017″x0,025″ et jusqu’à 8,0 degrés avec un fil 0,016″x0,022″.
Conclusion : La lumière de tous les boîtiers étudiés était légèrement surdimensionnée. La géométrie de la lumière variait d’un manufacturier à l’autre, certains boîtiers étaient convergents et d’autres divergents. Ces variations causées par les méthodes de fabrication engendrent une perte de torque supplémentaire par rapport à la valeur nominale.
|
172 |
Perception de la douleur durant le traitement orthodontique avec boîtiers auto-ligaturantsLabbé, Sandra 06 1900 (has links)
Introduction
Cette recherche constitue une étude clinique descriptive, visant à évaluer la douleur durant le traitement orthodontique avec boîtiers auto-ligaturants passifs et actifs.
Matériel et méthode
L'étude a été effectuée chez 39 patients (18 garçons, 21 filles), âge moyen 14 (entre 11 et 19 ans). Deux types de boîtiers auto-ligaturants ont été utilisés (SPEED n=20 et Damon n=19). Pour évaluer la douleur, un questionnaire a été élaboré par l'équipe de recherche. L’étude comportait 4 phases, c’est-à-dire l’évaluation de la douleur suite à l’insertion des 4 premiers fils orthodontiques du traitement de chaque patient (0.016 Supercable, 016 CuNiTi, 016X022 CuNiTi, 019X025 CuNiTi). Le même questionnaire était utilisé lors de chaque phase et le questionnaire comprenait 6 différents temps (T0: avant l’insertion du fil orthodontique, T1: immédiatement suite à l’insertion du fil, T2: 5h après l’insertion, T3: 24h après l’insertion, T4: 3 jours après l’insertion, T5: une semaine après l’insertion, T6: 4 semaines après l’insertion) suite à l’insertion de chaque fil. L’échelle visuelle analogue (EVA) et la version courte du questionnaire de Saint-Antoine ont été utilisés afin d’évaluer la douleur. Les données des EVA entre les groupes ont été comparées en utilisant le U test Mann-Whitney.
Résultats et discussion
Pour les deux premiers fils et pour tous les temps étudiés, il n’y avait pas de différence statistiquement significative entre les deux groupes (SPEED et Damon). Cependant, au moment de l’insertion (T0) du troisième fil (016X022 CuNiTi), parmi les patients ayant rapporté de la douleur (SPEED 47.1%, Damon 55.6%), le groupe Damon a rapporté une douleur significativement plus élevée que le groupe SPEED (p=0.018), (EVA moyenne SPEED=14.14±8.55, Damon=33.85±19.64). Trois jours après l’insertion du troisième fil, toujours parmi les patients ayant rapporté de la douleur (SPEED 23.5%, Damon 33.4%), la douleur était significativement plus élevée chez le groupe Damon que chez le groupe SPEED (p=0.008), (EVA moyenne SPEED=8.74±4.87, Damon=25.15±9.69). La plupart des analgésiques ont été pris suite à la pose du premier fil au temps T2 (5h) et T3 (24h). Il n’y avait pas de différence statistiquement significative entre les groupes en ce qui a trait au nombre de patients qui prenaient des analgésiques. La douleur n’a pas affecté le style de vie pour la grande majorité des patients. Les mots descriptifs sensoriels « tiraillement », « étau » et « élancement » et le mot affectif « énervant » étaient le plus souvent utilisés.
Conclusion
Les patients du groupe Damon ont ressenti significativement plus de douleur que les patients du groupe SPEED à l’insertion du troisième fil et trois jours suite à l’insertion. Plus de patients ont pris des médicaments pour la douleur avec le premier fil et le style de vie n’était pas affecté pour une majorité de patients. « Tiraillement », « étau », « élancement » et « énervant » étaient les mots descriptifs les plus utilisés par les patients pour décrire leur douleur. / Introduction
This research is a descriptive clinical study designed to assess pain during orthodontic treatment with self-ligating brackets.
Materials and methods
This study was comprised of 39 patients (18 male, 21 female), mean age of 14 (range 11 to 19 yo). Two types of self-ligating brackets (SPEED n=20 and Damon n=19) were used. Pain was evaluated with a questionnaire developed by the research team. The study was divided into 4 phases. Pain was evaluated for 4 weeks following the insertion of the first 4 orthodontic wires for each patient (0.016 Supercable, 016 CuNiTi, 016X022 CuNiTi, 019X025 CuNiTi). The same questionnaire was used during each phase and included 6 different time-points following the insertion of each wire (T0: before insertion of orthodontic wire, T1: immediately after the insertion of the wire, T2: 5h after insertion, T3: 24h after insertion, T4: 3 days after insertion, T5: 1 week after insertion, T6: 4 weeks after insertion). The visual analogue scale (VAS) and the short version of Saint-Antoine’s questionnaire were used to evaluate the pain. VAS ratings between groups were compared using the Mann-Whitney U test.
Results and Discussion
For the first two wires and for all the different time points, there was no statistical difference between both groups (SPEED and Damon). However, at the insertion (T0) of the third wire (016X022 CuNiTi), among patients that reported pain (SPEED 47.1%, Damon 55.6%), Damon caused statistically significantly more pain than SPEED (p=0.018), (VAS mean SPEED=14.14±8.55, Damon=33.85±19.64). Three days after the insertion (T4) of the third wire, among the patients that reported pain (SPEED 23.5%, Damon 33.4%), the pain was statistically significantly higher with Damon than SPEED (p=0.008), (VAS mean SPEED=8.74±4.87, Damon=25.15±9.69). The most frequent use of pain medication occured with the first wire, at time-points T2 (5h) and T3 (24h). There was no statistical difference among the groups in terms of the number of patients taking medication. For the large majority of patients, the pain did not affect their life-style. The most frequently used sensorial words used by the patients to describe their pain were « pulling » (tiraillement), « cramping » (étau), « throbbing» (élancement). The most frequently used affective word was « annoying » (énervant).
Conclusion
The perception of pain for patients with Damon brackets was significantly higher than for those with the SPEED brackets at the insertion of the third wire and three days after placement of the third wire. More patients took pain médication with the first wire and the majority of patients did not report a change in their quality of life. « Pulling » (tiraillement), « cramping » (étau), « throbbing» (élancement) and « annoying » (énervant) were the words most frequently used by the patients to describe their pain.
|
173 |
ESTRATÉGIAS PARA A REMOÇÃO DE PIGMENTOS DEPOSITADOS SOBRE BRÁQUETES ESTÉTICOS / STRATEGIES FOR REMOVAL OF PIGMENTS DEPOSITED ON AESTHETIC BRACKETSOtero, Laura Meireles 25 July 2016 (has links)
The aim of this study was to evaluate the efficiency of cleaning methods in removing pigment deposited on aesthetic brackets, after immersion in coffee. We selected 160 premolar brackets (80 monocrystalline and polycrystalline 80). The brackets were fixed on a glass blade and soon, thereafter, color measurement was performed using a spectrophotometer (T0). For each means of immersion, 80 brackets were selected (40 for each type of ceramic). Soon after staining (30 days of immersion), new color measurements were made (T1). Subsequently, the specimens were divided randomly into four groups for brushing, bleaching, blasting with sodium bicarbonate jet and sodium bicarbonate jet followed by bleaching. New color measurements were made after each cleaning method was used (T2). The color change of the brackets was evaluated according to two formulae, i.e., CIELAB and CIEDE2000. The differences between the average ΔE according to treatment, bracket, and solution were evaluated by linear regression analysis. The greatest staining was caused by coffee. The crystalline structure did not influence the color change. The methods with lower averages of ΔE for coffee were sodium bicarbonate jet followed by bleaching and bleaching, followed by the group that received brushing and sodium bicarbonate jet (both CIELAB as to CIEDE2000). The CIEDE2000 formula was more sensitive in detecting non-acceptable and perceptible differences in color when compared with the CIELAB formula. It was concluded that the most effective methods to remove pigment deposited on aesthetic brackets are sodium bicarbonate jet followed by bleaching and bleaching alone. / O objetivo desse estudo foi avaliar a eficiência dos métodos de limpeza na remoção de pigmentos depositados sobre bráquetes estéticos, após imersão em café. Foram selecionados 160 bráquetes (80 monocristalinos e 80 policristalinos) de pré-molares superiores. Os bráquetes foram fixados em uma lâmina de vidro e logo depois a mensuração de cor foi realizada com um espectrofotômetro (T0). Cada meio de imersão (café ou saliva) continha 80 bráquetes (40 para cada tipo de cerâmica). Logo após a coloração (30 dias de imersão) novas aferições foram feitas (T1). Posteriormente, os espécimes foram divididos randomicamente em 4 grupos: Grupo 1 Escovação; Grupo 2 Clareamento; Grupo 3 Jateamento com bicarbonato de sódio; Grupo 4 Jateamento com bicarbonato de sódio seguido de Clareamento. Novas aferições foram feitas depois de cada método de limpeza (T2). A variação da cor dos bráquetes foi avaliada de acordo com 2 fórmulas: CIELAB E CIEDE2000. As diferenças entre as médias de ΔE de acordo com o tratamento, braquete e solução foram avaliadas através de análise de regressão linear. O café promoveu maior manchamento. A estrutura cristalina não influenciou na alteração de cor. Os métodos com menores médias de ΔE, no café, foram o jateamento com posterior clareamento e o clareamento sozinho, seguido dos grupos que receberam jateamento e escovação (tanto para CIELAB quanto para CIEDE2000). A fórmula CIEDE2000 foi mais sensível em detectar diferenças de cor não-aceitáveis e perceptíveis quando comparado à fórmula CIELAB. Conclui-se que os métodos mais eficazes na remoção de pigmentos depositados sobre bráquetes estéticos são o jateamento com bicarbonato de sódio com posterior clareamento e o clareamento sozinho.
|
174 |
"Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT" / Study of the effects of active and passive lacebacks in the biomechanics of the leveling phase using the MBT techniqueRicardo Cesar Moresca 09 June 2006 (has links)
O objetivo deste trabalho foi estudar os efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento, utilizando-se a técnica MBT. A amostra foi constituída de 29 sujeitos de pesquisa (22 do gênero feminino e 7 do gênero masculino), brasileiros, leucodermas e pardos, portadores de má oclusão de Classe I e com idade média de 15 anos e 5 meses. O tratamento ortodôntico foi planejado com as extrações dos primeiros pré-molares e, durante a fase estudada, foram empregados apenas fios de aço inoxidável (0.014, 0.016, 0.018, 0.020 e 0.019 x 0.025). Os recursos de ancoragem utilizados para os arcos dentários superior e inferior foram, respectivamente, o aparelho extrabucal tipo IHG e o arco lingual fixo. De acordo com a indicação dos lacebacks, a amostra foi dividida em quatro grupos: grupo I 14 sujeitos que utilizaram lacebacks ativos no arco dentário superior; grupo II 9 sujeitos que utilizaram lacebacks passivos no arco dentário superior; grupo III 19 sujeitos que utilizaram lacebacks ativos no arco dentário inferior e grupo IV 10 sujeitos que utilizaram lacebacks passivos no arco dentário inferior. Para cada indivíduo da amostra foram tomadas duas telerradiografias laterais, uma ao início e outra ao término da fase de nivelamento, com um intervalo médio de 21 meses. Os dados foram coletados utilizando-se o método cefalométrico computadorizado. Para a análise de erros, o método cefalométrico foi repetido em todos os sujeitos da amostra, pelo mesmo operador, com um intervalo mínimo de 15 dias entre as medidas. Os resultados indicaram que as variações observadas foram compatíveis com as estimativas de erros operacionais em estudos cefalométricos. Após a análise estatística e a interpretação dos resultados, verificou-se que, no grupo I, apenas a coroa do primeiro molar superior sofreu um movimento mesial e que tanto a coroa como a raiz do incisivo central superior apresentaram um movimento em direção lingual. No entanto, as inclinações destes dentes não foram alteradas. No grupo II, o primeiro molar superior se manteve estável e somente a coroa do incisivo central superior se movimentou em direção lingual, produzindo uma rotação horária deste dente. No grupo III, observou-se uma mesialização, tanto da coroa como da raiz, e extrusão do primeiro molar inferior, enquanto a posição do incisivo central inferior permaneceu inalterada. As inclinações destes dentes também não foram alteradas. No grupo IV, verificou-se que nem o primeiro molar inferior nem o incisivo central inferior apresentaram variações no sentido ântero-posterior. Verticalmente, houve extrusão apenas do primeiro molar inferior. / The purpose of this study was to evaluate the effects of active and passive lacebacks in the biomechanics of the leveling phase, using the MBT technique. The sample was composed of 29 Brazilian subjects (22 female and 7 male), Caucasian, with Class I malocclusion and mean age of 15 years and 5 months. The orthodontic treatment was planned with the extraction of the first premolars, and the leveling phase was performed with stainless steel wire only (0.014, 0.016, 0.018, 0.020 e 0.019 x 0.025). The anchorage control devices used in the upper and lower arches were, respectively, the IHG extraoral appliance and the fixed lingual arch. According to the type of laceback prescription, the sample was divided into four groups: group I 14 subjects in which active lacebacks were used in the upper arch; group II 9 subjects in which passive lacebacks were used in the upper arch; group III 19 subjects in which active lacebacks were used in the lower arch; group IV 10 subjects in which passive lacebacks were used in the lower arch. For each subject of the sample two lateral cephalometric radiographs were taken: one at the beginning and another at the end of the leveling phase, with a mean interval of 21 months. The data were collected using the resources of computerized cephalometry. To perform the analysis of errors, the cephalometric method was repeated in all subjects of the sample, by the same operator, with a minimum interval of 15 days between the measurements. The results revealed that the observed variations were compatible with the estimates of operational errors in cephalometric studies. After statistical analysis and interpretation of the results, it was observed that in group I, only the crown of the upper first molar presented a mesial movement. As to the upper central incisor, both the crown and the root presented a lingual movement. However, the inclination of these teeth was not affected. In group II, the upper first molar remained stable and only the crown of the upper central incisor moved lingually, leading to a clockwise rotation of this tooth. In group III, a mesial movement of both the crown and the root of the lower first molar was observed, along with its extrusion, whereas the position of the lower central incisor remained unchanged. The inclination of these teeth was not affected either. In group IV, it was observed that neither the lower first molar nor the lower central incisor experienced variations in the anteroposterior sense. Vertically, there only was extrusion of the lower first molar.
|
175 |
Protótipo de ponteira acoplada aos aparelhos fotopolimerizadores para colagem de bráquetes e acessórios ortodônticosMota Júnior, Sergio Luiz 14 February 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-18T14:18:46Z
No. of bitstreams: 1
sergioluizmotajunior.pdf: 65970440 bytes, checksum: b08afa740679beb93b85550945b417d2 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-01T18:47:10Z (GMT) No. of bitstreams: 1
sergioluizmotajunior.pdf: 65970440 bytes, checksum: b08afa740679beb93b85550945b417d2 (MD5) / Made available in DSpace on 2016-07-01T18:47:10Z (GMT). No. of bitstreams: 1
sergioluizmotajunior.pdf: 65970440 bytes, checksum: b08afa740679beb93b85550945b417d2 (MD5)
Previous issue date: 2012-02-14 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi o desenvolvimento de uma nova ponteira para ser
acoplada aos aparelhos fotopolimerizadores utilizados para colagem de bráquetes e
acessórios ortodônticos, e teste da efetividade da mesma em ensaio mecânico in
vitro. A ponteira é espelhada na superfície interna e baseia-se em conceitos físicos
de refração e reflexão de luz. Apresenta como principal vantagem, a redução do
tempo clínico necessário para o procedimento de colagem, reduzindo, dessa forma,
a possibilidade de contaminação durante o processo. Através do ensaio de
resistência mecânica ao cisalhamento e da determinação do Indice Remanescênte
de Adesivo (IRA), testou-se a ponteira em uma amostra composta por 120 corpos de
prova, sendo a mesma dividida em 2 grupos. No grupo 1 foi utilizado aparelho
fotopolimerizador de fonte de luz halógena e no grupo 2 foi utilizado fonte de LED.
Cada grupo foi subdividido. Nos subgrupos H1 e L1 utilizou-se a ponteira
convencional dos respectivos instrumentos. Nos subgrupos H2 e L2 a colagem foi
feita utilizando-se a ponteira desenvolvida. Os valores dos testes de cisalhamento e
IRA para os subgrupos foram comparados entre si. Os resultados mostraram que
não houve diferença estatisticamente significante, tanto para os ensaios de
resistência ao cisalhamento (p>0,05), quanto para o IRA (p>0,05) entre os
subgrupos. Conclui-se que 1 - os testes de ensaios mecânicos, assim como a
análise do IRA mostraram que a nova ponteira desenvolvida, cumpriu os requisitos
necessários à colagem dos acessórios ortodônticos; 2 – o tempo de colagem foi
reduzido pela metade, sendo necessária uma só incidência. / The porpose of the present study was the development of a new device to be
coupled to light-curing units for bonding orthodontic brackets and accessories and
test of its efficacy in “in vitro” mechanical trial. The inner surface of the device is
mirrored and is based on physical concepts of light refraction and reflection. The
main advantage of such device is the reduced clinical time needed for bonding and
the lesser possibility of contamination during the process. 120 bodies of proof were
used for testing the shear bond strength of brackets bonded with the device. The
Adhesive Remnant Index (ARI) was also determined. The sample was divided into 2
groups. In group 1 a halogen light-curing unit was used and in group 2 a led lightcuring
unit was used. Each group was then subdivided. In subgroups H1 and L1, a
conventional light guide rod was used. In subgroups H2 and L2 bonding was
performed with the mirrored device coupled to the tip of the guide light rod. The
values obtained for the shear bond strength and the ARI in the subgroups were
compared. Results showed that there was no statistically significant difference for the
shear strength (p>0,05) and the ARI (p>0,05) between the subgroups. Conclusions
are that 1 - The tests of mechanical trials and the ARI analysis showed that the new
device fulfilled the requisites for bonding orthodontic accessories; 2 - time for bonding
was reduced to half, being necessary only one light exposure.
|
176 |
Avaliação das cargas de adesão e das superfícies do esmalte dentário após a remoção de bráquetes ortodônticos cerâmicos e metálicos: uma visão por microscopia eletrônica de varreduraRocha, José Maurício da 03 March 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-07-24T13:54:41Z
No. of bitstreams: 1
josemauriciodarocha.pdf: 1043351 bytes, checksum: cf01ad4dea7870b0a189a72005b608f0 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-09T13:46:41Z (GMT) No. of bitstreams: 1
josemauriciodarocha.pdf: 1043351 bytes, checksum: cf01ad4dea7870b0a189a72005b608f0 (MD5) / Made available in DSpace on 2017-08-09T13:46:41Z (GMT). No. of bitstreams: 1
josemauriciodarocha.pdf: 1043351 bytes, checksum: cf01ad4dea7870b0a189a72005b608f0 (MD5)
Previous issue date: 2010-03-03 / Este estudo objetivou avaliar, in vitro, a resistência ao cisalhamento apresentada por três marcas comerciais de bráquetes ortodônticos cerâmicos policristalinos e uma marca de bráquete metálico, todos com retenção mecânica, verificando os índices de resina remanescentes após os ensaios, e analisar, através da microscopia eletrônica de varredura, as topografias superficiais do esmalte pós-descolagem, detectando o desprendimento de partículas minerais do esmalte após a remoção dos bráquetes. Foram utilizados 60 incisivos inferiores bovinos recém-extraídos. Os bráquetes cerâmicos policristalinos (Allure®, InVu® e Clarity®) e metálico (Geneus®) foram colados utilizando-se o adesivo Transbond XT®. Para os resultados referentes ao cisalhamento, utilizou-se o teste de Kruskal-Wallis, com nível de significância de 5%. O teste de Mann-Whtiney foi utilizado para comparar os diferentes tipos de bráquetes aos pares, quanto aos índices de resina remanescentes. Para a análise dos resultados referentes às composições químicas do esmalte aplicou-se o teste de Brown-Forsythe com significância estatística ao nível de 5%. As comparações entre os grupos foram realizadas utilizando os testes Post Hoc de Games-Hoewell. Não foram observadas diferenças estatisticamente significativas, quanto as cargas de cisalhamento, durante a descolagem dos bráquetes. Em relação ao IRA, quando comparados aos pares, foi possível observar diferenças estatísticas entre os bráquetes Clarity® e InVu® (p = 0,002), Allure® e InVu® (p = 0,006) e, Clarity® e Geneus® (p = 0,0022). Foi confirmada a prevalência do escore “4”, com um percentual de 40,4%. Em relação à topografia superficial do esmalte, o Geneus® foi o único que não apresentou perda de tecido superficial. O Clarity® foi o mais afetado em relação à topografia superficial e ao desprendimento de partículas minerais do esmalte (íons Ca). O InVu® e o Clarity® apresentaram fraturas coesivas de 33,3% de suas amostras e o Allure® de 50%, sendo o que mais apresentou fraturas durante a remoção. / This study aimed at evaluating, in vitro, the shear bond strength shown by three different brands of polycrystalline ceramic orthodontic brackets and a brand of metallic orthodontic bracket, all with mechanical retention, by verifying the adhesive remnant index after trials, and to analyze, by means of scanning electronic microscopy, the superficial enamel topographies after debonding, detecting the release of mineral particles of enamel after bracket removal. Sixty recently extracted mandibular bovine incisors were used in this study. Polycrystalline ceramic brackets (Allure®, InVu®, and Clarity®), and metallic brackets (Geneus®) were bonded with Transbond XT®. For the results concerning the shear bond strength the KruskalWallis test was applied with a significance level of 5%. The Mann Whitney test was performed to compare the different types of brackets by pair, in relation to the adhesive remnant. For the analysis of the results concerning the chemical composition of the enamel the Brown-Forsythe test was applied with a significance level of 5%. Comparisons between the groups were analyzed using the GamesHowell Post Hoc test. No statistically significant differences were observed in relation to shear loads during bracket debonding. In relation to ARI, when the pairs are compared, it was possible to observe statistically significant differences between Clarity and InVu brackets (p = 0,002), Allure and InVu (p = 0.006), and Clarity and Geneus (p = 0.0022). The prevalence of score “4” was confirmed with a percentile of 40.4%. In relation to the superficial enamel topography, the Geneus® bracket was the only one which did not show loss of superficial tissue. Clarity® brackets was the most affected in relation to superficial topography and to the release of mineral particles of enamel (Ca ions). InVu® and Clarity® brackets showed cohesive fractures in 33.3% of their samples and the Allure® in 50%, the latter being the one that presented most fractures during removal.
|
177 |
Efeito de cobertura antiaderente no acúmulo de biofilme em dispositivos ortodônticos / Effect of accumulation of coverage nonstick biofilm on orthodontic bracketsOliveira, Adauê Siegert de 01 June 2012 (has links)
Made available in DSpace on 2014-08-20T14:30:05Z (GMT). No. of bitstreams: 1
tese_Adaue_banca.pdf: 296840 bytes, checksum: 0cd98d8b2ca7a1306c82e4b8319d9e71 (MD5)
Previous issue date: 2012-06-01 / The use of orthodontic devices has been associated with an increase in dental biofilm retention. In this study, the effect of hydrophobic coatings, based on (fluorinated or not) organo-silanes, on the reduction of the contact angle and early biofilm retention in orthodontic devices was tested. Two different types of hydrophobic were tested: hydrophobic solution 1 (SH1), obtained by dilution of 2.5% of hexadecyl-triethoxy-silane in ethanol, and hydrophobic solution 2 (SH2), composed of 2.5% of perfluorodecyl-triethoxy-silane diluted in dimethyl sulfoxide. The solutions were applied in ceramic and stainless steel substrates and, via sol-gel process and crosslinking, siloxane networks were formed on the surface of the devices. The effect of the coatings was evaluated in two stages. In the first stage, aiming the characterization of the surface, the water contact angle was analyzed. Stainless steel and polycrystalline alumina plates were prepared, previously applying or not alumina sandblasting as surface treatment. A significant increase in contact angle was observed with the application of both hydrophobic solutions in both substrates, with the sandblasting allowing formation of super-hydrophobic surface in the ceramic substrate (contact angle up to 155o), while hydrophobic surfaces were obtained in the steel substrate (contact angle up to 123o). In the second phase, the effect of the hydrophobic coating on the biofilm retention in orthodontic brackets was evaluated using a microscosm model. Orthodontic brackets were previously prepared according to the surface treatments that showed the best results in the phase 1 (SH1 for steel, SH2 for ceramic). The effect of the coatings on the biofilm formation was evaluated in periods of 12h and 24h (controls: uncoated substrates and sandblasted substrates). The results showed that the hydrophobic coatings did not result in significant effect in biofilm retention for the time 12h, whereas all coating treatments significantly reduced the biofilm retention in the metal and ceramic brackets compared with the control groups. A significant exponential reduction in biofilm retention at 24h was associated with the increase in contact angle. It can be concluded that application of (super)-hydrophobic crosslinked coatings via sol-gel process on the surface of orthodontic metal and ceramic brackets reduced the surface wetting of the surfaces in contact with water and had a significant effect on the retention of dental biofilm after 24h / O uso de dispositivos ortodônticos tem sido associado ao aumento da retenção de biofilme dentário. Neste estudo, foi testado o efeito de coberturas hidrófobas,baseadas em organo-silanos (flourados ou não), no aumento do ângulo de contato e redução de acúmulo de biofilme inicial em dispositivos ortodônticos. Dois tipos diferentes de soluções hidrófobas foram testadas: solução hidrófoba 1 (SH1), obtida
pela diluição de 2,5% de hexadecil-trietóxi-silano em etanol, e solução hidrófoba 2 (SH2), composta por 2,5% de perfluorodecil-trietóxi-silano diluído em dimetilsulfóxido. As soluções foram aplicadas em substratos cerâmico e de aço inox e, via processo sol-gel e reticulação, foram formadas redes siloxanas na superfície dos dispositivos. O efeito das coberturas foi avaliado em duas etapas. Na primeira
etapa, buscando a caracterização da superfície, foi analisado o ângulo de contato com água. Placas de aço inox e alumina policristalina foram preparadas, aplicando ou não jateamento prévio das superfícies com partículas de alumina. Foi observado aumento significativo do ângulo de contato com a aplicação das duas soluções hidrófobas em ambos substratos, sendo que o jateamento do substrato propiciou a
formação de superfície superhidrófoba no substrato cerâmico (ângulo de contato de até 155o), enquanto superfícies hidrófobas foram obtidas no substrato aço (ângulo de contato até 123o). Na segunda fase do trabalho, avaliou-se o efeito da cobertura no acúmulo de biofilme em braquetes ortodônticos, através de modelo de microcosmos. Braquetes ortodônticos foram previamente preparados conforme os tratamentos de superfície que apresentaram melhores resultados na primeira fase (SH1 para aço, SH2 para cerâmica). Foi avaliado o efeito da cobertura na formação de biofilme em períodos de 12h e 24h (controles: substratos não-recobertos e substratos jateados). Os resultados mostraram que as coberturas hidrófobas não resultaram em efeito significativo no acúmulo de biofilme no tempo 12h, entretanto todos os tratamentos de cobertura reduziram de forma significativa o acúmulo de
biofilme sobre os braquetes metálicos e cerâmicos comparados aos grupos controle no período 24h. Foi observada relação de redução exponencial significativa entre ângulo de contato e acúmulo de biofilme para o tempo 24h. Dessa forma, conclui-se
que a aplicação de coberturas (super)-hidrófobas reticuladas via processo sol-gel na superfície de dispositivos ortodônticos metálicos e cerâmicos reduziu o molhamento das superfícies em contato com a água e teve efeito significativo na retenção de biofilme bucal sobre esses dispositivos após 24h
|
178 |
Influência de bráquetes e tipos de ligadura no acúmulo microbiano e na desmineralização do esmalte adjacente a dispositivos ortodônticos / Influence of brackets and types of ligation in plaque accumulation and on enamel demineralization adjacent to orthodontic appliancesPacce, Marcos Antonio 17 December 2011 (has links)
Made available in DSpace on 2014-08-20T14:30:12Z (GMT). No. of bitstreams: 1
tese _Marcos_Antonio_Pacce.pdf: 838653 bytes, checksum: 3b5b150df1ebc16ec76a6a42a2e0c8a5 (MD5)
Previous issue date: 2011-12-17 / The orthodontic treatment has been related to caries lesions development, since the devices used are biofilm retentive. This thesis aimed to evaluate the effect of ligation type and type of orthodontic bracket in the mineral loss and biofilm accumulation to these devices. To accomplish this goal, three studies were conducted. The first study consisted in a systematic literature review, where electronic databases (PubMed, Embase, Cochrane Central Register of Controlled Trials, ISI Web of Knowledge, TRIP, Scopus, and SciELO) were searched up to July 2011. Clinical trials or in situ studies that assessed the effect of types of brackets or ligatures on biofilm accumulation and/or enamel demineralization were selected. Non-controlled studies, in vitro studies, or studies not reporting on the established outcomes were excluded. The second study assessed the enamel demineralization around six types of brackets/archwire ligation combinations. In that study, microcosm plaque biofilms were grown in 24-well microplates on enamel discs for 14 days in artificial saliva. Growth condition comprised cariogenic challenge. The groups (n=10 per group) were: self-ligating brackets (SL); conventional brackets ligated with stainless steel wires (CW); conventional brackets (CE), brackets with hooks (HE), ceramic brackets (KE), and composite brackets (RE), all the four ligated with elastomeric rings. The biofilm formed around the brackets was collected and dry-weighted and the mineral loss around the brackets was determined by cross-sectional microhardness. The third study evaluated in situ the combinated effect of types of brackets and archwire ligation on enamel demineralization, on the accumulation and on microbiological composition of dental plaque. The study design was a modified in situ model, randomized, double-blind and split-mouth. Volunteers (n=17) wore palatal removable appliances containing enamel discs with bonded orthodontic brackets during 14 days. To provide cariogenic challenge, 20% sucrose solution was dripped 8x/day onto each disc. The four conditions under study were: CE; CW; HE; and SL. The biofilm formed around the brackets was collected for microbiological analyses and the mineral loss was determined by cross-sectional microhardness measurement. The systematic review results showed contradictions among studies, and a great methodology variation among them. The reviewed papers did not allow any conclusion about the effect of types of brackets and ligatures on caries lesions and biofilm accumulation. No differences were observed in vitro or in situ regarding biofilm biomass (P>0.05), except for the HE group wich presented lower biofilm accumulation in vitro (P<0.05). Lower demineralization was observed associated to self-ligated brackets, and brackets with more complex design promote higher demineralization than self-ligated brackets. The ligature methods also affected demineralization, and elastomeric rings are more prone to promote caries lesions then steel wires / O tratamento ortodôntico é relacionado com o desenvolvimento de lesões de cárie, uma vez que o aparelho constitui-se em fator de retenção do biofilme. Este trabalho de tese teve como objetivo avaliar o efeito do tipo de ligadura e tipo de bráquete ortodôntico na perda mineral e no acúmulo de biofilme adjacente a estes dispositivos. Para cumprir esse objetivo, três estudos foram realizados. O primeiro estudo consistiu em numa revisão sistemática da literatura, onde bancos de dados eletrônicos (PubMed, Embase, Cochrane Central Register of Controlled Trials, ISI Web of Knowledge TRIP, Scopus e SciELO) foram pesquisados até julho de 2011. Ensaios clínicos ou estudos in situ que avaliaram o efeito de tipos de bráquetes ou ligaduras no acúmulo de biofilme e/ou a desmineralização do esmalte foram selecionados. Estudos não controlados, in vitro, ou que não apresentaram os desfechos procurados foram excluídos. O segundo estudo avaliou a desmineralização do esmalte em torno de seis tipos de combinações de bráquetes / tipos de ligadura. Biofilmes foram formados a partir de inóculos de saliva (microcosmos) e cultivados em microplacas de 24 poços sobre discos de esmalte por 14 dias em saliva artificial, sob desafio. Os grupos (n = 10 por grupo) foram: bráquetes autoligantes (AL); bráquetes convencionais ligados com amarrilhos de aço inoxidável (CA); bráquetes convencionais (CE), bráquetes com ganchos (GE), bráquetes de cerâmica (KE), e bráquetes de compósito (RE), todos os quatro ligados com anéis elastoméricos. O biofilme formado em torno dos bráquetes foi coletado e teve seu peso seco determinado (mg). A perdam mineral adjacente aos bráquetes foi avaliada por microdureza de secção longitudinal. O terceiro estudo avaliou in situ o efeito combinado de tipos de bráquetes e tipos de ligadura sobre a desmineralização do esmalte, o acúmulo de biofilme e a sua composição microbiana. O estudo teve um desenho experimental randomizado, duplo-cego e de boca dividida. Voluntários (n = 17) usaram placas palatais removíveis contendo discos de esmalte com bráquetes ortodônticos durante 14 dias. Para fornecer desafio cariogênico, solução de sacarose 20% foi gotejada 8x/dia em cada disco. As quatro condições em estudo foram: CE; CA; GE e AL. Os biofilmes formados em torno dos bráquetes foram coletados para análises microbiológicas e a perda mineral foi determinada pelo método descrito acima. Os resultados da revisão sistemática mostraram divergência entre os estudos, com muita variabilidade metodológica entre eles. Os artigos revisados não permitem chegar a uma conclusão sobre o papél dos tipos de bráquetes ou ligadura no desenvolvimento de lesões de cárie ou no acúmulo de biofilme. Não foram observadas diferenças in vitro ou in situ quanto a biomassa do biofilme (P> 0,05), exceto para o grupo GE, o qual apresentou menor acúmulo de biofilme in vitro (P<0,05). Menor desmineralização foi observada associada à bráquetes autoligantes (P< 0,05). Bráquetes com um desenho mais complexo promovem maior desmineralização do que os autoligantes (P< 0,05). Os métodos de ligadura também afetaram a desmineralização, e anéis elastoméricos promovem lesões de cárie do que amarrilhos de aço (P< 0,05).
|
179 |
Análise dentária tridimensional em pacientes biprotrusos submetidos a extrações de primeiros pré-molares /Cunha, Anderson Farias da January 2018 (has links)
Orientador: Luiz Gonzaga Gandini Júnior / Resumo: Objetivo: Avaliar as alterações dentárias em indivíduos biprotrusos submetidos a extração dos quatro primeiros pré-molares. Materiais e métodos: A amostra constituise de 50 pacientes adultos Classe I de Angle, biprotrusos, com apinhamento até 4mm por arco dentário e com necessidade de extração de quatro primeiros pré-molares, que foram randomizados em 2 técnicas de tratamento: a retração em massa (n = 25) e a retração em duas etapas (n = 25, cada paciente teve colado um braquete convencional ou autoligado em cada canino de forma aleatória). Foram usados modelos digitais obtidos antes, um, dois e três meses após o início da retração dos caninos, e após o fechamento dos espaços das extrações. Foram avaliados a inclinação, angulação e rotação dos caninos (durante a retração dos caninos), e a rotação dos primeiros molares superiores (na retração em massa ou duas etapas). Resultados: Nenhuma diferença foi encontrada entre a técnica de retração ou tipo de braquete. Conclusão: Conclui-se que não houve diferença na angulação, inclinação e rotação entre os braquetes convencionais ou autoligados, além disso a rotação dos molares foi similar na retração em massa e duas etapas. / Abstract: Objetive: To evaluate the dental changes in patients bimaxillary protrusion with firstpremolar extraction. Methods: Fifty adults patients Class I malocclusion, dentalprotrusion, arch length discrepancy bellow for 4mm, and need for first premolarextractions were randomized to 2 treatment techniques: en-mass retraction (n = 25)and two-steps retraction (n = 25, patients had either conventional or self-ligatingbrackets bonded to canines randomly). Digital models before, and one, two, threemonths after starting the canine retraction, and after the closing of space. Wereevaluated the canine inclination, angulation and rotation (canine retraction), androtation of the upper first molars (en-mass or two-steps retraction). Results: Nodifferences were found between retraction techniques or the type of bracket.Conclusions: Angulation, inclination and rotation showed no diferences betweenconventional or self-ligating brackets, besides that the rotation molar was similar in enmassor two-steps retraction. / Mestre
|
180 |
Detecção de microrganismos cariogênicos em bráquetes metálicos, com ou sem utilização de agente antimicrobiano, pela técnica checkerboard DNA-DNA hybridization - Estudo in vivo / Detection of cariogenic microorganisms on metallic brackets in vivo, with or without use of an antimicrobial agent by the checkerboard DNA-DNA hybridization techniqueOlmedo, Lourdes Yanissely Garcia 20 May 2009 (has links)
O objetivo do presente estudo clínico randomizado foi avaliar in vivo, por meio da técnica de biologia molecular Checkerboard DNA-DNA Hybridization: 1) A contaminação de bráquetes metálicos por 4 espécies bacterianas de microrganismos cariogênicos (Streptococcus mutans, Streptococcus sobrinus, Lactobacillus casei e Lactobacillus acidophilus); e 2) A eficácia da utilização do gluconato de clorexidina a 0,12% (Periogard®) sob a forma de bochechos, sobre esses microrganismos. Participaram do estudo 39 pacientes de 11 a 33 anos de idade, em tratamento com aparelho ortodôntico fixo, nos quais foram colados 2 bráquetes metálicos novos, nos pré-molares. Os pacientes do Grupo Controle (n=20) foram orientados a fazer 2 bochechos semanais com solução placebo, durante 30 dias. Os pacientes do Grupo Experimental (n=19) foram orientados a fazer bochechos com solução à base de gluconato de clorexidina a 0,12% (Periogard®), da mesma forma que o grupo Controle. Decorridos 30 dias, os 2 bráquetes foram removidos de cada paciente e processados para detecção das 4 cepas bacterianas, pela técnica Checkerboard DNADNA Hybridization. Os resultados obtidos foram analisados por meio do teste nãoparamétrico de Kruskal-Wallis, utilizando o software SAS (Statistical Analysis System). O nível de significância adotado foi de 5%. De acordo com os resultados obtidos, observou-se que S. mutans, S. sobrinus, L. casei e L. acidophilus foram detectados em 100% das amostras dos bráquetes de ambos os grupos. No entanto, os bráquetes do grupo Controle encontravam-se mais densamente contaminados por S. mutans e S. sobrinus (p<0,01). No grupo Experimental, embora as quantidades de S. mutans, S. sobrinus, L. casei e L. acidophilus tenham sofrido redução numérica após o uso dos bochechos com solução de gluconato de clorexidina a 0,12%, a comparação com os valores observados no grupo Controle evidenciou diferença estatisticamente significante apenas para S. mutans (p=0,03). Concluiu-se que os bochechos com solução de gluconato de clorexidina a 0,12% podem ser úteis, na prática clínica, com a finalidade de reduzir os níveis de microrganismos cariogênicos, em pacientes portadores de aparelhos ortodônticos fixos. / The purpose of this randomized clinical study was to evaluate in vivo, by the checkerboard DNA-DNA hybridization biomolecular technique: 1) The contamination of metallic brackets by four cariogenic bacterial strains (Streptococcus mutans, Streptococcus sobrinus, Lactobacillus casei and Lactobacillus acidophilus); and 2) The efficacy of 0.12% chlorhexidine gluconate mouthrinses (Periogard®) against these microorganisms. Thirty-nine 11-33-year-old patients under treatment with fixed orthodontic appliances were enrolled in the study and had 2 new metallic brackets bonded to the premolars. For the patients of the control group (n=20), mouthrinses with a placebo solution were prescribed twice a week during 30 days. The patients randomized to the experimental group (n=19) were instructed to use a 0.12% chlorhexidine gluconate solution (Periogard®) as an oral rinse twice a week during 30 days, in the same way as in control group. After this period, the 2 brackets were removed from each patient and processed for detection of the 4 bacterial strains by checkerboard DNA-DNA hybridization. The obtained data were analyzed statistically by the non-parametric Kruskal-Wallis test using the SAS (Statistical Analysis System) software. A level of significance of 5% was set for all analysis. S. mutans, S. sobrinus, L. casei and L. acidophilus were detected in 100% of the samples from brackets of both groups. However, the brackets of the control group were more heavily contaminated by S. mutans and S. sobrinus (p<0.01). In the experimental group, although S. mutans, S. sobrinus, L. casei and L. acidophilus counts decreased after rinsing with the 0.12% chlorhexidine gluconate solution, the comparison with the values obtained in the control group showed statistically significant difference only for S. mutans (p=0.03). In conclusion, the use of 0.12% chlorhexidine gluconate mouthrinses can be useful in clinical practice to reduce the levels of cariogenic microorganisms in patients under treatment with fixed orthodontic appliances.
|
Page generated in 0.071 seconds